Loading...
HomeMy WebLinkAboutPLANS - 05-00224 – 293 Airport Rd - Airplane HangarDRAWING INDEX DRAWING RELEASE HISTORY DRAWING TITLE I PAGES TYPE I DATE I DESCRIPTION MATERIALS GENERAL NOTES ASTM DESIGNATION P BUILDINGS VARCO-PRUDEN Cover Sheet Notes Anchor Bolt Plan Primary Structural Secondary Structural Standard Erection Details VP Buildings, Inc. 3200 Players Club Circle Memphis 3 PLATE WELDED SECTIONS COLD FORMED LIGHT GAGE SHAPES BRACE RODS HOT ROLLED MILL SHAPES HOLLOW STRUCTURAL SECTION (HSS) CLADDING A529, A572, Al011 SS A1011 SS A572 A36, A572, A529, A992 A500 A653, A792 A325 BOLT TIGHTENING REQUIREMENTS GRADE 50 GRADE 55 GRADE 65 GRADE 36 KSI OR GRADE 50 GRADE B GRADE 50 CLASS 2 OR GRADE 80 IT IS THE RESPONSIBILITY OF THE ERECTOR TO INSURE PROPER BOLT TIGHTNESS IN ACCORDANCE WITH APPROPRIATE REGULATIONS. THE FOLLOWING CRITERIA IS IN COMPLIANCE WITH THE LATEST SPECIFICATIONS, HOWEVER THE ERECTOR IS RESPONSIBLE TO VERIFY LOCAL AUTHORITY REQUIREMENTS ALL CONNECTIONS MADE WITH A325 BOLTS MAY BE TIGHTENED TO THE "SNUG TIGHT' CONDITION AS PERMITTED BY THE SPECIFICATION FOR STRUCTURAL JOINTS USING A325 OR A490 BOLTS (2000 ED.), UNLESS INDICATED AS "PRE-TENSIONED"ELSEWHERE IN THESE DRAWINGS, OR AS INDICATED BELOW. PRE -TENSION BOLTS ON PRIMARY FRAMING, BOLTED BRACING, AND STRUT CONNECTIONS IF LOCATED IN SEISMIC PERFORMANCE / DESIGN CATEGORY D, E OR F (ZONE 3 OR 4), SEE CODES AND LOADS NOTES BELOW FOR SEISMIC DESIGN CATEGORY. PRE -TENSION BOLTS ON PRIMARY FRAMING, BOLTED BRACING, STRUTS AND CRANE RUNWAY CONNECTIONS IF BUILDING SUPPORTS A CRANE WITH A CAPACITY GREATER THAN 5 TONS. CONNECTIONS THAT SUPPORT RUNNING MACHINERY AND OTHER SOURCES OF IMPACT OR STRESS REVERSAL MUST BE PRE -TENSIONED, ALL SLIP CRITICAL CONNECTIONS AS INDICATED IN THESE DRAWINGS WITH SC DESIGNATION MUST BE PRE -TENSIONED, SC TYPE CONNECTIONS MUST BE FREE OF PAINT, OIL OR OTHER MATERIALS THAT REDUCE THE FRICTION AT CONTACT SURFACES. ALL A490 BOLTS MUST BE PRE -TENSIONED WITH WASHERS UNDER TURNED ELEMENT. SECONDARY MEMBERS AND FLANGE BRACE CONNECTIONS ARE ALWAYS "SNUG TIGHTENED', EVEN IF ABOVE CONDITIONS EXIST, UNLESS SPECIFICALLY NOTED OTHERWISE ON DETAILS, WASHERS ARE NOT REQUIRED FOR "SNUG-71GHT' CONNECTIONS. PRE -TENSIONED CONNECTIONS TIGHTENED USING THE TURN -OF -THE -NUT METHOD DO NOT REQUIRE WASHERS. CODES AND LOADS WHEN MULTIPLE BUILDINGS ARE INVOLVED, SPECIFIC LOAD FACTORS FOR DIFFERING OCCUPANCIES, BUILDING DIMENSIONS, HEIGHTS, FRAMING SYSTEMS, ROOF SLOPES, ETC„ MAY RESULT IN DIFFERENT LOAD APPLICATION FACTORS THAN INDICATED BELOW, SEE CALCULATIONS FOR FURTHER DETAILS. Building Code: 2003 International Building Code Hanger. Building Use:Standard Occupancy Structure, Collateral Gravity: 1.00 psf (Not Including bldg wt) LIVE LOADS AND RAINFALL Live Load 20.00 psf (Reducible) Rainfall: 4.00 in per hour SNOW LOAD Ground Snow: 50.00 , Roof Snow: 35.00 psf, Flat Roof Snow: 35.00 psf Snow Exposure Category: 2 Partially Exposed Snow Importance: 1.000 Thermal Category (Factor): Heated (1,00) WIND LOAD Wind Speed: 90.00 mph, Wind Exposure: C Basle Wind Pressure: 15.36 psf Wind Importance Factor. 1.000, Ft= Topographic Factor. 1,0000 Wind Enclosure: Enclosed, 0,160 Note: Ifthe building Is design as ENCLOSED, all windows, doors, skylights and other covered openings must be designed for the specified above wind loads EARTHQUAKE DESIGN DATA Lateral Force Resisting Systems using Equivalent Force Procedure Mapped Spectral Response - Ss:51.08 %g, S1:16.44 %g Seismic Hazard I Use Group: Group 1 Seismic Performance / Design Category: D (See Bolt Tightening Note Above) Seismic Snow Load: 7.00 psf Seismic Importance: 1.000 Soil Profile Type: Stiff soil (D, 4) Design Spectral Response - Sds: 0.4738, Shc: 0.2348 Ordinary Steel Moment Frames Frame Redundancy Factor.1.2000 Framing R-Factor. 3,5000, Frame Seismic Factor (Cs): 0.1354, Design Base Shear = 0.1354 IN Ordinary Steel Concentric Braced Frames Brace Redundancy Factor.1.2000 Bracing R-Factor. 3.5000, Brace Seismic Factor (Cs): 0.1354, Design Base Shear= 0,1354 W THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP 7gSDRAWNG NCLUDING ENFORMATONHEREON. P�OPER COVER SHEET AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE Ilj REMA NS HE OF VP BUILDINGS. IT IS PROyIDED SOLELYFo R ERECTN GTHE BULDINO t^U"",,.wA4o BUILDER JOB N VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN DESCRIBEDNTHE APPUCA&TEPURCHASEORDERAN0 FOR Teton West OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO SHALL NOT BE MODIFIED, REPRODUCED OR USED ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN CUSTOMER DATE ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. APPROVAL OF VP BUILDINGS. 5/12I2005 THE 0 ENERAL CONTRACTOR ANDIOR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE, GOOD QUALITY WORXMANSMP LOCATION Rexburg, Idaho . VP BUILDINGS DRAWN/CHECK N ERECTING THIS BUILDING IIINNCCONFORMANCE WITH THIS ARL APPLIC AF11VP8UNE.DINGS EREC auDRAWWING VP BUILDINGS, INC. PROJECT Nile Tanner AND INDUSTRY STANDARDS PERTAINING TO PROPER RISC CATG. NB CERTIFIED ea DERSPOR VPCVERSWN. 5,2b PAGE ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. 5/17/2005 11:44:37 FILE"' 4091 Nile Tanner 50x50x17 5-12-05.VPC i iv .I rro' rYn,NR I—, ] IN, x [MN wA is"If w sun¢n AN1 Mno[onu NU yPLI wIN oo MaxU, vP r y ,Y u x Av0 w°[A �_ u°t. xlp 14N¢kR VN UNIMPN AL NIf OLD. ]" 'MN• GCL w' ci'w urv3TPU[5 (NI 1/9'AAM DOLTSVIII C WK, WAOHR ^ IN w BIRAgIr+ -fir p fARU[U N[MwR 4 .xr+ruxelf LANRI Nu[ L4r R[W C Na[ �PRgxl[R NANgP SKI[x xUn D/19" Y YN. a• xe * tic UwWxY Ai ,e1N[ x2B C Pr Rp31nxA: Y< Lf1 4 KEM Or wiLR rLlCb RBx P[v 1. , CeN[Npl�+kfw 91DLR , fGY 1NN A! P1ntR SutKUKo L¢M4 evC[[NxD u x _ rWq[ BNAR R(gxA[WnL, GCI•e LLUSE Of ]Uv[x%D I.D. 1D 5XR w u I w ¢BYPUNiAS. ®[ K[nD VXtt s w wur n.w. rP eMlPx RwLLf. cDNrRAc1DWs Nm[I 1 M C8 :"I I- ILL rLwO[ N SIN VN OPG 9111 * u F e Ix41ALLE ono Oxll n exLO 0. N 99 u [ B P ALLOwILC lOW Nro NQ Min Of wljS[9 W[ 1- 91NUlE ties¢! &4PLC9 ML IKOUIRCU WNLN PNrI NAxx 011 [ I Miry PLR x,I U w[lG wnxoln IxfP[n10u ROSD S[CIWN a Nlil At OwNIHO NY It COMPAI'TN('S NET': AM' LVA06 WR A,il WS. APRKO 10 w u[uBUi I I C • le XW9 HP wCH lY Km NTx IN9%[+MN RUK 3- L w ° S AA iN TH tR fYCx w xVAc, IRMIW, WMxO IY unD L1C, KFI I[ u+BPNLv I I E wri+CN 0 C MOVWLD W S Uf [ ALC W[B P "^' Aptlb PN N„DI IOL16 OP IubR.6 W KLD i¢ cCle, ULP@ K —III-IDvN. Br l�. M� w0 10 IYUH VARI-ulYu0N0' LPI[xAlfLOAo w4+AxxR LLLYLMI (IN I, OAUf 1pyR +uax DW LN xAr Bk eLnKxIXO RUl[IA- WnN(.uLp CN gIHT3, I&CEliwQACL SLN4l[ .C9 10WAvb INC I 6LY AR R¢aAlrz¢ [rr cm[ U11N9 CIAMr9, (1 IfY" F.N LODE Or PUNKI. 11,, All I. °lISK l4ADB BWCN¢ uU91 % P9DNP[p wD w1,Kl[0 M CM,NKICR pNCWYMSLG LDAok 41NL1 Mt CNC[E0 L1U Ca DNCO LCLU+[ML C IULtfl- e10[wW iHEIPIAL°a[ W—f Al I Ut a IE ON 11 Lwl 1.LNI IM 6 MNO IKP fn COOL. wOiuCHYNDIr1. lL 9N1 w 111 w9PL.0 LDIOIMO INgCA1L0 (N1 Ml INRCNA% OPDIR AI'L IN w CAIr.VU1NNd9, )D GABLE BRACING AT COL. BASE BRa2A1 _TYPICAL FLANGE BRACE CONNECTIONS BR06BD SUSPENDED LOADS EN1 Al SUSPENDED LOADS EN70A2 STANDARD SHIM PF PLATE OR OAGC x ,dn•Yn Yx Wm lxnN «ANw wIx .A+.• FROM PURLINS - 100 I.B. LOADS OR CREAIER FROM STRUCTURAL BEAMS TYPICAL AT ANY BOLTED CC KN[3 O NAWe+ te'Cul1, (wl/KKA'tYL MASK L �x-YR r)/B" ROpf Ax vNl PinK 1 ITAN11 MILT/P , C" P.o. (- IIAHxI r - rx/mltR ti A•rvL xux xn. I [ —COOIN Y NRLN rsNq N�[. YNup�O[[C[ OrLA WLnUN �/R-I r)/°' MiM ^ANIMA • wP (TP-fn]0'A I I �" /le' r I +rIC w91x. GVM. (BO�RPI P Y l 4IB-CANIIAW 0[AO I[Ax 0 [ IIr[N 110[NIY M WTIN1 Or Aror M rob IWD rAst w. [ 9 c [ r r /,, RRn n m.N.