Loading...
HomeMy WebLinkAboutSPEC SHEET - 22-00786 - 11 Sunset circle - Solar Panel.pdfCOMPACT PANEL Size rec Alphα® pure Series Product Specifications α experience performance wp410 22.2 %Efficiency ELIGIBLE LEAD-FREE rohs cOMPLIANT 19.3 w ft2 Ref: PM-DS-12-06-Rev- G 04.22GR GR GR GR GR1821±2.5 [71.7±0.1] 901 [35.5]460 [18.1]975±2.5 [38.4±0.1]1100 [43.3] 1200 [47.2] 30 [1.2] 22.5 [0.9] 671 ±3 [26.4 ±0.12] 11±0.2 [0.43±0.01]6.6±0.2 [0.26±0.01]20.5±0.5 [0.8±0.02] 6.0±0.2 [0.24±0.01] 28 [1.1]1016±2.5 [40 ±0.1]17 [0.7]45 [1.8] 153.7 [6.05] 153.7 [6.05] www.recgroup.com Specifications subject to change without notice.Measurements in mm [in] LOW LIGHT BEHAVIOUR Typical low irradiance performance of module at STC: Irradiance (W/m²)Rel. Efficiency (%)Founded in 1996, REC Group is an international pioneering solar energy company dedicated to empowering consumers with clean, affordable solar power. As Solar’s Most Trusted, REC is committed to high quality, innovation, and a low carbon footprint in the solar materials and solar panels it manufactures. Headquartered in Norway with operational headquarters in Singapore, REC also has regional hubs in North America, Europe, and Asia-Pacific. 85 90 95 100 105 200100 300 400 500 600 700 800 900 1000 GENERAL DATA Cell type:132 half-cut REC heterojunction bifacial cells with lead-free, gapless technology, 6 strings of 22 cells in series Glass:0.13 in (3.2 mm) solar glass with anti-reflective surface treatment in accordance with EN 12150 Backsheet:Highly resistant polymer (black) Frame:Anodized aluminum (black) Junction box:3-part, 3 bypass diodes, lead-free IP68 rated, in accordance with IEC 62790 Connectors:Stäubli MC4 PV-KBT4/KST4 (4 mm²) in accordance with IEC 62852, IP68 only when connected Cable:12 AWG (4 mm²) PV wire, 43+ 47 in (1.1 + 1.2 m) in accordance with EN 50618 Dimensions:71.7 x 40 x 1.2 in (19.91 ft2) / 1821 x 1016 x 30 mm (1.85 m2) Weight:45 lbs (20.5 kg) Origin:Made in Singapore WARRANTY Standard REC ProTrust Installed by an REC Certified Solar Professional No Yes Yes System Size All ≤25 kW 25-500 kW Product Warranty (yrs)20 25 25 Power Warranty (yrs)25 25 25 Labor Warranty (yrs)0 25 10 Power in Year 1 98%98%98% Annual Degradation 0.25%0.25%0.25% Power in Year 25 92%92%92% See warranty documents for details. Conditions apply TEMPERATURE RATINGS * Nominal Module Operating Temperature:44°C (±2 °C) Temperature coefficient of PMAX:-0.26 %/°C Temperature coefficient of VOC:-0.24 %/°C Temperature coefficient of ISC:0.04 %/°C *The temperature coefficients stated are linear values CERTIFICATIONS IEC 61215:2016, IEC 61730:2016, UL 61730 IEC 62804 PID IEC 61701 Salt Mist IEC 62716 Ammonia Resistance UL 61730 Fire Type Class 2 IEC 62782 Dynamic Mechanical Load IEC 61215-2:2016 Hailstone (35mm) IEC 62321 Lead-free acc. to RoHS EU 863/2015 ISO 14001, ISO 9001, IEC 45001, IEC 62941 DELIVERY INFORMATION Panels per pallet:33 Panels per 40 ft GP/high cube container:792 (24 pallets) Panels per 53 ft truck:891 (27 pallets) MAXIMUM RATINGS Operational temperature:-40 ... +85°C Maximum system voltage:1000 V Maximum test load (front): + 7000 Pa (146 lbs/ft2)* Maximum test load (rear):- 4000 Pa (83.5 lbs/ft2)* Max series fuse rating:25 A Max reverse current:25 A * See installation manual for mounting instructions. Design load = Test load / 1.5 (safety factor) Lead-Free REC Alpha Pure Series Product SPECIFICATIONS STC NMOTELECTRICAL DATA Product Code*: RECxxxAA Pure Power Output - PMAX (Wp) 380 385 390 395 400 405 410 Watt Class Sorting - (W)0/+5 0/+5 0/+5 0/+5 0/+5 0/+5 0/+5 Nominal Power Voltage - VMPP (V) 40.9 41.2 41.5 41.8 42.1 42.4 42.7 Nominal Power Current - IMPP (A) 9.30 9.35 9.40 9.45 9.51 9.56 9.61 Open Circuit Voltage - VOC (V) 48.4 48.5 48.6 48.7 48.8 48.9 49.0 Short Circuit Current - ISC (A) 10.17 10.18 10.22 10.25 10.28 10.30 10.35 Power Density (W/ft2)19.1 19.3 19.6 19.8 20.1 20.3 20.6 Panel Efficiency (%) 20.5 20.8 21.1 21.4 21.6 21.9 22.2 Power Output - PMAX (Wp)290 293 297 301 305 309 312 Nominal Power Voltage - VMPP (V) 38.5 38.8 39.1 39.4 39.7 40.0 40.2 Nominal Power Current - IMPP (A) 7.51 7.55 7.59 7.63 7.68 7.72 7.76 Open Circuit Voltage - VOC (V) 45.6 45.7 45.8 45.9 46.0 46.1 46.2 Short Circuit Current - ISC (A) 8.12 8.16 8.20 8.24 8.28 8.32 8.36 Values at standard test conditions (STC: air mass AM 1.5, irradiance 10.75 W/sq ft (1000 W/m²), temperature 77°F (25°C), based on a production spread with a tolerance of PMAX, VOC & ISC ±3% within one watt class. Nominal module operating temperature (NMOT: air mass AM 1.5, irradiance 800 W/m², temperature 68°F (20°C), windspeed 3.3 ft/s (1 m/s). * Where xxx indicates the nominal power class (PMAX) at STC above. IQ8M and IQ8A Microinverters Our newest IQ8 Microinverters are the industry’s first grid-forming microinverters with split-phase power conversion capability to convert DC power to AC power efficiently. The brain of the semiconductor-based microinverter is our proprietary application-specific integrated circuit (ASIC) which enables the microinverter to operate in grid-tied or off-grid modes. This chip is built in advanced 55nm technology with high speed digital logic and has super-fast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems. Part of the Enphase Energy System, IQ8 Series Microinverters integrate with the Enphase IQ Battery, Enphase IQ Gateway, and the Enphase App monitoring and analysis software. IQ8 Series Microinverters redefine reliability standards with more than one million cumulative hours of power-on testing, enabling an industry-leading limited warranty of up to 25 years. Connect PV modules quickly and easily to IQ8 Series Microinverters using the included Q-DCC-2 adapter cable with plug-n-play MC4 connectors. IQ8 Series Microinverters are UL Listed as PV Rapid Shut Down Equipment and conform with various regulations, when installed according to manufacturer’s instructions. Easy to install • Lightweight and compact with plug-n-play connectors • Power Line Communication (PLC) between components • Faster installation with simple two-wire cabling High productivity and reliability • Produce power even when the grid is down • More than one million cumulative hours of testing • Class II double-insulated enclosure • Optimized for the latest high- powered PV modules Grid-forming • Complies with the latest advanced grid support • Remote automatic updates for the latest grid requirements • Configurable to support a wide range of grid profiles • Meets CA Rule 21 (UL 1741-SA) requirements © 2021 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ8 microinverters, and other names are trademarks of Enphase Energy, Inc. Data subject to change. IQ8MA-DS-0003-01-EN-US-2021-10-19 DATA SHEET (1) No enforced DC/AC ratio. See the compatibility calculator at https://link.enphase.com/ module-compatibility (2) Maximum continuous input DC current is 10.6A (3) Nominal voltage range can be extended beyond nominal if required by the utility. (4) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. IQ8M and IQ8A Microinverters INPUT DATA (DC)IQ8M-72-2-US IQ8A-72-2-US Commonly used module pairings1 W 260 – 460 295 – 500 Module compatibility 60-cell/120 half-cell and 72-cell/144 half-cell MPPT voltage range V 33 – 45 36 – 45 Operating range V 25 – 58 Min/max start voltage V 30 / 58 Max input DC voltage V 60 Max DC current2 [module Isc] A 15 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1x1 Ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC)IQ8M-72-2-US IQ8A-72-2-US Peak output power VA 330 366 Max continuous output power VA 325 349 Nominal (L-L) voltage/range3 V 240 / 211 – 264 Max continuous output current A 1.35 1.45 Nominal frequency Hz 60 Extended frequency range Hz 50 – 68 Max units per 20 A (L-L) branch circuit4 11 Total harmonic distortion <5% Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor (adjustable)0.85 leading – 0.85 lagging Peak efficiency %97.6 97.6 CEC weighted efficiency %97 97.5 Night-time power consumption mW 60 MECHANICAL DATA Ambient temperature range -40ºC to +60ºC (-40ºF to +140ºF) Relative humidity range 4% to 100% (condensing) DC Connector type MC4 Dimensions (HxWxD)212 mm (8.3”) x 175 mm (6.9”) x 30.2 mm (1.2”) Weight 1.08 kg (2.38 lbs) Cooling Natural convection – no fans Approved for wet locations Yes Acoustic noise at 1 m <60 dBA Pollution degree PD3 Enclosure Class II double-insulated, corrosion resistant polymeric enclosure Environ. category / UV exposure rating NEMA Type 6 / outdoor COMPLIANCE Certifications CA Rule 21 (UL 1741-SA), UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according to manufacturer’s instructions. IQ8MA-DS-0003-01-EN-US-2021-10-19 The Enphase IQ Combiner 3™ with Enphase IQ Envoy™ consolidates interconnection equipment into a single enclosure and streamlines PV and storage installations by providing a consistent, pre-wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly. Enphase IQ Combiner 3 (X-IQ-AM1-240-3) To learn more about Enphase offerings, visit enphase.com Data Sheet Enphase Networking Smart • Includes IQ Envoy for communication and control • Flexible networking supports Wi-Fi, Ethernet, or cellular • Optional AC receptacle available for PLC bridge • Provides production metering and optional consumption monitoring • Supports Ensemble Communications Kit for communication with Enphase Encharge™ storage and Enphase Enpower™ smart switch Simple • Reduced size from previous combiner • Centered mounting brackets support single stud mounting • Supports back and side conduit entry • Up to four 2-pole branch circuits for 240 VAC plug-in breakers (not included) • 80 A total PV or storage branch circuits Reliable • Durable NRTL-certified NEMA type 3R enclosure • Five-year limited warranty • UL listed To learn more about Enphase offerings, visit enphase.com © 2021 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ Combiner 3, and other trademarks or service names are the trademarks of Enphase Energy, Inc. Data subject to change. 2021-05-20 MODEL NUMBER IQ Combiner 3 X-IQ-AM1-240-3 IQ Combiner 3 with Enphase IQ Envoy™ printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 +/- 0.5%) and optional* consumption monitoring (+/- 2.5%). ACCESSORIES and REPLACEMENT PARTS (not included, order separately) Enphase Mobile Connect™ CELLMODEM-03 (4G/12-year data plan) CELLMODEM-01 (3G/5-year data plan) CELLMODEM-M1 (4G based LTE-M/5-year data plan) Plug and play industrial grade cellular modem with data plan for systems up to 60 microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, where there is adequate cellular service in the installation area.) Consumption Monitoring* CT CT-200-SPLIT Split core current transformers enable whole home consumption metering (+/- 2.5%). * Consumption monitoring is required for Enphase Storage Systems Ensemble Communications Kit COMMS-KIT-01 Installed at the IQ Envoy. For communications with Enphase Encharge™ storage and Enphase Enpower™ smart switch. Includes USB cable for connection to IQ Envoy or Enphase IQ Combiner™ and allows wireless communication with Encharge and Enpower. Circuit Breakers BRK-10A-2-240 BRK-15A-2-240 BRK-20A-2P-240 Supports Eaton BR210, BR215, BR220, BR230, BR240, BR250, and BR260 circuit breakers. Circuit breaker, 2 pole, 10A, Eaton BR210 Circuit breaker, 2 pole, 15A, Eaton BR215 Circuit breaker, 2 pole, 20A, Eaton BR220 EPLC-01 Power line carrier (communication bridge pair), quantity - one pair XA-SOLARSHIELD-ES Replace the default solar shield with this Ensemble Combiner Solar Shield to match the look and feel of the Enphase Enpower™ smart switch and the Enphase Encharge™ storage system XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3 (required for EPLC-01) XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board (PCB) for Combiner 3 ELECTRICAL SPECIFICATIONS Rating Continuous duty System voltage 120/240 VAC, 60 Hz Eaton BR series busbar rating 125 A