Loading...
HomeMy WebLinkAboutINFRASTRUCTURE PLAN Rev. (1) 8.18.22 - 22-00450 - Friendship Estates - Approx. 154 N 4th E - Plat-Reviewed-Corrections-RequiredAuthor Name Author Email Author Phone No.: Tawnya Grover Tawnya.Grover@rexburg.org 208-372-2167 Joel Gray Joel.Gray@rexburg.org 208-372-2331 Todd Smith Todd.Smith@rexburg.org 208-372-2181 Dale Pickering Dale.Pickering@rexburg.org 2083593020 Description : Friendship Estates - Approx. 154 N 4th E - PlatAddress : 154 N 4th EApplication Type : Document Filename : INFRASTRUCTURE PLAN Rev. (1) 8.18.22 - 22-00450 - Friendship Estates - Approx. 154 N 4th E - Plat.pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference AnnotationType Author : Department Status Page Review Comments Applicant Response Comments 2 OVERALL SITEPLAN Free text Todd Smith : Broadband Open 2 As per Resolution 2022-07, adopted April 6, 2022, newdevelopment is required to follow standards for theinstallation of fiber conduit and distribution boxes. Locationof conduit and distribution boxes need to be identified andshown on plans. 2 OVERALL SITEPLAN Callout Dale Pickering : Fire Open 2 An additional hydrant may be required to provide additionalfire flow. 2 OVERALL SITEPLAN Callout Joel Gray : PW Open 2 Verify 6 ft separation # 22-00450Plat Please digitally re-submit all pages of the plan set in response to requested revisions for our next review cycle, with noted items resolved. Report Date: 08.31.2022 Approval of plans does not constitute approval of variance from code Page 1 of 1 Powered by TCPDF (www.tcpdf.org) File Location:z:\projects\2022\22046 brantley brooks subdivision\3.0 design\3.1 cad\3.13 final\22046 sp cover.dwgPlotted By:russellDate Plotted:Thursday, August 18 2022 at 02:49 PM 1 G-1 COVER I D A H O F A L L S R E X B U R G B L A C K F O O T C H U B B U C K T W I N F A L L S S U N V A L L E Y C A S C A D E M c C A L L B O I S E M O S C O W C O U E R d ' A L E N E R U P E R T S A L M O N A M M O N S T . A N T H O N Y I S L A N D P A R K P O C A T E L L O M O U N T A I N H O M E R I G B Y I O N A S H E L L E Y C I V I L S I T E W O R K F O R : P A R T O F T H E E A S T 1 / 2 O F T H E S O U T H W E S T 1 / 4 O F S E C T I O N 2 0 , T O W N S H I P 6 N O R T H , R A N G E 4 0 E A S T , B O I S E M E R I D I A N , C I T Y O F R E X B U R G , M A D I S O N C O U N T Y , I D A H O A P P R O V E D B Y : C I T Y O F R E X B U R G E N G I N E E R I N G D E P A R T M E N T A P P R O V E D B Y : R O C K Y M O U N T A I N P O W E R A P P R O V E D B Y : C I T Y O F R E X B U R G F I R E D E P A R T M E N T A P P R O V E D B Y : L U M E N A P P R O V E D B Y : I N T E R M O U N T A I N G A S F R I E N D S H I P E S T A T E S N 4TH E MADISON AVE N 3RD E E 1 S T N E 2 N D N R E E D S T AGLE ROCK NGINEERING SURVEYED BY: DRAWN BY: PROJECT NO. APPROVED BY: DESCRIPTIONDATE REVISIONS 1 2 3 4 5 6 ATTENTION This document or any part thereof in detail or design concept is the property of Eagle Rock Engineering and