HomeMy WebLinkAboutSAVANNAH SHORT LOAD FORM - 22-00242 - 753 S 2470 W - New SFR.pdfCalculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Sep-23 15:06:57 Rig ht-Su ite® U niv er sal 20 19 19 .0.13 RSU2 0477 Page 1 S:\High Country\Wrightsoft\SF6B14 Huntington.rup Calc = MJ8 House faces: NW SF6B14Job:Load Short Form Date:Entire House Vince ByramBy: Huntinton PlanPlan:Kartchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 Project Information Cody Puzey, Kartchner HomesFor: 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Design Information InfiltrationClgHtg SimplifiedMethod89-6Outside db (°F) AverageConstruction quality7568Inside db (°F) 0Fireplaces1474Design TD (°F) H-Daily range 5050Inside humidity (%) -3157Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Lennox Make Lennox Trade LENNOX Trade LENNOX Model ML195UH070XP36B-*Cond 13ACXN030-230-** AHRI ref 4805339 Coil CH35-36C++TDR+TXV AHRI ref 7623033 Efficiency 95 AFUE Efficiency 11.0 EER, 13 SEER Heating input Btuh66000 Sensible cooling Btuh20300 Heating output Btuh64000 Latent cooling Btuh8700 Temperature rise °F63 Total cooling Btuh29000 Actual air flow cfm1100 Actual air flow cfm967 Air flow factor cfm/Btuh0.025 Air flow factor cfm/Btuh0.063 Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 1.00 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Room7 320 6985 1109 172 69 Room9 288 4865 2161 120 135 Room11 162 1527 843 38 53 Room12 165 3733 1763 92 110 Room14 60 810 124 20 8 Room15 180 4254 1325 105 83 Room16 210 2900 1223 72 77 Room18 363 5399 1683 133 105 Room5 432 7809 2469 193 155 Room6 288 5328 2579 131 162 Room1 105 987 159 24 10 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Sep-23 15:06:57 Rig ht-Su ite® U niv er sal 20 19 19 .0.13 RSU2 0477 Page 2 S:\High Country\Wrightsoft\SF6B14 Huntington.rup Calc = MJ8 House faces: NW Entire House d 2573 44596 15438 1100 967 Other equip loads 3617 684 Equip. @ 0.94 RSM 15155 Latent cooling 0 TOTALS 2573 48212 15155 1100 967 2022-Sep-23 15:06:57 Rig ht-Su ite® U niv er sal 20 19 19 .0.13 RSU2 0477 Page 1 S:\High Country\Wrightsoft\SF6B14 Huntington.rup Calc = MJ8 House faces: NW SF6B14Job:Building Analysis Date:Entire House Vince ByramBy: Huntinton PlanPlan:Kartchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 Project Information Cody Puzey, Kartchner HomesFor: 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Design Conditions Location:CoolingHeatingIndoor: 7568Indoor temp era ture (°F)Idaho Falls, ID, US 1474Design TD (°F)ft4741Elevation: 5050Relative humidity (%)°N44Latitude:Outdoor:-31.557.0Moisture difference (gr/lb)CoolingHeating Infiltration:89-6Dry bul b (°F) SimplifiedMethod)H(34-Da ily ra nge (°F) AverageConstruction quality60-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing OtherCeilings Floors Infiltration Ventilation % of loadBtuhBtuh/ft²Component 39.0188277.6Walls 15.6751124.3Glazing 0.523311.1Doors 4.722691.5Ceilings 10.751643.43.4Floors 22.0105913.8Infiltration 00Ducts 00Piping 00Humidification 7.53617Ventilation0Adjustments 100.048212Total Cooling Walls Glazing Other Ceilings Infiltration Internal Gains Ventilation % of loadBtuhBtuh/ft²Component 11.518570.7Walls 53.9868528.1Glazing 0.4582.8Doors 8.012880.8Ceilings 1.11730.1Floors 6.410260.4Infiltration 00Ducts 4.2684Ventilation 14.62350Internal gains 00Blower 0Adjustments 100.016122Total Latent Cooling Load = 0 Btuh Overall U-va lue = 0.0 78 Btuh/ft²-°F Data entries checked. 