HomeMy WebLinkAboutHOOD/FIRE SYSTEM INSPECTION - 11-00106 - El Garden Construction PermitADDRESS O(�a SINGLE CITY f �,P ❑ 1 � � � L1 DOUBLE PHONE_ ' Lll " El TRIPLE ❑OTHER _ OWNER OR MANAGER 1{4 �1� i !1f� f.` YES NO N/A 1. All seals intact, no evidence of tampering Kitchen Hood Fire System Inspection & Maintenance Report FIRE777�� 2. All appliances properly covered w/correct nozzles ❑ ❑ SERVICJE' Phone 1-800-866-3640 ❑ TIME ❑°PM of IDAHO, Fax 1-208-232-0449 Locally Owned a Operated ❑ NEW INSTALL ❑ ❑ 5. Hood/duct penetrations sealed ❑ ANNUAL❑ AMEREX 1:1KIDDIE ElRANGE GUARD NAME ❑ SEMI-ANNUAL ❑ ANSUL ❑ PYRO-CHEM ❑ OTHER - J ❑ RECHARGE ❑ BADGER ADDRESS O(�a SINGLE CITY f �,P ❑ 1 � � � L1 DOUBLE PHONE_ ' Lll " El TRIPLE ❑OTHER _ OWNER OR MANAGER 1{4 �1� i !1f� f.` YES NO N/A 1. All seals intact, no evidence of tampering ❑ ❑ ❑ 2. All appliances properly covered w/correct nozzles ❑ ❑ ❑ 3. Duct and plenum covered w/correct nozzles ❑ ❑ ❑ 4. Check positioning of all nozzles ❑ ❑ ❑ 5. Hood/duct penetrations sealed ❑ ❑ ❑ 6. Grease accumulation ❑ Excessive ❑ Heavy ❑ Moderate ❑ 7. Pressure gauge in proper range 8. Checked cartridge weight 9. Cylinder hydrostatic test date 10. Inspect cylinder and mount 11. Checked travel of cable and link position ❑ ,❑ ❑ ❑ ❑ ❑ ❑ 360° =&TYPE 1:1450- E] 450°❑ 500° ❑ OTHER LOCATION OF SYSTEM ALL YES NO N/A 20.Proper separation between fryers and open flame 21. Exhaust fan in operating order 22. Remote manual release seals in place 23. System cartridge replaced / safety pins removed 24. System operational and armed 25. Fan warning sign on hood 26. K class fire extinguisher in cooking area 27. Proper ABC fire extinguisher for other areas six year maintenance 28. Fire extinguishers properly serviced ❑ ❑ ❑ 29. Personnel instructed in manual operation of system ❑ ❑ ❑ 30. Personnel instructed on required monthly insp. of Sys. 12. Fusible links 360 450 500 31. Personnel instructed on use of fire extinguishers 13. Replaced fusible links, manufacture date: ❑ ❑ ❑ 32. Service and certification tag on system 14. Checked manual release ❑ ❑ ❑ 33. Originally installed as a UL 300 compliant system? 15. Checked micro -switch ❑ ❑ ❑ 34. Is the system as currently configured 16. Checked gas valve mech.- electric - ❑ ❑ ❑ a UL 300 compliant system? 17. Piping/conduit securely bracketed ❑ ❑ ❑ 18. Nozzles cleaned / Chear of Blockage ❑ ❑ ❑ 19. Proper nozzle caps / covers in place ❑ ❑ ❑ ❑ ❑ ❑ El ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ El ❑ ❑ ❑ ❑ ❑ El ❑ ❑ ❑ ❑ ❑ ❑ 71 El ❑ ❑ ❑ ❑ ❑ ❑ ■ ■ NOTE: Non compliance systems may fail to extinguish/suppress fire COMMENTS / NON COMPLIANCE: On this date, the above system was tested and inspected in accordance with procedures of the presently adopted editions of NFPA 17, 17A, 96 and the manufac- turer's manual and was operated according to these procedures with results indicated above. X e�,> SERVICE TECHNICIAN DATE TIME AM PM CUSTOMER'S AUTHORIZED SIGNATURE The above service technician certifies that the system was personally inspected and found conditions to be as indicated on this report.