Loading...
HomeMy WebLinkAboutFIRE PROTECTION SUBMITTALS - 07-00367 - Burton Elementary School - AdditionState of Idaho DEPARTMENT OF INSURANCE Cs„ `BUTTCH" OTTER 700 West State Street, 3rd Floor Governor P.O. Box 83720 Boise, Idaho 83720-0043 Phone(208)334-4250 FAX # (208)334-4398 WILLIAM W. DEAL Director NLkM A. LARSON State Fire Marshal PLAN REVIEW FOR. FIRE SPRINKLER SYSTEMS PROJECT: V STREET ADDRESS: W - -IV CITY On bll FIRE PROTECTION CONTRACTOR: SN 1L- rvl� ADDRESS: i ? CITY: N a STATE: =pA ZTP: 3 6 87 PHONE NO: Zo if - yLb -0gu L FAX NO: - y &G — 78 S0 SIGNATURE ON PLAN: DATE ON PLAN: P r g DATE PLAN RECEIVED: DATE PLAN REVIEWED: Z—G—vif rrEITEM DEFICIENCY NOTED NOTE: SYs7EMS E%CEEDING 20 spitnu xRS IN SME SHALL BE CONSTANTLY SUPERVISED AT A CENTRAL LOCATION — LF.C. 903A • NOTE. IT isACs{1NOWLEDC�D THAT AN UNAPPROVED BACEFIAW PREVENTER IS INSTALLED PER THE DEMAND OF THE LOCAL WATER PURVEYER. DUE TO THE ffiGH PRUPORTED FAILURE RATE, STATE FIRE MARSHAL'S OFFICE. AND ITS PERSONNEL. DOES NOT APPROVE OF OR TAKE ANY RESPONS>SHdTY FOR THE BACEFLOW DEVICE. REVIEWED BY: LUH Enterprises PO Box 9 Fairfield, Idaho 83327 PLANS REVIEWER: Mel Fletcher Ph 208-764-2 37 Fax 208-764-2090 CC TO: Mark Larson Idaho Surveying & Rating File A.H.J. Q6 bWtl + kC' APPROVED - If deficiencies noted above are corrected and subject to a field inspection. DISAPPROVED - Resubmit with items noted * corrected. ADDITIONAL - Information requested 10-2005 Equal Opportunity Employer ' M .4,SHILO AUTOMATIC SPRINKLERS, Inc. QUALITY FIRE PROTECTION 1224 ELEVENTH AVE NORTH NAMPA, IDAHO 83687 FIRE PROTECTION SUBMITTALS FOR BURTON Elementary School West 7th South Rexburg, Idaho 83440 Date: January 18, 2007 SHILO Job #: 10-07051 PHONE (208) 442-0007 • (208) 466-0006 • Fax (208) 466-7890 • E-MAIL design@shilosprinkler.com SHILO AUTOMATIC SPRINKLERS, Inc. QUALITY FIRE PROTECTION 1224 ELEVENTH AVE NORTH NANTA, II)AHO 83687 1 . no 0 BURTON Elementary School West 7th South Rexburg, Idaho 83440 Date: January 18, 2007 SHILO Job #: 10-07051 PHONE (208) 442-0007 • (208) 466-0006 • Fax (208) 466-7890 • E-MAIL design@shilosprinkler.com i `a� * WE SUPPORT AND ENCOURAGE NICET CERTIFICATION SNILO AUTOMATIC SPRINKLERS, Inc. QUALITY FIRE PROTECTION „�.. 1224 ELEVENTH AVE NORTH NAMPA, H}AHO 83687 ARCHERmLYMAN ELEMENTARY SCHOOL INDEX HYDRAULIC CALCULATIONS SWAY BRACE CALCULATIONS WATER FLOW INFORMATION PRODUCT DATA SHOP DRAWINGS Phone (208) 442-0007 ® (208) 466-0006 ® Fax (208) 466-780 s E-MAIL design@shilosprinklerecorn }`' , * ;"' SHILO AUTOMATIC SPRINKLERS, Inc. t QUALITY FIRE PROTECTION 1224 ELEVENTH AVE NORTH NAMPA, IDAHO 83687 HYDRAULIC CALCULATIONS CALC AREA 1 Lillie Scales Fire Protection Design Email: design@shilosprinkler.com Phone (208) 442-0007 • (208) 466-0006 • Fax (208) 466-7890 • E-MAIL design@shilosprinkler.com Burton Elementary School Drawing Date:Jan 2008 1121108 11:38 HYDRAULIC DESIGN INFORMATION SHEET Job Name: Burton Elementary School Location: Madison School District West 7th South, Rexburg ID Drawing Date: Jan 2008 Remote Area Number: 1 Contractor: SHILO Automatic Sprinkler Telephone:208-466-0006 1224 Eleventh Avenue North Nampa, Idaho 83687 Designer: Design Dept Calculated By:SprinkCAD www.sprinkcad.com 451 N. Cannon Ave. Lansdale, PA 19446 Construction: Combustible Occupancy:School Reviewing Authorities:Rexburg Fire District, Owner SYSTEM DESIGN Code:NFPA 13 Hazard:Light System Type:WET Area of Sprinkler Oper. 948 sq ft1 Sprinkler or Nozzle Density (gpm/sq ft) 0.100 1 Make: TYCO Area per Sprinkler 168.0 sq ft1 Model: TY-FRB Hose Allowance Inside 0 gpm 1 K-Factor: 5.60 Hose Allowance Outside 100 gpm 1 Temperature Rating: 155 CALCULATION SUMMARY 11 Flowing Outlets gpm Required: 318.5 psi Required: 88.9 @ Source WATER SUPPLY Water Flow Test I Pump Data 1 Date of Test 01/17/2008 1 Rated Capacity 0 gpm 1 Static Pressure 95.0 psi Rated Pressure 0.0 psi 1 Residual Pres 30.0 psi Elevation 0 At a Flow of 4000 gpm Make: Elevation 0" Model: 1 Location: W 7th S & S 12th W, Rexburg Source of Information: Contractor Flow Test SYSTEM VOLUME 646 Gallons Notes: Burton Elementary School Drawing Date:Jan 2008 1121108 11:38 HYDRAULIC CALCULATION DETAILS HYDRAULIC FLOW LOSS QTY DESCRIPTION LENGTH C ID gpm psi TOTALS Hydr Ref W Required at Hyd Area 1 219 69.1 psi Elevation Change 17'0" 7.4 1 3" Grvd 90 Ell 7' 120 3.068 219 0.5 1 Pipe 3" 40x2l 13' 120 3.068 219 0.8 1 3" Grvd Other Valve Tyco 513 CHART LOSS 219 3.0 1 3" Grvd Butterfly Valve "BFV" 10' 120 3.068 219 0.6 1 3" Grvd Back Flow Valve Ames "200" CHART LOSS 219 3.4 1 3" Grvd Tee 15' 120 3.068 219 1.0 1 Pipe 3" 10x21 1' 120 3.260 219 0.0 Hydr Ref BOR Required at Base of Riser 219 85.6 psi Elevation Change 610" 2.6 1 Pipe 6" DIx18 C1 350 6' 140 6.338 219 0.0 1 6" MJ 90 Ell 14' 120 6.065 219 0.0 1 Pipe 6" C-900x2l 350' 150 6.300 219 0.4 2 6" MJ 45 Ell 14' 120 6.065 219 0.0 1 6" MJ Tee 30' 120 6.065 219 0.1 Hydr Ref M1 Required at City Main 219 88.8 psi Fixed Flow Outside Hose Allow. 100 gpm 1 Pipe 12" DIx18 Cl 350 2000' 140 12.578 319 0.2 1 12" MJ Tee 60' 120 11.938 319 0.0 Hydr Ref SRC Required at Source 319 88.9 psi Water Source 95.0 psi static, 30.0 psi residual @ 4000 gpm 319 gpm 94.4 psi SAFETY PRESSURE 5.5 psi Available Pressure of 94.4 psi Exceeds Required Pressure of 88.9 psi This is a safety margin of 5.5 psi or 6 % of Supply Maximum Water Velocity is 19.4 fps Burton Elementary School Drawing Date:Jan 2008 1121108 11:38 FITTING NAME TABLE ABBREV. NAME C ;M Coupling E 90' Standard Elbow F 45' Elbow S Straight Flow Thru Tee T 90' Flow Thru Tee V Valve LEGEND HYD REF Hydraulic reference. Refer to accompanying flow diagram. _ K FACTOR Flow factor for open head or path where Flow (gpm) = K x -\/P Qa Flow added or subtracted Qt Total flow DIA Actual internal diameter of pipe C Hazen Williams pipe roughness factor Pf/ft Friction loss per foot of pipe PIPE Length of pipe FTNG'S Number of fittings. See table above. TOTAL Total length (PIPE + FTNG'S) Pt Total pressure (psi) at fitting Pe Pressure due to change in elevation where Pe = 0.433 x change in elevation Pf Friction loss (psi) to fitting where Pf = 1 x 4.52 x (Q/C)^1.85 / ID^4.87 Pv Velocity pressure (psi) where Pv = 0.001123 x Q^2/ID^4 Pn Normal pressure (psi), where Pn = Pt - Pv NOTES: - Pressures are balanced to 0.01 psi. Pressures are listed to 0.1 psi. Addition may vary by 0.1 psi due to accumulation of round off. - Calculations conform to NFPA 13. - Velocity Pressures are not considered in these Calculations Page 3 Burton Elementary School Drawing Date:Jan 2008 1121108 11:38 Page 4 NODE ELEVATION SPRINKLER PRESSURE ACTUAL MINIMUM ACTUAL NUMBER K-FACTOR FLOW FLOW DENSITY (FT) (GPM/(PSI^'-z)) (PSI) (GPM) (GPM) (GPM/SQ.FT) 10 12.50 10.7 11 14.00 9.5 12 18.00 9.0 20 18.00 11.5 Al 24.00 60.5 A2 24.00 60.6 A3 24.00 60.7 A4 24.00 61.0 A5 24.00 61.5 A6 24.00 62.3 A7 18.00 67.9 B1 24.00 64.6 C1 12.50 26.8 C2 12.50 27.3 C3 12.50 29.1 C4 12.50 37.0 C11 12.50 44.4 C12 12.50 54.7 C13 12.50 56.6 C14 12.50 57.4 C15 12.50 57.9 C16 12.50 58.2 C17 12.50 58.4 C20 12.50 58.4 D1 12.50 34.8 El 12.50 54.8 F1 24.00 64.7 Gl 18.00 69.0 S101 12.50 5.60 10.6 18.3 16.8 0.11 5102 12.50 5.60 10.9 18.5 16.8 0.11 S103 12.50 5.60 11.7 19.2 16.8 0.11 S104 12.50 5.60 13.6 20.6 16.8 0.12 S105 14.00 5.60 9.4 17.2 16.8 0.10 5106 14.00 5.60 9.7 17.4 16.8 0.10 5107 14.00 5.60 10.4 18.1 16.8 0.11 S108 14.00 5.60 12.0 19.4 16.8 0.12 S109 18.00 5.60 9.0 16.8 16.8 0.10 5110 18.00 5.60 9.2 17.0 16.8 0.10 Sill 18.00 5.60 9.9 17.6 16.8 0.10 S112 18.00 5.60 10.9 18.5 16.8 0.11 S201 24.00 53.6 S202 24.00 54.8 5203 24.00 56.0 S204 24.00 57.2 S205 24.00 54.4 S206 24.00 55.5 S207 24.00 56.5 5208 24.00 54.8 S209 24.00 55.8 S210 24.00 56.9 W 18.00 69.1 Burton Elementary School Drawing Date:Jan 2008 1121108 11:38 Page 5 NODE ELEVATION SPRINKLER PRESSURE ACTUAL MINIMUM ACTUAL NUMBER K-FACTOR FLOW FLOW DENSITY (FT) (GPM/(PSI^',�)) (PSI) (GPM) (GPM) (GPM/SQ.FT) Max velocity of 19.38 occurs in the pipe from C3 TO D1 Burton Elementary School Drawing Date:Jan 2008 1121108 11:38 Tyco Fire Products Page 6 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG`S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn PATH 1 FROM HYDRAULIC REFERENCE S105 TO W (PRIMARY PATH) 17.21 1.380 1.77 9.4 9.4 K = 5.60 S105 C=120 0.00 0.0 0.0 17.21 0.026 1.77 0.0 9.4 Vel = 3.73 1.380 6.23 9.5 9.5 11 C=120 0.00 0.0 0.0 17.21 0.026 6.23 0.2 9.5 Vel = 3.73 17.40 1.380 8.00 9.7 9.7 K = 5.60 S106 C=120 0.00 0.0 0.0 34.61 0.094 8.00 0.8 9.7 Vel = 7.50 18.06 1.380 8.00 10.4 10.4 K = 5.60 S107 C=120 0.00 0.0 0.0 52.67 0.205 8.00 1.6 10.4 Vel = 11.41 19.44 1.380 2T 27.90 12.0 12.0 K = 5.60 S108 C=120 12.00 0.6 0.0 72.11 0.367 39.90 14.6 12.0 Vel = 15.62 76.53 2.157 11.00 27.3 27.3 C2 C=120 0.00 0.0 0.0 See PATH 2 148.64 0.159 11.00 1.7 27.3 Vel = 13.18 69.90 2.157 1T 5.17 29.1 29.1 C3 C=120 12.31 0.0 0.0 See PATH 3 218.54 0.324 17.48 5.7 29.1 Vel = 19.38 2.635 1F 14.14 34.8 34.8 D1 C=120 4.12 0.0 0.0 218.54 0.122 18.26 2.2 34.8 Vel = 12.98 -100.00 2.635 2T 154.85 37.0 37.0 C4 C=120 32.95 0.0 0.0 See PATH 5 118.54 0.039 187.80 7.4 37.0 Vel = 7.04 100.00 2.635 lE 76.28 44.4 44.4 C11 C=120 8.24 0.0 0.0 See PATH 5 218.54 0.122 84.52 10.3 44.4 Vel = 12.98 -32.58 2.635 1T 3.84 54.7 54.7 C12 C=120 16.47 0.0 0.0 See PATH 6 185.96 0.091 20.31 1.8 54.7 Vel = 11.05 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Burton Elementary School Drawing Date:Jan 2008 1121108 11:38 Tyco Fire Products Page 7 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn PATH 1 FROM HYDRAULIC REFERENCE S105 TO W (PRIMARY PATH) -30.70 2.635 12.00 56.6 56.6 C13 C=120 0.00 0.0 0.0 See PATH 7 155.26 0.065 12.00 0.8 56.6 Vel = 9.22 -29.92 2.635 12.00 57.4 57.4 C14 C=120 0.00 0.0 0.0 See PATH 8 125.34 0.044 12.00 0.5 57.4 Vel = 7.45 -29.49 2.635 12.00 57.9 57.9 C15 C=120 0.00 0.0 0.0 See PATH 9 95.85 0.027 12.00 0.3 57.9 Vel = 5.69 -29.85 2.635 12.00 58.2 58.2 C16 C=120 0.00 0.0 0.0 See PATH 10 65.99 0.013 12.00 0.2 58.2 Vel = 3.92 -30.99 2.635 12.00 58.4 58.4 C17 C=120 0.00 0.0 0.0 See PATH 11 35.00 0.004 12.00 0.0 58.4 Vel = 2.08 1.380 3E 94.90 58.4 58.4 C20 C=120 2T 21.00 -5.0 0.0 35.00 0.096 115.90 11.2 58.4 Vel = 7.58 2.635 1T 1.63 64.6 64.6 B1 C=120 16.47 0.0 0.0 35.00 0.004 18.10 0.1 64.6 Vel = 2.08 183.54 3.260 1E 6.00 64.7 64.7 F1 C=120 9.41 2.6 0.0 See PATH 6 218.54 0.043 15.41 0.7 64.7 Vel = 8.48 3.260 1T 4.90 67.9 67.9 A7 C=120 20.16 0.0 0.0 218.54 0.043 25.06 1.1 67.9 Vel = 8.48 3.260 1.39 69.0 69.0 G1 C=120 0.00 0.0 0.0 218.54 0.043 1.39 0.1 69.0 Vel = 8.48 W 218.54 69.1 K = 26.29 PATH 2 FROM HYDRAULIC REFERENCE S101 TO C2 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Burton Elementary School Drawing Date:Jan 2008 1121108 11:38 Tyco Fire Products Page 8 HYD. Qa DIA. FITTING PIPE Pt Pt - REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn PATH 2 FROM HYDRAULIC REFERENCE S101 TO C2 CONTINUED 18.27 1.380 1.77 10.6 10.6 K = 5.60 5101 C=120 0.00 0.0 0.0 18.27 0.029 1.77 0.1 10.6 Vel = 3.96 1.380 6.23 10.7 10.7 10 C=120 0.00 0.0 0.0 18.27 0.029 6.23 0.2 10.7 Vel = 3.96 18.47 1.380 8.00 10.9 10.9 K = 5.60 5102 C=120 0.00 0.0 0.0 36.74 0.105 8.00 0.8 10.9 Vel = 7.96 19.17 1.380 8.00 11.7 11.7 K = 5.60 S103 C=120 0.00 0.0 0.0 55.91 0.229 8.00 1.8 11.7 Vel = 12.11 20.62 1.380 1T 26.40 13.6 13.6 K = 5.60 5104 C=120 6.00 0.0 0.0 76.53 0.410 32.40 13.3 13.6 Vel = 16.58 2.157 11.00 26.8 26.8 Cl C=120 0.00 0.0 0.0 76.53 0.047 11.00 0.5 26.8 Vel = 6.79 C2 76.53 27.3 K = 14.64 PATH 3 FROM HYDRAULIC REFERENCE 5109 TO C3 16.80 1.380 1.77 9.0 9.0 K = 5.60 S109 C=120 0.00 0.0 0.0 16.80 0.025 1.77 0.0 9.0 Vel = 3.64 1.380 6.23 9.0 9.0 12 C=120 0.00 0.0 0.0 16.80 0.025 6.23 0.2 9.0 Vel = 3.64 16.98 1.380 8.00 9.2 9.2 K = 5.60 Silo C=120 0.00 0.0 0.0 33.78 0.090 8.00 0.7 9.2 Vel = 7.32 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Burton Elementary School Drawing Date:Jan 2008 1121108 11:38 Tyco Fire Products Page 9 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn PATH 3 FROM HYDRAULIC REFERENCE 5109 TO C3 CONTINUED 17.64 1.380 8.00 9.9 9.9 K = 5.60 Sill C=120 0.00 0.0 0.0 51.42 0.196 8.00 1.6 9.9 Vel = 11.14 18.48 1.380 2T 31.90 11.5 11.5 20 C=120 12.00 2.4 0.0 See PATH 4 69.90 0.347 43.90 15.2 11.5 Vel = 15.14 C3 69.90 29.1 K = 12.96 PATH 4 FROM HYDRAULIC REFERENCE S112 TO 20 18.48 1.049 1T 0.33 10.9 10.9 K = 5.60 S112 C=120 5.00 0.0 0.0 18.48 0.112 5.33 0.6 10.9 Vel = 6.93 20 18.48 11.5 K = 5.45 PATH 5 FROM HYDRAULIC REFERENCE C4 TO C11 100.00 2.635 6E 174.85 37.0 37.0 C4 C=120 2T 82.37 0.0 0.0 See PATH 1 100.00 0.029 257.22 7.4 37.0 Vel.= 5.94 C11 100.00 44.4 K = 15.01 PATH 6 FROM HYDRAULIC REFERENCE C12 TO F1 32.58 2.635 1T 3.06 54.7 54.7 C12 C=120 16.47 0.0 0.0 See PATH 1 32.58 0.004 19.54 0.1 54.7 Vel = 1.94 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Burton Elementary School Drawing Date:Jan 2008 1121108 11:38 Tyco Fire Products Page 10 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn PATH 6 FROM HYDRAULIC REFERENCE C12 TO F1 CONTINUED 1.380 5E 24.22 54.8 54.8 E1 C=120 1T 21.00 -5.0 0.0 32.58 0.084 45.22 3.8 54.8 Vel = 7.06 1.380 14.00 53.6 53.6 S201 C=120 0.00 0.0 0.0 32.58 0.084 14.00 1.2 53.6 Vel = 7.06 1.380 14.00 54.8 54.8 S202 C=120 0.00 0.0 0.0 32.58 0.084 14.00 1.2 54.8 Vel = 7.06 1.380 14.00 56.0 56.0 S203 C=120 0.00 0.0 0.0 32.58 0.084 14.00 1.2 56.0 Vel = 7.06 1.380 1T 33.79 57.2 57.2 S204 C=120 6.00 0.0 0.0 32.58 0.084 39.79 3.4 57.2 Vel = 7.06 2.635 12.00 60.5 60.5 Al C=120 0.00 0.0 0.0 32.58 0.004 12.00 0.0 60.5 Vel = 1.94 30.70 2.635 12.00 60.6 60.6 A2 C=120 0.00 0.0 0.0 See PATH 7 63.28 0.012 12.00 0.1 60.6 Vel = 3.76 29.92 2.635 12.00 60.7 60.7 A3 C=120 0.00 0.0 0.0 See PATH 8 93.20 0.025 12.00 0.3 60.7 Vel = 5.54 29.49 2.635 12.00 61.0 61.0 A4 C=120 0.00 0.0 0.0 See PATH 9 122.70 0.042 12.00 0.5 61.0 Vel = 7.29 29.85 2.635 12.00 61.5 61.5 A5 C=120 0.00 0.0 0.0 See PATH 10 152.55 0.063 12.00 0.8 61.5 Vel = 9.06 30.99 2.635 1T 10.37 62.3 62.3 A6 C=120 16.47 0.0 0.0 See PATH 11 183.54 0.089 26.85 2.4 62.3 Vel = 10.90 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Burton Elementary School Drawing Date:Jao 2008 1/21/88 11:38 Tyco Fire Products Page II HYD. Qa DZA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv **^+++^ NOTES POINT Qt Pf/ft TOTAL Pf Po Fl 183'54 64.7 K 22.82 PATH 7 FROM HYDRAULIC REFERENCE C13 TO A2 38.70 1.380 2E 19.12 56.6 56.6 C13 C=I20 2T 18.00 -5.0 0'0 See PATH I 30.70 0.076 37.12 2.8 56.6 VeI = 6.65 I.380 I4.00 54.4 54'4 J205 C=I20 0.00 0.0 0.0 30'70 0.076 I4.00 1.1 58.4 VeI ~ 6.65 1.380 14.00 55.5 55.5 3205 C=I20 0.00 0.0 0.0 30.70 0.076 I4.00 1.1 55.5 Vel = 6.65 1.380 IT 47.79 56.5 56.5 S207 C=120 6.00 0.0 0'0 30.78 0.076 53.79 4.1 56'5 VeI = 6.65 J\2 30.70 60.6 K = 3.94 PATH 8 FROM HYDRAULIC REFERENCE C14 TO 8k3 29.92 1.380 3E 19.12 57.4 57.4 CI4 C�120 IT 15.00 -5.0 0.0 See PATH I 29.92 0.072 34.12 2.5 57'4 VeI = 6.48 1.380 I4.00 54.8 54.8 S208 C=I20 0.00 0.0 0.0 29.92 0.072 14.00 1.0 54'8 VeI = 6.48 1.380 I4.00 55.8 55.8 S209 C=I20 0'00 0.0 0'0 29.92 0,072 14.00 1.0 55.8 VeI = 6.48 1.380 IT 47'79 55.9 56.9 S2I0 C=I20 6'00 0.0 0'0 28.92 0.072 53.79 2.9 56.9 VeI = 6.48 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Burton Elementary School Drawing Date:Jan 2008 1121108 11:38 Tyco Fire Products Page 12 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn A3 29.92 60.7 K = 3.84 PATH 9 FROM HYDRAULIC REFERENCE C15 TO A4 29.49 1.380 3E 94.90 57.9 57.9 C15 C=120 2T 21.00 -5.0 0.0 See PATH 1 29.49 0.070 115.90 8.1 57.9 Vel = 6.39 A4 29.49 61.0 K = 3.78 PATH 10 FROM HYDRAULIC REFERENCE C16 TO A5 29.85 1.380 3E 94.90 58.2 58.2 C16 C=120 2T 21.00 -5.0 0.0 See PATH 1 29.85 0.072 115.90 8.3 58.2 Vel = 6.47 A5 29.85 61.5 K = 3.81 PATH 11 FROM HYDRAULIC REFERENCE C17 TO A6 30.99 1.380 3E 94.90 58.4 58.4 C17 C=120 2T 21.00 -5.0 0.0 See PATH 1 30.99 0.077 115.90 8.9 58.4 vel = 6.71 A6 30.99 62.3 K = 3.93 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) — CO) N P CA Cb O O O O O N O M c7 O O 81, CD O O W O O O W Cn o c- 3 .A 0 0 .A cn 0 Cr 0 O Q O 3 ZY O Cn CD L CD W CW O 3 .