Loading...
HomeMy WebLinkAboutPLANS IMPROVEMENTS - 22-00173 - Campus Courtyard - RemodelDR A W N BY : CH K 'D BY : KB / KK BW PL O T DA T E : 7 /19 /20 2 2 EN G I N E E R : RA Y MC D O U G A L , PE DE S C R I P T I O N RE V I S I O N DA T E CO V E R PA G E SH E E T TI T L E : G-101 PLN# 21-06-017 7/19/2022 12 7 E . Ma i n St . Su i t e 11 1 Re x b u r g , ID 83 4 4 0 ww w .so u t h f o r k d e s i g n .co m 20 8 -85 2 -62 3 6 So u t h Fo r k De s i g n Gr o u p , LL C CA M P U S CO U R T Y A R D 26 9 S 5 TH W RE X B U R G , ID A H O THESE PLANS ARE STAMPED/ENGINEERED FOR THE LOCATION SPECIFIED. IF LOCATION CHANGES REENGINEERING IS REQUIRED. Co p y r i g h t 20 2 2 | So u t h f o r k En g i n e e r i n g | Al l Ri g h t s Re s e r v e d . INDEX OF SHEETS G-101 G-201 G-202 A-101 A-102 A-201 A-202 S-101 S-201 R-101 COVER PAGE LIFE SAFETY & OCCUPANCY FIRE SEPARATION EXISTING FLOORPLAN NEW CONSTRUCTION PLAN SECTIONS SECTIONS WALL FRAMING PLAN STRUCTURAL CEILING PLAN DETAILS PROJECT LOCATION REXBURG 7 VICINITY MAP NOT TO SCALE CAMPUS COURTYARD IMPROVEMENTS ENERGY COMPLIANCE PRESCRIPTIVE METHOD: CLIMATE ZONE 6 MIN R22 IN WALLS MIN R49 IN ATTIC MIN .30 WINDOW U-FACTOR MIN .30 DOOR U-FACTOR CODE ANALYSIS: GOVERNING BODY: CITY OF REXBURG BUILDING CODE: IBC 2018 OCCUPANCY CLASSIFICATION: ASSEMBLY GROUP A-3 CONSTRUCTION TYPE: V-B SPRINKLER SYSTEM: NOT REQUIRED FIRE SEPARATION: 2-HOUR (R-2 TO A-3) DRAFTSTOPPING/FIREBLOCKING: REQUIRED # OF STORIES ABOVE GRADE: 1 DR A W N BY : CH K 'D BY : KB / KK BW PL O T DA T E : 7 /19 /20 2 2 EN G I N E E R : RA Y MC D O U G A L , PE DE S C R I P T I O N RE V I S I O N DA T E LI F E SA F E T Y & OC C U P A N C Y SH E E T TI T L E : G-201 PLN# 21-06-017 7/19/2022 12 7 E . Ma i n St . Su i t e 11 1 Re x b u r g , ID 83 4 4 0 ww w .so u t h f o r k d e s i g n .co m 20 8 -85 2 -62 3 6 So u t h Fo r k De s i g n Gr o u p , LL C CA M P U S CO U R T Y A R D 26 9 S 5 TH W RE X B U R G , ID A H O THESE PLANS ARE STAMPED/ENGINEERED FOR THE LOCATION SPECIFIED. IF LOCATION CHANGES REENGINEERING IS REQUIRED. Co p y r i g h t 20 2 2 | So u t h f o r k En g i n e e r i n g | Al l Ri g h t s Re s e r v e d . 2,505 sq ft 11 107 sq ft 65 sq ft B 2 A 1 3 1 F 857 sq ft EGRESS DOOR: OCCUPANT LOAD: 18 REQUIRED WIDTH: 3.6" CLR. WIDTH: 36" OK EXIT EXIT EGRESS DOOR: OCCUPANT LOAD: 170 REQUIRED WIDTH: 34" CLR. WIDTH: 36" OK 42' TRAVEL DISTANCE 58' TRAVEL DISTANCE R-2 OCCUPANCY - EXISTING APARTMENT 18 OCC. 3 OCC. 167 OCC. UNCONCENTRATED ASSEMBLY IBC TABLE 1004.5 OCCUPANT LOAD FACTOR: 15 NET 2,505 