Loading...
HomeMy WebLinkAboutPLANS - 22-00725 - AT&T Cell Tower - Equipment UpgradeREVISIONS REV DATE DESCRIPTION 0 08/16/22 ISSUED FOR REVIEW 90% SITE #: IDL04328 SITE NAME: REXBURG STEINER ELEVATOR FA #: 10133809 164 WEST 1ST NORTH REXBURG, ID 83440 INT JG Smartlink LLC 1997 Annapolis Exch.Pkwy # 200 Annapolis, MD 21401 Tel: 410-263-LINK (5465) Fax: 410-263-5470 www.smartlinkllc.com 706308 1 09/21/22 ISSUED FOR FINAL JG TITLE SHEET DRIVING DIRECTIONS VICINITY MAP DO NOT SCALE DRAWINGS SITE PHOTO CONTRACTOR SHALL VERIFY ALL PLANS & EXISTING DIMENSIONS & CONDITIONS ON THE JOB SITE & SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. SITE INFORMATION APPLICABLE CODES BUILDING CODE 2018 IBC ELECTRICAL CODE 2017 NEC TIA-222-H CONTACT INFORMATION SCOPE OF WORK T-1 T-1 TITLE SHEET 1 C-1 C-2 EQUIPMENT PLAN GN-1 GENERAL NOTES DRAWING INDEX SHEET NO.DESCRIPTION REVTOWER OWNER:AT&T MOBILITY SITE NUMBER-NAME: IDL04328-REXBURG STEINER ELEVATOR SITE ADDRESS:164 WEST 1ST NORTH REXBURG, ID 83440 COUNTY:MADISON LATITUDE: 43.829215 (43° 49' 45.17509" N) LONGITUDE:-111.788153 (111° 47' 17.35111" W) GROUND ELEVATION: 4868' AMSL OCCUPANCY TYPE: UNMANNED ZONING JURISDICTION: MADISON COUNTY ZONING CODE:LIGHT COMMERCIAL PARCEL NUMBER:RPRRXB10244220 POWER PROVIDER: ROCKY MOUNTAIN POWER TELCO PROVIDER:CENTURYLINK HEADING NORTH ON US-20 TOWARD REXBURG, TAKE EXIT 333. TAKE THE ID-33 E RAMP TO SALMON/REXBURG.TURN RIGHT AT ID-33 E/W MAIN ST. GO 1 MI. TURN LEFT AT N 2ND WEST. GO 0.1 MI. TURN RIGHT AT W 1ST NORTH ST. GO 200FT. SITE WILL BE ON THE LEFT 120'-0" MONOPOLE 5G NR 1SR CBAND, CBAND_DoD at&t IDL04328 REXBURG STEINER ELEVATOR FA#: 10133809 PTN#: 3771A153Z3/3771A1542J PACE ID: MRUTH053859/MRUTH053858 C-3 TOWER ELEVATIONS C-4 ANTENNA PLANS C-5 RF WARNING & EQUIPMENT DETAILS SITE PLAN C-6 EQUIPMENT DETAILS 1 1 1 1 1 1 1 E-1 ELECTRICAL DIAGRAM 1 RFDS VERSION : DATE UPDATED:2.00 G-1 GROUNDING DETAILS 1 7/25/2022 EQUIPMENT LEVEL ANTENNA LEVEL ·INSTALL PROPOSED 1xAMIA / 3xABIO / 1xASIL ·INSTALL (1) PROPOSED VERTIV RECTIFIER ·INSTALL (1) PROPOSED DC12-48-60-RM ·REMOVE (3) EXISTING SBNHH-1D65C ANTENNAS ·REMOVE (3) EXISTING LGP-18-601 TMAS ·INSTALL (3) PROPOSED AEQU ANTENNAS ·INSTALL (3) PROPOSED AEQK ANTENNAS ·INSTALL (1) #6 DC TRUNK (1) 24 PAIR FIBER TRUNK ·INSTALL (1) DC9-48-60-24-8C-EV - DOME NOT TO SCALE SITE A&E SERVICES: TRILEAF CORPORATION 1821 WALDEN OFFICE SQUARE SUITE 500 SCHAUMBURG, IL 60173 CONTACT: HILDA ALLAWIRDI PHONE: (630) 227-0202, EXT. 537 EMAIL: h.allawirdi@trileaf.com SITE ACQUISITION SERVICES: SMARTLINK GROUP, LLC 1997 ANNAPOLIS EXCH. PWKY SUITE 200 ANNAPOLIS, MD 21401 CONTACT: TAMARA SHIVELEY PHONE: (801) 230-4877 REVISIONS REV DATE DESCRIPTION 0 08/16/22 ISSUED FOR REVIEW 90% SITE #: IDL04328 SITE NAME: REXBURG STEINER ELEVATOR FA #: 10133809 164 WEST 1ST NORTH REXBURG, ID 83440 INT JG Smartlink LLC 1997 Annapolis Exch.Pkwy # 200 Annapolis, MD 21401 Tel: 410-263-LINK (5465) Fax: 410-263-5470 www.smartlinkllc.com 706308 1 09/21/22 ISSUED FOR FINAL JG GENERAL NOTES GN-1 GENERAL CONSTRUCTION NOTES: 1. FOR THE PURPOSE OF CONSTRUCTION DRAWINGS, THE FOLLOWING DEFINITIONS SHALL APPLY: GENERAL CONTRACTOR: TBD SUBCONTRACTOR: TBD 2. ALL SITE WORK SHALL BE COMPLETED AS INDICATED ON THE DRAWINGS AND AT&T PROJECT SPECIFICATIONS. 3. GENERAL CONTRACTOR AND SUBCONTRACTOR SHALL VISIT THE SITE AND SHALL FAMILIARIZE HIMSELF WITH ALL CONDITIONS AFFECTING THE PROPOSED WORK AND SHALL MAKE PROVISIONS. GENERAL CONTRACTOR AND SUBCONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING HIMSELF WITH ALL CONTRACT DOCUMENTS, FIELD CONDITIONS, DIMENSIONS, AND CONFIRMING THAT THE WORK MAY BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER PRIOR TO THE COMMENCEMENT OF WORK. 4. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. GENERAL CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES REGULATIONS, AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF WORK. 5. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES, AND APPLICABLE REGULATIONS. 6. UNLESS OTHER WISE, THE WORK SHALL INCLUDE FURNISHING, MATERIALS, EQUIPMENT, APPURTENANCES, AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 7. PLANS ARE NOT TO BE SCALED. THESE PLANS ARE INTENDED TO BE A DIAGRAMMATIC OUTLINE ONLY UNLESS OTHERWISE NOTED. DIMENSIONS SHOWN ARE TO BE FINISH SURFACES UNLESS OTHERWISE NOTED. SPACING BETWEEN EQUIPMENT IS THE MINIMUM REQUIRED CLEARANCE. THEREFORE, IT IS CRITICAL TO FIELD VERIFY DIMENSIONS, SHOULD THERE BE ANY QUESTIONS REGARDING THE CONTRACT DOCUMENTS, THE SUBCONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING A CLARIFICATION FROM THE ARCHITECT/ENGINEER PRIOR TO PROCEEDING WITH THE WORK. DETAILS ARE INTENDED TO SHOW DESIGN INTENT. MODIFICATIONS MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF WORK AND PREPARED BY THE ARCHITECT/ENGINEERPRIOR TO PROCEEDING WITH WORK. 8. THE SUBCONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. 9. IF THE SPECIFIED EQUIPMENT CANNOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE SUBCONTRACTOR SHALL PROPOSE AN ALTERNATIVE SPACE FOR APPROVAL BY THE ARCHITECT/ENGINEER PRIOR TO PROCEEDING. 10. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF WORK AREA, ADJACENT AREAS AND BUILDING OCCUPANTS THAT ARE LIKELY TO BE AFFECTED BY THE WORK UNDER THIS CONTRACT. WORK SHALL CONFORM TO ALL OSHA REQUIREMENTS AND LOCAL JURISDICTION. 11. GENERAL CONTRACTOR SHALL COORDINATE WORK AND SCHEDULE WORK ACTIVITIES WITH OTHER DISCIPLES. 12. ERECTION SHALL BE DONE IN A WORK MANLIKE MANNER BY COMPETENT EXPERIENCED PRACTICE. ALL MEMBERS SHALL BE LAID PLUMB AND TRUE AS INDICATED ON THE DRAWINGS. 13. SEAL PENETRATIONS THROUGH FIRE RATED AREAS WITH UL LISTED MATERIALS APPROVED BY LOCAL JURISDICTION. SUB CONTRACTOR SHALL KEEP AREA CLEAN, HAZARD FREE, AND DISPOSE OF ALL DEBRIS. 14. WORK PREVIOUSLY COMPLETED IS REPRESENTED BY LIGHT SHADED LINES AND NOTES. THE SCOPE OF WORK FOR THIS PROJECT IS REPRESENTED BY DARK SHADED LINES AND NOTES. SUB CONTRACTOR SHALL NOTIFY THE GENERAL CONTRACTOR OF ANY EXISTING CONDITIONS THAT DEVIATE FROM THE DRAWING PRIOR TO THE BEGINNING CONSTRUCTION. 15. SUBCONTRACTOR SHALL PROVIDE WRITTEN NOTICE TO THE CONSTRUCTION MANAGER 48 HOURS PRIOR TO THE COMMENCEMENT OF WORK. 16. THE SUBCONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT SUBCONTRACTORS EXPENSE TO THE SATISFACTION OF THE OWNER. 17. THE SUBCONTRACTOR SHALL CONTACT UTILITY LOCATING SERVICES PRIOR TO THE START OF CONSTRUCTION. 18. GENERAL CONTRACTOR SHALL COORDINATE AND MAINTAIN ACCESS FOR ALL TRADES AND SUBCONTRACTORS TO THE SITE AND/OR BUILDING. 19. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SECURITY OF THE SITE FOR THE DURATION OF CONSTRUCTION UNTIL JOB COMPLETION. 20. THE GENERAL CONTRACTOR SHALL MAINTAIN GOOD CONDITION ONE COMPLETE SET OF PLANS WITH ALL REVISION, ADDENDA, AND CHANGES ORDERS ON THE PREMISES AT ALL TIMES. 21. CONTRACTOR SHALL MINIMIZE DISTURBANCE TO THE EXISTING SITE DURING CONSTRUCTION, EROSION CONTROL MEASURES, IF REQUIRED DURING CONSTRUCTION, SHALL BE IN CONFORMANCE WITH THE FEDERAL AND LOCAL JURISDICTION FOR EROSION AND SEDIMENT CONTROL. 