Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED STRUCTURAL CALCS - 21-00577 - Storage 1910 - Bldg 1
Author Name Author Email Author Phone No.: Cody Jones Cody.Jones@rexburg.org 208-372-2173 Description : Storage 1910 - Bldg 1 Address : 4550 S 3300 W Record Type : Madison County - Commercial Document Filename : Storage 1910- P53988 Calculations[10463].pdf Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Approved # 21-00577 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments 1 Stamp Cody Jones : Building Open 1 Approved - Building Inspector Madison County - Commercial Approval of plans does not constitute approval of variance from code Powered by TCPDF (www.tcpdf.org) Trachte Building Systems, Inc. Project Calculations Per 2018 International Building Code Brandon Roberts Thorton, ID TBS Plan Number: P53988 March 25, 2021 Table of Contents Buildings #1 and #2 Pages A1 – A8 Building #3 Pages B1 – B7 Buildings #4 and #5 (10ft Bay) Pages C1 – C7 Building #4 (20ft Bay) Pages D1 – D7 Prepared By Claire Z. Robinson Reviewed By P R O F E S S I O N A L E N G I N E E R L I C ENSED S T A T E O F I D A H O R OSS T . M O R I Ross T. Mori 2021.05.14 13:20:49-05'00' TRACHTE BUILDING SYSTEMS, INC. PROJECT CALCULATIONS CUSTOMER "Brandon Roberts"PREPARED_BY "Claire Z. Robinson" LOCATION "Thorton, ID"REVIEWED_BY PLAN_NUMBER "P53988" BUILDING "#1 and #2" CODEBODY "IBC 2018" BUILDING DESCRIPTION BAY WIDTH bay 10ftPURLIN BRIDGING PBridging "no" ROOF PITCH Rpitch 0.5 in ftBUILDING HEIGHT height 8ft 4inROOF MATERIAL Roof "SSR" BUILDING WIDTH width 20ftPURLIN SPACING P space 5ft ROOF ANGLE θ 2.39 degBUILDING LENGTH length 60ftINT. PARTITION PANEL Ptpanel "yes" ROOF TYPE Type "Lean-to"FLOOR TO FLOOR lower 0ftINT. LATERAL BRIDGING Bridge "no" RISK CATEGORY UseGroup "I"Use "I" or "II"FOUNDATION SLOPE Fndslope 0% SNOW LOAD SEISMIC LOAD P g 50psfGROUND SNOW LOAD ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE E snow "C"SNOW EXPOSURE CATEGORY BUILDING FRAME SYSTEM BFS "Light Frame Wall w/ Flat Strap Bracing" IS 0.8SNOW IMPORTANCE FACTOR SEISMIC SITE CLASS Siteclass "D" Ct 1.2THERMAL FACTOR SHORT PERIOD SPECTIAL ACC.S S 0.368 Exp "Partial"SNOW EXPOSURE 1 SECOND PERIOD SPECTRAL ACC.S 1 0.141 Lr 20psfROOF LIVE LOAD FLAT ROOF SNOW LOAD P f 34 psfSPECTRAL RESPONSE ACC.S DS 0.37 UNBALANCE SNOW LOAD P unbalanced 34 psfSPECTRAL RESPONCE ACC.S D1 0.21 SNOW LOAD USED IN DESIGN P S 34 psfRESPONSE FACTOR Response 4 RAIN SURCHARGE RainSurcharge 0 psfSEISMIC DESIGN CATEGORY SeismicDC "D" WIND LOAD SEISMIC RESPONSE COFFICIENT Cs 0.09WIND VELOCITY V ult 100mph V asd 77 mph WIND EXPOSURE CATEGORY E wind "C" EDGE STRIP WIDTH a3ftDEAD LOAD DR 3 psfCOMPONENTS AND CLADDING (Method 2)ROOF DEAD LOAD DP 3 psfENDWALL GIRT FEG 23 psfPARTITION DEAD LOAD DL 0 psfSIDEWALL GIRT FSG 22 psfADDITIONAL LONG. DEAD LOAD DT 0 psfPURLIN Fpurlin 21psfADDITIONAL TRANS, DEAD LOAD MAIN WIND FORCE (Method 2)BASE SHEAR LONGITUDINAL TRANSVERSE WALL SuctionandPressure()FW 16 psfSEISMIC V Ls 870lbV Ts 145lb ROOF FR 8 psfWIND V Lw 840lbV Tw 511lb ANCHOR INFORMATION EDGE DISTANCE EdgeDistance 3 P53988_#1,#2.xmcd A1 3/25/2021 CONCRETE STRENGTH Concrete 2500 ϕN 0.65Table 3 - ESR-3889 ϕVs 0.60Table 4 - ESR-3889 ϕVc 0.70Table 4 - ESR-3889 do_.375 0.375indo_.5 0.5innominal anchor diameter (table 1 ESR 3889) hef_.375 1.33inhef_.375_3 1.75inhef_.5_2.5 1.75inhef_.5_3.5 2.17ineffective embedment (table 1 ESR 3889) cac_.375 5.0incac_.375_3 6.3incac_.5_2.5 3.3incac_.5_3.5 5.9incritical edge distance (table 1 ESR 3889) ψcn 1.0modification factor for cracked and uncraked concrete (tabel 4 ESR 3889 kc 17effectiveness factor for cracked concrete (table 4 ESR 3889) Np 0kipcharacteristic pulout strength, cracked concrete (table 4 ESR 3889) le_.375 1.33inle_.375_3 1.75inle_.5_2.5 1.75inle_.5_3.5 2.17inload bearing length of anchor (table 4 ESR 3889) Nsa_.375 8.730kipNsa_.5 20.475kipsteel strength in tension (table 3 ESR 3889) V sa_.375 3.465kipV sa_.5 8.860kipsteel strength in shear (table 4 ESR 3889) Corner Anchor nc 1number of bolts at column ca1_c 2.75indistance between bolts from edge 2 s1_c 0indistance between bolts along edge 1 ca2_c 2.75indistance of bolts from edge 1 s2_c 0indistance between bolts along edge 2 eN_c 0indistance from resultant tension load to centroid of anchors in tension ev_c 0indistance from sultant shear load to centroid of anchors in shear Exterior Anchor ne 2number of bolts at column ca1_e 2.75indistance between bolts from edge 2 s1_e 0indistance between bolts along edge 1 ca2_e 100indistance of bolts from edge 1 s2_e 5indistance between bolts along edge 2 eN_e 0indistance from resultant tension load to centroid of anchors in tension ev_e 0indistance from sultant shear load to centroid of anchors in shear Interior Anchor ni 1number of bolts at column ca1_i 100indistance between bolts from edge 2 s1_i 0indistance between bolts along edge 1 ca2_i 100indistance of bolts from edge 1 s2_i 0indistance between bolts along edge 2 eN_i 0indistance from resultant tension load to centroid of anchors in tension ev_i 0indistance from sultant shear load to centroid of anchors in shear P53988_#1,#2.xmcd A2 3/25/2021 ANCHOR FORCE SUMMARY SHEAR UPLIFT WIND / LONGITUDINAL / INTERIOR V wil 0lbNwil 130lb WIND / LONGITUDINAL / EXTERIOR V wel 168lbNwel 415lb WIND / TRANSVERSE / INTERIOR V wit 57lbNwit 130lb WIND / TRANSVERSE / EXTERIOR V wet 170lbNwet 278lb SEISMIC / LONGITUDINAL / INTERIOR V sil 0lbNsil 280lb SEISMIC / LONGITUDINAL / EXTERIOR V sel 828lbNsel 550lb SEISMIC / TRANSVERSE / INTERIOR V sit 31lbNsit 280lb SEISMIC / TRANSVERSE / EXTERIOR V set 92lbNset 25lb ULTIMATE LOADS FOR ANCHORS Tension (Interior)Tension (Exterior)Shear (Interior)Shear (Exterior) TensionI 847.44lbTensionX 1316.03lbShearI 