SQ. FT. STORAGE ROOM 65 SQ. FT. EXERCISE ROOMS IBC TABLE 1004.5 OCCUPANT LOAD FACTOR: 50 GROSS 857 SQ. FT. RESIDENTIAL KITCHEN 107 SQ. FT. 1 LIFE SAFTEY & OCCUPANCY PLAN SCALE: 1/4" = 1'-0" DR A W N BY : CH K 'D BY : KB / KK BW PL O T DA T E : 7 /19 /20 2 2 EN G I N E E R : RA Y MC D O U G A L , PE DE S C R I P T I O N RE V I S I O N DA T E FI R E SE P A R A T I O N SH E E T TI T L E : G-202 PLN# 21-06-017 7/19/2022 12 7 E . Ma i n St . Su i t e 11 1 Re x b u r g , ID 83 4 4 0 ww w .so u t h f o r k d e s i g n .co m 20 8 -85 2 -62 3 6 So u t h Fo r k De s i g n Gr o u p , LL C CA M P U S CO U R T Y A R D 26 9 S 5 TH W RE X B U R G , ID A H O THESE PLANS ARE STAMPED/ENGINEERED FOR THE LOCATION SPECIFIED. IF LOCATION CHANGES REENGINEERING IS REQUIRED. Co p y r i g h t 20 2 2 | So u t h f o r k En g i n e e r i n g | Al l Ri g h t s Re s e r v e d . 4 G-202 2 G-202 3 G-202 2-HOUR FIRE-RATING REQUIRED BETWEEN RESIDENTIAL AND BUSINESS OCCUPANCIES PER IBC TABLE 508.4 WHEN NON-SPRINKLERED, SEE FIREWALL SECTIONS & DETAILS OVER CMU WALL PARALLEL TO ROOF PURLINS, TYP. PERPENDICULAR TO ROOF PURLINS, TYP. EXISTING 2X T&G ROOF SHEATHING ROXUL SAFE ROCKWOOL INSULATION IN PURLIN CAVITY EXISTING ROOF PURLINS BLOWN-IN CEILING INSULATION 2" C-CHANNEL RUNNER 2X4 STUD WALL, HEIGHT VARIES 2" C-CHANNEL RUNNER. ATTACH TO CONCRETE SLAB W/ POWER-DRIVEN FASTENERS @ 24" O.C. EXISTING 2X6 STUD WALL GYP. BD. CEILING 1/2" GYP. BD. BOTTOM PLATE EXISTING CONCRETE SLAB DOUBLE TOP PLATE 2X4 FULL-HEIGHT STUD WALL, HEIGHT VARIESEXISTING INSULATION INSULATION (2) LAYERS OF 1" GYP. BD. (2) LAYERS OF 1" GYP. BD. 2X CEILING JOISTS EXISTING CEILING INSULATION BLOCKING IN WALL REQ'D EVERY 10 VERTICAL FEET 2" H-STUD BREAKAWAY CLIP W/ 3/8" PAN HEAD SCREWS, TYP. EXISTING GYP. BD. CEILING SEALANT AS REQUIRED BREAKAWAY CLIP W/ 3/8" PAN HEAD SCREWS, TYP. BLOCKING BETWEEN PURLINS @ 14" O.C. FOR C-CHANNEL ATTACHMENT EXISTING 2X T&G ROOF SHEATHING ROXUL SAFE ROCKWOOL INSULATION IN PURLIN CAVITY EXISTING ROOF PURLINS BLOWN-IN CEILING INSULATION 2" C-CHANNEL RUNNER 2X4 STUD WALL, HEIGHT VARIES EXISTING 2X6 STUD WALL GYP. BD. CEILING 1/2" GYP. BD. BOTTOM PLATE EXISTING CONCRETE SLAB DBL. TOP PLATE 2X4 FULL-HEIGHT STUD WALL, HEIGHT VARIES EXISTING INSULATION INSULATION (2) LAYERS OF 1" GYP. BD. (2) LAYERS OF 1" GYP. BD. 2X CEILING JOISTS, CEILING HEIGHT VARIES EXISTING CEILING INSULATION BLOCKING IN WALL REQ'D EVERY 10 VERTICAL FEET 2" H-STUD BREAKAWAY CLIP W/ 3/8" PAN HEAD SCREWS, TYP. EXISTING GYP. BD. CEILING BREAKAWAY CLIP W/ 3/8" PAN HEAD SCREWS, TYP. BREAKAWAY