-. Q- O Q. CD Ill DC/)Cna @ o 0 3 sv�oo zy O X cn CS O• S fn O O_ nxccn 0 (D SU CD o v — CD o �(n CD j O C CO CD C N O .. O 00 O W O �OOCT O O O �-0 (n Cn cn 3 90 N N CD — N C �� cD a m � cn .. cn co cn in Co CO . -0 _3 _. O� 2 c CA 0 a(n m�D O o � oo� (0(0 0 v CD 3 3 0100. SHILO AUTOMATIC SPRINKLERS, Inc. 9 QUALITY FIRE PROTECTION 1224 ELEVENTH AVE NORTH NAMPA, IDAHO 83687 HYDRAULIC CALCULATIONS CALC AREA 2 Lillie Scales Fire Protection Design Email: design@shilosprinkler.com Phone (208) 442-0007 • (208) 466-0006 • Fax (208) 466-7890 • E-MAIL design@shilosprinkler.com Burton Elementary School Drawing Date:Jan 2008 HYDRAULIC DESIGN INFORMATION SHEET Job Name: Burton Elementary School Location: Madison School District West 7th South, Rexburg ID Drawing Date: Jan 2008 Contractor: SHILO Automatic Sprinkler 1224 Eleventh Avenue North Nampa, Idaho 83687 Designer: Design Dept Calculated By:SprinkCAD www.sprinkcad.com 451 N. Cannon Ave. Lansdale, PA 19446 Construction: Combustible Reviewing Authorities:Rexburg Fire District, SYSTEM DESIGN 1121108 11:40 Remote Area Number: 2 Telephone:208-466-0006 Occupancy:School Owner Code:NFPA 13 Hazard:Light System Type:WET Area of Sprinkler Oper. 1590 sq ft1 Sprinkler or Nozzle Density (gpm/sq ft) 0.100 1 Make: TYCO Area per Sprinkler 168.0 sq ft1 Model: TY-FRB Hose Allowance Inside 0 gpm I K-Factor: 5.60 Hose Allowance Outside 100 gpm J Temperature Rating: 155 CALCULATION'SUMMARY 10 Flowing Outlets gpm Required: 276.8 psi Required: 40.3 @ Source WATER SUPPLY Water Flow Test I Pump Data Date of Test 01/17/2008 1 Rated Capacity 0 gpm I Static Pressure 95.0 psi I Rated Pressure 0.0 psi Residual Pres 30.0 psi I Elevation 0 I At a Flow of 4000 gpm I Make: Elevation 0" I Model: I Location: W 7th S & S 12th W, Rexburg Source of Information: Contractor Flow Test SYSTEM VOLUME 646 Gallons Notes: GRID PEAKED CURRENT LOCATION REQUIRED 40.284 psi 276.85 gpm SHIFT RIGHT(UP) REQUIRED 39.501 psi 275.90 gpm Burton Elementary School Drawing Date:Jan 2008 1121108 11:40 HYDRAULIC CALCULATION DETAILS HYDRAULIC FLOW LOSS QTY DESCRIPTION LENGTH C ID gpm psi TOTALS Hydr Ref W Required at Hyd Area 2 177 21.7 psi Elevation Change 17'0" 7.4 1 3" Grvd 90 Ell 7' 120 3.068 177 0.3 1 Pipe 3" 40x2l 13' 120 3.068 177 0.5 1 3" Grvd Other Valve Tyco 513 CHART LOSS 177 3.0 1 3" Grvd Butterfly Valve "BFV" 10' 120 3.068 177 0.4 1 3" Grvd Back Flow Valve Ames "200" CHART LOSS 177 3.2 1 3" Grvd Tee 15' 120 3.068 177 0.7 1 Pipe 3" 10x21 1' 120 3.260 177 0.0 Hydr Ref BOR Required at Base of Riser 177 37.2 psi Elevation Change 6'0" 2.6 1 Pipe 6" DIx18 Cl 350 6' 140 6.338 177 0.0 1 6" MJ 90 Ell 14' 120 6.065 177 0.0 1 Pipe 6" C-900x21 350' 150 6.300 177 0.3 2 6" MJ 45 Ell 14' 120 6.065 177 0.0 1 6" MJ Tee 30' 120 6.065 177 0.0 Hydr Ref Ml Required at City Main 177 40.1 psi Fixed Flow Outside Hose Allow. 100 gpm 1 Pipe 12" DIx18 Cl 350 2000' 140 12.578 277 0.1 1 12" MJ Tee 60' 120 11.938 277 0.0 Hydr Ref SRC Required at Source 277 40.3 psi Water Source 95.0 psi static, 30.0 psi residual @ 4000 gpm 277 gpm 94.5 psi SAFETY PRESSURE 54.3 psi Available Pressure of 94.5 psi Exceeds Required Pressure of 40.3 psi This is a safety margin of 54.3 psi or 57 % of Supply Maximum Water Velocity is 9.1 fps Burton Elementary School Drawing Date:Jan 2008 1121108 11:40 FITTING NAME TABLE ABBREV. NAME C Coupling E 90' Standard Elbow F 45' Elbow S Straight Flow Thru Tee T 90' Flow Thru Tee V Valve LEGEND HYD REF Hydraulic reference. Refer to accompanying flow diagram. _ K FACTOR Flow factor for open head or path where Flow (gpm) = K x -\/P Qa Flow added or subtracted Qt Total flow DIA Actual internal diameter of pipe C Hazen Williams pipe roughness factor Pf/ft Friction loss per foot of pipe PIPE Length of pipe FTNG'S Number of fittings. See table above. TOTAL Total length (PIPE + FTNG'S) Pt Total pressure (psi) at fitting Pe Pressure due to change in elevation where Pe = 0.433 x change in elevation Pf Friction loss (psi) to fitting where Pf = 1 x 4.52 x (Q/C)^1.85 / ID^4.87 Pv Velocity pressure (psi) where Pv = 0.001123 x Q^2/ID^4 Pn Normal pressure (psi), where Pn = Pt - Pv NOTES: - Pressures are balanced to 0.01 psi. Pressures are listed to 0.1 psi. Addition may vary by 0.1 psi due to accumulation of round off. - Calculations conform to NFPA 13. - Velocity Pressures are not considered in these Calculations Page 3 Burton Elementary School Drawing Date:Jan 2008 1121108 11:40 Page 4 NODE ELEVATION SPRINKLER PRESSURE ACTUAL MINIMUM ACTUAL NUMBER K-FACTOR FLOW FLOW DENSITY (FT) (GPM/(PSI^'-�)) (PSI) (GPM) (GPM) (GPM/SQ.FT) Al 24.00 14.5 A2 24.00 14.6 A3 24.00 14.8 A4 24.00 15.1 A5 24.00 15.6 A6 24.00 16.2 A7 18.00 20.9 B1 24.00 17.9 C4 12.50 17.1 C11 12.50 17.1 C12 12.50 17.1 C13 12.50 17.1 C14 12.50 17.2 C15 12.50 17.4 C16 12.50 17.5 C17 12.50 17.6 C20 12.50 17.6 E1 12.50 17.1 Fl 24.00 17.9 G1 18.00 21.7 S201 24.00 5.60 9.2 17.0 16.8 0.10 S202 24.00 5.60 9.0 16.8 16.8 0.10 5203 24.00 5.60 9.0 16.8 16.8 0.10 S204 24.00 5.60 9.6 17.4 16.8 0.10 S205 24.00 5.60 10.4 18.0 16.8 0.11 5206 24.00 5.60 10.3 18.0 16.8 0.11 5207 24.00 5.60 10.5 18.2 16.8 0.11 S208 24.00 5.60 10.6 18.2 16.8 0.11 5209 24.00 5.60 10.5 18.2 16.8 0.11 5210 24.00 5.60 10.7 18.3 16.8 0.11 W 18.00 21.7 Max velocity of 9.13 occurs in the pipe from A6 TO Fl Burton Elementary School Drawing Date:Jan 2008 1121108 11:40 Tyco Fire Products Page 5 �. _ _ ....gym ......., . HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn PATH 1 FROM HYDRAULIC REFERENCE S202 TO W (PRIMARY PATH) 11.18 1.380 14.00 9.0 9.0 K = 3.73 S202 C=120 0.00 0.0 0.0 11.18 0.012 14.00 0.2 9.0 Vel = 2.42 16.95 1.380 5E 24.22 9.2 9.2 K = 5.60 S201 C=120 1T 21.00 5.0 0.0 28.13 0.064 45.22 2.9 9.2 Vel = 6.09 2.635 3.06 17.1 17.1 El C=120 0.00 0.0 0.0 28.13 0.003 3.06 0.0 17.1 Vel = 1.67 2.635 3.84 17.1 17.1 C12 C=120 0.00 0.0 0.0 28.13 0.003 3.84 0.0 17.1 Vel = 1.67 23.57 2.635 12.00 17.1 17.1 C13 C=120 0.00 0.0 0.0 See PATH 4 51.70 0.009 12.00 0.1 17.1 Vel = 3.07 24.02 2.635 12.00 17.2 17.2 C14 C=120 0.00 0.0 0.0 See PATH 6 75.72 0.017 12.00 0.2 17.2 Vel = 4.50 -16.28 2.635 12.00 17.4 17.4 C15 C=120 0.00 0.0 0.0 See PATH 7 59.44 0.011 12.00 0.1 17.4 Vel = 3.53 -17.33 2.635 12.00 17.5 17.5 C16 C=120 0.00 0.0 0.0 See PATH 8 42.11 0.006 12.00 0.1 17.5 Vel = 2.50 -18.90 2.635 12.00 17.6 17.6 C17 C=120 0.00 0.0 0.0 See PATH 9 23.21 0.002 12.00 0.0 17.6 Vel = 1.38 1.380 3E 94.90 17.6 17.6 C20 C=120 2T 21.00 -5.0 0.0 23.21 0.045 115.90 5.2 17.6 Vel = 5.03 2.635 1T 1.63 17.9 17.9 B1 C=120 16.47 0.0 0.0 23.21 0.002 18.10 0.0 17.9 Vel = 1.38 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Burton Elementary School Drawing Date:Jan 2008 1121108 11:40 Tyco Fire Products Page 6 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn PATH 1 FROM HYDRAULIC REFERENCE S202 TO W (PRIMARY PATH) 153.63 3.260 1E 6.00 17.9 17.9 F1 C=120 9.41 2.6 0.0 See PATH 2 176.85 0.029 15.41 0.5 17.9 Vel = 6.86 3.260 1T 4.90 20.9 20.9 A7 C=120 20.16 0.0 0.0 176.85 0.029 25.06 0.7 20.9 Vel = 6.86 3.260 1.39 21.7 21.7 G1 C=120 0.00 0.0 0.0 176.85 0.029 1.39 0.0 21.7 Vel = 6.86 W 176.85 21.7 K = 37.95 PATH 2 FROM HYDRAULIC REFERENCE S202 TO F1 5.62 1.380 14.00 9.0 9.0 K = 1.87 5202 C=120 0.00 0.0 0.0 5.62 0.003 14.00 0.0 9.0 Vel = 1.22 16.84 1.380 14.00 9.0 9.0 K = 5.60 5203 C=120 0.00 0.0 0.0 22.46 0.042 14.00 0.6 9.0 Vel = 4.86 17.39 1.380 1T 33.79 9.6 9.6 K = 5.60 5204 C=120 6.00 0.0 0.0 39.85 0.123 39.79 4.9 9.6 Vel = 8.63 2.635 12.00 14.5 14.5 Al C=120 0.00 0.0 0.0 39.85 0.005 12.00 0.1 14.5 Vel = 2.37 30.63 2.635 12.00 14.6 14.6 A2 C=120 0.00 0.0 0.0 See PATH 3 70.48 0.015 12.00 0.2 14.6 Vel = 4.19 30.65 2.635 12.00 14.8 14.8 A3 C=120 0.00 0.0 0.0 See PATH 5 101.13 0.029 12.00 0.4 14.8 Vel = 6.01 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Burton Elementary School Drawing Date:Jan 2008 1121108 11:40 Tyco Fire Products Page 7 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn PATH 2 FROM HYDRAULIC REFERENCE S202 TO F1 CONTINUED 16.28 2.635 12.00 15.1 15.1 A4 C=120 0.00 0.0 0.0 See PATH 7 117.40 0.039 12.00 0.5 15.1 Vel = 6.97 17.33 2.635 12.00 15.6 15.6 A5 C=120 0.00 0.0 0.0 See PATH 8 134.73 0.050 12.00 0.6 15.6 Vel = 8.00 18.90 2.635 1T 10.37 16.2 16.2 A6 C=120 16.47 0.0 0.0 See PATH 9 153.63 0.064 26.85 1.7 16.2 Vel = 9.13 F1 153.63 17.9 K = 36.33 PATH 3 FROM HYDRAULIC REFERENCE S206 TO A2 12.46 1.380 14.00 10.3 10.3 K = 3.88 S206 C=120 0.00 0.0 0.0 12.46 0.014 14.00 0.2 10.3 Vel = 2.70 18.17 1.380 1T 47.79 10.5 10.5 K = 5.60 S207 C=120 6.00 0.0 0.0 30.63 0.075 53.79 4.1 10.5 Vel = 6.63 A2 30.63 14.6 K = 8.02 PATH 4 FROM HYDRAULIC REFERENCE S206 TO C13 5.53 1.380 14.00 10.3 10.3 K = 1.72 S206 C=120 0.00 0.0 0.0 5.53 0.003 14.00 0.0 10.3 Vel = 1.20 18.03 1.380 2E 19.12 10.4 10.4 K = 5.60 S205 C=120 2T 18.00 5.0 0.0 23.57 0.046 37.12 1.7 10.4 Vel = 5.10 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Burton Elementary School Drawing Date:Jan 2008 1121108 11:40 Tyco Fire Products Page 8 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn C13 23.57 17.1 K = 5.70 PATH 5 FROM HYDRAULIC REFERENCE S209 TO A3 12.33 1.380 14.00 10.5 10.5 K = 3.80 S209 C=120 0.00 0.0 0.0 12.33 0.014 14.00 0.2 10.5 Vel = 2.67 18.32 1.380 1T 47.79 10.7 10.7 K = 5.60 S210 C=120 6.00 0.0 0.0 30.65 0.075 53.79 4.1 10.7 Vel = 6.64 A3 30.65 14.8 K = 7.98 PATH 6 FROM HYDRAULIC REFERENCE S209 TO C14 5.82 1.380 14.00 10.5 10.5 K = 1.80 S209 C=120 0.00 0.0 0.0 5.82 0.003 14.00 0.0 10.5 Vel = 1.26 18.19 1.380 3E 19.12 10.6 10.6 K = 5.60 S208 C=120 1T 15.00 5.0 0.0 24.02 0.048 34.12 1.6 10.6 Vel = 5.20 C14 24.02 17.2 K = 5.79 PATH 7 FROM HYDRAULIC REFERENCE C15 TO A4 16.28 1.380 3E 94.90 17.4 17.4 C15 C=120 2T 21.00 -5.0 0.0 See PATH 1 16.28 0.023 115.90 2.7 17.4 Vel = 3.53 A4 16.28 15.1 K = 4.19 PATH 8 FROM HYDRAULIC REFERENCE C16 TO A5 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Burton Elementary School Drawing Date:Jan 2008 1121108 11:40 Tyco Fire Products Page 9 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn PATH 8 FROM HYDRAULIC REFERENCE C16 TO A5 CONTINUED 17.33 1.380 3E 94.90 17.5 17.5 C16 C=120 2T 21.00 -5.0 0.0 See PATH 1 17.33 0.026 115.90 3.0 17.5 Vel = 3.75 A5 17.33 15.6 K = 4.39 PATH 9 FROM HYDRAULIC REFERENCE C17 TO A6 18.90 1.380 3E 94.90 17.6 17.6 C17 C=120 2T 21.00 -5.0 0.0 See PATH 1 18.90 0.031 115.90 3.6 17.6 Vel = 4.09 A6 18.90 16.2 K = 4.70 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) N A O Cb O O O O 1 O N P O [7 n a 0 0 CJi O N O O Iv Ul O W O O O O O 0 (fl 3 zy 0 V1 CD -u:* j�: C- CD M W 0 3cr 0 CD V o g� m D C/) C/) CD o 0 0 N O - — N (D M iS � • 0 O O_ o=n�upg w CD cu i -� r• r 2 0 0 CD O O Cn cn (D W C v in N C N O .. O W .A. W (D CD O Cr O O O (o 'O 'O S -0 U) N cn 3 90 co-i-0;a _ - CD lD N (n (n — C -u O CD m (n C � N � A V O W V W N � N c (n O in CD (D CD CD _> _ O o 00� 0o O 3 3 —4cnv �nPrJ u+ CD D.� 'o m c cn 0 0 SHILO AUTOMATIC SPRINKLERS, Inc. #I QUALITY FIRE PROTECTION 1224 ELEVENTH AVE NORTH NAMPA, IDAHO 83687 WATER FLOW INFORMATION Lillie Scales Fire Protection Design Email: design@shilosprinkler.com Phone (208) 442-0007 • (208) 466-0006 • Fax (208) 466-7890 • E-MAIL design@shilosprinkler.com m ■m Em 0 1e }'' SHILO AUTOMATIC SPRINKLERS, inc. y QUALITY FIRE PROTECTION 1224 ELEVENTH AVE NORTH NAWA, IDAHO 83687 SEISMIC BRACING CALCULATIONS Lillie Scales Fire Protection Design Email: design@shilosprinkler.com Phone (208) 442-0007 • (208) 466-0006 • Fax (208) 466-7890 • E-MAIL design@shilosprinkler.com Prepared by Clarence Calkins, CET (NICET # 104776) (12/19/2007) Page 1 SHILO AUTOMATIC SPRINKLERS, Inc. i QUALITY FIRE PROTECTION 1224 ELEVENTH AVE N012TH NAMPA, IllAHO 83687 SEISMIC BRACING CALCULATIONS JOB NAME: ARCHER-LYMAN E.S. RISER JOB #: 10 07001 Seismic Brace ti Brace Type Pipe Size I Pipe Type Pipe Length WEIGHT (Lbs/Ft) See NFPA 13 TableA.9.3.5.6 G' Factor Tot. Wgt. Brace Tot. Wgt. Brac4 Size Notes / Comments FASTE14ER 2-- A A 4-Way 8 SCH10 40.08 0.5 0.00 6 SCH10 23.03 0.5 0.00 4 SCH10 11.78 0.5 0.00erwrE 3 SCH10 7.94 0.5 0.00 21/2 SCH10 5.89 0.5 1 0.00 2 ISCH10 4.22 0.5 1 0.00 1 1/2 SCH10 3.04 0.5 1 0.00 3 SCH40 10 10.82 0.5 19.00 2 SCH40 5.13 0.5 0.00 Length of Brace TO" 1 1/2 SCH40 3.61 0.5 0.00 1 1/4 SCH40 2.93 0.5 0.00 Minimum 1/2" Fasteners 1 SCH40 2.05 0.5 0.00 Total Wei ht 19.00 1" Fi ure s Fp x 1.15 21.85 1" ALL FIGURES w f F�srrrM ` B LAT 8 SCH10 40.08 0.5 1 0.00 6 SCH10 23.03 0.5 0.00 4 SCH10 11.78 0.5 0.00 3 ISCH10 7.94 0.5 0.00_'` 21/2 SCH10 40 1 5.89 0.5 1 117.80 2 SCH10 1 4.22 0.5 0.00 1 1/2 SCH10 3.04 0.5 0.00 3 SCH40 10.82 0.5 0.00 2 SCH40 5.13 0.5 0.00 Length of Brace TO" 1 1/2 1 SCH40 300 3.61 0.5 541.50 1 1/4 SCH40 70 2.93 0.5 102.55 Minimum 1/2" Fasteners 1 SCH40 70 1 2.05 0.5 71.75 Total Weight 761.85 1" Figure s Fp x 1.15 876.13 1" all figures C LONG 8 SCH10 1 40.08 0.5 0.00 6 SCH10 1 23.03 0.5 0.00 fF� a 4 SCH10 11.78 0.5 0.00 3 SCH10 7.94 0.5 0.00 21/2 SCH10 80 5.89 0.5 235.60 2 SCH10 4.22 0.5 1 0.00 1 1/2 1 SCH10 3.04 0.5 1 0.00 3 SCH40 10.82 0.5 1 0.00 2 SCH40 5.13 0.5 0.00 Length of Brace 7'0" 1 1/2 SCH40 300 3.61 0.5 541.50 1 1/4 SCH40 70 2.93 0.5 102.55 Minimum 1/2" Fasteners 1 SCH40 70 2.05 0.5 71.75 Total Wei ht 879.65 1" Figure s Fp x 1.15 1011.60 1" ABCDEFGHI Unless noted otherwise, sway bracing to be 1" schedule 40 pipe with a slenderness ratio of 200 (Using 1/2" fasteners). EQUAKEALS SNILO AUTOMATIC SPRINKLERS Inc. Ix` QUALITY FIRE PROTECTION 1224 ELEVENTH AVE NORTH NAMPA, IDAHO 83687 -• w PRODUCT DATA Lillie Scales Fire Protection