22. THE SUBGRADE SHALL BE BROUGHT TO A SMOOTH GRADE AND COMPACTED TO 95 PERCENT STANCE PROCTOR DENSITY UNDER PAVEMENT AND STRUCTURES AND 80 PERCENT STANDARD PROCTOR DENSITY IN OPEN SPACE, ALL TRENCHES IN PUBLIC RIGHT OF WAY SHALL BE BACKFILLED WITH FLOWABLE FILL OR OTHER MATERIAL, PRE-APPROVED BY THE LOCAL JURISDICTION. 23. ALL NECESSARY RUBBISH, STUMPS, DEBRIS, STICKS, STONES AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF IN A LAWFUL MANNER. ELECTRICAL GROUNDING SPECIFICATIONS: 1. GROUNDING SHALL COMPLY WITH ARTICLE 250 OF THE NATIONAL ELECTRICAL CODE CURRENTLY IN EFFECT FOR THE AUTHORITY HAVING JURISDICTION. 2. ALL GROUNDING DEVICE SHALL BE U.L. LISTED FOR THEIR INTENDED USE. 3. GROUND WIRES SHALL BE TINNED #2 AWG BARE SOLID COPPER UNLESS OTHERWISE NOTED. 4. CONNECTIONS OF ALL GROUND WIRES TO THE GROUND RING SHALL BE EXOTHERMIC (CAD-WELDED), UNLESS OTHERWISE NOTED AND SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND AT&T WIRELESS BROADBAND STANDARDS. 5. GROUNDING CONDUCTORS SHALL BE ROUTED ALONG THE SHORTEST AND STRAIGHTEST PATH POSSIBLE WHEN REQUIRED. GROUND LEADS SHALL BE BENT TO A MINIMUM OF 8' RADIUS. 6. WHERE GROUND WIRES ARE ROUTED FROM ANY CONNECTION ABOVE GRADE TO THE GROUND RING, INSTALL WIRE IN 314' HEAVY WALL LIQUID TIGHT FLEXIBLE CONDUIT FROM CONNECTION POINT TO 5' BELOW GRADE AND SEAL THE TOP WITH SILICONE SEALANT. 7. ALL GROUND BARS SHALL BE TINNED COPPER, SECTOR BARS 2", COLLECTOR AND MGB BARS 4", OF SUFFICIENT LENGTH TO ACCOMMODATE ALL REQUIRED CONNECTIONS WITHOUT DOUBLING LIGS, AND EACH INSTALLED WITH ISOLATORS. WHEN CONNECTING GROUND BARS (WITHIN 10 FEET OF GRADE) DIRECTLY TO THE GROUND RING, 2 EA. #2 SOLID DOWNLEADS SHALL BE CAD-WELDED TO THE GROUNDING, 1 AT EACH OPPOSITE BOTTOM CORNER, AND EACH SHALL RUN IN 3/4" HEAVY WALL LIQUID TIGHT FLEXIBLE CONDUIT FROM GROUND BAR DOWN TO THE GROUND RING, WHEN CONNECTING SECTOR GROUND BARS, DAISY-CHAIN THE GROUND BARS AND RUN 1 EA. #2 AWG STRANDED COPPER WIRE WITH THWN INSULATION FROM THE MIDDLE GROUND BAR TO THE GROUND RING AND CAD-WELD TO THE RING. 8. WHEN ATTACHING STRANDED GROUND LEADS TO THE GROUND BARS, 2 HOLE COMPRESSION LUGS SHALL BE USED, PROTECT WITH WEATHERPROOF HEAT SHRINK, AND WITH A THIN COAT OF "KOP'R SHIELD' OR EQUIVALENT PROPERLY APPLIED AND ATTACHED ONLY WITH STAINLESS STEEL HARDWARE. 9. WHEN GROUNDING EQUIPMENT ENCLOSURES, PANELS, FRAMES, AND OTHER METAL APPARATUS, A #6 AV/G STRANDED COPPER WIRE WITH THWN INSULATlON SHALL BE ATTACHED UTILIZING A 2 HOLE COMPRESSION TYPE LUG, PROTECTED WITH WEATHERPROOF HEAT A CLEAN AND CORROSION FREE METALLIC SURFACE UTILIZING STAINLESS STEEL SELF-TAPPING SCREWS AS NOTED IN NOTE 10 BELOW. 10. PREPARE ALL BONDING SURFACES FOR GROUND CONNECTIONS BY REMOVING ANY AND ALL PAINT AND CORROSION TO SHINY METAL. CAD-WELDED CONNECTIONS TO NON-GOPPER SURFACES, APPLY ONE COAT OF ANY ANTI-OXIDIZING PAINT, "COLD GALV" OR EQUIVALENT. 11. GROUND RODS SHALL BE COPPER-CLAD STEEL 5/8"x10', SPACED NO LESS THAN 10' ON CENTER. 12. ALL GROUND SYSTEM CONDUCTORS AND CONDUITS SHALL BE SECURED UTILIZING ONLY NONMETALLIC, NON-CONDUCTIVE, UV RATED CLAMPS, BRACKET, AND OR SUPPORTS. 13. WHEN REQUIRED, THE CONTRACTOR SHALL ENGAGE THE SERVICES OF AN INDEPENDENT TESTING FIRM TO VERIFY, UTILIZING A MEGGER TEST, THAT THE RESISTANCE TO EARTH OF THE NEW GROUND SYSTEM IS EQUAL TO OR LESS THAN 5 (OHMS). A COPY OF THE COMPLETE TESTING REPORT SHALL BE PROVIDED TO THE AT&T REPRESENTATIVE. 14. ALL MATERIALS AND HARDWARE SHALL BE INSTALLED IN A WORKMAN-LIKE MANNER IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS, AND DEFINED IN NFPA-70. 