HomeMy WebLinkAboutPLANS - 22-00794 - 80 K St - Solar PanelsADDITIONAL NOTES P L A N S E T L E G E N D S H E E T I N D E X V I C I N I T Y M A P A P P L I C A B L E C O D E S A B B R E V I A T I O N S P R O J E C T I N F O R M A T I O N OCCUPANCY: R-3CONSTRUCTION TYPE: V-BUNSPRINKLERED ALL CONDUIT TO RUN ON EXTERIOR OF HOUSE UNLESSOTHERWISE NOTED P V - 1 P R O J E C T I N F O R M A T I O N , V I C I N I T Y M A P P V - 2 S I T E P L A N , A E R I A L V I E W P V - 3 E L E C T R I C A L L I N E D I A G R A M A N D N O T E S P V - 4 R E Q U I R E D S I G N A G E PROJECT INFORMATION, VICINITY MAP ISSUED FOR: PERMIT DATE 10/08/2022 www.bigdogenergy.com SOLAR PHOTOVOLTAIC SYSTEM DARIAN BESS DESIGNED BY CONTRACTOR INFORMATION P V - 1 80, K ST., REXBURG, ID 83440 BIG DOG RENEWABLE ENERGY CONTRACTOR LIC #: IDAHO #017916 620 PHEASANT RIDGE DR CHUBBUCK, ID 83202 208-242-3352 T 208-232-5935 F X__________________ ( E ) E X I S T I N G ( N ) N E W E X T E X T E R I O R I N T I N T E R I O R E M T E L E C T R I C A L M E T A L L I C T U B I N G R M T R I G I D M E T A L L I C T U B I N G F M C F L E X I B L E M E T A L L I C C O N D U I T V O C V O L T A G E O P E N C I R C U I T V M P V O L T A G E A T M A X . P O W E R I S C S H O R T C I R C U I T C U R R E N T I M P C U R R E N T A T M A X . P O W E R N T S N O T T O S C A L E MSPSUBACDCSLCMINVJBCBBAT M A I N S E R V I C E P A N E L S U B S E R V I C E P A N E L A C D I S C O N N E C T D C D I S C O N N E C T S O L A R L O A D C E N T E R M O N I T O R I N G M E T E R I N V E R T E R J U N C T I O N B O X C O M B I N E R B O X B A T T E R Y P V P R O D U C T I O N M E T E R R A P I D S H U T D O W N I N T I T I A T O R PMRSI D A R I A N B E S S 8 0 K S T . , R E X B U R G , I D 8 3 4 4 0 1 4 - U R E F B M 4 0 0 M F G - B B ( 4 0 0 W ) P H O T O V O L T A I C M O D U L E S 1 4 - E N P H A S E I Q 8 P L U S - 7 2 - 2 - U S ( 2 9 0 W ) I N V E R T E R ( S ) S Y S T E M S I Z E : 5 . 6 0 0 K W D C S T C A R R A Y A R E A : 2 9 4 . 6 2 S F 1. ALL MODULES WILL BE GROUNDED IN ACCORDANCE WITHTHE CODE AND THE MANUFACTURES INSTALLATIONINSTRUCTIONS.2. ALL PLACARDS REQUIRED BY NEC 2017 CODE MACHINEPRINTED LETTERS IN A CONTRASTING COLOR TO THEPLACARD.3. LIQUID TIGHT FLEXIBLE CONDUIT SHALL BE SUNLIGHTRESISTANT.4. ELECTRICAL INSTALLATION WILL COMPLY WITH NEC 2017CODE.5. ALL SOLAR MODULES EQUIPMENT AND METALLICCOMPONENTS ARE TO BE BONDED.6. ALL PLUMBING AND MECHANICAL ROOF VENTS TO CLEARFROM PHOTOVOLTAIC ARRAY, OR EXTEND ABOVE SOLARPANELS.7. SOLAR PHOTOVOLTAIC SYSTEM TO BE INSTALLED ONRESIDENTIAL STRUCTURE.8.9.10.DESIGN COMPLYING WITH THE IBC 2018 CODE