( Rwvt uuA nV„ (CO�v 0 N c c I �r- �- ]/le' . 011e ItW xx up( IAA - IL rxl/e• RGY [NDLAP h RIDGE CAP i -#/�--------- wL w51" 1 cUM, Ib]w) j PER 9wCt YOB �� 1'�LR r3YUwLLN6R10T) (1 IN w➢, [vmr[101�x1 r ly-I. r I I/[• PDt1Y r1MY • F 1/I' llR SipIM I.Nx•u[ 1\ «� IYR� Mr4C 11 Ufi t t!) ORI v l InB (II BW IDDI HL MB � INKIx eWIW f00[/••I[ ° Rn •� IMERUEOIATC S111CN IHM PUALIN I aq{{ . RMw ton er4C. WDYOK^ D' BI [NSI% nouw[ v([Lma I�ew'1 DI fiAVCI r9xP/x POW S[f ICa Ym Rnn[Rx AI W4[W MCM[D NNLL 9PI W4L 14V[L S1RIA`I rfw AMK MAxHI LOVRR 9[F r(M UL90 vAY1FRx ] RU TOM O'41l' u°oc1� Dq L-- • L I/,v Lan P(qf N "FL XOfIA• BUILLIING [AVE - I__� I III10 P[...M N(M S[[ � ftR ICE CAYNxLC N114Px PANEL RIB ROOF & WALL PANELS PR EN6 Al PANEL RI ROOF RC03B1 PANIL SI[XLAP LAYc ruRNx IlVlylll}�'�( 1—St-- WALL LLIIU NALN�N 1'.. R'UC1 END UfLiNI mIt N[x%n Pot[ IN Iwro uR LDI+1[Mla I,E BlKP�01R[.. rx my[x �x, e,L:w„rr SECTION A -A 12-Ix I I VO NFL HAUNT x PDR rtlm— '^[[uo' [fYN[F LYMA/K LL 4aYl PANEL RIB ROOF RAKE TRIM RC30B1 PANEL RIB ROOF AlL y URLINS AT OR q VA WALL TNRU 2:12 NOTCHED PANEL RIB WALL w1r, 1191 To, EI R AT IHI AtlRI V4N WALL m{[ u[u N rwSILNYI nnrc'r COxCv[1C[NM[n[A,Y,1 ] P[p tWl Rwll NDIYW I ex, In'.1 ev W r:r files' B �OR I In' �I p ONfJDUMt-•� '�` 1 AYNI mx ttP 1`{ 1 p Rp DIL', I I I NYL nAKKr "DID, Bfw .IN IALN M[l0) CNlDIM[ 19N I/]• IMM w YJJ � -p W[ xCNMA NOTION A -A DAS JAMB BASE ATTACHMENT 6 I/2' DR B 112' JAMS I VS- NULL M Y I� I I I II II SECTION A -A PROPOSED GIRT TO JAMB CONN. W B 1/2" GIRT. B 112" ANTS THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORE PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PER- FORMANCE REQUIREMENTS SPECIFIED BY VP. Ps' Ix[+AD[ ONB �•�-•I ,.1,,, ro r',I° {ip'J.. b�-11 N l rtx r[Lc fR¢t CDwllw KKD YLCI 'SHOP SPLICE OEiAILS• r = fF[I D + O/qC ° INLHS D • oruATlu1 [ • [IbMMf L • r1 WLRU PANLLXCDI[PI roB I I] 1 v Y 1 I [ ¢ 0 D t c c r L j jN C'CTEF INSLLx+ILN [cxrr • to wl rmxr[Y Kxrry ° D[+ r s Ctl[IPx .rO+NLu R1N••r • PAfi[R IRAttf wR••• • RMTLR t1111 LWM.r • WIED tNCIMLl 1RM•r. • IWtB RPf1[P Wr. .rh L I] 0 I D] L I I I, v 1 ILx.rr . IM[R)DR CDLUM Rcx.r. • PUL tlLwx �Gi^Wu1H � v. r r 1 1 1 1 r I L L L CtlniH tii6'ix�2d6L rcx..r.IwL tDLulx 1HR N 6[LDYBAPY I9TANDMOf DID 1 9 1 1 (I [P}•vr [NOPCSI IPLMLY L4x••r . LNOMSI ItAffl 11 MI LCNpS w r r [f F _!p l[uDTN CON a L¢[[Ixr. ,µP vSwIRN1[+ Y etl�[I r• I 0 [DaDAPY YLK;INY 01A 1+ PeLlx� 11 WVBPG GHOPv Y v+tll [LL LTh4rN CE3 M+SIL%U OlM[NSIdVS 1b 10 I,[b IRA[w: ACxi[K amm P[aLLrf ,,, A° u I D] R A a 1 1 D WY9 ARC MADE pg p�7 I[ r v i f i 1 .Wlf" NA+DIAL' THREAD LufH Fri CnorN PANEL RIB ROOF RC34B1 RIDGE CAP,ENDLAP I • (YA) NMr Ix IyYR \ I mnt o ( ) I I 'UxumIRAC[ I LL,L4F BNNCC Its 1 pe-) II uYWL9 chit e C011N9[ era01] I[[ GP+ fxoAN C[[ pM NNILM ' r[[ oPr I.D. ;IR7 CONN. AT COLUMN INS014 GIRT CONN. AT COI. 112. 6 B 1/2" OUTSET SIMPLE GIRLS B 1/2" INSET DIMS UCW�]H[.FN I1] ti.Y.i%yyP I EMP B 1/2" BASE GIRT REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBEDINTHE APPLICABLE PURCHASE ORDER AND ANV OTHER PIEIRPOSEEWIYHCUT PRIOREMR UNEO FOR APPROVAL OF VP BUILDINOS, T'fE THE GENERAL CONTRACTOR ANOIOR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE, GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN COpoPFr ORMANCE W TH THIS ALLLA�LICDABLE VPREREC ON GLIDESIS DRAWING, AND IfNOUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING, IPI AWNY '�A eMA%D ARG� AIUC�pMAI unr BE 41loiN I ��]+f1u' I. wNYE �L" ­1 '1 l¢G Q COLUMN EIR RC 1wA07 urittn nle cv �npa AB w (IrecJ A9f[uwr SA+1•ACX w/ e AOP RN[+9 RAn IAf['IA ���yyy rtAeAJAiND[x 7J1 pTaw Iv°• 4 .111)tif R/ � c[5pL ICAY—� AR (uc•1 I T I , T Y GAGE LENCTN AT A PAT RL•t1-1U. 90•I' [ND Mr, I' •b LAP 1 LR•YIWI1 I'1 "IAY Il•I' [ND IAv, 1'•L' LAR oTtl Mlt L' MY 11•I' END I, I' •V LAR DI•CMI X6[ -11 5+1' END, I., 8' -/' LN LS+IN[CI MI[N L•I' [XD IAV, y-U lAP ➢IHA HELL, ]I•I' [ND IAY, 1 -1' LAP [o 'END IAY. 1'•01 LAR 41.Ill 11•' [NB 1- 1'-1' LAP@- ' [ND IIr, ' LAP AL-IMIUIp MY, 1'-Y LM EI•lV ' [NB IAY, d'-L• LM M-IMCR)[M mY, I'-U I. •IM[LAn Ull 4w• [xtl MI. a'-' Lv IDwlm y`, -[• Sl•R' LAP D MI, S' Y•IN+[RIM ]-a Lw L4' END MY. ('-p LAP AO•IHI[RIDP MY, Y•V AL•IN+[PLOP MY, 4'-C' LN° 'wI( f w SSL Sll ML'[b xplm SCIA RC38C5 PURLIN CONN. AT INTERIOR CAP ATTACHMENT (P-RIB ROOF) I I B 1/2" OR B 1/2' CONTINUOUS PURLINS M1'[ • KIkM OIn 1616 1 r10.Rtl Pm [LP I ,];p BI oNvlE 1\ PAH wAN UA, 'tt �9 ILE, rMiiB 4'LL lM PAtf "1 ixfA[IJ ^11 n ILri91ni Y Y CC IMtl}I ° B/]' DIMf F • !' Y ! E IIF41[ E Mi fug-1 GABLE GIRT CONN, TO RAKE BEAM WSO4Dl GIRT CONN. AT CORNER COLUMN W510 2 GIRT CONN, Al B 1/2- INSET GlRi3 B 1/2' INSE7 GNNT Ai EW, ANY OVFSC7 GIRT AT BW ANY oUs GIRL Al un 1 BYO i)I°D17 LLD WITH M% DI11 (( 1 p MW NLUAW m% D a Ly 4[I 0 !NER COLUMN V ASE GIRT 11T o) NFL.. .Lcm I ) /ir' wnrxsLl �f11Uta OyM'/R r0.L[Y u (IA-1 wr VP Buildings, Inc. 3200 Players Club Circle Memphis TN 38125 BUILDING SEDIS EV DATE BY DESCRIPTION BUILDER Teton West CUSTOMER LOCATION Rexburg, Idaho ROLEcr VP BUILDINGS Nile Tanner RALOfi B NTS rUJLDIPON VPCVERSION, 5,2b 5/1712005 11:45:04 FILENAME 4091 Nile Tanner 50x50x175-12-05.VPC Covering Schedule Id Qty Type Length Gage OP Fin #121 17 PR 16' -3 7/8" 26 G K #122 1 PR 1' -2 1/2" 26 B K Oper. Code: G=CR,NIT Oper. Code:B=SQ,CR Finish: K=KXL Color: TD=Standard Color 0 Color Direction TD Right to Left TD Right to Left Trim Schedule Id Parts T1 (2.5)BG3 Color Details Match Wall Color EN52A1,WCO1D1,WC04A1,WS27A2,WS27C2 T ------ i i I I I I I i i I I I I I I i I I I I I I I I i II i i I i I I i ---------- --------- --------- --------- --------- ---------- --------- --------- (17)#121 T1 --------- --------- ---------- --------- --------- --------- --------- ---------- e NBVP - Maso y 1. WALL SHEETS ARE AN INTEGRAL PART OF THE STRUCTURAL SYSTEM, THE VP ENGINEER'S SEAL APPLIES REMOVAL OR ALTERATION WITHOUT PRIOR AUTHORIZATION IS PROHIBITED. VPNAND TO THE PERFOCRMANCE 2 SEE JOB DETAILS FOR SHEETING AND TRIM FASTENER SPECIFICATION. REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES 3, PRE -DRILLING 1/8 DIAMETER HOLES FOR WALL STRUCTURAL FASTENERS NOT APPLY TO THE PERFORMANCE MAY BE REQUIRED AT 11 GAGE GIRTS, NESTED GIRTS, GIRT LAP OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP LOCATIONS, AND/OR SECONDARY STRUCTURAL BEAMS EXCEPT TO ANY DESIGN OR PER- FORMANCE REQUIREMENTS SPECIFIED BY VP. 0'-0" COVERING ELEVATION AT M = Hanger. Wall = 4 THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLEPURCHASEORDER AND SHALL NY OTHER PEURPPSE WItHOUT PpIOR WgtnENED FOR APPROVAL OF VP BUILDINGS, THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE, GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN CONFORMANCE WITH THIS RAPLCDBLE REFERENCED S DRAWNG, ALL APIAVP RCTIOGUIDES, AND INDUSTRY STANDARDS PERTAINNGTOPROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING, VP Buildings, Inc. 3200 Players Club Circle Memphis TN 38125 '.EV DATE BY DESCRIPTION NTS 5/1712005 11:44:59 COVERING ELEVATION AT M ALDER Teton West JSTOMER CATION Rexburg, Idaho IOJECT Nile Tanner 4091 Nile Tanner 50x50x17 5-12-05.VPC DATE 5112/2005 VP BUILDINGS DRAwwcHECK VWCORiUOEN VPC VERSION. 