CLIP W/ 3/8" PAN HEAD SCREWS, TYP. METAL ROOF SEALANT AS REQUIRED 2" C-CHANNEL RUNNER. ATTACH TO CONCRETE SLAB W/ POWER-DRIVEN FASTENERS @ 24" O.C. EXISTING 2X T&G ROOF SHEATHING ROXUL SAFE ROCKWOOL INSULATION EXISTING ROOF PURLINS EXISTING STEEL TRUSS BLOWN-IN CEILING INSULATION 2" C-CHANNEL. CURVE TO MATCH ROOF PURLINS & ATTACH @ EA. PURLIN (2) LAYERS OF 1" GYP. BD. EXISTING CMU WALL DOUBLE TOP PLATE 2X4 FURRING WALL GYP. BD. CEILING 1/2" GYP. BD. BOTTOM PLATE EXISTING CONCRETE SLAB SEALANT AS REQUIRED 2" C-CHANNEL RUNNER. ATTACH TO CMU WALL W/ POWER-DRIVEN FASTENERS @ 24" O.C. 1 FIRE SEPARATION KEY PLAN SCALE: 1/8" = 1'-0" 2 FIRE SEPARATION @ PARALLEL NOT TO SCALE 3 FIRE SEPARATION @ PERPENDICULAR NOT TO SCALE 4 FIRE SEPARATION @ CMU WALL NOT TO SCALE DR A W N BY : CH K 'D BY : KB / KK BW PL O T DA T E : 7 /19 /20 2 2 EN G I N E E R : RA Y MC D O U G A L , PE DE S C R I P T I O N RE V I S I O N DA T E EX I S T I N G FL O O R P L A N SH E E T TI T L E : A-101 PLN# 21-06-017 7/19/2022 12 7 E . Ma i n St . Su i t e 11 1 Re x b u r g , ID 83 4 4 0 ww w .so u t h f o r k d e s i g n .co m 20 8 -85 2 -62 3 6 So u t h Fo r k De s i g n Gr o u p , LL C CA M P U S CO U R T Y A R D 26 9 S 5 TH W RE X B U R G , ID A H O THESE PLANS ARE STAMPED/ENGINEERED FOR THE LOCATION SPECIFIED. IF LOCATION CHANGES REENGINEERING IS REQUIRED. Co p y r i g h t 20 2 2 | So u t h f o r k En g i n e e r i n g | Al l Ri g h t s Re s e r v e d . 9' 5' 3' 8' 8' 8' 9' 17 ' 16 ' 17 ' 102'-8" 17'17'-2"17'-2"17'-2"17'-2"17' 50 ' 13 ' - 8 " 8' 5' - 2 " 22 ' - 6 " 7'-2"5'-2"13'-4"59'-8" 3 A -20 1 3 A -20 1 1 A-202 1 A-202 1 A -20 1 1 A -20 1 2 A -20 1 2 A -20 1 2 A-202 2 A-202 EXISTING ELECTRICAL EQUIPMENT EXISTING WAREHOUSE EXISTING APARTMENT, INTERIOR NOT SHOWN 1 EXISTING PLAN SCALE: 1/4" = 1'-0" ADDITION & REMODEL NOTE: IT IS THE RESPONSIBILITY OF THE OWNER/ BUILDER TO VERIFY THE DIMENSIONS, ROOF PITCHES, FLOOR ELEVATIONS, AND INTEGRATION OF THE OVERALL DESIGN WITH THE EXISTING STRUCTURE. DR A W N BY : CH K 'D BY : KB / KK BW PL O T DA T E : 7 /19 /20 2 2 EN G I N E E R : RA Y MC D O U G A L , PE DE S C R I P T I O N RE V I S I O N DA T E NE W CO N S T R U C T I O N PL A N SH E E T TI T L E : A-102 PLN# 21-06-017 7/19/2022 12 7 E . Ma i n St . Su i t e 11 1 Re x b u r g , ID 83 4 4 0 ww w .so u t h f o r k d e s i g n .co m 20 8 -85 2 -62 3 6 So u t h Fo r k De s i g n Gr o u p , LL C CA M P U S CO U R T Y A R D 26 9 S 5 TH W RE X B U R G , ID A H O THESE PLANS ARE STAMPED/ENGINEERED FOR THE LOCATION SPECIFIED. IF LOCATION CHANGES REENGINEERING IS REQUIRED. Co p y r i g h t 20 2 2 | So u t h f o r k En g i n e e r i n g | Al l Ri g h t s Re s e r v e d . 