AND ALL LOCAL ORDINANCES AND POLICIES.THE PROJECT HAS BEEN DESIGNED TO WITHSTAND A MINIMUM 115 MPH WIND LOAD.THE SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND A UTILITY IS OBTAINED.11. IF THE MAIN SERVICE PANEL DOES NOT HAVE VERIFIABLEGROUNDING ELECTRODE, IT IS THE CONTRACTORSRESPONSIBILITY TO INSTALL SUPPLEMENTAL GROUNDINGELECTRODE.12. EACH MODULE WILL BE GROUNDED USING THE SUPPLIEDCONNECTION POINTS IDENTIFIED ON THE MODULE ANDTHE MANUFACTURERS INSTALLATION INSTRUCTIONS.13. A LADDER SHALL BE IN PLACE FOR INSPECTION INCOMPLIANCE WITH OSHA REGULATIONS.14. PROPER ACCESS AND WORKING CLEARANCE WILL BEPROVIDED "WARNING: PV POWER SOURCE" TO BE PLACEDEVERY 10 FT.15. GFCI PROTECTION IN INVERTER. A L L W O R K T O C O M P L Y W I T H T H E F O L L O W I N G C O D E : N E C 2 0 1 7 C O D E I B C / I R C / I F C 2 0 1 8 C O D E 10/17/2022 MSP ACMTR CB RSI INV INV INV INV INV INV INV INV INV INV INV INV INV INV ELCELCMID SUB A E R I A L V I E W SITE PLAN, AERIAL VIEW N ISSUED FOR: PERMIT DATE 10/08/2022 www.bigdogenergy.com SOLAR PHOTOVOLTAIC SYSTEM DARIAN BESS DESIGNED BY CONTRACTOR INFORMATION P V - 2 80, K ST., REXBURG, ID 83440 BIG DOG RENEWABLE ENERGY CONTRACTOR LIC #: IDAHO #017916 620 PHEASANT RIDGE DR CHUBBUCK, ID 83202 208-242-3352 T 208-232-5935 F X__________________ R O O F D E S C R I P T I O N R O O F A R R A Y P I T C H A Z I M U T H # 1 2 4 ° 9 0 ° SITE PLANPANEL PLACEMENT MAY DIFFER FROMAPPROVED DESIGN DUE TO UNFORESEENOBSTRUCTIONS OR PERMITTING SETBACKSPROPOSED SYSTEMDC SIZE / AC SIZE:5.600 KW-DC / 4.060 KW-AC S O L A R P V M O D U L E I N V I N V E R T E R M S P M A I N S E R V I C E P A N E L M T R M E T E R C B C O M B I N E R B O X M I D I Q S Y S T E M C O N T R O L L E R 2 S U B S U B P A N E L E L C E N P H A S E I Q L O A D C O N T R O L L E R R S I R A P I D S H U T D O W N I N I T I A T O R A C A C D I S C O N N E C T TOTAL # OF PANELS:14 A B B R E V I A T I O N S S C A L E : N T S S C A L E : N T S K ST.ROOF TYPE:METAL 1 8 " C L E A R A N C E 1 8 " C L E A R A N C E 1 8 " C L E A R A N C E 1 8 " C L E A R A N C E 3 ' P A T H W A Y R O O F # 1 AC DISCONNECTWITHIN 3’ FROM UTILITY METERSERVICE UPGRADE TO 200A10/17/2022 ELECTRICAL SINGLE LINE DIAGRAM E L E C T R I C A L N O T E S SINGLE LINE DIAGRAM R A C K I N G & M O D U L E S A R E G R O U N D E D V I A A C O N T I N U O U S # 6 A W G C O P P E R C O N D U C T O R C O N N E C T E D W / W E E B S - M O D U L E S A R E F A C T O R Y P R O V I D E D W / 2 T H R E A D E D H O L E S T O F A C I L I T A T E L A N D I N G O F T H E L U G S A L L E Q U I P M E N T S H A L L B E P R O P E R L Y G R O U N D E D A N D B O N D E D I N A C C O R D A N C E W I T H A R T I C L E 2 5 0 . A L L C I R C U I T S C O N N E C T E D T O M O R E T H A N O N E S O U R C E S H A L L H A V E O V E R C U R R E N T D E V I C E S L O C A T E D S O A S T O P R O V I D E O V E R C U R R E N T P R O T E C T I O N F R O M A L L S O U R C E S 6 9 0 . 