Loading...
HomeMy WebLinkAboutAPPROVED PLANS 2 - 21-00717 - Metal Office Building Vet ClinicAuthor Name Author Email Author Phone No.: Stan Crittenden Stan.Crittenden@rexburg.org 208-372-2314 Cody Jones Cody.Jones@rexburg.org 208-372-2173 Description : Metal Office Building Vet Clinic Address : Record Type : Madison County - Commercial Document Filename : IRON MAN VET CLINIC PDF 2.0 - final.pdf Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Approved # 21-00717 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments G-101 Free text Cody Jones : Building Open 1 Will need insulation certificate once insulation installed. G-101 Free text Cody Jones : Building Open 1 Will need special inspection results. G-101 Free text Cody Jones : Building Open 1 Risk category: 2 G-101 Stamp Cody Jones : Building Open 1 Approved - Building Inspector G-104 Free text Cody Jones : Building Open 4 Seating at tables, counters, and work areas need to comply with section 1109.11 S-101 Free text Cody Jones : Building Open 8 Finished grade to slope 6" in first 10'. S-201 Free text Cody Jones : Building Open 9 Floor joist and cantilever joist to meet manufacturer specifications. S-301 Line Cody Jones : Building Open 10 S-301 Free text Cody Jones : Building Open 10 7" max S-301 Line Cody Jones : Building Open 10 S-301 Free text Cody Jones : Building Open 10 11" min Madison County - Commercial Approval of plans does not constitute approval of variance from code Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments S-301 Free text Cody Jones : Building Open 10 All wood in contact with concrete needs to be pressure treated. S-301 Free text Cody Jones : Building Open 10 Handrails and guards need to meet the requirements of IBC section 1014 and 1015. S-301 Free text Cody Jones : Building Open 10 Stairs to be protected as per section 1023. E-101 Free text Cody Jones : Building Open 12 Exit lighting and Exit signs comply with IBC section 1008 and 1013. G-101 Stamp Stan Crittenden : Fire Open 1 Approved - Fire Dept Approval of plans does not constitute approval of variance from code Powered by TCPDF (www.tcpdf.org) DE S C R I P T I O N RE V I S I O N D A T E CO V E R S H E E T SH E E T T I T L E : G-101 PLN# 21-10-031 DR A W N B Y : CH K ' D B Y : D. M . #1 - 5 C h e c k e d B y PL O T D A T E : 1/ 1 3 / 2 0 2 2 EN G I N E E R : R A Y M C D O U G A L , P E EI T : # 1 - 4 E N G I N E E R I N T E R N 1/13/2022 12 7 E . M a i n S t . S u i t e 1 1 1 Re x b u r g , I D 8 3 4 4 0 ww w . s o u t h f o r k d e s i g n . c o m 20 8 - 8 5 2 - 6 2 3 6 So u t h F o r k D e s i g n G r o u p , L L C VE T C L I N I C #1 - 1 C L I E N T A D D R E S S #1 - 2 C L I E N T A D D R E S S THESE PLANS ARE STAMPED/ENGINEERED FOR THE LOCATION SPECIFIED. IF LOCATION CHANGES REENGINEERING IS REQUIRED. Co p y r i g h t 2 0 2 2 | S o u t h f o r k E n g i n e e r i n g | A l l R i g h t s R e s e r v e d . INDEX OF SHEETS G-101 G-102 G-103 G-104 A-101 A-102 A-301 S-101 S-201 S-301 S-302 E-101 COVER SHEET EGRESS/FIRE MAIN LEVEL EGRESS/FIRE 2ND LEVEL ADA clearances MAIN LEVEL SECOND LEVEL SECTIONS FOUNDATION 2ND FLOOR FRAMING MAIN L. WALL FRAMING 2ND L. WALL FRAMING MEP MARKUP PLAN FINISHED SQUARE FOOTAGEFINISHED SQUARE FOOTAGEFINISHED SQUARE FOOTAGEFINISHED SQUARE FOOTAGE ID SECOND FLOOR OFFICE WAREHOUSE MERCH. AREA 2,036 2,015 1,500 1,485 7,036 ft² LOCATION: MADISON ROOF SNOW: 50 PSF GROUND SNOW: 36 PSF WIND SPEED: 115 MPH EXPOSURE: C FROST DEPTH: 36 INCHES SEISMIC: D Ss .504 S1 .172 SDS .469 SD1 .259 REGULATION: IBC 2018 VET CLINICVET CLINICVET CLINICVET CLINIC ENERGY COMPLIANCEENERGY COMPLIANCEENERGY COMPLIANCEENERGY COMPLIANCE PRESCRIPTIVE METHOD:PRESCRIPTIVE METHOD:PRESCRIPTIVE METHOD:PRESCRIPTIVE METHOD: CLIMATE ZONE 6CLIMATE ZONE 6CLIMATE ZONE 6CLIMATE ZONE 6 MIN R22 IN WALLSMIN R22 IN WALLSMIN R22 IN WALLSMIN R22 IN WALLS MIN R30 IN FLOORMIN R30 IN FLOORMIN R30 IN FLOORMIN R30 IN FLOOR MIN R49 IN ATTICMIN R49 IN ATTICMIN R49 IN ATTICMIN R49 IN ATTIC MIN R15/19 CRAWL SPACE WALLSMIN R15/19 CRAWL SPACE WALLSMIN R15/19 CRAWL SPACE WALLSMIN R15/19 CRAWL SPACE WALLS MIN .30 WINDOW U-FACTORMIN .30 WINDOW U-FACTORMIN .30 WINDOW U-FACTORMIN .30 WINDOW U-FACTOR MIN .30 DOOR U-FACTORMIN .30 DOOR U-FACTORMIN .30 DOOR U-FACTORMIN .30 DOOR U-FACTOR Will need insulation certificate once insulation installed. Will need special inspection results. Risk category: 2 DE S C R I P T I O N RE V I S I O N D A T E EG R E S S / F I R E M A I N L E V E L SH E E T T I T L E : G-102 PLN# 21-10-031 DR A W N B Y : CH K ' D B Y : D. M . #1 - 5 C h e c k e d B y PL O T D A T E : 1/ 1 3 / 2 0 2 2 EN G I N E E R : R A Y M C D O U G A L , P E EI T : # 1 - 4 E N G I N E E R I N T E R N 1/13/2022 12 7 E . M a i n S t . S u i t e 1 1 1 Re x b u r g , I D 8 3 4 4 0 ww w . s o u t h f o r k d e s i g n . c o m 20 8 - 8 5 2 - 6 2 3 6 So u t h F o r k D e s i g n G r o u p , L L C VE T C L I N I C #1 - 1 C L I E N T A D D R E S S #1 - 2 C L I E N T A D D R E S S THESE PLANS ARE STAMPED/ENGINEERED FOR THE LOCATION SPECIFIED. IF LOCATION CHANGES REENGINEERING IS REQUIRED. Co p y r i g h t 2 0 2 2 | S o u t h f o r k E n g i n e e r i n g | A l l R i g h t s R e s e r v e d . UP W DR F. E . F. E . 