Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SMOKE DETECTORS - 22-00730 - 7N Apartments - Bldg 4 - Fire Alarm
DF-52521:B1 • 4/13/2012 — Page 1 of 2 i3 Series Photoelectric Smoke Detectors Conventional Initiating Devices DF-52521:B1 • F-505 General System Sensor’s i³™ Series photoelectric and photoelectric/ thermal smoke detectors represent a significant advancement in conventional detection, incorporating three key features: installation ease, intelligence, and instant inspection. Installation ease. The i³ Series redefines installation ease with its plug-in design. This allows an installer to pre-wire the bases included with the heads. The large wire-entry port and in-line terminals provide ample room for neatly routing the wiring inside the base. The base accommodates a variety of backbox mounting methods, as well as direct mounting with drywall anchors. To complete the installation, i³ Series heads plug into the base with a simple Stop-Drop ’N Lock™ action. Intelligence. i³ Series detectors offer a number of intelligent features to simplify testing and maintenance. Drift compensa- tion and smoothing algorithms, to minimize nuisance alarms, are standard in the i³ Series. When connected to the 2W-MOD loop test/maintenance module, two-wire i³ detectors are capa- ble of generating a remote maintenance signal when they need cleaning. This signal is indicated by LEDs located at the module and at the panel. To read the sensitivity of i³ detectors, the SENS-RDR is a wireless device that displays sensitivity in terms of percent-per-foot obscuration. Instant inspection. The i³ Series provides wide-angle red and green LED indicators for instant inspection of detector condi- tion. The LEDs indicate: normal standby, out-of-sensitivity, alarm, or freeze trouble conditions. The “EZ Walk” loop test feature is available on two-wire i³ Series detectors when con- nected to the 2W-MOD loop test/maintenance module. The “EZ Walk” feature verifies the initiating loop wiring by providing LED status indication at each detector. Features • Plug-in detector line — mounting base included. • Large wire-entry port. • In-line terminals with SEMS screws. • Mounts to octagonal and single-gang backboxes, 4" (101.6 mm) square backboxes, or directly to ceiling. • Stop-Drop ’N Lock attachment to base. • Removable detector cover and chamber for easy cleaning. • Built-in remote maintenance signaling. • Drift compensation and smoothing algorithms. • Simplified sensitivity measurement. • Wide-angle, dual-color LED indication. • Loop testing via “EZ Walk” feature. • Built-in test switch. Specifications PHYSICAL SPECIFICATIONS Operating Temperature Range: For models 2W-B and 4W-B: 32°F to 120°F (0°C to 49°C); for thermal models 2WT-B and 4WT-B: 32°F to 100°F (0°C to 37.8°C). Operating Humidity Range: 0% – 95% RH, non-condensing. Thermal Sensor: 135°F (57.2°C) fixed (models 2WT-B, 4WT-B). Freeze Trouble: 41°F (5°C) (models 2WT-B and 4WT-B). Sensitivity: 2.5%/foot (0.762%/meter) nominal. Input Terminals: Utilize 14 to 22 AWG wire. Dimensions (including base): 5.3" (134.62 mm) diameter, 2.0" inches (50.8 mm) high. Weight: 6.3 oz. (178.6 grams). Mounting Options: 3.5" (88.9 mm) octagonal backbox; 4" (101.6 mm) octagonal backbox; single-gang backbox; 4" (101.6 mm) square backbox with a plaster ring; or direct mount to ceiling. ELECTRICAL SPECIFICATIONS Operating Voltage: 12/24 V non-polarized nominal; 8.5 V minimum; 35 V maximum. Maximum Alarm Current” For two-wire models: 130 mA lim- ited by control panel; For four-wire models: 20 mA @ 12 V, 23 mA @ 24 V. Alarm Contact Ratings: For four-wire models: 0.5 A @ 30 VAC/VDC; not applicable for two-wire models. LED Modes Green LED Red LED Power Up Blink every 10 sec- onds Blink every 10 sec- onds Normal (Standby)Blink every 5 sec- onds OFF Out of Sensitivity OFF Blink every 5 sec- onds Freeze Trouble OFF Blink every 10 sec- onds Alarm OFF Solid ON Power Up Sequence for LED Indication Condition Duration Initial LED Status Indication 80 Seconds 68 8 5 p h o 1 . j p g Page 2 of 2 — DF-52521:B1 • 4/13/2012 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire•Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com FireLite® Alarms® is a registered trademark and i³™ and Stop-Drop ‘N Lock™ are trademarks of Honeywell International Inc. ©2012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. Made in the U.S. A. Architectural/Engineering Specifications Smoke detector shall be a System Sensor i³ Series model number ________, Listed to Underwriters Laboratories UL 268 Fire Protection Signaling Systems. The detector shall be a photoelectric type (models 2W-B, 4W-B) or a combination pho- toelectric/thermal (models 2WT-B, 4WT-B) with thermal sensor rated at 135°F (57.2°C). The detector shall include a mounting base for mounting to 3.5" (88.9 mm) and 4" (101.6 mm) octag- onal, single-gang, and 4" (101.6 mm) square backboxes with a plaster ring, or directly mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws. The detector shall allow pre-wiring of the base and the head shall be a plug-in type. The detector shall have a nominal sensitivity of 2.5%/foot (0.762%/meter) as measured in the UL smoke box. The detector shall be capable of auto- matically adjusting its sensitivity by means of drift compensa- tion and smoothing algorithms. The detector shall provide dual-color LED indication which blinks to indicate power-up, normal standby, out-of-sensitivity, alarm, and freeze trouble (models 2WT-B, 4WT-B) conditions. When used in conjunction with the 2W-MOD module, two-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel, and shall provide a loop testing capa- bility to verify the circuit without testing each detector individu- ally. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. •UL/ULC Listed: S911 • FM Approved •CSFM: 7272-1653:152 •MEA: 290-01-E •Maryland State Fire Marshal: Permit # 2093 Product Line Information 2W-B: Two-wire photoelectric smoke detector. C2W-BA: Same as 2W-B, ULC listing. 2WT-B: Two-wire photoelectric smoke detector with 135°F (57.2°C) fixed thermal sensor. C2WT-BA: Same as 2WT-B, ULC listing. 4W-B: Four-wire photoelectric smoke detector. C4W-BA: Same as 4W-B, ULC listing. 4WT-B: Four-wire photoelectric smoke detector with 135°F (57.2°C) fixed thermal sensor. C4WT-BA: Same as 4WT-B, ULC listing. ACCESSORIES: 2W-MOD2: Two-wire loop test/maintenance module. SENS-RDR: Sensitivity reader. A77-AB2: Retrofit adapter bracket, 6.6” (167.7cm) diameter.