2022-Sep-23 15:06:57 Rig ht-Su ite® U niv er sal 20 19 19 .0.13 RSU2 0477 Page 1 S:\High Country\Wrightsoft\SF6B14 Huntington.rup Calc = MJ8 House faces: NW SF6B14Job:Component Constructions Date:Entire House Vince ByramBy: Huntinton PlanPlan:Kartchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 Project Information Cody Puzey, Kartchner HomesFor: 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Design Conditions Location:CoolingHeatingIndoor: 7568Indoor temp era ture (°F)Idaho Falls, ID, US 1474Design TD (°F)ft4741Elevation: 5050Relative humidity (%)°N44Latitude: Outdoor:-31.557.0Moisture difference (gr/lb)CoolingHeating Infiltration:89-6Dry bul b (°F) SimplifiedMethod)H(34-Da ily ra nge (°F) AverageConstruction quality60-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls Frm wall, vnl ext, 3/8" wood shth, r-22 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 1660.4716794.8122.00.065349ne 2661.09269311.122.00.150243ne 1660.4716844.8122.00.065350se 3151.09319711.122.00.150288se 1560.4715794.8122.00.065328sw 2671.09270511.122.00.150244sw 1800.4718284.8122.00.065380nw 3421.09346311.122.00.150312nw 18570.74188277.5522.00.1502494all Partitions (none) Windows 61C: 61C; NFRC rated (SHGC=0.30)68522.873324.400.33030ne 176822.8189024.400.33077ne 69428.958624.400.33024se 207228.9175024.400.33072sw 220728.9186424.400.33076sw 742626.6682324.400.330279all Double Pane:88329.468822.900.31030se Doors metal: Door, mtl pur core type 582.7823311.16.00.15021ne Ceilings 16B-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 1/2" gypsum board int fnsh 12880.8422691.4850.00.0201533 Floors 19A-30bscp: Part floor, carpet flr fnsh, r-30 ins, frm flr, 12" thkns, 5/8" gypsum board int fnsh 1730.409142.1130.00.034433 2022-Sep-23 15:06:57 Rig ht-Su ite® U niv er sal 20 19 19 .0.13 RSU2 0477 Page 2 S:\High Country\Wrightsoft\SF6B14 Huntington.rup Calc = MJ8 House faces: NW 22B-10cpm: Bg floor, heavy dry or light damp soil, on grade depth, r-10 edge ins, carpet flr fnsh 0015226.310.00.3556 00409826.310.00.355156 00425026.310.00.355162all Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Sep-23 15:06:57 Rig ht-Su ite® U niv er sal 20 19 19 .0.13 RSU2 0477 Page 1 S:\High Country\Wrightsoft\SF6B14 Huntington.rup Calc = MJ8 House faces: NW SF6B14Job:Project Summary Date:Entire House Vince ByramBy: Huntinton PlanPlan:Kartchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 Project Information Cody Puzey, Kartchner HomesFor:3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Notes: Design Information Idaho Falls, ID, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F-6 Outside db °F89Inside db °F68 Inside db °F75 Design TD °F74 Design TD °F14Daily range H Relative humidity %50Moisture difference gr/lb-31 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh44596 Structure Btuh15438 Ducts Btuh0 Ducts Btuh0Central vent (53 cfm)3617 Btuh Central vent (53 cfm)Btuh684 Outside air Outside airHumidificationBtuh0Blower Btuh0 Piping Btuh0Equipment load Btuh48212 Use manufacturer's data n Rate/swing multiplier 0.94InfiltrationEquipment sensible load Btuh15155 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh-427 Ducts Btuh0Central vent (53 cfm)Btuh-951 CoolingHeating Outside air25732573Area (ft²)Equipment latent load Btuh0 2266422664Volume (ft³)Air changes/hour 0.210.41 Equipment Total Load (Sen+Lat)Btuh15155 Equiv. AVF (cfm)79155 Req. total capacity at 0.70 SHR ton1.8 Heating Equipment Summary Cooling Equipment Summary Make Lennox Make LennoxTradeLENNOXTradeLENNOX Model ML195UH070XP36B-*Cond 13ACXN030-230-**AHRI ref 4805339 Coil CH35-36C++TDR+TXV AHRI ref 7623033Efficiency95 AFUE