shall not be copied in any form without the written authorization of Eagle Rock Engineering. ESHEET NO. SHEET NAME CIVIL PLANNING SURVEYING IDAHO FALLS (208) 542-2665 REXBURG (208) 359-2665PREPARED FOR: BRANTLEY BROOKS FRIENDSHIP ESTATES SITE PLAN A. SNARR R. JORDAN P.SNARR 22046PRELIM I N A R Y NOT APP R O V E D F O R CONSTR U C T I O N 16410 B T M B O T T O M C B C A T C H B A S I N C O C L E A N - O U T C O N C C O N C R E T E D I A D I A M E T E R E L E V E L E V A T I O N E O E D G E O F O I L F L F L O W L I N E F W F A C E O F W A L K H O R Z H O R I Z O N T A L I F S C I T Y O F R E X B U R G S T A N D A R D S I N V I N V E R T L F L I N E A R F E E T M A X M A X I M U M M H M A N H O L E M I N M I N I M U M M X M A T C H E X I S T I N G O S H A O C C U P A T I O N A L S A F E T Y & H E A L T H A D M I N I S T R A T I O N P C P O I N T O F C U R V A T U R E P T P O I N T O F T A N G E N T P . U . E . P U B L I C U T I L I T Y E A S E M E N T P V C P O L Y V I N Y L C H L O R I D E R E Q ' D R E Q U I R E D M H M A N H O L E S D S T O R M D R A I N S S M H S A N I T A R Y S E W E R M A N H O L E S T A S T A T I O N I N G T B C T O P B A C K O F C U R B T Y P T Y P I C A L V E R T V E R T I C A L V G V A L L E Y G U T T E R X E X I S T I N G X G E X I S T I N G G R O U N D A B B R E V I A T I O N S : D E S C R I P T I O N P R E S S U R E L I N E ( W A T E R L I N E ) S A N I T A R Y S E W E R M A I N L I N E T Y P E F E N C E L I N E O H P O V E R H E A D P O W E R L I N E P R O P O S E D / E X I S T I N G E L E V A T I O N P R O P O S E D / E X I S T I N G F I R E H Y D R A N T P R O P O S E D / E X I S T I N G V A L V E P R O P O S E D / E X I S T I N G C U R B A N D G U T T E R P R O P O S E D / E X I S T I N G S T R E E T L I G H T P R O P O S E D / E X I S T I N G P O W E R P O L E E X I S T . P R O . D E S C R I P T I O N P R O P O S E D / E X I S T I N G M A N H O L E P R O P O S E D / E X I S T I N G S T O R M D R A I N I N L E T P R O P O S E D A S P H A L T D R A I N A G E F L O W A R R O W L E G E N D 0 . 7 5 % B O U N D A R Y L I N E C E N T E R L I N E S E C T I O N L I N E C O N C R E T E E X I S T I N G G R O U N D C O N T O U R 4 7 2 7 8 " W ( 8 " S S T B C 7 2 . 1 0 X G = 7 2 . 1 0 P U B L I C U T I L I T Y E A S E M E N T S T O R M D R A I N M A I N S D GENERAL NOTES:1.UNLESS OTHERWISE SHOWN ON THESE PLANS ALL WORK IS TO BE PERFORMED IN ACCORDANCE TO CURRENT CITY OF REXBURG STANDARDDRAWINGS AND SPECIFICATIONS. THE CONTRACTOR IS REQUIRED TO MAINTAIN A COMPLETE COPY ON SITE AT ALL TIMES (RESOLUTION 2016-15).2.ALL DISTANCES AND DATA SHALL BE CHECKED BY THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. IN CASE OF CONFLICT THE ENGINEERSHALL BE NOTIFIED IMMEDIATELY SO THAT CLARIFICATION MAY BE MADE PRIOR TO THE START OF WORK.3.BASIS OF BEARINGS ARE 2004 CITY GRID.4.ELEVATIONS SHOWN ARE NAVD 88 DATUM TO FINISHED SURFACE OR PIPE INVERT UNLESS OTHERWISE NOTED.5.GENERAL LOCATIONS AND SIZES OF UTILITIES ARE