Max. continuous current rating (output to grid)65 A Max. fuse/circuit rating (output)90 A Branch circuits (solar and/or storage)Up to four 2-pole Eaton BR series Distributed Generation (DG) breakers only (not included) Max. continuous current rating (input from PV)64 A Max. total branch circuit breaker rating (input)80 A of distributed generation / 95 A with IQ Envoy breaker included Envoy breaker 10A or 15A rating GE Q-line/Siemens Type QP /Eaton BR series included Production Metering CT 200 A solid core pre-installed and wired to IQ Envoy MECHANICAL DATA Dimensions (WxHxD)49.5 x 37.5 x 16.8 cm (19.5” x 14.75” x 6.63”). Height is 21.06" (53.5 cm with mounting brackets). Weight 7.5 kg (16.5 lbs) Ambient temperature range -40º C to +46º C (-40º to 115º F) Cooling Natural convection, plus heat shield Enclosure environmental rating Outdoor, NRTL-certified, NEMA type 3R, polycarbonate construction Wire sizes • 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors• 60 A breaker branch input: 4 to 1/0 AWG copper conductors• Main lug combined output: 10 to 2/0 AWG copper conductors• Neutral and ground: 14 to 1/0 copper conductors Always follow local code requirements for conductor sizing. Altitude To 2000 meters (6,560 feet) INTERNET CONNECTION OPTIONS Integrated Wi-Fi 802.11b/g/n Ethernet Optional, 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not included) Cellular CELLMODEM-M1 4G based LTE-M cellular modem (not included). Note that an Enphase Mobile Connect cellular modem is required for all Ensemble installations. COMPLIANCE Compliance, Combiner UL 1741, CAN/CSA C22.2 No. 107.1, 47 CFR, Part 15, Class B, ICES 003 Production metering: ANSI C12.20 accuracy class 0.5 (PV production) Compliance, IQ Envoy UL 60601-1/CANCSA 22.2 No. 61010-1 Enphase IQ Combiner 3 Rapid shutdown is built-in What’s new in NEC 2014? NEC 2014, Section 690.12 applies to PV conductors over 10 feet from the PV array and requires that the conductors power down to 30 volts and 240 volt-amperes within 10 seconds of rapid shutdown initiation. Enphase® Energy // Rapid Shutdown ® To learn more, visit enphase.com The 2014 edition of the National Electrical Code (NEC 2014) added new rapid shutdown requirements for PV systems installed on buildings. Enphase Microinverters fully meet rapid shutdown requirements in the new code without the need to install any additional electrical equipment. Enphase comes standard with rapid shutdown capability Residential Microinverter Commercial Microinverter All Enphase microin- verters, even those that were previously installed, inherently meet rapid shutdown requirements, no additional equipment or workarounds needed Enphase microinverters can safely shut down automatically, leaving only low-voltage DC electricity isolated to the PV module String inverters require work arounds for rapid shutdown Residential String Inverter Commercial String Inverter Work around. Specialized Rapid Shutdown electrical box installed on the roof within 10 feet of array. Work around. String inverter installed on roof, a hostile environment that string inverters are not built to live in.Work around. Shutoff switch that is easily accessible to first responders on the ground. Work around. Extra conduit in installation. September 21, 2022 SnapNrack 775 Fiero Lane, Ste. 200 San Luis Obispo, CA 93401 TEL: (877) 732-2860 Attn.: SnapNrack - Engineering Department Re: SnapNrack pre-engineered PV racking systems:  RL Universal System (Report # 2019-02916A.01 and B.01)  S200 Ground Mount System (Report # 2017-00240-D.02)  UR40 Railed System (Report # 2017-03227.11)  UR60 Railed System (Report # 2018-11940.03)  TopSpeed Deck-Mount Rail-less System (2022-02141) Subject: Engineering certification for the State of Idaho. PZSE, Inc. - Structural Engineers has provided engineering and span tables as presented in the above referenced reports. All information, data, and analysis therein are based on, and comply with, the following building codes and typical specifications: Building Codes: 1. ASCE/SEI 7-16, Minimum Design Loads for Buildings and Other Structures, by American Society of Civil Engineers 2. 