Efficiency 11.0 EER, 13 SEER Heating input Btuh66000 Sensible cooling Btuh20300Heating output Btuh64000 Latent cooling Btuh8700 Temperature rise °F63 Total cooling Btuh29000Actual air flow cfm1100 Actual air flow cfm967 Air flow factor cfm/Btuh0.025 Air flow factor cfm/Btuh0.063Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 1.00 2022-Sep-23 15:06:57 Rig ht-Su ite® U niv er sal 20 19 19 .0.13 RSU2 0477 Page 1 S:\High Country\Wrightsoft\SF6B14 Huntington.rup Calc = MJ8 House faces: NW SF6B14Job:AED Assessment Date:Entire House Vince ByramBy: Huntinton PlanPlan:Kartchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 Project Information Cody Puzey, Kartchner HomesFor: 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Design Conditions Location:CoolingHeatingIndoor: 7568Indoor temp era ture (°F)Idaho Falls, ID, US 1474Design TD (°F)ft4741Elevation: 5050Relative humidity (%)°N44Latitude: Outdoor:-31.557.0Moisture difference (gr/lb)CoolingHeating Infiltration:89-6Dry bul b (°F) )H(34-Da ily ra nge (°F) 60-We t bu lb (°F) 7.515.0Wind speed (mph) Test for Adequate Exposure Diversity Hourly Glazing Load Hourly Average AED limitGlazing load (Btuh)Hour of Day 0 1,000 2,000 3,000 4,000 5,000 6,000 7,000 8,000 9,000 10,000 11,000 8 9 10 11 12 13 14 15 16 17 18 19 20 Maximum hourly glazing load exceeds average by 34.7%. House does not have adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 377 Btuh (PFG - 1.3*AFG) Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Sep-23 15:06:57Right-Su ite® U niv er sal 20 19 19 .0.13 RSU2 0477 Page 1S:\High Country\Wrightsoft\SF6B14 Huntington.rup Calc = MJ8 House faces: NW SF6B14Job:Right-J® W or ksheet Date:Entire House Vince ByramBy:Huntinton PlanPlan:Kartchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 1 Room name Entire House Room7 2 Exposed wall 314.0 ft 56.0 ft 3 Room height 8.8 dft 10.0 heat/coolft 4 Room dimensions ft20.0x16.0 5 Room area 2573.0 f t²320.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nene 4.814.81 0.470.47 400 349 1679 166 160 109 524 52 .GG 61C61C 0.3300.330 nene 24.4224.42 22.8422.84 30 0 733 685 30 0 733 685 .DD metalmetal 0.1500.150 nene 11.1011.10 2.782.78 21 21 233 58 21 21 233 58 .WW Frm wall, vnl ext, 3 0.150Frm wall, vnl ext, 3 0.150 nene 11.1011.10 1.091.09 320 243 2693 266 0 0 0 0 1 1 GG 61C61C 0.3300.330 nene 24.4224.42 22.8422.84 77 0 1890 1768 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 sese 4.814.81 0.470.47 380 350 1683 166 200 200 962 95 GG Double PaneDouble Pane 0.3100.310 sese 22.9422.94 29.4429.44 30 0 688 883 0 0 0 0 WW Frm wall, vnl ext, 3 0.150Frm wall, vnl ext, 3 0.150 sese 11.1011.10 1.091.09 312 288 3197 315 0 0 0 0 GG 61C61C 0.3300.330 sese 24.4224.42 28.9128.91 24 0 586 694 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 swsw 4.814.81 0.470.47 400 328 1579 156 0 0 0 0 GG 61C61C 0.3300.330 swsw 24.4224.42 28.9128.91 72 0 1750 2072 0 0 0 0 WW Frm wall, vnl ext, 3 0.150Frm wall, vnl ext, 3 0.150 swsw 11.1011.10 1.091.09 320 244 2705 267 0 0 0 0 GG 61C61C 0.3300.330 swsw 24.4224.42 28.9128.91 76 0 1864 2207 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nwnw 4.814.81 0.470.47 380 380 1828 180 200 200 962 95 WW Frm wall, vnl ext, 3 0.150Frm wall, vnl ext, 3 0.150 nwnw 11.1011.10 1.091.09 312 312 3463 342 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.481.48 0.840.84 1533 1533 2269 1288 0 0 0 0 FF 19A-30bscp19A-30bscp 0.0340.034 --2.112.11 0.400.40 433 433 914 173 0 0 0 0 FF 22B-10cpm22B-10cpm 0.3550.355 --26.2726.27 0.000.00 60 6 152 0 0 0 0 0 FF 