SHOWN ON THE PLANS. THEY ARE TO BE USED FOR GENERAL INFORMATION ONLY. IT IS THERESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE APPROPRIATE UTILITY COMPANIES WHEN CONSTRUCTION MIGHT INTERFERE WITH NORMALOPERATIONS OF ANY UTILITIES. IT SHALL ALSO BE THE CONTRACTORS RESPONSIBILITY TO HAVE THE APPROPRIATE UTILITY COMPANY FIELD-LOCATEANY UTILITY INSTALLATIONS WHICH MIGHT BE AFFECTED BY CONSTRUCTION PRIOR TO BEGINNING WORK IN THAT AREA. THE CONTRACTOR SHALLBE RESPONSIBLE FOR MAINTAINING SERVICE OF EXISTING UTILITIES AND FOR RESTORING ANY UTILITIES DAMAGED DUE TO CONSTRUCTION AT NOADDITIONAL COST TO THE OWNER.6.THE CONTRACTOR SHALL BE RESPONSIBLE FOR SECURING SOURCES FOR GRANULAR MATERIAL, DISPOSAL SITES, AND ANY ADDITIONAL MATERIALTHAT MAY BE NECESSARY FOR PROPER CONSTRUCTION OF THIS PROJECT.7.IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAKE ARRANGEMENTS FOR WATER REQUIRED FOR TESTING, COMPACTION AND DUSTCONTROL MEASURES.8.ROCK EXCAVATION MAY BE ENCOUNTERED DURING UTILITY CONSTRUCTION. EVERY EFFORT WAS MADE TO REDUCE UTILITY DEPTH WHILE STILLMEETING REGULATORY REQUIREMENTS. FOR BIDDING PURPOSES CONTACT OWNER FOR TEST HOLE DEPTH OF ROCK.9.LITTLE DEMOLITION IS REQUIRED ON THIS PROJECT PRIOR TO JOB START. CONTRACTOR/BIDDER TO WALK JOB AND IDENTIFY MINOR DEMOLITIONWORK PRIOR TO BIDDING.10.ALL UTILITY MAIN LINES (WATER, SANITARY SEWER AND STORM DRAINAGE) WITHIN PUBLIC STREETS WILL BE OWNED AND MAINTAINED BY THE CITYAND CONSTRUCTED TO CURRENT CITY OF REXBURG STANDARD DRAWINGS AND SPECIFICATIONS; INSPECTED AND CERTIFIED BY AN ENGINEER,LICENSED IN THE STATE OF IDAHO; AND HAVE “AS-BUILT” DRAWINGS PROVIDED TO THE CITY ENGINEER. FAILURE TO COMPLY WITH THEREQUIREMENTS OF THIS PLAN MAY RESULT IN THE CITY'S WITHHOLDING OF BUILDING PERMITS, CERTIFICATE OF OCCUPANCY, AND WATER ORELECTRICAL SERVICE.11.LANDSCAPING SIGNS NOT TO EXCEED 3 FEET IN HEIGHT IN THE CLEAR SIGHT TRIANGLE.12.THERE SHALL BE A 15-FOOT WIDE PUBLIC UTILITY EASEMENT WITHIN EACH LOT ALONG ALL ROAD/STREET FRONTAGES FOR POWER, PHONE, CABLE,GAS, ETC. (GAS REQUIRES SEPARATE TRENCH). THE EXACT LOCATION OF TRANSFORMERS AND PHONE BOXES WILL BE FIELD DETERMINED BY EACHUTILITY COMPANY AFTER ROADS/STREETS HAVE BEEN CONSTRUCTED TO SUBGRADE AND SIDE SLOPES HAVE BEEN COMPLETED.13.LUMEN/SPARKLIGHT USES THE SAME TRENCH AS ROCKY MOUNTAIN POWER AND REQUIRES CONDUITS (CONTRACTOR SHALL NOTIFY ALL FORSCHEDULING). POWER DESIGN SHOWN IS PRELIMINARY AND ANY CONSTRUCTION STAKING OF POWER SHALL BE CONFIRMED WITH ROCKYMOUNTAIN POWER FOR FINAL LAYOUT. VERIFY CONDUIT SIZE MEETING ROCKY MOUNTAIN POWER DESIGN PRIOR TO CONSTRUCTION.14.ALL UTILITIES INCLUDING POWER, PHONE, CABLE, ETC. EXCEPT NATURAL GAS MAY BE IN THE SAME TRENCH. NATURAL GAS MUST BE IN A SEPARATETRENCH.15.A 12” SPACING SHALL BE REQUIRED BETWEEN DIFFERENT UTILITIES IN THE SAME TRENCH.16.CONTRACTOR SHALL CONTACT DIG-LINE AT 811, (800) 342-1585 OR (208) 342-1585 PRIOR TO ANY UTILITY CONSTRUCTION.WATER NOTES:1.ALL WATER MAINS, SERVICES, AND