1,561 sq ft1,561 sq ft1,561 sq ft1,561 sq ft 1 A-301 1 A-301 1,507 sq ft1,507 sq ft1,507 sq ft1,507 sq ft EXTERIOR WALLS ANDEXTERIOR WALLS ANDEXTERIOR WALLS ANDEXTERIOR WALLS AND ROOF STRUCTURE ROOF STRUCTURE ROOF STRUCTURE ROOF STRUCTURE BYBYBYBY STEEL MANUFACTURERSTEEL MANUFACTURERSTEEL MANUFACTURERSTEEL MANUFACTURER OFFICEOFFICEOFFICEOFFICEOFFICEOFFICEOFFICEOFFICE//// STORAGESTORAGESTORAGESTORAGE OFFICEOFFICEOFFICEOFFICE/CONFERENCE/CONFERENCE/CONFERENCE/CONFERENCE ROOMROOMROOMROOM OL: OL: OL: OL: 6666 OL: OL: OL: OL: 4444 E X I T E X I T E X I T E X I T E X I T E X I T E X I T E X I T EXITEXITEXITEXIT 707 sq ft707 sq ft707 sq ft707 sq ft 1,224 sq ft1,224 sq ft1,224 sq ft1,224 sq ft STORAGESTORAGESTORAGESTORAGE COOLERCOOLERCOOLERCOOLER BREEZEWAYBREEZEWAYBREEZEWAYBREEZEWAY EMPLOYEE BATHEMPLOYEE BATHEMPLOYEE BATHEMPLOYEE BATH OL: 5OL: 5OL: 5OL: 5 UTILITYUTILITYUTILITYUTILITY CUSTOMERCUSTOMERCUSTOMERCUSTOMER BATHBATHBATHBATH OL: 5OL: 5OL: 5OL: 5 EXIT COMMON TRAVELEXIT COMMON TRAVELEXIT COMMON TRAVELEXIT COMMON TRAVEL PATH DISTANCE: PATH DISTANCE: PATH DISTANCE: PATH DISTANCE: 24242424'''' EXIT EXIT EXIT EXIT TOTAL TRAVELTOTAL TRAVELTOTAL TRAVELTOTAL TRAVEL PATH DISTANCEPATH DISTANCEPATH DISTANCEPATH DISTANCE: 75': 75': 75': 75' E X I T A C C E S S T R A V E L E X I T A C C E S S T R A V E L E X I T A C C E S S T R A V E L E X I T A C C E S S T R A V E L D I S T A N C E : D I S T A N C E : D I S T A N C E : D I S T A N C E : 4 04 0 4 04 0 '''' E X I T T O T A L T R A V E L E X I T T O T A L T R A V E L E X I T T O T A L T R A V E L E X I T T O T A L T R A V E L P A T H D I S T A N C E : P A T H D I S T A N C E : P A T H D I S T A N C E : P A T H D I S T A N C E : 5 3 5 3 5 3 5 3 '''' E X I T C O M M O N T R A V E L E X I T C O M M O N T R A V E L E X I T C O M M O N T R A V E L E X I T C O M M O N T R A V E L P A T H D I S T A N C E : 2 P A T H D I S T A N C E : 2 P A T H D I S T A N C E : 2 P A T H D I S T A N C E : 2 3 3 3 3 '''' EXIT COMMON EXIT COMMON EXIT COMMON EXIT COMMON TRAVEL PATH TRAVEL PATH TRAVEL PATH TRAVEL PATH DISTANCE: DISTANCE: DISTANCE: DISTANCE: 8888'''' 1 EGRESS/FIRE MAIN STORYEGRESS/FIRE MAIN STORYEGRESS/FIRE MAIN STORYEGRESS/FIRE MAIN STORY SCALE: SCALE: SCALE: SCALE: 1/4" = 1'-0"1/4" = 1'-0"1/4" = 1'-0"1/4" = 1'-0" CODE SUMMARYCODE SUMMARYCODE SUMMARYCODE SUMMARY CONSTRUCTION TYPE: VB UNSPRINKLEREDCONSTRUCTION TYPE: VB UNSPRINKLEREDCONSTRUCTION TYPE: VB UNSPRINKLEREDCONSTRUCTION TYPE: VB UNSPRINKLERED 7048 SQ FT7048 SQ FT7048 SQ FT7048 SQ FT OCCUPANCY: BOCCUPANCY: BOCCUPANCY: BOCCUPANCY: B OLF:OLF:OLF:OLF: ACCESSORYACCESSORYACCESSORYACCESSORY////MECHANICAL MECHANICAL MECHANICAL MECHANICAL 1/3001/3001/3001/300 GROSS GROSS GROSS GROSS MERCHANTILE AND STORAGE MERCHANTILE AND STORAGE MERCHANTILE AND STORAGE MERCHANTILE AND STORAGE 1/3001/3001/3001/300 GROSS GROSS GROSS GROSS WAREHOUSE WAREHOUSE WAREHOUSE WAREHOUSE 1/5001/5001/5001/500 GROSS GROSS GROSS GROSS OFFICE AND BUSINESS AREAS OFFICE AND BUSINESS AREAS OFFICE AND BUSINESS AREAS OFFICE AND BUSINESS AREAS 1/1501/1501/1501/150 GROSS GROSS GROSS GROSS CONFERENCE ROOM CONFERENCE ROOM CONFERENCE ROOM CONFERENCE ROOM 1/501/501/501/50 GROSS GROSS GROSS GROSS TOTAL OCCUPANT LOAD: TOTAL OCCUPANT LOAD: TOTAL OCCUPANT LOAD: TOTAL OCCUPANT LOAD: 39393939 NUMBER EXITS: 3NUMBER EXITS: 3NUMBER EXITS: 3NUMBER EXITS: 3 MAX. ALOWABLE EXIT ACCESS DISTANCE: 200'MAX. ALOWABLE EXIT ACCESS DISTANCE: 200'MAX. ALOWABLE EXIT ACCESS DISTANCE: 200'MAX. ALOWABLE EXIT ACCESS DISTANCE: 200' MAXMAXMAXMAX. . . . COMMON PATH OF EGRESS TRAVEL COMMON PATH OF EGRESS TRAVEL COMMON PATH OF EGRESS TRAVEL COMMON PATH OF EGRESS TRAVEL ((((OLOLOLOL≥≥≥≥30303030): ): ): ): 75757575'''' FIXTURES REQUIRED:FIXTURES REQUIRED:FIXTURES REQUIRED:FIXTURES REQUIRED: WATER CLOSET 1/25 FOR THE FIRST 50WATER CLOSET 1/25 FOR THE FIRST 50WATER CLOSET 1/25 FOR THE FIRST 50WATER CLOSET 1/25 FOR THE FIRST 50 LAV COUNT 1/40 FOR THE FIRST 80LAV COUNT 1/40 FOR THE FIRST 80LAV COUNT 1/40 FOR THE FIRST 80LAV COUNT 1/40 FOR THE FIRST 80 DRINKING FOUNTAIN 1/100DRINKING FOUNTAIN 1/100DRINKING FOUNTAIN 1/100DRINKING FOUNTAIN 1/100 DE S C R I P T I O N RE V I S I O N D A T E EG R E S S / F I R E 2 N D L E V E L SH E E T T I T L E : G-103 PLN# 21-10-031 DR A W N B Y : CH K ' D B Y : D. M . #1 - 5 C h e c k e d B y PL O T D A T E : 1/ 1 3 / 2 0 2 2 EN G I N E E R : R A Y M C D O U G A L , P E EI T : # 1 - 4 E N G I N E E R I N T E R N 1/13/2022 12 7 E . M a i n S t . S u i t e 1 1 1 Re x b u r g , I D 8 3 4 4 0 ww w . s o u t h f o r k d e s i g n . c o m 20 8 - 8 5 2 - 6 2 3 6 So u t h F o r k D e s i g n G r o u p , L L C VE T C L I N I C #1 - 1 C L I E N T A D D R E S S #1 - 2 C L I E N T A D D R E S S THESE PLANS ARE STAMPED/ENGINEERED FOR THE LOCATION SPECIFIED. IF LOCATION CHANGES REENGINEERING IS REQUIRED. Co p y r i g h t 2 0 2 2 | S o u t h f o r k E n g i n e e r i n g | A l l R i g h t s R e s e r v e d . DOWN F. E . 1 A-301 1 A-301 416 sq ft416 sq ft416 sq ft416 sq ft 444 sq ft444 sq ft444 sq ft444 sq ft 1,101 sq ft1,101 sq ft1,101 sq ft1,101 sq ft EXTERIOR WALLS ANDEXTERIOR WALLS ANDEXTERIOR WALLS ANDEXTERIOR WALLS AND ROOF STRUCTURE ROOF STRUCTURE ROOF STRUCTURE ROOF STRUCTURE BYBYBYBY STEEL MANUFACTURERSTEEL MANUFACTURERSTEEL MANUFACTURERSTEEL MANUFACTURER OWNER'S OWNER'S OWNER'S OWNER'S OFFICEOFFICEOFFICEOFFICE BATHROOMBATHROOMBATHROOMBATHROOM OWNER'S FLEX ROOMOWNER'S FLEX ROOMOWNER'S FLEX ROOMOWNER'S FLEX ROOMSTORAGESTORAGESTORAGESTORAGE OWNER'S OWNER'S OWNER'S OWNER'S OFFICEOFFICEOFFICEOFFICE CONFERENCECONFERENCECONFERENCECONFERENCE OL: 2OL: 2OL: 2OL: 2 OL: 8OL: 8OL: 8OL: 8 OL: OL: OL: OL: 9999 E X I T E X I T E X I T E X I T EXITEXITEXITEXIT EXIT TOTAL TRAVELEXIT TOTAL TRAVELEXIT TOTAL TRAVELEXIT TOTAL TRAVEL PATH DISTANCE: PATH DISTANCE: PATH DISTANCE: PATH DISTANCE: 94949494'''' EXIT TOTAL TRAVELEXIT TOTAL TRAVELEXIT TOTAL TRAVELEXIT TOTAL TRAVEL PATH DISTANCE: 10PATH DISTANCE: 10PATH DISTANCE: 10PATH DISTANCE: 104444'''' EXIT COMMON TRAVELEXIT COMMON TRAVELEXIT COMMON TRAVELEXIT COMMON TRAVEL PATH DISTANCE: PATH DISTANCE: PATH DISTANCE: PATH DISTANCE: 67676767'''' EXIT COMMON TRAVELEXIT COMMON TRAVELEXIT COMMON TRAVELEXIT COMMON TRAVEL PATH DISTANCE: PATH DISTANCE: PATH DISTANCE: PATH DISTANCE: 72727272'''' E