22B-10cpm22B-10cpm 0.3550.355 --26.2726.27 0.000.00 1040 156 4098 0 320 56 1471 0 6 c) AED excursion 377 -79 Envelope loss/gain 34004 12062 4885 905 12 a)Infiltration 10591 1026 2100 204 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 5 1150 0 0 Appliances/other 1200 0 Subtotal (lines 6 to 13)44596 15438 6985 1109 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 44596 15438 6985 1109 15 Duct loads 0%0%0 0 -0%0%0 0 Total room load 44596 15438 6985 1109 Air required (cfm)Air required (cfm)1100 967 172 69 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Sep-23 15:06:57Right-Su ite® U niv er sal 20 19 19 .0.13 RSU2 0477 Page 2S:\High Country\Wrightsoft\SF6B14 Huntington.rup Calc = MJ8 House faces: NW SF6B14Job:Right-J® W or ksheet Date:Entire House Vince ByramBy:Huntinton PlanPlan:Kartchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 1 Room name Room9 Room11 2 Exposed wall 34.0 ft 9.0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft18.0x16.0 ft18.0x9.0 5 Room area 288.0 f t²162.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nene 4.814.81 0.470.47 0 0 0 0 0 0 0 0 .GG 61C61C 0.3300.330 nene 24.4224.42 22.8422.84 0 0 0 0 0 0 0 0 .DD metalmetal 0.1500.150 nene 11.1011.10 2.782.78 0 0 0 0 0 0 0 0 .WW Frm wall, vnl ext, 3 0.150Frm wall, vnl ext, 3 0.150 nene 11.1011.10 1.091.09 0 0 0 0 0 0 0 0 1 1 GG 61C61C 0.3300.330 nene 24.4224.42 22.8422.84 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 sese 4.814.81 0.470.47 0 0 0 0 0 0 0 0 GG Double PaneDouble Pane 0.3100.310 sese 22.9422.94 29.4429.44 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.150Frm wall, vnl ext, 3 0.150 sese 11.1011.10 1.091.09 0 0 0 0 0 0 0 0 GG 61C61C 0.3300.330 sese 24.4224.42 28.9128.91 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 swsw 4.814.81 0.470.47 0 0 0 0 0 0 0 0 GG 61C61C 0.3300.330 swsw 24.4224.42 28.9128.91 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.150Frm wall, vnl ext, 3 0.150 swsw 11.1011.10 1.091.09 128 98 1088 107 72 56 618 61 GG 61C61C 0.3300.330 swsw 24.4224.42 28.9128.91 30 0 733 867 16 0 399 472 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nwnw 4.814.81 0.470.47 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.150Frm wall, vnl ext, 3 0.150 nwnw 11.1011.10 1.091.09 144 144 1598 158 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.481.48 0.840.84 288 288 426 242 162 162 240 136 FF 19A-30bscp19A-30bscp 0.0340.034 --2.112.11 0.400.40 0 0 0 0 0 0 0 0 FF 22B-10cpm22B-10cpm 0.3550.355 --26.2726.27 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10cpm22B-10cpm 0.3550.355 --26.2726.27 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion 228 148 Envelope loss/gain 3845 1602 1257 817 12 a)Infiltration 1020 99 270 26 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 2 460 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)4865 2161 1527 843 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 4865 2161 1527 843 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 4865 2161 1527 843 Air required (cfm)Air required (cfm)120 135 38 53 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Sep-23 15:06:57Right-Su ite® U niv er sal 20 19 19 .0.13 RSU2 0477 Page 3S:\High Country\Wrightsoft\SF6B14 Huntington.rup Calc = MJ8 House faces: NW SF6B14Job:Right-J® W or ksheet Date:Entire House Vince ByramBy:Huntinton PlanPlan:Kartchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 1 Room name Room12 Room14 2 Exposed wall 26.0 ft 5.0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft11.0x15.0 ft5.0x12.0 5 Room area 165.0 f t²60.