5,211D PAGE Covering Schedule Id Qty Type Length #94 9 PR 17 1 -10 1/211 9 PR 17 1 -10 1/211 I#95 #96 1 PR 11-2 1/211 Oper. Code: F-CR,SQ Oper. Code: B=SQ,CR Finish: K=KXL Color: TD=Standard Color 0 Gage OP Fin, Color Direction 26 F K TD Left to Right From Peak 26 F K TD Right to Left From Peak 26 B K TD Right to Left From Peak 1. WALL SHEETS ARE AN INTEGRAL PART OF THE STRUCTURAL SYSTEM, REMOVAL OR ALTERATION WITHOUT PRIOR AUTHORIZATION IS PROHIBITED, 2. SEE JOB DETAILS FOR SHEETING AND TRIM FASTENER SPECIFICATION. 3. PRE -DRILLING 1/8 DIAMETER HOLES FOR WALL STRUCTURAL FASTENERS MAY BE REQUIRED AT 11 GAGE GIRTS, NESTED GIRTS, GIRT LAP LOCATIONS, AND/OR SECONDARY STRUCTURAL BEAMS THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PER- FORMANCE REQUIREMENTS SPECIFIED BY VP. Trim Schedule Id Parts TI(3)RCHBI5,RCHB10,(6)RFR10,(2)RKF20,RKF16 T2 CT16 T3 (2.5)BG2 T4 EAIL,PRF1 01-011 COVERING ELEVATION AT 3 = Hanoer. Wall = 3 REMAINS THE PROPERTY OF VP BUILDINGS, IT JS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND ANY OTHER PURPOSE WIiNOIPJRT PRIOp WRfIRTENED FOR APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE, GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN CONFORMANCE WITH THIS DRAWNG, DETAILS REr CRENCED IN THIS DRAWING, ALL APPLICABLE VP ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. VP Buildings, Inc. 3200 Players Club Circle Memphis TN 38125 EV DATE BY DESCRIPTION NITS 5/17/2005 11:44:58 Color Details Patrician Bronze RC30B1 Match Wall Color WC20A1 Match Wall Color EN52A1,WCO1D1,WC04A1,WS27A2,WS27C2 Patrician Bronze RC38A2 T COVERING ELEVATION AT 3 1ILOER Teton West JSTOMER 'CATION Rexburg, Idaho tOJECT Anfl Nile Tanner ALDER'S PON VPC VERSION 5.2b .ENAMEI 4091 Nile Tanner50x50x17 5-12-05.VPC JOB N 1 5/12/2005 Covering Schedule Id Qty Type Length Gage OP Fin #119 17 PR 16' -3 7/811 26 G K #120 1 PR 1'-2 1/2" 26 B K Oper. Code: G=CR,NT Oper. Code: B=SQ,CR Finish:K=KXL Color:TD=Standard Color T T3 Color Direction TD Right to Left TD Right to Left Trim Schedule Id Parts T1 CT16 T2 (2.5)BG3 T3 EAIR,PRF1 Color Details Match Wall Color WC20A1 Match Wall Color EN52A1,WCO1D1,WC04A1,WS27A2,WS27C2 Patrician Bronze RC38A2 T I I I I I I I I I ---------- --------- ---- --------- ------------ -------- --------- --------- I II I I I I I I (17)#119 I I �I EI I I I II I I I II I I I I T2 #120 0 Z Z .I NBVP - Maso y 1, WALL SHEETS ARE AN INTEGRAL PART OF THE STRUCTURAL SYSTEM, THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF REMOVAL OR ALTERATION WITHOUT PRIOR AUTHORIZATION IS PROHIBITED, VP AND DESIGN AND PERFORMANCE 2 SEE JOB DETAILS FOR SHEETING AND TRIM FASTENER SPECIFICATION. REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES 3 PRE -DRILLING 1/8 DIAMETER HOLES FOR WALL STRUCTURAL FASTENERS NOT APPLY TO THE PERFORMANCE MAY BE REQUIRED AT 11 GAGE GIRTS, NESTED GIRTS, GIRT LAP OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP LOCATIONS, AND/OR SECONDARY STRUCTURAL BEAMS EXCEPT TO ANY DESIGN OR PER- FORMANCE REQUIREMENTS SPECIFIED BY VP. 0'-On COVERING ELEVATION AT A = Hanger, Wall = 2 THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND ANY OTHER PURPOSFE WIYHOUT PRIOR WRITTENED FOR APPROVAL OF VP BUILD;NGS THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE, GOOD QUALITY WORKMANSHIP N ERECTING THIS BUILDING IN CONFORMANCE WTH THIS ALL APPGe�BLEVPE0.ECENCOD� SIS DRAWING, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING VP Buildings, Inc. 3200 Players Club Circle Memphis TN 38125 EVI DATE I By I DESCRIPTION NTS 5/17/2005 11:44:57 COVERING ELEVATION AT A ALDER Teton West ISTOMER CATION Rexburg, Idaho OJECT Nile Tanner ALDER'S POM ENAMEI 4091 Nile Tanner 50x50x17 5-12-05.VPC P BUILDINGS WALOPAUDBV VPCVERSION 5.21D JOB k 1 5/12/2005 Covering Schedule Id Q ty Type Length #87 7 PR 181-10 1/21, #88 2 PR 16'-1 1/211 #89 7 PR 18'-10 1/21, #90 1 PR 16'-1 1/211 #91 1 PR 16'-811 Oper. Code:F=CR,SQ Oper. Code: 1=SQ,SQ Finish: K=KXL Color:TD=Standar A> or Gage OP Fin. Color Direction 26 F K TD Left to Right From Peak 26 F K TD Left to Right From Peak 26 F K TD Right to Left From Peak 26 F K TD Right to Left From Peak 26 1 K TD Right to Left From Peak Trim Schedule Id Parts T1(3)RCHBI5,RCHB10,(6)RFR10,(2)RKF20,RKF16 T2 CT16 T3 (2.5)BG2 T4 RRCI0,SPC10 T5 EAIR,PRF1 T6 EAIL,PRF1 T4 ----------------------- Color Details Patrician Bronze RC30B1 Match Wall Color WC20A1 Match Wall Color EN52A1,WCO1D1,WC04A1,WS27A2,WS27C2 Patrician Bronze RC38C4 Patrician Bronze RC38A2 Patrician Bronze RC38A2 T1-25'-1 1/1O _---- ------------- --__ __------ — T1-25'-1 - T6_— ----- ---- -- ---------------- -- ------- I I I I I I I I --- ------ T5 I I I I I I I I I I I I e N C c e i IN I I I e 0 0 F r F OJ m m W m m cc O r r- t` 'i 'i #90 #91j I #89 (2) #88 I I (7) (7) #87 N I Ei l N I iEl I I I I I I I I j j I I I I I I I T3-5' —011 I I I I I I I o T3-5'-0" I rBVI- Maso 1' T3-40'-0° e BVFI Maso y COVERING ELEVATION AT 1 VP Ref: Shape Name anger, Wall = 1 1. WALL SHEETS ARE AN INTEGRAL PART OF THE STRUCTURAL SYSTEM, THE VP ENGINEER'S SEAL APPLIES THIS ORAVANG, INCLUDING THE INFORMATION HEREON, REMOVAL ORAUERATIONWITHOUTPRIORAUTHORIZATIONISPROHIBITED. ONLY TO THE WORE PRODUCT OF REMAINS THE PROPERTY OF VP BUILDINGS. 2 SEE JOB DETAILS FOR SHEETING AND TRIM FASTENER SPECIFICATION. VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED INTHE APPLICABLE PURCHASE ORDER AND 3. PRE -DRILLING 1/8 DIAMETER HOLES FOR WALL STRUCTURAL FASTENERS THE VP ENGINEER'S SEAL DOES SHA NOT ggEMODIFIED REPRODUCED OR USED FOR ANV OTHER PURPOSEWIYAPT PRIOR WRITTEN MAYBE REQUIRED AT 11 GAGE GIRTS, NESTED GIRTS, GIRT LAP NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT APPROVAL OF VP BUILDINGSOR THE, CONTRACTOR AND/OR ERECTOR IS SOLELY RESPOENSIBLEF RACCURATE,GOODQUALTYWORKMANSHIP LOCATIONS, AND/OR SECONDARY STRUCTURAL BEAMS NT VP EXCEPTPTOEANYFDESIGNEORBPER- FORMANCE REQUIREMENTS IN ERECTING THIS BUILDING IN CONFORMANCE WITH THIS SPECIFIED BY VP. ALL APPLI ABLE VPREREC ON GUUIDES, DRAWING AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. VP Bulldings, Inc. 3200 Players Club Circle Mernphls TN 38125 COVERING ELEVATION AT 1 REV DATE I BY I DESCRIPTION BUILDER Teton West CUSTOMER LOCATION Rexburg, Idaho PROJEcT Nile Tanner NTS BUILDER'S POOR 5/17/2005 11:44:56 FILENAME4091 Nile Tanner 50x5Oxl 7 5-12-05.VPC P BUILDINGS wacoaauoSu VPC VERSION'. 5.2b JOB N 1 5/12/2005 Covering Schedule Id Qty Type Length #80 17 PR 24'-5 3/8" #81 17 PR 3'-4" #82 17 PR 24'-5 3/8" Oper. Code: 1=SQ,SQ Oper. Code: 3=SQ,SQ Finish:G=Galvalume Color:TD=Standard Color Gage OP Fin. Color 26 1 G TD 26 3 G TD 26 1 G TD 0 I 0 Ice Damming Conditions Exist - (Field Repair Fastener) (1 bags) #55308 #17-14xl" S.S. Roof Fastener Notes 1. PRE -DRILLING 1/8 DIAMETER HOLES FOR ROOF STRUCTURAL FASTENERS MAY BE REQUIRED AT 11 GAGE PURLINS, NESTED PURLINS, PURLIN LAP LOCATIONS, AND/OR SECONDARY STRUCTURAL BEAMS 2. ROOF SHEETS ARE AN INTEGRAL PART OF THE STRUCTURAL SYSTEM, REMOVAL OR ALTERA110N WITHOUT PRIOR AUTHORIZATION IS PROHIBITED. 3. SEE JOB DETAILS FOR SHEETING AND TRIM FASTENER SPECIFICATION. 