X I T C O M M O N T R A V E L E X I T C O M M O N T R A V E L E X I T C O M M O N T R A V E L E X I T C O M M O N T R A V E L P A T H D I S T A N C E : P A T H D I S T A N C E : P A T H D I S T A N C E : P A T H D I S T A N C E : 4 54 54 54 5 '''' 1 EGRESS/FIRE 2ND FLOOREGRESS/FIRE 2ND FLOOREGRESS/FIRE 2ND FLOOREGRESS/FIRE 2ND FLOOR SCALE: SCALE: SCALE: SCALE: 1/4" = 1'-0"1/4" = 1'-0"1/4" = 1'-0"1/4" = 1'-0" CODE SUMMARYCODE SUMMARYCODE SUMMARYCODE SUMMARY CONSTRUCTION TYPE: VB UNSPRINKLEREDCONSTRUCTION TYPE: VB UNSPRINKLEREDCONSTRUCTION TYPE: VB UNSPRINKLEREDCONSTRUCTION TYPE: VB UNSPRINKLERED 7048 SQ FT7048 SQ FT7048 SQ FT7048 SQ FT OCCUPANCY: BOCCUPANCY: BOCCUPANCY: BOCCUPANCY: B OLF:OLF:OLF:OLF: ACCESSORYACCESSORYACCESSORYACCESSORY////MECHANICAL MECHANICAL MECHANICAL MECHANICAL 1/3001/3001/3001/300 GROSS GROSS GROSS GROSS MERCHANTILE AND STORAGE MERCHANTILE AND STORAGE MERCHANTILE AND STORAGE MERCHANTILE AND STORAGE 1/3001/3001/3001/300 GROSS GROSS GROSS GROSS WAREHOUSE WAREHOUSE WAREHOUSE WAREHOUSE 1/5001/5001/5001/500 GROSS GROSS GROSS GROSS OFFICE AND BUSINESS AREAS OFFICE AND BUSINESS AREAS OFFICE AND BUSINESS AREAS OFFICE AND BUSINESS AREAS 1/1501/1501/1501/150 GROSS GROSS GROSS GROSS CONFERENCE ROOM CONFERENCE ROOM CONFERENCE ROOM CONFERENCE ROOM 1/501/501/501/50 GROSS GROSS GROSS GROSS TOTAL OCCUPANT LOAD: TOTAL OCCUPANT LOAD: TOTAL OCCUPANT LOAD: TOTAL OCCUPANT LOAD: 39393939 NUMBER EXITS: 3NUMBER EXITS: 3NUMBER EXITS: 3NUMBER EXITS: 3 MAX. ALOWABLE EXIT ACCESS DISTANCE: 200'MAX. ALOWABLE EXIT ACCESS DISTANCE: 200'MAX. ALOWABLE EXIT ACCESS DISTANCE: 200'MAX. ALOWABLE EXIT ACCESS DISTANCE: 200' MAXMAXMAXMAX. . . . COMMON PATH OF EGRESS TRAVEL COMMON PATH OF EGRESS TRAVEL COMMON PATH OF EGRESS TRAVEL COMMON PATH OF EGRESS TRAVEL ((((OLOLOLOL≥≥≥≥30303030): ): ): ): 75757575'''' FIXTURES REQUIRED:FIXTURES REQUIRED:FIXTURES REQUIRED:FIXTURES REQUIRED: WATER CLOSET 1/25 FOR THE FIRST 50WATER CLOSET 1/25 FOR THE FIRST 50WATER CLOSET 1/25 FOR THE FIRST 50WATER CLOSET 1/25 FOR THE FIRST 50 LAV COUNT 1/40 FOR THE FIRST 80LAV COUNT 1/40 FOR THE FIRST 80LAV COUNT 1/40 FOR THE FIRST 80LAV COUNT 1/40 FOR THE FIRST 80 DRINKING FOUNTAIN 1/100DRINKING FOUNTAIN 1/100DRINKING FOUNTAIN 1/100DRINKING FOUNTAIN 1/100 DE S C R I P T I O N RE V I S I O N D A T E AD A c l e a r a n c e s SH E E T T I T L E : G-104 PLN# 21-10-031 DR A W N B Y : CH K ' D B Y : D. M . #1 - 5 C h e c k e d B y PL O T D A T E : 1/ 1 3 / 2 0 2 2 EN G I N E E R : R A Y M C D O U G A L , P E EI T : # 1 - 4 E N G I N E E R I N T E R N 1/13/2022 12 7 E . M a i n S t . S u i t e 1 1 1 Re x b u r g , I D 8 3 4 4 0 ww w . s o u t h f o r k d e s i g n . c o m 20 8 - 8 5 2 - 6 2 3 6 So u t h F o r k D e s i g n G r o u p , L L C VE T C L I N I C #1 - 1 C L I E N T A D D R E S S #1 - 2 C L I E N T A D D R E S S THESE PLANS ARE STAMPED/ENGINEERED FOR THE LOCATION SPECIFIED. IF LOCATION CHANGES REENGINEERING IS REQUIRED. Co p y r i g h t 2 0 2 2 | S o u t h f o r k E n g i n e e r i n g | A l l R i g h t s R e s e r v e d . UP W DR 2 A- 3 0 1 1 A-301 1 A-301 EXTERIOR WALLS ANDEXTERIOR WALLS ANDEXTERIOR WALLS ANDEXTERIOR WALLS AND ROOF STRUCTURE ROOF STRUCTURE ROOF STRUCTURE ROOF STRUCTURE BYBYBYBY STEEL MANUFACTURERSTEEL MANUFACTURERSTEEL MANUFACTURERSTEEL MANUFACTURER SERVICE SINK ASSERVICE SINK ASSERVICE SINK ASSERVICE SINK AS REQUIRED PERREQUIRED PERREQUIRED PERREQUIRED PER [P] 2902.1[P] 2902.1[P] 2902.1[P] 2902.1 FRONTFRONTFRONTFRONT PUSHPUSHPUSHPUSH FR O N T FR O N T FR O N T FR O N T PU S H PU S H PU S H PU S H FRONTFRONTFRONTFRONT PUSHPUSHPUSHPUSH FRONTFRONTFRONTFRONT PUSHPUSHPUSHPUSH FR O N T FR O N T FR O N T FR O N T PU S H PU S H PU S H PU S H FR O N T FR O N T FR O N T FR O N T PU S H PU S H PU S H PU S H FRONTFRONTFRONTFRONT PUSHPUSHPUSHPUSH FR O N T FR O N T FR O N T FR O N T PU L L PU L L PU L L PU L L 18 " 18 " 18 " 18 " FRONTFRONTFRONTFRONT PULLPULLPULLPULL 18"18"18"18" FRONTFRONTFRONTFRONT PULLPULLPULLPULL 18"18"18"18" FRONTFRONTFRONTFRONT PULLPULLPULLPULL 18"18"18"18" OFFICEOFFICEOFFICEOFFICEOFFICEOFFICEOFFICEOFFICE//// STORAGESTORAGESTORAGESTORAGE OFFICEOFFICEOFFICEOFFICE/CONFERENCE/CONFERENCE/CONFERENCE/CONFERENCE ROOMROOMROOMROOM BREEZEWAYBREEZEWAYBREEZEWAYBREEZEWAY EMPLOYEE BATHEMPLOYEE BATHEMPLOYEE BATHEMPLOYEE BATH CUSTOMERCUSTOMERCUSTOMERCUSTOMER BATHBATHBATHBATH FRONTFRONTFRONTFRONT PULLPULLPULLPULL 18"18"18"18" FR O N T FR O N T FR O N T FR O N T PU L L PU L L PU L L PU L L 18 " 18 " 18 " 18 " FRONTFRONTFRONTFRONT PULLPULLPULLPULL 18"18"18"18" FRONTFRONTFRONTFRONT PULLPULLPULLPULL 18"18"18"18" 60"60"60"60" 56565656XXXX60606060 56565656XXXX60606060 30 X 4 8 30 X 4 8 30 X 4 8 30 X 4 8 60"60"60"60" 30 X 4 8 30 X 4 8 30 X 4 8 30 X 4 8 FRONTFRONTFRONTFRONT PUSHPUSHPUSHPUSH FRONTFRONTFRONTFRONT PULLPULLPULLPULL 18"18"18"18" FRONTFRONTFRONTFRONT PULLPULLPULLPULL 18"18"18"18" FRONTFRONTFRONTFRONT PUSHPUSHPUSHPUSH FRONTFRONTFRONTFRONT PUSHPUSHPUSHPUSH FRONTFRONTFRONTFRONT PUSHPUSHPUSHPUSH FR O N T FR O N T FR O N T FR O N T PU L L PU L L PU L L PU L L 18 " 18 " 18 " 18 " FR O N T FR O N T FR O N T FR O N T PU L L PU L L PU L L PU L L 18 " 18 " 18 " 18 " FR O N T FR O N T FR O N T FR O N T PU L L PU L L PU L L PU L L 18 " 18 " 18 " 18 " FR O N T FR O N T FR O N T FR O N T PU S H PU S H PU S H PU S H FR O N T FR O N T FR O N T FR O N T PU S H PU S H PU S H PU S H FRONTFRONTFRONTFRONT PULLPULLPULLPULL FRONTFRONTFRONTFRONT PUSHPUSHPUSHPUSH 30 X 4 8 30 X 4 8 30 X 4 8 30 X 4 8 STORAGESTORAGESTORAGESTORAGE COOLERCOOLERCOOLERCOOLER UTILITYUTILITYUTILITYUTILITY 9"9"9"9" MI N MI N MI N MI N 17" MIN17" MIN17" MIN17" MIN 25" MAX25" MAX25" MAX25" MAX 6"6"6"6" MAXMAXMAXMAX 11"11"11"11" MINMINMINMIN 8"8"8"8" MINMINMINMIN 27 " 27 " 27 " 27 " MI N MI N MI N MI N 34 " 34 " 34 " 34 " MA X MA X MA X MA X ADA HANDLEADA HANDLEADA HANDLEADA HANDLE MIRRORMIRRORMIRRORMIRROR BASIN HEIGHTBASIN HEIGHTBASIN HEIGHTBASIN HEIGHT KNEE CLEARANCEKNEE CLEARANCEKNEE CLEARANCEKNEE CLEARANCE INSULATE EXPOSED PIPESINSULATE EXPOSED PIPESINSULATE EXPOSED PIPESINSULATE EXPOSED PIPES 15 " M I N 15 " M I N 15 " M I N 15 " M I N 48 " M A X 48 " M A X 48 " M A X 48 " M A X 40 " 40 " 40 " 40 " MA X T O R E F L E C T I V E MA X T O R E F L E C T I V E MA X T O R E F L E C T I V E MA X T O R E F L E C T I V E SU R F A C E SU R F A C E SU R F A C E SU R F A C E 2'-6"2'-6"2'-6"2'-6" MIN. CLR. WIDTHMIN. CLR. WIDTHMIN. CLR. WIDTHMIN. CLR. WIDTH MIRRORMIRRORMIRRORMIRROR SOAP SOAP SOAP SOAP DISPENSERDISPENSERDISPENSERDISPENSER HIGHEST OPERABLE PARTHIGHEST OPERABLE PARTHIGHEST OPERABLE PARTHIGHEST OPERABLE PART 16" MIN16" MIN16" MIN16" MIN 18" MAX18" MAX18" MAX18" MAX 12" MIN12" MIN12" MIN12" MIN 24" MIN24" MIN24" MIN24" MIN 36" LONG MIN36" LONG MIN36" LONG MIN36" LONG MIN 33 " M I N 33 " M I N 33 " M I N 33 " M I N 36 " M A X 36 " M A X 36 " M A X 36 " M A X C.L.C.L.C.L.C.L. 17 " M I N 17 " M I N 17 " M I N 17 " M I N 19 " M A X 19 " M A X 19 " M A X 19 " M A X 48 " M A X 48 " M A X 48 " M A X 48 " M A X 7"MIN7"MIN7"MIN7"MIN 9"MAX9"MAX9"MAX9"MAX 15 " M I N 15 " M I N 15 " M I N 15 " M I N 48 " M A X 48 " M A X 48 " M A X 48 " M A X 12"MAX12"MAX12"MAX12"MAX42" LONG MIN42" LONG MIN42" LONG MIN42" LONG MIN 33 " M I N 33 " M I N 33 " M I N 33 " M I N 36 " M A X 36 " M A X 36 " M A X 36 " M A X 1-1/2" CLEARANCE1-1/2" CLEARANCE1-1/2" CLEARANCE1-1/2" CLEARANCE 1.25-2" OUTSIDE DIAMETER1.25-2" OUTSIDE DIAMETER1.25-2" OUTSIDE DIAMETER1.25-2" OUTSIDE DIAMETER 39 " - 4 1 " 39 " - 4 1 " 39 " - 4 1 " 39 " - 4 1 " 18 " M I N 18 " M I N 18 " M I N 18 " M I N CAN BE SINGLECAN BE SINGLECAN BE SINGLECAN BE SINGLE GRAB BARGRAB BARGRAB BARGRAB BAR CAN BE SINGLECAN BE SINGLECAN BE SINGLECAN BE SINGLE GRAB BARGRAB BARGRAB BARGRAB BAR 4 MAIN STORY ADAMAIN STORY ADAMAIN STORY ADAMAIN STORY ADA SCALE: SCALE: SCALE: SCALE: 1/4" = 1'-0"1/4" = 1'-0"1/4" = 1'-0"1/4" = 1'-0" 5 904 GENERAL SINK SIDE ADA904 GENERAL SINK SIDE ADA904 GENERAL SINK SIDE ADA904 GENERAL SINK SIDE ADA NOT TO NOT TO NOT TO NOT TO SCALESCALESCALESCALE 6 903 GENERAL SINK FRONT ADA903 GENERAL SINK FRONT ADA903 GENERAL SINK FRONT ADA903 GENERAL SINK FRONT ADA NOT TO NOT TO NOT TO NOT TO SCALESCALESCALESCALE 7 901 GENERAL TOILET FRONT ADA901 GENERAL TOILET FRONT ADA901 GENERAL TOILET FRONT ADA901 GENERAL TOILET FRONT ADA NOT TO NOT TO NOT TO NOT TO SCALESCALESCALESCALE 8 902 GENERAL TOILET SIDE ADA902 GENERAL TOILET SIDE ADA902 GENERAL TOILET SIDE ADA902 GENERAL TOILET SIDE ADA NOT TO NOT TO NOT TO NOT TO SCALESCALESCALESCALE COLOR LEGENDCOLOR LEGENDCOLOR LEGENDCOLOR LEGEND :::: TOILET CLEARANCETOILET CLEARANCETOILET CLEARANCETOILET CLEARANCE :::: SINK CLEARANCESINK CLEARANCESINK CLEARANCESINK CLEARANCE :::: TURNING RADIUSTURNING RADIUSTURNING RADIUSTURNING RADIUS :::: DOOR CLEARANCEDOOR CLEARANCEDOOR CLEARANCEDOOR CLEARANCE Seating at tables, counters, and work areas need to comply with section 1109.11 DE S C R I P T I O N RE V I S I O N D A T E MA I N L E V E L SH E E T T I T L E : A-101 PLN# 21-10-031 DR A W N B Y : CH K ' D B Y : D. M . #1 - 5 C h e c k e d B y PL O T D A T E : 1/ 1 3 / 2 0 2 2 EN G I N E E R : R A Y M C D O U G A L , P E EI T : # 1 - 4 E N G I N E E R I N T E R N 1/13/2022 12 7 E . M a i n S t . S u i t e 1 1 1 Re x b u r g , I D 8 3 4 4 0 ww w . s o u t h f o r k d e s i g n . c o m 20 8 - 8 5 2 - 6 2 3 6 So u t h F o r k D e s i g n G r o u p , L L C VE T C L I N I C #1 - 1 C L I E N T A D D R E S S #1 - 2 C L I E N T A D D R E S S THESE PLANS ARE STAMPED/ENGINEERED FOR THE LOCATION SPECIFIED. IF LOCATION CHANGES REENGINEERING IS REQUIRED. Co p y r i g h t 2 0 2 2 | S o u t h f o r k E n g i n e e r i n g | A l l R i g h t s R e s e r v e d . UP 1 2 2 2 2 2 2 2 2 22 2 W DR 7'-67'-67'-67'-6 1/2"1/2"1/2"1/2"10'-510'-510'-510'-5 1/2"1/2"1/2"1/2"8'-68'-68'-68'-6 1/2"1/2"1/2"1/2"11'-711'-711'-711'-7 1/2"1/2"1/2"1/2" 5'-75'-75'-75'-7 1/2"1/2"1/2"1/2" 9'-79'-79'-79'-7 1/2"1/2"1/2"1/2"7'-77'-77'-77'-7 1/2"1/2"1/2"1/2" 21'-721'-721'-721'-7 1/2"1/2"1/2"1/2" 7' - 1 7' - 1 7' - 1 7' - 1 1/ 2 " 1/ 2 " 1/ 2 " 1/ 2 " 10 ' - 1 0 10 ' - 1 0 10 ' - 1 0 10 ' - 1 0 1/ 2 " 1/ 2 " 1/ 2 " 1/ 2 " 23 ' - 1 1 23 ' - 1 1 23 ' - 1 1 23 ' - 1 1 1/ 2 " 1/ 2 " 1/ 2 " 1/ 2 " 33'-733'-733'-733'-7 1/2"1/2"1/2"1/2" 2 A- 3 0 1 2 A- 3 0 1 1 A-301 1 A-301 EXTERIOR WALLS ANDEXTERIOR WALLS ANDEXTERIOR WALLS ANDEXTERIOR WALLS AND ROOF STRUCTURE ROOF STRUCTURE ROOF STRUCTURE ROOF STRUCTURE BYBYBYBY STEEL MANUFACTURERSTEEL MANUFACTURERSTEEL MANUFACTURERSTEEL MANUFACTURER UTILITYUTILITYUTILITYUTILITY BREEZEWAYBREEZEWAYBREEZEWAYBREEZEWAY EMPLOYEE BATHEMPLOYEE BATHEMPLOYEE BATHEMPLOYEE BATH CUSTOMERCUSTOMERCUSTOMERCUSTOMER BATHBATHBATHBATH COOLERCOOLERCOOLERCOOLER STORAGESTORAGESTORAGESTORAGE OFFICEOFFICEOFFICEOFFICE/CONFERENCE/CONFERENCE/CONFERENCE/CONFERENCE ROOMROOMROOMROOM OFFICEOFFICEOFFICEOFFICEOFFICEOFFICEOFFICEOFFICE//// STORAGESTORAGESTORAGESTORAGE WAREHOUSEWAREHOUSEWAREHOUSEWAREHOUSE MERCH.MERCH.MERCH.MERCH. DOOR SCHEDULEDOOR SCHEDULEDOOR SCHEDULEDOOR SCHEDULE ID 1 2 QTY 1 20 LOCATION Interior Interior FIRE RATING DOOR W 6' 3' HT 6'-8" 6'-8" NOTES 3 MAIN LEVEL PLANMAIN LEVEL PLANMAIN LEVEL PLANMAIN LEVEL PLAN SCALE: SCALE: SCALE: SCALE: 1/4" = 1'-0"1/4" = 1'-0"1/4" = 1'-0"1/4" = 1'-0" DE S C R I P T I O N RE V I S I O N D A T E SE C O N D L E V E L SH E E T T I T L E : A-102 PLN# 21-10-031 DR A W N B Y : CH K ' D B Y : D. M . #1 - 5 C h e c k e d B y PL O T D A T E : 1/ 1 3 / 2 0 2 2 EN G I N E E R : R A Y M C D O U G A L , P E EI T : # 1 - 4 E N G I N E E R I N T E R N 1/13/2022 12 7 E . M a