9 ( A ) ISSUED FOR: PERMIT DATE 10/08/2022 www.bigdogenergy.com SOLAR PHOTOVOLTAIC SYSTEM DARIAN BESS DESIGNED BY CONTRACTOR INFORMATION P V - 3 80, K ST., REXBURG, ID 83440 BIG DOG RENEWABLE ENERGY CONTRACTOR LIC #: IDAHO #017916 620 PHEASANT RIDGE DR CHUBBUCK, ID 83202 208-242-3352 T 208-232-5935 F X__________________ P R O P O S E D S Y S T E M D C S I Z E / A C S I Z E : 5 . 6 0 0 K W - D C / 4 . 0 6 0 K W - A C A L L M O D U L E S W I L L B E G R O U N D E D I N A C C O R D A N C E W I T H C O D E A N D T H E M A N U F A C T U R E R ' S I N S T A L L A T I O N I N S T R U C T I O N S . M O D U L E : U R E F B M 4 0 0 M F G - B B ( 4 0 0 W ) V o c = 3 7 . 2 0 V I s c = 1 3 . 6 8 A V m p = 3 1 . 1 7 V I m p = 1 2 . 8 4 A ELECTRICA L E Q U I P M E N T C A L L O U T S 5,600W TOTAL SOLAR ARRAY14 URE FBM400MFG-BB (400W) PANELSWIRE AND CONDUIT CALLOUTSSOLADECK M O D E L 0 7 8 3 - 4 1 J U N C T I O N BOX/ROOF P E N E T R A T I O N , 6 0 0 V (2) #12 AWG THWN-2(1) #12 AWG THWN-2 GND IN 3/4" EMT OUTSIDE ABC23ENPHASE I Q C O M B I N E R 4 / 4 C 240VAC, N E M A 3 R , U L L I S T E D , (W/ 80A OF D I S T R I B U T E D G E N E R A T I O N BREAKERS ) , 1 2 5 A B U S B A R R A T I N G 290.0W EN P H A S E I Q 8 P L U S - 7 2 - 2 - U S MICROINVE R T E R ( 2 9 0 V ) O N E P E R P A N E L 240VAC, 1. 2 1 A , I P 6 7 , U L L I S T E D , WITH PLC C O M M U N I C A T I O N 12/2 ROMEX INSIDE(3) #10 AWG THWN-2(1) #10 AWG THWN-2 GND IN 3/4" EMT4DENPHASE I Q C O M M U N I C A T I O N S G A T E W A Y WITH INTE G R A T E D R E V E N U E G R A D E P V PRODUCTI O N M E T E R 5(2) #14 AWG THWN-2(1) #14 AWG THWN-2 GND IN 3/4" EMT 2 BRANCHES OF 7 INVERTERS CONNECTED IN SERIES (10) #10 A W G T H W N - 2 (2) #10 AW G T H W N - 2 G N D I N 3 / 4 " E M T 78(2) #14 AW G T H W N - 2 J U N C T I O N B O X , 6 X 6 X 4 , N E M A 3 R U L L I S T E D G 2 0 0 A E N P H A S E I Q C O N T R O L L E R 2 ( E P 2 0 0 G 1 0 1 - M 2 4 0 U S 0 1 ) H R A P I D S H U T D O W N I N T I T I A T O R I J K 1 2 5 A S U B P A N E L F O R E S S E N T I A L L O A D S W / N O L O A D S O V E R 2 0 A ( W / 1 0 0 A M A I N B R E A K E R ) E N P H A S E I Q L O A D C O N T R O L L E R , N E M A 3 R , C O N T R O L U P T O 2 X 3 6 A R E S I S T I V E O R 3 H P / 2 5 A I N D U C T I V E L O A D F E 2 0 0 A ( N ) M A I N S E R