Loading...
HomeMy WebLinkAboutREDLINED SITE PLAN - 21-00577 - Storage 1910 - Bldg 1Author Name Author Email Author Phone No.: Stan Crittenden Stan.Crittenden@rexburg.org 208-372-2314 Cody Jones Cody.Jones@rexburg.org 208-372-2173 Description : 4550 S 3300 W - Storage Units Address : 4550 S 3300 W Application Type : Document Filename : Storage 1910-THORNTON STORAGE 6-17-21[10573].pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments 4 SITE PLAN Free text Cody Jones : Building Open 4 As per table 602: A IIB building classified as a S1 occupancy type, with less then 10' separation distance requires a 1 hour exterior wall. 4 SITE PLAN Free text Stan Crittenden : Fire Open 4 International fire code requires that the fire department be able to park and reach anywhere on the building with a 150' hose. IFC 503.1.1 4 SITE PLAN Free text Stan Crittenden : Fire Open 4 IFC 2018 appendix B requires a IIB construction type building with a square footage of 4,600 sq.ft. to have a water source that can supply 1,500 gpm. for fire suppression efforts. See Table B105.1(2) # 21-00577 Madison County - Commercial Report Date: 08.10.2021 Approval of plans does not constitute approval of variance from code Page 1 of 1 Powered by TCPDF (www.tcpdf.org) SITE MAP VICINITY MAP Date: Connect Engineering APPROVAL SIGNATURES: of DEVELOPMENT DRAWINGS FOR: STATE MAP SHEET NO. PLOT DATE: 6/17/2021 11:46 AM Date: The Civil Connection 1150 Hollipark Dr. Idaho Falls, ID 83401 208.881.0081 1 6 THORNTON STORAGE THORNTON, ID MADISON COUNTY THORNTON, ID N0 ° 0 6 ' 5 3 " E 48 6 . 2 5 ' S89° 59' 05"E 354.02' L =6 0 2 .2 8 ' R =5 2 9 5 .0 0 ' D =6 °3 1 '0 2 " C =S 3 6 °0 8 '1 4 "W N0 ° 0 6 ' 5 3 " E 48 6 . 2 5 ' S89° 59' 05"E 354.02' L =6 0 2 .2 8 ' R =5 2 9 5 .0 0 ' D =6 °3 1 '0 2 " C =S 3 6 °0 8 '1 4 "W -2 . 0 3 % -2 . 4 3 % -3.47% -2.20% -2 . 3 2 % -2 . 3 4 % -2.2 6 % -2. 9 4 % -3.47% -2 . 8 1 % -2.02% -2 . 7 3 % -0.22% -0.20% -1. 1 3 % -0. 4 4 % -0.22% -0.21% -2 . 7 6 % - 3 . 3 5 % - 3 . 2 1 % -3 . 1 2 % -3.44% -3 . 3 5 % -3.86% 48 5 6 4856 FG: 4855.83 FG: 4855.83 FG: 4855.83 FG: 4855.88-0 . 5 0 % -0 . 9 0 % -2. 2 0 % FF: 4856.00 FF: 4856.00 FF: 4856.00 FF: 4856.00 4855.33 GRATE 4855.34 GRATE 4855.23 GRATE 4855.21 GRATE 4855.45 GB 4855.37 GB 4855.54 GB 4855.49 GB 4856.01 EXIST BOUNDARY EL. 4855.10 EXIST BOUNDARY EL. 4854.23 EXIST BOUNDARY EL. 4854.86 EXIST BOUNDARY EL. 4853.95 EXIST BOUNDARY EL. 4854.81 EXIST BOUNDARY EL. FG: 4855.83 FG: 4855.83 FG: 4855.83 FG: 4855.83 4 8 5 5 FG: 4855.83 FG: 4855.83 FG: 4855.83 FG: 4855.83 FG: 4855.83 FG: 4855.83 FG: 4855.83 FG: 4855.83 FG: 4855.83 FG: 4855.83 4854.00 BTM 4854.00 BTM 48 5 5 4854.45 EXIST BOUNDARY EL. CHECK BY SHEETS DRAWN BY JOB NO: DATE: OF SHEET BDJTT SH E E T N A M E : PR O J E C T : LO C A T I O N : 2020-134 DATE:DATE: June 17, 2021 DA T E RE V I S I O N S CL I E N T : Th e C i v i l C o n n e c t i o n 11 5 0 H o l l i p a r k D r . I d a h o F a l l s , I D 8 3 4 0 1 20 8 . 8 8 1 . 0 0 8 1 PRELIMINARY FOR REVIEW ONLY 4 6 TH O R N T O N S T O R A G E SI T E P L A N TH O R N T O N , I D INSTALL INFILTRATION CATCH BASIN DETAIL PER SHEET 3602-3 140.00' 20 . 0 0 ' 20.00' 230.00' 20 . 0 0 ' 2 0 . 0 0 ' 110 . 0 0 ' 160.00' 50 . 0 0 ' 30 . 0 0 ' 602-3 602-3 602-3 602-3 29.94' 2 6 . 2 5 ' 20.00' 60 . 0 0 ' 24 . 9 9 ' 41 . 6 8 ' EX I S T I N G B U I L D I N G EXISTING BUILDING 100-1 100-1 RETAIN AND PROTECT100-1 FF: 4855.56 FF: 4856.88 4" DEPTH CRUSHED 3 4" MINUS AGGREGATE LEVELING COURSE COMPACTED TO 95% ASTM D698 12" DEPTH UNCRUSHED AGGREGATE SUBBASE COURSE COMPACTED TO 95% ASTM D698 SUBGRADE EARTH COMPACTED TO 95% ASTM D698 DRIVE AISLE SECTION 8.77 ft 6. 4 4 f t As per table 602: A IIB building classified as a S1 occupancy type, with less then 10' separation distance requires a 1 hour exterior wall. International fire code requires that the fire department be able to park and reach anywhere on the building with a 150' hose. IFC 503.1.1 IFC 2018 appendix B requires a IIB construction type building with a square footage of 4,600 sq.ft. to have a water source that can supply 1,500 gpm. for fire suppression efforts. See Table B105.1(2)