i n S t . S u i t e 1 1 1 Re x b u r g , I D 8 3 4 4 0 ww w . s o u t h f o r k d e s i g n . c o m 20 8 - 8 5 2 - 6 2 3 6 So u t h F o r k D e s i g n G r o u p , L L C VE T C L I N I C #1 - 1 C L I E N T A D D R E S S #1 - 2 C L I E N T A D D R E S S THESE PLANS ARE STAMPED/ENGINEERED FOR THE LOCATION SPECIFIED. IF LOCATION CHANGES REENGINEERING IS REQUIRED. Co p y r i g h t 2 0 2 2 | S o u t h f o r k E n g i n e e r i n g | A l l R i g h t s R e s e r v e d . DOWN 2 2 2 2 2 2 2 2 2 2 A- 3 0 1 2 A- 3 0 1 1 A-301 1 A-301 9' - 4 9' - 4 9' - 4 9' - 4 1/ 2 " 1/ 2 " 1/ 2 " 1/ 2 " 9' - 7 9' - 7 9' - 7 9' - 7 1/ 2 " 1/ 2 " 1/ 2 " 1/ 2 " 5' - 7 5' - 7 5' - 7 5' - 7 1/ 2 " 1/ 2 " 1/ 2 " 1/ 2 " 13'-713'-713'-713'-7 1/2"1/2"1/2"1/2" 19'-719'-719'-719'-7 1/2"1/2"1/2"1/2" 21 ' - 1 0 " 21 ' - 1 0 " 21 ' - 1 0 " 21 ' - 1 0 " 19 ' - 6 " 19 ' - 6 " 19 ' - 6 " 19 ' - 6 " 8' - 2 8' - 2 8' - 2 8' - 2 1/ 2 " 1/ 2 " 1/ 2 " 1/ 2 " 20 ' - 1 20 ' - 1 20 ' - 1 20 ' - 1 1/ 2 " 1/ 2 " 1/ 2 " 1/ 2 " EXTERIOR WALLS ANDEXTERIOR WALLS ANDEXTERIOR WALLS ANDEXTERIOR WALLS AND ROOF STRUCTURE ROOF STRUCTURE ROOF STRUCTURE ROOF STRUCTURE BYBYBYBY STEEL MANUFACTURERSTEEL MANUFACTURERSTEEL MANUFACTURERSTEEL MANUFACTURER CONFERENCECONFERENCECONFERENCECONFERENCE OWNER'S OWNER'S OWNER'S OWNER'S OFFICEOFFICEOFFICEOFFICE BATHROOMBATHROOMBATHROOMBATHROOM OWNER'S FLEX ROOMOWNER'S FLEX ROOMOWNER'S FLEX ROOMOWNER'S FLEX ROOM STORAGESTORAGESTORAGESTORAGE OWNER'S OWNER'S OWNER'S OWNER'S OFFICEOFFICEOFFICEOFFICE DOOR SCHEDULEDOOR SCHEDULEDOOR SCHEDULEDOOR SCHEDULE ID 1 2 QTY 1 20 LOCATION Interior Interior FIRE RATING DOOR W 6' 3' HT 6'-8" 6'-8" NOTES 1 SECOND LEVEL PLANSECOND LEVEL PLANSECOND LEVEL PLANSECOND LEVEL PLAN SCALE: SCALE: SCALE: SCALE: 1/4" = 1'-0"1/4" = 1'-0"1/4" = 1'-0"1/4" = 1'-0" DE S C R I P T I O N RE V I S I O N D A T E SE C T I O N S SH E E T T I T L E : A-301 PLN# 21-10-031 DR A W N B Y : CH K ' D B Y : D. M . #1 - 5 C h e c k e d B y PL O T D A T E : 1/ 1 3 / 2 0 2 2 EN G I N E E R : R A Y M C D O U G A L , P E EI T : # 1 - 4 E N G I N E E R I N T E R N 1/13/2022 12 7 E . M a i n S t . S u i t e 1 1 1 Re x b u r g , I D 8 3 4 4 0 ww w . s o u t h f o r k d e s i g n . c o m 20 8 - 8 5 2 - 6 2 3 6 So u t h F o r k D e s i g n G r o u p , L L C VE T C L I N I C #1 - 1 C L I E N T A D D R E S S #1 - 2 C L I E N T A D D R E S S THESE PLANS ARE STAMPED/ENGINEERED FOR THE LOCATION SPECIFIED. IF LOCATION CHANGES REENGINEERING IS REQUIRED. Co p y r i g h t 2 0 2 2 | S o u t h f o r k E n g i n e e r i n g | A l l R i g h t s R e s e r v e d . 9' - 9' - 9' - 9' - 1/ 8 " 1/ 8 " 1/ 8 " 1/ 8 " 7' - 1 1 " 7' - 1 1 " 7' - 1 1 " 7' - 1 1 " EXTERIOR STEEL WALLSEXTERIOR STEEL WALLSEXTERIOR STEEL WALLSEXTERIOR STEEL WALLS BY SEPERATE STEELBY SEPERATE STEELBY SEPERATE STEELBY SEPERATE STEEL BUILDING PLANSBUILDING PLANSBUILDING PLANSBUILDING PLANS 7' - 1 1 " 7' - 1 1 " 7' - 1 1 " 7' - 1 1 " 9' - 9' - 9' - 9' - 5/ 8 " 5/ 8 " 5/ 8 " 5/ 8 " EXTERIOR WALLS ANDEXTERIOR WALLS ANDEXTERIOR WALLS ANDEXTERIOR WALLS AND ROOF STRUCTURE ROOF STRUCTURE ROOF STRUCTURE ROOF STRUCTURE BYBYBYBY STEEL MANUFACTURERSTEEL MANUFACTURERSTEEL MANUFACTURERSTEEL MANUFACTURER EXTERIOR EXTERIOR EXTERIOR EXTERIOR FOUNDATIONFOUNDATIONFOUNDATIONFOUNDATION BYBYBYBY STEEL MANUFACTURERSTEEL MANUFACTURERSTEEL MANUFACTURERSTEEL MANUFACTURER 1 SECTION BSECTION BSECTION BSECTION B SCALE: SCALE: SCALE: SCALE: 1/4" = 1'-0"1/4" = 1'-0"1/4" = 1'-0"1/4" = 1'-0" 2 SECTION ASECTION ASECTION ASECTION A SCALE: SCALE: SCALE: SCALE: 1/4" = 1'-0"1/4" = 1'-0"1/4" = 1'-0"1/4" = 1'-0" DE S C R I P T I O N RE V I S I O N D A T E FO U N D A T I O N SH E E T T I T L E : S-101 PLN# 21-10-031 DR A W N B Y : CH K ' D B Y : D. M . #1 - 5 C h e c k e d B y PL O T D A T E : 1/ 1 3 / 2 0 2 2 EN G I N E E R : R A Y M C D O U G A L , P E EI T : # 1 - 4 E N G I N E E R I N T E R N 1/13/2022 12 7 E . M a i n S t . S u i t e 1 1 1 Re x b u r g , I D 8 3 4 4 0 ww w . s o u t h f o r k d e s i g n . c o m 20 8 - 8 5 2 - 6 2 3 6 So u t h F o r k D e s i g n G r o u p , L L C VE T C L I N I C #1 - 1 C L I E N T A D D R E S S #1 - 2 C L I E N T A D D R E S S THESE PLANS ARE STAMPED/ENGINEERED FOR THE LOCATION SPECIFIED. IF LOCATION CHANGES REENGINEERING IS REQUIRED. Co p y r i g h t 2 0 2 2 | S o u t h f o r k E n g i n e e r i n g | A l l R i g h t s R e s e r v e d . 100'100'100'100' 100'100'100'100' 50 ' 50 ' 50 ' 50 ' 50 ' 50 ' 50 ' 50 ' 17 ' - 17 ' - 17 ' - 17 ' - 1/ 4 " 1/ 4 " 1/ 4 " 1/ 4 " 5'5'5'5' 5'5'5'5' 2' - 2 2' - 2 2' - 2 2' - 2 3/ 4 " 3/ 4 " 3/ 4 " 3/ 4 " 8' - 1 " 8' - 1 " 8' - 1 " 8' - 1 " 4'4'4'4' 7' - 4 " 7' - 4 " 7' - 4 " 7' - 4 " 28'-928'-928'-928'-9 3/4"3/4"3/4"3/4"12'12'12'12' 1'-4"1'-4"1'-4"1'-4" 28'28'28'28'28'-628'-628'-628'-6 1/4"1/4"1/4"1/4" 25'-525'-525'-525'-5 1/4"1/4"1/4"1/4"4'-4'-4'-4'-1/4"1/4"1/4"1/4"17'-17'-17'-17'-3/8"3/8"3/8"3/8"17'17'17'17'5'-115'-115'-115'-11 7/8"7/8"7/8"7/8"29'-229'-229'-229'-21/4"1/4"1/4"1/4" 29 ' - 3 " 29 ' - 3 " 29 ' - 3 " 29 ' - 3 " 19 ' - 5 " 19 ' - 5 " 19 ' - 5 " 19 ' - 5 " 30'-10"30'-10"30'-10"30'-10" 29'-6"29'-6"29'-6"29'-6" 1'-4"1'-4"1'-4"1'-4" 3'-2"3'-2"3'-2"3'-2" 1'-4"1'-4"1'-4"1'-4" 6'6'6'6'28'-628'-628'-628'-6 1/4"1/4"1/4"1/4" 5'-10"5'-10"5'-10"5'-10" 7'-4"7'-4"7'-4"7'-4" EXTERIOR EXTERIOR EXTERIOR EXTERIOR FOUNDATION BYFOUNDATION BYFOUNDATION BYFOUNDATION BY STEEL BUILDING PLANSTEEL BUILDING PLANSTEEL BUILDING PLANSTEEL BUILDING PLAN F5F5F5F5 F12F12F12F12 F5F5F5F5 F5F5F5F5 F9F9F9F9 F9F9F9F9 F12F12F12F12 SIMPSON ABUSIMPSON ABUSIMPSON ABUSIMPSON ABU POST BASESPOST BASESPOST BASESPOST BASES SIMPSON ABUSIMPSON ABUSIMPSON ABUSIMPSON ABU POST BASESPOST BASESPOST BASESPOST BASES F10F10F10F10F12F12F12F12 F5F5F5F5 F5F5F5F5 ALL INTERIOR FOOTINGSALL INTERIOR FOOTINGSALL INTERIOR