V I C E P A N E L , 1 Ø , 2 4 0 V ( W / ( N ) 2 0 0 A M A I N B R E A K E R T O P F E D ) L S Q U A R E D S A F E T Y S W I T C H , # D 2 2 1 N R B 2 5 0 V A C , 3 0 A , N E M A 3 R , F U S E D , U L , N E M A , C S A , N O M C E R T I F I E D W / 3 0 A F U S E S 1 E L E C T R I C A L L I N E D I A G R A M P V - 3 S C A L E : N T S 1 E L E C T R I C A L L I N E D I A G R A M P V - 3 S C A L E : N T S 1 E L E C T R I C A L L I N E D I A G R A M P V - 3 S C A L E : N T S O N E P E R P A N E L 7 M O D U L E S I N S E R I E S B A 1 2 B R A N C H 2 2 0 A N G 2 0 A 1 5 A D C 4 6IG5N100APAGE 143 FORCOMPLIANCE WITHNEC 690.12 H100AENG(N)200A FLOAD1/2P 100ALOAD2/2PLOAD3/2PLOAD4/2P 6KLARGEST LOAD IS20A 30A L O A D 2 JJ79 9 L O A D 1 L O A D 3 9 9 L O A D 4 L 1 L 2 N G LL1L2NG48 G 3 G 3 AC DISCONNECTWITHIN 3’ FROM UTILITY M E T E R 2 0 0 A B I - D I R E C T I O N A L U T I L I T Y M E T E R , 1 Ø , 2 4 0 V 1ENPHASE TRUCK LINE(1) #6 AWG THWN-2 GND 1 . P V A R R A Y S A R E P E R S I N G L E L I N E . 2 . P V A R R A Y W I R I N G T O J U N C T I O N I S # 1 0 A W G U S E 2 W / F I E L D I N S T A L L E D M C C O N N E C T O R S T O I N T E R F A C E W / M O D U L E S . 3 . P V A R R A Y C O M B I N E R / J U N C T I O N B O X P R O V I D E S T R A N S I T I O N F R O M A R R A Y W I R I N G T O C O N D U I T W I R I N G . 4 . U S E U F E R G R O U N D E L E C T R O D E S Y S T E M F R O M I N V E R T E R T O E X I S T I N G M A I N S E R V I C E G R O U N D E L E C T R O D E P E R N . E . C . 2 5 0 . 5 8 . 5 . G R O U N D E L E C T R O D E C O N D U C T O R F R O M I N V E R T E R T O G R O U N D E L E C T R O D E T O B E M I N I M U M P R O T E C T I O N O F B A R E A R M O R S H E A T H E D C A B L E F O R A L L C O N D U C T O R S I Z E S . 6 . A L L G R O U N D C O N N E C T E D T O M A I N S E R V I C E G R O U N D I N M A I N S E R V I C E P A N E L . 7 . C O N N E C T O R S S H A L L B E P O L A R I S O R E U R O S T R I P I T C O N N E C T O R S . 8 . I N V E R T E R S H A L L B E P E R S I N G L E L I N E , S E E A T T A C H E D C U T S H E E T . 9 . I N V E R T E R I S P E R S I N G L E L I N E . 1 0 . A C D I S C O N N E C T S H A L L B E P E R S I N G L E L I N E . 1 1 . E Q U I P M E N T G R O U N D I N G C O N D U C T O R S O N A C A N D D C S I D E S I Z E D A C C O R D I N G T O N . E . C . 6 9 0 . 1 2 . P O L E O F P V A R R A Y R E F E R E N C E D T O G R O U N D A T T H E I N V E R T E R I N S I N G L E L I N E . 1 3 . A L L C O N D U C T O R S S H A L L B E 6 0 0 V , 9 0 C S T A N D A R D C O P P E R . A L L C O N D U C T O R S I N C O N D U I T S H A L L B E T H W N - 2 . 