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nene 4.814.81 0.470.47 0 0 0 0 0 0 0 0 .GG 61C61C 0.3300.330 nene 24.4224.42 22.8422.84 0 0 0 0 0 0 0 0 .DD metalmetal 0.1500.150 nene 11.1011.10 2.782.78 0 0 0 0 0 0 0 0 .WW Frm wall, vnl ext, 3 0.150Frm wall, vnl ext, 3 0.150 nene 11.1011.10 1.091.09 0 0 0 0 0 0 0 0 1 1 GG 61C61C 0.3300.330 nene 24.4224.42 22.8422.84 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 sese 4.814.81 0.470.47 0 0 0 0 0 0 0 0 GG Double PaneDouble Pane 0.3100.310 sese 22.9422.94 29.4429.44 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.150Frm wall, vnl ext, 3 0.150 sese 11.1011.10 1.091.09 88 88 977 96 0 0 0 0 GG 61C61C 0.3300.330 sese 24.4224.42 28.9128.91 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 swsw 4.814.81 0.470.47 0 0 0 0 0 0 0 0 GG 61C61C 0.3300.330 swsw 24.4224.42 28.9128.91 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.150Frm wall, vnl ext, 3 0.150 swsw 11.1011.10 1.091.09 120 90 999 99 0 0 0 0 GG 61C61C 0.3300.330 swsw 24.4224.42 28.9128.91 30 0 733 867 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nwnw 4.814.81 0.470.47 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.150Frm wall, vnl ext, 3 0.150 nwnw 11.1011.10 1.091.09 0 0 0 0 40 40 444 44 CC 16B-50ad16B-50ad 0.0200.020 --1.481.48 0.840.84 165 165 244 139 60 60 89 50 FF 19A-30bscp19A-30bscp 0.0340.034 --2.112.11 0.400.40 0 0 0 0 60 60 127 24 FF 22B-10cpm22B-10cpm 0.3550.355 --26.2726.27 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10cpm22B-10cpm 0.3550.355 --26.2726.27 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion 256 -9 Envelope loss/gain 2953 1457 659 109 12 a)Infiltration 780 76 150 15 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 1 230 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)3733 1763 810 124 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 3733 1763 810 124 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 3733 1763 810 124 Air required (cfm)Air required (cfm)92 110 20 8 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Sep-23 15:06:57Right-Su ite® U niv er sal 20 19 19 .0.13 RSU2 0477 Page 4S:\High Country\Wrightsoft\SF6B14 Huntington.rup Calc = MJ8 House faces: NW SF6B14Job:Right-J® W or ksheet Date:Entire House Vince ByramBy:Huntinton PlanPlan:Kartchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 1 Room name Room15 Room16 2 Exposed wall 27.0 ft 15.0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft15.0x12.0 ft210.0x1.0 5 Room area 180.0 f t²210.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nene 4.814.81 0.470.47 0 0 0 0 0 0 0 0 .GG 61C61C 0.3300.330 nene 24.4224.42 22.8422.84 0 0 0 0 0 0 0 0 .DD metalmetal 0.1500.150 nene 11.1011.10 2.782.78 0 0 0 0 0 0 0 0 .WW Frm wall, vnl ext, 3 0.150Frm wall, vnl ext, 3 0.150 nene 11.1011.10 1.091.09 96 66 733 72 104 74 821 81 1 1 GG 61C61C 0.3300.330 nene 24.4224.42 22.8422.84 30 0 733 685 30 0 733 685 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 sese 4.814.81 0.470.47 0 0 0 0 0 0 0 0 GG Double PaneDouble Pane 0.3100.310 sese 22.9422.94 29.4429.44 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.150Frm wall, vnl ext, 3 0.150 sese 11.1011.10 1.091.09 0 0 0 0 8 8 89 9 GG 61C61C 0.3300.330 sese 24.4224.42 28.9128.91 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 swsw 4.814.81 0.470.47 0 0 0 0 0 0 0 0 GG 61C61C 0.3300.330 swsw 24.4224.42 28.9128.91 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.150Frm wall, vnl ext, 3 0.150 swsw 11.1011.10 1.091.09 0 0 0 0 0 0 0 0 GG 61C61C 0.3300.330 swsw 24.4224.42 