Design Email: design@shilosprinkler.com Phone (208) 442-0007 • (208) 466-0006 0 Fax (208) 466-7890 • E-MAIL design@shilosprinkler.com tqC0 Fire &Building Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Model BFV-N Butterfly Valve Grooved End 21/z Inch - 10 Inch (DN65 - DN250) General Description The Model BFV-N Grooved End But- terfly Valves (Ref. Figure 1) are indicat- ing type valves designed for use in fire protection systems where a visual in- dication is required as to whether the valve is open or closed. They are used, for example, as system, sectional, and pump water control valves. They have cut groove inlet and outlet connections that are suitable for use with grooved end pipe couplings that are listed and approved for fire protection systems. For applications requiring supervision of the open position of the valve, the Gear Operators for the Model BFV-N Butterfly Valves are provided with two sets of factory installed internal switches each having SPDT contacts. The supervisory switches transfer their electrical contacts when there is move- ment from the valve's normal open po- sition during the first two revolutions of the handwheel. WARNINGS The Model BFV-N Grooved End But- terfly Valves described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authori- ties having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Technical Data Model BFV-N Sizes: ANSI Inches / DN 21/2 (DN65), 3 (DN80), 4 (DN100), 5 (DN125), 6 (DN150), 8 (DN200), 10 (DN250) Approvals The 21/2through 10 inch (DN65 - DN250) Model BFV-N Grooved End Butterfly Valves are UL and C-UL Listed and FM Approved. All laboratory listings and approvals are for indoor and outdoor use. Maximum Working Pressure • 21/2 - 8 Inch (DN65 - DN200): 300 psi (20,7) bar • 10 Inch (DN250): 175 psi (12,0 bar) Materials of Construction: Body Ductile iron conforming to ASTM A-395 Body Coating Polyamide Disc Ductile iron conforming to ASTM A-395 Disc Seal Grade EPDM "E" encapsulated rubber conforming to ASTM D-2000 Upper & Lower Stem Type 416 Stainless Steel conforming to ASTM 582 Lower Plug PVC Operator Gear operator with iron housing Friction Loss The approximate friction loss, based on the Hazen Williams formula and ex- pressed in equivalent length of pipe with C= 120, is as follows. The data is based on friction loss information col- lected at a typical flow rate of 15 feet persecond. • 6.9 feet of 21/2 inch Sch. 40 pipe for the 21/2 inch valve. • 8.7 feet of 3 inch Sch. 40 pipe for the 3 inch valve. • 4.5 feet of 4 inch Sch. 40 pipe for the 4 inch valve. • 6.6 feet of 5 inch Sch. 40 pipe for the 5 inch valve. • 11.1 feet of 6 inch Sch. 40 pipe for the 6 inch valve. • 10.2 feet of 8 inch Sch. 30 pipe for the 8 inch valve. • 12.1 feet of 10 inch Sch. 30 pipe for the 10 inch valve. Page i of 4 MARCH, 2006 TFP1510 Page 2 of 4 TFP1510 Nominal Valve pipe Nominal Installation Dimensions in Inches and (mm) Weight Sizes O.D. A B C D E F G H lbs. (kg) 2-1/2" 2.88 3.85 11.71 3.25 5.43 6.00 7.81 2.50 22 DN65 (73,0) (98,0) (297,4) (83,0) (137,9) (152,4) (198,4) (63,5) 0 (10,0) 3" 3.50 3.85 12.25 3.54 5.68 6.00 7.81 2.50 23 DNBO (66,9) (98,0) (311,1) (9010) (144,2) (152,4) (198,4) (63,5) 0 (10,4) 4" 4.50 4.56 13.95 4.35 6.58 6.00 7.81 2.50 28 DN100 (114,3) (116,0) (354,3) (110,0) (167,1) (152,4) (198,4) (63,5) D (12,7) 5" 5.56 5.66 14.93 4.84 7.07 6.00 7.81 2.50 31 DN125 (141,3) (149,0) (379,2) (123,0) (179,6) (152,4) (198,4) (63,5) D (14,1) 6" 6.63 5.86 17.31 5.93 8.35 6.00 7.81 2.50 0.67 41 DN150 (168,3) (149,0) (439,7) (151,0) (212,0) (152,4) (196,4) (63,5) (17,0) (18,6) 8" 8.63 5.26 19.20 6.87 9.29 6.00 7.81 2.50 5.86 53 DN200 (219,1) (134,0) (487,7) (174,0) (236,0) (152,4) (198,4) (63,5) (148,8) (24,1) 10" 10.75 6.29 25.11 9.17 11.50 9.00 7.68 3.00 7.41 88 DN250 (273,1) (160,0) (637,8) (233,0) (292,1) (228,6) (195,1) (40,0) G F HANDWHEEL INDICATOR FLAG 1/2" NPT tH ONDUIT NECTION GEAR OPERATOR E BODY D B C A FIGURE 1 MODEL BFV-N GROOVED END BUTTERFLY VALVE - NOMINAL DIMENSIONS - TFP1510 Installation The Model BFV-N Grooved End But- terfly Valves may be installed with flow in either direction and can be posi- tioned either horizontally or vertically. The grooved end pipe couplings used with the Model BFV-N must be listed or approved for fire protection service and installed in accordance with the manufacturers instructions. The Model BFV-N Butterfly Valve may be installed with any schedule of pres- sure class of pipe or tubing that is list- ed or approved for fire protection. As applicable, refer to Figure 2 for the internal switch wiring diagram. Conduit and electrical connections are to be made in accordance with the authority having jurisdiction and/ or the National Electrical Code. With reference to Figure 2, the "supervi- sory switch" is intended for connec- tion to the supervisory circuit of a fire alarm control panel in accordance with NFPA 72. The "auxiliary switch" is in- tended for the unsupervised connec- tion to auxiliary equipment in accor- dance with NFPA 70, National Electric Code. NOTE For outdoor applications with inter- nal supervisory switches, it is recom- mended that wiring connections be made at a temperature above 15°F (-9°C), in order to insure sufficient flex- ibility of the wire lead insulation. Care and Maintenance The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and devic- es in accordance with the applicable standards of the National Fire Pro- tection Association (e.g., NFPA25), in addition to the standards of any au- thority having jurisdiction. The install- ing contractor or product manufac- turer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, test- ed, and maintained by a qualified in- spection service. -- SUPERVISORY SWITCH SWITCH SHOWN L — — J WITH VALVE FULL OPEN 0 0 0 0 J J Q Q > } 0 0 END OF LINE RESISTOR PANEL �-- AUXILIARY GND I SWITCH SWITCH SHOWN L — — J WITH VALVE FULL OPEN w a cc:O ¢ M C 0 ' z CONTACT RATING .... 1/2A ® 125 VDC 1MA ® 250 VDC 15.1A/12HP ® 125, 250 VAC 5A ® 125 VAC "L" FIGURE 2 MODEL BFV-N BUTTERFLY VALVE — INTERNAL SWITCH WIRING DIAGRAM — NOTE Before closing a fire protection system control valve for maintenance or in- spection work on either the valve or fire protection system which it controls, permission to shut down the affected fire protection systems must be ob- tained from the proper authorities and all personnel who may be affected by this decision must be notified. Page 3 of 4 Page 4 of 4 TFP1510 Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warran- ty is given for products or components manufactured by companies not af- filiated by ownership with TFBP or for products and components which have been subject to misuse, improper in- stallation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protec- tion Association, and/or the standards of any other Authorities Having Juris- diction. Materials found by TFBP to be defective shall be either repaired or re- placed, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other ob- ligation in connection with the sale of products or parts of products. TFBP shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties. ex- press or implied including warranties of merchantability and fitness for a par- ticular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full extent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure Grooved End Butterfly Valves: Specify: (specify inch size) Model BFV-N Grooved End Butterfly Valve with internal supervisory switches, P/N (specify) Valve Size Valve Part Number 2%*.... . .................. 59-300-F-025N 3..........................59-300-F-030N 4..........................59-300-F-040N 5..... ..................... 59-300-F-050N 6..........................59-300-F-060N 8.......... ................ 59-300-F-080N 10......................... 59-300-F-010N TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale Pennsylvania 19446 tLICO Fire & Building Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Model 513 (13) Riser Manifold 1-1 /2 thru 61nch (DN40 thru DN 150) For NFPA 13 Sprinkler Systems General Description The Figure 513 (13) Riser Manifolds described in this technical data sheet provide the necessary waterflow alarm, pressure gauge, alarm test ori- fice, drain, and sight glass equipment in a single assembly for use in NFPA 13 sprinkler systems as follows: NFPA 13* • 1-1/2 Inch (DN40) Male Thread x Female Thread • 1-1/2 thru 6 Inch (DN40 thru DN150) Groove x Groove *Although the Riser Manifold described in this data sheet is intended for NFPA 13 sprinkler systems, it may be used for NFPA 13D or 13R residential sprinkler systems, where a test orifice of 5.6K (80K) is accept- able. The variety of sizes and grooved end connections allow cost effective and easy transition to check valves, control valves, and system piping. The Riser Manifolds may be installed in either the horizontal (flow switch on top) or verti- cal (flow going up) for both single sprinkler rises and floor control in high rises. WARNING The Riser Manifolds described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation, in addition to the standards of any other authorities having jurisdic- tion. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Technical Data Approvals The Figure 513 (13) Riser Manifolds with a cover tamper switch for the wa- terflow alarm switch are UL Listed, ULC Listed, and FM Approved. The Figure 513 (13) Riser Manifolds without a cover tamper switch for the waterflow alarm switch are UL Listed and FM Approved. Maximum Working Pressure 175 psi (12,1 bar) Test Orifice 5.6K (80K) Assembly The manifold body of the Figure 513 is ductile iron, whereas the manifold body of the Figure 13 is cast iron. The two assemblies are completely inter- changeable in function, application, and end -to -end laying length. Finish Red painted. Installation The Riser Manifolds may be installed in either the horizontal (flow switch on top) or vertical (flow going up). The inlet of the Riser Manifold may be di- rectly connected to a shut-off control valve. NOTES Where applicable pipe thread sealant is to be applied sparingly. Use of a non -hardening pipe thread sealant is recommended. Never remove any piping component nor correct or modify any piping defi- ciencies without first depressurizing and draining the system. Step 1. Install the manifold body with the flow arrow pointing in the down- stream position using threaded con- nections and/or listed mechanical grooved connections, as applicable Step 2. Connect the drain line, and then close the drain valve. Step 3. Refer to Figure 3 for wiring guidance. All wiring must be per- formed in accordance with the Author- ity Having Jurisdiction and/or the Na- tional Electrical Code. Step 4. Refer to Figure 4 for optional relief valve. Step 5. Place the system in service by filling the system with water. When fill- ing the system, partially open the con- trol valve to slowly fill the system. Fill- ing the system slowly will help avoid damaging the waterflow alarm switch. After the system is fully pressurized, completely open the control valve. Step 6. Secure all supply valves open. Pagel of 6 APRIL, 2006 TFP962 Page 2 of 6 TFP962 NO. DESCRIPTION QTY. P/N 1 1-1/2" Manifold Body, Male x Female NPT..... 1 N/A Groove x Groove ....... 1 N/A 2 Waterflow Alarm Switch: VSR-SF with Paddle, UL/FM ............... 1 971-096-00 VSR-SF with Paddle and Cover Tamper Switch, ULC/FM .............. 1 976-519-02 3 300 psi/2000 kPa Water Pressure Gauge .. 1 2341 1 10" (254,0 mm) 14-1/4" Male x Female NPT, (362,0 mm) Groove x Groove Manifolds 11-1/8" (282,6 mm) Inspector's Test ) Male x Male NPT & Drain Valve Drain Valve Manifolds (Normally set O(Normally to "Drain") Closed) O 1 i NOTES: 1. Approximate weight, 11.2 lbs. (5,1 kg). 2. ULC Listed Manifolds are equipped with Cover Tamper Switches installed internal to the Waterfiow Alarm Switches. 3. CH: Common Hardware 3 V i �Ip2 5-3/16" 3-1/2" 3/4" 1" L (131,8 mm) (19,1 mm) NPT (88,9mm) 6-118" (155,6 mm) 12-5/8" (320,7 mm) FIGURE 1 1-112INCH (DN40) RISER MANIFOLD ASSEMBLYAND DIMENSIONS TFP962 21NCH (DN50) MANIFOLD NO. DESCRIPTION CITY. P/N 1 2" Manifold Body, Groove x Groove ....... 1 N/A 2 Waterflow Alarm Switch: VSC with Paddle, UL/FM ............... 1 976-357-01 VSC with Paddle and Cover Tamper Switch, ULC/FM .............. 1 976-520-01 3 300 psi/2000 kPa Water Pressure Gauge .. 1 2341 2-1/2 INCH (DN65) MANIFOLD NO. DESCRIPTION QTY. PIN 1 2-1/2" Manifold Body, Groove x Groove ....... 1 N/A 2 Waterflow Alarm Switch: VSC with Paddle, UL/FM ............... 1 976-357-02 VSC with Paddle and Cover Tamper Switch, ULC/FM .............. 1 976-520-02 3 300 psi/2000 kPa Water Pressure Gauge .. 1 2341 3INCH (DN80) MANIFOLD NO. DESCRIPTION QTY. P/N 1 3" Manifold Body, Groove x Groove ....... 1 N/A 2 WalerflowAlarm Switch: VSC with Paddle, UL/FM ............... 1 976-357-03 VSC with Paddle and Cover Tamper Switch, ULC/FM .............. 1 976-520-03 3 300 psi/2000 kPa Water Pressure Gauge .. 1 2341 NOTES: 1. ULC Listed Manifolds are equipped with Cover Tamper Switches installed internal to the Waterflow, Alarm Switches. 2. CH: Common Hardware 4INCH (DN100) MANIFOLD NO. DESCRIPTION QTY. PIN 1 4" Manifold Body, Groove x Groove ....... 1 N/A 2 Waterflow Alarm Switch: VSC with Paddle, UL/FM ............... 1 976-357-04 VSC with Paddle and Cover Tamper Switch, ULC/FM .............. 1 976-520-04 3 300 psi/2000 kPa Water Pressure Gauge .. 1 2341 Page 3 of 6 61NCH (DN150) MANIFOLD NO. DESCRIPTION QTY. PIN 1 6" Manifold Body, Groove x Groove ....... 1 N/A 2 Waterflow Alarm Switch: VSC with Paddle, UL/FM ............... 1 976-357-05 VSC with Paddle and Cover Tamper Switch, ULC/FM .............. 1 976-520-05 3 300 psi/2000 kPa Water Pressure Gauge .. 1 2341 Manifold Nominal Installation Dimensions in Inches and mm Drain Size Weight Size A B C D E I F G H Ibs.(kg) 21nch 13 9/16 5-3/8 6-3/8 13-1/16 3-1/2 13.5 (DN50) (330,2) (14,3) (136,5) (161,9) (331,6 (88,9) 1" NPT (6,1) 2-1/2 Inch 13 1 5-3/4 6-7/8 13-3/4 3-1/2 16.8 DN65 V20-1/2 330,2 25,4 146,1 174,6 349,3 88,9 1-1/4" NPT 7,6 3 Inch 13 1 6 7-1/8 14-1/4 3-1/2 18.7 DN80 330,2 25,4 152,4 181,0 362,0 88,9 1-1/4" NPT 8,5 4 Inch 13 4-5116 7-9/16 9-1/16 16-5/8 4-1/2 32.7 DN100 520,7 330,2 109,5 192,1 230,2 422,3 114,3 2" NPT 14,8 6 Inch 20-1/2 13 4-5/16 8-1/2 10 18-1/2 6-5/8 41.6 DN 150 (520,7) (330,2) (109,5) (215,9) (254,0) 469 9 168 3 2" NPT 18 9 FIGURE 2 2 thru 61NCH (DN50 thru DN950) RISER MANIFOLD ASSEMBLYAND DIMENSIONS Page 4 of 6 TFP962 SWITCH TERMINAL CONNECTIONS UNINSULATED CLAMPING SEVERED LOOPED SECTION CAUTION: PLATE STRIPPED SINGLE An uninsulaled section of a TERMINAL CONDUCTOR single conductor is not permitted to be looped around ENDS SEPARATE CONDUCTORS CLAMPING the terminal and serve as two PLATE separate connections. The TERMINAL wire must be severed to serve INCOMING as two separate connections, thereby providing supervision of the connection in the event that the wire becomes dislodged from the terminal. OUTGOING IMPROPER CONNECTION METHOD PROPER CONNECTION METHOD WATERFLOW SWITCH TYPICAL ELECTRICA CONNECTIONS CONTACTS .......... SPDT (Form C) LOCAL END OF LINE CONTACT RATING .... 