15. ALL RRH GROUND WIRES SHALL BE #2 GREEN STRANDED. 16. ALL GROUND LUGS SHALL BE 2-HOLE LONG BARRELL. 17. OUTDOOR GROUNDS SHALL BE BLACK HEAT SHRINK W/O INSPECTION HOLES. 18. INDOOR GROUNDS SHALL BE CLEAR HEAT SHRINK W/ INSPECTION HOLES. ANTENNA PIPE MOUNTS: 1. PROPOSED OR REPLACEMENT ANTENNA PIPE MOUNTS SHALL BE 2-3/8" (O.D.)X10', SCH. 80 PIPE, UNLESS NOTED OTHERWISE. REVISIONS REV DATE DESCRIPTION 0 08/16/22 ISSUED FOR REVIEW 90% SITE #: IDL04328 SITE NAME: REXBURG STEINER ELEVATOR FA #: 10133809 164 WEST 1ST NORTH REXBURG, ID 83440 INT JG Smartlink LLC 1997 Annapolis Exch.Pkwy # 200 Annapolis, MD 21401 Tel: 410-263-LINK (5465) Fax: 410-263-5470 www.smartlinkllc.com 706308 1 09/21/22 ISSUED FOR FINAL JG SITE PLAN SITE PLAN 1 C-10SCALE: 1" = 10' (24x36) (OR) 1" = 20' (11x17) 5' 10'10' THE UTILITIES AS SHOWN ON THIS SET OF DRAWINGS WERE DEVELOPED FROM THE INFORMATION AVAILABLE. THE INFORMATION PROVIDED IS NOT IMPLIED NOR INTENDED TO BE A COMPLETE INVENTORY OF THE UTILITIES IN THIS AREA. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE LOCATION OF ALL UTILITIES (WHETHER SHOWN OR NOT) AND PROTECT SAID UTILITIES FROM ANY DAMAGE CAUSED BY CONTRACTOR'S ACTIVITIES. EXISTING AT&T EQUIPMENT (SEE SHEET C-2 FOR DETAILS)40'-0"± 20 ' - 0 " ± PROPOSED/EXISTING ANTENNAS AND RRH UNITS (SEE SHEET C-4 FOR DETAILS) NOTE: THESE DRAWINGS WERE PREPARED BASED ON EXISTING DRAWINGS AND INFORMATION PROVIDED BY OTHERS. ALL EXISTING CONDITIONS SHOULD BE FIELD VERIFIED PRIOR TO CONSTRUCTION. EXISTING BUILDING EXISTING BUILDING EXISTING BUILDING EXISTING BUILDING EXISTING GRAVEL AREA EXISTING GRAVEL AREAEXISTING ICE BRIDGE EXISTING CHAIN LINK FENCE EXISTING ACCESS GATE EXISTING MONOPOLE (SEE SHEET C-3 FOR DETAILS) EXISTING GENERATOR ON CONCRETE PAD EXISTING UTILITY H-FRAME 12'-7"± REVISIONS REV DATE DESCRIPTION 0 08/16/22 ISSUED FOR REVIEW 90% SITE #: IDL04328 SITE NAME: REXBURG STEINER ELEVATOR FA #: 10133809 164 WEST 1ST NORTH REXBURG, ID 83440 INT JG Smartlink LLC 1997 Annapolis Exch.Pkwy # 200 Annapolis, MD 21401 Tel: 410-263-LINK (5465) Fax: 410-263-5470 www.smartlinkllc.com 706308 1 09/21/22 ISSUED FOR FINAL JG C-2 EQUIPMENT PLAN 2EXISTING EQUIPMENT PLAN 0 6" 1'1'SCALE: 1" = 1'-0" (24x36) (OR) 1/2" = 1'-0" (11x17)NEW EQUIPMENT PLAN KEY NOTES: EXISTING 11'-5"x12'-0" AT&T EQUIPMENT SHELTER1 EXISTING HVAC UNIT2 3 EXISTING GPS ANTENNA4 5 EXISTING ACCESS DOOR6 EXISTING UMTS NODE B CABINET7 EXISTING DISCONNECT SWITCH 101' 2'2'SCALE: 1/2" = 1'-0" (24x36) (OR) 1/4" = 1'-0" (11x17) 3 2 2 9 7 8 12 1 6 5 11 10 EXISTING ICE BRIDGE 8 EXISTING LTE FIF RACK9 10 EXISTING TELCO BOARD11 EXISTING CABLE LADDER (ABOVE)12 EXISTING AC PANEL EXISTING -48vDC POWER PLANT 4 KEY NOTES: EXISTING 11'-5"x12'-0" AT&T EQUIPMENT SHELTER EXISTING HVAC UNIT EXISTING GPS ANTENNA EXISTING ACCESS DOOR EXISTING UMTS NODE B CABINET EXISTING DISCONNECT SWITCH 3 2 2 7 8 12 1 6 5 11 10 EXISTING ICE BRIDGE EXISTING LTE FIF RACK, INSTALL 1XAMIA / 3XABIO / 1XASIL EXISTING TELCO BOARD EXISTING CABLE LADDER (ABOVE) EXISTING AC PANEL EXISTING -48vDC POWER PLANT, INSTALL (1) PROPOSED RECTIFIER 4 EXISTING DC12-48-60-RM13 13 13 EXISTING DC12-48-60-RM13 1 2 3 4 5 6 7 8 9 10 11 12 14 INSTALL 1xAMIA / 3xABIO / 1xASIL TO EXISTING IN EXISTING LTE RACK INSTALL (1) PROPOSED RECTIFIER INSTALL (1) PROPOSED DC12-48-60-RM 2' - 1 1 " 0'-10" 1' - 1 1 " 1'-11" INSTALL (1) DC12-48-60-RM14 9 REVISIONS REV DATE DESCRIPTION 0 08/16/22 ISSUED FOR REVIEW 90% SITE #: IDL04328 SITE NAME: REXBURG STEINER ELEVATOR FA #: 