HomeMy WebLinkAboutCODE REVIEW - 22-00795 - Madison Station Apartments - Bldg 1 Code Review #870 Madison Station CODE REVIEW Date September 25, 2022 Building Code 2018 IBC 12-plex, 3 story apartment building General Information: Project Title Madison Station Apartments Address Trejo Rexburg Madison Idaho (street) (city) (county) (state) 1. Occupancy Group (Section 302): a. 1st Floor Level: R-2 b. 2nd Floor Level: R-2 c. 3rd Floor Level: R-2 2. Separation Walls (Section 420.2): Dwelling Units Separated by Fire Partition 3. Type of Construction (Section 602): V-B 4. Allowable Height, Stories & Floor Areas (Table 504.3/504.4) Allowable Actual Building Height (13R sprinkled) 60 ft 39 ft Building Stories (13R sprinkled) 4 stories 3 stories 5. Allowable Floor Area (Table 506.2) Allowable Actual Permitted floor area (per level) Unlimited 13,440 Frontage area increase 0% 0% Fire sprinkler area increase 0% 0% Total Allowable Area (per floor): Unlimited sf 13,440 sf 6. Required Fire Separation based on Occupancy (Table 508.4) Occupancy Separation: N/A 7. Incidental Use Separation (Table 509) Furnace over 400,000 Btu/hr N/A Boiler over 15 psi & 10 hp N/A Laundry / Storage over 100 sf N/A 8. Fire-Resistance Rating Requirements for Building Elements (Table 601) Construction Type V-B Primary Structure: 0 hour Bearing Walls Exterior 0 hour (see Table 602) Interior 0 hour Non-Bearing Walls Exterior (Table 602) Interior 0 hour Floor / Ceiling Structure 0 hour Roof Structure 0 hour 9. Non-Bearing Exterior Walls (Table 602), Type VB X<5’ 1 hour, 5<X<10’ 1 hour, 10<X<30’ 0 hour, X>30’ 0 hour Code Review #870 Madison Station 10. Maximum Area of Ext. Wall Opening Based on Fire Sep. Distance (Table 705.8): Distance Non-Protected / Non-Sprinkled (13R) 0 to > 3’ Not Permitted 3 to 5’ Not Permitted 5 to 10’ 10% 10 to 15’ 15% 15 to 20’ 25% 20 to 25’ 45% 25 to 30’ 70% 30 or Greater No Limit 11. Fire Wall Fire-Resistance Ratings (Table 706.4): R-2, 3-Hour (N/A) 12. Fire Barrier Fire-Resistance Ratings (Table 707.3.10): R, 2-hour (N/A) 13. Fire Partition Fire-Resistance Ratings (Section 708.3 & Table 1020.1): All: 1 hour Corridor: R, 0.5-hour w/ 13R 14. Fire Rated Door / Glazing (Table 716.1(2) & 716.1(3)) 1/2-Hour Fire Partition/Corridor: 20 Minute Door 20 Minute Window, OH-20 or W-60 15. Fire Damper Ratings (Table 717.3.2.1): >3-Hour rated assembly: 3 Hours <3-Hour rated assembly: 1 ½ Hour 16. Draft stop in floor/ceiling assembly (718.3): Not to exceed 1,000 sf Draft stop in attic (718.4): Not to exceed 3,000 sf 17. Occupant Load – Exiting (Table 1004.5) a. Occupant for every 200 gross sf (13,400/200) = 67 Per Bldg. 18. Spaces with 1-Exit or Exit Access (Table 1006.2.1) R-2 Common Path of Egress, 125 lf. Max Occupancy for 1 exit; 20. 2 Exits Req’d. 19. Number of Exits (Table 1006.3.3(1)) R-2, maximum of 4 dwelling units, Max CPoE 125 lf. 2 Exits Req’d. 20. Single Exits (Table 1006.3.3(2)) R-2, maximum occupants of 10, Max CPoE 75 lf. 2 Exits Req’d. 20. Egress Width: Required Actual Stairs (Section 1005.3.1) (0.3 x 67) = 20” Req’d 60” Aisles/Doors (Section 1005.3.2) (0.2 x 67) = 14’’ Req’d 78” total egress width 21. Exit Travel Distance (Table 1017.2) Allowed Actual Maximum Travel (‘E’ Occupancy) 250’ 222’ 22. Corridor Rating (Table 1020.1): Group “R”, occupant load 67>10, 1/2-hour fire rating. 23. Fire Suppression System: 13R 24. Fire Alarms: Yes Code Review #870 Madison Station 25. Parking Required: Units x Factor Required Provided 1-Bedroom Units (240 x 1.5) = 360 Stalls 360 Stalls 2-Bedroom Units (120 x 2) = 240 Stalls 243 Stalls Totals: 600 Stalls 603 Stalls END OF DOCUMENT