5A @ 125 VAC SIGNAL 2.5A @ 30 VDC DEVICE RNO RESISTOR NC NC NO NO • NC COM COM COM CONTROL POWER PANEL NO FLOW NON -SUPERVISED STYLE BICLASS B CONDITION CIRCUIT SUPERVISED CIRCUIT (SEE NOTE) NOTE: For supervised circuits, see "Switch Terminal Connections" above. The WaterflowAlann Switch has two switches, one can be used to operate a central station, proprietary or remove signaling unit, while the other contact is used to operate a local audible or visual annunciator. COVER TAMPER SWITCH (ULC ASSEMBLIES ONLY) CONTACTS .......... SPDT (Form C) CONTACT RATING .... 3A @ 250 VAC 5A @ 125 VAC 1mA @ 5 VDC min. NO % • NC COM CONTACTS SHOWN WITH COVER IN PLACE FIGURE 3 WIRING GUIDANCE TFP962 Page 5 of 6 o ins NO. DESCRIPTION QTY. P/N NO. DESCRIPTION CITY. P/N T(DN40) Manifold Only; To ins(DN40) optional Pressure Relief Trim on 1 3/8" Copper Tubing, 2 Pressure Relief Valve, a 1-112" (DN40) Manifold, a 1/2" NPT outlet 2" (DN50) Manifolds .... 1 971-124-01 175 psi, Nonadjustable .. 1 198-066-00 must be provided by the installer on the 2-1/2" (DN65) and 3 90" Compression Filling system outlet piping, and a connection back 3" DN80 Manifolds ... 1 971-124-02 Fitting to the manifold drain trim must be fabricated 4" (DN100) and 4 1" x 1/2" Reducing Hex with installer supplied 3/8" copper tubing. 6" DN150 Manifolds ... 1 971-124-03 Bushing Discard unused trim componen1s. Care and Maintenance The following inspection procedure must be performed as indicated, in ad- dition to any specific requirements of the NFPA, and any impairment must be immediately corrected. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The in- stalling contractor or product manufac- turer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. NOTES No attempt is to be made to repair any N65), 0), or Did CH: Common Hardware 3 1/2" NPT Installer Outlet Provided System Outlet Piping Installer Fabricated 2 " p 3/8" Copper Tubing4 9 Manifold Drain Trim 1-1/2" (DN40) Manifold NO FIGURE 4 OPTIONAL PRESSURE RELIEF VALVE Riser Manifold component in the field. Only the pressure gauge, waterflow alarm switch, or relief valve can be replaced. If any other problems are encountered the entire riser manifold must be replaced. The alarm/flow test procedure will re- sult in operation of the associated alarms. Consequently, notification must be given to the owner and the fire department, central station, or other signal station to which the alarms are connected, and notification must be given to the building occupants. Before closing a fire protection system control valve for inspection or mainte- nance work on the fire protection sys- tem that it controls, permission to shut down the effected fire protection Sys- tem must first be obtained from the proper authorities and all personnel who may be affected by this action must be notified. After placing a fire protection system in service, notify the proper authorities and advise those responsible for moni- toring proprietary and/or central sta- tion alarms. Alarm/Flow Test Procedure Step 1. Place the test & drain Valve in the "test" position. Step 2. Fully open the drain valve. Make certain that drainage water will not cause any damage or injury. Step 3. Verify operation of associated alarms. Step 4. Close the drain valve. Step 5. Place the test & drain Valve in the "drain" position. Step 6. Verify that the residual (flow- ing) pressure indicated by the pres- sure gauge is no less that originally recorded for the system when it was first installed. Step 7. Close the drain valve. Step 8. Verify that the static (not flow- ing) pressure indicated by the pres- sure gauge is no less that originally recorded for the system when it was first installed. Page 6 of 6 TFP962 Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Information Riser Manifold: Specify; Size (specify), Figure 513, (specify connection type inlet x outlet) Riser Manifold (specify - without or with) a cover tamper switch for the waterflow alarm switch, PIN (specify). NOTES Orders for Figure 513 may be filled with a Figure 13, The two assemblies are completely interchangeable in function, application, and end -to -end laying length. If a ULC Listing is required, the Riser Manifold must be ordered with a cover tamper switch for the waterflow alarm switch. ULIULCIFM Assemblies With Cover Tamper Switch 1-1/2 Inch (DN40) MT x FT .............. P/N 4086 1-1/2 Inch (DN40) MT x MT .............. PIN 4087 2 Inch (DN50) G x G ................ PIN 4090 2-1/2 Inch (DN65) G x G ................ PIN 4091 3 Inch (DN80) G x G ................ PIN 4092 4 Inch (DN100) G x G ................ PIN 4095 6 Inch (DN150) G x G ................ P/N 4096 UL/FM Assemblies Without Cover Tamper Switch 1-112 Inch (DN40) MT x FT .............. P/N 4055 1-1/2 Inch (DN40) MT x MT .............. P/N 4056 2 Inch (DN50) G x G ................ PIN 4060 2-1/2 Inch (DN65) G x G ................ P/N 4061 3 Inch (DN80) G x G ................ PIN 4062 4 Inch (DN100) G x G ................ PIN 4065 6 Inch (DN150) G x G ................ PIN 4066 Optional Pressure Relief Valve: Specify: Operational Pressure Relief Valve and Trim for use with (specify size) Figure 513 or 13 Series Riser Manifold, PIN (specify). 1-1/2"or2................. PIN 4063 2-1/2"or3................. PIN 4072 4"or6.................... PIN 4073 Replacement Parts: Specify: (description) for use with Fig- ure 513 or 13 Riser Manifold, PIN (Ref. Figure 1 or 2, as applicable). TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 tqco Dire & Building ,products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 www.tyco-fire.com Tyco Fire Products Model CV-1 F Check Valve General Description Q FM4 , . &Cq See Fire Protection � , Submittal Sheet for Pressure Rating and Listing/Approval Information The Model CV-1 F Fire Protection Check Valve is furnished with grooved ends and can be installed using grooved couplings. The Model CV-1 Fcan be installed withANSI class 150 Flanges utilizing Grinnell Figure 71 flange adapters and also ANSI class 300 Flange Adapters. All Model CV-1F Check Valves have been designed with a removable coverfor ease of field maintenance. Valves installed horizontally or inclined (flow up or down) are to be positioned with the cap facing up. Valves installed vertically may be positioned with flow up or down. A Maintenance Check Valve IGt is available to allow the maintenance procedure of backflushingth rough the fire department connection without removing the Model CV-1 F Check Valve from the pipe line. The Model CV-1 F Check Valves are a redesignation forthe Central Fig ure 59OF and Grinnell Figure 590F. WARNING The Model Cl/ -IF Check Valve described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the performance of this device. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturershouldbecontacted withanyques6ons. Technical Data Model: CV-1 F Sizes: 2", 21/2", 76.1 mm, 3", 4",139.7mm, 5", 165.1 mm, 6", 8",10" and 12" Max. Working Pressure: 300 psi (2068 kPa) Factory Hydro Test: 100%at 600 psi (4137 kPa) -Seatand shell complies with test req ui rements of MSS SP-71, UL, FM and ULC Approvals: UL, FM and ULC; See Fire Protection Submittal Sheet for exact Listing / Approval information. Body and Cap: Ductile iron conforming to ASTM A-536, Grade 65-45-12 Clapper: Stainless Steel (2" - 8") or Ductile Iron (10" and 12") Seal: Grade "E" EPDM Protective Coatings: Valve assembly • Non -lead paint Ordering Procedure When placing an order, indicate the full product name. Please specify the quantity, valve model number, size, type of seal, Grade "E" EPDM, and part number from the following list. Valve Valve Size Part Number 2" 59-590-0-020 2'/2" 59-590-0-025 76.1 m m 59-590-0-076 3" 59-590-0-030 4" 59-590-0-040 139.7mm 59-590-0-139 5" 59-590-0-050 165.1 mm 59-590-0-165 6" 59-590-0-060 8" 59-590-0-080 10, 59-590-0-100 12" 59-590-0-120 Tyco Fire Products, valves, accessories and other productsare availableth roug houtthe U.S., Canada, and internationally, through a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. Limited Warranty Products manufactured by Tyco Fire Products are warranted solelyto the original Buyer forten (10) years againstdefects in material and workmanship when paid forand properlyinstalled and maintained under normal useand service. This warrantywill expireten (10)years from date of shipment by Tyco Fire Products. No warranty is given for products or components manufactured bycompaniesnotaffiliated byownership with Tyco Fire Products orforpmductsandcomponents which have beensubjectto misuse, i mproperinstallation, corrosion, orwhich have notbeen installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), and/orthe standards of any otherAuthorities Having Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neitherassumes, nor authorizes any person to assume for it, any other obligation in connectionwrth the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDERANYOTHER LEGALTHEORY, FOR INCIDENTAL, INDIRECT, SPECIALOR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THEFOREGO/NG WARRANTYISMADEINL/EUOF ANYANDALL OTHER WA RRANTIESEXPRESSOR IMPLIED INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, Page 1 of 2 September 2004 TFP1550 Page 2 of 2 TFP1550 Model CV-1 F Check Valve Nominal Dimensions Approx. Size A B C D E F J Cover Weight Inches Inches Inches Inches Inches Inches Inches Inches Bolt Torq. lbs. mm mm mm mm mm mm mm mm Lb.-R./Nm Kg, 2" 6.75 4.38 2.55 2.57 3.25 4.75 1.62 15 9.0 60.3 171.5 111.3 64,8 65.3 82,3 120.7 41.5 21 4.5 2'/2" 8.00 5.80 3.41 3.40 3.88 6.00 1.70 39 10.0 73, 0 203.2 147.3 86.6 86.4 98.6 152.4 43.2 54 4.5 8.00 5.80 3.41 3.40 3.88 6.00 1.70 39 10.00 76.1 mm 203.2 147.3 86.6 86.4 98.6 152.4 43.2 54 4.5 3" 8.37 5.76 3.60 3.40 3.88 6.00 1.70 39 11.0 88.9 212.6 1.46.3 91.4 86.4 98.6 152.4 43.2 54 5.0 4" 9.63 6.74 4.61 3.63 4.56 7.13 1.84 39 25.0 114.3 244.6 171.2 117.1 92.2 115.1 181.1 46.7 54 11.3 10.50 7.50 5,29 4.20 4.90 7.60 1.90 39 29.0 139.7mm 266.7 190,5 134,4 106.7 124.5 193.0 48.3 54 13.2 5" 10.50 7.50 5.29 4.20 4.90 7.60 1.90 39 29.0 141.3 266.7 190.5 134.4 106.7 124.5 193.0 48.3 54 13.2 11.50 80.5 5.75 4.50 5.00 7.60 1.48 60 47.0 165,1 292.1 204.5 146,1 114.3 127.0 193.0 37.6 82 21.3 6" 11.50 8.05 5.75 4.50 5.00 7.60 1.48 60 47.0 168.3 292.1 204.5 146.1 114.3 1270 193.0 376 82 21.3 8" 14.00 10.25 7.75 5.62 5.45 8.40 2.20 120 66.0 219.1 355.6 260.4 196.9 142.7 138.41 213.4 58.9 1 164 29.9 10" 18.00 13.00 10.21 6.38 7.50 10.50 3.00 120 109.7 273.0 4572 330.2 259.31 162.1 190.5 266.7 76.2 164 49.4 12" 21.0 14.28 11.31 7.26 7.62 10.62 2.75 120 151.0 323.9 533.4 362.7 287.2 184.4 193.5 269.7 69.9 164 68.0 FLOW RATE (LPM) FLUW HAI L (UPM) Note: It is good piping practice to apply a safety factor of 15 % to 20 % to the values in the above table for design purposes. General Notes: It is the Designer's responsibility to select products suitable for the intended service and to ensure ISO that pressure ratings and performance data is not exceeded. Always read and understand the installation 9001 instructions (I1-1-1000). Never remove any piping component or corrector modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. Certified Company TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19946 Printed U.S.A. Detail Part Material Qty. 1 Body Ductile Iron 1 2 Cap Ductile Iron 1 3 Gasket Synthetic Fiber 1 4 Hex Cap Screw Steel, Zinc Plated AR 5 Clapper Stainless Steel or Ductile Iran 1 6 Seal Facing EPDM Grade "E" 1 7 Spring Stainless Steel 1 8 Hinge Shaft Stainless Steel 1 9 Retaining Ring Stainless Steel AR 10 Washer Teflon 2 11 Retention Bolt Stainless Steel 1 12 Seal Ring Neoprene 1 13 Retaining Disc Stainless Steel 1 14 Locknut Stainless Steel 1 15 Plug'/2"-14 NPT Cast Iron 2 16 Adhesive Thread Sealer AR 17 Nameplate Aluminum 1 18 1 Rivet Steel 2 Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicable standards ofthe National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractor or product manufacturer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. - tqCD Fire & Building Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Series TY-FRB — 2.8, 4.2, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright and Pendent Sprinklers described in this data sheet are quick response - standard cover- age, decorative 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, etc. The recessed version of the Series TY-FRB Pendent Sprinkler, where ap- plicable, is intended for use in areas with a finished ceiling. It uses either a two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Es- cutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a two-piece Style 20 (1/2 inch NPT) or Style 30 (3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjust- ment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pen- dent position. The adjustment pro- vided by the Recessed Escutcheon re- duces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 10 tained when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level versions of the Series TY-FRB Pendent Sprinklers are detailed in Technical Data Sheet TFP356, and Sprinkler Guards are de- tailed in Technical Data Sheet TFP780 WARNINGS The Series TY-FRB Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. MARCH, 2007 Model/Sprinkler Identification Numbers TY1131 - Upright 2.8K, 1/2"NPT TY1231 - Pendent 2.8K, 1/2"NPT TY2131 - Upright 4.21K, 1/2"NPT TY2231 - Pendent 4.21K, 1/2"NPT TY3131 - Upright 5.61K, 1/2"NPT TY3231 - Pendent 5.6K, 1/2"NPT TY4131 - Upright 8.OK, 3/4"NPT TY4231 Pendent 8.01K, 3/4"NPT TY4831- Upright 8.01K, 1/2"NPT TY4931- Pendent 8.OK, 1/2"NPT TFP171 Page 2 of 10 ESCUTCHEON PLATE SEATING SURFACE 2-1/4" (57,2 mm) L 1-9/16" (39,7 mm) �f SSP DEFLECTOR* 7/16" (11,1 mm) STYLE 10 or 20 1/2" NOMINAL RECESSED NPT MAKE -IN ESCUTCHEON PENDENT 2-7/8"(73,0 mm) DIA. SSU* DEFLECTOR 7/16" (11,1 mm) NOMINAL MAKE -IN 2-3/16" WRENCH (55,6 mm) FLATS 1/2" NPT RECESSED PENDENT UPRIGHT TFP171 CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression 7 - Bushing orifice seat on frame. Screw FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY1131) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 112 INCH NPT ESCUTCHEON PLATE SEATING SURFACE 2-3/16" (55,6 mm) 1-1/2" (38,1 mm) m SSP DEFLECTOR * 7/16" (11,1 mm) STYLE 10 or 2( 1/2" NOMINAL RECESSED „ _ MAKE -IN ESCUTCHEON PENDENT I� 2-7/8" (73,0 mm) DIA. SSU* DEFLECTOR 6* 7/16" 5 (11,1 mm) NOMINAL 4 MAKE -IN 2-3/16" 2 ;H (55,6 mm) i 112" NPT 3 1 RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 112 INCH NPT TFP171 ESCUTCHEON PLATE SEATING SURFACE 2-3/16" (55,6 mm) 1-1/2" (38,1 mm) 1/2" NPT 7/16" (11,1 mm) NOMINAL MAKE -IN SSP DEFLECTOR * F— 2-7/8" (73,0 mm) DIA. STYLE 10 or 20 RECESSED ESCUTCHEON SSU* DEFLECTOR 7/16" (11,1 mm) NOMINAL MAKE -IN 2-3/16" WRENCH (55,6 mm) FLATS 1/2" NPT PENDENT RECESSED PENDENT UPRIGHT Page 3 of 10 CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 112 INCH NPT ESCUTCHEON 1/2" (12,7 mm) PLATE SEATING NOMINAL SURFACE NPT MAKE -IN -r— — I --i 2-5/16" (58,7 mm) 1-9/16" (39,7 mm) STYLE 30 or 40 RECESSED ESCUTCHEON SSU* DEFLECTOR WRENCH FLATS SSP DEFLECTOR* 2-7/8" (73,0 mm) DIA. 3/4" NPT PENDENT RECESSED PENDENT UPRIGHT 1/2" (12,7 mm) NOMINAL MAKE -IN m (57,2 mm) CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 314 INCH NPT Page 4 of 10 7116" (11,1 mm) 1/21, NOMINAL NPT MAKE -IN 2-1/4" (57,2 mm) 1-9/16" WRENCH (39,7 mm) FLATS SSP* DEFLECTOR PENDENT 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector 2 - Button Assembly 5 - Compression Screw TFP171 SSU* DEFLECTOR CROSS UPRIGHT SECTION * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS 8.0 K-FACTOR, 112 INCH NPT Technical Data Approvals UL and C-UL Listed. FM, LPCB, and NYC Approved. (Refer to Table A and B for complete approval information including corro- sion resistant status.) Maximum Working Pressure Refer to Table C. Discharge Coefficient K = 2.8 GPM/psil/2 (40,3 LPM/barl/2) K = 4.2 GPM/psi112 (60,5 LPM/bar'/2) K = 5.6 GPM/psil/2 (80,6 LPM/barl/2) K = 8.0 GPM/psil/2 (115,2 LPM/barl/2) Temperature Ratings Refer to Table A and B Finishes Sprinkler: Refer to Table A and B. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical Characteristics Frame . . . . . . . . . . . Bronze Button . . . . . . Brass/Copper Sealing Assembly . . . . . . Beryllium Nickel w/Teflont Bulb . . . . . . . . . . Glass Compression Screw . . . . . Bronze Deflector . . . Copper/Bronze Bushing (K=2.8) . . . . . . . Bronze Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TY-FRB Pendent and Up- right Sprinklers are intended for fire protection systems designed in ac- cordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Pre- vention Data Sheets ). Only the Style 10, 20, 30, or 40 Recessed Escutch- eon, as applicable, is to be used for recessed pendent installations. TFP171 Page 5 of 10 SPRINKLER FINISH (See Note 7) K TYPE TEMP. BULB NATURAL CHROME I WHITE*** LIQUID BRASS PLATED POLYESTER 135°F/57°C Orange PENDENT (TY1231) and 1, 2, 3, 5 155°F/68°C Red 175°F/79°C Yellow UPRIGHT 200°F/93°C Green 2.8 1/2" (TY1131) 286°F/141 °C Blue NPT 135°F/57°C Orange RECESSED PENDENT 155°F/68°C Red 175°F/79°C Yellow (TY1231)* Figure 6 200°F/93°C Green 1, 2, 5 135°F/57°C Orange RECESSED PENDENT 155°F/68°C Red 175°F/79°C Yellow (TY1231)** Figure 7 200°F/93°C Green 135°F/57°C Orange PENDENT (TY2231) 155°F/68°C Red 175°F/79°C Yellow and UPRIGHT 200'F/93°C Green 4.2 1/2" (TY2131) 1,2 286°F/141°C Blue 135°F/57°C Orange NPT RECESSED PENDENT 155°F/68°C Red. 175°F/79°C Yellow (TY2231)* Figure 8 200°F/93°C Green 135°F/57°C Orange RECESSED PENDENT 155°F/68°C Red 175°Ff79°C Yellow (TYYY31)** Figure 9 200°F/93°C Green NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Re- sponse Sprinklers. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprin- klers. 5. Approved by the City of New York under MEA 354-01-E. 7. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprin- klers are UL and C-UL Listed as Corrosion Resistant Sprinklers. ` Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (112" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. *** Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS 2.8 AND 4.2 K-FACTOR SPRINKLERS Page 6 of 10 TFP171 SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB NATURAL I CHROME I WHITE*** LEAD LIQUID BRASS I PLATED POLYESTER COATED 135°F/57°C Orange PENDENT (TY3231) and 1, 2, 3, 4, 5, 6, 7 1, 2, 3, 5 155°F/68°C Red 175°F/79°C Yellow UPRIGHT 200°F/93'C Green 5.6 (TY3131) 286°F/141°C Blue 1/2" NPT 135°F/57°C Orange RECESSED PENDENT (TY3231)* 1, 2, 4, 5 N/A 155°F/68°C Red 175°F/79°C Yellow Figure 10 200°F/93°C Green 135°F/57°C Orange RECESSED PENDENT (TY3231)** 1, 2, 3, 4, 5 1, 2, 4, 5 N/A 155°F/68°C Red 175°F/79°C Yellow Figure 11 200°F/93°C Green 135°F/57°C Orange PENDENT (TY4231) and 1, 2, 3, 4, 5, 6,7 1, 2, 5 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green UPRIGHT 8.0 (TY4131) 286°F/141 °C Blue 3/4" NPT 135°F/57°C Green RECESSED PENDENT (TY4231)* 1, 2, 4, 5 N/A 155°F/68°C Orange 175°F/79°C Red Figure 12 200°F/93°C Yellow 135°F/57°C Orange RECESSED PENDENT (TY4231)** 1, 2, 3, 4, 5 N/A 155°F/68°C Red 175°F/79°C Yellow Figure 13 200°F/93°C Green 135°F/57°C Orange B.0 1/2" PENDENT (TY4931) and 1, 2, 4, 5, 6 1, 2, 5 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green NPT UPRIGHT (TY4831) 286°F/141°C Blue NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers, 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. 4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers; however, the LPCB does not rate the thermal sensitivity of recessed sprinklers. 5. Approved by the City of New York under MEA 354-01-E. 6. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377). 7. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. 8. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. Installed with Style 10 (112" NPT) or Style 40 (3/4" NPT) 314" Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. *'* Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS 5.6 AND 8.0 K-FACTOR SPRINKLERS TFP171 Page 7 of 10 SPRINKLER FINISH K TYPE NATURAL CHROME WHITE LEAD BRASS PLATED POLYESTER COATED PENDENT (TY3231) and 2.8 UPRIGHT (TY3131) 175 PSI (12,1 BAR) N/A 112 RECESSED PENDENT NPT (TY323) PENDENT (TY4231) and 4.2 UPRIGHT (TY4131) 175 PSI (12,1 BAR) N/A 314 RECESSED PENDENT NPT (TY4231) PENDENT (TY3231) and 250 PSI (17,2 BAR) 175 PSI (12,1 BAR) 5.6 UPRIGHT (TY3131) OR 1/2 175 PSI (12,1 BAR) RECESSED PENDENT NPT (TY3231) (SEE NOTE 1) N/A PENDENT (TY4231) and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) 8.0 UPRIGHT (TY4131) 3/4" RECESSED PENDENT NPT (TY4231) N/A 8.0 PENDENT (TY4931) 1/2" and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) NPT UPRIGHT(TY4831) NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and , the Approval by the City of New York. TABLE C, MAXIMUM WORKING PRESSURE Installation The Series TY-FRB Sprinklers must be installed in accordance with the fol- lowing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1116 inch (1, 6 mm) for the 135°F/57'C to 3132 inch (2,4 mm) for the 286°F/141 °C temperature ratings. A leak tight 112 inch NPT sprinklerjoint should be obtained with a torque of 7 to 14 ft.tbs. (9,5 to 19,0 Nm). A maxi- mum of21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 112 NPT connections. A leak tight 314 inch NPT sprinkler joint should be ob- tained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40,7 Nm) of torque is to be used to install sprinklers with 314 NPT con- nections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over -tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY-FRB Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 14). With reference to Figures 1, 2, 3, 4, and 5, the W-Type 6 Sprinkler Wrench is to be applied to the sprinkler wrench flats. The Series TY-FRB Recessed Pen- dent Sprinklers must be installed in accordance with the following instruc- tions. Step A. After installing the Style 10. 20, 30, or 40 Mounting Plate, as appli- cable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprin- kler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 15). With reference to Figure 1, 2, 3, and 4, the W-Type 7 Recessed Page 8 of 10 2-7/8" DIA. 5/8±1/4" (73,0 mm) 3/4" (19,1 mm) (15,9±6,4 mm) 1/4" 6,4 mm 2-1/4" DIA. ( ) FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE FITTING L I (3,2 mm) MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33.3 mm) TY-FRB 13/16" (20,6 mm) FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 112 INCH NPT 2-7/8" DIA. 5/8±1/4" (73,0 mm) 3/4" (19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE FITTING (3,2 mm) MOUNTING SURFACE CLOSURE SERIES 1-1/4" (31,8 mm) TY-FRB 3/4" (19,1 mm) FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 112 INCH NPT Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The Series TY-FRB Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance TFP171 2-718" DIA. 1/2±1/8" (73,0 mm) 1/2" (12,7 mm) (12,7±3,2 mm) 2-1 /4" DIA. 114" (6,4 mm) FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE FITTING 1/8" (3,2 mm) MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TY-FRB 1-1/16" (27,0 mm) FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 112 INCH NPT 2-7/8" DIA. (73,0 mm) (12,7±3,2 mm) 2-1/4" DIA. 114" (6,4 mm) FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE FITTING 1/8" (3,2 m) MOUNTING SURFACE CLOSURE SERIES 1-1/4" (31,8 mm) TY-FRB 1" (25,4 mm) FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 112 INCH NPT work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. The owner must assure that the sprin- klers are not used for hanging of any objects; otherwise, non -operation in the event of a fire or inadvertent opera- tion may result. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- TFP171 2-7/8" DIA. 5/8±1/4" (73,0 mm) 3/4" (19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE FITTING 1/8" (3,2 mm) MOUNTING SURFACE CLOSURE SERIES 1-1/4" (31,8 mm) TY-FRB 3/4" (19,1 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 112 INCH NPT 2-7/8" DIA. 5/8+1/4" (73,0 mm) 3/4" (19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE FITTING 1/8'. (3,2 mm) MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm TY-FRB 13/16" (20,6 mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 314 INCH NPT pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- Page 9 of 10 _ 2-718" DIA. (73,0 mm) (12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) FACE OF (57*R' 2 mm) OUNTING SPRINKLEPLATE FITTING MOUN SURFACE CLOSURE SERIES 1-1/4" 31,8 mm) TY-FRB 1" (25,4 mm) FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 112 INCH NPT 2-718" DIA. 1/2±1/8" (73,0 mm) 1/2" (12,7 mm) (12,7±3,2 mm) 2-1/4" DIA. 114" (6,4 mm) (57,2 mm) FACE OF MOUNTING SPRINKLER PLATE FITTING / 1/8" (3 2 mm) i J MOUNTING SURFACE CLOSURE SERIES TY-FRB 1-5/16" 33,3 mm 1-1/16" (27.0 mm) FIGURE 13 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 314 INCH NPT WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 14 W-TYPE 6 SPRINKLER WRENCH facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified WRENCH RECESS 4 PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 15 W-TYPE 7 RECESSED SPRINKLER WRENCH Inspection Service in accordance with local requirements and/or national codes. Page 10 of 10 P/N 57 - XXX - X - XXX MODEL/SIN 330 2.8K UPRIGHT (1/2"NPT) TY1131 331 2.8K PENDENT (1/2"NPT) TY1231 340 4.2K UPRIGHT (1/2"NPT) TY2131 341 4.2K PENDENT (1/2"NPT) TY2231 370 5.6K UPRIGHT (1/2"NPT) TY3131 371 5.6K PENDENT (1/2"NPT) TY3231 390 8.OK UPRIGHT (3/4"NPT) TY4131 391 8.OK PENDENT (3/4"NPT) TY4231 360 8.OK UPRIGHT (1/2"NPT) TY4831 361 8.OK PENDENT (1/2"NPT) TY4931 Limited Warranty TFP171 SPRINKLER I 135 155 175 200 286 RATING 135°F/57°C 1 NATURAL BRASS 155°F/68°C 4 WHITE POLYESTER 175°F/79°C 3 WHITE (RAL9010)* 200°F/93°C 9 CHROME PLATED 286°F/141°C 7 LEAD COATED * Eastern Hemisphere sales only. TABLE D PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsiblefor sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. I;�_ress or including warranties This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Refer to the Price List for complete listing of Part Num- bers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), Quick Response, (specify K-factor), (specify temperature rating), Series TY-FRB (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table D). Recessed Escutcheon: Specify: Style (10, 20, 30, or 40) Re- cessed Escutcheon with (specify*) fin- ish, P/N (specify*). * Refer to Technical Data Sheet TFP770. Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 tqCJ3 Fire & Building Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Series RFI► — 5.6 K-factor "Royal Flush 1111 Pendent Concealed Sprinklers Quick & Standard Response, Standard Coverage General Description The Series RFII Quick Response (3 mm bulb) & Standard Response (5 mm bulb), 5.6 K-Factor, "Royal Flush II" Concealed Pendent Sprinklers are decorative sprinklers featuring a flat cover plate designed to conceal the sprinkler. It is the best choice for archi- tecturally sensitive areas such as hotel lobbies, office buildings, churches, and restaurants. Each unit includes a Cover Plate As- sembly that conceals the sprinkler op- erating components above the ceiling. The separable two-piece design of the Cover Plate and Support Cup Assem- blies allows installation of the sprin- klers and pressure testing of the fire protection system prior to installation of a suspended ceiling or application of the finish coating to a fixed ceiling. They also permit removal of sus- pended ceiling panels for access to building service equipment without having to first shut down the fire pro- tection system and remove sprinklers. Also, the separable two-piece design of the the Sprinkler provides for 1/2 inch (12,7 mm) of vertical adjustment, to reduce the accuracy to which the length of fixed pipe drops to the sprin- klers must be cut. The Series RFII Sprinklers are shipped with a Disposable Protective IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 Cap. The Protective Cap is temporarily removed for installation, and then it can be replaced to help protect the sprinkler while the ceiling is being in- stalled or finished. The tip of the Pro- tective Cap can also be used to mark the center of the ceiling hole into plas- ter board, ceiling tiles, etc. by gently pushing the ceiling product against the Protective Cap. When the ceiling in- stallation is complete the Protective Cap is removed and the Cover Plate Assembly installed. As an option, the Series RFII Standard Response (5 mm bulb) "Royal Flush II" Concealed Pendent Sprinklers may be fitted with a silicone Air and Dust Seal (Ref. Fig. 5). The Air and Dust Seal is intended for sensitive areas where it is desirable to stop air and dust travel through the cover plate from the area above the ceiling. WARNINGS The Series RFII Concealed Pendent Sprinklers described herein must be installed and maintained in