HomeMy WebLinkAboutPLANS - 22-00786 - 11 Sunset circle - Solar Panel.pdfWIRING SHALL NOT BE INSTALLED WITHIN 10" OF ROOF DECKING EXCEPT WHEREDIRECTLY BELOW THE ROOF SURFACE COVERED BY PV MODULES AND/OR EQUIPMENTMODULE AND INVERTER(S)PLEASE REFER TO LABEL PLAN FOR WARNINGS PER NEC 690 & IRC 2018SCOPE OF WORKWiring must be properly supported by devices or mechanical meansdesigned and listed for such use. Wiring must be permanently andcompletely held off of the roof surface. NEC 110NOTESNAPCEP HOLDER & CERT #UT. CONTRACTORS LICENSE # & TYPEAPPLICABLE CODESMichael Allen - 032611-4Michael Telford - 092411-142#7426030.5501Class LRF, B100, S200, S2022018 International Building Code (IBC)SHEET INDEXEnphase Micro-Inverters (IQ8A)2017 National Electric Code (NEC)SYSTEM IS "RAPID SHUTDOWN" COMPLIANTREC 410WSTREET VIEWVICINITY MAPTotal Area of Array(s): 576ft²Pass Through Boxes Mounted Flush on Installation Surface (26.5º)System Size: 13.12kWMeter Upgrade: NOStandard Asphalt Shingle RoofArray(s) Azimuth: 270ºAnchored on 48" Centers using UL Listed Snap N Rack UR-40 System2018 International Residential Code (IRC)(32)(32)TITLE SHEETSITE PLANELECTRICAL LINE DIAGRAMEQUIPMENT LABELSARRAY DETAILS (SITE DEPENDENT)INSTALLATION/METER DETAILPV01PV02PV03PV04PV05PV06PV07SITE DIRECTORYSHEET #SCALE:INTERMOUNTAIN WIND & SOLAR 1041 N 950 W SUITE 500 CENTERVILLE, UT 84014 P: 801-298-5255 F: 801-298-5355 PROJECT # SYSTEM SIZE: AHJ: DATE: 2022-742-ID 13.12kW - (32) Modules Rexburg 10/12/2022 Designer Revision Kelly Merrill 11 West Sunset Circle, Rexburg, Idaho 83440 J.TooneMichael Telford - 092411-142PV01N.T.S 9012015018021024027030033003060WESN8070504O2010350320310290280260250230220200190170160140130110100340AZIMUTHLEGENDPV/AC DISCONNECTSUB PANELSBAC LOAD PANELLPUTILITY METER MAIN MROOFTOP JUNCTION BOX36"/18" FIRE CODECLEARANCEPRODUCTION METER PIQ COMBINERACPV MODULETRENCHING (1) 2" SCH. 40,(1) 1" SCH. 40 PV @ 2' DEPTHPROPERTY LINE*GROUND MOUNTED SYSTEMS SHALLMAINTAIN MINIMUM 10' SETBACK FROMPROP. LINESPV BRANCH CIRCUIT CBALLASTED RACKINGENERGY STORAGE SYSTEM ESSESS PUSH-BUTTON DISCONNECTBDIQ CONTROLLER IQPASS THROUGH BREAKER PTBBACKUP GATEWAY BGGENERATION PANEL GPRAPID SHUTDOWN DEVICEWIRING SHALL NOT BE INSTALLED WITHIN 10" OF ROOF DECKING EXCEPT WHEREDIRECTLY BELOW THE ROOF SURFACE COVERED BY PV MODULES AND/OR EQUIPMENTMODULE AND INVERTER(S)PLEASE REFER TO LABEL PLAN FOR WARNINGS PER NEC 690 & IRC 2018SCOPE OF WORKWiring must be properly supported by devices or mechanical meansdesigned and listed for such use. Wiring must be permanently andcompletely held off of the roof surface. NEC 110NOTESEnphase Micro-Inverters (IQ8A)SYSTEM IS "RAPID