Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
FA SUBMITTAL - 22-00166 - BYUI Benson - Room #190 Remodel
FIRE CONTROL INSTRUMENTS-GAMEWELL-BOSCH 1481 SOUTH MAJOR STREET S.L.C., UT 84115 P. 801-468-8300 F. 801-468-8305 BYU-I Benson Remodel 525 South Center Street Rexburg, ID. 83480 Benson Building Remodel BYU-Idaho Fire Alarm System Submittal & Drawings PROJECT Equipment Manufacturer: Gamewell-FCI Benson Building Authorized Distributor: Nelson Fire Systems Remodel 1481 S Major St BYU-Idaho SLC, UT 84115 Fire Alarm System 801-468-8300... BYU-I Benson Building 525 South Center Street Rexburg, ID. 83480 TABLE OF CONTENTS Data Sheet Part No. Description Gamewell-FCI E3 Series Emergency Evacuation System (Existing) Gamewell-FCI PC2WL White Horn/Strobe – Ceiling Mount Gamewell-FCI HPFF8 NAC Power Supply w/Sync Module Battery Calculations HPFF8 Battery Calc CKT Voltage Drops Drawings Sheet No. Description Cover Page FA-C-01 Fire Alarm Cover Riser Diagram FA-R-01 Fire Alarm Riser and Matrix Level 1 FA-1-01 Notification Circuit E3 SERIES® BROADBAND SYSTEM Intelligent, Networked, Multi-Channel Fire Alarm Control E3 Series Broadband System GENERAL The Gamewell-FCI, E3 Series® Broadband System is a modular design and offers a wide range of configurations from two basic sub- assemblies. These sub-assemblies form an integrated, distributed fire alarm system that includes audio evacuation and fire command capability. The network communication transmits all fire alarm, audio evacuation, voice paging, and fire fighter communications. This System can be used as a component of the following E3 Series Systems: • E3 Series Broadband Voice Evacuation System • E3 Series Combined Fire and Mass Notification System The E3 Series Broadband System is a revolutionary advance in fire detection and emergency voice evacuation system design. E3 Series Broadband employs proven technology and expands it to accomplish emergency multi-channel voice evacuation, two-way fire fighter communications, and building control applications, while simultaneously sent over a single pair of wires or fiber-optic cable. It is a true peer-to-peer, token ring passing, networked system capable of supporting up to 64 individual nodes. In addition, the Addressable Node Expander (ANX) board expands the network to 122 nodes. All system status, control-by-event sequences, audio voice paging, and fire fighter telephone signals are sent between nodes over a single pair of wires or fiber-optic cable. Each E3 Series Broadband node can be spaced along the network a maximum distance of 3,000 feet (914.4 m) over an unshielded, twisted-pair of wires or fiber-optic cable with signal loss up to 8dB loss. Built-in isolation at each node permits Class B, Class A and Class X network configurations. The E3 Series Broadband is simple to configure for any project requirement. A complete E3 Series Broadband application can be assembled from the following types of nodes: • ILI-E3/ILI95-E3 Series • ANX • INCC Command Center •INX Transponder FEATURES AND BENEFITS • IBC Seismic Certified • Listed under UL® Standard 864, 10th Edition • Listed under UL Standard UL2572, 2nd Edition for Mass Notification • UL Listed for smoke control (dedicated and non-dedicated) when properly configured. • FM/UL Listed for Pre-action/Deluge use • All communication signals and control-by- event sequences over a single pair of twisted, unshielded wires or fiber-optic cable • Distributed architecture, including Class X wiring configurations, allow system components to continue normal operation with no loss of function during single line fault conditions • Integrates INX transponders and INCC command centers to create a complete audio evacuation system with up to 122 nodes • Redundant command centers with microphone and fire fighter’s handset are easily configured by adding INCCs • Uses state-of-the-art digital signal processor (DSP) technology for efficient audio compression and filtering • Provides up to 150 watts of audio power from 3 AM-50 Series amplifiers with an additional 50 watts of standby power in each Intelligent Network Transponder (INX) The E3 Series® Broadband System offers audio evacuation and fire command configurations. Page 2 of 6 — 9020-0613:O General The E3 Series Broadband System is capable of the most sophisticated sequences of operations. The Field Configuration Program (FCP) is based on Boolean logic statements providing AND, OR, NOT, and XOR logic operators. These operators can be combined to produce additional Boolean operators such as NAND, NOR, XNOR. The E3 Series Broadband is software-programmable for multi-channel digital audio applications. It is ideal for use with a wide range of complex system applications including high-rise or campus installations. An array of cabinets allows for neat, compact, installations. A comprehensive set of timing functions can be attached to any input/ output logic statement for the staggered reset of fan control relays, time-delayed alarm activation, automatic. The E3 Series control panel is a microprocessor-based fire alarm control panel that uses the following: • ILI-E3/ILI95-E3 Series, Intelligent Loop Module or • ANX with two signaling line circuits • Two notification appliance