Loading...
HomeMy WebLinkAboutREDLINED SITE PLAN - 21-00717 - Metal Office Building Vet ClinicAuthor Name Author Email Author Phone No.: Stan Crittenden Stan.Crittenden@rexburg.org 208-372-2314 Description : RP05N39E144212 - Metal Office Building Address : RP05N39E144212 Application Type : Document Filename : J.D. FOLSON THORNTON 7-21-21.pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments 4 SITE OVERVIEW Callout Stan Crittenden : Fire Open 4 Building square footage calls out 5000 sq.ft. What is the additional 25' shown? 4 SITE OVERVIEW Callout Stan Crittenden : Fire Open 4 Need to verify "Heavy Truck" rating. Required to be rated for over 75,000 lbs. 4 SITE OVERVIEW Free text Stan Crittenden : Fire Open 4 Fire Department Notes: - Building Type and Occupancy classification? - Fire Suppression? If this is a IIB construction type, 5000 sq.ft. will require 1500 gpm for 2 hours duration water supply. # 21-00717 Madison County - Commercial Report Date: 10.21.2021 Approval of plans does not constitute approval of variance from code Page 1 of 1 Powered by TCPDF (www.tcpdf.org) SITE MAP VICINITY MAP Date: Connect Engineering APPROVAL SIGNATURES: of DEVELOPMENT DRAWINGS FOR: STATE MAP SHEET NO. PLOT DATE: 7/21/2021 4:46 PM Date: The Civil Connection 1150 Hollipark Dr. Idaho Falls, ID 83401 208.881.0081 1 8 J.D. FOLSON THORNTON MADISON COUNTY, ID MADISON COUNTY. ID PRELIMINARY FOR REVIEW ONLY THORNTON, ID Sheet List Table Sheet Number Sheet Title 1 COVER 2 NOTES 3 REFERENCES 4 SITE OVERVIEW 5 SEPTIC SYSTEM 6 SEPTIC SYSTEM DETAILS 7 BEST MANAGMENT PRACTICES 8 BEST MANAGMENT PRACTICES DETAILS 100-1 RETAIN AND PROTECT 706-S1 4' SIDEWALK SEE SHEET 3 FOR MORE INFORMATION 706-F1 1.00' FLUSH CURB 707-T1 INSTALL CURB TERMINUS 706-1 6'' CURB AND GUTTER PER ISPWC 4851.11 BTM 4851.91 BTM 4851.92 BTM 4853.92 TOP 4853.91 TOP 4853.11 TOP 4854.60 TBC-MATCH 4854.60 TBC-MATCH 4854.42 TBC-PI 4855.28 TBC 4855.67 TBC-PI 4855.50 TBC 4854.89 TBC-PC FF: 4856.25 4855.30 GB HP 4854.86 TOA 4 8 5 5 48 5 4 4853 4852 48 5 4 48 5 3 48 5 3 4853 48524852 4 8 5 6 -3.91% -3.45% -2.38% -0.46% -3.37% -5.89% -2.01% -2 . 3 1 % -2 . 0 2 % -2.18% -2.62% -3.06% - 2 . 3 6 % -2 . 5 4 % -3 . 0 5 % -0 . 2 5 % 4856.27 EXIST ELV 4856.49 EXIST ELV 4854.39 EXIST ELV 4854.01 EXIST ELV 4853.93 EXIST ELV 4854.92 EXIST ELV 4855.31 EXIST ELV 53 . 3 6 ' 4855.19 EXIST ELV 4855.48 EXIST ELV 4855.42 EXIST ELV -3.01% -2 . 0 0 % -2 . 0 0 % -5 . 4 4 % 4856 4854.85 TBC END 4855.09 TBC END 4855.09 TBC 4855.09 TOA 4856.25 TBC END -0.40% -0 . 6 5 % -0 . 5 9 % -2 . 1 8 % 4854.85 GB HP 4853.95 GB LP 4851.92 BTM 4854.92 TBC END 33 . 3 7 ' 20 . 0 0 ' 10.00' 4856.12 TBC HP 4853.91 TOP 4855.77 TOA 4855.77 TOA - 2 . 8 1 % - 0 . 3 4 % 4855 4855 Control Point Table Point # 1 Elevation 4856.33 Northing 766238.18 Easting 741815.30 Description 1/2IP APPROVED BY ________________________DATE:____________ MADISON COUNTY SURVEY NOTE: This site plan conforms to an actual survey that was performed on the ground by a licensed land surveyor in and for the State of Idaho. It is the owner’s responsibility to construct all structures shown on this site plan in accordance with said survey. CHECK BY SHEETS DRAWN BY JOB NO: DATE: OF SHEET BDJTT SH E E T N A M E : PR O J E C T : LO C A T I O N : 2020-101 DATE:DATE: July 21, 2021 DA T E RE V I S I O N S CL I E N T : Th e C i v i l C o n n e c t i o n 11 5 0 H o l l i p a r k D r . I d a h o F a l l s , I D 8 3 4 0 1 20 8 . 8 8 1 . 0 0 8 1 PRELIMINARY FOR REVIEW ONLY 4 8 J. D . F O L S O N T H O R N T O N SI T E O V E R V I E W MA D I S O N C O U N T Y , I D 706-F1 SEE SEPTIC SYSTEM DETAILS SHEET 7 AREA 1 AREA 2 AREA 3 10 0 . 0 0 ' 50.00' 20 . 0 0 ' 10.00' 37.17' AREA: 40,147 SQ FT (0.92 ACRES) ZONE: C-COMMERCIAL BUILDINGS: 1 TOTAL -BUILDING SQ FT: 5000 SQ FT -BUILDING HEIGHT: 20 FT SITE INFORMATION STORM WATER STORAGE NOTE: TOTAL REQUIRED: 7820*1.3/12= 847.2 CU FT TOTAL PROVIDED: 919.6 CU FT706-F1 706-1 706-1 706-F1 TOTAL REQUIRED: 7377*1.3/12= 799.2 CU FT TOTAL PROVIDED: 881.01 CU FT TOTAL REQUIRED: 24950*1.3/12= 2703 CU FT TOTAL PROVIDED: 2706.8 CU FT AREA 1 - AREA 2 - AREA 3 - 707-T1 706-F1 PROPOSED WELL PROPOSED SERVICE LINE 25.00' 54 . 6 6 ' 34 . 6 5 ' 24.07' 100-1 EXISTING DITCH 707-T1 STORM WATER INFORMATION SCALE 1'' = 70' 100-1 100-1 706-F1 706-F1 Building square footage calls out 5000 sq.ft. What is the additional 25' shown? Need to verify "Heavy Truck" rating. Required to be rated for over 75,000 lbs. Fire Department Notes: - Building Type and Occupancy classification? - Fire Suppression? If this is a IIB construction type, 5000 sq.ft. will require 1500 gpm for 2 hours duration water supply.