ALL APPURTENANCES SHALL MEET CURRENT CITY OF REXBURG STANDARD DRAWINGS AND SPECIFICATIONS. THISSHALL INCLUDE ALL MATERIALS, LABOR, AND INSTALLATION INCLUDING VERTICAL AND HORIZONTAL SEPARATION DISTANCES AND SLOPEREQUIREMENTS.2.ALL WATER MAIN LINE SHALL BE CLASS 50 DUCTILE IRON MEETING AWWA C-151.3.MINIMUM COVER OVER ALL WATER LINES SHALL BE 6 FEET.4.WATER LINE SHALL HAVE A MINIMUM SEPARATION DISTANCE OF TEN (10) FEET FROM ANY SANITARY SEWER OR STORM SEWER MEASURED FROMTHE OUTSIDE OF EACH PIPE AS OUTLINED IN THE ISPWC 2020 STANDARD DRAWING SD-407. CROSS AT APPROXIMATELY RIGHT ANGLES WITH FULLPIPE SECTIONS AND MINIMUM OF 1.5 FEET OF VERTICAL SEPARATION.5.THRUST BLOCKS SHALL BE PLACED AT ALL DIRECTION CHANGES FOR PRESSURE PIPE.6.FIRE HYDRANTS SHALL HAVE TWO 2-1/2” DIAMETER HOSE NOZZLES AND ONE 4-1/2” DIAMETER HOSE NOZZLE PER CITY STANDARDS.7.WATER AND SEWER SERVICE LINES ARE SHOWN AT APPROXIMATE LOCATIONS. CONTRACTOR TO CONTACT DIG LINE PRIOR TO ALL EXCAVATION ANDFIELD VERIFY LOCATION AND WITH ARCHITECTURAL DRAWINGS (IF APPLICABLE) FOR ANY ADDITIONAL SERVICES REQUIRED.8.WATER METERS AND PRESSURE REDUCING VALVES - SEE PLUMBING DRAWINGS FOR DETAILS. ALL PLUMBING SHALL MEET THE STATE OF IDAHOPLUMBING CODE. COMMERCIAL BUILDINGS SHALL REQUIRE THE WATER METERS TO BE INSTALLED ON THE INTERIOR AND MOUNTED IN AHORIZONTAL POSITION WITHIN A HEATED MECHANICAL ROOM.9.CONTRACTOR SHALL INSTALL FIRE LINES/SPRINKLERS MEETING THE CURRENT VERSION OF THE INTERNATIONAL FIRE CODE AND SHALL INCLUDE ALLAPPURTENANCES (IF APPLICABLE).10.IT IS THE RESPONSIBILITY OF THE OWNER TO PROVIDE AND INSTALL ALL REQUIRED BACKFLOW PREVENTION DEVICES ON WATER SERVICES.11.ALL WATER MAINS AND APPURTENANCES SHALL BE TESTED FOR PRESSURE, LEAKAGE, AND BACTERIA MEETING CITY AND AWWA STANDARDS ANDSHALL BE CLEANED AND DISINFECTED PRIOR TO ACCEPTANCE BY THE CITY FOR DOMESTIC USE. TESTING AND DISINFECTION OF WATER MAINS ANDAPPURTENANCES SHALL BE IN ACCORDANCE WITH AWWA C651 STANDARDS. AWWA STANDARDS REQUIRE EACH STREET TO BE TESTEDINDIVIDUALLY FOR PRESSURE, LEAKAGE, AND BACTERIA.SANITARY SEWER NOTES:1.ALL SEWER MAIN SHALL BE PVC SDR 35 IN ACCORDANCE WITH ASTMD3034 WATER MAIN AND SERVICE SHALL MEET CURRENT CITY OF REXBURGSTANDARD DRAWINGS AND SPECIFICATIONS. THIS SHALL INCLUDE ALL MATERIALS, LABOR, AND INSTALLATION INCLUDING VERTICAL ANDHORIZONTAL SEPARATION DISTANCES AND SLOPE REQUIREMENTS.2.SEPARATION REQUIREMENTS: WATER LINE SHALL HAVE A MINIMUM SEPARATION DISTANCE OF TEN (10) FEET FROM ANY SANITARY SEWER ORSTORM SEWER MEASURED FROM THE OUTSIDE OF EACH PIPE AS OUTLINED IN THE ISPWC 2020 STANDARD DRAWING SD-407. CROSS ATAPPROXIMATELY RIGHT ANGLES WITH FULL PIPE SECTIONS AND MINIMUM OF 1.5 FEET OF VERTICAL SEPARATION.3.CONTRACTOR SHALL PERFORM TESTING AND CLEANING OF SEWER MAINS MEETING CITY STANDARDS. S H E E T I N D E X S H E E T N o . S H E E T D E S C R I P T I O N S H E E T T I T L E 1 G - 1 C O V E R 2 C - 1 O V E R A L L S I T E P L A N 3 P P - 1 P L A N & P R O F I L E A u g u s t 2 0 2 2 V I C I N I T Y M A P ELECTRICAL NOTES:1.ALL NEW ELECTRICAL FACILITIES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE CURRENT ROCKY MOUNTAIN POWER SERVICE POLICY.2.DEVELOPER SHALL BEAR ALL COSTS TO RELOCATE OR REMOVE EXISTING POWER POLES, LIGHT POLES, ANCHOR GUYS AND MISCELLANEOUS ELECTRICAL FACIL I T I E S . 