912.63lbShearX 1247.4lb Bolt Interatction Check Applied Uplift / Tension + Applied Shear / Shear < 1.2 Longitudinal Transverse Interior Anchors Wind Anchori_wl 0.15Wind Anchori_wt 0.22 Siesmic Anchori_sl 0Siesmic Anchori_st 0.03 Exterior Anchors Wind Anchore_wl 0.45Wind Anchore_wt 0.35 Siesmic Anchore_sl 1.08Siesmic Anchore_st 0.07 Cormer Anchors Wind Anchorc_wl 0.21Wind Anchorc_wt 0.21 Siesmic Anchorc_sl 0Siesmic Anchorc_st 0 ANCHOR Interior Anchori "3/8" x 2.5"" Exterior Anchore "3/8" x 2.5"" P53988_#1,#2.xmcd A3 3/25/2021 PANEL CHECK PANEL CAPACITY V all 53 plf LONGITUDINAL SHEAR PANEL REQUIRED PanelLengthL 16.42ft LONGITUDINALSHEAR PANEL PanelL 0 TRANSVERSE SHEAR PANEL REQUIRED PanelLengthT 9.64ft TRANSVERSE SHEAR PANEL PanelT 20ft LONGITUDINAL SHEAR WALL PanelCheckL "not ok"(IF PANEL CHECK IS "OK" NO STRAP BRACES REQUIRED FOR LATERAL FORCE RESISTING SYSTEM BUT STRAPS MAY BE REQUIRED FOR ANCHORING)TRANSVERSE SHEAR WALL PanelCheckT "ok" STRAP BRACES (IF REQUIRED) LONGITUDINAL StrapsL 2 TRANSVERSE StrapsT 0 Allowable Tension in Strap Ta 2470.06lbGAUGE OF STRAP Gage 16STRAP WIDTH ws 2in Longitudinal Strap Angle BraceangleL 39.81 deg Transverse Strap Angle BraceangleT 39.81 deg Longitudinal Tension on Strap TL if PanelCheckL "ok"=0 max V Ls VLw cos BraceangleL TL 1132.9lb Transverse Tension on Strap TT if PanelCheckT "ok"=0 max V Ts VTw cos BraceangleT TT 0lb (Note: Compression member to be designed seperately, see additional calculations. Compression memeber needed only when StrapsT > 0) P53988_#1,#2.xmcd A4 3/25/2021 INPUT VALUES PURLIN BRIDGING SPACING PurlinBridgeSpace 60 DEPTH OF PURLIN webP 77, 9, 11 or 12 JAMB SUPPORT StubPostJ "no"HEIGHT OF HORIZONTAL BRACING BridgeHeight 4.58ft Cbrace 3.06ftWIDTH OF INTERIOR COLUMN webI 3.5CORNER COLUMN UNBRACED LENGTH (y & t) SIDE WALL COLUMN webS 3.5ColumnNumberSW 2SIDEWALL GIRT webG webSGirtNumber 1 END WALL COLUMN webE 3.5ColumnNumberEW 2ENDWALL GIRT webGE webEEGirtNumber 1 END CLOSET COLUMN (JAMB)webEWC 3.5ColumnNumberEWC 1(Use either 3.5 or 5.5 for the width of Side Wall, End Wall or End Closet Columns)END CLOSET COLUMN (HDR)webEC 3.5ColumnNumberEC 1 STUB POST HEADER (L)webH 95.5", 9", 10" or 12"MembersHL 1 STUB POST HEADER (S)webHS 5.55.5", 9", 10" or 12"MembersHS 1 LOAD COMBINATIONS LC1 = D + MAX(S,Lr)EQUATION 16-10 LC2 = D + MAX(.75S,.75Lr)EQUATION 16-11 LC3 = D +MAX( .6W,.7E)EQUATION 16-12 LC4 = D + ..45W + MAX(.75S,.75Lr)EQUATION 16-13 LC5 = D + ..525E +.75S EQUATION 16-14 LC6 = .6D + MAX(.6W,.7E)EQUATION 16-15 EQUATION 16-16 PURLIN INFORMATION PURLIN LOADS UNIFORM LOAD END REACTION MOMENT LC1 wPurlin1 183 plfRPurlin1 915lbMPurlin1 2287lb ft LC4 wPurlin4 158 plfRPurlin4 789lbMPurlin4 1971lb ft LC6 wPurlin6 53plfRPurlin6 264lbMPurlin6 661lb ft LC6 wPurlin6e 74plfRPurlin6ea 317lbRPurlin6eb 274lbMPurlin6e 920lb ft PURLIN MemberPR "7 x 16ga, 50ksi Cee Purlin"IntPR 0.760 LxPR 118.5inLyPR 118.5inLtPR 118.5 inLyPR_neg 118.5 inLtPR_neg 118.5 in STUB POST HEADERS STUB POST HEADER LOADS REACTION MOMENT LC1 RH1 915lbMH1 4575lb ft LC4 RH4 789lbMH4 3943lb ft LC5 RH6 264lbMH6 1321lb ft MEMBER SIZES INTERACTION LENGTH STUB POST HEADERS MemberH "9 x 3.2 x 16ga 50 ksi Stub Header"IntH 0.992HeaderLength 10ft STUB POST HEADER BRACING LxH 120 inLyH 120 inLtH 120 in SMALL STUB POST HEADERS MemberHS "5.5 x 3.2 x 18ga 33 ksi Stub Header"IntHS 0.780SHLength 5ft SMALL STUB POST HEADER BRACING LxHS 60 inLyHS 60 inLtHS 60 in P53988_#1,#2.xmcd A5 3/25/2021 INTERIOR COLUMNS INTERIOR COLUMN LOADS AXIAL LOAD MOMENT LC1 P I1 1830lbMI1 0 LC3 P I3 390lbMI3 0 LC4 P I4 1590lbMI4 196.94lb ft(Moment due to 5 psf horizontal load) LC5 P I5 1441lbMI5 196.94lb ft MEMBER SIZES INTERACTION INTERIOR COLUMN MemberI "3.63 x 2 x 16ga, 50 ksi Interior Column"IntI 0.727 INTERIOR COLUMN BRACING LxI 103 inLyI 12 inLtI 103 in JAMBS JAMB LOADS AXIAL LOAD MOMENT LC1 P Jamb1 915lbNA LC3 P Jamb3a 405lbMJamb3a 158lb ft LC3 P Jamb3b 458lbNA LC4 P Jamb4 952lbMJamb4 118lb ft LC5 P Jamb5 993lbNA JAMB UNIFORM LOAD swjamb 121 plfwEWJamb 69 plf JAMB APPLIED MOMENT JambMoment 158lb ftEWJambMoment 89lb ft JAMB AXIAL LOAD P Jamb1 915lb JAMB MOMENT CAPACITY Mjambcap 971lb ft JAMB AXIAL CAPACITY P jambcap 5691lb JAMB CHECK JambCheck "ok"EWJambCheck "ok" MEMBER SIZES END WALL HEADER MOMENT CAPACTIY EWheadermomenallt 2922lb ft END WALL HEADER APPLIED MOMENT EWhedermomentapp 2287.5lb ft LARGE END WALL HEADER CHECK EWheader_check16 "16in_EW Header O.K." EWheader_check22 "22in_EW Header O.K." SIDE WALL COLUMNS SIDE WALL LOADS AXIAL SIDE WALL MOMENT LC1 P SW1 915lbMSW 0lbft LC3 P SW3 405lb LC4 P SW4 953lb MEMBER SIZES INTERACTION SIDE WALL COLUMN MemberSW "3.63 x 1.5 x 18ga 33 ksi Column"IntSW 0.335 SIDE WALL COLUMN BRACING LxS 110 inLyS 37 inLtS 37 in P53988_#1,#2.xmcd A6 3/25/2021 END WALL COLUMNS END WALL LOADS AXIAL LOAD UNIFORM LOAD MOMENT LC1 P EW1 915lbNA NA LC3 P EW3 405lbwEW3 48 plfMEW3 504lb ft LC4 P EW4 953lbwEW4 36 plfMEW4 378lb ft MEMBER SIZES INTERACTION END WALL COLUMN MemberEW "3.63 x 1.5 x 18ga 33 ksi Column"IntEW 0.833 END WALL COLUMN BRACING LxE 103 inLyE 43 inLtE 43 in GIRTS GIRT LOADS UNIFORM LOAD END REACTION MOMENT wGS 40 plfRGS 202lbMGS 506lb ftSIDE WALL GIRT IN MID ZONE wGSe 48 plfRGSe 240lbMGSe 601lb ftSIDE WALL GIRT IN END ZONE wGE 50 plfRGE 248lbMGE 155lb ftGIRT IN MID ZONE wGEe 60 plfRGEe 300lbMGEe 188lb ftGIRT IN END ZONE MEMBER SIZES INTERACTION SIDE WALL GIRT (MID)MemberGS "3.5 x 1.75 x 18ga 33 ksi Girt"IntGS 0.890 END WALL GIRT (END)MemberGE "3.5 x 1.75 x 18ga 33 ksi Girt"IntGE 0.278 SIDE WALL GIRT BRACING LtG 119 in END WALL GIRT BRACING LtGE 59 in STUDS STUD SPACING StudSpacing 16 in STUD LOADS UNIFORM LOAD MOMENT wStud 19 plfMStud 197lb ftSIDE WALL STUD IN MID ZONE wStude 23 plfMStude 242lb ftSIDE WALL STUD IN END ZONE MEMBER SIZES