11 B 2 A 1 3 1 F 102'-8" 50 ' 3 A -20 1 3 A -20 1 1 A-202 1 A-202 1 A -20 1 1 A -20 1 2 A -20 1 2 A -20 1 2 A-202 2 A-202 TOE-KICK HEATER TO BE INSTALLED TO PREVENT FREEZING MECH. BATH BATH EXISTING APARTMENT, INTERIOR NOT SHOWN SPORT COURTS 50'-9" x 49'-4" FITNESS ROOM 34'-1" x 21'-5" KITCHEN 8'-4" x 12'-8" STORAGE 7'-10" x 8'-1" WINDOW SCHEDULE ID A B TYPE TBD TBD QTY 1 1 SIZE W 7'-9" 18' HT 4' 12' NOTES 5-PANEL GLASS W/ SILICONE JOINTS DOOR SCHEDULE ID 1 2 3 QTY 4 1 1 LOCATION Interior Interior Interior FIRE RATING DOOR W 3' 6' 12'-7" HT 7' 7' 9' NOTES STOREFRONT GLASS DOUBLE DOOR W/ FULL-HEIGHT TRANSOM WINDOW TRIPLE BYPASS BARN DOOR 1 NEW CONSTRUCTION SCALE: 1/4" = 1'-0" ADDITION & REMODEL NOTE: IT IS THE RESPONSIBILITY OF THE OWNER/ BUILDER TO VERIFY THE DIMENSIONS, ROOF PITCHES, FLOOR ELEVATIONS, AND INTEGRATION OF THE OVERALL DESIGN WITH THE EXISTING STRUCTURE. DR A W N BY : CH K 'D BY : KB / KK BW PL O T DA T E : 7 /19 /20 2 2 EN G I N E E R : RA Y MC D O U G A L , PE DE S C R I P T I O N RE V I S I O N DA T E SE C T I O N S SH E E T TI T L E : A-201 PLN# 21-06-017 7/19/2022 12 7 E . Ma i n St . Su i t e 11 1 Re x b u r g , ID 83 4 4 0 ww w .so u t h f o r k d e s i g n .co m 20 8 -85 2 -62 3 6 So u t h Fo r k De s i g n Gr o u p , LL C CA M P U S CO U R T Y A R D 26 9 S 5 TH W RE X B U R G , ID A H O THESE PLANS ARE STAMPED/ENGINEERED FOR THE LOCATION SPECIFIED. IF LOCATION CHANGES REENGINEERING IS REQUIRED. Co p y r i g h t 20 2 2 | So u t h f o r k En g i n e e r i n g | Al l Ri g h t s Re s e r v e d . 2 G-202 14 ' , FI E L D VE R I F Y 18 '-9 7 /8 ", FI E L D VE R I F Y 9 '-1 1 /8 " FI E L D VE R I F Y EX I S T I N G WA L L HT . 9 '-8 3 /4 " CEILING JOISTS, SEE S-201 EXISTING APARTMENT, INTERIOR NOT SHOWN ADA BATHROOM EXERCISE ROOM 2-HOUR FIRE SEPARATION PARALLEL TO ROOF PURLINS 2 G-202 14 ' FI E L D VE R I F Y 19 '-9 3 /8 ", FI E L D VE R I F Y 9 '-1 1 /8 " FI E L D VE R I F Y EX I S T I N G WA L L HT . 10 '-8 1 /4 " EXISTING APARTMENT, INTERIOR NOT SHOWN EXERCISE ROOM 2-HOUR FIRE SEPARATION PARALLEL TO ROOF PURLINS DECORATIVE PANELING BEHIND EXPOSED STEEL TRUSS SPORT COURTS KITCHEN (BEHIND) 1 SECTION @ ADA BATHROOM SCALE: 1/4" = 1'-0" 2 SECTION @ EXERCISE ROOM SCALE: 1/4" = 1'-0" 3 SECTION @ SPORT COURTS SCALE: 1/4" = 1'-0" ADDITION & REMODEL NOTE: IT IS THE RESPONSIBILITY OF THE OWNER/ BUILDER TO VERIFY THE DIMENSIONS, ROOF PITCHES, FLOOR ELEVATIONS, AND