4. FOR PR PANEL, PRE -DRILLING OF SIDELAP FASTENERS REQUIRED DUE TO THE ABSENCE OF A PURLIN BEARING EDGE. SEE SED RC03B1. Direction Left to Right Left to Right Righ 1 o Left Trim Schedule Id Parts T1 RRC10,SPC10 (17)#8 (17) #8 (17)#8 1 50'-0" THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PER- FORMANCE REQUIREMENTS SPECIFIED BY VP. ROOF COVERING PLAN IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND SHALLNOTBEMODIFIED REPRODUCED OR USED FOR ANY OTHERR 7PURPOSE W7YHOUT PRIOR WRRTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE, GOOD OUALITY WORKMANSHIP IN ERECTINGTHISBUILDING IN CONFORMANCE WITH THIS ALL APP�ICDABLE VP ERECTION GUUIDES IS DRAWING, ANDINDUSTRY STANDARDS PERTANNG TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING, Color Details Patrician Bronze RC38C4 VP Buildings, Inc. 3200 Players Club Circle Memphis TN 38125 IEVI DATE BY DESCRIPTION NTS 5/17/2005 11:44:53 ROOF COVERING PLAN OLDER Teton West STOMER CATION Rexburg, Idaho DJECT Nile Tanner ILDER'S PGM ENAMEI 4091 Nile Tanner 50x50xl7 5-12-05.VPC P BUILDINGS voRcoaBuoen VPC VERSION; 5 2b JOB M 1 5/12/2005 II I I I j I f f ---- --------- —---------- —-------------------------------------------- 01, —. I I I I I I I I I I I I I I I I I I I I I I I I I t I I 29GI I 02K2411417(Typ.) �q4� 03K2411417(Typ.) I I I NBVP -�; o y /-7-1 I I 4 1' -1 1/4" 3 2' -10 3/411 2 6" 1 1'-0" Dimension Key 1. UNLESS NOTED, USE 112 X 1 1 /2 A-325 SNUG TIGHTENED BOLTS FOR GIRT LAP, GIRT TO FRAME, FLANGE BRACE TO FRAME, FLANGE BRACE TO GIRT, JAMB AND HEADER CONNECTIONS. 2. WIND AND FLANGE BRACING ARE AN INTEGRAL PART OF THE WALL STRUCTURAL SYSTEM AND SHOULD BE PROPERLY INSTALLED PRIOR TO EREC71ON OF WALL AND ROOF SHEETS, REMOVAL OR ALTERATION OF WALL BRACING WITHOUT PRIOR AUTHORIZATION IS PROHIBITED. 4'-01, THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORE PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PER- FORMANCE REQUIREMENTS SPECIFIED BY VP. 0'-0" SECONDARY ELEVATION AT M VP Ref: Shane Name = HannAr Wall = IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBEDINTHE APPLICABLE PURCHASE ORDER AND ANY OTHER PURPOSEEWITHOUT PftIOREDOR UNED FOR APPROVAL OF VP BUILDINGS. fITE THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE, G00D QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN CONFORMANCE VrifN THIS DRAWING DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP R C ON GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. 4' -611 VP Buildings, Inc. 3200 Players Club Circle Memphis TN 38125 SECONDARY ELEVATION AT M REV DATE BY DESCRIPTION BUILDER Teton West CUSTOMER LOCATION Rexburg, Idaho ROJECT Nile Tanner NITS BuiLDERs- 5/17/2005 11:44:52 FaENAME 4091 Nile Tanner 50x50x175-12-05.VPC P BUILDINGS NNC6PRUOBI VPC VERSION: 5.2b OPart Mark Key 1 JBC1 2 004JO702017 3 01G0302217 4 GFA206 0 uo w 0 3'-6" 3'-0" 0'-0" SECONDARY ELEVATION AT 3 2 3' —2 1/4" 1 4'-0" Dimension Key VP Ref: Shape Name = Hanaer, Wall = 3 13'-6" O O 1. UNLESS NOTED, USE 1/2X 1 1/2 A-325 SNUG TIGHTENED BOLTS FOR GIRT LAP, GIRT TO FRAME, FLANGE BRACE TO FRAME, FLANGE BRACE TO GIRT, JAMB AND HEADER CONNECTIONS, 2. WIND AND FLANGE BRACING ARE AN INTEGRAL PART OF THE WALL STRUCTURAL SYSTEM AND SHOULD BE PROPERLY INSTALLED PRIOR TO ERECTION OF WALL AND ROOF SHEETS, REMOVAL OR ALTERATION OF WALL BRACING WITHOUT PRIOR AUTHORIZATION IS PROHIBITED. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUTAEMENTs SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT Or, COMPONENT FURNISHED BY VP EXCEPT mo ANY DESIGN OR PER- FOR14ANCE REQUIREMENTS SPECIFIED BY VP. THIS DRAVANG,INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OFVPBUILDINGS. ITS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED INTHE APPU APPLICABLE SHALL NOT BE MODIFIIEDREPRODUCEO OR USED FOR ANYOTHER OF VP BUILD NHOUT PRIOR WW EN APPROVAL OF VP BUILDINGS VP Buildings, Inc, 3200 PaersClubClrcle Mem Y phIsTN38125 EVATIONAT3 REV DATE BY DESCRIPTION BUILDER Teton West CUSTOMER LOCATION Rexburg, Idaho g PROJECTNile Tanner �&n JOBN THE GENERAL FOR ACCURATE, 000 ERECTOR ORKM N RESPONSIBLE FORAccuRATE,GoocQUALITY woaKMANSHIP INERECTING EETHIS BUILDING INCONFORMANCE WITH THIS ALL RPPLICABLELVP ERECTION GUUIDES, DRAWING, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. DATE 5/12/2005 DRAWMCHECK NTS BUILDER'S PON VPC VERSION: 5.2b PAGE 5/17/2005 11:44:51 FILENAME 4091 Nile Tanner 50x50x1 7 5-12-05.VPC T - - - - - - - - - - - - - - - i ------------------------------------------------------------------------------------- i I I I II I Og �9 I I I I I I I � I I I I I I I I II I I I I I I I l I II I I I I I I I I I I I I I I I 03K2411417(Typ.) I I I I 02K2411417(Typ.) I I I I I I I 77-- zNBV4-M. y 7D 4 1' -1 1/4" 3 2' -10 3/4" 2 1'-01' 1 6" Dimension Key 1. UNLESS NOTED, USE 1/2 X 1 1/2 A-325 SNUG TIGHTENED BOLTS FOR GIRT LAP, GIRT TO FRAME, FLANGE BRACE TO FRAME, FLANGE BRACE TO GIRT, JAMB AND HEADER CONNECTIONS, 2, WIND AND FLANGE BRACING ARE AN INTEGRAL PART OF THE WALL STRUCTURAL SYSTEM AND SHOULD BE PROPERLY INSTALLED PRIOR TO ERECTION OF WALL AND ROOF SHEETS, REMOVAL OR ALTERATION OF WALL BRACING WITHOUT PRIOR AUTHORIZATION IS PROHIBITED. 4'-6" THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PER- FORMANCE REQUIREMENTS SPECIFIED BY VP. 0'-0° SECONDARY ELEVATION AT A = Hanaer. Wall = 2 IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND ANY OTHER PVAPOSEI W14HOUT PRL."NII IT AED FOR APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE, GOOD OUAIRY WORKMANSHIP IN ERECTING THIS BUILDING IN CONFORMANCE WITH THIS ALLLAAPPLItABLAEVPRERECTnONGUIDESL DRAWING, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. 4'-0" VP Buildings, Inc 3200 Players Club Circle Memphis TN 38125 SECONDARY ELEVATION AT A REV DATE BY DESCRIPTION BUILDER Teton West CUSTOMER LOCATION Rexburg, Idaho ROJECT Nile Tanner NTS BUILDERS PON 5/17/2005 11:44:50 FLENAME 4D91 Nile Tanner 50x50x175-12-05.VPC VP BUILDINGS KACOPFUOB! VPC VERSION. 5.2b JOB N 1 5/12/2005 OPart Mark Key 1 JBC1 2 001J0702217 3 DJC1 4 01G0408417(Typ.) 5 OIC0408417 6 7 DH0608717 8 01G0608717 A M 9 DHO608617 10 01G0608617 11 DHO609017 12 01G0609017 c 0 w C 3 1111 2 3'-2 1/4" 1 4'-0" Dimension Key '-0" 3 3 5'-0" -6 5/16" 6'-9 3/8" 6'-9 5/16" 6'-9 7/16" 6'-9 3/8" 5'-6 3/16" 50'-0" SECONDARY ELEVATION AT 1 VP Ref: Shape Name anger, Wall = 1 1, UNLESS NOTED, USE 1/2 X 1 1/2 A-325 SNUG TIGHTENED BOLTS FOR GIRT LAP, GIRT TO FRAME, FLANGE BRACE TO FRAME, FLANGE BRACE TO GIRT, JAMB AND HEADER CONNECTIONS. 2, WIND AND FLANGE BRACING ARE AN INTEGRAL PART OF THE WALL STRUCTURAL SYSTEM AND SHOULD BE PROPERLY INSTALLED PRIOR TO ERECTION OF WALL AND ROOF SHEETS. REMOVAL OR ALTERATION OF WALL BRACING WITHOUT PRIOR AUTHORIZATION IS PROHIBITED. THE VP EN WERE S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. NOT VP EN TO THE PERFORMA cs OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PER- £ORMANCE REQUIREMENTS SPECIFIED BY VP. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS, IT sPRO PROVIDED SOLELY O ELYFOR ERECTING THE oaoENG DESCRIEDINTHSHALL N BEDIFIEDREPRODUCHASEORDECED OR USED RAN ANYOTHni o v eIFEIEOR D s�PRIORWRITrEN VP Buildings, Inc. 3200 Players Club Circle Memphis TN 38125 SECONDARY ELEVATION AT 1 REV DATE BY DESCRIPTION BUILDER Teton West CUSTOMER LOCATION Rexburg, Idaho PROJECTNile Tanner �%n oea THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE, GOOD QUALITY WORKMANSHIP IN ERECTING THS BUILDING IN CONFORMANCE WTH THS DRAWNG,DETAILSREFERENCEDINTHIS DRAWINGABLE, ANDALL AINDUSTRYSTANDARDSPERTAIINIONGUIDNGTOPROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING, DATE 5/12/2005 ORAWNCHECK NITS BUILDER'S POa VPC VERSION. rj,'2b PAGE 5/17/2005 11:44:49 FILENAME 4091 Nile Tanner 50x50x17 5-12-05.VPC 2 1'-0,1 1 611 7Dimenaion Key 1, UNLESS NOTED, USE 1/2 X 1 1/2 A-325 SNUG TIGHTENED BOLTS FOR THE VP ENGINEER' S SEAL APPLIES PURLIN LAP, PURLIN TO FRAME, FLANGE BRACE TO FRAME, AND FLANGE PRODUT OF VPNLY ANDTDESIGNwORK AND PERFORMANCE BRACE TO PURLIN CONNECTIONS, REQUIREMENTS SPECIFIED BY VP. 2. WIND, FLANGE, AND PURLIN BRACING ARE AN INTEGRAL PART OF THE NOT APPLVP ENGINEER'S N To THE PERFORMANCE ROOF STRUCTURAL SYSTEM AND SHOULD BE PROPERLY INSTALLED PRIOR OR DESIGN OF ANY OTHER PRODUCT TO ERECTION OF WALL AND ROOF SHEETS. REMOVAL OR ALTERATION OF OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PER - ROOF BRACING WITHOUT PRIOR AUTHORIZATION IS PROHIBITED. FORMANCE REQUIREMENTSSPECIFIED BY VP. ----------02E2411414------------ ----------03E2411414:---- ............... . 36P2901014 26P2901014 36P2901012 26P2901013 .............................................:............... •................... I II 26P2901012(Typ.) . I I 36P2901011(TYP•) 26P2901013 36P2901012(Typ.) 26P2901012 36P2901013 26P2901012— ............... 36P2901014 26P2901014- . _____02E2411413__________ 03E2411414 I 24' -0 24' -611 1 50,-01, ROOF SECONDARY PLAN = cyan er THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS, B IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE IAPIPLICAEBLE PURCHASE �OJRDER AND SHALL THER PURPOSFEE�MYMOUTPRIOR WRIITENED FOR APPROVAL CC VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE, GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN CONFORMANCE VATH THIS DRAWING DETAILS RERENCED IN THIS DRAWING, ALL APPLICABLE VP C ON GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING, VP Buildings, Inc. 3200 Players Club Circle Memphis TN 38125 !EVI DATE I BY I DESCRIPTION ROOF SECONDARY PLAN ALDER Teton West 1STOMER 'CATION Rexburg, Idaho IIIECT Nile Tanner 11LDERS POM P BUILDINGS MRCORiU06V VPCVERsION, 5.2b 5117/2005 11, 44:48 ENAME 4091 Nile Tanner 50x50x17 5-12-05.VPC OFrame Member Schedule OA325 Bolt Connection 6 Plate Schedule Frame Clearances Part Mem, Width Thick. Webthk Depthl Depth2 Approx. Lgth Id Qty Bolt Bolt Plate Rows Rows Tension Washer Horiz. Clearance between members 1(CGX001) and 8(CGX001): 47'-0" CGX001 15" .0590 2131.0590 8 1/2" 8 1/2" 14'-8 7/16" Dia. Length Thick. Out In Bolt Vert. Clearance at member 1(CGX001): 15'-8 7/16" BGX001 2-45" .1200 213.1200 8 1/2" 8 1/2" 25'-0 3/4" A 4 1/2" 1 1/2" 3/811 1 1 Vert. Clearance at member 8(CGX001): 15'-8 7/16" BGX002 5-75" .1200 2@.1200 8 1/2" 8 1/2" 25'-0 3/4" B 4 3/4" 2" 1/2" 1 1 Vert. Clearance at member 9(EGX008): 16'-8 7/16" CGX001 85" 0590 2@.0590 8 1/2" 8 1/2" 14'-8 7/16" Vert. Clearance at member 10(EGX009): 16'-8 7/16" EGX008 95" 0590 213.0590 8 1/2" 8 1/2" 15'-8 5/8" Finished Floor Elevation = 100'-0" (Unless Noted Otherwise) EGX009 1051, .0590 2@.0590 8 1/2" 8 1/2" 15'-8 5/8" 8 19'-1" 7 3 3/8" 6 2 @ 2'-7 1/2" 5 1'-6 11/16" 4 1'-0" 3 1' -1 1/4" 2 2' -10 3/4" 1 9 1/2" Dimension Key 1. USE 1/2 X 1 1/2 A325 SNUG TIGHTENED BOLTS FOR PURLIN TO FRAME, GIRT TO FRAME, AND GIRT TO CLIP CONNECTIONS UNLESS NOTED OTHERWISE. 2. SLOT REINFORCEMENT PLATES NEED NOT BE LOCATED ON THE SAME SIDE OF THE WEB AS THE HILLSIDE WASHER. M 25`1 1/16" 1'000.1 4 @ 4'-6" 6 3' -6" THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PER— FORMANCE REQUIREMENTS SPECIFIED BY VP. A 2 5 5 25'-1 1116" 1.000:12 4 @ 41-6" 6 o O un Ln O O O n N N O 3'-0" �. 13'-6" 0'-0" FRAME CROSS SECTION AT FRAME LINES) 3 VP Ref: Shane Name = Hanaer Wall 4. Frame 3 IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND SHALL NOT BE ODIFIED REPRODU DOR USED FOR ANY OTHER PU POSE VVI'fHOUT PRIG WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE, GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN CONFORMANCE WRY. THIS ALL APPGI�D B�I.E VP REFERENCED GD IN S DRAVMJG, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING, VP Buildings, Inc. 3200 Players Club Circle Memphis TN 38125 IEV DATE BY DESCRIPTION NTS 5/17/2005 11:44:47 FRAME CROSS SECTION AT FRAME LINE(S) 3 Teton West Nile Tanner 4091 Nile Tanner 50x50x17 5-12-05.VPC JOB N DATE 5/12/2005 P BUILDINGS DRAwwcHECK wgcoaauoc+a VPCVERSION: 52b PAGE OFrame Member Schedule Part Mem. Width Thick. CX002 1 5" .3125 RBX003 2 5" .2500 3 5" .3750 RBX004 4 5" .3750 5 5" .2500 CX002 6 5" .3125 "Em 8 19'-1" 7 3 3/8" 6 2 @ 2' -7 1/2" 5 1' 6 11/16" 4 l'-O" 3 1'-1 1/4" 2 2' -10 3/411 1 9 1/2" Dimension Key OA325 Bolt Connection 6 Plate Schedule Webthk Depthl Depth2 Approx. Lgth Id Qty Bolt Bolt Plate Rows Rows Tension Washer .1875 1'-0" 2'-811 13'-10 13/1611 Dia. Length Thick. Out In Bolt .1875 2'-811 l'-9" 25'-0 3/411 A 16 3/4" 2 1/411 5/8" 4 4 .1345 1'-9" 2'-211 B 8 3/411 2 1/4" 5/811 1 3 .1345 2'-2" 2'-011 25'-3 1/8" .1875 2'-0" 2'-8" .1875 1'-0" 2'-811 13'-10 13/1611 M 25'-1 l/16" 1.000:1 6 4 @ 4 `6" (2)FB4054 FB3054 Frame Clearances Horiz. Clearance between members 1(CX002) and 6(CX002): 43'-111 Vert. Clearance at member l(CX002): 13'-10 13/1611 Vert. Clearance at member 6(CX002): 13'-10 13/1611 Finished Floor Elevation = 100'-011 (Unless Noted Otherwise) A 2 5 k- 1/16^ 1.000:12 4 @ 0 a a Ln r 0 0 N O O 1 M O N a^ IS: � 4 W W 44 W 0' —D' FRAME CROSS SECTION AT FRAME LINES) 2 0 Ln O N Ln PU U HD (2)FB4054 FB3054 n7 e CD N OIL) N VI' Her: sna a Name = rlanger Wall 4, name 2 1. USE 1/2 X 1 1/2 A325 SNUG TIGHTENED BOLTS FOR PURLIN TO SHE VP ENGINEER'S SEAL APPLIES THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINSTHEPROPERTYOFVPBUILDINGS , VP Buildings, Inc. FRAME, GIRT TO FRAME, AND GIRT TO CLIP CONNECTIONS ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE mSPROVIDED SOLELY FOR ERECTING THE BUILDING 3200Pla Players Memphis TN38125 Y P FRAME CROSS SECTION AT FRAME LINE(S) 2 UNLESS NOTED OTHERWISE, REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND ANY OTHERPURPOSE"V' OUTPRIORWRRENEOFOR REv DAe Br DESCRIPTION BUILDER Teton West eoea 2. SLOT R El NFORC EM ENT PLATES N E E D NOT BE LOCATED ON TH E SAM E NOT APPLY TO THE PERFORMANCE APPROVAL OF VP BUILDINGS SIDE OF THE WEB AS THE HILLSIDE WASHER, OR DESIGN OF ANY OTHER PRODUCT cusroMeR THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE, 0000 GUALITY WORKMANSHIP DATE 5/12/2005 OA COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PEA- ON LOCATIRexburg, FORMANCE REQUIREMENTS IN ERECTING THIS BUILDING IN CONFORMANCE WITH THIS DRAWING,DETA0.S REFERENCED IN THIS DRAWING, Idaho P BUILDINGS ORAWWCHECK SPECIFIED BY VP. ALL APPLICABLE VP ERECT ION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER PROJECT Nile Tanner wvcocauoeu ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BUILDER'S POa VPC VERSION PAGE BRACING, NTS 5.2b 5/17/2005 11:44:45 FILENAME 4091 Nile Tanner 50x50x17 5-12-05.VPC Frame Member Schedule Part Mem. Width Thick. CX001 1 5" .3125 RBX001 2 5" .3750 3 5" .3125 RBX002 4 5" .3125 5 5" .3750 CX001 6 5" ,3125 EGX001 7 5" .0590 EGX002 8 5" .0590 EGX003 9 5" .0590 EGX004 10 5" .0590 EGX005 11 5" 10590 EGX006 12 5" .0590 EGX007 13 5" .0590 8 19'-1" 7 3 3/8" 6 2 @ 2'-7 1/2" 5 1'-6 11/16" 4 1'-0" 3 1'-1 1/4" 2 2'-10 3/4" 1 9 1/2" Dimension Key Webthk Depthl .1644 1'-0" .1345 2'-3" .1345 1'-6" .1345 1'-10" .1345 1'-6" .1644 1'-0" 2@.0590 8 1/2" 213.0590 8 1/2" 213.0590 