10133809 164 WEST 1ST NORTH REXBURG, ID 83440 INT JG Smartlink LLC 1997 Annapolis Exch.Pkwy # 200 Annapolis, MD 21401 Tel: 410-263-LINK (5465) Fax: 410-263-5470 www.smartlinkllc.com 706308 1 09/21/22 ISSUED FOR FINAL JG C-3 TOWER ELEVATIONS 2PROPOSED ELEVATION1EXISTING ELEVATION SCALE: 3/16" = 1'-0" (24x36) (OR) 3/32" = 1'-0" (11x17) 0 3' 6'6'0 SCALE: 1" = 10' (24x36) (OR) 1" = 20' (11x17) 5' 10'10' EXISTING MONOPOLE EXISTING (3) RRH4X25-WCS-4R RRHS, (3) B12/14 320W AHLBA RRHS, (3) B25/66 320W AHFIB RRHS TO REMAIN (TYP. 1 EACH PER SECTOR) EXISTING (3) SBNHH-1D65C ANTENNAS TO BE REMOVED (TYP. 1 PER SECTOR) EXISTING (3) 80010992 ANTENNAS TO REMAIN (TYP. 1 PER SECTOR) EXISTING (3) RV4PX310R-V2 ANTENNAS TO REMAIN (TYP. 1 PER SECTOR) NOTE: STRUCTURAL ANALYSIS MUST BE PERFORMED BEFORE THE INSTALLATION OF NEW ANTENNAS, RRH UNITS, ETC. EXISTING AT&T EQUIPMENT SHELTER EXISTING ICE BRIDGE EXISTING CHAIN LINK FENCE COMPOUND EXISTING (4) #8 DC TRUNKS, (2) FIBER TRUNKS & (6) 1-5/8" COAX CABLES TO REMAIN AND UTILIZED EXISTING (3) LGP-18-6001 TMAS TO BE REMOVED (TYP. 1 PER SECTOR) EXISTING MONOPOLE EXISTING (3) RRH4X25-WCS-4R RRHS, (3) B12/14 320W AHLBA RRHS, (3) B25/66 320W AHFIB RRHS TO REMAIN (TYP. 1 EACH PER SECTOR) PROPOSED (1) DC9-48-60-24-8C-EV RAYCAP SQUID TO INSTALLED (SEE SHEET 4/C-5 FOR DETAILS) EXISTING (3) 80010992 ANTENNAS TO REMAIN (TYP. 1 PER SECTOR) EXISTING (3) RV4PX310R-V2 ANTENNAS TO REMAIN (TYP. 1 PER SECTOR) EXISTING AT&T EQUIPMENT SHELTER EXISTING ICE BRIDGE EXISTING CHAIN LINK FENCE COMPOUND EXISTING (4) #8 DC TRUNKS, (2) FIBER TRUNKS & (6) 1-5/8" COAX CABLES TO REMAIN AND UTILIZED INSTALL (3) AEQU DOD ANTENNA IN TOP LOCATION (1 PER SECTOR) INSTALL (3) AEQK C-BAND ANTENNAS IN BOTTOM LOCATION (1 PER SECTOR) SEE C-6/1, 2 &3 FOR DETAILS EXISTING (2) DC648-60-18-8C-EV RAYCAPS TO REMAIN PROPOSED (1) #6 DC TRUNK & (1) 24 PAIR FIBER TRUNK TO BE INSTALLED IN INNER DUCT EXISTING (2) DC648-60-18-8C-EV RAYCAPS TO REMAIN REVISIONS REV DATE DESCRIPTION 0 08/16/22 ISSUED FOR REVIEW 90% SITE #: IDL04328 SITE NAME: REXBURG STEINER ELEVATOR FA #: 10133809 164 WEST 1ST NORTH REXBURG, ID 83440 INT JG Smartlink LLC 1997 Annapolis Exch.Pkwy # 200 Annapolis, MD 21401 Tel: 410-263-LINK (5465) Fax: 410-263-5470 www.smartlinkllc.com 706308 1 09/21/22 ISSUED FOR FINAL JG C-4 NOTE TO CONTRACTOR: 1. ANTENNA CLEARANCE AND MOUNTING TO BE FIELD VERIFIED PRIOR TO CONSTRUCTION WITH FINAL ANTENNA SPECIFICATIONS MOUNTING HARDWARE AND RF DESIGN. ANTENNA PIPE MOUNT MODIFICATION MAY BE REQUIRED. 2. CONTRACTOR TO VERIFY FINAL ANTENNA CONFIGURATION FROM FINAL RFDS. 3. CONTRACTOR SHALL VERIFY A MINIMUM OF 4 FEET SEPARATION BETWEEN ALL ANTENNAS. 4. STRUCTURAL ANALYSIS MUST BE PERFORMED ON ALL ROOFTOPS, FLAGPOLES, LIGHT POLES, AND TOWER SITES BEFORE INSTALLATION OF NEW ANTENNAS, RRH UNITS, ETC. ANTENNA PLANS 2 1 PROPOSED ANTENNA PLAN EXISTING ANTENNA PLAN SCALE: NTS SCALE: NTS EXISTING ANTENNA AND TRANSMISSION CABLE REQUIREMENT RAD ANTENNA TYPE QTY LENGTH TYPE TRANSMISSION CABLEANTENNA AZIMUTHTECHNOLOGY SBNHH-1D65CA1 A2 GA M M A , 1 2 0 ' - 0 " B E T A , 1 2 0 ' - 0 " AL P H A , 1 2 0 ' - 0 " SECTOR CTR - 0° PROPOSED ANTENNA AND TRANSMISSION CABLE REQUIREMENT RAD ANTENNA TYPE QTY LENGTH TYPE TRANSMISSION CABLEANTENNA AZIMUTHTECHNOLOGY SECTOR CTR UMTS1900 B1 B2 C1 C2 A3 B3 C3 A4 B4 C4 - 120° - 240° PROPOSED (1) DC9-48-60-24-8C-EV RAYCAP SQUID TO INSTALLED (SEE 4/C-5 FOR DETAILS) RV4PX310R-V2 - 80010992 LTE WCS - LTE 700/1900AWS 0° 0° 120° 120° 240° 240° SBNHH-1D65C UMTS1900 RV4PX310R-V2 - 80010992 LTE WCS - LTE 