INTERACTION SIDE WALL STUD MemberStud "3.625 x 2 x 20ga 33 ksi Stud"IntStud 0.421 SIDE WALL STUB BRACING LxStud 110 inLyStud 37 inLtStud 37 in FOUNDATION INFORMATION INTERIOR COLUMN REACTIONS GRAVITY P down_interior 1830lbUPLIFT P up_int 100lb EXTERIOR COLUMN REACTIONS GRAVITY P down_exterior 953lbUPLIFT P up_ext 293lb ALLOWABLE BEARING PRESSURE BearingPressure 1500 psf SLAB THICKNESS Slab 5 in PAD WIDTH PadW "na" in PAD DEPTH PadD "na" in LxG 119 in LxGE 59 inLyGE 12 in LyG 12 in P53988_#1,#2.xmcd A7 3/25/2021 AERODYNAMIC SHADE ROOF STEP HEIGHT hr 2ft0in BUILDING SEPARATION separation 0 ftHORIZONTAL DIM. OF UPPER ROOF Wbu 230ft DRIFT PURLIN SPACING P space.d 5ft 0inHORIZONTAL DIM. OF LOWER ROOF Wbl 20ft DRIFT INFORMATION SNOW DENSITY Dsnow 20.5pcfMAXIMUM DRIFT HEIGHT hd3 0.36ft MAXIMUM DRIFT LOAD P m 41 psfMAXIMUM DRIFT WIDTH Wd3 2.89ft PURLIN LOADS (w/ DRIFT)REACTIONS MOMENTS LOAD COMBINATION 1 (FORMULA 16-10)RPurlin1da 963lbRPurlin1db 920lbMPurlin1d 27759lbin LOAD COMBINATION 3 (FORMULA 16-16)RPurlin3da 881lbRPurlin3db 848lbMPurlin3d 25562lbin MEMBER SIZES PURLIN MemberPRD "7 x 16ga, 50ksi Cee Purlin"IntPRD 0.697 LxPRD 118.5inLyPRD 118.5inLtPRD 118.5inLyPRD_neg 118.5inLtPRD_neg 118.5in STUB POST HEADER LOADS (w/ DRIFT)REACTION MOMENT LOAD COMBINATION 1 (FORMULA 16-10)RH1D 939lbMH1D 56348lbin LOAD COMBINATION 3 (FORMULA 16-13)RH3D 848lbMH3D 50891lbin MEMBER SIZES STUB POST HEADERS MemberHD "9 x 3.2 x 14ga 50 ksi Stub Header"IntHD 0.791HeaderLengthD 10ft LxHD 120inLyHD 120inLtHD 120in COLUMN LOADS (w/ DRIFT)INTERIOR EXTERIOR LOAD COMBINATION 1 (FORMULA 16-10)P I1D 1878lbP EW1D 963lb LOAD COMBINATION 3 (FORMULA 16-13)P I3D 1696lbP EW3D 881lb MEMBER SIZES INTERIOR COLUMN MemberID "3.5 x 2 x 18ga, 33 ksi Interior Column"IntID 0.945 LxID 103inLyID 12inLtID 103in END WALL COLUMN)MemberEWD "3.63 x 1.5 x 18ga 33 ksi Column"IntEWD 0.767 LxED 103inLyED 43 inLtED 43 in P53988_#1,#2.xmcd 3/25/2021 A8 TRACHTE BUILDING SYSTEMS, INC. PROJECT CALCULATIONS CUSTOMER "Brandon Roberts"PREPARED_BY "Claire Z. Robinson" LOCATION "Thorton, ID"REVIEWED_BY PLAN_NUMBER "P53988" BUILDING "#3" CODEBODY "IBC 2018" BUILDING DESCRIPTION BAY WIDTH bay 10ftPURLIN BRIDGING PBridging "no" ROOF PITCH Rpitch 0.5 in ftBUILDING HEIGHT height 10ft 4inROOF MATERIAL Roof "SSR" BUILDING WIDTH width 20ftPURLIN SPACING P space 5ft ROOF ANGLE θ 2.39 degBUILDING LENGTH length 230ftINT. PARTITION PANEL Ptpanel "yes" ROOF TYPE Type "Lean-to"FLOOR TO FLOOR lower 0ftINT. LATERAL BRIDGING Bridge "no" RISK CATEGORY UseGroup "I"Use "I" or "II"FOUNDATION SLOPE Fndslope 0% SNOW LOAD SEISMIC LOAD P g 50psfGROUND SNOW LOAD ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE E snow "C"SNOW EXPOSURE CATEGORY BUILDING FRAME SYSTEM BFS "Light Frame Wall w/ Flat Strap Bracing" IS 0.8SNOW IMPORTANCE FACTOR SEISMIC SITE CLASS Siteclass "D" Ct 1.2THERMAL FACTOR SHORT PERIOD SPECTIAL ACC.S S 0.368 Exp "Partial"SNOW EXPOSURE 1 SECOND PERIOD SPECTRAL ACC.S 1 0.141 Lr 20psfROOF LIVE LOAD FLAT ROOF SNOW LOAD P f 34 psfSPECTRAL RESPONSE ACC.S DS 0.37 UNBALANCE SNOW LOAD P unbalanced 34 psfSPECTRAL RESPONCE ACC.S D1 0.21 SNOW LOAD USED IN DESIGN P S 34 psfRESPONSE FACTOR Response 4 RAIN SURCHARGE RainSurcharge 0 psfSEISMIC DESIGN CATEGORY SeismicDC "D" WIND LOAD SEISMIC RESPONSE COFFICIENT Cs 0.09WIND VELOCITY V ult 100mph V asd 77 mph WIND EXPOSURE CATEGORY E wind "C" EDGE STRIP WIDTH a3ftDEAD LOAD DR 3 psfCOMPONENTS AND CLADDING (Method 2)ROOF DEAD LOAD DP 3 psfENDWALL GIRT FEG 23 psfPARTITION DEAD LOAD DL 0 psfSIDEWALL GIRT FSG 22 psfADDITIONAL LONG. DEAD LOAD DT 0 psfPURLIN Fpurlin 21psfADDITIONAL TRANS, DEAD LOAD MAIN WIND FORCE (Method 2)BASE SHEAR LONGITUDINAL TRANSVERSE WALL SuctionandPressure()FW 16 psfSEISMIC V Ls 3336lbV Ts 145lb ROOF FR 8 psfWIND V Lw 1032lbV Tw 634lb ANCHOR INFORMATION EDGE DISTANCE EdgeDistance 3 P53988_#3.xmcd B1 3/25/2021 CONCRETE STRENGTH Concrete 2500 ϕN 0.65Table 3 - ESR-3889 ϕVs 0.60Table 4 - ESR-3889 ϕVc 0.70Table 4 - ESR-3889 do_.375 0.375indo_.5 0.5innominal anchor diameter (table 1 ESR 3889) hef_.375 1.33inhef_.375_3 1.75inhef_.5_2.5 1.75inhef_.5_3.5 2.17ineffective embedment (table 1 ESR 3889) cac_.375 5.0incac_.375_3 6.3incac_.5_2.5 3.3incac_.5_3.5 5.9incritical edge distance (table 1 ESR 3889) ψcn 1.0modification factor for cracked and uncraked concrete (tabel 4 ESR 3889 kc 17effectiveness factor for cracked concrete (table 4 ESR 3889) Np 0kipcharacteristic pulout strength, cracked concrete (table 4 ESR 3889) le_.375 1.33inle_.375_3 1.75inle_.5_2.5 1.75inle_.5_3.5 2.17inload bearing length of anchor (table 4 ESR 3889) Nsa_.375 8.730kipNsa_.5 20.475kipsteel strength in tension (table 3 ESR 3889) V sa_.375 3.465kipV sa_.5 8.860kipsteel strength in shear (table 4 ESR 3889) Corner Anchor nc 1number of bolts at column ca1_c 2.75indistance between bolts from edge 2 s1_c 0indistance between bolts along edge 1 ca2_c 2.75indistance of bolts from edge 1 s2_c 0indistance between bolts along edge 2 eN_c 0indistance from resultant tension load to centroid of anchors in tension ev_c 0indistance from sultant shear load to centroid of anchors in shear Exterior Anchor ne 2number of bolts at column ca1_e 2.75indistance between bolts from edge 2 s1_e 0indistance between bolts along edge 1 ca2_e 100indistance of bolts from edge 1 s2_e 5indistance between bolts along edge 2 eN_e 0indistance from resultant tension load to centroid of anchors in tension ev_e 0indistance from sultant shear load to centroid of anchors in shear Interior Anchor ni 1number of bolts at column ca1_i 100indistance between bolts from edge 2 s1_i 0indistance between bolts along edge 1 ca2_i 100indistance of bolts from edge 1 s2_i 0indistance between bolts along edge 2 eN_i 0indistance from resultant tension load