compli- ance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the per- formance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices fn proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers TY3551 (5mm bulb) & TY3531 (3 mm bulb): maximum 175 psi (12,1 bar) by UL, C-UL, FM, LPCB and NYC. TY3504 (5 mm bulb) & TY3505 (3 mm bulb): maximum 250 psi (17,3 bar) by JULY, 2004 0 UL, C-UL, and NYC. Maximum 175 psi (12,1 bar) by FM. Technical Data Approvals for Series RFII UL and C-UL Listed. FM Approved. NYC under MEA 353-01-E. LPCB (Ref. No. 094a/09 for TY3551 & 094a/10 for TY3531) Approved. The approvals apply only to the serv- ice conditions indicated in the Design Criteria section and maximum pres- sure ratings indicated in the Model/Sprinkler Identification Num- bers section. Approvals for Air & Dust Seal (Part #10908100) UL and C-UL Listed for use with the RFI I (TY3551 & TY3504) Standard Re- sponse Concealed Sprinkler. Temperature Ratings 155F/68C Sprinkler - 135F/57C Plate 200F/93C Sprinkler - 165F/74C Plate Discharge Coeffi lent K = 5.6 GPM/psis/z (80,6 LPM/bar1/2) Adjustment 1/2 inch (12,7 mm) Finishes Cover Plate: Chrome Plated, Brass Plated, or White Painted (Custom paint matches and colors other than white are available on request.) TFP181 Page 2 of 4 Physical Characteristics Frame . . . . . . . . . . Bronze Support Cup . Chrome Plated Steel Guide Pins . . . . . . Stainless Steel Deflector . . . . . . . . . Bronze Compression Screw . . .. . . Brass Bulb . . . . . . . . . . . .. . . Glass Cap . . . Bronze or Copper Sealing Assembly . . . Beryllium Nickel w/Teflon' Cover Plate . . . . . . ... . . Brass Retainer . . . . . Brass Ejection Spring . . . . Stainless Steel Patents U.S.A. 4,014,388 Operation When exposed to heat from a fire, the Cover Plate, which is normally sol- dered to the Retainer at three points, falls away to expose the Sprinkler As- sembly. At this point the Deflector sup- ported by the Guide Pins drops down to its operational position. The glass Bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, activating the sprinkler and allowing water to flow. Design Criteria The RFII (TY3551 & TY3504), 5 mm Bulb Type, Concealed Pendent Sprin- klers are UL and C-UL Listed as stand- ard response - standard spray sprin- klers for use in accordance with the current NFPA standard. They are FM Approved as standard response - standard spray sprinklers for use in accordance with the current FM Loss Prevention Data Sheets. The RFII (TY3531 & TY3505) 3 mm Bulb Type, Concealed Pendent Sprin- klers are UL and C-UL Listed as quick response - standard spray sprinklers for use in accordance with the current NFPA standard. They are FM Ap- proved as standard response - stand- ard spray sprinklers for use in accord- ance with the current FM Loss Prevention Data Sheets. The Series RFII Concealed Pendent Sprinklers are only listed and ap- proved with the Series RFII Concealed Cover Plates having a metallic or white painted finish. The Series RFII must not be used in applications where the air pressure above the ceiling is greater than that below. Down drafts through the Sup- port Cup could delay sprinkler opera- tion in a fire situation. TFP181 1/2` NPT SEALING ASSEMBLY FRAME CAP SUPPORT CUP WITH BULB ROLLFORMED THREADS COMPRESSION SCREW GUIDE PINS (2) DEFLECTOR (DROPPED DEFLECTOR i_r-- --_li `�- �/ POSITION) I I SPRINKLER/SUPPORT CUP ASSEMBLY THREAD INTO RETAINER SUPPORT CUP O WITH THREAD UNTIL MOUNTING O DIMPLES SURFACE IS FLUSH WITH EJECTION CEILING SPRING SOLDER COVER TABS (3) COVER PLATE/RETAINER PLATE ASSEMBLY FIGURE 1 SERIES RFII CONCEALED SPRINKLER ASSEMBLY Installation The Series RFII must be installed in accordance with the following instruc- tions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1116 inch (1,6 mm) for the 155°F/68°C and 3132 inch (2,4 mm) for the 200°F/93°C tem- perature ratings. A leak tight 112 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft.lbs. (28,5 Nm) of torque is to be used to install sprinklers. Higher levels of torque may distort the sprinkler inlet with consequent leak- age or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in the Sprinkler Assembly by under- or over -tightening the Sprinkler/Support Cup Assembly. Readjust the position of the sprinkler fitting to suit. Step 1. The sprinkler must only be installed in the pendent position and with the centerline of the sprinkler per- pendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 4. Wrench tighten the sprinkler using only the RFII Sprinkler Wrench (Ref. Figure 3). The RFII Sprinkler Wrench is to be applied to the Sprin- kler as shown in Figure 3. Step 5. Replace the Protective Cap (Ref. Figure 4) by pushing it upwards until it bottoms out against the Support Cup. The Protective Cap helps prevent damage to the Deflector and Arms dur- ing ceiling installation and/or during application of the finish coating of the ceiling. It may also be used to locate the center of the clearance hole by gently pushing the ceiling material up against the center point of the Protec- tive Cap. NOTE As long as the Protective Cap remains in place, the system is considered to be "Out of Service". ' Registered Trademark of DuPont TFP181 FACE OF SPRINKLER FITTING SPRINKLER SUPPORT CUP ASSEMBLY 1/2" (12,7 mm) THREADED D ADJUSTMENT FACE OF CEILING, RETAINING RING MOUNTING SURFACE CLEARANCE HOLE DIAMETER - DIMENSION C A_Ir ------ I_Ir L �L 3/16" to 11/16" MANUFACTURER DEFLECTOR (4,8 to 17,5 mm) PRESET GAP IN DROPPED REFERENCE 3132" (2,4 mm) POSITION COVER PLATE PROFILE DEPTH DIMENSION B COVER PLATE DIAMETER DIMENSION A COVER PLATE RETAINER ASSEMBLY A: 3-1/4" (82,6 mm) C: 2-3/8" to 2-5/8" (60,3 to 66,7 mm) B: 3/16" (4,8 mm) D: 1-3/4" to 2-1/4" (44,5 to 57,2 mm) FIGURE 2 SERIES RFII CONCEALED SPRINKLER INSTALLATION DIMENSIONS FRAME ARM SUPPORT CUP 7/8" (23 mm) SQUARE ALIGN J ARROWS WITH i FRAMEARMS al F ACCEPTS 0 1/2" SOCKET DRIVE FIGURE 3 RFII SPRINKLER WRENCH Page 3 of 4 CLEARANCE HOLE FIGURE 4 DISPOSABLE PROTECTIVE CAP Step 6. After the ceiling has been com- pleted with the 2-1/2 inch (63,5 mm) diameter clearance hole and in prepa- ration for installing the Cover Plate As- sembly, remove and discard the Pro- tective Cap, and verify that the Deflector moves up and down freely. If the Sprinkler has been damaged and the Deflector does not move up and down freely, replace the entire Sprin- kler assembly. Do not attempt to mod- ify or repair a damaged sprinkler. Step 7. When installing an Air and Dust Seal, refer to Figure 5, otherwise proceed to Step 8. To attach the Air and Dust Seal, verify the angle of the out- side edge of the seal is oriented ac- cording to Figure 5. Start the edge of the Retainer in the grooved slot of the Air and Dust Seal and continue around the retainer until the entire Air and Dust Seal is engaged. NOTE The Air and Dust Seal is only to be installed on the periphery of the Re- tainer. Step 8. Screw on the Cover Plate/Re- tainer Assembly until the Retainer - Figure 2 (or Air and Dust Seal - Figure 5) contacts with the ceiling. Do not continue to screw on the Cover Plate/Retainer Assembly such that it lifts a ceiling panel out of its normal position. If the Cover Plate/Retainer Assembly cannot be engaged with the Support Cup or the Cover Plate/Re- tainer Assembly cannot be engaged sufficiently to contact the ceiling, the Sprinkler Fitting must be repositioned. Care and Maintenance The Series RFII must be maintained and serviced in accordance with the following instructions: NOTES Absence of the Cover Plate Assembly may delay sprinkler operation in a fire situation. Page 4 of 4 When properly installed, there is a nominal 3132 inch (2,4 mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 2. This air gap is necessary for proper opera- tion of the sprinkler. If the ceiling is to be repainted after the installation of the Sprinkler, care must be exercised to ensure that the new paint does NOT seal off any of the air gap. Factory painted Cover Plates MUST NOT be repainted. They should be re- placed, if necessary, by factory painted units. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shutdown the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). If a sprinkler must be removed, do not reinstall it or a replacement without reinstalling the Cover Plate Assembly. If a Cover Plate Assembly becomes dislodged during service, replace it im- mediately. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH TFP181 DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' Lk ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. F MERCHANTABILITY AND FIT- ESS FOR A PARTICULAR PUR- OSE- Ordering Procedure When placing an order, indicate the full product name. Contact your local dis- tributor for availability. Sprinkler Assembly: Specify: (SIN), (specify temperature rating) Series RFII Concealed Pen- dent Sprinkler, P/N (specify). 155FI68C 200F/93C TY3551 51-790.1.155 51-790-1-200 TY3504 51-796.1.155 51-796-1-200 TY3531 51.792-1-155 51-792-1-200 TY3505 51-797.1.155 51-797-1-200 Separately Ordered Cover Plate: Specify: (specify temperature rating) Series RFII Concealed Cover Plate with (specify finish), P/N (specify). 135F/57C(a) 165Fr74C'(b) Brass 56-792.1-135 56-792-1-165 Bright Brass 56-792-2-135 56-792-2.165 Chrome 56-792.9.135 56-792-9-165 Brushed Chrome 56.792-8-135 56-792-8.165 White 56.792-0-135 56-792-0-165 White (RAL9010)' 56-792.3.135 56-792-3-165 Bright White 56-792-4-135 56-792.4.165 Off White 56-792-5.135 56-792-5-165 Black 56-792-6-135 56-792-6.165 Custom 56.792-X-135 56-792-X-165 (a) For use with 155F/68C sprinklers. (b) For use with 200F/93C sprinklers. ' Eastern Hemisphere sales only. Sprinkler Wrench: Specify: RFII Sprinkler Wrench, P/N 56-000-1-075, Air and Dust Seal: Specify: Air and Dust Seal, P/N 56-908-1-001. TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 tq00 Fire & Building Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Series DS-C — 5.6 K-factor Dry Pendent Concealed Sprinklers Quick & Standard Response, Standard Coverage General Description The Series DS-C, 5.6 K-factor, Quick Response (3 mm bulb) and Standard Response (5 mm bulb), Standard Cov- erage, Dry Pendent Concealed Sprinklers are decorative sprinklers featuring a flat cover plate designed to conceal the sprinkler. This type of sprinkler is typically used to provide a sprinkler drop from an unheated attic into an area where aesthetics is a con- cern, such as nursing homes, restau- rants, schools, etc. Each unit includes a Cover Plate As- sembly that conceals the sprinkler op- erating components above the ceiling. The separable two-piece design of the Cover Plate and Support Cup Assem- blies allows installation of the sprin- klers and pressure testing of the fire protection system prior to installation of a suspended ceiling or application of the finish coating to a fixed ceiling. They also permit removal of sus- pended ceiling panels for access to building service equipment without having to first shut down the fire pro- tection system and remove sprinklers. Also, the separable two-piece design of the Sprinkler provides for 1/2 inch (12,7 mm) of vertical adjustment. The Series DS-C Sprinklers are shipped with a Disposable Protective Cap. The Protective Cap is temporarily IMPORTANT Always refer to Technical Data Sheet TFP700 for the 'INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 removed for installation, and then it can be replaced to help protect the sprinkler while the ceiling is being in- stalled or finished. The tip of the Pro- tective Cap can also be used to mark the center of the ceiling hole into plas- ter board, ceiling tiles, etc. by gently pushing the ceiling product against the Protective Cap. When the ceiling in- stallation is complete the Protective Cap is removed and the Cover Plate Assembly installed. WARNINGS The Series DS-C Dry Pendent Con- cealed Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation, in addition to the standards of any other authorities having jurisdic- tion. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. The Series DS-C Dry Pendent Con- cealed Sprinklers must only be in- stalled in fittings that meet the require- ments of the Design Criteria section. Model/Sprinkler Identification Numbers TY3535 - (3 mm bulb) TY3555 - (5 mm bulb) APRIL, 2004 Technical Data Approvals for Series DS-C UL and C-UL Listed. (Refer to Design Criteria section.) Maximum Working Pressure 175 psi (12,1 bar) Inlet Thread Connection 1 inch NPT (Standard Order) ISO 7-R1 Discharge Coefficient K = 5.6 GPM/psis/2 (80,6 LPM/bars/2) Temperature Ratings 155°F/68°C Sprinkler/ 135°F/57°C Plate 200°F/93°C Sprinkler/ 165°F/74°C Plate Adjustment 1/2 inch (12,7 mm) Finishes Cover Plate: Chrome Plated, Brass Plated, or White Painted (Custom paint matches and colors other than white are available on request.) TFP515 Page 2 of 6 Physical Characteristics Inlet . . . . . . . . . . . . . . Copper Plug . . . . . . . . . . Copper Yoke .. . . Stainless Steel Casing . . Galvanized Carbon Steel Insert . . . . . . . . . Bronze Bulb Seat . . . . . . . Stainless Steel Bulb . . . . . . . . . . . . . . . Glass Deflector . . . . . . . . . . . Bronze Frame . . . . . . . . . Bronze Guide Tube . . . . . . Stainless Steel Water Tube . . . . . . Stainless Steel Spring . . . . . . Stainless Steel Sealing Assembly . . . . . . Beryllium Nickel w/Teflon' Support Cup . Chrome Plated Steel Guide Pins . . . . Stainless Steel Compression Screw . . . . . . Brass Cover Plate . . . . . . . . .. . Brass Retainer . . . . . Brass Ejection Spring . . . . Stainless Steel ' Registered Trademark of DuPont Patents U.S.A. Patent Number 5,188,185. Operation When the Series DS-C is in service, water is prevented from entering the assembly by the Plug & Belleville Seal- ing Assembly (Ref. Figure 1) in the Inlet of the Sprinkler. When exposed to heat from a fire, the Cover Plate, which is normally sol- dered to the Retainer at three points, falls away to expose the Sprinkler As- sembly. At this point the Deflector sup- ported by the Guide Pins drops down to its operational position. The glass Bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, and the Bulb Seat is re- leased. The compressed Spring is then able to expand and push the Water Tube as well as the Guide Tube outward. This action simultaneously pulls inward on the Yoke, withdrawing the Plug & Belleville Seal from the Inlet allowing the sprinkler to activate and flow water. TFP515 INLET PLUG WITH GASKETED SPRING PLATE SEAL YOKE WATER TUBE SPRING CASING INSERT GUIDE BULB TUBE SEAT VENT / HOLE , FRAME SUPPORT ,' -� BULB CUP WITH � ROLL FORMED THREADS COMPRESSION SCREW GUIDE PIN -- - - DEFLECTOR (DROPPED DEFLECTOR I POSITION) SPRINKLER SUPPORT CUP