700/1900AWS SBNHH-1D65C UMTS1900 RV4PX310R-V2 - 80010992 LTE WCS - LTE 700/1900AWS - -140'COAX 140'- --FIBER -140'FIBER 140'COAX 140'- -FIBER 140'FIBER 140'COAX 140'- -FIBER 140'FIBER - - - - - - - - AEQU+AEQK STACKEDA1 A2 BE T A , 1 2 0 ' & 1 2 1 ' AL P H A , 1 2 0 ' & 1 2 1 ' - 0°5G CBAND / DOD B1 B2 C1 C2 A3 B3 C3 A4 B4 C4 - 120° - 240° RV4PX310R-V2 - 80010992 LTE WCS - 0° 0° 120° 120° 240° 240° RV4PX310R-V2 - 80010992 LTE WCS - RV4PX310R-V2 - 80010992 LTE WCS - LTE 700/1900AWS 5G AWS - -140' 140'- --FIBER -140'FIBER 140' 140'- -FIBER 140'FIBER 140' 140'- -FIBER 140'FIBER - - - - - - - - GA M M A , 1 2 0 ' & 1 2 1 ' FIBER FIBER FIBER AEQU+AEQK STACKED 5G CBAND / DOD AEQU+AEQK STACKED 5G CBAND / DOD LTE 700/1900AWS 5G AWS LTE 700/1900AWS 5G AWS EXISTING (3) RRH4X25-WCS-4R RRHS, (3) B12/14 320W AHLBA RRHS, (3) B25/66 320W AHFIB RRHS TO REMAIN (TYP. 1 EACH PER SECTOR) EXISTING (3) SBNHH-1D65C ANTENNAS TO BE REMOVED (TYP. 1 PER SECTOR) EXISTING (3) 80010992 ANTENNAS TO REMAIN (TYP. 1 PER SECTOR) EXISTING (3) RV4PX310R-V2 ANTENNAS TO REMAIN (TYP. 1 PER SECTOR) EXISTING (3) LGP-18-6001 TMAS TO BE REMOVED (TYP. 1 PER SECTOR) EXISTING (2) DC648-60-18-8C-EV RAYCAPS TO REMAIN EXISTING ANTENNA PLATFORM MOUNT EXISTING MONOPOLE EXISTING (3) RRH4X25-WCS-4R RRHS, (3) B12/14 320W AHLBA RRHS, (3) B25/66 320W AHFIB RRHS TO REMAIN (TYP. 1 EACH PER SECTOR) INSTALL (3) AEQU DOD ANTENNA IN TOP LOCATION (1 PER SECTOR) AND INSTALL (3) AEQK C-BAND ANTENNAS IN BOTTOM LOCATION (1 PER SECTOR) SEE C-6/1, 2 &3 FOR DETAILS EXISTING (3) 80010992 ANTENNAS TO REMAIN (TYP. 1 PER SECTOR) EXISTING (3) RV4PX310R-V2 ANTENNAS TO REMAIN (TYP. 1 PER SECTOR) EXISTING (2) DC648-60-18-8C-EV RAYCAPS TO REMAIN EXISTING ANTENNA PLATFORM MOUNT EXISTING MONOPOLE A-3 A-4 LTE 700/ 1900/AWS A-2 LTE WCS A-1 UMTS 1900 C-1 UMTS 1900 C-2 LTE WCS C-3 C-4 LTE 700/ 1900/AWS B-1 UMTS 1900 B-2 LTE WCS B-3 B-4 LTE 700/ 1900/AWS A-3 A-4 LTE 700/ 1900/AWS/ 5G AWS A-2 LTE WCS A-1 5G CBAND / DOD C-1 5G CBAND / DOD C-2 LTE WCS C-3 C-4 LTE 700/ 1900/AWS/ 5G AWS B-1 5G CBAND / DOD B-2 LTE WCS B-3 B-4 LTE 700/ 1900/AWS/ 5G AWS REVISIONS REV DATE DESCRIPTION 0 08/16/22 ISSUED FOR REVIEW 90% SITE #: IDL04328 SITE NAME: REXBURG STEINER ELEVATOR FA #: 10133809 164 WEST 1ST NORTH REXBURG, ID 83440 INT JG Smartlink LLC 1997 Annapolis Exch.Pkwy # 200 Annapolis, MD 21401 Tel: 410-263-LINK (5465) Fax: 410-263-5470 www.smartlinkllc.com 706308 1 09/21/22 ISSUED FOR FINAL JG C-5 RF WARNING & EQUIPMENT DETAILS 1 3 2 RF WARNING SIGNAGE NOT USED 5 CAUTION AT&T Mobility WARNING Beyond this point: Radio frequency fields at this site exceed FCC rules for human exposure. Failure to obey posted signs and site guidelines for working in radio frequency AT&T MobilityRef: FCC 47 CFR 1.1307(b) environments could result in serious injury. Radio frequency fields beyond this point may exceed FCC general public exposure limit. Obey all posted signs and site guidelines for working in radio frequency AT&T Mobility environments. NOTICE Ref: FCC 47 CFR 1.1307(b) Beyond this point: Radio frequency fields at this site exceed FCC rules for human exposure. Four your safety, obey all posted signs and site guidelines for working in radio frequency environments. Ref: FCC 47 CFR 1.1307(b) DC12-48-60-RM NOT USED SCALE: NTS SCALE: NTS SCALE: NTS SCALE: NTSVERTIV RECTIFIER 6SCALE: NTS 31 . 4 1 " 13 . 