28.9128.91 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nwnw 4.814.81 0.470.47 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.150Frm wall, vnl ext, 3 0.150 nwnw 11.1011.10 1.091.09 120 120 1332 131 8 8 89 9 CC 16B-50ad16B-50ad 0.0200.020 --1.481.48 0.840.84 180 180 266 151 210 210 311 176 FF 19A-30bscp19A-30bscp 0.0340.034 --2.112.11 0.400.40 180 180 380 72 193 193 408 77 FF 22B-10cpm22B-10cpm 0.3550.355 --26.2726.27 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10cpm22B-10cpm 0.3550.355 --26.2726.27 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -95 -88 Envelope loss/gain 3444 1017 2450 949 12 a)Infiltration 810 79 450 44 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 1 230 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13)4254 1325 2900 1223 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 4254 1325 2900 1223 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 4254 1325 2900 1223 Air required (cfm)Air required (cfm)105 83 72 77 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Sep-23 15:06:57Right-Su ite® U niv er sal 20 19 19 .0.13 RSU2 0477 Page 5S:\High Country\Wrightsoft\SF6B14 Huntington.rup Calc = MJ8 House faces: NW SF6B14Job:Right-J® W or ksheet Date:Entire House Vince ByramBy:Huntinton PlanPlan:Kartchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 1 Room name Room18 Room5 2 Exposed wall 35.0 ft 66.0 ft 3 Room height 8.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft363.0x1.0 ft18.0x24.0 5 Room area 363.0 f t²432.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nene 4.814.81 0.470.47 0 0 0 0 240 240 1154 114 .GG 61C61C 0.3300.330 nene 24.4224.42 22.8422.84 0 0 0 0 0 0 0 0 .DD metalmetal 0.1500.150 nene 11.1011.10 2.782.78 0 0 0 0 0 0 0 0 .WW Frm wall, vnl ext, 3 0.150Frm wall, vnl ext, 3 0.150 nene 11.1011.10 1.091.09 120 103 1139 112 0 0 0 0 1 1 GG 61C61C 0.3300.330 nene 24.4224.42 22.8422.84 17 0 425 397 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 sese 4.814.81 0.470.47 0 0 0 0 0 0 0 0 GG Double PaneDouble Pane 0.3100.310 sese 22.9422.94 29.4429.44 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.150Frm wall, vnl ext, 3 0.150 sese 11.1011.10 1.091.09 160 136 1510 149 0 0 0 0 GG 61C61C 0.3300.330 sese 24.4224.42 28.9128.91 24 0 586 694 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 swsw 4.814.81 0.470.47 0 0 0 0 240 218 1050 104 GG 61C61C 0.3300.330 swsw 24.4224.42 28.9128.91 0 0 0 0 22 0 529 626 WW Frm wall, vnl ext, 3 0.150Frm wall, vnl ext, 3 0.150 swsw 11.1011.10 1.091.09 0 0 0 0 0 0 0 0 GG 61C61C 0.3300.330 swsw 24.4224.42 28.9128.91 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nwnw 4.814.81 0.470.47 0 0 0 0 180 180 866 85 WW Frm wall, vnl ext, 3 0.150Frm wall, vnl ext, 3 0.150 nwnw 11.1011.10 1.091.09 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.481.48 0.840.84 363 363 537 305 0 0 0 0 FF 19A-30bscp19A-30bscp 0.0340.034 --2.112.11 0.400.40 0 0 0 0 0 0 0 0 FF 22B-10cpm22B-10cpm 0.3550.355 --26.2726.27 0.000.00 60 6 152 0 0 0 0 0 FF 22B-10cpm22B-10cpm 0.3550.355 --26.2726.27 0.000.00 0 0 0 0 432 66 1734 0 6 c) AED excursion -76 100 Envelope loss/gain 4349 1582 5333 1029 12 a)Infiltration 1050 102 2475 240 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 1200 Subtotal (lines 6 to 13)5399 1683 7809 2469 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 5399 1683 7809 2469 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 5399 1683 7809 2469 Air required (cfm)Air required (cfm)133 105 193 155 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Sep-23 15:06:57Right-Su ite® U niv er sal 20 19 19 .0.13 RSU2 0477 Page 6S:\High Country\Wrightsoft\SF6B14 Huntington.rup Calc = MJ8 House faces: NW SF6B14Job:Right-J® W or ksheet Date:Entire House Vince ByramBy:Huntinton PlanPlan:Kartchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 1 Room name Room6 Room1 2 Exposed wall 34.0 ft 7.0 ft 3 Room height 10.