THREAD INTO i ASSEMBLY RETAINER SUPPORT CUP WITH THREAD UNTIL MOUNTING i i DIMPLES SURFACE IS FLUSH WITH CEILING C:) LO EJECTION SPRING SOLDER COVER TAB COVER PLATE PLATE RETAINER ASSEMBLY FIGURE 1 SERIES DS-C STANDARD COVERAGE DRY PENDENT CONCEALED SPRINKLER ASSEMBLY TFP515 Design Criteria The DS-C (TY3535) 3 mm Bulb Type, Dry Pendent Concealed Sprinklers are UL and C-UL Listed as quick response - standard spray sprinklers for use in accordance with the current NFPA standard, and the DS-C (TY3555), 5 mm Bulb Type, Dry Pendent Con- cealed Sprinklers are UL and C-UL Listed as standard response - stand- ard spray sprinklers for use in accord- ance with the current NFPA standard. The Series DS-C Dry Pendent Con- cealed Sprinklers are only listed when installed with the Series RFII Con- cealed Cover Plates having a factory applied painted or metallic finish. The Series DS-C must not be used in applications where the air pressure above the ceiling is greater than that below. Down drafts through the Sup- port Cup could delay sprinkler opera- tion in a fire situation. The Series DS-C Dry Pendent Con- cealed Sprinkler is to be installed in the 1 inch NPT outlet or run of malleable or ductile iron threaded tee fittings that meet the dimensional requirements of ANSI B16.3 (Class 150) or cast iron threaded tee fittings that meet the di- mensional requirements of ANSI B16.4 (Class 125) with the end sprin- kler fitting on a branch line to be plugged as shown in Figure 2. When installing 1 inch NPT Series DS-C Dry Sprinklers on a dry pipe sprinkler system, only use the side out- let of maximum 2-1/2 inch size reduc- ing tee's. For wet pipe sprinkler systems, the Series DS-C Sprinklers may also be installed in the 1 inch NPT outlet of a Central Figure 730 Mechanical Tee or the following Tyco Fire Products CPVC fittings: (P/N 80145) 1" x 1" NPT Fe- male Adapter or (P/N 80249) 1" x 1" x 1" NPT Sprinkler Head Adapter Tee. NOTE Do not install the Series DS-C into any other type fitting without first consult- ing the Technical Services Depart- ment. Failure to use the appropriate fitting may result in: failure of the sprin- kler to properly operate due to forma- tion of ice over the inlet Plug or binding of the inlet Plug; or, insufficient en- gagement of the inlet pipe threads with consequent leakage. Branch, cross, and feed main piping connected to Dry Sprinklers and sub- ject to freezing temperatures must be pitched for drainage in accordance with the minimum requirements of the Page 3 of 6 r----i F--� SPRINKLER FITTING I I I I (REFER TO DESIGN I CRITERIA SECTION) I i t I I I I I I I I I 1 1 FACE OF I L _ _ J SPRINKLER L _ _ J FITTING ORDER LENGTHS: 5" (127,0 mm) to 48" (1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS 3/16" I I SPRINKLER SUPPORT CUP ASSEMBLY, 2-1/2" DIA. (63,5 mm) &TrT (4,8 mm) 1 v 1 3/16" to 11/16" FACTORY DEFLECTOR COVER PLATE (4,8 to 17,5 mm) PRESET GAP IN DROPPED RETAINER REFERENCE 3/32" (2,4 mm) POSITION ASSEMBLY 3-1/4" DIA. (82,6 mm) FIGURE 2 SERIES DS-C STANDARD COVERAGE DRY PENDENT CONCEALED SPRINKLER INSTALLATION DIMENSIONS National Fire Protection Association for dry pipe sprinkler systems. When Dry Sprinklers are to be used in wet pipe sprinkler systems protecting areas subject to freezing temperatures (e.g., sprinkler drops into freezers), consideration must be given to the ap- propriate length of the sprinkler that will prevent freezing of the water in the connecting pipes due to conduction. When the temperature surrounding the wet pipe sprinkler system is main- tained at a minimum temperature of 40°F/4°C, the following are the mini- mum recommended lengths between the face of the sprinkler fitting and the outside surface of the protected area (i.e., length exposed to minimum am- bient of 40oF/4oC): • 12 inches (300 mm) when the tem- perature within the protected area is-20oF/-29°C • 18 inches (450 mm) when the tem- perature within the protected area is-40°F/-40°C • 24 inches (600 mm) when the tem- perature within the protected area is-60°F/-51 °C For protected area temperatures be- tween those given above, the minimum recommended length from the face of the fitting to the outside of the pro- tected area may be determined by in- terpolating between the indicated val- ues. NOTE When Dry Sprinklers penetrate a ceil- ing or wall into an area subject to freez- ing, the clearance space around the Sprinkler Casing must be completely sealed in order to prevent the leakage of moist air into the freezing area which might result in the formation of condensate around the Frame, Deflec- tor, Bulb Seat, or Bulb. Failure to pre- vent the formation of condensate could result in the build-up of ice around the releasing components. This could re- sult in inadvertent operation of the sprinkler or impaired operation due to reduced thermal sensitivity. Page 4 of 6 FRAME ARM TTRTT SUPPORT CUP 7/8" (23 mm) SQUARE ALIGN J ARROWS WITH FRAME ARMS al � r ACCEPTS 1/2" SOCKET DRIVE FIGURE 3 RFII SPRINKLER WRENCH CLEARANCE HOLE FIGURE 4 DISPOSABLE PROTECTIVE CAP Installation The Series DS-C Dry Pendent Con- cealed Sprinklers must be installed in accordance with the following instruc- tions: NOTES The Series DS-C must only be in- stalled in fittings that meet the requlre- ments of the Design Criteria section, Refer to the Design Criteria section for other important requirements regard- ing piping design and sealing of the clearance space around the Sprinkler Casing. Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1116 inch (1,6 mm). A leak tight 1 inch NPT sprinkler joint should be obtained with a torque of20 to 30 ft.lbs. (26,8 to 40,2 Nm). Higher levels of torque may distort the sprin- kler inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in the Sprinkler Assembly by under- or over -tightening TFP515 the Sprinkler/Support Cup Assembly, Readjust the position of the sprinkler fitting to suit. Step 1. The sprinkler must only be installed in the pendent position and with the centerline of the sprinkler per- pendicular to the mounting surface. Step 2. With pipe thread sealant ap- plied to the inlet threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Wrench tighten the sprinkler by wrenching on the Casing with a pipe wrench whenever the casing is readily accessible. Otherwise, use a RFII Sprinkler Wrench (Ref. Figure 3). The RFII Sprinkler Wrench is to be applied to the Sprinkler as shown in Figure 3. When using the RFII Sprinkler Wrench, temporarily remove the Pro- tective Cap. Replace the Protective Cap (Ref. Figure 4) by pushing it up- wards until it bottoms out against the Support Cup. The Protective Cap helps prevent damage to the Deflector and Arms during ceiling installation and/or during application of the finish coating of the ceiling. It may also be used to locate the center of the clear- ance hole by gently pushing the ceiling material up against the center point of the Protective Cap. NOTE As long as the Protective Cap remains in place, the system is considered to be "Out of Service". Step 4. After the ceiling has been com- pleted with the 2-1/2 inch (63,5 mm) diameter clearance hole and in prepa- ration for installing the Cover Plate As- sembly, remove and discard the Pro- tective Cap, and verify that the Deflector moves up and down freely. If the Sprinkler has been damaged and the Deflector does not move up and down freely, replace the entire Sprin- kler assembly. Do not attempt to mod- ify or repair a damaged sprinkler. Step 5. Screw on the Cover Plate/Re- tainer Assembly until the Retainer - Figure 2 contacts with the ceiling. Do not continue to screw on the Cover Plate/Retainer Assembly such that it lifts a ceiling panel out of its normal position. If the Cover Plate/Retainer Assembly cannot be engaged with the Support Cup or the Cover Plate/Re- tainer Assembly cannot be engaged sufficiently to contact the ceiling, the Sprinkler Fitting must be repositioned. TFP515 Care and Maintenance The Series DS-C Dry Pendent Con- cealed Sprinklers must be maintained and serviced in accordance with the following instructions: NOTES Absence of the Cover Plate Assembly may delay sprinkler operation in a fire situation. When properly installed, there is a nominal 3132 inch (2,4 mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 2. This air gap is necessary for proper opera- tion of the sprinkler. If the ceiling is to be repainted after the installation of the Sprinkler, care must be exercised to ensure that the new paint does NOT seal off any of the air gap. Factory painted Cover Plates MUST NOT be repainted. They should be re- placed, if necessary, by factory painted units. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection systems must be obtained from the proper authori- ties and all personnel who may be affected by this action must be notified. A Vent Hole is provided in the Bulb Seat (Ref. Figure 1) to indicate if the Dry Sprinkler is remaining dry. Evi- dence of leakage from the Vent Hole is an indication that there may be weepage past the Inlet seal and that the sprinkler needs to be removed for determining the cause of leakage (e.g. an improper installation or an ice plug). The fire protection system control valve must be closed and the system drained before removing the sprinkler. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be com- pletely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age - before, during, and after instal- lation. Sprinklers damaged by drop- ping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb (Ref. Installation Section). If a sprinkler must be removed, do not reinstall it or a replacement without reinstalling the Cover plate Assembly. If a Cover plate Assembly becomes dislodged during service, replace it im- mediately. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. it is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Page 5 of 6 Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' Lk ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. Page 6 of 6 P/N 60 - XXX - 1 - XXX MODEUSIN SPRINKLER 46 Quick Response TY3535 TEMPERATURE (3 mm Bulb) RATING 86 Standard Response TY3555 1 155°F/68°C (5 mm Bulb) 3 200°F/93°C NOTE (1). Dry Pendent Concealed Sprinklers are furnished based upon "Order Length" as measured per Figures 2, for each individual sprinkler where it is to be installed. After the measurement is taken, round it to the nearest 1/4 inch increment. TFP515 ORDER LENGTH (1) (EXAMPLES) 055 5.50" 082 8.25" 180 18.00" 187 18.75" 372 37.25" 480 48.00" TABLE A PART NUMBER SELECTION SERIES DS-C, STANDARD COVERAGE, DRY PENDENT CONCEALED SPRINKLERS WITH 1 INCH NPT CONNECTION (Use Prefix `I" for ISO 7-R1 Connection, e.g., 1-60-461-1-180) Ordering Procedure When placing an order, indicate the full product name. Contact your local dis- tributor for availability. Sprinkler Assembly: Specify: (SIN), (specify temperature rating), (specify Quick Response or Standard Response). Series DS-C Standard Coverage Dry Pendent Con- cealed Pendent Sprinkler with (specify inch) Order Length and (specify 1 inch NPT or ISO 7-R1) Connection, P/N (specify from Table A). NOTE Dry Pendent Concealed Sprinklers are furnished based upon Order Length as measured per Figure 2. After the measurement is taken, round it to the nearest 114 inch increment. Separately Ordered Cover Plate: Specify: (specify temperature rating) Series RFII Concealed Cover Plate with (specify finish), P/N (specify). 135°F/57°C(A) 165-Fr74°Clot Brass 56-792-1-135 56.792-1-165 Bright Brass 56-792-2-135 56-792.2-165 Chrome 56.792.9-135 56-792-9-165 Brushed Chrome 56-792-8-135 56-792.8-165 White 56.792.0-135 56-792-0-165 Bright White 56-792-4-135 56.792.4-165 Off White 56-792-5-135 56.792.5-165 White(RAL9010)' 56.792.3.135 56-792-3-165 Black 56-792-6-135 56-792-6-165 Custom 56.792-X-135 56-792-X-165 (A) For use with 155°F/68°C sprinklers. (B) For use with 200°F/93°C sprinklers. ' Eastern Hemisphere sales only. Sprinkler Wrench: Specify: RFII Sprinkler Wrench, P/N 56-000-1-075. TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 tqC0 Fire & Building Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Series DS-1 — 5.6 K-factor Dry Type Sprinklers Quick Response, Standard Coverage General Description The Series DS-1, 5.6 K-factor, Quick Response, Standard Coverage, Dry Type Sprinklers are decorative 3 mm glass bulb automatic sprinklers de- signed for the following typical uses: • where pendent sprinklers are re- quired on dry pipe systems that are exposed to freezing tempera- tures (e.g. sprinkler drops from un- heated portions of buildings) • where sprinklers and/or a portion of the connecting piping may be exposed to freezing temperatures (e.g. sprinkler drops from wet sys- tems into freezers, sprinkler sprigs from wet systems into un- heated attics, or horizontal piping extensions through a wall to pro- tect an unheated area of a build- ing) • where sprinklers are used on sys- tems that are seasonably drained to avoid freezing (e.g. vacation re- sort areas) WARNINGS The Series DS-1 Dry Type Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the IMPORTANT Always refer to Technical Data Sheet TFP700 for the 'INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 8 standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible formaintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. The Series DS-1 Dry Type Sprinklers must only be installed in fittings that meet the requirements of the Design Criteria section. Model/Sprinkler Identification Numbers TY3235 - (Pendent) TY3135 - (Upright) TY3335 - (Horizontal Sidewall) Technical Data Approvals UL and C-UL Listed. FM and NYC Approved. (Refer to Table A) Maximum Working Pressure 175 psi (12,1 bar) Inlet Thread Connection 1 inch NPT (Standard Order) ISO 7-R1 Discharge Coefficient K = 5.6 GPM/psis/2 (80,6 LPM/bars/2) Temperature Ratings Refer to Table A Finishes Sprinkler: Natural Brass, Chrome Plated, White Polyester Escutcheon: White Coated or Chrome Plated APRIL, 2004 Physical Characteristics Inlet . . . . . . . .. . . .. . Copper Plug . . . . . . . . . . Copper Yoke . . . . . . Stainless Steel Casing . . Galvanized Carbon Steel Insert . . . . . . . . . .. . . Bronze Bulb Seat . . . . . . Stainless Steel Bulb . . . . . . . . . . . . . . Glass Compression Screw . . . . . Bronze Deflector . . . . . . . . . . . Bronze Frame . . . . . . . . . . Bronze Guide Tube . . . . . . Stainless Steel Water Tube . . . . . . Stainless Steel Spring . . . . Stainless Steel Sealing Assembly . . . Beryllium Nickel w/Teflon* Escutcheon . . . . . Carbon Steel *Registered Trademark of DuPont Patents U.S.A. Patent No. 5,188,185 TFP510 Page 2of8 TFP510 SPRINKLER FINISH TY3235 Pendent TY3235 Pendent TY3335 Hor. Sidewall w/ Standard w/ Std. Escutcheon with top of Recessed Escutcheon (Ref. Fig. 5) Deflector -to -Ceiling (Ref. Fig. 3) w/ Deep Escutcheon distance of w/ Wide Flange (Ref. Fig. 6) 4 to 12 inches Recessed Escutcheon w/o Escutcheon (100 to 300 mm) (Ref. Fig. 4) (Ref. Fig. 7) w/ Std. Escutcheon (Ref. Fig. 9) TY3135 Upright w/ Deep Escutcheon w/o Escutcheon (Ref. Fig. 10) (Ref. Fig. 8) w/o Escutcheon (Ref. Fig. 11) Temperature Bulb Natural Chrome White Natural Chrome White Natural Chrome White Rating Color Code Brass Plated Polyester Brass Plated Polyester Brass Plated I Polyester 135'F/57'C Orange 1, 2, 3, 4 1, 2, 4 1, 2, 3, 4 1, 2, 4 1", 2', 3", 4 1", 2", 4 155'F/68°C Red 1, 2, 3, 4 1, 2, 4 1, 2, 3, 4 1, 2, 4 1", 2' 3", 4 1', 2', 4 175°F/791C Yellow 1, 2, 3, 4 1, 2, 4 1, 2, 3, 4 1, 2, 4 1", 2% 3'', 4 1', 2', 4 200'F/93'C Green 1, 2, 3, 4 1, 2, 4 1, 2, 3, 4 1, 2, 4 1", 2", 3"', 4 1", 2", 4 286'F/141'C Blue N/A 1, 2, 3, 4 1, 2, 4 1', 2', 3--, 4 1", 2', 4 Notes: 1. Listed by Underwriters Laboratories, Inc (Maximum order length of 48 inches). 