8 1/2" 213.0590 8 1/2" 20.0590 8 1/2" 213.0590 8 1/2' 2@.0590 8 1/2" _ / OA325 Bolt Connection & Plate Schedule Depth2 Approx. Lgth Id Qty Bolt Bolt Plate Rows Rows Tension Washer 2'-8" 14'-3 13/16" Dia. Length Thick. Out In Bolt 1'-6" 25'-0 3/4" A 16 3/4" 2 1/4" 5/8" 4 4 1'-10" B 8 3/4" 2" 1/2" 1 3 1'-6" 25'-2 3/4" C 2 3/4" 1 1/2" 2'-3" 2'-8" 14'-3 13/16" 8 1/2" 8" 8 1/2" 1'-7 1/16" 8 1/2" 2'-0" 8 1/2" 2'-4 7/8" 8 1/2" 1'-11 15/16" M 8 1/2" 1' 6 15 16" Frame Clearances Horiz. Clearance between members 1(CX001) and 6(CX001): 43'-1" Vert. Clearance at member 1(CX001): 14'-3 13/16" Vert. Clearance at member 6(CX001): 14'-3 13/16" Finished Floor Elevation = 100'-0" (Unless Noted Otherwise) A 'T 8 1/2" 8 1/4" 25'-1 1/16" 1.000:12 5 k=::::2 /65'-1 1 1 ^ 1.000;12 6 4 @ 4'-6" 4 @ 4'-6^ 6 FB4050 FB3050 a a 0 0 0 0 0 0 n 0 n N r p7 Cq O O N C.0 C>•I rI N -11"-+5'-6 3/16"+-6'-9 3/8" 6'-9 7/16"— }-6'-9 5/16" 6'-9 3/8"—+5'-6 5/16"+-5'-11" 50'-0" 1. USE 1/2 X 1 112 A325 SNUG TIGHTENED BOLTS FOR PURLIN TO THE VP ENGINEER'S SEAL APPLIES FRAME, GIRT TO FRAME, AND GIRT TO CLIP CONNECTIONS ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE UNLESS NOTED OTHERWISE. REQUIREMENTS SPECIFIED BY VP. 2. SLOT REINFORCEMENT PLATES NEED NOT BE LOCATED ON THE SAME THE VP ENGINEER'S SEAL DOES 140T APPLY TO THE PERFORMANCE SIDE OF THE WEB AS THE HILLSIDE WASHER. OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PER- FORMANCE REQUIREMENTS SPECIFIED BY VP. FRAME CROSS SECTION AT FRAME LINES) 1 T IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND SHALL NOT BE MODIFIED EPRODUCED OR USED FOR ANY OTHER PURPOSEWT OUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE, GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN CONFORMANCE WITH THIS DRAWING DETAILS REFER NCEO IN THIS DRAWING,ALLAPPLICABLEVPEREC NGUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING, VP Buildings, Inc. 3200 Players Club Circle Memphis TN 38125 tEV DATE BY DESCRIPTION NTS 5/17/2005 11:44:43 4050 3050 n c 0 N au N FRAME CROSS SECTION AT FRAME LINE(S) 1 Teton West Rexburg. Idaho Nile Tanner 4091 Nile Tanner 50x50x1 7 5-12-05.VPC JOB & DATE 511212005 P BUILDINGS DRAwwcHECK wacolwuori� VPCVERSION: 52b PAGE C- CD 0 T T T :X001 CX002 1 '-03RA250S I 03RA2 5 0 5 'EGX007 '-U3RA25o5 ; I ; f03RA2505 N c EGXO 0 6 c \o3RA26oS o xp� X�p fX R1 � I 6p5 1 li" EGX005 �p32 "'--o3RA2S ; 08 I ;_.,.0 3�2 5 p 9 `r'EGXO04.... ............................................. . ............................... .............. I p3RA2509 IEGX003 �03 �2605 0 0 0 �EGX002 /p3Rp2605 o3RA2505 03"2505 HEGX001 iO3PA25o5 f-03"2505 CGX001 rn c C W CX001 CX002 CGX001 24'-0" 24'-6'1 1 50'-0" PRIMARY AND ROOF BRACING PLAN 2 1'-0'1 1 61, Dimension Key VP Ref: Shane Name = Hanaer 1. USE 1/2 X 1 1/2 A325 SNUG TIGHTENED BOLTS FOR PURLIN TO THE VP ENGINEER'S SEAT. APPLIES THIS DRAWING. INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. VP Buildings, Inc. FRAME, GIRT TO FRAME, AND GIRT TO CLIP CONNECTIONS ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE mSPROVIDED SOLELY FOR EREMNGTHE BUILONG 3200 Players Club Circle Memphis TN 38125 y p PRIMARY AND ROOF BRACING PLAN UNLESS NOTED OTHERWISE, REQUIREMENTS SPECIFIED BY VP. DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND SHALL NOTBE MODIFIED REPRODUCED OR USED FOR 2. SLOT REINFORCEMENT PLATES NEED NOT BE LOCATED ON THE SAME THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE ANY OTHER PURPOSE WTYHOUTPRIOR , EN APPROVAL OF VP BUILDINGS REV DATE By DESCRIPTO" BUILDER Teton West JOBM SIDE OF THE WEB AS THE HILLSIDE WASHER, OR DESIGN OF ANY OTHER PRODUCT cusroMER THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE, GOOD QUALITY WORKMANSHIP DATE 5/12/2005 OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PEA- LOCATION FOAMANCE REQUIREMENTS IN ERECTING THIS BUILDING INCON50RMANCEWITH THIS Rexburg, Idaho A��n DRAWN HECK SPECIFIED BY VP. DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP ERECTION GUIDES, AND INSTANDARDS PERTAINING TO PROPER PROJECT Nile Tanner BRACTION, INCLUDING THE CORRECT USE OF TEMPORARY NTS BUILDER'S PC# VPC VERSION 52b PAGE 5/17/2005 11:44:42 FILENAME 4091 Nile Tanner 50x50x175-12-05.VPC ;1 E. 22 U.• 2 ur 64— �I 64mm 4 1 (4)3/4" Dia. A36 A.Bol late W=8" L=1'-1" lev.=100'-O" Dim A=1'-1" EL I VARIES BOTTOM OF COLUMN BASE PLAT STD - 1/2" (13n1m) -•(r=SH-T(Cn1m) TYPICAL COLUMN BASE PLATE DETAIL 2 (2)3/4" Dia. A36 A,Bol late W=8" L=10" levation=114'-0" 11 EM 10"kAWdm.' 22mm) Framed Opening LpenlnA Wltllh. A"(22Amm) I alk Door w/ Sub Frame �I MID, CIE �oe•mmwmn.<ta•(n<mml �1 V�aik Door wlo Sub Fralne FRAMED OPENING AT MASONRY A" 152mm - 4 @ ¢E 6 2 IIC" 2 I/Y' 21." VJ• mm `6� -63mm FL 4mm FL s D3 (4)3/4" Dia. A36 A.Bolts D4 (2)3/4" Dia. A36 A.Bo2 Plate W=8" L=1'-1" Plate W=8I, L=10" Elev.=100'-0" Dim A=1'-1" Elev.=101'-0" Dim A=1'-1" 112" (13mm) DIAMETER 6 1/6" 2 1/2" (64mm) CONCRETE ANCHORS PROJECTION (U.0 N.I (NOT BY VP) 30mm a BOTTOM OF COLUMN tL A EV. �- - w 1 1l4" OPENING W 0 IDTH 1 � � .mm — .mm _I 4" I N NOTE: 1"(25mm) PROJECTION ABOVE �? O1 BOTTOM OF JAMB CLIP 02mm TYPICAL ANCHOR BOLT PROJECTION FRAMED OPENING DETAIL D5 (2)3/4" Dia. A36 A.Bolts Plate W=81' L=10" Elevation=101'-0" Finished door tlevatlon = 100'-U•' Unless Noted OtheNvIse 1.CONCRETE, GROUT, ANCHOR BOLTS, AND ANY OTHER EMBEDDED ITEMS ARE THE VP ENGINEER'S SEAL APPLIES THIS DRAWING, INCLUDING THE INFORMATIONHEREON. REMAINSTHE PROPERTY OF VP BUILDINGS. VP Buildings, Inc. TO BE FURNISHED BY OTHERS ONLY TO THE WORK PRODUCT OF P VAND DESIGN AND PERFORMANCE ITISPROVIDED SOLELYFORERECTING THE BUILDING 3200 Players Club Circle Memphis TN 3B125 Y P ANCHOR BOLT PLAN - DETAILS 2. ANCHOR BOLT DIAMETERS WERE DETERMINED BYALLOWABLE SHEAR AND TENSION REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND SHALLNNY OTBEMODIFIEDREOPRODUCEDORUSEDFOR PER AISC SPECIFICATIONS (FY = 36 KSI). ANCHOR BOLT LENGTH, EFFECTS NOT APPLY To THE PERFORMANCE gNPROVALO VP BUILDINGS. PRIORWRFTEN REV DATE BY DESCRIPTION BUILDER Teton West OBp OF EMBEDDED ANCHOR BOLT EDGE DIMENSIONS AND METHOD OF TRANSFERRING OR DESIGN OF ANY OTHER PRODUCT CUSTOMER THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE, GOOD QUALITY WORKMANSHIP DATE 5/1212005 FORCES FROM ANCHOR BOLTS TO FOOTINGS ARE TO BE DETERMINED BY OTHERS. OR COMPONENT FURNISHED BY VP EKCEPT TO ANY DESIGN OR PER- 3. DESIGN LOADS AND REACTIONS ARE FURNISHED IN THE REACTIONS REPORT. FORMANCE REQUIREMENTS seEcxaxED BY VP, IN ERECTING THIS BUILDING IN CONFORMANCE VITHTHIS DRAWING DETAILS REFRENCED INTHS DRAWING, LOCATION Rexburg, Idaho P BUILDINGS DRAW CHECK 4. FOUNDATION MUST BE LEVEL, SQUARE AND SMOOTH. ANCHOR BOLTS MUST BE ALL APPLICABLE VP ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ROJECT Nile Tanner encoPauo� A CU AT Y AC AS HOW O S RAWNGO S NO IT, RACINGERECTION,INCLUDING THE CORRECT USE OF TEMPORARY NTS BUILDER'S PO! PC VERSION 52b PAGE 5/17/2005 11:44'A1 FILENAME' 4091 Nile Tanner 50x50x17 5-12-05.VPC 9- T T T \ e � W ! —F — 0 1O r cc \ m F �i —UP — 1 F i (F)- 1 11" Dimension Key 1. CONCRETE, GROUT, ANCHOR BOLTS, AND ANY OTHER EMBEDDED ITEMS ARE TO BE FURNISHED BY OTHERS 2. ANCHOR BOLT DIAMETERS WERE DETERMINED BY ALLOWABLE SHEAR AND TENSION PER AISC SPECIFICATIONS (FY = 36 KSI), ANCHOR BOLT LENGTH, EFFECTS OF EMBEDDED ANCHOR BOLT EDGE DIMENSIONS AND METHOD OF TRANSFERRING FORCES FROM ANCHOR BOLTS TO FOOTINGS ARE TO BE DETERMINED BY OTHERS, 3. DESIGN LOADS AND REACTIONS ARE FURNISHED IN THE REACTIONS REPORT. 