circuits When the E3 Series control panel transmits to remote locations, the optional RPT-E3 provides the ILI-E3/ILI95-E3 Series or the ANX with signal boosting and transient protection, as well as connectivity for both wire and fiber-optic cables. Other options also include an integral Digital Alarm Communicator Transmitter (DACT) that supports most popular reporting formats. INCC (Intelligent Network Command Center) The Intelligent Network Command Center (INCC) serves as the central point of interface between an operator and the system’s audio evacuation, fire fighter intercom, and building network. The INCC occupies a single address on the E3 Series Broadband network. A typical INCC assembly consists of the following: • Intelligent Network Interface-Voice Gateway (INI-VGC-Third Generation) or (INI-VGC-UTP-fiber-optic or unshielded twisted-pair) modules • One or more Addressable Switch Modules (ASM-16) • Optional Network Graphic Annunciator (NGA) • Remote 48 LED driver module (ANU-48) Other component options include a paging microphone and a fire fighter’s handset that connects to the INI-VGC (Third Generation) or INI-VGC-UTP module. Each INI-VGC (Third Generation) or INI-VGC- UTP module can support up to 16 ASM-16 modules. Each ASM-16 has 16 push-button switches for a maximum capac- ity of 256 switches per INI-VGC command center. Each switch has three associated LEDs, colored green, yellow, and red. These switches and their LEDs that are fully programmable to serve any system function desired. These switches and LEDs can control the following: • audio speaker circuits • addressable relay outputs • notification appliance circuits • fire fighter phone control circuits • any other special application that might be required Multiple INCCs can be configured into the E3 Series Broadband network to serve as a completely independent command center to operate either for the local area or to operate as remote command centers mimicking, in part or in whole, the function of a main com- mand center. INX (Intelligent Network Transponder) The Intelligent Network Transponder (INX) acts as a network audio transponder for the E3 Series Broadband Network. The INX transponder serves as the point of distribution for the sys- tem’s audio and fire fighter telephone circuits and occupies a single node on the E3 Series Broadband network. A typical INX assembly consists of the following components: The INX transponder occupies a single address on the network and provides termination points for the network connection using either a pair of unshielded twisted-pair wire or fiber-optic cable. The INX transponder receives its power from a PM-9/PM-9G, 9 ampere, filtered, switching power supply providing 24 VDC nominal operating voltage. The PM-9/PM-9G has an integral standby battery charger capable of recharging up to 55 A/H batteries. The E3BB-BB-BC/INX cabinet can house up to 18 A/H sized batteries. INI-VGX (Intelligent Network Interface-Voice Gateway) The INI-VGX uses advanced Digital Signal Processing (DSP) technology for audio compression and filtering allowing the E3 Series Broadband to produce a superior audio tone while conserving network bandwidth to broadcast an instantaneous response. Background noise is automatically filtered during voice paging and fire fighter communications increasing audibility and eliminating the need for push-to-talk devices. The INI-VGX can accommodate up to 16 different messages with a total combined duration of three minutes. Each message can be field installed via a laptop computer and setup to broadcast a voice message or an evacuation tone. The INI-VGX also provides a fire fighter phone riser and an addressable signaling line circuit that can connect to multiple phone jacks or warden stations through as many as 16 AOM-TELF modules. In addition, the INI-VGX SLC can support up to 32 speaker circuits using the AOM-2SF for single channel applications. AM-50 Series Amplifiers The INX or INX CAB-B cabinet can contain up to four AM-50 Series amplifiers that produce 50 watts of power @ either 25 VRMS or 70.7 VRMS audio output. Each amplifier includes two separate speaker circuits that can be wired Class B or Class A. In addition, each amplifier can produce its own tone or message independently of other system amplifiers. Thus, an INX transponder can produce three audio channels simultaneously. Each INX transponder can support up to four AM-50 Series amplifiers operating as main amplifiers with one AM-50 Series amplifier used as a fail-safe backup amplifier. • ANX • ILI-MB-E3/ILI95-MB-E3 • INI-VGX Module • ILI-S-E3/ILI95-S-E3 • PM-9/PM-9G power supply • Up to four AM-50 Series amplifiers 9020-0613:O Page 3 of 6 Figure 1 illustrates the INCC Command Center and the INX Cabinet. Figure 1 INCC Command Center and INX FIRE FIRE IN X E3 Series with 2 notification appliance circuits, each rated 2.0 amps. @ 24 VDC (Class 2 Power-Limited). Two analog addressable signaling line circuits (Class 2 Power-Limited) (Class “A”) INCC-C Command Center with optional Microphone and Firefighter’s Handset ASM-16 Addressable Switch Modules with 16 programmable, addressable switches, each with 3 programmable indicating LEDs: (red, green yellow) INX Transponder with 6 independently