3.ALL PVC ELECTRIC CONDUITS SHALL BE PVC SCHEDULE 40. ALL FIBERGLASS CONDUITS SHALL MEET ROCKY MOUNTAIN POWER'S MARKING AND STRENGTH RA T I N G R E Q U I R E M E N T S . C O N D U I T D I A M E T E R S S H A L L M E E T R O C K Y M O U N T A I N P O W E R ' S DESIGN. ALL ELBOWS SWEEP RADII SHALL BE 36”, 48” OR 60” DEPENDING ON ROCKY MOUNTAIN POWER'S DESIGN.4.ALL PRIMARY AND SECONDARY CONDUITS SHALL BE PROVIDED AND INSTALLED BY THE DEVELOPER.5.TRENCH EXCAVATION AND CONDUIT PLACEMENT SHALL BE IN ACCORDANCE WITH ROCKY MOUNTAIN POWER SERVICE POLICY SPECIFICATIONS AND IN ACCO R D A N C E W I T H O S H A S T A N D A R D S . C O N D U I T T R E N C H D E P T H S S H A L L B E B E T W E E N 3 6 ” AND 48” (NOT TO EXCEED 60”) AND INCLUDE THE REQUIRED SAND PLACEMENT BELOW AND ABOVE THE PLACED CONDUIT.6.THE ENGINEER SHALL PROVIDE ALL STAKING AND LAYOUT OF NEW ELECTRICAL FACILITIES INCLUDING POWER POLES.7.THE CONTRACTOR SHALL RETAIN AND PROTECT ALL EXISTING POWER POLES AND ELECTRICAL FACILITIES DURING CONSTRUCTION.8.THE DEVELOPER SHALL COORDINATE ALL ELECTRICAL CONSTRUCTION WITH ROCKY MOUNTAIN POWER.9.CLEARANCE BETWEEN OVERHEAD POWER AND NEW BUILDING STRUCTURES SHALL BE MAINTAINED MEETING THE CURRENT ROCKY MOUNTAIN POWER SER V I C E P O L I C Y . 10.SEE ROCKY MOUNTAIN POWER ELECTRICAL SITE PLAN FOR OFF-SITE AND ON-SITE ELECTRICAL LAYOUT AND INSTALLATION DETAILS. IN THE EVENT THE FIBER O P T I C U T I L I T Y E L E C T S T O U S E T H E S A M E T R E N C H , T H E Y M U S T M E E T N E S C UNDERGROUND UTILITY CLEARANCES.11.A 15 FOOT WIDE PUBLIC UTILITY EASEMENT IS PERPETUALLY RESERVED WITHIN EACH LOT ALONG ALL ROAD FRONTAGES FOR THE USE OF PUBLIC UTILITIES W I T H I N T H I S S U B D I V I S I O N . N O P E R M A N E N T S T R U C T U R E S , S I D E W A L K S , A N D D R I V E W A Y S SHALL BE CONSTRUCTED OVER SAID EASEMENT (OTHER THAN CROSSINGS) IN ORDER FOR THE UTILITY COMPANIES TO MAINTAIN. EA S T 2 N D N O R T H NORTH 4TH EASTHOUSE C O R P O F T H E P R E S I D I N G I N S T R U M E N T N o . 1 3 6 3 7 3 S 8 9 ° 4 4 ' 5 8 " W 2 3 0 . 0 0 ' N 8 9 ° 4 4 ' 5 8 " E 2 3 0 . 0 0 ' N0°15'02"W 130.43'15000 SF0.115 AC. 6 5 0 0 0 S F 0 . 1 1 5 A C . 5 5 0 0 0 S F 0 . 1 1 5 A C . 4 5 0 0 0 S F 0 . 1 1 5 A C . 