INTEGRATION OF THE OVERALL DESIGN WITH THE EXISTING STRUCTURE. DR A W N BY : CH K 'D BY : KB / KK BW PL O T DA T E : 7 /19 /20 2 2 EN G I N E E R : RA Y MC D O U G A L , PE DE S C R I P T I O N RE V I S I O N DA T E SE C T I O N S SH E E T TI T L E : A-202 PLN# 21-06-017 7/19/2022 12 7 E . Ma i n St . Su i t e 11 1 Re x b u r g , ID 83 4 4 0 ww w .so u t h f o r k d e s i g n .co m 20 8 -85 2 -62 3 6 So u t h Fo r k De s i g n Gr o u p , LL C CA M P U S CO U R T Y A R D 26 9 S 5 TH W RE X B U R G , ID A H O THESE PLANS ARE STAMPED/ENGINEERED FOR THE LOCATION SPECIFIED. IF LOCATION CHANGES REENGINEERING IS REQUIRED. Co p y r i g h t 20 2 2 | So u t h f o r k En g i n e e r i n g | Al l Ri g h t s Re s e r v e d . 3 G-202 17 ' - 4 1/ 8 " , VA R I E S INSTALL DECORATIVE INDUSTRIAL PANELING BEHIND WEBBING OF LAST EXPOSED STEEL TRUSS PER CONTRACTOR EXISTING APARTMENT, INTERIOR NOT SHOWN STORAGE ROOM SPORT COURTS 2-HOUR FIRE SEPARATION PERPENDICULAR TO ROOF PURLINS 4 G-202 6 R-101 14 ' FI E L D VE R I F Y EXISTING ARCHED STEEL TRUSS, TYP. EXISTING ROOF PURLINS, TYP. EXISTING CMU BUTTRESS, TYP. INSTALL DECORATIVE INDUSTRIAL PANELING BEHIND WEBBING OF LAST EXPOSED STEEL TRUSS PER CONTRACTOR EXISTING APARTMENT, INTERIOR NOT SHOWN 2-HOUR FIRE SEPARATION OVER EXISTING CMU WALL EXERCISE ROOM SPORT COURTS WINDOW TO STEEL TRUSS 1 CROSS SECTION @ STORAGE ROOM SCALE: 1/4" = 1'-0" 2 CROSS SECTION @ EXERCISE ROOM SCALE: 1/4" = 1'-0" ADDITION & REMODEL NOTE: IT IS THE RESPONSIBILITY OF THE OWNER/ BUILDER TO VERIFY THE DIMENSIONS, ROOF PITCHES, FLOOR ELEVATIONS, AND INTEGRATION OF THE OVERALL DESIGN WITH THE EXISTING STRUCTURE. DR A W N BY : CH K 'D BY : KB / KK BW PL O T DA T E : 7 /19 /20 2 2 EN G I N E E R : RA Y MC D O U G A L , PE DE S C R I P T I O N RE V I S I O N DA T E WA L L FR A M I N G PL A N SH E E T TI T L E : S-101 PLN# 21-06-017 7/19/2022 12 7 E . Ma i n St . Su i t e 11 1 Re x b u r g , ID 83 4 4 0 ww w .so u t h f o r k d e s i g n .co m 20 8 -85 2 -62 3 6 So u t h Fo r k De s i g n Gr o u p , LL C CA M P U S CO U R T Y A R D 26 9 S 5 TH W RE X B U R G , ID A H O THESE PLANS ARE STAMPED/ENGINEERED FOR THE LOCATION SPECIFIED. IF LOCATION CHANGES REENGINEERING IS REQUIRED. Co p y r i g h t 20 2 2 | So u t h f o r k En g i n e e r i n g | Al l Ri g h t s Re s e r v e d . 