programmable speaker circuits, each rated 50 watts (Class 2 Power-Limited) Three simultaneous Audio channels up to 16 programmable voice messages Optional Digital Alarm Communicator Transmitter (DACT-E3) for local or network- wide event reporting One signaling line circuit with 16-AOM-TELF and 32 AOM-2SF addressable devices (AOM-TELFs shown) (Class “B”) standard (Class 2 Power-Limited) Firefighter phone riser (Class 2 Power-Limited) FIRE FIRE Note: The maximum loss between nodes is 8dB using fiber-optic cable. For Class A only, twisted-pair or fiber- optic cable, the maximum distance between nodes is 4,500 ft. (1372m). Class 2 Power-Limited Page 4 of 6 — 9020-0613:O Figure 2 E3 Series Broadband System Initiating / Control Devices NAC NAC FIRE FIRE One phone riser One SLC (16 AOM-TELFs & 32 AOM-2SFs) 6 Speaker appliance circuits 150 watts max. @ w/ 50 watts standby One phone riser NAC NAC FIRE FIRE Local Annunciators, LCD-E3 (max. 6) and LCD-7100, (max. 5) Global display for all network events if set to Region “0” Initiating / Control Devices One SLC (16 AOM-TELFs & 32 AOM-2SFs) One phone riser One SLC (16 AOM-TELFs & 32 AOM-2SFs) Optional Integral DACT Initiating / Control Devices Local annunciators, LCD-7100, (max. 5) Global display for all network Events add LCD-E3 (m ax. 6) FIRE Connect if wired Class A or Class X IN X IN X IN X 6 Speaker appliance circuits 150 watts max. @ w/ 50 watts standby 6 Speaker appliance circuits 150 watts max. @ w/ 50 watts standby E3 Series E3 Series E3 Series Note: The maximum loss between nodes is 8dB using fiber-optic cable. For Class A only (twisted-pair or fiber-optic cable), the maximum distance between nodes is 4,500 ft. (1372m). 9020-0613:O Page 5 of 6 Ordering Information Part Number Description E3 Series Control ILI95-MB-E3 Intelligent Loop Interface95-Main Board ILI-MB-E3 Intelligent Loop Interface-Main Board ILI-S-E3 Intelligent Loop Interface-Expansion ILI95-S-E3 Intelligent Loop Interface95-Expansion ANX-SR Addressable Node Expander-Single Ring ANX-MR-FO Addressable Node Expander-Multi-Ring Twisted-Pair ANX-MR-UTP Addressable Node Expander-Multi-Ring Fiber-Optic LCD-E3 LCD Keypad Display PM-9/PM-9G Power Supply RPT-E3-UTP Network Repeater DACT-E3 Digital Alarm Communicator Transmitter LCD-7100 (Optional) Remote Serial LCD Display INCC Intelligent Network Command Center 1100-0455 ASM-16 Programmable Switch Module (occupies single slot of the inner door) ANU-48 Remote LED Driver INCC-ID Inner door w/6 single slots INCC-CABR INCC backbox (black) with red outer door, Dimensions: 19” W x 19” H x 4” D (48 W x 48 H x 10 cm) 1100-0505 NGA Network Graphic Annunciator INI-VG Series (Third Generation-Voice Gateway Models): INI-VGC Command Center Voice Gateway with unshielded twisted-pair wire networking, optional fiber-optic module connection FML-E3 Fiber-Optic module, multi-mode fiber connec- tor, single channel FSL-E3 Fiber-optic module, single-mode fiber con- nector, single channel INI-VG Series (Legacy Modules): 1100-1321 INI-VGC-FO: Command Center Voice Gateway for fiber-optic only 1100-1322 INI-VGC-UTP: Command Center Voice Gate- way for unshielded twisted-pair wire only Ordering Information Part Number Description Optional Accessories 1100-0503 ANU-48, Remote LED Driver 1100-0451 INICC-TEL, Fire Fighter Telephone Handset 1100-0452 INCC-MIC, Paging Microphone Module (occupies one single slot of Inner Door) 1100-0450 Command Center Blank Plate, 3-Pack INX Intelligent Network Transponder INI-VG Series (Third Generation-Voice Gateway Models): INI-VGX Voice Transponder Gateway with unshielded twisted-pair wire networking, optional fiber-optic module connection FML-E3 Fiber-Optic module, multi-mode fiber connector, single channel FSL-E3 Fiber-optic module, single-mode fiber connector, single channel INI-VG Series (Legacy Modules): 1100-1323 INI-VGX-FO, Transponder Voice Gateway, fiber-optic only 1100-1324 INI-VGX-UTP, Transponder Voice Gateway, unshielded twisted-pair wire only Power Supply: PM-9/PM-9G INX 9 ampere Power Supply AM-50 Series Amplifiers: 1100-0456 AM-50-25, INX 50 Watt Amplifiers 25 VRMS only AM-50-70 INX 50 Watt amplifier 70.7 VRMS output Cabinets: INX-CAB INX Backbox with Black Door Dimensions: 19” W x 19” H x 4” D (48 x 48 x 10 cm) INX-CABR INX Backbox with Red Door Dimensions: 19” W x 19” H x 4” D (48 x 48 x 10 cm) INX CAB-B Enclosure louvered door and INX-CAB-B mounting plate Dimensions: 19 3/8” W x 19 3/8” H x 4.5” D (49 W x 39 H x 11 D cm) For additional information on the cabinets, refer to the E3 Series Cabinets Data Sheet (Part Number: 9020-0649). Seismic Battery Bracket Kits For information on the types of Seismic Battery Bracket Kits available and the Seismic Battery Bracket Kit Part Numbers, refer to the following documents: Seismic Battery Bracket Installation Guide, P/N: 53839 E3 Series Cabinets Data Sheet P/N: 9020-0649 E3 SERIES® BROADBAND SYSTEM TECHNICAL SPECIFICATIONS 9020-0613 | O | 06/20 ©2020 Honeywell International Inc. Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.gamewell-fci.com E3 Series® and Gamewell-FCI® are registered trademarks of Honeywell International Inc. UL® is a registered trademark of Underwriter’s Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Country of origin: U.S.A. SYSTEM Detailed product specifications may be found in the following documents: 9020-0542: INCC Intelligent Network Command Center Data Sheet 9020-0637: E3 Series Control Panel Data Sheet 9020-0541: INX Intelligent Network Transponder Data Sheet 9021-60758: E3 Series Combined Fire and Mass Notification Data Sheet TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 – 49°C/32 – 120°F and at a relative humidity 93% ± 2% RH (non- condensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 – 27°C/60 – 80°F. STANDARDS The E3 Series Broadband System is designed to comply with the following standards: UL Standards: UL 864, 10th Edition UL 2572, 2nd Edition for Mass Notification AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult the factory for the latest listing status. UL Listed: S1869, UL 864, 10th Edition UL 2572, 2nd Edition for Mass Notification FM Approved: 3025415 MEA FDNY: 6175 231-06-2E CSFM: 7165-1703:125 City of Chicago Approved: 7165-1703:125 City of Denver Approved ISO 9001 Certification Ceiling Horn Strobe L-Series, Indoor Strobes and Horn Strobes Indoor Selectable-Output Strobes/Horn Strobes for Ceiling Applications Notification Appliances General The L-Series audible visible notification products offer the most versatile and easy-to- use product line of horns, strobes, and horn strobes in the industry. This product includes lower current draws and a modern aesthetic design which reduce installation times and maximize profits. In addition, the L-Series offers white and red plastic housings and wall and ceiling mounting options. Similar to the entire L-Series product line, the ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying the installation. All devices offer a plug-in design so that there is minimal intrusion into the backbox. These features make installations fast and foolproof while eliminating costly and time-consuming ground faults. To simplify the installation, the L-Series uses a universal mounting plate allowing you to mount the devices to a wide array of backboxes. With an on-board shorting spring, Installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to suit a wide range of application requirements using the following: • Field-selectable candela settings • Automatic selection of 12- or 24-volt operation • Rotary switch for horn tones with two volume selections FEATURES & BENEFITS • Listed for ceiling mounting only •Features a plug-in design so that there is minimal intrusion into the backbox •Designed with a tamper-resistant construction • Provides an automatic selection of 12- or 24- volt operation at 15 and 30 candela • Uses field-selectable candela settings on the following ceiling units: - 15 - 30 - 75 - 95 - 115 - 150 - 177 • Produces horn rated at 88+ dBA at 16 volts • Offers a rotary switch for horn tone and two volume selections • Includes a universal mounting plate for ceiling units • Contains a mounting plate with a shorting spring feature that checks the wiring continuity before device installation • Compatible with MDL3 sync module • Supports electrical compatibility with the legacy SpectrAlert and the SpectrAlert Advance devices 2 Architect/Engineer Specifications General The L-Series ceiling-mount strobes and horn strobes shall mount to any of the following: • double-gang backbox • 4-inch octagon backbox • a standard 4 x 4 x 1 1/2-inch backbox Two-wire products shall also mount to a single-gang compact 2 x 4 x 17/8-inch backbox. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, the L-Series products, when used with the Sync•Circuit Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When it is used with the Sync•Circuit Module, the following occur: • 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts. • 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. The Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have the following field- selectable candela settings including: Strobe The strobe shall be an L-Series Model _______ listed to UL Standard 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/ reflector system. Horn Strobe Combination The horn strobe shall be an L-Series Model _______ listed to UL Standard 1971 and UL Standard 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate o a coded or non-coded power supply. Synchronization Module The module shall be a Sync•Circuit model MDL3 listed to UL Standard 464 and shall be approved for fire protective service. The module shall synchronize the L-Series strobes at 1 Hz and synchronize horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single-pair of wires. The module shall mount to a 4 11/6 x 4 11/16 x 2 1/8-inch backbox. The module shall also control two Style Y (Class B) circuits or one Style Z (Class A) circuit. The module shall synchronize multiple zones. Daisy-chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. UL Current Draw Table 1 lists the UL maximum strobe current draw. •15 •30 •75 •95 • 115 • 150 • 177 Candela 8-17.5 Volts 16-33 Volts FWRDC DC 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 Table 1: UL Maximum Strobe Current Draw (mA RMS) 3 UL Current Draw Data Table 2 lists the maximum UL Current Draw (mA RMS) allowed for 2-Wire Horn Strobes. Horn Strobe Tones and Sound