to centroid of anchors in tension ev_i 0indistance from sultant shear load to centroid of anchors in shear P53988_#3.xmcd B2 3/25/2021 ANCHOR FORCE SUMMARY SHEAR UPLIFT WIND / LONGITUDINAL / INTERIOR V wil 0lbNwil 130lb WIND / LONGITUDINAL / EXTERIOR V wel 206lbNwel 198lb WIND / TRANSVERSE / INTERIOR V wit 70lbNwit 130lb WIND / TRANSVERSE / EXTERIOR V wet 211lbNwet 392lb SEISMIC / LONGITUDINAL / INTERIOR V sil 0lbNsil 280lb SEISMIC / LONGITUDINAL / EXTERIOR V sel 793lbNsel 679lb SEISMIC / TRANSVERSE / INTERIOR V sit 31lbNsit 280lb SEISMIC / TRANSVERSE / EXTERIOR V set 92lbNset 2lb ULTIMATE LOADS FOR ANCHORS Tension (Interior)Tension (Exterior)Shear (Interior)Shear (Exterior) TensionI 847.44lbTensionX 1316.03lbShearI 912.63lbShearX 1247.4lb Bolt Interatction Check Applied Uplift / Tension + Applied Shear / Shear < 1.2 Longitudinal Transverse Interior Anchors Wind Anchori_wl 0.15Wind Anchori_wt 0.23 Siesmic Anchori_sl 0Siesmic Anchori_st 0.03 Exterior Anchors Wind Anchore_wl 0.316Wind Anchore_wt 0.47 Siesmic Anchore_sl 1.15Siesmic Anchore_st 0.08 Cormer Anchors Wind Anchorc_wl 0.21Wind Anchorc_wt 0.21 Siesmic Anchorc_sl 0Siesmic Anchorc_st 0 ANCHOR Interior Anchori "3/8" x 2.5"" Exterior Anchore "3/8" x 2.5"" P53988_#3.xmcd B3 3/25/2021 PANEL CHECK PANEL CAPACITY V all 53 plf LONGITUDINAL SHEAR PANEL REQUIRED PanelLengthL 62.95ft LONGITUDINALSHEAR PANEL PanelL 0 TRANSVERSE SHEAR PANEL REQUIRED PanelLengthT 11.95ft TRANSVERSE SHEAR PANEL PanelT 20ft LONGITUDINAL SHEAR WALL PanelCheckL "not ok"(IF PANEL CHECK IS "OK" NO STRAP BRACES REQUIRED FOR LATERAL FORCE RESISTING SYSTEM BUT STRAPS MAY BE REQUIRED FOR ANCHORING)TRANSVERSE SHEAR WALL PanelCheckT "ok" STRAP BRACES (IF REQUIRED) LONGITUDINAL StrapsL 8 TRANSVERSE StrapsT 0 Allowable Tension in Strap Ta 2470.06lbGAUGE OF STRAP Gage 16STRAP WIDTH ws 2in Longitudinal Strap Angle BraceangleL 45.94 deg Transverse Strap Angle BraceangleT 45.94 deg Longitudinal Tension on Strap TL if PanelCheckL "ok"=0 max V Ls VLw cos BraceangleL TL 4797.41lb Transverse Tension on Strap TT if PanelCheckT "ok"=0 max V Ts VTw cos BraceangleT TT 0lb (Note: Compression member to be designed seperately, see additional calculations. Compression memeber needed only when StrapsT > 0) P53988_#3.xmcd B4 3/25/2021 INPUT VALUES PURLIN BRIDGING SPACING PurlinBridgeSpace 60 DEPTH OF PURLIN webP 77, 9, 11 or 12 JAMB SUPPORT StubPostJ "no"HEIGHT OF HORIZONTAL BRACING BridgeHeight 5.58ft Cbrace 2.79ftWIDTH OF INTERIOR COLUMN webI 3.5CORNER COLUMN UNBRACED LENGTH (y & t) SIDE WALL COLUMN webS 3.5ColumnNumberSW 2SIDEWALL GIRT webG webSGirtNumber 1 END WALL COLUMN webE 3.5ColumnNumberEW 2ENDWALL GIRT webGE webEEGirtNumber 1 END CLOSET COLUMN (JAMB)webEWC 3.5ColumnNumberEWC 1(Use either 3.5 or 5.5 for the width of Side Wall, End Wall or End Closet Columns)END CLOSET COLUMN (HDR)webEC 3.5ColumnNumberEC 1 STUB POST HEADER (L)webH 95.5", 9", 10" or 12"MembersHL 1 STUB POST HEADER (S)webHS 5.55.5", 9", 10" or 12"MembersHS 1 LOAD COMBINATIONS LC1 = D + MAX(S,Lr)EQUATION 16-10 LC2 = D + MAX(.75S,.75Lr)EQUATION 16-11 LC3 = D +MAX( .6W,.7E)EQUATION 16-12 LC4 = D + ..45W + MAX(.75S,.75Lr)EQUATION 16-13 LC5 = D + ..525E +.75S EQUATION 16-14 LC6 = .6D + MAX(.6W,.7E)EQUATION 16-15 EQUATION 16-16 PURLIN INFORMATION PURLIN LOADS UNIFORM LOAD END REACTION MOMENT LC1 wPurlin1 183 plfRPurlin1 915lbMPurlin1 2287lb ft LC4 wPurlin4 158 plfRPurlin4 789lbMPurlin4 1971lb ft LC6 wPurlin6 53plfRPurlin6 264lbMPurlin6 661lb ft LC6 wPurlin6e 74plfRPurlin6ea 317lbRPurlin6eb 274lbMPurlin6e 920lb ft PURLIN MemberPR "7 x 16ga, 50ksi Cee Purlin"IntPR 0.760 LxPR 118.5inLyPR 118.5inLtPR 118.5 inLyPR_neg 118.5 inLtPR_neg 118.5 in STUB POST HEADERS STUB POST HEADER LOADS REACTION MOMENT LC1 RH1 915lbMH1 4575lb ft LC4 RH4 789lbMH4 3943lb ft LC5 RH6 264lbMH6 1321lb ft MEMBER SIZES INTERACTION LENGTH STUB POST HEADERS MemberH "9 x 3.2 x 16ga 50 ksi Stub Header"IntH 0.992HeaderLength 10ft STUB POST HEADER BRACING LxH 120 inLyH 120 inLtH 120 in SMALL STUB POST HEADERS MemberHS "5.5 x 3.2 x 18ga 33 ksi Stub Header"IntHS 0.780SHLength 5ft SMALL STUB POST HEADER BRACING LxHS 60 inLyHS 60 inLtHS 60 in P53988_#3.xmcd B5 3/25/2021 INTERIOR COLUMNS INTERIOR COLUMN LOADS AXIAL LOAD MOMENT LC1 P I1 1830lbMI1 0 LC3 P I3 390lbMI3 0 LC4 P I4 1590lbMI4 292.25lb ft(Moment due to 5 psf horizontal load) LC5 P I5 1441lbMI5 292.25lb ft MEMBER SIZES INTERACTION INTERIOR COLUMN MemberI "3.63 x 2 x 14ga, 50 ksi Interior Column"IntI 0.815 INTERIOR COLUMN BRACING LxI 127 inLyI 12 inLtI 127 in JAMBS JAMB LOADS AXIAL LOAD MOMENT LC1 P Jamb1 915lbNA LC3 P Jamb3a 391lbMJamb3a 152lb ft LC3 P Jamb3b 527lbNA LC4 P Jamb4 942lbMJamb4 114lb ft LC5 P Jamb5 1044lbNA JAMB UNIFORM LOAD swjamb 122 plfwEWJamb 69 plf JAMB APPLIED MOMENT JambMoment 152lb ftEWJambMoment 86lb ft JAMB AXIAL LOAD P Jamb1 915lb JAMB MOMENT CAPACITY Mjambcap 971lb ft JAMB AXIAL CAPACITY P jambcap 5691lb JAMB CHECK JambCheck "ok"EWJambCheck "ok" MEMBER SIZES END WALL HEADER MOMENT CAPACTIY EWheadermomenallt 2922lb ft END WALL HEADER APPLIED MOMENT EWhedermomentapp 2287.5lb ft LARGE END WALL HEADER CHECK EWheader_check16 "16in_EW Header O.K." EWheader_check22 "22in_EW Header O.K." SIDE WALL COLUMNS SIDE WALL LOADS AXIAL SIDE WALL MOMENT LC1 P SW1 915lbMSW 0lbft LC3 P SW3 391lb LC4 P SW4 942lb MEMBER SIZES INTERACTION SIDE WALL COLUMN MemberSW "3.63 x 1.5 x 18ga 33 ksi Column"IntSW 0.345 SIDE WALL COLUMN BRACING LxS 134 inLyS 34 inLtS 34 in P53988_#3.xmcd B6 3/25/2021 END WALL COLUMNS END WALL LOADS AXIAL LOAD UNIFORM LOAD MOMENT LC1 P EW1 915lbNA NA LC3 P EW3 391lbwEW3 48 plfMEW3 748lb ft LC4 P EW4 942lbwEW4 36 plfMEW4 561lb ft MEMBER SIZES INTERACTION END WALL COLUMN MemberEW "3.63 x 1.5 x 16ga 50 ksi Column"IntEW 0.594 END WALL COLUMN