35000 SF0.115 AC.25000 SF0.115 AC. S0°15'02"E 130.43' SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD O H P OHPOHPOHPOHPOHPOHP O H P SS SS SS SS SS X X X X X X X X X X X X X X X X X X X X X X X W W W W W W W W W W W W W WWWWWWWWWWWWWWWWWWWWWWW W W W(8''SS (8''SS (8''SS (8''SS (8''SS (8''SS (8''SS (8''SS(8''SS(8''SS(8''SS(8''S S ( 8 ' ' S S ( 8 ' ' S S ( 8 ' ' S S ( 8 ' ' S S 112 TIE NEW SIDEWALK INTO EXISTING(MATCH EXISTING GRADE)7'' 1 2 1 2 1 2 1 2 2SSMH 1EX. SSMH SSMH 2 S S M H 3 1 1 11 4 8 7 3 4874 4873 4 8 7 2 4872 487248744873File Location:z:\projects\2022\22046 brantley brooks subdivision\3.0 design\3.1 cad\3.13 final\22046 sp overall site plan.dwgPlotted By:russellDate Plotted:Thursday, August 18 2022 at 02:49 PM W E S N 0 2 0 ' 2 0 ' 1 0 ' S C A L E : 1 " = 2 0 ' 2 C-1 OVERALL SITE PLAN AGLE ROCK NGINEERING SURVEYED BY: DRAWN BY: PROJECT NO. APPROVED BY: DESCRIPTIONDATE REVISIONS 1 2 3 4 5 6 ATTENTION This document or any part thereof in detail or design concept is the property of Eagle Rock Engineering and shall not be copied in any form without the written authorization of Eagle Rock Engineering. ESHEET NO. SHEET NAME CIVIL PLANNING SURVEYING IDAHO FALLS (208) 542-2665 REXBURG (208) 359-2665PREPARED FOR: BRANTLEY BROOKS FRIENDSHIP ESTATES SITE PLAN A. SNARR R. JORDAN P.SNARR 22046PRELIM I N A R Y NOT APP R O V E D F O R CONSTR U C T I O N 16410 15' P.U.E. (TYP.) G A S K E T A L L J O I N T S C O N C R E T E C O L L A R F I N I S H E D G R A D E F R A M E & C O V E R 4 5 ° F L O W S H E L F S H E L F S H E L F M A N H O L E N O T E S : 5 " F L E X I B L E R U B B E R G A S K E T P R E C A S T M O N O L I T H I C C O N C E N T R I C C O N E S E C T I O N P R E C A S T C O N C R E T E M A N H O L E - B A R R E L S E C T I O N S A S R E Q ' D P R E F A B R I C A T E D B A S E . U N D I S T U R B E D E A R T H A 4 APPROVED BEDDING 6 " M I N 31" 4 8 " D I A 9 MIN R U B B E R B O O T .75 X Di PIPE 1 . P L A C E V E R T I C A L W A L L O N U P S T R E A M S I D E O F M A N H O L E , R O T A T E D 4 5 D E G R E E S . 2 . W H E R E P V C P I P E I S U T I L I Z E D , I N S T A L L A R U B B E R R I N G O R G A S K E T C O L L A R W H E R E T H E P I P E I S I N C O N T A C T W I T H M A N H O L E B A S E A N D / O R M A N H O L E C H A N N E L , I N O R D E R T O I N S U R E A W A T E R T I G H T S E A L . 3 . U N L E S S O T H E R W I S E S H O W N , M A N H O L E S S H A L L H A V E 0 . 1 F A L L F R O M U P S T R E A M I N V E R T T O D O W N S T R E A M I N V E R T . F O R P I P E S L O P E S G R E A T E R T H A N 2 . 5 % S L O P E , S E E P L A N & P R O F I L E . P L A N D E T A I L N O T T O S C A L E S E W E R M A N H O L E S E C T I O N 1 N O T T O S C A L E T Y P I C A L S E W E R T R E N C H D E T A I L 2 1 2 " ( M I N . ) U N D I S T U R B E D E A R T H ( T Y P . ) E X I S T I N G B A S E F O U N D A T I O N S T A B I L I Z A T I O N T Y P E I B E D D I N G M A T E R I A L P I P E T R E N C H B A C K S L O P E P E R O . S . H . A . O R S U I T A B L E S H O R I N G . U P P E R & L O W E R B A C K F I L L Z O N E M A T E R I A L & C O M P A C T I O N T O M A T C H R E Q U I R E M E N T S O F S T O R M D R A I N T R E N C H S E C T I O N ( D E T A I L 1 / S D - 1 ) . L O W E R B A C K F I L L Z O N E . M A T E R I A L & C O M P A C T I O N T O M A T C H R E Q U I R E M E N T S O F L O W E R B A C K F I L L Z O