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft18.0x16.0 ft7.0x15.0 5 Room area 288.0 f t²105.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nene 4.814.81 0.470.47 0 0 0 0 0 0 0 0 .GG 61C61C 0.3300.330 nene 24.4224.42 22.8422.84 0 0 0 0 0 0 0 0 .DD metalmetal 0.1500.150 nene 11.1011.10 2.782.78 0 0 0 0 0 0 0 0 .WW Frm wall, vnl ext, 3 0.150Frm wall, vnl ext, 3 0.150 nene 11.1011.10 1.091.09 0 0 0 0 0 0 0 0 1 1 GG 61C61C 0.3300.330 nene 24.4224.42 22.8422.84 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 sese 4.814.81 0.470.47 180 150 721 71 0 0 0 0 GG Double PaneDouble Pane 0.3100.310 sese 22.9422.94 29.4429.44 30 0 688 883 0 0 0 0 WW Frm wall, vnl ext, 3 0.150Frm wall, vnl ext, 3 0.150 sese 11.1011.10 1.091.09 0 0 0 0 56 56 622 61 GG 61C61C 0.3300.330 sese 24.4224.42 28.9128.91 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 swsw 4.814.81 0.470.47 160 110 529 52 0 0 0 0 GG 61C61C 0.3300.330 swsw 24.4224.42 28.9128.91 50 0 1221 1446 0 0 0 0 WW Frm wall, vnl ext, 3 0.150Frm wall, vnl ext, 3 0.150 swsw 11.1011.10 1.091.09 0 0 0 0 0 0 0 0 GG 61C61C 0.3300.330 swsw 24.4224.42 28.9128.91 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nwnw 4.814.81 0.470.47 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.150Frm wall, vnl ext, 3 0.150 nwnw 11.1011.10 1.091.09 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.481.48 0.840.84 0 0 0 0 105 105 155 88 FF 19A-30bscp19A-30bscp 0.0340.034 --2.112.11 0.400.40 0 0 0 0 0 0 0 0 FF 22B-10cpm22B-10cpm 0.3550.355 --26.2726.27 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10cpm22B-10cpm 0.3550.355 --26.2726.27 0.000.00 288 34 893 0 0 0 0 0 6 c) AED excursion 3 -11 Envelope loss/gain 4053 2455 777 138 12 a)Infiltration 1275 124 210 20 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)5328 2579 987 159 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 5328 2579 987 159 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 5328 2579 987 159 Air required (cfm)Air required (cfm)131 162 24 10 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Sep-23 15:06:58 Rig ht-Su ite® U niv er sal 20 19 19 .0.13 RSU2 0477 Page 1 S:\High Country\Wrightsoft\SF6B14 Huntington.rup Calc = MJ8 House faces: NW SF6B14Job:Loads for Multiple Orientations Date:Entire House Vince ByramBy: Huntinton PlanPlan:Kartchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 Project Information Cody Puzey, Kartchner HomesFor: 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Design Conditions Location:CoolingHeatingIndoor: 7568Indoor temp era ture (°F)Idaho Falls, ID, US 1474Design TD (°F)ft4741Elevation: 5050Relative humidity (%)°N44Latitude: Outdoor:-31.557.0Moisture difference (gr/lb)CoolingHeating Infiltration:89-6Dry bul b (°F) )H(34-Da ily ra nge (°F) 60-We t bu lb (°F) 7.515.0Wind speed (mph) House North Northeast East Southeast South Southwest West Northwest Sensible Load (Btuh)16025 14742 12403 14876 15360 14487 12509 15155 Latent Load (Btuh)0 0 0 0 0 0 0 0 Total Load (Btuh)16025 14742 12403 14876 15360 14487 12509 15155 Heating AVF (cfm)1100 1100 1100 1100 1100 1100 1100 1100 Cooling AVF (cfm)967 967 967 967 967 967 967 967 Building Orientation Cooling Load Total Cooling