BRACING LxE 127 inLyE 41 inLtE 41 in GIRTS GIRT LOADS UNIFORM LOAD END REACTION MOMENT wGS 37 plfRGS 186lbMGS 465lb ftSIDE WALL GIRT IN MID ZONE wGSe 44 plfRGSe 222lbMGSe 555lb ftSIDE WALL GIRT IN END ZONE wGE 47 plfRGE 235lbMGE 147lb ftGIRT IN MID ZONE wGEe 57 plfRGEe 286lbMGEe 179lb ftGIRT IN END ZONE MEMBER SIZES INTERACTION SIDE WALL GIRT (MID)MemberGS "3.5 x 1.75 x 18ga 33 ksi Girt"IntGS 0.821 END WALL GIRT (END)MemberGE "3.5 x 1.75 x 18ga 33 ksi Girt"IntGE 0.264 SIDE WALL GIRT BRACING LtG 119 in END WALL GIRT BRACING LtGE 59 in STUDS STUD SPACING StudSpacing 16 in STUD LOADS UNIFORM LOAD MOMENT wStud 19 plfMStud 289lb ftSIDE WALL STUD IN MID ZONE wStude 23 plfMStude 353lb ftSIDE WALL STUD IN END ZONE MEMBER SIZES INTERACTION SIDE WALL STUD MemberStud "3.625 x 2 x 20ga 33 ksi Stud"IntStud 0.612 SIDE WALL STUB BRACING LxStud 134 inLyStud 34 inLtStud 34 in FOUNDATION INFORMATION INTERIOR COLUMN REACTIONS GRAVITY P down_interior 1830lbUPLIFT P up_int 100lb EXTERIOR COLUMN REACTIONS GRAVITY P down_exterior 942lbUPLIFT P up_ext 362lb ALLOWABLE BEARING PRESSURE BearingPressure 1500 psf SLAB THICKNESS Slab 5 in PAD WIDTH PadW "na" in PAD DEPTH PadD "na" in LxG 119 in LxGE 59 inLyGE 12 in LyG 12 in P53988_#3.xmcd B7 3/25/2021 TRACHTE BUILDING SYSTEMS, INC. PROJECT CALCULATIONS CUSTOMER "Brandon Roberts"PREPARED_BY "Claire Z. Robinson" LOCATION "Thorton, ID"REVIEWED_BY PLAN_NUMBER "P53988" BUILDING "#4 and #5_10ft Bay" CODEBODY "IBC 2018" BUILDING DESCRIPTION BAY WIDTH bay 10ftPURLIN BRIDGING PBridging "no" ROOF PITCH Rpitch 0.5 in ftBUILDING HEIGHT height 9ft 4inROOF MATERIAL Roof "SSR" BUILDING WIDTH width 20ftPURLIN SPACING P space 5ft ROOF ANGLE θ 2.39degBUILDING LENGTH length 140ftINT. PARTITION PANEL Ptpanel "yes" ROOF TYPE Type "Lean-to"FLOOR TO FLOOR lower 0ftINT. LATERAL BRIDGING Bridge "no" RISK CATEGORY UseGroup "I"Use "I" or "II"FOUNDATION SLOPE Fndslope 0% SNOW LOAD SEISMIC LOAD P g 50psfGROUND SNOW LOAD ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE E snow "C"SNOW EXPOSURE CATEGORY BUILDING FRAME SYSTEM BFS "Light Frame Wall w/ Flat Strap Bracing" IS 0.8SNOW IMPORTANCE FACTOR SEISMIC SITE CLASS Siteclass "D" Ct 1.2THERMAL FACTOR SHORT PERIOD SPECTIAL ACC.S S 0.368 Exp "Partial"SNOW EXPOSURE 1 SECOND PERIOD SPECTRAL ACC.S 1 0.141 Lr 20psfROOF LIVE LOAD FLAT ROOF SNOW LOAD P f 34psfSPECTRAL RESPONSE ACC.S DS 0.37 UNBALANCE SNOW LOAD P unbalanced 34psfSPECTRAL RESPONCE ACC.S D1 0.21 SNOW LOAD USED IN DESIGN P S 34psfRESPONSE FACTOR Response 4 RAIN SURCHARGE RainSurcharge 0 psfSEISMIC DESIGN CATEGORY SeismicDC "D" WIND LOAD SEISMIC RESPONSE COFFICIENT Cs 0.09WIND VELOCITY V ult 100mph V asd 77mph WIND EXPOSURE CATEGORY E wind "C" EDGE STRIP WIDTH a3ftDEAD LOAD DR 3 psfCOMPONENTS AND CLADDING (Method 2)ROOF DEAD LOAD DP 3 psfENDWALL GIRT FEG 23psfPARTITION DEAD LOAD DL 0 psfSIDEWALL GIRT FSG 22psfADDITIONAL LONG. DEAD LOAD DT 0 psfPURLIN Fpurlin 21psfADDITIONAL TRANS, DEAD LOAD MAIN WIND FORCE (Method 2)BASE SHEAR LONGITUDINAL TRANSVERSE WALL SuctionandPressure()FW 16psfSEISMIC V Ls 2031lbV Ts 145lb ROOF FR 8 psfWIND V Lw 936lbV Tw 572lb ANCHOR INFORMATION EDGE DISTANCE EdgeDistance 3 P53988_#4,#5_10ft Bay.xmcd C1 3/25/2021 CONCRETE STRENGTH Concrete 2500 ϕN 0.65Table 3 - ESR-3889 ϕVs 0.60Table 4 - ESR-3889 ϕVc 0.70Table 4 - ESR-3889 do_.375 0.375indo_.5 0.5innominal anchor diameter (table 1 ESR 3889) hef_.375 1.33inhef_.375_3 1.75inhef_.5_2.5 1.75inhef_.5_3.5 2.17ineffective embedment (table 1 ESR 3889) cac_.375 5.0incac_.375_3 6.3incac_.5_2.5 3.3incac_.5_3.5 5.9incritical edge distance (table 1 ESR 3889) ψcn 1.0modification factor for cracked and uncraked concrete (tabel 4 ESR 3889 kc 17effectiveness factor for cracked concrete (table 4 ESR 3889) Np 0kipcharacteristic pulout strength, cracked concrete (table 4 ESR 3889) le_.375 1.33inle_.375_3 1.75inle_.5_2.5 1.75inle_.5_3.5 2.17inload bearing length of anchor (table 4 ESR 3889) Nsa_.375 8.730kipNsa_.5 20.475kipsteel strength in tension (table 3 ESR 3889) V sa_.375 3.465kipV sa_.5 8.860kipsteel strength in shear (table 4 ESR 3889) Corner Anchor nc 1number of bolts at column ca1_c 2.75indistance between bolts from edge 2 s1_c 0indistance between bolts along edge 1 ca2_c 2.75indistance of bolts from edge 1 s2_c 0indistance between bolts along edge 2 eN_c 0indistance from resultant tension load to centroid of anchors in tension ev_c 0indistance from sultant shear load to centroid of anchors in shear Exterior Anchor ne 2number of bolts at column ca1_e 2.75indistance between bolts from edge 2 s1_e 0indistance between bolts along edge 1 ca2_e 100indistance of bolts from edge 1 s2_e 5indistance between bolts along edge 2 eN_e 0indistance from resultant tension load to centroid of anchors in tension ev_e 0indistance from sultant shear load to centroid of anchors in shear Interior Anchor ni 1number of bolts at column ca1_i 100indistance between bolts from edge 2 s1_i 0indistance between bolts along edge 1 ca2_i 100indistance of bolts from edge 1 s2_i 0indistance between bolts along edge 2 eN_i 0indistance from resultant tension load to centroid of anchors in tension ev_i 0indistance from sultant shear load to centroid of anchors in shear P53988_#4,#5_10ft Bay.xmcd C2 3/25/2021 ANCHOR FORCE SUMMARY SHEAR UPLIFT WIND / LONGITUDINAL / INTERIOR V wil 0lbNwil 130lb WIND / LONGITUDINAL / EXTERIOR V wel 187lbNwel 240lb WIND / TRANSVERSE / INTERIOR V wit 64lbNwit 130lb WIND / TRANSVERSE / EXTERIOR V wet 191lbNwet 332lb SEISMIC / LONGITUDINAL / INTERIOR V sil 0lbNsil 280lb SEISMIC / LONGITUDINAL / EXTERIOR V sel 772lbNsel 581lb SEISMIC / TRANSVERSE / INTERIOR V sit 31lbNsit 280lb SEISMIC / TRANSVERSE / EXTERIOR V set 92lbNset 11lb ULTIMATE LOADS FOR ANCHORS Tension (Interior)Tension (Exterior)Shear (Interior)Shear (Exterior) TensionI 847.44lbTensionX 1316.03lbShearI 912.63lbShearX 1247.4lb Bolt Interatction Check Applied Uplift / Tension + Applied Shear / Shear < 1.2 Longitudinal Transverse Interior Anchors Wind Anchori_wl 0.15Wind Anchori_wt 0.22 Siesmic Anchori_sl 0Siesmic Anchori_st 0.03 Exterior Anchors Wind Anchore_wl 0.332Wind Anchore_wt 0.41 Siesmic Anchore_sl 1.06Siesmic Anchore_st 0.07 Cormer Anchors Wind Anchorc_wl 0.21Wind Anchorc_wt 0.21 Siesmic Anchorc_sl 0Siesmic Anchorc_st 0 ANCHOR Interior Anchori "3/8" x 2.5"" Exterior Anchore "3/8" x 2.5"" P53988_#4,#5_10ft Bay.xmcd C3 3/25/2021 PANEL CHECK PANEL CAPACITY V all 53 plf LONGITUDINAL SHEAR PANEL REQUIRED PanelLengthL 38.32ft LONGITUDINALSHEAR PANEL PanelL 0 TRANSVERSE SHEAR PANEL REQUIRED PanelLengthT 10.8ft TRANSVERSE SHEAR PANEL PanelT 20ft LONGITUDINAL SHEAR WALL PanelCheckL "not ok"(IF PANEL CHECK IS "OK" NO STRAP BRACES REQUIRED FOR LATERAL FORCE RESISTING SYSTEM BUT STRAPS MAY BE REQUIRED FOR ANCHORING)TRANSVERSE SHEAR WALL PanelCheckT "ok" STRAP BRACES (IF REQUIRED) LONGITUDINAL StrapsL 5 TRANSVERSE StrapsT 0 Allowable Tension in Strap Ta 2470.06lbGAUGE OF STRAP Gage 16STRAP WIDTH ws 2in Longitudinal Strap Angle BraceangleL 43.03 deg Transverse Strap Angle BraceangleT 43.03 deg Longitudinal Tension on Strap TL if PanelCheckL "ok"=0 max V Ls VLw cos BraceangleL TL 2777.83lb Transverse Tension on Strap TT if PanelCheckT "ok"=0 max V Ts VTw cos BraceangleT TT 0lb (Note: Compression member to be designed seperately, see additional calculations. Compression memeber needed only when StrapsT > 0) P53988_#4,#5_10ft Bay.xmcd C4 3/25/2021 INPUT VALUES PURLIN BRIDGING SPACING PurlinBridgeSpace 60 DEPTH OF PURLIN webP 77, 9, 11 or 12 JAMB SUPPORT StubPostJ "no"HEIGHT OF HORIZONTAL BRACING BridgeHeight 5.08ft Cbrace 3.39ftWIDTH OF INTERIOR COLUMN webI 3.5CORNER COLUMN UNBRACED LENGTH (y & t) SIDE WALL COLUMN webS 3.5ColumnNumberSW 2SIDEWALL GIRT webG webSGirtNumber 1 END WALL COLUMN webE 3.5ColumnNumberEW 2ENDWALL GIRT webGE webEEGirtNumber 1 END CLOSET COLUMN (JAMB)webEWC 3.5ColumnNumberEWC 1(Use either 3.5 or 5.5 for the width of Side Wall, End Wall or End Closet Columns)END CLOSET COLUMN (HDR)webEC 3.5ColumnNumberEC 1 STUB POST HEADER (L)webH 95.5", 9", 10" or 12"MembersHL 1 STUB POST HEADER (S)webHS 5.55.5", 9", 10" or 12"MembersHS 1 LOAD COMBINATIONS LC1 = D + MAX(S,Lr)EQUATION 16-10 LC2 = D + MAX(.75S,.75Lr)EQUATION 16-11 LC3 = D +MAX( .6W,.7E)EQUATION 16-12 LC4 = D + ..45W + MAX(.75S,.75Lr)EQUATION 16-13 LC5 = D + ..525E +.75S EQUATION 16-14 LC6 = .6D + MAX(.6W,.7E)EQUATION 16-15 EQUATION 16-16 PURLIN INFORMATION PURLIN LOADS UNIFORM LOAD END REACTION MOMENT LC1 wPurlin1 183 plfRPurlin1 915lbMPurlin1 2287lb ft LC4 wPurlin4 158 plfRPurlin4 789lbMPurlin4 1971lb ft LC6 wPurlin6 53plfRPurlin6 264lbMPurlin6 661lb ft LC6 wPurlin6e 74plfRPurlin6ea 317lbRPurlin6eb 274lbMPurlin6e 920lb ft PURLIN MemberPR "7 x 16ga, 50ksi Cee Purlin"IntPR 0.760 LxPR 118.5inLyPR 118.5inLtPR 118.5 inLyPR_neg 118.5 inLtPR_neg 118.5 in STUB POST HEADERS STUB POST HEADER LOADS REACTION MOMENT LC1 RH1 915lbMH1 4575lb ft LC4 RH4 789lbMH4 3943lb ft LC5 RH6 264lbMH6 1321lb ft MEMBER SIZES INTERACTION LENGTH STUB POST HEADERS MemberH "9 x 3.2 x 16ga 50 ksi Stub Header"IntH 0.992HeaderLength 10ft STUB POST HEADER BRACING LxH 120 inLyH 120 inLtH 120 in SMALL STUB POST HEADERS MemberHS "5.5 x 3.2 x 18ga 33 ksi Stub Header"IntHS 0.780SHLength 5ft SMALL STUB POST HEADER BRACING LxHS 60 inLyHS 60 inLtHS 60 in P53988_#4,#5_10ft Bay.xmcd C5 3/25/2021 INTERIOR COLUMNS INTERIOR COLUMN LOADS AXIAL LOAD MOMENT LC1 P I1 1830lbMI1 0 LC3 P I3 390lbMI3 0 LC4 P I4 1590lbMI4 242.25lb ft(Moment due to 5 psf horizontal load) LC5 P I5 1441lbMI5 242.25lb ft MEMBER SIZES INTERACTION INTERIOR COLUMN MemberI "3.63 x 2 x 16ga, 50 ksi Interior Column"IntI 0.875 INTERIOR COLUMN BRACING LxI 115 inLyI 12 inLtI 115 in JAMBS JAMB LOADS AXIAL LOAD MOMENT LC1 P Jamb1 915lbNA LC3 P Jamb3a 355lbMJamb3a 187lb ft LC3 P Jamb3b 475lbNA LC4 P Jamb4 915lbMJamb4 140lb ft LC5 P Jamb5 1005lbNA JAMB UNIFORM LOAD swjamb 120 plfwEWJamb 69 plf JAMB APPLIED MOMENT JambMoment 187lb ftEWJambMoment 108lb ft JAMB AXIAL LOAD P Jamb1 915lb JAMB MOMENT CAPACITY Mjambcap 971lb ft JAMB AXIAL CAPACITY P jambcap 5691lb JAMB CHECK JambCheck "ok"EWJambCheck "ok" MEMBER SIZES END WALL HEADER MOMENT CAPACTIY EWheadermomenallt 2922lb ft END WALL HEADER APPLIED MOMENT EWhedermomentapp 2287.5lb ft LARGE END WALL HEADER CHECK EWheader_check16 "16in_EW Header O.K." EWheader_check22 "22in_EW Header O.K." SIDE WALL COLUMNS SIDE WALL LOADS AXIAL SIDE WALL MOMENT LC1 P SW1 915lbMSW 0lbft LC3 P SW3 355lb LC4 P SW4 915lb MEMBER SIZES INTERACTION SIDE WALL COLUMN MemberSW "3.63 x 1.5 x 18ga 33 ksi Column"IntSW 0.346 SIDE WALL COLUMN BRACING LxS 122 inLyS 41 inLtS 41 in P53988_#4,#5_10ft Bay.xmcd C6 3/25/2021 END WALL COLUMNS END WALL LOADS AXIAL LOAD UNIFORM LOAD MOMENT LC1 P EW1 915lbNA NA LC3 P EW3 355lbwEW3 48 plfMEW3 620lb ft LC4 P EW4 915lbwEW4 36 plfMEW4 465lb ft MEMBER SIZES INTERACTION END WALL COLUMN MemberEW "3.63 x 1.5 x 18ga 33 ksi Column"IntEW 0.900 END WALL COLUMN BRACING LxE 115 inLyE 38 inLtE 38 in GIRTS GIRT LOADS UNIFORM LOAD END REACTION MOMENT wGS 45 plfRGS 223lbMGS 557lb ftSIDE WALL GIRT IN MID ZONE wGSe 53 plfRGSe 264lbMGSe 659lb ftSIDE WALL GIRT IN END ZONE wGE 44 plfRGE 219lbMGE 137lb ftGIRT IN MID ZONE wGEe 53 plfRGEe 267lbMGEe 167lb ftGIRT IN END ZONE MEMBER SIZES INTERACTION SIDE WALL GIRT (MID)MemberGS "3.5 x 1.75 x 18ga 33 ksi Girt"IntGS 0.976 END WALL GIRT (END)MemberGE "3.5 x 1.75 x 18ga 33 ksi Girt"IntGE 0.247 SIDE WALL GIRT BRACING LtG 119 in END WALL GIRT BRACING LtGE 59 in STUDS STUD SPACING StudSpacing 16 in STUD LOADS UNIFORM LOAD MOMENT wStud 