N E O F S T O R M D R A I N P I P E S E C T I O N . D E T A I L ( 1 / S D - 1 ) . F I N I S H G R A D E S U R F A C E R E P A I R W I D T H O R L O C A L C U T B A C K R E Q U I R E M E N T S T Y P I C A L B O T H S I D E S . E X I S T I N G S U R F A C E N E W P A V E M E N T S E C T I O N D o + 2 4 " SEE NOTE 2 VARIES PER PIPE SIZE 2'-6" VARIES 0.35' MIN 0.54' MIND o S U B G R A D E O R N A T U R A L G R O U N D L I D & C O V E R 1 . G A L V A N I Z E D S T A N D P I P E 3 2 I N C H E S W R A P P E D W I T H T A P E . 2 . A L L S E R V I C E L I N E S S H A L L B E B O R E D U N D E R E X I S T I N G A S P H A L T P A V I N G . N O A S P H A L T P A V I N G S H A L L B E C U T F O R S E R V I C E L I N E I N S T A L L A T I O N . 3 . A L L S U P P L I E S P R O V I D E D B Y C I T Y E X C E P T C O R P O R A T I O N C U R B S T O P , M E T E R S U P P O R T , S U P P L Y L I N E S I N & O U T . G E N E R A L N O T E S : 4"L A W N L E V E L M E T E R T O U C H R E A D B U T T O N S E R V I C E L I N E M E T E R S U P P O R T S T R A P S E R V I C E L I N E T O M E T E R S U P P O R T 2 " M I N H O U S E S I D E G A L V A N I Z E D P I P E , C O N N E C T T O M E T E R & A N G L E M E T E R V A L V E W / A P P R O X I M A T E F I T T I N G S S E E N O T E 1 2 0 " X 4 8 " P O L Y B A R R E L 2 0 " R I N G A N D C O V E R W / T O U C H R E A D H O L E B A L L T Y P E C O R P O R A T I O N A N D C U R B S T O P A D A P T E R , P O L Y - B Y - F E M A L E M E T A L P I P E R A T E D A T 3 0 0 P S I M I N I M U M W O R K I N G P R E S S U R E . N O T T O S C A L E 1 " M E T E R A N D M E T E R S E T T I N G D E T A I L ( S E E C I T Y O F R E X B U R G S T A N D A R D D R A W I N G 1 5 ) 3 SEWER MANHOLE SEE STANDARD MA N H O L E D E T A I L 1 . C O V E R M U S T SAY "CITY OF REXBURG AND CONFINE D S P A C E E N T R Y " 4" SANITARY SEWER SERVICE GENERAL NOTESSEWER CONSTRUCTION NOTES12 W A T E R C O N S T R U C T I O N N O T E S 1 I N S T A L L 1 " W A T E R S E R V I C E P E R C I T Y O F R E X B U R G S T A N D A R D D R A W I N G S A N D S P E C I F I C A T I O N S . OVERALL SITE INSTALL 5' SIDEWALK PER CITY OF REXBURG STANDARDS.(4" THICK WITH A 6" BASE COARSE MINIMUM)1INSTALL SANITARY SEWER CLEAN-OUT3TREE LINE (TYP.) REMOVE TREES ASNECESSARY FOR SS INSTALLATION Verify 6 ft separation An additional hydrant may be required to provide additional fire flow. A s p e r R e s o l u t i o n 2 0 2 2 - 0 7 , a d o p t e d A p r i l 6 , 2 0 2 2 , n e w d e v e l o p m e n t i s r e q u i r e d t o f o l l o w s t a n d a r d s f o r t h e i n s t a l l a t i o n o f f i b e r c o n d u i t a n d d i s t r i b u t i o n b o x e s . L o c a t i o n o f c o n d u i t a n d d i s t r i b u t i o n b o x e s n e e d t o b e i d e n t i f i e d a n d s h o w n o n p l a n s . 