1 4 . M A X I M U M D C V O L T A G E D R O P S H A L L B E 2 . 5 % 1 5 . A L L C O N D U C T O R S S H A L L B E I N C O N D U I T U N L E S S O T H E R W I S E N O T E D . 1 6 . A L L W O R K T O C O M P L Y W I T H N E C 2 0 1 7 C O D E . 1 7 . D C A R R A Y C O N D U C T O R S A R E T O R E M A I N O U T S I D E O F B U I L D I N G P R I O R T O F U S I B L E C O M B I N E R B O X O R F U S I B L E D C D I S C O N N E C T M E A N S . 1 8 . E X A C T C O N D U I T R U N L O C A T I O N S S U B J E C T T O C H A N G E . 1 9 . 3 . 0 P S F M A X ( . 5 P S F F R O M R A C K I N G , 2 . 5 P S F F R O M M O D U L E S ) D E A D L O A D C O N T R I B U T E D F R O M S O L A R A R R A Y . 2 0 . A R C F A U L T I N S T A L L E D A T I N V E R T E R O R I N C O M B I N E R B O X . 2 1 . D C G R O U N D F A U L T P R O T E C T I O N I N T E G R A T E D I N I N V E R T E R . 2 2 . P O I N T O F C O N N E C T I O N B R E A K E R T O B E L O C A T E D O P P O S I T E E N D O F B U S B A R F R O M M A I N U N L E S S O T H E R W I S E N O T E D . 2 3 . A N Y U N D E R G R O U N D W I R I N G M E T H O D S W I L L C O M P L Y W I T H N E C 3 0 0 . 5 ( J ) , 3 0 0 . 7 ( B ) , 3 5 2 . 4 4 , A N D O T H E R S E C T I O N S O F C H A P T E R 3 A S A P P L I C A B L E . 2 4 . A N Y E X P O S E D P V C C O N D U I T S H A L L C O M P L Y W I T H N E C 3 5 2 . 1 0 2 5 . A L L P V S Y S T E M D C C I R C U I T S R U N I N S I D E A B U I L D I N G S H A L L B E C O N T A I N E D I N A M E T A L R A C E W A Y I N A C C O R D A N C E T O N E C 6 9 0 . 3 1 ( G ) 2 6 . C O M P L I E S W I T H 7 0 5 . 1 2 ( B ) ( 2 ) ( 3 ) ( B ) 2 7 . S U P P L Y S I D E C O N N E C T I O N W I T H L I S T E D I N S U L A T I O N P I E R C I N G C O N N E C T O R S I N A C C O R D A N C E W I T H 7 0 5 . 1 2 ( A ) A N D 2 3 0 . 8 2 2 8 . C O N N E C T I O N A T P A N E L S E C O N D A R Y S E R V I C E L O C A T I O N 2 9 . C O M P L I E S W I T H 7 0 5 . 1 2 ( B ) ( 2 ) ( 1 ) ( B ) O N E P E R P A N E L 7 M O D U L E S I N S E R I E S B A 1 2 B R A N C H 1 6(3) #3 AWG THWN-2(1) #8 AWG THWN-2 GND IN 1-1/4" EMT (3) #8 AWG T H W N - 2 (1) #12 AW G T H W N - 2 G N D I N 3 / 4 " E M T 9SERVICE UPGRADETO 200A REQUIRED SIGNAGE ISSUED FOR: PERMIT DATE 10/08/2022 www.bigdogenergy.com SOLAR PHOTOVOLTAIC SYSTEM DARIAN BESS DESIGNED BY CONTRACTOR INFORMATION P V - 4 80, K ST., REXBURG, ID 83440 BIG DOG RENEWABLE ENERGY CONTRACTOR LIC #: IDAHO #017916 620 PHEASANT RIDGE DR CHUBBUCK, ID 83202 208-242-3352 T 208-232-5935 F X__________________ REQUIRED SIGNAGE 2. LABEL FOR SOLAR AC DISCONNECT: S Y S T E M A C V O L T A G E : 2 4 0 