HomeMy WebLinkAboutFS PLAN - 21-00488 - Denny's - New Commercial BldgSCOPE OF WORK
LONGITUDINAL BRACE DETAIL
SOLID WOOD BEAM
TO
FIG 90 p p
TOLCO FIG 98
BRACEANGLE --..
45°-59°
1"SCH.40 PIPE
TOLCO FIG 4L,x
SPRINKLER PIPE
LATERAL BRACE DETAIL
COMPOSITE WOOD JOIST (TJI)
1-1/2"x6"x 12" WOOD BLOCKING (2) III
THOUGH BOLT Mlu
TOLCO FIG 980 III
BRACE ANGLE
45°-59°
V. 6 VSCH49PIPE
TOLCO FIG 1000 p ; "FASTCLAMP" SPRINKLER PIPE
�'/
LATERAL BRACE DETAIL
SOLID WOOD BEA
TOLCO FIG 90
THOUGH BOLT (2
TOLCO FIG 98
BRACE ANGLE
45°-59°
V SCH 40 PIPE
I'
TOLCO FIG 100
"FAST CLAMMP"P" SPRINKLER PIPE
SIDE SAMMY W/ SWIVEL
REMOTE INSPECTORS TEST
WET SYSTEM AIR VENT
--\\\\�Pl-
ZEE PURLIN �I
BRANCHLINE H�F
1/2"XO-3 NIPPLE
�SAMMY SIDEWINDER
90°ELBOW ! 12"PLUG
fTOLCOFIG]S SWIVEL
1"SCH.40 PIPE
1/T 13NIPPLE I-
-ALLTHREAD ROD
1"GLOBEVALVE Hr IHHT..
-VTILL VALVE
\I
-
1" UNION � �
(/
(, � I ` BRANCHLINE
SWIVEL RING
PIPE
1" GALV 45°
-
wJIIT ORIFICE
NOTE'. A SINGLE AIR VENT SHALL BE LOCATED
NEARAHIGHPOINT INTHE SYSTEM.
WOOD SIDE SAMMY SCREW
WOOD JOIST -
TRAPEZE HANGER DETAIL
rr BEAM/JOIST
II
++ TOP BEAM CLAMP
BRANCHLINE RESTRAINT
(STEEL BEAM)
STEEL BEAM /JOIST
SAMMYSCREW
BALL THREAD ROD
3/8"ROD - III
PIPE MF
3CLBEAM
CAMP
U
hlr
- Iuulryl
3/8"RODI
ALL THREAD ROD
BEAM CLAMP
TOLCO SWIVEL
SWIVEL RING
(FIG ]5)
uull
3
SWIVEL RING ��
/�
3/8"ROD
PIPE
f
PIPE
SWIVEL RING
BRANCHLINE PIPE
REFERENCE NFPA 132019, SECTION 17.1.1 FOR SIZING
UPRIGHT SPRINKLER DETAIL
UPRIGHT SPRINKLER
C\WELDED OUTLET
� Q BRANCHLINE PIPING
INSTALL SPRINKLER V-12" BELOW DECK
HANGER SPACING -STEEL PIPE
SIZE OF PIPE
MAXHANGER
WEIGHTOFWATER
SUPPORTED
SPACING
FILLED PIPE
1" (Sch 40)
12'-0
2.05 lbs/H
11/4"(Sch 40)
12'-0
2931Wft
11/2"(Sch 10)
15'-0
3041Wft
2" (Sch 10)
15'-0
4.22 lbs ft
21/2" (Sch 10)
151-0
5.891bs/ft
3" (Sch 10)
15'-0
].941b /ft
4" (Sch 10)
15'-0
11.781Wft
6(Sch 10)
15'-0
23.03 lbs/ft
UPRIGHT SPRINKLER DETAIL
CEILING
AT
UPRIGHTSPRINKLER --.
I�
1"SCH 40 PIPE 1"X 112" ELBOW
STEEL PIPE DIMENSION TABLE
SCHEDULE 10 PIPE
SCHEDULE 40 PIPE
NOMINAL INSIDE
PIPE SIZE DIAMETER
(IN.) (IN)
NOMINAL
PIPE SIZE
(IN.)
INSIDE
DIAMETER
(I N.)