Output Data Table 3 lists the horn strobe tones and sound output date. DC Input 8-17.5 Volts 16-33 Volts 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temporal Low 95 166 54 71 124 161 170 216 258 3.1K Temp Hi 111 164 69 94 147 163 184 229 257 3.1K Temp Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temporal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 256 289 3.1K Temporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 Table 2 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe Switch Position Sound Pattern dB 8–17.5 Volts 16–33 Volts FWR DC DC 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 Table 3: Horn Strobe Tones and Sound Output Data 4 L-Series Ordering Information Ceiling Horn Strobes: PC2RL: 2-Wire, Horn Strobe, Red PC2WL: 2-Wire, Horn Strobe, White PC4RL: 4-Wire Ceiling Horn Strobe, Red, FIRE PC4WL: 4Wire Ceiling Horn Strobe, White, FIRE Ceiling Strobes: SCRL: Strobe, Red SCWL: Strobe, White SCWL-CLR-ALERT: Strobe, White, ALERT L-Series Ordering Information Accessories: TRC-2: Universal Ceiling Trim Ring Red TRC-2W: Universal Ceiling Trim Ring White SBBCRL: Ceiling Surface Mount Back Box, Red SBBCWL: Ceiling Surface Mount Back Box, White L-Series Dimensions Figure 1 illustrates the dimensions for the ceiling-mount horn strobes. Figure 1 Ceiling-Mount Horn Strobes L-Series Dimensions Figure 2 illustrates the dimensions for the ceiling backbox surface mount backbox. Figure 2 Ceiling-Surface-Mount Backbox 2.47" (62.7 mm) 1.37" (34.8 mm)6.83" diameter (173 mm) 6.92" diameter (175.77 mm) 2.50" (64 mm) L- Series Dimensions Figure 3 illustrates the dimensions for the ceiling backbox surface mount backbox. Figure 3 2-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Backbox SL Series Dimensions Figure 4 illustrates the dimensions for the ceiling backbox surface mount backbox. Figure 4 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Backbox L-Series, Indoor Strobes and Horn Strobes Technical Specifications 9021-60928 | C | 03/18 ©2018 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit: http://www.gamewell- fci.com/en-US/ documentation/Pages/ Listings.aspx E3 Series® and Gamewell-FCI® are registered trademarks of Honeywell International Inc. UL® is a registered trademark of Underwriter’s Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com For more information Learn more about Gamewell-FCI’s L-Series, Indoor Strobes and Horn Strobes and other products available by visiting www.Gamewell-FCI.com SYSTEMS Temperature Ranges: Standard Operating Temperature: 32°F to 120°F (0°C to 49°C) Humidity Range: 10 to 93% non-condensing Voltages: Strobe Flash Rate: 1 flash per second Nominal Voltage: Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range2: 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3): 8.5 to 17.5V(12 V nominal) or 16.5 to 33 V(24V nominal) Wire Gage: Input Terminal Wire Gauge: 12 to 18 AWG Dimensions: Ceiling-Mount Dimensions (including lens): 6.8" diameter × 2.5" high (173 mm diameter × 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions (SBBCR, SBBCW): 6.9" diameter x 3.4" high (175 mm diameter x 86 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non- regulated, time-varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 – 49°C/32 – 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 – 27°C/60 – 80°F. STANDARDS The L-Series, Ceiling Strobes and Horn Strobes are designed to comply with the following standard: UL Standard: UL 1971 and UL 464 AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S5512, S4011 CSFM: 7135-1653:0503 7125-1653:0504 ISO 9001 Certification GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2010 by Honeywell International Inc. All rights reserved.www.gamewell-fci.com 9021-60521 Rev. B page 1 of 2 HPFF8 NAC Expander/Power SupplyDescription The Gamewell-FCI, HPFF8 is a Notification Appliance Cir- cuit (NAC) expansion panel designed to extend the power capabilities of existing NACs and provide power for the auxiliary devices. The HPFF8 connects to any 12 or 24V Fire Alarm Control Panel (FACP) or stand alone. The HPFF8 is available in 8.0 amps. It provides regulated and filtered 24VDC power to each of the four NACs and an auxiliary output. The NAC outputs are rated at 3.0 amps each (the total output cannot exceed 8.0 amps). The auxil- iary output is rated at 2.0 amps. This output is continuously supplied, even in alarm, and therefore must be taken into account for power supply loading and battery size calcula- tions. The NAC outputs may be configured as any of the follow- ing: • Four Class B (Style Y) • Two Class A (Style Z) • Two Class B and one Class A • Four Class A with the optional HPP31076 Class A adapter installed These power supplies contain an internal Battery charger capable of charging up to 26.0 amp-hour (AH) batteries. The HPFF8 is mounted in lockable wall cabinet units that can accommodate up to two (2), 18AH batteries. A multi- pack option allows for up to four chassis mount units installed in a single lockable SBB-D4 enclosure. These chassis mount units have a "CM" suffix, HPFF8CM and can accommodate two 12AH batteries. Power supplies are available in either 120VAC/60 Hz or 240VAC/50 Hz. One of the most challenging aspects of a retrofit