19 plfMStud 241lb ftSIDE WALL STUD IN MID ZONE wStude 23 plfMStude 295lb ftSIDE WALL STUD IN END ZONE MEMBER SIZES INTERACTION SIDE WALL STUD MemberStud "3.625 x 2 x 20ga 33 ksi Stud"IntStud 0.512 SIDE WALL STUB BRACING LxStud 122 inLyStud 41 inLtStud 41 in FOUNDATION INFORMATION INTERIOR COLUMN REACTIONS GRAVITY P down_interior 1830lbUPLIFT P up_int 100lb EXTERIOR COLUMN REACTIONS GRAVITY P down_exterior 915lbUPLIFT P up_ext 310lb ALLOWABLE BEARING PRESSURE BearingPressure 1500 psf SLAB THICKNESS Slab 5 in PAD WIDTH PadW "na" in PAD DEPTH PadD "na" in LxG 119 in LxGE 59 inLyGE 12 in LyG 12 in P53988_#4,#5_10ft Bay.xmcd C7 3/25/2021 TRACHTE BUILDING SYSTEMS, INC. PROJECT CALCULATIONS CUSTOMER "Brandon Roberts"PREPARED_BY "Claire Z. Robinson" LOCATION "Thorton, ID"REVIEWED_BY PLAN_NUMBER "P53988" BUILDING "#4_20ft Bay" CODEBODY "IBC 2018" BUILDING DESCRIPTION BAY WIDTH bay 20ftPURLIN BRIDGING PBridging "yes" ROOF PITCH Rpitch 0.5 in ftBUILDING HEIGHT height 9ft 4inROOF MATERIAL Roof "SSR" BUILDING WIDTH width 20ftPURLIN SPACING P space 5ft ROOF ANGLE θ 2.39 degBUILDING LENGTH length 110ftINT. PARTITION PANEL Ptpanel "yes" ROOF TYPE Type "Lean-to"FLOOR TO FLOOR lower 0ftINT. LATERAL BRIDGING Bridge "yes" RISK CATEGORY UseGroup "I"Use "I" or "II"FOUNDATION SLOPE Fndslope 0% SNOW LOAD SEISMIC LOAD P g 50psfGROUND SNOW LOAD ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE E snow "C"SNOW EXPOSURE CATEGORY BUILDING FRAME SYSTEM BFS "Light Frame Wall w/ Flat Strap Bracing" IS 0.8SNOW IMPORTANCE FACTOR SEISMIC SITE CLASS Siteclass "D" Ct 1.2THERMAL FACTOR SHORT PERIOD SPECTIAL ACC.S S 0.368 Exp "Partial"SNOW EXPOSURE 1 SECOND PERIOD SPECTRAL ACC.S 1 0.141 Lr 20psfROOF LIVE LOAD FLAT ROOF SNOW LOAD P f 34 psfSPECTRAL RESPONSE ACC.S DS 0.37 UNBALANCE SNOW LOAD P unbalanced 34 psfSPECTRAL RESPONCE ACC.S D1 0.21 SNOW LOAD USED IN DESIGN P S 34 psfRESPONSE FACTOR Response 4 RAIN SURCHARGE RainSurcharge 0 psfSEISMIC DESIGN CATEGORY SeismicDC "D" WIND LOAD SEISMIC RESPONSE COFFICIENT Cs 0.09WIND VELOCITY V ult 100mph V asd 77 mph WIND EXPOSURE CATEGORY E wind "C" EDGE STRIP WIDTH a3ftDEAD LOAD DR 3 psfCOMPONENTS AND CLADDING (Method 2)ROOF DEAD LOAD DP 3 psfENDWALL GIRT FEG 23 psfPARTITION DEAD LOAD DL 0 psfSIDEWALL GIRT FSG 21 psfADDITIONAL LONG. DEAD LOAD DT 0 psfPURLIN Fpurlin 20psfADDITIONAL TRANS, DEAD LOAD MAIN WIND FORCE (Method 2)BASE SHEAR LONGITUDINAL TRANSVERSE WALL SuctionandPressure()FW 16 psfSEISMIC V Ls 1596lbV Ts 290lb ROOF FR 8 psfWIND V Lw 936lbV Tw 1145lb ANCHOR INFORMATION EDGE DISTANCE EdgeDistance 3 P53988_#4_20ft Bay.xmcd D1 3/25/2021 CONCRETE STRENGTH Concrete 2500 ϕN 0.65Table 3 - ESR-3889 ϕVs 0.60Table 4 - ESR-3889 ϕVc 0.70Table 4 - ESR-3889 do_.375 0.375indo_.5 0.5innominal anchor diameter (table 1 ESR 3889) hef_.375 1.33inhef_.375_3 1.75inhef_.5_2.5 1.75inhef_.5_3.5 2.17ineffective embedment (table 1 ESR 3889) cac_.375 5.0incac_.375_3 6.3incac_.5_2.5 3.3incac_.5_3.5 5.9incritical edge distance (table 1 ESR 3889) ψcn 1.0modification factor for cracked and uncraked concrete (tabel 4 ESR 3889 kc 17effectiveness factor for cracked concrete (table 4 ESR 3889) Np 0kipcharacteristic pulout strength, cracked concrete (table 4 ESR 3889) le_.375 1.33inle_.375_3 1.75inle_.5_2.5 1.75inle_.5_3.5 2.17inload bearing length of anchor (table 4 ESR 3889) Nsa_.375 8.730kipNsa_.5 20.475kipsteel strength in tension (table 3 ESR 3889) V sa_.375 3.465kipV sa_.5 8.860kipsteel strength in shear (table 4 ESR 3889) Corner Anchor nc 1number of bolts at column ca1_c 2.75indistance between bolts from edge 2 s1_c 0indistance between bolts along edge 1 ca2_c 2.75indistance of bolts from edge 1 s2_c 0indistance between bolts along edge 2 eN_c 0indistance from resultant tension load to centroid of anchors in tension ev_c 0indistance from sultant shear load to centroid of anchors in shear Exterior Anchor ne 2number of bolts at column ca1_e 2.75indistance between bolts from edge 2 s1_e 0indistance between bolts along edge 1 ca2_e 100indistance of bolts from edge 1 s2_e 5indistance between bolts along edge 2 eN_e 0indistance from resultant tension load to centroid of anchors in tension ev_e 0indistance from sultant shear load to centroid of anchors in shear Interior Anchor ni 1number of bolts at column ca1_i 100indistance between bolts from edge 2 s1_i 0indistance between bolts along edge 1 ca2_i 100indistance of bolts from edge 1 s2_i 0indistance between bolts along edge 2 eN_i 0indistance from resultant tension load to centroid of anchors in tension ev_i 0indistance from sultant shear load to centroid of anchors in shear P53988_#4_20ft Bay.xmcd D2 3/25/2021 ANCHOR FORCE SUMMARY SHEAR UPLIFT WIND / LONGITUDINAL / INTERIOR V wil 0lbNwil 260lb WIND / LONGITUDINAL / EXTERIOR V wel 187lbNwel 217lb WIND / TRANSVERSE / INTERIOR V wit 0lbNwit 260lb WIND / TRANSVERSE / EXTERIOR V wet 1717lbNwet 1198lb SEISMIC / LONGITUDINAL / INTERIOR V sil 0lbNsil 561lb SEISMIC / LONGITUDINAL / EXTERIOR V sel 607lbNsel 3lb SEISMIC / TRANSVERSE / INTERIOR V sit 0lbNsit 561lb SEISMIC / TRANSVERSE / EXTERIOR V set 552lbNset 235lb ULTIMATE LOADS FOR ANCHORS Tension (Interior)Tension (Exterior)Shear (Interior)Shear (Exterior) TensionI 847.44lbTensionX 3007.84lbShearI 912.63lbShearX 3189.6lb Bolt Interatction Check Applied Uplift / Tension + Applied Shear / Shear < 1.2 Longitudinal Transverse Interior Anchors Wind Anchori_wl 0.31Wind Anchori_wt 0.31 Siesmic Anchori_sl 0Siesmic Anchori_st 0 Exterior Anchors Wind Anchore_wl 0.131Wind Anchore_wt 0.94 Siesmic Anchore_sl 0.19Siesmic Anchore_st 0.25 Cormer Anchors Wind Anchorc_wl 0.43Wind Anchorc_wt 0.43 Siesmic Anchorc_sl 0Siesmic Anchorc_st 0 ANCHOR Interior Anchori "3/8" x 2.5"" Exterior Anchore "1/2" x 3"" P53988_#4_20ft Bay.xmcd D3 