4864 4866 4868 4870 4872 4874 4 8 6 4 4 8 6 6 4 8 6 8 4 8 7 0 4 8 7 2 4 8 7 4 0+001+00 1 + 5 0 8" E INV IN=4865.858" S INV OUT=4865.75 EX. SSMHSTA=0+07.08, 51.81' LRIM=4873.008" N INV IN=4866.168" W INV OUT=4866.06 SSMH 1STA=0+13.83, 0.00'RIM=4872.50EX. 128-LF OF 8" PVC @ 0.40%52-LF OF 8" PVC @ 0.40%125-LF OF 8" PVC @ 0.40%8" E INV IN=4866.768" S INV OUT=4866.66 SSMH 2STA=1+39.24, 0.00' RRIM=4871.80 EXISTING GRADE(CORE INV)(MATCH TBW GRADE)(MATCH NEW TBW GRADE)NORTH 4TH EASTN0°15'02"W 130.43' S D S D O H P O H P O H P O H P SSSS W W W W W W W W W W W W W W W W W (8''SS(8''SS(8''SS(8''SS(8''SS(8''SS(8''SS ( 8 ' ' S S 0+001+00 1 + 5 0 0+00 E A S T 2 N D N O R T H 121 23.82' 2 4 . 6 2 ' 1 1 . 2 8 ' SSMH 1 SSMH 2 EX. SSMH15' P.U.E. (TYP.)1 CONNECT NEW 8" SS LINE TO EXISTING SSMH E A S T 2 N D N O R T H N 8 9 ° 4 4 ' 5 8 " E 2 3 0 . 0 0 ' O H P O H P O H P O H P O H P O H P O H P O H P X X X X W W W W W W W W W W W W W W W W W W W W W W W (8''SS ( 8 ' ' S S ( 8 ' ' S S ( 8 ' ' S S ( 8 ' ' S S ( 8 ' ' S S ( 8 ' ' S S ( 8 ' ' S S ( 8 ' ' S S ( 8 ' ' S S 1 2 T I E N E W S I D E W A L K I N T O E X I S T I N G ( M A T C H E X I S T I N G G R A D E ) 1 2 1 2 1 2 1 2 S S M H 2 1+50 0 + 0 0 1 + 0 0 2 + 0 0 2 + 4 0 S S M H 3 1 1 1 4 8 6 4 4 8 6 6 4 8 6 8 4 8 7 0 4 8 7 2 4 8 7 4 0 + 0 0 1 + 0 0 2 + 0 0 8 " E I N V I N = 4 8 6 6 . 7 6 8 " S I N V O U T = 4 8 6 6 . 6 6 S S M H 2 S T A = 0 + 1 0 , 0 . 0 0 ' L R I M = 4 8 7 1 . 8 0 2 1 5 - L F O F 8 " P V C @ 0 . 4 0 % 8 " W I N V O U T = 4 8 6 7 . 6 2 S S M H 3 S T A = 2 + 2 5 . 0 7 , 0 . 0 0 ' R I M = 4 8 7 1 . 5 0 E X I S T I N G G R A D E ( M A T C H T B W G R A D E ) ( M A T C H T B W G R A D E ) 1 I N S T A L L 1 " W A T E R S E R V I C E P E R L A T E S T R E V I S I O N O F I S P W C S T A N D A R D D E T A I L D R A W I N G S S D - 4 0 1 ( T Y P ) INSTALL 5' SIDEWALK PER CITY OF REXBURG STANDARDS.(4" THICK WITH A 6" BASE COARSE MINIMUM)1File Location:z:\projects\2022\22046 brantley brooks subdivision\3.0 design\3.1 cad\3.13 final\22046 sp overall site plan.dwgPlotted By:russellDate Plotted:Thursday, August 18 2022 at 02:49 PM 3 PP-1 PLAN & PROFILE AGLE ROCK NGINEERING SURVEYED BY: DRAWN BY: PROJECT NO. APPROVED BY: DESCRIPTIONDATE REVISIONS 1 2 3 4 5 6 ATTENTION This document or any part thereof in detail or design concept is the property of Eagle Rock Engineering and shall not be copied in any form without the written authorization of Eagle Rock Engineering. ESHEET NO. SHEET NAME CIVIL PLANNING SURVEYING IDAHO FALLS (208) 542-2665 REXBURG (208) 359-2665PREPARED FOR: BRANTLEY BROOKS FRIENDSHIP ESTATES SITE PLAN A. SNARR R. JORDAN P.SNARR 22046PRELIM I N A R Y NOT APP R O V E D F O R CONSTR U C T I O N 16410 SEWER MANHOLE SEE STANDARD MA N H O L E D E T A I L 1 . C O V E R M U S T SAY "CITY OF REXBURG AND CONFINE D S P A C E E N T R Y " 4" SANITARY SEWER SERVICE GENERAL NOTESSEWER CONSTRUCTION NOTES12 W A T E R C O N S T R U C T I O N N O T E S INSTALL SANITARY SEWER CLEAN-OUT3WESN020'20'10'SCALE: 1" = 20' W E S N 0 2 0 ' 2 0 ' 1 0 ' S C A L E : 1 " = 2 0 ' NORTH 4TH EAST 1 5 ' P . U . E . ( T Y P . ) NORTH 4TH EAST SS LINE E A S T 2 N D N O R T H S S L I N E