HomeMy WebLinkAboutINSPECTION TICKET - 22-00352 - 476 Reed St - Short Term RentalInspection
Ticket
Short Term Rental Life Safety Inspection on 05/27/2022: FAIL
Permit Number: 22-00352Permit Details
Short Term Rental Registration
Permit Issued Date: 476 Reed St
476 Reed St - Short Term Rental
Inspection Details
larry.beesley@rexburg.org
Inspected By: Larry Beesley
Short Term Rental Life Safety Inspection on 05/27/2022: FAIL
D ESCRIPTIO N CO M M EN TS STATUS
Hand Rail 34-38" high? - req'd with 4 or more
risers continuous top to bottom
YES
Guardrail on anything 30" above? (36" duplex,
42" on 3 or more units)
YES
Electrical wiring protected, covers installed, no
cords for permanent wiring
YES
Kitchen - GFCI on countertop areas YES
Bathroom - GFCI (any outlets in bathroom)YES
Bathroom - Fan or window?YES
Bedroom - Smoke detector installed and
functional?
YES
Bedroom - Egress Window 20"Wx24"H min.
w/5.7 sf and max 44' above floor to sill
YES
Hall - Min. width 36", lighting YES
Electrical - GFCI receptacles outside?YES
Is the house number clearly displayed?NO
Kitchen - Fire extinguisher (class 2A10BC
minimum), installed in plain sight
NO
Hall - Functional smoke detector and CO
detector?
Move the smoke CO detector from one of the
bedrooms to the hallway.
NO
Hall - Stairs handrail & headroom (6'8" min.)N/A
Structural Components?N/A
Parking COMPLETED
Inspector Comments
Call Anna Nelson in the morning to set up time for inspection. 206-1951
Install the fire extinguisher and the house numbers and move the smoke detector an CO detector as needed. Take
pitchers and send to me or call for a re inspection. Thanks
Final Inspections still to be completed Please call hotline 208-372-2344 to schedule final inspections when ready