1" 1.097
V
1.049
1'/." 1.442
1'/V
Two
VA- 1.682
2" 2.157
1'A"
2"
1.610
2.067
21/2" 2 635
2"h"
2 469
3" 3.260
3"
3.068
4" 4.260
4"
4.026
6" 6S57
6"
6.065
8" 8.249
8"
1.981
4 WAY RISER BRACE DETAIL
L CONCRETEWAL4
KWIKBOLTANCHOR�
TOLCO FIGIII
1"SC1.40 PIPE
a
TOLCO FIG 100 RISER PIPE
"FAST CLAMP"
PENDENT& UPRIGHT SPRINKLER
=SSU SPRINKLER
1"SCH.40 SPRIG-� �VARMOVER
11190°ELB,r[O3.'T'"ELBOW
BRANCHLINE= - ~1"SCH,-DROP
1"X 1/2" R.C.
CEILING
SEE PLAN FOR HEIGHT g�SEMI-RECESSED
SPRINKLER
SPRINKLER AND HANGING DETAILS
TT
RISER DETAIL
NO SCALE
1. 2" TO WET SYSTEM
2. HYDRAULIC INFORMATION SIGN
3. 21/" RELIABLE CR RISER W/TEST, DRAIN, AND GAUGE FOR
SUPPLY PRESSURE
4. 1-1/4" MAIN TESTAND DRAIN
5. 2 '/" AM ES C200 BFP
6. 6" UNDERGROUND STUB IN BY OTHERS
7. GENERAL INFORMATION SIGN
8. 21/" BUTTERFLY VALVE
9. 21/" FORWARD FLOW BYPASS
10. 21/" CHECK VALVE WITH BALL DRIP
11. 3" x 2'/" FIRE DEPARTMENT CONNECTION
NO SCALE
ECTION
VIEW Al 1-0 2 4
SCALE 1/4" = 1'-0" ( �1
NORTH
TO CITY GRID
PRESSURE HYDRANT 1
j
SITE PLAN
T
6
6-3
6
47'-3
DESIGN AND INSTALLA SINGLE ZONE WETAUTOMATIC FIRE SPRINKLER SYSTEM FOR THE NEW DENNY'S
RESTARAUNT LOCATED AT 585 NORTH 2ND EAST REXBURG, ID 83404. MAIN FLOOR TO BE SPRINKLED PER
LIGHT HAZARD OCCUPANCY EXCEPT KITCHEN AREA WHICH WILL BE SPRINKLED PER ORDINARY II
HAZARD. THE HEATED COMBUSTIBLE CONCEALED SPACE SHALL BE SPRINKLED WITH BRANCH LINES
RUNNING THROUGH THE WOOD TRUSSES. SYSTEM TO BE SUPPLIED BYA 6" UNDERGROUND LEAD IN
INSTALLED, TESTED AND FLUSHED BY OTHERS. SYSTEM DESIGN SHALL BE IN ACCORDANCE WITH NFPA
13 2019 EDITION AND LOCAL AUTHORITY.
DESIGNED BY:
SEAN SMALL
208-881-5414 - OFFICE
6312 S. BURGRAFF WAY
IDAHO FALLS, ID 83402
AUTHORITY HAVING JURISDICTION:
STAN CRITTENDEN, MADISON FIRE DEPARTMENT
26 NORTH CENTER STREET, REXBURG, ID 83440
(208) 716-3368
GENERAL CONTRACTOR:
TOD PETERSON
EcoCon LLC
105 E 400 S, BURLEY, ID 83318
GENERAL NOTES
1. SYSTEM DESIGN, INSTALLATION AND TESTING SHALL BE IN ACCORDANCE WITH NFPA 13 (2019 EDITION)
AND LOCAL FIRE AUTHORITY.
2. ALL MATERIAL AND DEVICES TO BE U.L. LISTED AND/OR F.M. APPROVED FOR FIRE SPRINKLER USE.
3. ALL 1" SYSTEM PIPING SHALL BE SCHEDULE 40 BLACK PIPE WITH THREADED Cl FITTINGS.
4. ALL SYSTEM PIPING 1%"AND LARGER SHALL BE SCHEDULE 10 BLACK PIPE WITH GROOVED FITTINGS &
GROOVED RIGID COUPLINGS.
5. PIPE SHALL BE MANUFACTURED TO MEETASTM A135 STANDARDS. CRR VALUE = 1.0 OR GREATER
6. ALL HANGERS SHALL BE DESIGNED, SPACEDAND INSTALLEDAS PER NFPA-13, 2019 EDITION,
CHAPTER-18. MAX LENGTH OF UNSUPPORTEDARMOVERS SHALL BE 24" (PRESSURE LESS THAN 100 PSI).
7. SPRINKLERS LOCATED IN ACOUSTICAL GRID CEILINGS SHALL BE INSTALLED CENTER OF TILE OR
QUARTER POINTS.