2018 International Building Code, by International Code Council, Inc. 3. 2020 Idaho Residential Code, by International Code Council, Inc. 4. AC428 Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic (PV) Panels, November 1, 2012, by ICC-ES 5. Aluminum Design manual 2015, by The Aluminum Association, Inc. 6. ANSI/AWC NDS-2018, National Design Specification for Wood Construction, by the American Wood Council This letter certifies that the design criteria and design methodology for the SnapNrack product span tables are in compliance with the above codes. Please refer to the system specific Engineering Certification Reports (listed above) for system specific design criteria and limitations. If you have any questions on the above, do not hesitate to call. Prepared by: PZSE, Inc. – Structural Engineers Roseville, CA EXP. 08/31/2024 R E E NI REHCAZK.LUAP GNELANOISSEFORP 2762 FOETATS OHADI DESNECILDIGITALLY SIGNED snapnrack.com Ultra Rail Industry leading Wire Management Solutions Single Tool Installation Mounts available for all roof types All SnapNrack Module Clamps & Accessories are compatible with both raiil profi les Start Installing Ultra Rail Today UR-40 UR-60 The Ultimate Value in Rooftop Solar Solar Mounting Solutions © 2016 by SnapNrack Solar Mounting Solutions. All rights reserved 877-732-2860 www.snapnrack.com contact@snapnrack.com SnapNrack_Ultra Rail Sales Brochure_v.1.4 SnapNrack Solar Mounting Solutions are engineered to optimize material use and labor resources and improve overall installation quality and safety. Quality. Innovative. Superior. Unparalleled Wire Management • Open rail channel provides room for running wires resulting in a long-lasting quality install • Industry best wire management o ering includes Junction Boxes, Universal Wire Clamps, MLPE Attachment Kits, and Conduit Clamps • System is fully bonded and listed to UL 2703 Standard © 2019 by SnapNrack Solar Mounting Solutions. All rights reserved 877-732-2860 www.snapnrack.com contact@snapnrack.com SnapNrack Ultra Rail System A sleek, straightforward rail solution for mounting solar modules on all roof types. Ultra Rail features two rail profi les; UR-40 is a lightweight rail profi le that is suitable for most geographic regions and maintains all the great features of SnapNrack rail, while UR-60 is a heavier duty rail profi le that provides a larger rail channel and increased span capabilities. Both are compatible with all existing mounts, module clamps, and accessories for ease of install. The Entire System is a Snap to Install • New Ultra Rail Mounts include snap-in brackets for attaching rail • Compatible with all the SnapNrack Mid Clamps and End Clamps customers love • Universal End Clamps and snap-in End Caps provide a clean look to the array edge Heavy Duty UR-60 Rail • UR-60 rail profi le provides increased span capabilities for high wind speeds and snow loads • Taller, stronger rail profi le includes profi le- specifi c rail splice and end cap • All existing mounts, module clamps, and accessories are retained for the same great install experience DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, UR-40 RAIL 232-02449, 232-02450, 232-02451 mwatkins Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANY REPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USA PHONE (415) 580-6900 ● FAX (415) 580-6902B REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM N/A N/A N/A LB-FT UL 2703, FILE E359313 5.85 OPTIONS: CLEAR / BLACK ANODIZED MILL FINISH BUNDLES OF 144 BOXES OF 8 ALL DIMENSIONS IN INCHES UR-40 RAIL PROPERTIES SKU FINISH 232-02449 MILL 232-02450 CLEAR 232-02451 BLACK 1.624 1.500 CENTROID .750 .832 .792 EQUIVALENT PROPERTIES A0.357 in² Ixx 0.125 in⁴ Iyy 0.132 in⁴ Sx (TOP)0.150 in³ Sx (BOT)0.158 in³ Sy (LEFT)0.175 in³ Sy (RIGHT)0.175 in³ Basic