SHUTDOWN" COMPLIANTREC 410WTotal Area of Array(s): 576ft²Pass Through Boxes Mounted Flush on Installation Surface (26.5º)System Size: 13.12kWMeter Upgrade: NOStandard Asphalt Shingle RoofArray(s) Azimuth: 270ºAnchored on 48" Centers using UL Listed Snap N Rack UR-40 System(32)(32) MLPAC CSHEET #SCALE:INTERMOUNTAIN WIND & SOLAR 1041 N 950 W SUITE 500 CENTERVILLE, UT 84014 P: 801-298-5255 F: 801-298-5355 PROJECT # SYSTEM SIZE: AHJ: DATE: 2022-742-ID 13.12kW - (32) Modules Rexburg 10/12/2022 Designer Revision Kelly Merrill 11 West Sunset Circle, Rexburg, Idaho 83440 J.TooneMichael Telford - 092411-142PV02116" = 1' TYPICAL SOLAR PANELSCONNECTED TO MICROINVERTERSJ-BOXNEMA 4J-BOX6"x6"x3"60A 120/240VFUSED DISCONNECT(2) 60A Fuses80A ENPHASE IQ COMBINER 3EXISTINGMETER MAIN200A 240 / 120TO GRIDGL1L2L1L2BI-DIRECTIONALUTILITY METERNHome AC Load Center200A 240 / 120MCB200A - 2PNL1L2G(1)3/ 4" EMT(3)#6THWN-2(1)#10THWN-2 EG20A - 2P20A - 2P20A - 2PFACTORY INSTALLED2P MONITORING BREAKER(15A or 10A)EXISTING(1) 2" EMT(3)#4/0THWN-2 AL(1)#6THWN-2 EG(1)3/ 4" EMT(3)#6THWN-2(1)#10THWN-2 EG(1)3/ 4" EMT(6)#10THWN-2(1)#10THWN-2 EGINTERCONNECTION PCC MADE IN EXISTING INTERIOR 240VAC, 200AAC 1 PHASEHOME LOAD PANEL WITH SUPPLY SIDE FEEDERS. TAP WILLUSE INSULATED PIERCING CONNECTER (NSI INDUSTRIES)WITH 60AAC FUSED DISCONNECT WITH 60A FUSES AS OCPD.THIS CONNECTION SHALL BE MADE IN CONFORMANCE WITH2017 NEC 705.12.46.4A240VPHOTOVOLTAIC AC OUTPUT LABELAC OUTPUT CURRENTNOMINAL AC VOLTAGEELECTRICAL NOTES: 1. ALL COMPONENTS ARE GROUNDED PER NEC 2017 CODE 2. INTERCONNECTION METHOD COMPLIES WITH NEC 690 3. ALL WIRES WILL BE RATED THHN/THWN-2 4. ALL INTERCONNECTION WILL COMPLY WITH NEC 705.12RAPID SHUTDOWN SWITCH FOR PV SYSTEMPLEASE REFER TO PV06 FORREFERENCE PHOTOS* ACTUAL AC/DC WIRING AND/OR CONDUIT BODY TO BE DETERMINED IN FIELD. MAY BE REPLACED BYNMB/MC CABLE.INVERTER SPECIFICATIONSMANUFACTUREREnphase EnergyMODELIQ8A-72-2-USMAX DC INPUT VOLTAGE60 VMAX OUTPUT POWER349 WNOMINAL AC OUTPUT VOLTAGE240 VNOMINAL AC OUTPUT CURRENT1.45 AMAX FUSE (OCPD)20 APV MODULE SPECIFICATIONSMANUFACTURERRECMODEL410WMAX POWER-POINT CURRENT (Imp)9.61 AMAX POWER-POINT VOLTAGE (Vmp)42.7 VOPEN CIRCUIT VOLTAGE (Voc)49 VSHORT CIRCUIT CURRENT (Isc)10.35 AMAX SERIES FUSE (OCPD)25 AMAX POWER (Pmax)410 WMAX VOLTAGE (Vdc)1000 V* ARRAY COMPLIES WITH 2017 NEC 690.12INDOOR/OUTDOORTRANSITION/PULL BOXLOCATION TBD IN FIELDDISCONNECT(S) TO BEGROUPED WITHIN 3' FEETOF METER MAINFREE AIR(3) ENPHASE Q - CABLE(1)#6 BARE COPPER EG(1) 3/ 4" EMT(6)#10THWN-2(1)#10THWN-2 EG10111011910SHEET #SCALE:INTERMOUNTAIN WIND & SOLAR 1041 N 950 W SUITE 500 CENTERVILLE, UT 84014 P: 801-298-5255 F: 801-298-5355 PROJECT # SYSTEM SIZE: AHJ: DATE: 2022-742-ID 13.12kW - (32) Modules Rexburg 10/12/2022 Designer Revision Kelly Merrill 11 West Sunset Circle, Rexburg, Idaho 83440 J.TooneMichael Telford - 092411-142PV03N.T.S MICRO INVERTER SYSTEM SIGNAGE*All signage must be permanently attached and be able to withstand the environmentthey are installed. Signage also cannot be hand-written. NEC 110.A sign is required at the service panelstating that the home has a solar PVsystem as an additionalpower source.This sign is required to be located next tothe PV backfed breaker(s) ONLY if the120% allowance ofNEC 705.12PV SYSTEM:AC Current = 46.4AAC Volts = 240VThis sign is required to be located at theback-fed panelboard.This sign is required to be located at thebackfed panelboard.SOLAR METERPARALLEL GENERATIONON SITE*PLACARD REQUIRED BY UTILITY*PLACARD REQUIRED BY UTILITYMANUAL DISCONNECTFORPARALLEL GENERATIONWITHIN 10' OFMETER WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM WARNINGPOWER SOURCE OUTPUT CONNECTION, DO NOTRELOCATE THIS OVERCURRENT DEVICE. WARNINGThis sign to be located on the outside of,and within 3’ ofthe service equipment.RAPID SHUTDOWNSWITCH FOR SOLARPV SYSTEMMust be provided next to the rapidshutdown disconnect forthis system.*IF ESS SYSTEM PRESENTREMOVE THIS LABELELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE AND LOADSIDES MAY BE ENERGIZED IN THEOPEN POSITIONPV SYSTEM DISCONNECTMust be provided on distrubutionequipment NEC 705.12 (B) (3) (3)SHEET #SCALE:INTERMOUNTAIN WIND & SOLAR 1041 N 950 W SUITE 500 CENTERVILLE, UT 84014 P: 801-298-5255 F: 801-298-5355 PROJECT # SYSTEM SIZE: AHJ: DATE: 2022-742-ID 13.12kW - (32) Modules Rexburg 10/12/2022 Designer Revision Kelly Merrill 11 West Sunset Circle, Rexburg, Idaho 83440 J.TooneMichael Telford - 092411-142PV05N.T.S METER WALLEXISTING SITE PHOTOSLOAD PANEL DETAILATTIC DETAILSHEET #SCALE:INTERMOUNTAIN WIND & SOLAR 1041 N 950 W SUITE 500 CENTERVILLE, UT 84014 P: 801-298-5255 F: 801-298-5355 PROJECT # SYSTEM SIZE: AHJ: DATE: 2022-742-ID 13.12kW - (32) Modules Rexburg 10/12/2022 Designer Revision Kelly Merrill 11 West Sunset Circle, Rexburg, Idaho 83440 J.TooneMichael Telford - 092411-142PV06N.T.S NCAUTION: MULTIPLE SOURCES OF POWERPERMANENT PLAQUE OR DIRECTORYINSTALLED AT EACH SERVICEEQUIPMENT LOCATION NEC 705.10PVHOUSEUTILITY METERMANUAL DISCONNECT FORSOLAR GENERATIONSHEET #SCALE:INTERMOUNTAIN WIND & SOLAR 1041 N 950 W SUITE 500 CENTERVILLE, UT 84014 P: 801-298-5255 F: 801-298-5355 PROJECT # SYSTEM SIZE: AHJ: DATE: 2022-742-ID 13.12kW - (32) Modules Rexburg 10/12/2022 Designer Revision Kelly Merrill 11 West Sunset Circle, Rexburg, Idaho 83440 J.TooneMichael Telford - 092411-142PV06N.T.S