8. ALLALARM SYSTEM, PAINTING, WIRING, FIRE EXTINGUISHERS, HYDRANTS, THRUST BLOCKING, CITY
WATER CONNECTION, EXCAVATION, BACKFILLING, 24 HOUR SUPERVISION, AND SYSTEM MONITORING
INSTALLATION IS BY OTHERS.
9. FLUSHING AND TESTING OF UNDERGROUND PIPING SHALL BE COMPLETED BY THE INSTALLING
CONTRACTOR BEFORE CONNECTION TO THE FIRE SPRINKLER SYSTEM.
10. ALL PENETRATIONS THROUGH FIRE RATED ASSEMBLIES SHALL BE FIRE STOPPED. FIRE STOPPING
MATERIAL SHALL BE INSTALLED PER MANUFACTURERS INSTRUCTION BY OTHERS.
11. HYDRAULIC PLACARD SHALL BE POSTED ON RISER.
12. BUILDING OWNER SHALL BE RESPONSIBLE FOR ADEQUATE HEAT (40°FANDABOVE) IN ALL WET PIPE
AREAS TO PREVENT SPRINKLER SYSTEM FROM FREEZING.
SYSTEM DESIGN NOTES
THIS AUTOMATIC SPRINKLER SYSTEM IS SIZED BASED ON HYDRAULIC CALCULATIONS IN ACCORDANCE
WITH THE REQUIREMENTS OF NFPA 13 2019 EDITION DENSITYAREA METHOD. FIRE SPRINKLER SYSTEM
IN AREA OF WORK IS DESIGNED TO LIGHT HAZARD OCCUPANCY UNLESS NOTED OTHERWISE.
PERMISSIBLE DECREASES FROM NFPA 13 HAVE BEEN APPLIED TO DESIGN AREA.
WATER SUPPLY DATA:
STATIC PRESSURE: 80
RESIDUAL PRESSURE: 70
FLOW: 1800
DATE: 06/28/2022
SOURCE: 3-D FIRE PROTECTION FLOW TEST
BUILDING DETAILS
- BUILDING STRUCTURE AND CONSTRUCTION CONSISTS OF:
-CONCRETE FOUNDATION
-WOOD FRAMING
-SHEETROCK INTERIOR WALLS
-TOTAL SQUARE FOOTAGE: 8,820 FT2
MAIN LEVEL: 4,410 FT2 - 40 SPRINKLER HEADS
COMBUSTIBLE CONCEALED SPACE: 4,410 FT2 - 39 SPRINKLER HEADS
00 - BUILDING CODE CLASSIFICATION
- OCCUPANCY - A-2 - RESTAURANT, FOOD AND/ OR DRINK MORE THAN 50 OCCUPANTS
(Q - CONSTRUCTION TYPE - V B - UNPROTECTED WOOD FRAME
WATER SUPPLY
INFORMATION:
FLOW: 1800 GPM
STATIC: 84
RESIDUAL: 70
FLOW HYDRANT
116-1
0 4 8 16
SCALE 1/16" = V-0"
1116" = V-O
TO CITY GRID
Idaho Falls, ID
Tel. 208-881-5414
Idaho License Number: FPSC-08
Sean.SmalI@3Dfire.us
OWNERSHIP OF DOCUMENTS
ALL DRAWINGS, SPECIFICATIONS, AND OTHER WORK PRODUCT
OF 3-D FORTH IS PROJECTARE INSTRUMENTS OF SERVICE
FOR THIS PROJECT ONLY AND SHALL REMAIN THE PROPERTY
OF 3-D W NETHER THE PROJECT IS COMPLETED OR NOT.
REUSE OF ANY OF THE INSTRUMENTS OF SERVICE, BY THE
OWNER OR EXTENSIONS OF THE PROJECT WITHOUT WRITTEN
PERMISSION OF 3-D SHALL BE ATTHE OWNER'S RISKAND THE
OWNER AGREES TO DEFEND, INDEMNIFY, AND HOLD
HARMLESS 3-D FROM ALL CLAIMS, DAMAGES, AND EXPENSES
INCLUDING ATTORNEYS' FEES ARISING OUT OF UNAUTHORIZED
REUSE OF THE INSTRUMENTS OF SERVICE BYTHE OWNER OR
BY OTHERS ACTI NG THROUGH THE OWNER
FREEZING CONDITIONS
IN LOCATIONS SUBJECTTO FREEZING CONDITIONS,
IT ISTHE OWNERS RESPONSIBILITY TO PROVIDE HEATAND
ADEQUATE INSULATION THROUGHOUT WET PIPE SPRINKLER
SYSTEM AREAS AND IN ENCLOSURES FOR DRY PIPE AND
OTHER TYPES OF VALVES CONTROLLING WATER SUPPLIES TO
SPRINKLER SYSTEMS.