5 0 " MO U N T 18.28" 10.24" DIA. MOUNTING BRACKET BY MANUFACTURER RAYCAP DC9 OVER VOLTAGE PROTECTOR WITH DOME COVER MANUF: RAYCAP DESC: DC SURGE PROTECTOR "SQUID" WEIGHT:28.7 LBS DOME SECURING BAND CLIP FOR ATTACHING DC9 (OVP) TO BASE ASSEMBLY (TYP) RAYCAP SUPPLIED BASE ASSEMBLY POWER CABLE INGRESS PORTS CABLE TIE BAR RAYCAP DC9-48-60-24-8C-EV (SQUID) DETAIL 4SCALE: NTS RAYCAP DC12-48-60-RM (V2) MAUFACTURES: MODEL: DIMENSIONS: H X W X D (IN) WEIGHT (LBS): NOMINAL OPRATION VOLTAGE: VOLTAGE PROTECTION RATING: RAYCAPS DC12-48-60-RM (V2) 3.48" X 17.23" X 15.40" 27.0 LBS 48 VDC 700 VOLTS REVISIONS REV DATE DESCRIPTION 0 08/16/22 ISSUED FOR REVIEW 90% SITE #: IDL04328 SITE NAME: REXBURG STEINER ELEVATOR FA #: 10133809 164 WEST 1ST NORTH REXBURG, ID 83440 INT JG Smartlink LLC 1997 Annapolis Exch.Pkwy # 200 Annapolis, MD 21401 Tel: 410-263-LINK (5465) Fax: 410-263-5470 www.smartlinkllc.com 706308 1 09/21/22 ISSUED FOR FINAL JG C-6 EQUIPMENT DETAILS 2 1 ANTENNA INFORMATION ANTENNA INFORMATION SCALE: NTS SCALE: NTS 4SCALE: NTS 3SCALE: NTSC-BAND ANTENNA STACKED DETAIL MANUFACTURER NOKIA MODEL #AEQK DIMENSIONS (HxWxD) 29.53" x 17.72" x 9.45" NET WEIGHT <99 lbs (WITHOUT MOUNTING BRACKETS) OPTICAL PORTS 2 x SFP28, 10/25GE eCPRI FREQUENCY 3700-3980MHz MANUFACTURER NOKIA MODEL #AEQU DIMENSIONS (HxWxD) 29.53" x 17.72" x 9.45" NET WEIGHT <99 lbs (WITHOUT MOUNTING BRACKETS) OPTICAL PORTS 2 x SFP28, 10/25GE eCPRI FREQUENCY 3450-3550 MHz 1' - 0 " 2' - 6 " 2' - 6 " EXISTING 2-3/8" (O.D.), SCH. 40 PIPE MOUNT AEQK ANTENNA SEE DETAIL 1 FOR ANTENNA DETAILS AEQU ANTENNA SEE DETAIL 2 FOR ANTENNA DETAILS TOP FRONT BOTTOM SIDEBACK 17.72" 29 . 5 3 " 9.45" TOP FRONT BOTTOM SIDEBACK 17.72" 29 . 5 3 " 9.45" NOT USED REVISIONS REV DATE DESCRIPTION 0 08/16/22 ISSUED FOR REVIEW 90% SITE #: IDL04328 SITE NAME: REXBURG STEINER ELEVATOR FA #: 10133809 164 WEST 1ST NORTH REXBURG, ID 83440 INT JG Smartlink LLC 1997 Annapolis Exch.Pkwy # 200 Annapolis, MD 21401 Tel: 410-263-LINK (5465) Fax: 410-263-5470 www.smartlinkllc.com 706308 1 09/21/22 ISSUED FOR FINAL JG E-1 ELECTRICAL DIAGRAM 3SCALE: NTSDC POWER & FIBER SINGLE LINE DIAGRAM EXISTING POWER PLANT RACK TO SOURCE TO SOURCE EXISTING 200A POWER PROTECTION PANELEXISTING 200A, 120/240V, 1 PHASE METER EXISITING CONDUIT 200A 1" EMT EXISTING CONDUIT CONDUCTOR NOTES: 1. ALL CONDUCTOR SHALL BE COPPER. 2. ALL WIRING SHALL BE COPPER WITH THHN/THWN DUAL RATED 600 VOLTS INSULATION. 3. CONDUCTORS SHALL BE 12 AWG MINIMUM UNLESS SPECIFICALLY NOTED OTHERWISE. 4. GROUNDING CONDUCTORS SHALL BE SOLID TINNED COPPER UNLESS OTHERWISE NOTED. 2SCALE: NTSEXISTING PANEL SCHEDULE RECTIFIER #1 15 13 11 23 21 19 17 24 16 22 20 18 14 12 DESCRIPTION DESCRIPTIONNo. 5 3 7 CKT. 9 1 8 10 No. 6 4 2 CKT. A/P CB 30 2 A/P CB 35 2 RECTIFIER #3 25 27 29 26 28 30 30 2 2 2 2 PROPOSED PANEL SCHEDULE1SCALE: NTS 31 33 35 37 39 41 32 34 36 38 40 42 SPARE SPARE SPARE SPARE SPARE SPARE SPARE 30 30 30 HVAC UNIT #1 15 13 11 23 21 19 17 24 16 22 20 18 14 12 DESCRIPTION DESCRIPTIONNo. 5 3 7 CKT. 9 1 8 10 No. 6 4 2 CKT. A/P CB A/P CB 25 27 29 26 28 30 31 33 35 37 39 41 32 34 36 38 40 42 RECTIFIER #2 RECTIFIER #4 RECTIFIER #5 RECTIFIER #6 RECTIFIER #7 RECTIFIER #8 RECTIFIER #9 GFCI SPARE SPARE 20 1 30 2 30 2 30 2 30 2 35 2 HVAC UNIT #2 20 1 RECEPTACLES 20 1 INTERIOR / EXT. LIGHT 20 1 EXTERIOR LIGHT 20 1 BLOCK HEAT 20 1 BATT CHARGE SPARE SPARE SPARE SPARE SPARE RECTIFIER #1 30 2 35 2 RECTIFIER #3 30 2 2 2 2 SPARE SPARE SPARE SPARE SPARE SPARE SPARE 30 30 30 HVAC UNIT #1 RECTIFIER #2 RECTIFIER #4 RECTIFIER #5 RECTIFIER #6 RECTIFIER #7 RECTIFIER #8 RECTIFIER #9 GFCI 20 1 30 2 30 2 30 2 30 2 35 2 HVAC UNIT #2 20 1 RECEPTACLES 20 1 20 1 EXTERIOR LIGHT 20 1 BLOCK HEAT 20 1 BATT CHARGE SPARE SPARE SPARE SPARE SPARE