FOOTINGSALL INTERIOR FOOTINGS MAY BE THICKENED SLAB FOOTINGSMAY BE THICKENED SLAB FOOTINGSMAY BE THICKENED SLAB FOOTINGSMAY BE THICKENED SLAB FOOTINGS 2 A- 3 0 1 2 A- 3 0 1 1 A-301 1 A-301 FOOTING SCHEDULEFOOTING SCHEDULEFOOTING SCHEDULEFOOTING SCHEDULE IDIDIDID F5 F9 F10 F12 WIDTHWIDTHWIDTHWIDTH 20" 24" 30" 48" DEPTHDEPTHDEPTHDEPTH 10" 10" 10" 12" FOOTING TYPEFOOTING TYPEFOOTING TYPEFOOTING TYPE CONTINUOUS FOOTING 24” X 24” X 10” SPREAD FOOTER 30” X 30” X 10” SPREAD FOOTER 48” X 48” X 12” SPREAD FOOTER FOOTING REBARFOOTING REBARFOOTING REBARFOOTING REBAR (2) #4 BAR CONT. (3) #4 BOTH WAYS (3) #4 BOTH WAYS (4) #5 BOTH WAYS PIER (IF REQUIRED)PIER (IF REQUIRED)PIER (IF REQUIRED)PIER (IF REQUIRED) --- --- --- --- 3 FOUNDATION PLANFOUNDATION PLANFOUNDATION PLANFOUNDATION PLAN SCALE: SCALE: SCALE: SCALE: 1/4" = 1'-0"1/4" = 1'-0"1/4" = 1'-0"1/4" = 1'-0" FOUNDATION NOTE:FOUNDATION NOTE:FOUNDATION NOTE:FOUNDATION NOTE: 1. SEE FOUNDATION WALL SCHEDULE FOR FOUNDATION WALL SIZE, REBAR SPACING, & J-BOLT/ ANCHOR LOCATIONS. 2. PRESSURE TREATED SILL PLATE AT PERIMETER OF FOUNDATION 3. SEE FOOTING SCHEDULE FOR FOOTING SIZE AND REBAR PLACEMENT. ALL FOOTINGS TO BEAR ON APPROVED STRUCTURAL FILL OR UNDISTURBED SOIL. 4. FOOTING DESIGN IS BASED ON SOIL LOAD-BEARING CAPACITY OF 1500 PSF. IF CONTRACTORS ENCOUNTER EXPANSIVE SOILS OR OTHER PROBLEMS, THE SITE MUST BE APPROVED BY A SOILS ENGINEER PRIOR TO POURING FOOTINGS IN THAT AREA. 5. CONCRETE FOR FOOTINGS AND FOUNDATION WALLS TO HAVE A 28 DAY COMPRESSIVE STRENGTH OF 3000 PSI. 2500 PSI USED IN DESIGN, THEREFORE NO SPECIAL INSPECTIONS. 6. LAP REBAR SPLICES 30 BAR DIAMETERS U.N.O. 7. REINFORCING STEEL SHALL BE GRADE 60 FOR #4 BAR & LARGER BUT MAY BE GRADE 40 FOR #3 AND SMALLER BARS . 8. DAMP PROOFING PER 2018 IRC SECTION 406 9. CRAWL SPACE VENTALATION @ 1:150 RATIO & PLACE (1) VENT WITHIN 3' OF EACH CORNER. 10. 18" X 24" MINIMUM CRAWLSPACE ACCESS HOLE. 11. THE THICKNESS OF CONCRETE FLOOR SLABS SUPPORTED DIRECTLY ON THE GROUND SHALL NOT BE LESS THAN 3.5" (98 MM). A6-MIL (0.006 INCH; 0.15 MM) POLYETHYLENE VAPOR RETARDER. CONTROL JOINTS @ 25' O.C. MAX EA. DIR. OR CENTERED PER OWNER PREFERENCE. Finished grade to slope 6" in first 10'. DE S C R I P T I O N RE V I S I O N D A T E 2N D F L O O R F R A M I N G SH E E T T I T L E : S-201 PLN# 21-10-031 DR A W N B Y : CH K ' D B Y : D. M . #1 - 5 C h e c k e d B y PL O T D A T E : 1/ 1 3 / 2 0 2 2 EN G I N E E R : R A Y M C D O U G A L , P E EI T : # 1 - 4 E N G I N E E R I N T E R N 1/13/2022 12 7 E . M a i n S t . S u i t e 1 1 1 Re x b u r g , I D 8 3 4 4 0 ww w . s o u t h f o r k d e s i g n . c o m 20 8 - 8 5 2 - 6 2 3 6 So u t h F o r k D e s i g n G r o u p , L L C VE T C L I N I C #1 - 1 C L I E N T A D D R E S S #1 - 2 C L I E N T A D D R E S S THESE PLANS ARE STAMPED/ENGINEERED FOR THE LOCATION SPECIFIED. IF LOCATION CHANGES REENGINEERING IS REQUIRED. Co p y r i g h t 2 0 2 2 | S o u t h f o r k E n g i n e e r i n g | A l l R i g h t s R e s e r v e d . 2 A- 3 0 1 2 A- 3 0 1 1 A-301 1 A-301 1 3/4" X 11 7/8" LVL1 3/4" X 11 7/8" LVL1 3/4" X 11 7/8" LVL1 3/4" X 11 7/8" LVL SIMPSON ITS HANGERSSIMPSON ITS HANGERSSIMPSON ITS HANGERSSIMPSON ITS HANGERS (TYP) (TYP) (TYP) (TYP) WEB STIFFENERS FORWEB STIFFENERS FORWEB STIFFENERS FORWEB STIFFENERS FOR CANTILVER JOISTSCANTILVER JOISTSCANTILVER JOISTSCANTILVER JOISTS 6 3/4" X 16 1/2" 6 3/4" X 16 1/2" 6 3/4" X 16 1/2" 6 3/4" X 16 1/2" GLULAM GLULAM GLULAM GLULAM 24F-V424F-V424F-V424F-V4 SIMPSON ITS HANGERSSIMPSON ITS HANGERSSIMPSON ITS HANGERSSIMPSON ITS HANGERS (TYP) (TYP) (TYP) (TYP) 11 7/8" TJI 210 @ 16" O.C.11 7/8" TJI 210 @ 16" O.C.11 7/8" TJI 210 @ 16" O.C.11 7/8" TJI 210 @ 16" O.C. PROVIDE SQUASH BLOCKING THROUGH FLOOR WHERE BEARING ISPROVIDE SQUASH BLOCKING THROUGH FLOOR WHERE BEARING ISPROVIDE SQUASH BLOCKING THROUGH FLOOR WHERE BEARING ISPROVIDE SQUASH BLOCKING THROUGH FLOOR WHERE BEARING IS REQUIRED ABOVE. INSTALL PER MANUFACTURER'S SPEC. 3/4" T&G OSBREQUIRED ABOVE. INSTALL PER MANUFACTURER'S SPEC. 3/4" T&G OSBREQUIRED ABOVE. INSTALL PER MANUFACTURER'S SPEC. 3/4" T&G OSBREQUIRED ABOVE. INSTALL PER MANUFACTURER'S SPEC. 3/4" T&G OSB w/ GLUE AND 10d RING SHANK NAILS 3/12 SPACING (TYP)w/ GLUE AND 10d RING SHANK NAILS 3/12 SPACING (TYP)w/ GLUE AND 10d RING SHANK NAILS 3/12 SPACING (TYP)w/ GLUE AND 10d RING SHANK NAILS 3/12 SPACING (TYP) 3 SECOND FLOOR FRAMINGSECOND FLOOR FRAMINGSECOND FLOOR FRAMINGSECOND FLOOR FRAMING SCALE: SCALE: SCALE: SCALE: 1/4" = 1'-0"1/4" = 1'-0"1/4" = 1'-0"1/4" = 1'-0" Floor joist and cantilever joist to meet manufacturer specifications. DE S C R I P T I O N RE V I S I O N D A T E MA I N L . W A L L F R A M I N G SH E E T T I T L E : S-301 PLN# 21-10-031 DR A W N B Y : CH K ' D B Y : D. M . #1 - 5 C h e c k e d B y PL O T D A T E : 1/ 1 3 / 2 0 2 2 EN G I N E E R : R A Y M C D O U G A L , P E EI T : # 1 - 4 E N G I N E E R I N T E R N 1/13/2022 12 7 E . M a i n S t . S u i t e 1 1 1 Re x b u r g , I D 8 3 4 4 0 ww w . s o u t h f o r k d e s i g n . c o m 20 8 - 8 5 2 - 6 2 3 6 So u t h F o r k D e s i g n G r o u p , L L C VE T C L I N I C #1 - 1 C L I E N T A D D R E S S #1 - 2 C L I E N T A D D R E S S THESE PLANS ARE STAMPED/ENGINEERED FOR THE LOCATION SPECIFIED. IF LOCATION CHANGES REENGINEERING IS REQUIRED. Co p y r i g h t 2 0 2 2 | S o u t h f o r k E n g i n e e r i n g | A l l R i g h t s R e s e r v e d . UP 1 2 2 2 2 2 2 2 2 22 2 W DR 100'100'100'100' 100'100'100'100' 50 ' 50 ' 50 ' 50 ' 50 ' 50 ' 50 ' 50 ' 30'30'30'30'12'12'12'12'7'-11"7'-11"7'-11"7'-11"11'11'11'11'9'-1"9'-1"9'-1"9'-1"30'30'30'30' 30'30'30'30'22'22'22'22'8'8'8'8'10'10'10'10'30'30'30'30' 12 ' - 1 0 " 12 ' - 1 0 " 12 ' - 1 0 " 12 ' - 1 0 " 5'5'5'5' 20 ' - 3 " 20 ' - 3 " 20 ' - 3 " 20 ' - 3 " 4' - 1 " 4' - 