applica- tion is locating the existing End-of-Line (EOL) resistor. In these applications that have EOL values, other than the 3.9k normally used with the HPFF8, a single resistor matching the existing EOL can be used as a reference for all the outputs. This feature speeds the installation and the system checkout, because the actual EOL does not need to be located and changed in the circuit. The reference resistor must be within the range of 1.9k to 25k. Features • Four (4) supervised notification application circuits (NACs) capable of supplying +24VDC at 3.0 amp maximum each • NAC output circuits may be configured as any of the following: - Four Class B (Style Y) - Two Class B & one Class A - Two Class A (Style Z) - Four Class A with the optional HPP31076 Class A adapter installed • Four field-programmable operational modes • 2.0 amp auxiliary continuously supplied output • Two (2) fully supervised input/output control circuits • Temporal coding and sync protocols compatible with the following notification appliance brands: - System Sensor - Faraday - Gamewell - Amseco - Cooper-Wheelock - Gentex • Supervised AC input, battery voltage, auxiliary output, charger, and earth ground faults • Trouble indication for supervision of the following: - NAC circuits - Auxiliary output - AC input - Charger - Battery voltage - Open contacts in the initiat- ing device signal inputs (for FACP trouble notification) - Earth ground faults by individual status LED's • Separate Trouble and AC Fail Form-C relay Contacts HPFF8 An ISO 9001-2000 Company 7315-1637:0102 SIGNALING S24562 FM APPROVED GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9021-60521 Rev. B page 2 of 2 www.gamewell-fci.com Features (Continued) • The Trouble Form-C relay contacts selectable for imme- diate or a 2 hour delay with AC failure • 26 AH battery charger capability; the wall cabinet supports two 12V 18AH batteries, while the multi-pack equipment cabinets supports two 12V 12AH batteries. • NAC Overload protection and indication • Up to four chassis mount units (HPFF8CM) can be installed in the SBB-D4 backbox • Wall mount units can be configured to internally house the following: - one AOM-2SF single control module - one AOM-2R single relay module Specifications Primary Input Power:120VAC/60Hz, 3.6A or 220VAC/50Hz, 1.5A Secondary Power:24 volt operation: two (2), 7-24 AH batteries Battery Charging Capacity:Up to 26 AH batteries mounted Battery Space: HPFF8 Cabinet:Up to two 18AH batteries SBB-D4 Cabinet:Up to two 12AH batteries per supply Total Output Power:8.0A max Standby Current: 0.030 A Auxiliary Power Output:0.15A under all conditions 2.0A if load is removed dur- ing operation (external relay or AC Fail Relay is required) Specifications (Continued) NAC Output Ratings:24VDC fully regulated, 3.0A max per circuit (8.0A total) End-of-Line Resistor Range: 2K to 25k ohm, ½ watt Common Trouble Relay/AC Fail Relay:2.0A at 28VDC or 120VAC Input Control Circuit:16-30VDC @ 5mA min. Temperature Rating:32°F to 120°F (0°C to 49°C Relative Humidity:10% to 93% non-condensing Cabinet Dimensions: HPFF8 Cabinet:16.65” W x 19.0” H x 5.2” D (42.29 W x 48.26 H 13.23 D cm) SBB-D4 Cabinet:24” W x 45.9” H x 5.15” D (60.96 W x 116.52 H x 13.1D cm) Ordering Information Part Number Description HPFF8 8A fire rated power supply operating at 120VAC/60 Hz. Unit includes red enclosure with HPP lock and key HPFF8CM 8A fire rated power supply - chassis mounted operating at 120VAC/60 Hz. Unit includes mounting hardware for installation in the SBB-D4 enclosure HPFF8E 8A fire rated power supply operating at 240VAC/50 Hz HPFF8CME 8A fire rated power supply chassis mounted operating at 240VAC/50 Hz HPP31076 Class A (Style Z) NAC module FCI-VDR-D4 Vented door, PK-625 lock and key for SBB-D4 backbox, black SBB-D4 Backbox, accepts up to 4 chassis, black Standby 0.075 A Alarm 0.696 A Qty Draw Non-Alarm Qty Draw Alarm 1 x 0.07500 0.07500 1 x 0.20600 0.20600 4 x 0.00000 0.00000 4 x 0.05400 0.21600 0 x 0.00000 0 x 0.07100 2 x 0.00000 0.00000 2 x 0.13700 0.27400 0 x 0.00000 0 x 0.16100 0 x 0.00000 0 x 0.05400 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0.00000 0.49000 0 x 0.00000 0 x 0.05400 0 x 0.00000 0 x 0.07100 0 x 0.00000 0 x 0.13700 0 x 0.00000 0 x 0.21700 0 x 0.00000 0 x 0.05400 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0.00000 0.00000 0 x 0.00000 0 x 0.05400 0 x 0.00000 0 x 0.07100 0 x 0.00000 0 x 0.13700 0 x 0.00000 0 x 0.16100 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0.00000 0.00000 0 x 0.00000 0 x 0.05400 0 x 0.00000 0 x 0.07100 0 x 0.00000 0 x 0.13700 0 x 0.00000 0 x 0.18500 0 x 0.00000 0 x 0.05400 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0.00000 0.00000 0 x 0.00000 0 x 0.03000 0 x 0.03700 0 x 0.00850 0 x 0.02000 0 x 0.04000 0 x 0.05000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0.00000 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 3. . PC2WL15 TB4 Totals (Max 2 Amps): PC2WL95 PC2WL15 PC2WL30 PC2WL75 NAC #4 Totals (Max 3 Amps): Other compatible devices Other compatible devices Total Non-Alarm Load: Other compatible devices 7. Compatible Devices not listed 0.075 6. Auxiliary Power PR-3 FIRERAY5000 CO1224TR E3SMRCO/E3SA Auxiliary Device Total Alarm Load: Secondary