3/25/2021 PANEL CHECK PANEL CAPACITY V all 53 plf LONGITUDINAL SHEAR PANEL REQUIRED PanelLengthL 30.11ft LONGITUDINALSHEAR PANEL PanelL 0 TRANSVERSE SHEAR PANEL REQUIRED PanelLengthT 21.59ft TRANSVERSE SHEAR PANEL PanelT 20ft LONGITUDINAL SHEAR WALL PanelCheckL "not ok"(IF PANEL CHECK IS "OK" NO STRAP BRACES REQUIRED FOR LATERAL FORCE RESISTING SYSTEM BUT STRAPS MAY BE REQUIRED FOR ANCHORING)TRANSVERSE SHEAR WALL PanelCheckT "not ok" STRAP BRACES (IF REQUIRED) LONGITUDINAL StrapsL 5 TRANSVERSE StrapsT 1 Allowable Tension in Strap Ta 2470.06lbGAUGE OF STRAP Gage 16STRAP WIDTH ws 2in Longitudinal Strap Angle BraceangleL 25.02 deg Transverse Strap Angle BraceangleT 43.03 deg Longitudinal Tension on Strap TL if PanelCheckL "ok"=0 max V Ls VLw cos BraceangleL TL 1760.77lb Transverse Tension on Strap TT if PanelCheckT "ok"=0 max V Ts VTw cos BraceangleT TT 1565.59lb (Note: Compression member to be designed seperately, see additional calculations. Compression memeber needed only when StrapsT > 0) P53988_#4_20ft Bay.xmcd D4 3/25/2021 INPUT VALUES PURLIN BRIDGING SPACING PurlinBridgeSpace 60 DEPTH OF PURLIN webP 97, 9, 11 or 12 JAMB SUPPORT StubPostJ "no"HEIGHT OF HORIZONTAL BRACING BridgeHeight 5.08ft Cbrace 3.39ftWIDTH OF INTERIOR COLUMN webI 3.5CORNER COLUMN UNBRACED LENGTH (y & t) SIDE WALL COLUMN webS 3.5ColumnNumberSW 2SIDEWALL GIRT webG webSGirtNumber 1 END WALL COLUMN webE 3.5ColumnNumberEW 2ENDWALL GIRT webGE webEEGirtNumber 1 END CLOSET COLUMN (JAMB)webEWC 3.5ColumnNumberEWC 1(Use either 3.5 or 5.5 for the width of Side Wall, End Wall or End Closet Columns)END CLOSET COLUMN (HDR)webEC 3.5ColumnNumberEC 1 STUB POST HEADER (L)webH 95.5", 9", 10" or 12"MembersHL 1 STUB POST HEADER (S)webHS 5.55.5", 9", 10" or 12"MembersHS 1 LOAD COMBINATIONS LC1 = D + MAX(S,Lr)EQUATION 16-10 LC2 = D + MAX(.75S,.75Lr)EQUATION 16-11 LC3 = D +MAX( .6W,.7E)EQUATION 16-12 LC4 = D + ..45W + MAX(.75S,.75Lr)EQUATION 16-13 LC5 = D + ..525E +.75S EQUATION 16-14 LC6 = .6D + MAX(.6W,.7E)EQUATION 16-15 EQUATION 16-16 PURLIN INFORMATION PURLIN LOADS UNIFORM LOAD END REACTION MOMENT LC1 wPurlin1 183 plfRPurlin1 1830lbMPurlin1 9150ft lb LC4 wPurlin4 157 plfRPurlin4 1568lbMPurlin4 7841ft lb LC6 wPurlin6 51plfRPurlin6 509lbMPurlin6 2546ft lb LC6 wPurlin6e 62plfRPurlin6ea 540lbRPurlin6eb 512lbMPurlin6e 3101ft lb PURLIN MemberPR "9 x 12ga, 50ksi Cee Purlin"IntPR 0.929 LxPR 238.5inLyPR 60 inLtPR 60 inLyPR_neg 60 inLtPR_neg 60 in STUB POST HEADERS STUB POST HEADER LOADS REACTION MOMENT LC1 RH1 1830lbMH1 9150ft lb LC4 RH4 1568lbMH4 7841ft lb LC5 RH6 509lbMH6 2546ft lb MEMBER SIZES INTERACTION LENGTH STUB POST HEADERS MemberH 999IntH 999.000HeaderLength 10ft STUB POST HEADER BRACING LxH 120 inLyH 120 inLtH 120 in SMALL STUB POST HEADERS MemberHS "5.5 x 3.2 x 16ga 50 ksi Stub Header"IntHS 0.867SHLength 5ft SMALL STUB POST HEADER BRACING LxHS 60 inLyHS 60 inLtHS 60 in P53988_#4_20ft Bay.xmcd D5 3/25/2021 INTERIOR COLUMNS INTERIOR COLUMN LOADS AXIAL LOAD MOMENT LC1 P I1 3660lbMI1 0 LC3 P I3 780lbMI3 0 LC4 P I4 3180lbMI4 242.25ft lb(Moment due to 5 psf horizontal load) LC5 P I5 2882lbMI5 242.25ft lb MEMBER SIZES INTERACTION INTERIOR COLUMN MemberI "3.63 x 2 x 16ga, 50 ksi Interior Column"IntI 0.784 INTERIOR COLUMN BRACING LxI 113 inLyI 12 inLtI 61 in JAMBS JAMB LOADS AXIAL LOAD MOMENT LC1 P Jamb1 1830lbNA LC3 P Jamb3a 1031lbMJamb3a 355ft lb LC3 P Jamb3b 462lbNA LC4 P Jamb4 2071lbMJamb4 266ft lb LC5 P Jamb5 1644lbNA JAMB UNIFORM LOAD swjamb 228 plfwEWJamb 69 plf JAMB APPLIED MOMENT JambMoment 355ft lbEWJambMoment 108ft lb JAMB AXIAL LOAD P Jamb1 1830lb JAMB MOMENT CAPACITY Mjambcap 971ft lb JAMB AXIAL CAPACITY P jambcap 5691lb JAMB CHECK JambCheck "ok"EWJambCheck "ok" MEMBER SIZES END WALL HEADER MOMENT CAPACTIY EWheadermomenallt 5845ft lb END WALL HEADER APPLIED MOMENT EWhedermomentapp 9150ft lb LARGE END WALL HEADER CHECK EWheader_check16 "Split End Closet into (2) Bays" EWheader_check22 "Split End Closet into (2) Bays" SIDE WALL COLUMNS SIDE WALL LOADS AXIAL SIDE WALL MOMENT LC1 P SW1 1830lbMSW 0ftlb LC3 P SW3 1031lb LC4 P SW4 2071lb MEMBER SIZES INTERACTION SIDE WALL COLUMN MemberSW "3.63 x 1.5 x 18ga 33 ksi Column"IntSW 0.782 SIDE WALL COLUMN BRACING LxS 122 inLyS 41 inLtS 41 in P53988_#4_20ft Bay.xmcd D6 3/25/2021 END WALL COLUMNS END WALL LOADS AXIAL LOAD UNIFORM LOAD MOMENT LC1 P EW1 1830lbNA NA LC3 P EW3 1031lbwEW3 48 plfMEW3 620ft lb LC4 P EW4 2071lbwEW4 36 plfMEW4 465ft lb MEMBER SIZES INTERACTION END WALL COLUMN MemberEW "3.63 x 1.5 x 16ga 50 ksi Column"IntEW 0.752 END WALL COLUMN BRACING LxE 113 inLyE 38 inLtE 38 in GIRTS GIRT LOADS UNIFORM LOAD END REACTION MOMENT wGS 42 plfRGS 425lbMGS 2123ft lbSIDE WALL GIRT IN MID ZONE wGSe 49 plfRGSe 487lbMGSe 2437ft lbSIDE WALL GIRT IN END ZONE wGE 44 plfRGE 438lbMGE 137ft lbGIRT IN MID ZONE wGEe 53 plfRGEe 534lbMGEe 167ft lbGIRT IN END ZONE MEMBER SIZES INTERACTION SIDE WALL GIRT (MID)MemberGS 999IntGS 999.000 END WALL GIRT (END)MemberGE "3.5 x 1.75 x 18ga 33 ksi Girt"IntGE 0.247 SIDE WALL GIRT BRACING LtG 239 in END WALL GIRT BRACING LtGE 59 in STUDS STUD SPACING StudSpacing 16 in STUD LOADS UNIFORM LOAD MOMENT wStud 19 plfMStud 241ft lbSIDE WALL STUD IN MID ZONE wStude 23 plfMStude 295ft lbSIDE WALL STUD IN END ZONE MEMBER SIZES INTERACTION SIDE WALL STUD MemberStud "3.625 x 2 x 20ga 33 ksi Stud"IntStud 0.512 SIDE WALL STUB BRACING LxStud 122 inLyStud 41 inLtStud 41 in FOUNDATION INFORMATION INTERIOR COLUMN REACTIONS GRAVITY P down_interior 3660lbUPLIFT P up_int 200lb EXTERIOR COLUMN REACTIONS GRAVITY P down_exterior 2071lbUPLIFT P up_ext 701lb ALLOWABLE BEARING PRESSURE BearingPressure 1500 psf SLAB THICKNESS Slab 4 in PAD WIDTH PadW 20 in PAD DEPTH PadD 8in LxG 239 in LxGE 59 inLyGE 12 in LyG 12 in P53988_#4_20ft Bay.xmcd D7 3/25/2021