V T O T A L R A T E D A C A M P S : 3 0 A S Y S T E M A C V O L T A G E : 2 4 0 V 3. THE FOLLOWING SIGNAGE MUST HAVE A MINIMUM OF 3/8"HIGH LETTERING, IN ARIAL FONT (NON-BOLD), WITH CAPITALLETTERS, WHITE ON RED BACKGROUND AND A REFLECTIVE,WEATHER RESISTANT MATERIAL.1. PROVIDE A PLACARD WITH THE FOLLOWING WORKING IN 1/4"HIGH LETTERING PER NEC 690-17.AT THE MAIN SERVICE DISCONNECT PROVIDE A SIGN WITH THEFOLLOWING WORDING: FOLLOWING WORDING:THE SIGN SHOULD BE PLACED ON THE OUTSIDE COVER IF THE MAINSERVICE DISCONNECT IS OPERABLE WITH THE SERVICE PANEL CLOSED.CUSTOMER OWNEDON SITE POWER GENERATIONSYSTEM DISCONNECT D I R E C T C U R R E N T P H O T O V O L T A I C S O U R C E S Y S T E M A C V O L T A G E : 2 4 0 V M A X A C C I R C U I T C U R R E N T : 1 . 2 1 A 8. T H E F O L L O W I N G S I G N M U S T B E P R O V I D E D O N T H E O U T S I D E ( O R W I T H I N 3 ' O F ) T H E S E R V I C E P A N E L B O A R D , A S R E Q U I R E D P E R N E C 6 9 0 . 5 6 ( C ) ( 1 ) : R A P I D S H U T D O W N S W I T C H F O R S O L A R P V S Y S T E M P H O T O V O L T A I C S Y S T E M E Q U I P P E D W I T H R A P I D S H U T D O W N A L L S I G N A G E M U S T B E P E R M A N E N T L Y A T T A C H E D A N D B E W E A T H E R R E S I S T A N T / S U N L I G H T R E S I S T A N T A N D C A N N O T B E H A N D - W R I T T E N . N E C 1 1 0 . 2 1 ( B ) FIRE DEPARTMENT REQUIRED SIGNAGE4. LABELS TO BE INSTALLED ON FACE OF THE UTILITY AC DISCONNECT:5. LABEL INSTALLATION AT INTERCONNECT BREAKER:10 . S I G N A G E R E Q U I R E D A T M I C R O I N V E R T E R P E R N E C 6 9 0 . 5 3 : 9. S I G N A G E R E Q U I R E D A T S E R V I C E P A N E L B O A R D P E R N E C 6 9 0 . 5 4 : 7. A T P V D I S C O N N E C T S W I T C H A S R E Q U I R E D P E R N E C 6 9 0 . 5 6 ( C ) ( 3 ) : 6. R E F L E C T I V E P L A C A R D A T S E R V I C E S T A T I N G : "SOLAR AC DISCONNECT"WARNING:ELECTRICAL SHOCK HAZARD.DO NOT TOUCH TERMINALS. TERMINALSON BOTH THE LINE AND LOAD SIDES MAYBE ENERGIZED IN THE OPEN POSITION.WARNING:INVERTER CONNECTION.DO NOT RELOCATE THISOVERCURRENT DEVICE. 1 1 . A T E V E R Y E N C L O S U R E , E V E R Y 1 0 ’ A L O N G C O N D U I T O R M C C A B L E , A N A T E A C H S I D E O F W H E R E T H E C O N D U I T O R C A B L E P A S S E S T H R O U G H A W A L L , F L O O R , O R A N Y O T H E R P A R T I T I O N . W A R N I N G : P O W E R S O U R C E T H E M A R K I N G S S H A L L B E P E R M A N E N T L Y A F F I X E D A N D V I S I B L E A F T E R I N S T A L L A T I O N P E R N E C 6 9 0 . 3 1 ( G ) ( 3 - 4 ) . WARNINGDUAL POWER SUPPLYSOURCES: UTILITY GRID ANDPV SOLAR ELECTRIC SYSTEM