I have reviewed these plans and
certify that they comply with the
adopted N FPA standards.
Nicet Name Corey Thompson
NICET Level IV 116184
Date of Review 07/07/22
Signature
❑AS-BUILTNSUBMITTAL❑ OTHER
REVISIONS
NO.
DATE
DESCRIPTION
07/07/22
FOR APPROVAL
zh
0
A
CL
LL
LL
LL
LL
Lo
C,
0
0
0
N
N
N
NEEEN
E222
N
U
U
U
U
a
a
c
a�
c
a�
�
•
t
CL
rn
H
a�i
a�i
a
[L
0-
0
c0
LL.
6
U i
Uri
ui
�
Y
iC
(D
0)
J
M
M
(V
M
II
Fu
0
H
CL
CO
CO
CO
CO
7
0
0
0
LSD
O
LL
0
LL
LL
U-
u-
LL
LL
z
vIt
LO
<
<
a�
U
sz
s?
s?
SZ
N
N
I6
f6
C
D_
W
W
W
N
O
E
1
r�
DRAWN BY
SEAN SMALL
3-D FIRE PROJECT NUMBER
4CO093
i
c i
c
X
W
M
,O
t�
N
6-
1.%
�a.
+
O
m
r
Z
X
U-
r
00
[+M
PRINT DATE
07/07/22
FP-0 1
Hydraulic Information
Remote Area 2
OCCUPANCY CLASSIFICATION
Light Hazard
DENSITY (gpmlft2)
0.10 for 1500ft2 (Actuc-
QUICK RESPONSE REDUCTION
12'-6 Ceiling (36.3%)
TOTAL HOSE STREAMS
100.00
TOTAL HEADS FLOWING
8
K-FACTOR
5.6
TOTAL WATER REQUIRED
305.59
TOTAL PRESSURE REQUIRED
74.405
BASE of RISER (gpm)
305.59
BASE of RISER (psi)
74.405
SAFETY MARGIN (psi)
+5.218 (6.6%)
MAIN FLOOR SPRINKLER PLAN
1 0 2 4
SCALE 1/4" = V-0"
114" = V-0
Idaho Falls, ID
Tel. 208-881-5414
Idaho License Number: FPSC-08
Sean.SmalI@3Dfire.us
OWNERSHIP OF DOCUMENTS
ALL DRAWINGS, SPECIFICATIONS, AND OTHER WORK PRODUCT
OF 3-D FORTH IS PROJECTARE INSTRUMENTS OF SERVICE
FOR THIS PROJECT ONLY AND SHALL REMAIN THE PROPERTY
OF 3-D W NETHER THE PROJECT IS COMPLETED OR NOT.
REUSE OF ANY OF THE INSTRUMENTS OF SERVICE, BY THE
OWNER OR EXTENSIONS OF THE PROJECT WITHOUT WRITTEN
PERMISSION OF 3-D SHALL BE ATTHE OWNER'S RISKAND THE
OWNER AGREES TO DEFEND, INDEMNIFY, AND HOLD
HARMLESS 3-D FROM ALL CLAIMS, DAMAGES, AND EXPENSES
INCLUDING ATTORNEYS' FEESARISING OUT OF UNAUTHORIZED
REUSE OF THE INSTRUMENTS OF SERVICE BYTHE OWNER OR
BY OTHERS ACTING THROUGH THE OWNER
FREEZING CONDITIONS
IN LOCATIONS SUBJECTTO FREEZING CONDITIONS,
IT ISTHE OWNERS RESPONSIBILITY TO PROVIDE HEATAND
ADEQUATE INSULATION THROUGHOUT WET PIPE SPRINKLER
SYSTEM AREAS AND IN ENCLOSURES FOR DRY PIPE AND
OTHER TYPES OF VALVES CONTROLLING WATER SUPPLIES TO
SPRINKLER SYSTEMS.
I have reviewed these plans and
certify that they comply with the
adopted N FPA standards.
Nicet Name Corey Thompson
NICET Level IV 116184
Date of Review 07/07/22
Signature
❑AS-BUILT®SUBMITTAL❑ OTHER
REVISIONS
NO.