RECTIFIER #10 30 2 REVISIONS REV DATE DESCRIPTION 0 08/16/22 ISSUED FOR REVIEW 90% SITE #: IDL04328 SITE NAME: REXBURG STEINER ELEVATOR FA #: 10133809 164 WEST 1ST NORTH REXBURG, ID 83440 INT JG Smartlink LLC 1997 Annapolis Exch.Pkwy # 200 Annapolis, MD 21401 Tel: 410-263-LINK (5465) Fax: 410-263-5470 www.smartlinkllc.com 706308 1 09/21/22 ISSUED FOR FINAL JG G-1 TYPE VV TYPE GT TYPE TA TYPE GY TYPE GR TYPE VN TYPE NC TYPE VS TYPE VB TYPE SS TYPE PT NOTE: ERICO EXOTHERMIC "MOLD TYPES" SHOWN HERE ARE EXAMPLES. CONSULT WITH PROJECT MANAGER FOR SPECIFIC MOLDS TO BE USED FOR THIS PROJECT. TYPE 2-YA-2 TYPE XA TYPE YA-2TYPE HS 0. 0 0 0 " 0. 5 0 0 " 1. 5 0 0 " 2. 5 0 0 " 3. 5 0 0 " 4. 5 0 0 " 5. 5 0 0 " 6. 5 0 0 " 7. 5 0 0 " 8. 5 0 0 " 9. 5 0 0 " 10 . 5 0 0 " 10 . 5 0 0 " 10 . 5 0 0 " 0.500" 1.250" 2.000" 2.875" 3.500" 1.125" 0.000" 4.000" 56.20 (4) 437.00 (26) NO. 4150A414 INSULATION NO. WBKT1 WALL BRACKET 1.50"1.00" NOTE: DO NOT INSTALL CABLE GROUND KIT AT A BEND FROM ANTENNA JUMPER (TYP) APPROVED GROUNDING KIT (TYP) ANTENNA CABLE TRAY TO CABLE TRAY (TYP) FROM ANTENNA FRAME SUPPORT #2 AWG BCW BONDED TO GROUND WIRE ALONG CABLE TRAY #6 AWG #2 AWG BCW GROUNDING BAR MOUNTED NEAR ANTENNAS GROUNDING DETAILS APPROVED WEATHER PROOFING KIT (TYP) TYPICAL GROUNDING SCHEMATIC 4 1 5 2 7 6 3 EXOTHERMIC WELDING 12" & 18" GROUND BARS NOT USED COAX GROUNDING DETAIL NOT USED MECHANICAL LUG CONNECTION EXISTING GROUND LEVEL EXISTING GPS SURGE PROTECTION EXISTING #6 AWG STRANDED COPPER CONDUCTOR WITH GREEN, 600V, THWN-2 INSULATION, GROUNDED TO GROUND BAR WITH 2-HOLE COMPRESSION LUG EXISTING FIBER CABLE TRAY EXISTING RAYCAP DC6-48-60-RM SURGE PROTECTION EXISTING 2"X20" DC BUS BAR BONDED TO "P" SECTION OF THE CELL REFERENCES GROUND BAR (CRGB) WITH #2 AWG WIRE AND 2-HOLE COMPRESSION LUG Raycap EXISTING LTE BBU EXISTING eAM ALARM MODULE Raycap Raycap Raycap Raycap TOWER EXISTING GROUND BAR AT BASE OF TOWER EXISTING #2 AWG GROUND LEADS (GC TO FIELD VERIFY) NOTES: 1. ALL HARDWARE BOLT, NUTS, LOCK WASHERS SHALL BE STAINLESS STEEL. ALL HARDWARE ARE TO BE AS FOLLOWS: BOLT, FLAT WASHER, GROUND BAR, GROUND LUG, FLAT WASHER AND NUT. 2. COPPER SHIELD, ANTIOX, CR NO-OX OR EQUIVALENT SHALL BE PLACED WHERE ALL DISSIMILAR METALS CONNECT. 3. ALL LUGS TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4. ALL RRH GROUND WIRES SHALL BE #2 GREEN STRANDED. 5. ALL GROUND LUGS SHALL BE 2-HOLE, LONG BARREL. 6. OUTDOOR GROUND LUGS SHALL BE BLACK HEAT SHRINK W/O INSPECTION HOLES. 7. INDOOR GROUND LUGS SHALL BE CLEAR HEAT SHRINK W/ INSPECTION HOLES. WIRE SIZE BURNDY LUG BOLT SIZE #2 AWG SOLID TINNED #2/0 AWG STRANDED #4/0 AWG STRANDED #2 AWG STRANDED YA3C-2TC38 YA2C-2TC38 YA26-2TC38 YA28-2N 3/8"-16 NC S 2 BOLT 3/8"-16 NC S 2 BOLT 3/8"-16 NC S 2 BOLT 3/8"-16 NC S 2 BOLT BURNDY TWO HOLE LUG W/ LONG BARREL FOR #2 AWG STRANDED OR EQUIVALENT BARE WIRE TO BE NO-0X AT BOTH ENDS #2 AWG STRANDED GREEN INSULATION HEAT SHRINK (CLEAR) BURNDY GROUND LUG (SEE TABLE FOR SIZE AND MODEL) NUT (TYP) LOCK WASHER (TYP) GROUND BAR BOLT (TYP) GROUNDING CONDUCTOR SCALE: NTS SCALE: NTS SCALE: NTS SCALE: NTS SCALE: NTS SCALE: NTS SCALE: NTS #2 AWG GREEN STRANDED GROUND FROM RRH TO SECTOR GROUND BAR (TYP) EXISTING SECTOR GROUND BAR (TYP) EXISTING #2 AWG GROUND LEADS (GC TO FIELD VERIFY) #2 AWG GREEN STRANDED GROUND FROM DC9 TO SECTOR GROUND BAR EXISTING DC6 RAYCAP EXISTING LTE ANTENNA INTEGRATED WITHIN: AIRSCALE MAA 64T64R 192AE N77 200W AEQK, AEQU PROPOSED AEQK+AEQU STACKED ANTENNAS EXISTING RRH UNIT EXISTING RRH UNIT PROPOSED DC9 RAYCAP EXISTING LTE ANTENNA