Alarm CurrentSecondary Non-Alarm Current 1. System Modules 1. HS-1 HPFF8 Main Circuit Board 0.696 PC2WL95 PC2WL30 SCWL15 NAC #2 Totals (Max 3 Amps): Device PC2WL15 PC2WL75 PC2WL150 System Current Draw - HPFF8 Total Current NAC #3 Totals (Max 3 Amps): PC2WL115 SCWL15 4. . PC2WL15 PC2WL30 PC2WL75 PC2WL30 PC2WL75 SCWL15 2. . NAC #1 Totals (Max 3 Amps): Protected Premises:Date:5.16.2022 Address: City:State:ID Zip:83480 Prepared By:Phone:801.468.8300 Address:Email: City:State:UT Zip:84115 Secondary Load Requirements 2.23 Amp Hours Total (AH) 1.80 0.06 1.86 x 1.2 2.23 AH 8 Amp Hours TRUE 1481 S Major Street Office@nelsonfire.com Salt Lake City Secondary Power Requirements BYU-I Benson Building Remodel 525 South Center Street Rexburg Nelson Fire Systems HPFF8 Power Supply 24 hoursx Total Secondary Load from the calculation table below. 0.075 A Current Draw Secondary Standby Load Select batteries from the list below. Battery Selection 8.0 AH BAT-1270 Battery (12 volt) Derating factor Secondary Load Requirements Total Secondary Load Secondary Alarm Load x0.696 A Required Alarm Time (hours) 0.084 hours Time (hours) Required Standby TimeT w Battery Distribution Chart Comments 5.77 2.16 0.07 Secondary Standby Load (AH) * Derating Factor 1. Batteries will fit in the FACP cabinet. Secondary Alarm Load (AH) * Derating FactorSecondary Alarm Load Shows amp-hour distribution of your selections. 3. The selected batteries (8AH) are within the charger range of this power supply (7-26AH). Spare Battery Capacity Secondary Standby Load 2. Selected battery size meets secondary load requirements. Battery Selection (AH) - Secondary Load Requirements (AH) Spare Battery Capacity 72% Secondary Standby Load 27% Secondary Alarm Load 1% Spare Battery Capacity Secondary Standby Load Secondary Alarm Load Page 3 of 115 BYUI Benson -Voltage Drop Calculation Report POWER SOURCE Power Source CIRCUIT 1 HPFF8 CLASS B Brand Gamewell-FCI Model Number HPFF8 CLASS B Nominal System Voltage 20.4 VOLTS NAC Circuit! I 0.49 AMPS I CLASS A I AWG I 6 Devices I 0.49 AMPS USED I 0.45 VOLTAGE DROP # ' Device Model ' Candela ' Pattern ' Volume ' Tone ' CURRENT (AM PS) ' Dist from prev device ' Volts 1 PC2WL 15 Temporal Low Electromechanical 0.054 20 20.34 2 PC2WL 15 Temporal Low Electromechanical 0.054 40 20.23 3 PC2WL 15 Temporal Low Electromechanical 0.054 40 20.13 4 PC2WL 15 Temporal Low Electromechanical 0.054 40 20.05 5 PC2WL 75 Temporal Low Electromechanical 0.137 40 19.98 6 PC2WL 75 Temporal Low Electromechanical 0.137 40 19.95 BENSON BUILDING REMODEL BRIGHAM YOUNG UNIVERSITY- IDAHO FIRE ALARM SYSTEM JPK XXXX TDT (ANSI B) 1/16" = 1' XXXX XXXX BE N S O N B U I L D I N G R E M O D E L BR I G H A M Y O U N G U N I V E R S I T Y - I D A H O 52 5 S O U T H C E N T E R S T R E E T RE X B U R G , I D A H O 8 3 4 8 0 FI R E A L A R M S Y S T E M PROJECT COVER SHEET FA-C-01 NELSON FIRE SYSTEMS DRAWN BY: DESIGNED BY: APPROVED BY: DATE: SCALE: PROJECT NO: REVISION NO: DRAWING NAME: NO T E : NF S D R A W I N G S A R E B A S E D O N T H E P R O J E C T AR C H I T E C T U R E / E N G I N E E R ( A / E ) P L A N S A N D SP E C I F I C A T I O N S F U R N I S H E D T O N F S . A / E I S S O L E L Y RE S P O N S I B L E ( N O T N F S ) F O R T H E T Y P E , S I Z E , LO C A T I O N , A N D S U I T A B I L I T Y O F A L L F I R E A L A R M S , CO N T R O L P A N E L S , A N D O T H E R D E V I C E S S H O W N O N TH E A / E P L A N S . N F S D R A W I N G S A R E T O S H O W O N L Y TH E W I R I N G D I A G R A M S B E T W E E N F I R E A L A R M DE V I C E S A N D C O N T R O L P A N E L S . N F S I S N O T RE S P O N S I B L E F O R T H E I N F O R M A T I O N S H O W N O N T H E A/ E P L A N S . NELSON FIRE SYSTEMS PAGE: BYU-I BENSON REM 2022 C.DWG 4/12/2022 8:43:22 AM INDEX OF DRAWINGS PAGE 1 2 3 FA-C-01 FA-R-01 FA-1-01 SHEET #LEVEL PROJECT COVER SHEET / INDEX OF DRAWINGS FIRE ALARM BUILDING RISER DIAGRAM / MATRIX LEVEL 1 DEVICE SCHEDULE COUNTS HORN/STROBE- CEILING PC2WL DESCRIPTION FIRE ALARM CONTROL UNIT EXISTING TRANSPONDER PANEL EXISTING HS FACU TRAN C 4 SQ. 2-1/8" DEEP BOX MINIMUM w/SINGLE GANG MUD RING EXISTING TO REMAIN EXISTING TO REMAIN PART NUMBER MOUNTING REQUIREMENTSYMBOL 6 SHEET CONTENTS NOTIFICATION CIRCUIT BUILDING CONSTRUCTION TYPE: IIB BUILDING SQUARE FOOTAGE: 3,414 FT 2 LEVEL 1 DO NOT USE SHIELDED WIRE ON ADDRESSABLE CIRCUIT JPK XXXX TDT (ANSI B) 1/16" = 1' XXXX XXXX BE N S O N B U I L D I N G R E M O D E L BR I G H A M Y O U N G U N I V E R S I T Y - I D A H O FI R E A L A R M R I S E R D I A G R A M / M A T R I X 52 5 S O U T H C E N T E R S T R E E T RE X B U R G , I D A H O 8 3 4 8 0 FI R E A L A R M S Y S T E M FIRE RISER DIAGRAM / MATRIX FA-R-01 NELSON FIRE SYSTEMS DRAWN BY: DESIGNED BY: APPROVED BY: DATE: SCALE: PROJECT NO: REVISION NO: DRAWING NAME: NO T E : NF S D R A W I N G S A R E B A S E D O N T H E P R O J E C T AR C H I T E C T U R E / E N G I N E E R ( A / E ) P L A N S A N D SP E C I F I C A T I O N S F U R N I S H E D T O N F S . A / E I S S O L E L Y RE S P O N S I B L E ( N O T N F S ) F O R T H E T Y P E , S I Z E , LO C A T I O N , A N D S U I T A B I L I T Y O F A L L F I R E A L A R M S , CO N T R O L P A N E L S , A N D O T H E R D E V I C E S S H O W N O N TH E A / E