8' - 1 0 " 13 ' - 2 " 7' - 4 " 20 ' 49 ' - 4 " 2' - 3 " 6' - 7 " 3' - 8 " 3' - 8 " 9' - 6 " 10 ' - 6 " 11 B 2 A 1 3 1 F 102'-8" 17'34'-4"51'-4" 19 '-10 1 /4 " 1 '-8 3 /4 "4'-103/4" 8 '-10 1 /2 " 5' - 5 " 7 '-9 1 /2 " 27 '-3 1 /2 " 7'-7"5'-2"6'-31/2"6'-81/2"8'-7" 50 ' 50 ' 102'-8" 3 A -20 1 3 A -20 1 1 A-202 1 A-202 1 A -20 1 1 A -20 1 2 A -20 1 2 A -20 1 2 A-202 2 A-202 FIR-IN 2X6 INSULATED WALL FIR-IN 2X4 WALL CENTER WALL DIRECTLY BETWEEN MASONRY COLUMNS AND STEEL TRUSS ABOVE HSS 8"X12"X1/4" COLUMN, TYP. MECH. BATH BATH EXISTING APARTMENT, INTERIOR NOT SHOWN HUCQ1.81/11 WELDED TO STEEL COLUMN SPORT COURTS 50'-9" x 49'-4" FITNESS ROOM 34'-1" x 21'-5" KITCHEN 8'-4" x 12'-8" STORAGE 7'-10" x 8'-1" 8 R-101 (1 ) 11 -7 /8 " MI C R O L A M LV L HE A D E R WINDOW SCHEDULE ID A B TYPE TBD TBD QTY 1 1 SIZE W 7'-9" 18' HT 4' 12' NOTES 5-PANEL GLASS W/ SILICONE JOINTS DOOR SCHEDULE ID 1 2 3 QTY 4 1 1 LOCATION Interior Interior Interior FIRE RATING DOOR W 3' 6' 12'-7" HT 7' 7' 9' NOTES STOREFRONT GLASS DOUBLE DOOR W/ FULL-HEIGHT TRANSOM WINDOW TRIPLE BYPASS BARN DOOR 1 WALL FRAMING PLAN SCALE: 1/4" = 1'-0" ADDITION & REMODEL NOTE: IT IS THE RESPONSIBILITY OF THE OWNER/ BUILDER TO VERIFY THE DIMENSIONS, ROOF PITCHES, FLOOR ELEVATIONS, AND INTEGRATION OF THE OVERALL DESIGN WITH THE EXISTING STRUCTURE. DR A W N BY : CH K 'D BY : KB / KK BW PL O T DA T E : 7 /19 /20 2 2 EN G I N E E R : RA Y MC D O U G A L , PE DE S C R I P T I O N RE V I S I O N DA T E ST R U C T U R A L CE I L I N G PL A N SH E E T TI T L E : S-201 PLN# 21-06-017 7/19/2022 12 7 E . Ma i n St . Su i t e 11 1 Re x b u r g , ID 83 4 4 0 ww w .so u t h f o r k d e s i g n .co m 20 8 -85 2 -62 3 6 So u t h Fo r k De s i g n Gr o u p , LL C CA M P U S CO U R T Y A R D 26 9 S 5 TH W RE X B U R G , ID A H O THESE PLANS ARE STAMPED/ENGINEERED FOR THE LOCATION SPECIFIED. IF LOCATION CHANGES REENGINEERING IS REQUIRED. Co p y r i g h t 20 2 2 | So u t h f o r k En g i n e e r i n g | Al l Ri g h t s Re s e r v e d . 7 R-101 3 A -20 1 3 A -20 1 1 A-202 1 A-202 1 A -20 1 1 A -20 1 2 A -20 1 2 A -20 1 2 A-202 2 A-202 2X 1 0 CE I L I N G JO I S T S @ 16 " O. C . (S H O W N ) OR 9. 5 " TJ I 11 0 JO I S T S @ 24 " O. C . , TY P . LEDGER, TYP. USE 2X10 LEDGER W/ LUS HANGERS OR 9.5" RIM BOARD W/ ITS HANGERS DEPENDING ON CEILING STRUCTURE ATTACH LEDGER W/ LEDGERLOK SCREWS @ BALLOON-FRAMED WALLS + 14'-0" CEILING HT. + 9'-1 1/8" CEILING HT. + 14'-0" CEILING HT. LEDGER ATTACHMENT TO EXISTING STEEL TRUSS WINDOW SCHEDULE ID A B TYPE TBD TBD QTY 1 1 SIZE W 7'-9" 18' HT 4' 12' NOTES 5-PANEL GLASS W/ SILICONE JOINTS DOOR SCHEDULE ID 1 2 3 QTY 4 1 1 LOCATION Interior Interior Interior FIRE RATING DOOR W 3' 6' 12'-7" HT 7' 7' 9' NOTES STOREFRONT GLASS DOUBLE DOOR W/ FULL-HEIGHT TRANSOM WINDOW TRIPLE BYPASS