4. FOUNDATION MUST BE LEVEL, SQUARE AND SMOOTH. ANCHOR BOLTS MUST BE I D3 i D4 I D2 '71 i i I i II I i I i i II D51 D2 Ir+ i I I i ,D2 , I I I D2 I I II I D2 D511 M li D2 FI, , i II,I D1 D3 T I D4' r THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP ExCE IT TO ANY DESIGN OR PER- FORMANCE REQUIREMENTS SPECIFIED BY VP. 25'-011 25'-0" 50'-0" ANCHOR BOLT PLAN = Iuu -u unless ivorea utneiwlse THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. R IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND SHALL NOT BE MODIFIED REPRODUCED OR USED FOR ANY OTHER PURPOSE VAYHOUTPRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE, GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN CONFORMANCE WITH THIS ALL APIPLIC ABLE VPRERECTIDN GUIDES IS DRAVANG, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY SPACING, VP Buildings, Inc. 3200 Players Club Circle Memphis TN 38125 IEVI DATE I BY I DESCRIPTION NTS 5/17/2005 11 A4:39 ANCHOR BOLT PLAN 11LDER Teton West 1STOMER 'CATION Rexburg, Idaho JOJECT Nile Tanner JILDER'S PON JOB M DATE 5/12/2005 VP BUILDINGS DRAwwcHECK wacomu VIC VERSION 5.2bPAGE E"ANTE 4091 Nile Tanner 50x50x17 5-12-05.VPC BUILDER/CONTRACTOR RESPONSIBILITIES FIRE CODE COMPLIANCE VP BUILDINGS CERTIFICATIONS VP Buildings follows the guidelines as outlined In the AISC and MBMA Codes of Standard Practice, VP Buildings standard product specifications, design, fabrication, quality criteria shall govern all work unless stipulated otherwise in the contract documents. In case of discrepancies between VP Buildings structural plans and plans for other trades, VP Building structural plans shall govern. It Is the responsibility of the Builder to obtain approvals and permits from all governing agencies and jurisdictions as required. Approval of VP Building drawings constitutes the builders acceptance of VP Interpretation of the contract purchase order. Unless specific design criteria concerning Interface design and details are furnished as part of the contract, VP Buildings design assumptions shall govern. VP engineers are not Project Engineers or Engineer of Record for the overall project. VP engineering supply sealed engineering design data and drawings for VP supplied material as part of the overall project for use by others to obtain permits, approvals, and coordinate with other trades The Builder or A/E firm are responsible for the overall project coordination, Including coordination with appropriate Inspection and testing agencies. All Interface and/or compatiblllty of any materials not furnished by VP are to be considered and coordinated by the builder or A/E firm. CONSTRUCTION & ERECTION RESPONSIBILITY The Builder Is responsible for construction In strict accordance with VP Buildings "FOR CONSTRUCTION" drawings and all applicable product Installation guides. VP Is not responsible for work done from any other VP drawings that are not marked "FOR CONSTRUCTION", nor any drawings prepared by others. The Builder Is responsible for accurate setting of anchor bolts (+- 1/8" accuracy), erection of steel, and required alignment such that components are straight and plumb per MBMA Code of Standard Practice. Out of stralghtness for any member shall not exceed 1/300. The bullding erector shall be properly licensed and experienced In erecting metal bullding systems. The Builder Is responsible for having knowledge of, and shall comply with, all OSHA requirements and all other governing site safety criteria. The builder Is responsible for designing, supplying, locating and installing temporary supports and bracing during erection of the bullding. VP bracing Is designed for code required loads after bullding completion and shall not be considered as adequate erection bracing. Se VP Builder Memo #BM-006. EXISTING STRUCTURES VP must be advised of any existing structure that Is within 20 ft. of VP's bullding. Loadings of both bulldings may be affected when adjacent buildings are within this distance. VP cannot be responsible for the design or loading of existing bulldings. BRACING Tension brace rods work In pairs to balance forces caused by Initial tensioning. Care must be taken while tightening brace rods to as not to cause accidental or misalignment of components. All rods must be Installed loose and then tightened. Rods should not exhibit excessive sag. For long or heavy rods, or angles ft may be necessary to support the rod at mid -bay by suspending ft from a secondary member. Bracing for seismic or wind loading of objects or equipment that are not a part of the VP structure must be designed by a qualified professional to deliver lateral loads to primary frames and rod bracing struts, Equipment bracing and suspension connections must not Impose torsion or minor axis loads, or cause local distortion In any VP components. VP accepts no responsibility for design or Installation of bracing systems not furnished by VP. FIELD WELDING All field welding shall be done at the direction of a design professional, and done In accordance with governing requirements (AWS In USA, CWB in Canada) by welders qualified to perform the welding as directed by the applicable welding procedure speclflcatlon (WPS). A WPS shall be prepared by the contractor for each welding variation specified. Unless otherwise approved, use E70ksl yield, low hydrogen electrodes. The contractor shall provide for any special welding Inspection as required by code. DELIVERIES It Is the responsibility of the builder to have adequate equipment avallable at the job site to unload trucks In a safe and timely manner. The Builder will be responsible for all retention charges from carriers as a result of job site unloading delays. Per VP Builder Memo #BM•001, claims for damage or losses MUST be noted on the BIII-of-Lading or delivery receipt and filed against the carrier by the consignee as per VP's Terms of Sales (F.O,B. Plant) under the Uniform Commercial Code. It Is critical that damages or loss be noted on the BIII-of-Lading or you have IlItle recourse with the carrier, Immediately upon delivery of material, material quantities are verified by the Builder against quantities billed on the shipping document. Neither the Manufacturer nor the carrier Is responsible for material shortages against quantities billed on the shipping document If such shortages are not noted on the shipping documents upon delivery of material and acknowledged by the carriers agent. For materials concealed In bundles, boxes, or crates, shortages must be reported Immediately upon unpacking. Should products get wet, bundled and crated materials must be unpacked and unbundled Immediately to provide drainage of trapped moisture. SEALANTS Sealants shall be applied In strict accordance with VP details or weather tightness will be compromised. Sealant must be applied In temperatures and weather condRlons consistent with labeling. Butyl Sealants - Service Temperature Range (Degrees): Min -40F (40C); Max 20OF (104C) Tape sealants - Service Temperature Range (Degrees): Min -60F (-50C); Max 212F (100C) INDEPENDENT MEZZANINES Independent mezzanines must be designed by a professional engineer. The engineer must ensure that proper Isolation from the VP building has been