HomeMy WebLinkAboutINSPECTION TICKET - 22-00352 - 476 Reed St - Short Term RentalInspection Ticket Short Term Rental Life Safety Inspection on 05/27/2022: FAIL Permit Number: 22-00352Permit Details Short Term Rental Registration Permit Issued Date: 476 Reed St 476 Reed St - Short Term Rental Inspection Details larry.beesley@rexburg.org Inspected By: Larry Beesley Short Term Rental Life Safety Inspection on 05/27/2022: FAIL D ESCRIPTIO N CO M M EN TS STATUS Hand Rail 34-38" high? - req'd with 4 or more risers continuous top to bottom YES Guardrail on anything 30" above? (36" duplex, 42" on 3 or more units) YES Electrical wiring protected, covers installed, no cords for permanent wiring YES Kitchen - GFCI on countertop areas YES Bathroom - GFCI (any outlets in bathroom)YES Bathroom - Fan or window?YES Bedroom - Smoke detector installed and functional? YES Bedroom - Egress Window 20"Wx24"H min. w/5.7 sf and max 44' above floor to sill YES Hall - Min. width 36", lighting YES Electrical - GFCI receptacles outside?YES Is the house number clearly displayed?NO Kitchen - Fire extinguisher (class 2A10BC minimum), installed in plain sight NO Hall - Functional smoke detector and CO detector? Move the smoke CO detector from one of the bedrooms to the hallway. NO Hall - Stairs handrail & headroom (6'8" min.)N/A Structural Components?N/A Parking COMPLETED Inspector Comments Call Anna Nelson in the morning to set up time for inspection. 206-1951 Install the fire extinguisher and the house numbers and move the smoke detector an CO detector as needed. Take pitchers and send to me or call for a re inspection. Thanks Final Inspections still to be completed Please call hotline 208-372-2344 to schedule final inspections when ready Page 1 of 1