BARN DOOR 1 STRUCTURAL CEILING PLAN SCALE: 1/4" = 1'-0" ADDITION & REMODEL NOTE: IT IS THE RESPONSIBILITY OF THE OWNER/ BUILDER TO VERIFY THE DIMENSIONS, ROOF PITCHES, FLOOR ELEVATIONS, AND INTEGRATION OF THE OVERALL DESIGN WITH THE EXISTING STRUCTURE. DR A W N BY : CH K 'D BY : KB / KK BW PL O T DA T E : 7 /19 /20 2 2 EN G I N E E R : RA Y MC D O U G A L , PE DE S C R I P T I O N RE V I S I O N DA T E DE T A I L S SH E E T TI T L E : R-101 PLN# 21-06-017 7/19/2022 12 7 E . Ma i n St . Su i t e 11 1 Re x b u r g , ID 83 4 4 0 ww w .so u t h f o r k d e s i g n .co m 20 8 -85 2 -62 3 6 So u t h Fo r k De s i g n Gr o u p , LL C CA M P U S CO U R T Y A R D 26 9 S 5 TH W RE X B U R G , ID A H O THESE PLANS ARE STAMPED/ENGINEERED FOR THE LOCATION SPECIFIED. IF LOCATION CHANGES REENGINEERING IS REQUIRED. Co p y r i g h t 20 2 2 | So u t h f o r k En g i n e e r i n g | Al l Ri g h t s Re s e r v e d . 9" MI N 17" MIN 19" MAX 8" MIN 6" MAX 2' - 3 " MI N . 36 " MA X 33 " MI N 36 " MA X 2'-6" MIN. CLR. WIDTH 9" MI N 17" MIN 25" MAX 6" MAX 11" MIN 8" MIN 27 " MI N 34 " MA X ADA HANDLE MIRROR BASIN HEIGHT KNEE CLEARANCE INSULATE EXPOSED PIPES 16" MIN 18" MAX 12" MIN 24" MIN 36" LONG MIN 33 " MI N 36 " MA X 15 " MI N 48 " MA X 40 " MA X TO RE F L E C T I V E SU R F A C E 2'-6" MIN. CLR. WIDTH MIRROR SOAPDISPENSER HIGHEST OPERABLE PART C.L. 17 " MI N 19 " MA X 48 " MA X 7"MIN 9"MAX 15 " MI N 48 " MA X 12"MAX42" LONG MIN 33 " MI N 36 " MA X 1-1/2" CLEARANCE 1.25-2" OUTSIDE DIAMETER 39 " - 4 1 " 18 " MI N CAN BE SINGLE GRAB BAR CAN BE SINGLE GRAB BAR 1 2 4 3 KEYNOTES: 1 - EXISTING STEEL TRUSS 2 - STEEL BOTTOM CHORD, 5-1/2" WIDTH 3 - INTERIOR WINDOW FRAME 4 - WINDOW GLAZING 1 2 3 4 5 67 8 10 9 KEYNOTES: 1 - EXISTING STEEL TRUSS 2 - STEEL BOTTOM CHORD, 5-1/2" WIDTH 3 - 2X10 CEILING JOIST 4 - 2X10 LEDGER 5 - LUS HANGER @ EA. JOIST 6 - 9-1/2" TJI 110 CEILING JOIST OPTION 7 - 9-1/2" RIM BOARD LEDGER OPTION 8 - ITS HANGERS @ EA. JOIST FOR I-JOIST OPTION 9 - 1/2" THROUGH-BOLT @ 24" O.C. 10 - GYPSUM BOARD CEILING 5/ 3 2 " 3/32" 1 2 3 1 3 2 KEYNOTES: 1 - HSS 8"X12"X1/4" STEEL TUBE 2 - HUCQ1.81/11 TO SEAT (1) 11-7/8" LVL 3 - WELD, REFER TO WELD SYMBOLS & DIMENSIONS FLARE-BEVEL GROOVE WELD PLAN VIEW 1" EQUALLY SPACED 1 TYP. DRINKING FOUNTAIN PROFILE NOT TO SCALE 2 TYP. DRINKING FOUNTAIN FRONT NOT TO SCALE 3 TYP. SINK PROFILE ADA NOT TO SCALE 4 TYP. SINK AND TOILET FRONT ADA NOT TO SCALE 5 TYP. TOILET PROFILE NOT TO SCALE 6 WINDOW HEADER NOT TO SCALE 7 CEILING ATTACHMENT NOT TO SCALE 8 LVL HEADER TO STEEL COLUMN NOT TO SCALE