provided to avoid structural damage due to differential movements, or Inadvertently apply loads to the VP structure. VP accepts no responsibility for the design of the Independent mezzanine. It Is the responsibility of the project design professional and builder to comply with local flre code regulations Including consideration of, but not limited to, building use and occupancy, all bullding construction materials, separation requirements, egress requirements, fire protection systems, etc. Builder shall advise VP of any special requirements to be furnished by VP. VP steel roof systems are ICC Fire Class B roof assemblies. VP SSR steel roof systems are available for FM Class 1 fire rating. UL approved fire rated assemblies (1-1 1/2") - Design No, P265 and P268. FIELD MODIFICATIONS Modifications to this bullding from details and Instructions contained on these drawings must be approved In writing by VP Building engineers, or other licensed structural engineer. This Includes, but Is not limited to, removal of roof or wall cladding, removing or moving any flange braces or rod braces, cutting of openings for doors, windows or RTU's, correction of fabrication errors, etc. The owner shall not Impose loads to this structure beyond what Is specified for this bullding In the contract documents. VP Buildings, Inc. accepts no responsibility for the consequences of any unauthorized additions, alterations, or added loads to this structure. Per VP Builder Memo 9810-001, If the builder Intends to Invoice VP Buildings for modlflcatlons In excess of $1000, the builder must notify VP Buildings Immediately, and obtain a Work Authorization from VP Buildings prior to proceeding. All final claims must be submitted to VP Buildings with all supporting documentation within 30 days of the bullding completion. Claims submitted without work authorizations, or after 30 days will not be accepted. Correction of minor misfits, shimming and plumbing, moderate amount of reaming, drilling, chipping / cutting and minor welding are considered by Code of Standard Practice to be part of erection are not subject to claim reimbursement. CONCRETE/MASONRY/CONVENTIONAL STUD WALLS The engineer responsible for the design of the wall system Is responsible for coordinating with, or specifying to VP Buildings, any wall to steel compatibility Issues such as drift and deflection compatibility, special base detalls, and wall to VP steel connections. All fasteners, sealant and counter flashing of wall systems are to be provided by contractor. PANELS OII canning is an Inherent characteristic of cold formed steel panels. It Is the result of several factors that Include Induced stresses In the raw material delivered to VP, fabrication methods. Installation procedures, and post Installation thermal forces. Thru fastened panels will exhibit some dimpling when Installed, especially when Insulation Is Installed between panels and secondary supports. Dimpling can be minimized by careful Installation, taking care not to over drive fasteners. Roof rumble Is a phenomenon that Is caused by wind gusts Iltting up on the roof panels and then springing back Into place. All panels experience this action to some degree, especially with concealed clip panels such as SSR and SLR, Roof rumble noise may be minimized by providing a layer of blanket insulation between the panels and any hard support surface such as steel secondary members, substrates such as plywood, steel decking, or rigid board Insulation. A minimum of 3 Inch thick blanket Is recommended over steel secondary members, or 2 Inch over substrates. Oil canning, dimpling, and roof rumble do not affect the structural Integrity or weather tightness of the panels and Is not grounds for rejection of panels. SKYLIGHTS VP's Tuflltes and VP's domed skylight have been tested to support a 300 lb. load over a 1 sq. it. area, as well as uniform gravity and uplift load test. Local bullding departments may require added fall restraint due to conditions that may affect the skylight structural Integrity. It Is the responslbllky of the builder to determine and provide any added fall restraint under the skylight as may be required by your bullding department. RAIN WATER RUNOFF Drainage systems must be designed by the project engineer to comply with code requirements. VP Is not responsible for drainage designs, overflow scuppers, down piping, etc. The project professional and contractor are responsible to ensure that overflow devices such as scuppers and auxlllary drains are provided as required for the required rain Intensity at the bullding perimeter and at valley conditions to prevent bonding. STEEL SHOP COAT The purpose of VP's shop coat Is to provide protection for the steel members during transportation, during temporary job site storage and during erection Standard shop formulation Is not designed to perform as a finish coat when exposed to environmental conditions. Members shall be kept free of the ground and properly drained during job site storage. It Is the Builder's responsibility to ensure that If a finish coat Is being applied over VP shop coat that the painting contractor verifies compatibility between his finish coat and VP's shop coat. See VP Builder Memo #BM-001 8 #BM-002, THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE AEQUI RE MEETS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PER- FORMANCE REQUIREMENTS SPECIFIED BY VP. PLANT SPECIFIC CERTIFICATIONS a ama Arkansas Calltornla M ssour o. Carolina Wisconsin Mexico AISC art. M art. M art. M art. eft. eft. M art. ISO 0 1 0 IAS FA-377 FA-401 FA-240 FA-388 FA-376 FA-378 CSA-A660 VPBULO VPBUIO OWE DM. 1 DIV. 1 Los Angeles, CA Div. 1 DIV. 1 Houston, TX Approved Approved Riverside, CA Type 1 Fab #SP02.0028 Clark Co., NV Fab ID# 241 San Bernardino Co, CA Fab ID#121 ICC Evaluation Reports SSR Roof System - #ER-5621 Panel Rib Roof and Wall - #ER-4879 Vee Rib Wall - #ER-4879 State of Florida Product Approval (Listed as VP Buildings) Dade Co. Product Certification SSR Roof NOA#03-0206.13; Panel Rib Roof NOA#02-0123.08; Panel Rib Wall NOA#02-04187.01; Vee Rib Wall NOA#Ot-1128.05 Underwriter's Laboratory Approvals SSR Roof-UL#TGKX-113; SSR Composite Roof Class 90-UL#TGKX-113A; SSR Roof w/Super Block Class 90-UL#TGKX-328; Panel Rib Roof UL Class 60-UL#TGKX-60; Panel Rib Roof UL Class 9D-UL#TGKX-64; VP SLR/AEP SL Roof Class 90-UL#TGKX-60 Factory Mutual Approved Assemblies SSR Roof Systems are approved In various type applications and listed In FM Approval Guide. 24 Ga SSR (0.0227" Nominal), Is available In Class 1-60, 1-75, 1.90 22Ga SSR (0.0277" IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND ANY OTHER PURPOSE v°tROUT PRIOR WRITTENED FOR APPROVAL OF VP BUILDINGS, Nominal), Is available In Class 1-75. 1-90-, 1-120, THE GENERAL CONTRACTOR ANCIOR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE, GOOD OUALITY WORKMANSHIP IN ERECTING THE BUILDNG IN CONFORMANCE WITH THIS AL APPLICABLE VPRERECTEION GLID S, DRAWING, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. VP Buildings, Inc. 3200 Players Club Circle Memphis TN 38125 EV DATE BY DESCRIPTION NTS 5/17/2005 11:44:38 Erection Notes JILDER Teton West ISTOMER CATION Rexburg, Idaho IIIECT Nile Tanner ALDER'S PC4 ENAME 4091 Nile Tanner 50x50x17 5-12-05.VPC VP BUILDINGS YMCOPR'JDEN VPC VERSION'. 5 2b ice I