DATE
DESCRIPTION
07/07/22
FOR APPROVAL
4
CLLLLLLLLL
EL00000
0
N
N
N
NEEEN
E222
Q
N
7
7
7
7
CLWW
CL
aacn�
0
V
W
(0
(0
(0
(0
ILL
6
6
6
6
�
Y
iC
0)
J
C
M
0
N
0)
II
0
L
rC^L
VJ
(0
(O
(O
(O
75
0
0
0
0
a�
of
0�
IY
O
u-
d
U-
U-
LL
u-
u-
u-
Z_
v
LID
N
N
I6
f6
N
O
E
DRAWN BY
SEAN SMALL
3-D FIRE PROJECT NUMBER
4CO093
L
U)
c
X
W
M
,O
t�
❑
N
00
♦"'
a.
o
m
r
z
x
LL
000
oWC
[+M
PRINT DATE
07/07/22
FP-02
Hydraulic Information
Remote Area 1
OCCUPANCY CLASSIFICATION
Light Hazard
DENSITY (gpmlft2)
0.10 for 1500ft2 (Actual 1337ft2)
QUICK RESPONSE REDUCTION
14'-7 Ceiling (33.1 %) 1003ft2
TOTAL HOSE STREAMS
100.00
TOTAL HEADS FLOWING
12
K-FACTOR
5.6
TOTAL WATER REQUIRED
296.13
TOTAL PRESSURE REQUIRED
52.674
BASE of RISER (gpm)
296.13
BASE of RISER (psi)
52.674
SAFETY MARGIN (psi)
+26.971 (33.9%)
r
M�
W
r
N
E7
N
r
Z0
I -0 %2 U -0 %2 3 U -0 go
COMBUSTIBLE CONCEALED SPACE SPRINKLER PLAN
1 0 2 4
SCALE 1/4" = V-0"
114" = V-0
Idaho Falls, ID
Tel. 208-881-5414
Idaho License Number: FPSC-08
Sean.SmalI@3Dfire.us
OWNERSHIP OF DOCUMENTS
ALL DRAWINGS, SPECIFICATIONS, AND OTHER WORK PRODUCT
OF 3-D FORTH IS PROJECTARE INSTRUMENTS OF SERVICE
FOR THIS PROJECT ONLY AND SHALL REMAIN THE PROPERTY
OF 3-D W NETHER THE PROJECT IS COMPLETED OR NOT.
REUSE OF ANY OF THE INSTRUMENTS OF SERVICE, BY THE
OWNER OR EXTENSIONS OF THE PROJECT WITHOUT WRITTEN
PERMISSION OF 3-D SHALL BE ATTHE OWNER'S RISKAND THE
OWNER AGREES TO DEFEND, INDEMNIFY, AND HOLD
HARMLESS 3-D FROM ALL CLAIMS, DAMAGES, AND EXPENSES
INCLUDING ATTORNEYS' FEESARISING OUT OF UNAUTHORIZED
REUSE OF THE INSTRUMENTS OF SERVICE BYTHE OWNER OR
BY OTHERS ACTING THROUGH THE OWNER
FREEZING CONDITIONS
IN LOCATIONS SUBJECTTO FREEZING CONDITIONS,
IT ISTHE OWNERS RESPONSIBILITY TO PROVIDE HEATAND
ADEQUATE INSULATION THROUGHOUT WET PIPE SPRINKLER
SYSTEM AREAS AND IN ENCLOSURES FOR DRY PIPE AND
OTHER TYPES OF VALVES CONTROLLING WATER SUPPLIES TO
SPRINKLER SYSTEMS.
I have reviewed these plans and
certify that they comply with the
adopted N FPA standards.
Nicet Name Corey Thompson
NICET Level IV 116184
Date of Review 07/07/22
Signature
❑AS-BUILT®SUBMITTAL❑ OTHER
REVISIONS
NO.
DATE
DESCRIPTION
07/07/22
FOR APPROVAL
4
CLLLLLLLLL
EL00000
0
N
N
N
NEEEN
E222
Q
N
7
7
7
7
CL
W
W
CL
aacn�
0
V
W
(0
(0
(0
(0
ILL
6
6
6
6
�
Y
iC
0)
J
C
M
0
N
0)
II
0
L
rC^L
VJ
(0
(O
(O
(O
75
0
0
0
0
a�
of
0�
IY
O
u-
d
U-
U-
LL
u-
u-
u-
Z
I
LID
of
Q.
Q.
N
N
I6
f6
N
O
E
DRAWN BY
SEAN SMALL
3-D FIRE PROJECT NUMBER
4CO093
L
U)
c
X
W
M
,O
t�
❑
N
00
♦"'
a.
o
m
r
z
x
LL
000
oWC
[+M
PRINT DATE
07/07/22
FP-03