1 " 4' - 1 " 4' - 1 " 7' - 1 0 " 7' - 1 0 " 7' - 1 0 " 7' - 1 0 " 17'-2"17'-2"17'-2"17'-2"12'-4"12'-4"12'-4"12'-4"4'-6"4'-6"4'-6"4'-6" 12 ' - 1 " 12 ' - 1 " 12 ' - 1 " 12 ' - 1 " 12 ' - 3 " 12 ' - 3 " 12 ' - 3 " 12 ' - 3 " 6'6'6'6'29'-4"29'-4"29'-4"29'-4" 5'5'5'5' 2' - 1 " 2' - 1 " 2' - 1 " 2' - 1 " 10 ' 10 ' 10 ' 10 ' 12 ' - 3 " 12 ' - 3 " 12 ' - 3 " 12 ' - 3 " 7' - 1 0 " 7' - 1 0 " 7' - 1 0 " 7' - 1 0 " 12 ' - 1 " 12 ' - 1 " 12 ' - 1 " 12 ' - 1 " 8' - 2 " 8' - 2 " 8' - 2 " 8' - 2 " 4'4'4'4'3'-11"3'-11"3'-11"3'-11" 2 A- 3 0 1 2 A- 3 0 1 1 A-301 1 A-301 H7H7H7H7 H7H7H7H7 H7H7H7H7 H7H7H7H7 H7H7H7H7 C7C7C7C7 C7C7C7C7 C9C9C9C9 2X4 WOOD-FRAMED2X4 WOOD-FRAMED2X4 WOOD-FRAMED2X4 WOOD-FRAMED WALLS WITH GYPSONWALLS WITH GYPSONWALLS WITH GYPSONWALLS WITH GYPSON BOARD TYP.BOARD TYP.BOARD TYP.BOARD TYP. U.N.O. U.N.O. U.N.O. U.N.O. 2X2X2X2X6666 WOOD- WOOD- WOOD- WOOD- FRAMEDFRAMEDFRAMEDFRAMED WALLWALLWALLWALL 2X2X2X2X6666 WOOD- WOOD- WOOD- WOOD- FRAMEDFRAMEDFRAMEDFRAMED WALLWALLWALLWALL C12C12C12C12 C2C2C2C2C12C12C12C12 5/8" TYPE X5/8" TYPE X5/8" TYPE X5/8" TYPE X GYPSOMEGYPSOMEGYPSOMEGYPSOME BOARDBOARDBOARDBOARD 5/8" TYPE X5/8" TYPE X5/8" TYPE X5/8" TYPE X GYPSOMEGYPSOMEGYPSOMEGYPSOME BOARDBOARDBOARDBOARD EXTERIOR WALLS ANDEXTERIOR WALLS ANDEXTERIOR WALLS ANDEXTERIOR WALLS AND ROOF STRUCTURE ROOF STRUCTURE ROOF STRUCTURE ROOF STRUCTURE BYBYBYBY STEEL MANUFACTURERSTEEL MANUFACTURERSTEEL MANUFACTURERSTEEL MANUFACTURER COOLER DOORCOOLER DOORCOOLER DOORCOOLER DOOR BY OTHERBY OTHERBY OTHERBY OTHER UTILITYUTILITYUTILITYUTILITY BREEZEWAYBREEZEWAYBREEZEWAYBREEZEWAY EMPLOYEE BATHEMPLOYEE BATHEMPLOYEE BATHEMPLOYEE BATH CUSTOMERCUSTOMERCUSTOMERCUSTOMER BATHBATHBATHBATH COOLERCOOLERCOOLERCOOLER STORAGESTORAGESTORAGESTORAGE OFFICEOFFICEOFFICEOFFICE/CONFERENCE/CONFERENCE/CONFERENCE/CONFERENCE ROOMROOMROOMROOM OFFICEOFFICEOFFICEOFFICEOFFICEOFFICEOFFICEOFFICE//// STORAGESTORAGESTORAGESTORAGE WAREHOUSEWAREHOUSEWAREHOUSEWAREHOUSE MERCH.MERCH.MERCH.MERCH. HEADERSHEADERSHEADERSHEADERS IDIDIDID H7 PLYPLYPLYPLY 2 SIZESIZESIZESIZE 2X8 SPF NOTENOTENOTENOTE COLUMN SCHEDULECOLUMN SCHEDULECOLUMN SCHEDULECOLUMN SCHEDULE IDIDIDID C2 C7 C9 C12 MATERIALMATERIALMATERIALMATERIAL (4) 2X4 SPF #2 OR BETTER 4X4 SPF #1 OR BETTER 8X8 SPF #1 OR BETTER 3 1/8" X 12" GLULAM 24V-4F 1111 2222 3333 4444 55556666 7777 88889999 10101010 11111111 12121212 14141414 13131313 CEILING OF NEXT LEVEL KEYNOTES:KEYNOTES:KEYNOTES:KEYNOTES: 1 - 6'8" HEAD CLEARANCE ENTIRETY OF STAIRS 2 - HANDRAIL 36" VERTICALLY FROM STAIR NOISING 3 - 7-3/4" MAX RISE 4 - 10" MIN RUN 5 - 2X CLEAT. PRESSURE TREATED IF FLOOR IS CONCRETE 6 - DRY WALL 7 - LVL STRINGER 8 - SIMPSON SLOP ABLE HANGER 9- FLOOR FRAMING 10 - RIM BOARD 11 - LVL DROPPED TO MATCH STRINGERS 12 - FILLER BLOCK 13 - MAX 4" GAP 14 - 42" MIN GUARD RAIL 4 MAIN LEVEL WALL FRAMINGMAIN LEVEL WALL FRAMINGMAIN LEVEL WALL FRAMINGMAIN LEVEL WALL FRAMING SCALE: SCALE: SCALE: SCALE: 1/4" = 1'-0"1/4" = 1'-0"1/4" = 1'-0"1/4" = 1'-0" 7 401-TYPICAL RESIDENTIAL STAIR FRAMING401-TYPICAL RESIDENTIAL STAIR FRAMING401-TYPICAL RESIDENTIAL STAIR FRAMING401-TYPICAL RESIDENTIAL STAIR FRAMING NOT TO NOT TO NOT TO NOT TO SCALESCALESCALESCALEGENERAL FRAMING NOTE:GENERAL FRAMING NOTE:GENERAL FRAMING NOTE:GENERAL FRAMING NOTE: 1. EXTERIOR WALL FRAMING SHALL BE CONVENTIONAL 2x6 FRAMING @ 16" O.C. U.N.O. 2. IF LUMBER GRADING IS NOT SPECIFIED, ASSUME SPF#2 OR BETTER. 3. SEE SHEAR OR BRACE WALL PANEL SCHEDULE FOR WALL SHEATHING AND FASTENING. 4. ENSURE THAT WALLS TALLER THAN 10' HAVE BLOCKING @ PANEL EDGES AND FIRE BLOCKING. 5. ENSURE THAT INTERIOR BEARING WALLS ARE SUPPORTED IN FLOOR BY BLOCKING OR DOUBLE JOISTS. 6. ENSURE THAT COLUMNS INDICATED ON MAIN OR UPPER FLOORS ARE DIRECTLY SUPPORT BY BEAMS OR COLUMNS IN LOWER FLOORS OR SOLID BLOCKING. PROVIDE POSITIVE CONNECTIONS BETWEEN UPPER AND LOWER. 7. INSTALL ALL HANGERS, HOLD DOWNS, TIES, AND ANCHORS & CAPS AS SPECIFIED IN MANUFACTURER DOCUMENTATION. 8. ENSURE THAT WINDOWS & DOORS ARE FLASHED AND SEALED OVER AN APPROVED WALL/ROOFING MEMBRANE TO ENSURE MOISTURE PROTECTION 9. INSTALL SIDING PER MANUFACTURER REQ., INCLUDING RAIN SCREEN OR OTHER. 10. ALL STAIRS SHALL BE CONVENTIONAL IN CONSTRUCTION WITH A MAX RISE OF 7 3/4" AND A MINIMUM RUN OF 10". 11. PROVIDE GUARD RAILS @ 36" FROM NOSING , AND HANDRAILS AT THE SAME. 7" max 11" min All wood in contact with concrete needs to be pressure treated. Handrails and guards need to meet the requirements of IBC section 1014 and 1015. Stairs to be protected as per section 1023. DE S C R I P T I O N RE V I S I O N D A T E 2N D L . W A L L F R A M I N G SH E E T T I T L E : S-302 PLN# 21-10-031 DR A W N B Y : CH K ' D B Y : D. M . #1 - 5 C h e c k e d B y PL O T D A T E : 1/ 1 3 / 2 0 2 2 EN G I N E E R : R A Y M C D O U G A L , P E EI T : # 1 - 4 E N G I N E E R I N T E R N 1/13/2022 12 7 E . M a i n S t . S u i t e 1 1 1 Re x b u r g , I D 8 3 4 4 0 ww w . s o u t h f o r k d e s i g n . c o m 20 8 - 8 5 2 - 6 2 3 6 So u t h F o r k D e s i g n G r o u p , L L C VE T C L I N I C #1 - 1 C L I E N T A D D R E S S #1 - 2 C L I E N T A D D R E S S THESE PLANS ARE STAMPED/ENGINEERED FOR THE LOCATION SPECIFIED. IF LOCATION CHANGES REENGINEERING IS REQUIRED. Co p y r i g h t 2 0 2 2 | S o u t h f o r k E n g i n e e r i n g | A l l R i g h t s R e s e r v e d . DOWN 2 2 2 2 2 2 2 2 2 2 A- 3 0 1 2 A- 3 0 1 1 A-301 1 A-301 100'-100'-100'-100'-7/8"7/8"7/8"7/8" 100'-100'-100'-100'-7/8"7/8"7/8"7/8" 29'-1129'-1129'-1129'-11 7/8"7/8"7/8"7/8"20'20'20'20'6'6'6'6'14'14'14'14'29'-429'-429'-429'-4 1/2"1/2"1/2"1/2" 29'-1129'-1129'-1129'-11 7/8"7/8"7/8"7/8"20'20'20'20'6'6'6'6'14'14'14'14'30'-30'-30'-30'-7/8"7/8"7/8"7/8" 50 ' - 50 ' - 50 ' - 50 ' - 7/ 8 " 7/ 8 " 7/ 8 " 7/ 8 " 22 ' - 1 0 22 ' - 1 0 22 ' - 1 0 