Features Stamped Seamless Construction 18 Gauge Galvanized Steel Powder Coated Surfaces Flashes Into the Roof Deck Low Profile - 2.625" Deep 3 Roof Deck Knockouts .5", .75", 1" 5 Centering Dimples for entry/exit of fittings or conduit 2 Position Ground Lug Installed Mounting Hardware Included Roofing Industry Approved Now Available! New SolaDeck UL STD1741 Combiner /Enclosure SolaDeck Model 0783-41 Call for Information 1(866)-367-7782 or simply request more info at sales@commdeck.com WWW. COMMDECK. COM SolaDeck UL50 Type 3R Enclosures All the basic features listed above, ideal for pass through wiring. Transition to house wire is simple, clean and contained in the flashed enclosure. UL50 Type 3R Models: Model 0783 - (3" Fixed Din Rail) Model 0786 - (6" Slotted Din Rail) http://www.readyshare.com/Users/cbateman@rstcenterprises-com/Uplo... 1 of 4 11/18/2009 1:39 PM SolaDeck UL STD 1741 Combiner/ Enclosure Systems Maximum Rating - 600VDC, 120AMPS Frequency DC Models 0783-41 and 0786-41 are ETL listed and labeled to the UL STD 1741 for Photovoltaic Combiner Enclosures. Model 0783-41 Model 0786-41 3" Fixed Din Rail 6" Slotted Din Rail fastened using Norlock System fastened using Steel Studs Typical Wiring Configurations **Fuse holders, terminal blocks and power blocks are sold separately.Fuse holders and terminal blocks added in the field must be UL listed or recognized and meet 600 VDC 30 AMP 110C for fuse holders, 600V 50 AMP 90C for rail mounted terminal blocks and 600 V 175 AMP 90C for power distribution blocks. Use copper wire conductors. SolaDeck Model 0786 ETL Listed UL50 Type 3R Rain tight enclosure for outdoor use Shown: ER 6 Terminal Blocks Transition outdoor wire to THWN wire ER 6 Terminal Blocks used for positive and negative SolaDeck Model 0783-41 ETL listed UL STD 1741 Combiner/Enclosure Shown: with 4 strings with UL Recognized Fuse Holders for PV Positive Power Block for PV Negative Fuses combined with Positive Bus Bar http://www.readyshare.com/Users/cbateman@rstcenterprises-com/Uplo... 2 of 4 11/18/2009 1:39 PM PV negative combined with Power Block SolaDeck Model 0786-41 ETL listed UL STD 1741 Combiner/Enclosure Shown: with 4 strings with UL Recognized Fuse Holders for PV Positive ER 10 Terminal Blocks for PV Negative Fuses combined with Positive Bus Bar ER 10 Terminal Blocks combined using Negative Bus Bar SolaDeck Accessory Parts Now Available 4 String kit for SolaDeck Model 0783-41 (Part# 0783K) Includes: 4 - Midget Fuse Holders Rail Mount (Part# 1452) 1 - Power Block (Part# 1440) 1 - Bus Bar for Fuse Holders (Part# 0784BB) 4 String kit for SolaDeck Model 0786-41 (Part# 0786K) Includes: 4 - Midget Fuse Holders Rail Mount (Part# 1452) 4 - ER 10 Rail Mount Terminal Blocks (Part# 1451) 1 - Bus Bar for Fuse Holders ( Part# 0784BB 1 - Bus Bar for ER 10 Terminal Blocks (Part# 0785BB) 1 - ER 10 End Plate Cover (Part# 1453) http://www.readyshare.com/Users/cbateman@rstcenterprises-com/Uplo... 3 of 4 11/18/2009 1:39 PM Midget Fuse Holders Rail Mount (Part# 1452) Rated to 600V 30 AMPS, Wire # 8-18AWG *Use Part # 0784BB Bus to combine PV Positive Fuses Power Block (Part# 1440) Non Fused Rated to 600V/175 Amps, Main (1) 2/0 - 14, Tap(4) 4-14 Combines up to 4 Strings PV negative Rail Mount Terminal Blocks ER 10 Rail Mount Terminal Block (Part# 1451) Rated to 600V 65 Amps, Wire #16 - 6 AWG, 10mm wide *Use Part# 0785BB Bus to combine strings ER 6 Rail Mount Terminal Block (Part# 1450) Rated to 600V 50 Amps, Wire #26 - 8 AWG, 8mm wide *Use for positive & negative pass through to transition to house wire Bus Bars - Include CA4-SP lug and install Screw Bus Bar (Part# 0784BB) PV Positive Bus - Combine up to 4 midget fuse holders Bus Bar ( Part# 0785BB) PV Negative Bus - Combine up to 4 ER10 terminal blocks RSTC Enterprises, Inc • 2219 Heimstead Road • Eau Claire, WI 54703 • Phone: 715-830-9997 • Fax: 715-830-9976 http://www.readyshare.com/Users/cbateman@rstcenterprises-com/Uplo... 4 of 4 11/18/2009 1:39 PM