2. Listed by Underwriters Laboratories for use in Canada. (Maximum order length of 48 inches). 3. Approved by Factory Mutual Research Corporation (Maximum order length of 48 inches) 4. Approved by the City of New York under MEA 352-01-E. Light and Ordinary Hazard Occupancies Only. Light Hazard Occupancies Only. N/A - Not Available. TABLE A SERIES DS-1, QUICK RESPONSE - STANDARD COVERAGE, DRY TYPE SPRINKLERS LABORATORY LISTINGS AND APPROVALS PLUG WITH INLET GASKETED SPRING PLATE SEAL YOKE SPRING CASING WATER TUBE INSERT GUIDE TUBE BULB S EAT FRAME 3 mm BULB VENT HOLE COMPRESSION DEFLECTOR SCREW FIGURE 1 SERIES DS-1 QUICK RESPONSE DRY TYPE SPRINKLER ASSEMBLY WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 2 W-TYPE 7 SPRINKLER WRENCH TFP510 SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) 1________r �i FACE OF ; SPRINKLER FITTING T \ ORDER LENGTHS: 3-1/2" to 48" (88,9 to 1219,2 mm) IN 1/4" (6,4 mm) 2.1/4" DIA. INCREMENTS (57 FACE Ot7D CEILIN 1-3/8" t 1/8"(34,9t 3,2 mm) FIGURE 3 TY3235 PENDENT w/ STANDARD RECESSED ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) r FACE OF SPRINKLER FITTING L ORDER LENGTHS: 3.1/2" DIA, 1/2" to 46" (88,9 mm) (12,7 to 1168,4 mm) 2-1/2" DIA. IN (63 5 mm)) INCREMENTS NTSTS 1 FACE OF CEILING 4-1/4" t 1/8" (108,0 t 3,2 mm) FIGURE 6 TY3235 PENDENT w/ DEEP ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING ORDER LENGTHS: 3-1/2" to 48" (88,9 to 1219,2 mm) IN 1/4" (6,4 mm) 3" DIA. INCREMENTS (76,2 mm) FACE OF CEILING 1-3/8" t 1/8" (34,9 t 3,2 mm) FIGURE 4 TY3235 PENDENT w/ WIDE FLANGE RECESSED ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF F_ SPRINKLER FITTING R........... ORDER LENGTHS: 5" to 48" (127,0 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS R MINIMUM 1-3/4" (44,5 mm) DEFLECTOR TO CEILING FIGURE 7 TY3235 PENDENT W/o ESCUTCHEON Page 3of8 SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING j -j ORDER LENGTHS: 2-1/2"to 48" 1-3/4" DIA. (63,5 to 1219,2 mm) (44,5 mm) IN 1/4" (6,4 mm) �{ INCREMENTS FACE OF CEILING 2-3/16" t 1/8" (55,6 t 3,2 mm) FIGURE 5 TY3235 PENDENT w/ STANDARD ESCUTCHEON TOP OF DEFLECTOR ORDER LENGTHS: 5" to 48" (127.0 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS FACE OF SPRINKLER FITTING SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FIGURE 8 TY3135 UPRIGHT w/o ESCUTCHEON Page 4 of 8 ORDER LENGTHS: 2-112" to 48' (63,5 to 1219,2 mm) IN 1/4' (6,4 mm) INCREMENTS 4" ± 1 /8" (101,6±3,2 mm) FACE OF FACE OF 1-3/4" DIA. SPRINKLER MOUNTING (44,5 mm) FITTING SURFACE 3" DIA. (76,2 mm) SPRINKLER FITTING -'-- (REFER TO DESIGN CENTERLINE 5/16" CRITERIA SECTION) OF WATERWAY (7,9 mm) FIGURE 9 TY3335 HORIZONTAL SIDEWALL W/STANDARD ESCUTCHEON ORDER LENGTHS: FACE OF 1/2' to 45-3/4" (12,7 to 1162,1 mm) MOUNTING IN 1/4" (6,4 mm) INCREMENTS SURFACE _ 4-13/16" ± 1/8" (122,2 ± 3,2 mm) FACE OF 2-1/2" DIA. F-7-1 SPRINKLER ,1i (63,5 mm) FITTING \\ 3-1/2" DIA. (88,9 mm) SPRINKLER FITTING -= (REFER TO DESIGN CENTERLINE 5/16' CRITERIA SECTION) OF WATERWAY (7,9 mm) FIGURE 10 TY3335 HORIZONTAL SIDEWALL W/ DEEP ESCUTCHEON ORDER LENGTHS: 5" to 48' (127,0 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS MINIMUM 2-1/4" (57.2 mm) FACE OF DEFLECTOR TO SPRINKLER MOUNTING FITTING SURFACE 3.5° 5/16" SPRINKLER FIT-TING'T (7,9 mm) (REFER TO DESIGN CENTERLINE CRITERIA SECTION) OF WATERWAY FIGURE 11 TY3335 HORIZONTAL SIDEWALL W/o ESCUTCHEON TFP510 Operation When the Series DS-1 is in service, water is prevented from entering the assembly by the Plug & Belleville Seal- ing Assembly (Ref. Figure 1) in the Inlet of the Sprinkler. The glass Bulb contains a fluid that expands when ex- posed to heat. When the rated tem- perature is reached, the fluid expands sufficiently to shatter the glass Bulb, and the Bulb Seat is released. The compressed Spring is then able to ex- pand and push the Water Tube as well as the Guide Tube outward. This action simultaneously pulls inward on the Yoke, withdrawing the Plug & Belleville Seal from the Inlet allowing the sprin- kler to activate and flow water. Design Criteria The Series DS-1 Sprinklers are in- tended for use in fire sprinkler systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on NFPA 13 requirements). The Series DS-1 Dry Type Sprinkler is to be installed in the 1 inch NPT outlet or run of malleable or ductile iron threaded tee fittings that meet the di- mensional requirements of ANSI B16.3 (Class 150) or cast iron threaded tee fittings that meet the di- mensional requirements of ANSI B16.4 (Class 125) with the end sprin- kler fitting on a branch line to be plugged as shown in Figures 3 - 11. When installing 1 inch NPT Series DS-1 Dry Type Sprinklers on a dry pipe sprinkler system, only use the side outlet of maximum 2-1/2 inch size re- ducing tee's. For wet pipe sprinkler systems, the Series DS-1 Dry Type Sprinklers may also be installed in the 1 inch NPT outlet of a Central Figure 730 Me- chanical Tee or the following Tyco Fire Products CPVC fittings: (P/N 80145) 1" x 1" NPT Female Adapter or (P/N 80249) 1" x 1 " x 1" NPT Sprinkler Head Adapter Tee. NOTE Do not install the Series DS-1 into any other type fitting without first consult- ing the Technical Services Depart- ment. Failure to use the appropriate fitting may result in: failure of the sprin- kler to properly operate due to forma- tion of ice over the inlet Plug or binding of the inlet Plug; or, insufficient en- TFP510 gagement of the inlet pipe threads with consequent leakage. Branch, cross, and feedmain piping connected to Dry Sprinklers and sub- ject to freezing temperatures must be pitched for drainage in accordance with the minimum requirements of the National Fire Protection Association for dry pipe sprinkler systems. When Dry Sprinklers are to be used in wet pipe sprinkler systems protecting areas subject to freezing temperatures (e.g., sprinkler drops into freezers), consideration must be given to the ap- propriate length of the sprinkler that will prevent freezing of the water in the connecting pipes due to conduction. When the temperature surrounding the wet pipe sprinkler system is main- tained at a minimum temperature of 40oF/4'C, the following are the mini- mum recommended lengths between the face of the sprinkler fitting and the outside surface of the protected area (i.e., length exposed to minimum am- bient of 401F/41C): • 12 inches (300 mm) when the tem- perature within the protected area is-20°F/-29°C • 18 inches (450 mm) when the tem- perature within the protected area is-40°F/-40°C • 24 inches (600 mtn) when the tem- perature within the protected area is -60 ° F/-51 °C For protected area temperatures be- tween those given above, the minimum recommended length from the face of the fitting to the outside of the pro- tected area may be determined by in- terpolating between the indicated val- ues. NOTE When Dry Sprinklers penetrate a ceil- ing or wall into an area subject to freez- ing, the clearance space around the Sprinkler Casing must be completely sealed in order to prevent the leakage of moist air into the freezing area which might result in the formation of condensate around the Frame, Deflec- tor, Bulb Seat, or Bulb. Failure to pre- vent the formation of condensate could result in the build-up of ice around the releasing components. This could re- sult an inadvertent operation of the sprinkler or impaired operation due to reduced thermal sensitivity. Installation The Series DS-1 Dry Type Sprinklers must be installed in accordance with the following instructions: NOTES The Series DS-1 must only be installed in fittings that meet the requirements of the Design Criteria section. Refer to the Design Criteria section for other important requirements regard- ing piping design and sealing of the clearance space around the Sprinkler Casing. Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/57°C rating to 1/8 inch (3,2 mm) for the 286°F/141 °C rating. A leak tight 1 inch NPT sprinkler joint should be obtained with a torque of20 to 30 ft.lbs. (26,8 to 40,2 Nm). Higher levels of torque may distort the sprin- kler inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in an Escutcheon Plate by under or over -tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit. Step 1. Pendent sprinklers must be installed only in the pendent position, and upright sprinklers must be in- stalled only in the upright position. The deflector of a pendent or upright sprin- kler is to be parallel to the ceiling. Horizontal sidewall sprinklers are to be installed in the horizontal position with their centerline of waterway perpen- dicular to the back wall and parallel to the ceiling. The word "TOP" on the De- flector is to face towards the ceiling. Step 2. With pipe thread sealant ap- plied to the inlet threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Wrench tighten the sprinkler by wrenching on the Casing with a pipe wrench whenever the casing is readily accessible. Otherwise, use a W-Type 7 Sprinkler Wrench (Ref. Figure 2). The wrench recess of the W-Type 7 is to be applied to the sprinkler wrench flats (Ref. Figure 2). Step 4. After the ceiling/wall has been installed/finished, slide on the outer piece of the Escutcheon until it comes in contact with the ceiling/wall. Do not lift the ceiling panel out of its normal position. In the case of the outer piece of the Page 5 of 8 Deep Escutcheon, hold the outer piece in contact with the mounting sur- face (ceiling), and then rotate the inner piece approximately 1/4 turn with re- spect to the outer piece, to hold the Deep Escutcheon firmly together. Care and Maintenance The Series DS-1 Dry Type Sprinklers must be maintained and serviced in accordance with the following instruc- tions: NOTES Absence of the outer piece of an es- cutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection systems must be obtained from the proper authorities and all personnel who may be affected by this action must be no- tified. A Vent Hole is provided in the Bulb Seat (Ref. Figure 1) to indicate if the Dry Sprinkler is remaining dry. Evi- dence of leakage from the Vent Hole is an indication that there may be weepage past the Inlet seal and that the sprinkler needs to be removed for determining the cause of leakage (e.g. an improper installation oran ice plug), The fire protection system control valve must be closed and the system drained before removing the sprinkler. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be com- pletely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age - before, during, and after instal- lation. Sprinklers damaged by drop- ping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb (Ref. Installation Section). The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- Page 6 of S ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS h9I H7�IJI�I�Iji � ' � i • r : 1::::► ': •: UT • - i .6 Ordering Procedure Contact your local distributor for avail- ability, and please specify the follow- ing: 1. Sprinkler. • Model/SIN. • Quick Response, Standard Cover- age, Dry Type Sprinkler • Deflector Style. • 5.6 K-factor. • Order Length. Dry Type Sprinklers are furnished based upon Order Length as measured per Figure 3 through 11, as applicable. After the meas- urement is taken, round it to the nearest 114 inch increment. • Inlet Connection (1 Inch NPT or ISO 7-R1). • Temperature Rating. • Sprinkler Finish. • Escutcheon Style and Finish, as applicable. • Part Number from Table B. (Part numbers are for 1 inch NPT stand- ard order sprinklers. Orders for all other sprinkler assemblies must be accompanied by a complete description.) 2. W-Type 7 Sprinkler Wrench. Refer to the Price List for complete listing of Part Numbers. TF510 TFP510 P/N 60 - XXX - X - XXX SPRINKLER ESCUTCHEON MODEUSIN FINISH FINISH (2) 36 Pendent w/ Standard TY3235 Escutcheon (V NPT) (Fig. 5) 33 Pendent w/ Deep TY3235 Escutcheon (V NPT) (Fig. 6) 37 Pendent w/ Std. Recessed TY3235 Escutcheon (V NPT) (Fig. 3) 32 Pendent w/o Escutcheon TY3235 Escutcheon (1" NPT) 1 (Fig. 7) 34 Sidewall w/ Standard TY3335 Escutcheon (V NPT) (Fig. 9) 43 Sidewall w/ Deep TY3335 Escutcheon (1" NPT) (Fig. 10) 44 Sidewall w/o TY3335 Escutcheon (1" NPT) (Fig. 11) 36 1 Upright w/o Escutcheon TY3135 (1" NPT) (Fig.8) 1 NATURAL BRASS WHITE 4 WHITE POLYESTER WHITE 9 CHROME PLATED CHROME PLATED 0 CHROME PLATED WHITE 3 WHITE (RAL9010)- WHITE (RAL9010)- TEMPERATURE RATING (3) 0 135 F/57C 1 155F/68C 2 175F/79C 3 200F/93C 4 286F/141C NOTES Page 7 of 8 ORDER LENGTH (1) (EXAMPLES) 055 5.50" 082 8.251. 180 18.001, 167 18.75" 372 37.25" 480 48,00" (1). Dry Type Sprinklers are furnished based upon "Order Length" as measured per Figures 3 through 11, as applicable, and for each individual sprinkler where it is to be installed. After the meas- urement is taken, round it to the nearest 1/4 inch increment. (2). Escutcheon Finish applies to sprinklers provided with escutcheons. (3). The 286F/141 C temperature rating applies to non -recessed sprinkler assemblies. Eastern Hemisphere sales only TABLE B PART NUMBER SELECTION SERIES DS-1, QUICK RESPONSE, STANDARD COVERAGE, DRY TYPE SPRINKLERS (Use Prefix `9" for ISO 7-R1 Connection, e.g., 1-60-361-1-180) Page 8 of 8 This page intentionally left blank by the manufacturer who apparently has little regard for all the paper it wastes and the energy and trees required for its printing. TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 TF510 SHILO AUTOMATIC SPRINKLERS, Inc. I� QUALITY FIRE PROTECTION 1224 ELEVENTH AVE NORTH NAMPA, IDAHO 83687 SHOP DRAWINGS Lillie Scales Fire Protection Design Email: design@shilosprinkler.com Phone (208) 442-0007 • (208) 466-0006 • Fax (208) 466-7890 • E-MAIL design@shilosprinkler.com