22 ' - 1 0 7/ 8 " 7/ 8 " 7/ 8 " 7/ 8 " 6'6'6'6' 21 ' - 1 21 ' - 1 21 ' - 1 21 ' - 1 7/ 8 " 7/ 8 " 7/ 8 " 7/ 8 " 20 ' - 1 0 20 ' - 1 0 20 ' - 1 0 20 ' - 1 0 7/ 8 " 7/ 8 " 7/ 8 " 7/ 8 " 10 ' 10 ' 10 ' 10 ' 5' - 4 " 5' - 4 " 5' - 4 " 5' - 4 " 4' - 7 " 4' - 7 " 4' - 7 " 4' - 7 " 9' - 2 9' - 2 9' - 2 9' - 2 7/ 8 " 7/ 8 " 7/ 8 " 7/ 8 " 4'-5"4'-5"4'-5"4'-5"9'-7"9'-7"9'-7"9'-7"30'-30'-30'-30'-7/8"7/8"7/8"7/8" EXTERIOR WALLS ANDEXTERIOR WALLS ANDEXTERIOR WALLS ANDEXTERIOR WALLS AND ROOF STRUCTURE ROOF STRUCTURE ROOF STRUCTURE ROOF STRUCTURE BYBYBYBY STEEL MANUFACTURERSTEEL MANUFACTURERSTEEL MANUFACTURERSTEEL MANUFACTURER 2X4 WOOD-FRAMED2X4 WOOD-FRAMED2X4 WOOD-FRAMED2X4 WOOD-FRAMED WALLS WITH GYPSONWALLS WITH GYPSONWALLS WITH GYPSONWALLS WITH GYPSON BOARD TYP.BOARD TYP.BOARD TYP.BOARD TYP. U.N.O. U.N.O. U.N.O. U.N.O. 2X6 2X6 2X6 2X6 WOOD-WOOD-WOOD-WOOD- FRAMED WALLFRAMED WALLFRAMED WALLFRAMED WALL OWNER'S OWNER'S OWNER'S OWNER'S OFFICEOFFICEOFFICEOFFICE BATHROOMBATHROOMBATHROOMBATHROOM OWNER'S FLEX ROOMOWNER'S FLEX ROOMOWNER'S FLEX ROOMOWNER'S FLEX ROOM STORAGESTORAGESTORAGESTORAGE OWNER'S OWNER'S OWNER'S OWNER'S OFFICEOFFICEOFFICEOFFICE CONFERENCECONFERENCECONFERENCECONFERENCE HEADERSHEADERSHEADERSHEADERS IDIDIDID H7 PLYPLYPLYPLY 2 SIZESIZESIZESIZE 2X8 SPF NOTENOTENOTENOTE COLUMN SCHEDULECOLUMN SCHEDULECOLUMN SCHEDULECOLUMN SCHEDULE IDIDIDID C2 C7 C9 C12 MATERIALMATERIALMATERIALMATERIAL (4) 2X4 SPF #2 OR BETTER 4X4 SPF #1 OR BETTER 8X8 SPF #1 OR BETTER 3 1/8" X 12" GLULAM 24V-4F 4 SECOND LEVEL WALL FRAMINGSECOND LEVEL WALL FRAMINGSECOND LEVEL WALL FRAMINGSECOND LEVEL WALL FRAMING SCALE: SCALE: SCALE: SCALE: 1/4" = 1'-0"1/4" = 1'-0"1/4" = 1'-0"1/4" = 1'-0" GENERAL FRAMING NOTE:GENERAL FRAMING NOTE:GENERAL FRAMING NOTE:GENERAL FRAMING NOTE: 1. EXTERIOR WALL FRAMING SHALL BE CONVENTIONAL 2x6 FRAMING @ 16" O.C. U.N.O. 2. IF LUMBER GRADING IS NOT SPECIFIED, ASSUME SPF#2 OR BETTER. 3. SEE SHEAR OR BRACE WALL PANEL SCHEDULE FOR WALL SHEATHING AND FASTENING. 4. ENSURE THAT WALLS TALLER THAN 10' HAVE BLOCKING @ PANEL EDGES AND FIRE BLOCKING. 5. ENSURE THAT INTERIOR BEARING WALLS ARE SUPPORTED IN FLOOR BY BLOCKING OR DOUBLE JOISTS. 6. ENSURE THAT COLUMNS INDICATED ON MAIN OR UPPER FLOORS ARE DIRECTLY SUPPORT BY BEAMS OR COLUMNS IN LOWER FLOORS OR SOLID BLOCKING. PROVIDE POSITIVE CONNECTIONS BETWEEN UPPER AND LOWER. 7. INSTALL ALL HANGERS, HOLD DOWNS, TIES, AND ANCHORS & CAPS AS SPECIFIED IN MANUFACTURER DOCUMENTATION. 8. ENSURE THAT WINDOWS & DOORS ARE FLASHED AND SEALED OVER AN APPROVED WALL/ROOFING MEMBRANE TO ENSURE MOISTURE PROTECTION 9. INSTALL SIDING PER MANUFACTURER REQ., INCLUDING RAIN SCREEN OR OTHER. 10. ALL STAIRS SHALL BE CONVENTIONAL IN CONSTRUCTION WITH A MAX RISE OF 7 3/4" AND A MINIMUM RUN OF 10". 11. PROVIDE GUARD RAILS @ 36" FROM NOSING , AND HANDRAILS AT THE SAME. UP W DR 7'-67'-67'-67'-6 1/2"1/2"1/2"1/2"10'-510'-510'-510'-5 1/2"1/2"1/2"1/2"8'-68'-68'-68'-6 1/2"1/2"1/2"1/2"11'-711'-711'-711'-7 1/2"1/2"1/2"1/2" 5'-75'-75'-75'-7 1/2"1/2"1/2"1/2" 9'-79'-79'-79'-7 1/2"1/2"1/2"1/2"7'-77'-77'-77'-7 1/2"1/2"1/2"1/2" 21'-721'-721'-721'-7 1/2"1/2"1/2"1/2" 7' - 1 7' - 1 7' - 1 7' - 1 1/ 2 " 1/ 2 " 1/ 2 " 1/ 2 " 10 ' - 1 0 10 ' - 1 0 10 ' - 1 0 10 ' - 1 0 1/ 2 " 1/ 2 " 1/ 2 " 1/ 2 " 23 ' - 1 1 23 ' - 1 1 23 ' - 1 1 23 ' - 1 1 1/ 2 " 1/ 2 " 1/ 2 " 1/ 2 " 33'-733'-733'-733'-7 1/2"1/2"1/2"1/2" UTILITYUTILITYUTILITYUTILITY BREEZEWAYBREEZEWAYBREEZEWAYBREEZEWAY EMPLOYEE BATHEMPLOYEE BATHEMPLOYEE BATHEMPLOYEE BATH CUSTOMERCUSTOMERCUSTOMERCUSTOMER BATHBATHBATHBATH COOLERCOOLERCOOLERCOOLER STORAGESTORAGESTORAGESTORAGE OFFICEOFFICEOFFICEOFFICE/CONFERENCE/CONFERENCE/CONFERENCE/CONFERENCE ROOMROOMROOMROOM OFFICEOFFICEOFFICEOFFICEOFFICEOFFICEOFFICEOFFICE//// STORAGESTORAGESTORAGESTORAGE WAREHOUSEWAREHOUSEWAREHOUSEWAREHOUSE MERCH.MERCH.MERCH.MERCH. 1 MAIN FLOOR MEPMAIN FLOOR MEPMAIN FLOOR MEPMAIN FLOOR MEP SCALE: SCALE: SCALE: SCALE: 1/4" = 1'-0"1/4" = 1'-0"1/4" = 1'-0"1/4" = 1'-0" MEP DRAWING NOTE: 1. THESE DRAWINGS ARE PROVIDED FOR THE MECHANICAL, ELECTRICAL, AND PLUMBING CONTRACTORS TO MAKE NOTATIONS AND CHANGES ACCORDING TO THE DIRECTION OF THE HOMEOWNER AND GENERAL CONTRACTOR. 2. IT IS THE RESPONSIBILITY OF THE INDIVIDUAL CONTACTORS TO ENSURE THAT ALL TRADE-SPECIFIC DESIGN IS DONE ACCORDING TO THE LATEST CODE STANDARDS AND THE HOME OWNERS PREFERENCE. 3. THE TRADE CONTRACTORS SHALL PRESENT ALL MATERIAL AND FIXTURE SELECTIONS FOR HOME OWNER APPROVAL PRIOR TO PURCHASE AND INSTALLATION. 4. IF THE INSTALLATION OF ANY PIPES, DUCTWORK, WIRES OR OTHER MATERIAL REQUIRE MODIFICATION OF THE SPECIFIED STRUCTURE, THE GENERAL CONTRACTOR SHALL CONTACT THE STRUCTURAL ENGINEER OR DESIGNER TO VERIFY THAT SUCH MODIFICATION WILL NOT NEGATIVELY EFFECT THE STRENGTH OF THE EFFECTED STRUCTURAL ELEMENT. ATTIC/CRAWLSPACE GENERAL NOTE: OPENINGS TO ATTIC AND CRAWLSPACE SHALL COMPLY WITH CODE M1305.1.3 & M1305.1.2 IN THAT ALL APPLIANCES SHALL BE ACCESSIBLE WITHIN 20 FEET OF THE ACCESS OPENINGS. DR A W N B Y : CH K ' D B Y : D. M . #1 - 5 C h e c k e d B y PL O T D A T E : 1/ 1 3 / 2 0 2 2 EN G I N E E R : DE S C R I P T I O N RE V I S I O N D A T E ME P M A R K U P P L A N SH E E T T I T L E : E-101 PLN# 21-10-031 EI T : # 1 - 4 E N G I N E E R I N T E R N RA Y M C D O U G A L , P E 12 7 E . M a i n S t . S u i t e 1 1 1 Re x b u r g , I D 8 3 4 4 0 ww w . s o u t h f o r k d e s i g n . c o m 20 8 - 8 5 2 - 6 2 3 6 So u t h F o r k D e s i g n G r o u p , L L C P R E L I M I N A R Y N O T F O R C O N S T R U C T I O N VE T C L I N I C #1 - 1 C L I E N T A D D R E S S #1 - 2 C L I E N T A D D R E S S Co p y r i g h t 2 0 2 2 | S o u t h f o r k E n g i n e e r i n g | A l l R i g h t s R e s e r v e d . Exit lighting and Exit signs comply with IBC section 1008 and 1013.