Load (Btuh)Direction House faces 0 5000 10000 15000 20000 N NE E SE S SW W NW House faces NorthwestCurrent Orientation: House faces NorthHighest Cooling Load: Job #: SF6B14 Performed by Vince Byram for: Cody Puzey 3758 Yellowstones Hwy Idaho Falls, Id 83401 Phone: 208-529-2116 Kartchner 601 West 1700 South Logan, Utah 84321 Phone: 435-755-7080 Scale: 1 : 67 Page 1 Ri ght -Sui te® Uni v ersal 2 019 19.0.13 RSU20477 2022-Sep-23 15:07:15 ...rightsoft\SF6B14 Huntington.rup N Main Room5Room6 Room7 6" Mechanical Damper for Fresh Air 96 cfm81 cfm 86 cfm 96 cfm81 cfm 86 cfm 496 cfm 6 " 14x3.25 2-14x3.25 14x3.25 6 "6 " 6 " 6 "6 " 6 " 6 " 6 " 6 "6 " 4-14x3.25 6 " 6 " 6 " 20 x 8 2-14x3.25 6 " 12 x 8 20 x 8 Job #: SF6B14 Performed by Vince Byram for: Cody Puzey 3758 Yellowstones Hwy Idaho Falls, Id 83401 Phone: 208-529-2116 Kartchner 601 West 1700 South Logan, Utah 84321 Phone: 435-755-7080 Scale: 1 : 67 Page 2 Ri ght -Sui te® Uni v ersal 2 019 19.0.13 RSU20477 2022-Sep-23 15:07:15 ...rightsoft\SF6B14 Huntington.rup N 2nd floor Room9Room11 Room12 Room14 Room15Room16 Room18 Room1 67 cfm 105 cfm 120 cfm 153 cfm 77 cfm 24 cfm 67 cfm 53 cfm 110 cfm 20 cfm 105 cfm 188 cfm 77 cfm 135 cfm 2022-Sep-23 15:06:59 Rig ht-Su ite® U niv er sal 20 19 19 .0.13 RSU2 0477 Page 1 S:\High Country\Wrightsoft\SF6B14 Huntington.rup Calc = MJ8 House faces: NW SF6B14Job:Duct System Summary Date:Entire House Vince ByramBy: Huntinton PlanPlan:Kartchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 Project Information Cody Puzey, Kartchner HomesFor: 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 CoolingHeating External static pressure in H2O0.70in H2O0.70 Pressure losses in H2O0.34in H2O0.34 Available static pressure in H2O0.36in H2O0.36 Supply / return available pressure 0.269 / 0.091 in H2O in H2O0.269 / 0.091 Lowest friction rate in/100ft0.079in/100ft0.079 Actual air flow cfm967cfm1100 Total effective length (TEL)ft453 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm)(cfm)FR (in)(in)Matl Ln (ft)Ln (ft)Trunk st2325.013.0ShMt0x06.00.0791024987hRoom1 st2325.013.0ShMt0x06.00.0795338843cRoom11 st2325.013.0ShMt0x06.00.079110921763cRoom12 st1325.013.0ShMt0x06.00.079820810hRoom14 325.013.0ShMt0x06.00.079831054254hRoom15 st2325.013.0ShMt0x06.00.07977721223cRoom16 st2325.013.0ShMt0x06.00.07953672699hRoom18 st2325.013.0ShMt0x06.00.07953672699hRoom18-B st1325.013.0ShMt0x06.00.07977963904hRoom5 st2325.013.0ShMt0x06.00.07977963904hRoom5-A st2325.013.0ShMt0x06.00.07981661289cRoom6 st2325.013.0ShMt0x06.00.07981661289cRoom6-A st2325.013.0ShMt0x06.00.07935863493hRoom7 st2325.013.0ShMt0x06.00.07935863493hRoom7-A 325.013.0ShMt0x06.00.0791351202161cRoom9 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st1 Peak AVF 116 85 0.079 174 6.5 12x8 ShtMetl st2 Peak AVF 759 664 0.079 683 14.2 20x8 ShtMetl 2022-Sep-23 15:06:59 Rig ht-Su ite® U niv er sal 20 19 19 .0.13 RSU2 0477 Page 2 S:\High Country\Wrightsoft\SF6B14 Huntington.rup Calc = MJ8 House faces: NW Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in)(cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in)Matl Trunk rb3 0x 4960 386 115.0 0.079 393 11.1 4-3.25x14 4-10x36 SJSp rt1 rb8 0x 720 77 115.0 0.079 242 5.5 3.25x14 10x9 SJSp rt1 rb1 0x 1580 188 115.0 0.079 298 7.7 2-3.25x14 2-10x18 SJSp rb6 0x 1160 120 115.0 0.079 381 6.5 3.25x14 10x9 SJSp rt1 rb7 0x 1530 113 115.0 0.079 242 7.2 2-3.25x14 2-10x18 SJSp rt1 rb5 0x 1050 83 115.0 0.079 90 6.2 x14 12 ShMt Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk rt1 Peak AVF 837 696 0.079 754 14.9 20x8 ShtMetl