P L A N S . N F S D R A W I N G S A R E T O S H O W O N L Y TH E W I R I N G D I A G R A M S B E T W E E N F I R E A L A R M DE V I C E S A N D C O N T R O L P A N E L S . N F S I S N O T RE S P O N S I B L E F O R T H E I N F O R M A T I O N S H O W N O N T H E A/ E P L A N S . NELSON FIRE SYSTEMS PAGE: BYU-I BENSON REM 2022 R.DWG 4/12/2022 8:43:22 AM FACU EXISTING EXISTING BATTERY CABINET LOCATED IN MECHANICAL ROOM 199 TRANSPONDER EXISTING 15cd HS1-1 15cd HS1-2 15cd HS1-3 15cd HS1-4 75cd HS1-5 75cd HS1-6 2 #14'S HORN/STROBE CIRCUIT HS C HS C HS C HS C HS C HS C E.O.L. 3.9K BUILDING- SMOKE DETECTORS BUILDING- DUCT DETECTORS BUILDING- PULL STATIONS BUILDING- TAMPER SWITCH BUILDING- WATERFLOW SWITCH LOSS OF POWER ANY PANEL OR NAC LOW BATTERY CONDITIONS OPEN CIRCUIT CONDITIONS GROUND FAULTS AL A R M S I G N A L T O F I R E A L A R M D I S P L A Y SU P E R V I S O R Y S I G N A L T O F I R E A L A R M D I S P L A Y TR O U B L E S I G N A L T O F I R E A L A R M D I S P L A Y BU I L D I N G H O R N / S T R O B E S HV A C S H U T - D O W N FI R E / S M O K E D A M P E R S RE L E A S E M A G N E T I C D O O R H O L D E R S AL A R M S I G N A L T O M O N I T O R I N G C O M P A N Y SU P E R V I S O R Y S I G N A L T O M O N I T O R I N G C O M P A N Y TR O U B L E S I G N A L T O M O N I T O R I N G C O M P A N Y FACP ANNUNCIATION NOTIFICATION FIRE SAFETY CONTROL REPORTING SYSTEM INPUTS SYSTEM OUTPUTSFIRE ALARM INPUT/OUTPUT MATRIX [PC2WL] CEILING HORN STROBE TO NEXT DEVICE(+) (-)STROBE CIRCUIT IN OUT(+) (-)FACU FIRE ALARM CONTROL UNIT- EXISTING TRAN TRANSPONDER PANEL- EXISTING HS HORN/STROBE- CEILING6C DEVICE LEGEND DESCRIPTIONCOUNTSSYMBOL EXISTING DEVICE(E) HS HORN/STROBE- WALL JPK XXXX TDT (ANSI B) 1/16" = 1' XXXX XXXX BE N S O N B U I L D I N G R E M O D E L BR I G H A M Y O U N G U N I V E R S I T Y - I D A H O 52 5 S O U T H C E N T E R S T R E E T RE X B U R G , I D A H O 8 3 4 8 0 FI R E A L A R M S Y S T E M LEVEL 1 NOTIFICATION FA-1-01 NELSON FIRE SYSTEMS 801-468-8300 DRAWN BY: DESIGNED BY: APPROVED BY: DATE: SCALE: PROJECT NO: REVISION NO: DRAWING NAME: NO T E : NF S D R A W I N G S A R E B A S E D O N T H E P R O J E C T AR C H I T E C T U R E / E N G I N E E R ( A / E ) P L A N S A N D SP E C I F I C A T I O N S F U R N I S H E D T O N F S . A / E I S S O L E L Y RE S P O N S I B L E ( N O T N F S ) F O R T H E T Y P E , S I Z E , LO C A T I O N , A N D S U I T A B I L I T Y O F A L L F I R E A L A R M S , CO N T R O L P A N E L S , A N D O T H E R D E V I C E S S H O W N O N TH E A / E P L A N S . N F S D R A W I N G S A R E T O S H O W O N L Y TH E W I R I N G D I A G R A M S B E T W E E N F I R E A L A R M DE V I C E S A N D C O N T R O L P A N E L S . N F S I S N O T RE S P O N S I B L E F O R T H E I N F O R M A T I O N S H O W N O N T H E A/ E P L A N S . NELSON FIRE SYSTEMS PAGE: 25'10'50' W E SN 1.INSTALLATION SHALL COMPLY WITH NEC, NFPA 72 AND OTHER APPLICABLE CODES AS REQUIRED BY THE LOCAL AHJ. CLASS "B" WIRING IS REQUIRED. 2.WIRING DEPICTED ON THESE PLAN IS SCHEMATIC - ACTUAL WIRE LOCATIONS MAY DIFFER FROM THESE PLANS. WIRING SHALL BE PERFORMED AS ACTUAL BUILDING CONSTRUCTION CONDITION ALLOW AND TO MINIMIZE PENETRATIONS THROUGH AREA SEPARATION WALLS AND FIRE WALLS. THE USE OF A RACEWAY IS PERMITTED AS LONG AS NO 110V OR HIGHER CABLES ARE IN THE RACEWAY. 3.POWER-LIMITED (PL) AND NONPOWER-LIMITED (NPL) CKT WIRING MUST REMAIN SEPARATED IN CABINET. ALL PL CKT WIRING MUST REMAIN AT LEAST 0.25" AWAY FROM ANY NPL CKT. FURTHERMORE, ALL PL AND NPL CKT WIRING MUST ENTER AND EXIT THE CABINET THROUGH A DIFFERENT KNOCKOUT AND/OR SEPARATE CONDUIT. 4.ONLY FIRE ALARM WIRING IS PERMITTED IN FIRE ALARM CONDUIT. DO NOT USE 110V OR HIGHER IN FIRE ALARM CONDUIT. 5.SMOKE DETECTORS SHALL BE INSTALLED AND COVERED UNTIL TESTING AND FINAL INSPECTION ARE COMPLETED. DO NOT INSTALL SMOKE DETECTORS UNTIL BUILDING IS CLEAN. 6.LOCATE SMOKE DETECTORS A MINIMUM OF THREE (3) FEET FROM MECHANICAL DIFFUSERS. 7.DO NOT USE SHIELDED WIRE ON ADDRESSABLE CKTS. 8.A SMOKE DETECTOR MUST BE IN EVERY ROOM WITH A FIRE ALARM CONTROL UNIT OR POWER SUPPLY. 9.FIRE ALARM CKTS NEED TO BE FREE OF GROUNDS, FAULTS, AND SHORTS PRIOR TO CONNECTION TO FIRE ALARM EQUIPMENT. 10.DEDICATED 120 VAC CKTS SHALL BE MARKED AS "FIRE ALARM CKT" AND BE ACCESSIBLE ONLY TO PERSONNEL. DISCONNECTS FOR THESE CKTS WILL BE RED IN COLOR AND THEIR LOCATION WILL BE NOTED AT EACH CONTROL UNIT. GENERAL NOTES: 4/12/2022 11:23:28 AM BYU-I BENSON REM 2022.DWG WIRE SCHEDULE NOTE DESCRIPTION WIRES A HORN/STROBE CIRCUIT 2 #14'S WIRING NOTE DESCRIPTION A =2 TOTAL CONDUCTORS (2)A =4 TOTAL CONDUCTORS A,(2)B =6 TOTAL CONDUCTORS FACU FIRE ALARM CONTROL UNIT- EXISTING TRAN TRANSPONDER PANEL- EXISTING HS HORN/STROBE- CEILING6C DEVICE LEGEND DESCRIPTIONCOUNTSSYMBOL MECHANICAL ROOM 199 DN DN DN BASIC DRAWING ROOM RM #194 DN IBC MAKER SPACE RM #195 HALLWAY 1-X OFFICE RM #192 OFFICE RM #190 OFFICE RM #190 STAIR & RAMP RM 1-W OFFICE RM #193 VESTIBULE 2-AA STAIRWELL 1-Y STAIRWELL 2-BB HS C HS C HS C HS C HS C HS C FA C U TR A N HS1-6 75cd HS1-5 75cd HS1-4 15cd HS1-2 15cd HS1-1 15cd HS1-3 15cd E.O.L. 3.9K EXISTING DEVICE(E) (E) (E) KEY PLAN *HATCH DENOTES AREA OUT OF SCOPE 1 A SYSTEM NOTES: 1 TO TRANSPONDER LOCATED IN MECHANICAL ROOM 199