HomeMy WebLinkAboutRICKS COLLEGE (BYUI) BENSON – BASEMENT REMODEL – PROJECT MANUAL - 1988RICKS COLLEGE Cr BASEMENT REMODEL R EX B UR G, IDA HO PROJECT MANUAL ICKS PROJECT NO. 7142 3 0101 CSHQA JOB NO. 8776 SET No. __19L_ A i Ir'I [C-i- _. August 26, 1088 PROJECT MANUAL FOR PLANT SCIENCE BUILDING BASEMENT REMODEL RICKS COLLEGE Rexburg, Idaho OWNER RICKS COLLEGE Rexburg, Idaho 83440 ARCHITECTS CSHQA Architects/Planners 150 S. Arthur - Suite 207 Pocatello, Idaho 83204 STRUCTURAL ENG. L. H. Bai l iT Associates P.O. Box 4052 Pocatello, ID 83201 MECHANICAL ENG. Engineered Systems 315 West Center Pocatello, IL' 83204 APPROVALS V \�- " HRISTENSEN / President, Ricks College ELECTRICAL ENG. Nielson Engineering 120 N. 12th Ave. - Pocatello, 1D 83201 DR. D. KIM BLACK / Ag. Division Chairman, Ricks College Date . - 1171fF- ate Cz'I — AVC, I58e CHARLES I. FROST Director, Physical Plant, Ricks College Date EL 70�ZINSAdministrator, C.E.S. Date PLANT SCIENCE BASEMENT REMODEL RICKS PROJECT NO. 7142 31 0101 CSHQA JOB NO. 8776 Copy No. _ r 4 ' _ 4 1 CONTENTS COVER TITLE PAGE AND SIGNATURES INDEX DIVISION 1 - GENERAL REQUIREMENTS 1B. 1-7 MP Instructions to Bidders P1' 1-4 Campus Map - GC/ 1-43 corm of Proposal SGC/1-4 General Conditions pB;l_2 Supplementar Performance y General Conditions /1-3 Bond -:� Labor and Material Payment Bond PE PE Contract for Construction Progress Estimate DIVISION 2 - SITE WORK 02070 Selective Demolition DIVISION 3 - CONCRETE 03310 Concrete DIVISION 4 - MASONRY DIVISION 5 - METALS 0.5120 05400 Stri)ctural Steel 05500 Cold -Formed Metal Framinq_ Metal Fabrication 05520 Handrails and Railings DIVISION 6 - WOOD AND PLASTICS 06100 Rough Carpentry 06200 Finish Carpentry 06400 Architectural Woodwork DIVISION 7 - THERMAL AND MOISTURE PROTECTION 07200 Insulation 07510 Built-up Asphalt Roofing Systems 07600 Flashing and Sheet Metal 07700 Roof Specialties and Accessories Joint Sealers DIVISION 8 - DOORS AND WINDOWS 08110 Steel Doors and Frames 08210 Woad Doors 08410 Aluminum Entrances and Storefronts 08710 Finish Hardware 08800 Glass and Glazing DIVISION 9 - FINISHES 09510 Acoutical Ceilings o9635 Brick Flooring 09650 Resilient Flooring 09900 Painting DIVISION 10 - Not Used. DIVI'tiION 11 - Not Used. DIVISION 12 - Not Used. DIVISION 14 - Not Used. DIVISION 15 - MECHANICAL DIVISION 16 - ELECTRICAL INSTRUCTIONS TU 131JUER5 SECTION 1 -- BIDDING BY INVITATION a. Bidding shall be by written invitation only. Those desiring to be considered for such invitation shall make written application thereof to: Physical Plant Director Ricks College Rexburg, Idaho 83440 b. The fact a Bidder is recognized as qualified to bid will not guarantee such Bidder will be invited to bid, nor will prequalification of, or invitation to a Bidder guarantee award of the contract to such Bidder -should it be determine that he is the low Bidder. SECTION 2 -- CONTRACT DOCUMENTS a. Contract documents (plans and specifications) may be obtained by contractors from: Physical Plant Director Ricks College Rexburg, Idaho 83440 b. A deposit of $l 00.00 paid in advance, will be required on each complete set of documents taken, with a limit of three (3) sets. Cash deposit requirement is waived for members of the Associated General Contractors. c. Subcontract Bidders and material suppliers who desire to obtain contract docu- ments (plans and specifications) or parts thereof, for their exclusive use, may do so by requesting same in writing and paving costs of printing to the appro- priate institution as identified in paragraph "a" above. d. All contract documents must be returned to the place from which they were issuer within fifteen (15) days after the bid opening, or the deposit will be forfeiter Those documents purchased outright by the Bidders are exempted. THE CHURCH OF JESUS CHRIST OF LATTER-DAY SAINTS RICKS, PLANT SCIENCE REMODEL CHURCH EDUCATIONAL SYSTEM INSTRUCTIONS TO BIDDERS 1B/1 Contract documents at no charge at one r=or,struction Section Phvsicsl Plant Department 229 Brewster Building Provo, UT 84602 (plans and specifications) may be examined of the following places: CSHGA ARCHITECTS/PLANNERS 150 S. Arthur - Suite 207 Pocatello, ID 63204 ( 208) 232-15981 A.G.C. 110 North 27th St. Boise, ID 63706 (206) 344-2531 Intermountain Contractor Idaho Branch 415 N. Curtis Road Boise, ID 63706 (208) 377-5272 Dodge/Scan Plan Room 1935 East Vine - Suite 250 Sait Lake City, UT 84121 ( 801) 278-5333 Section 3 -- CONTRACT METHOD Physical Plant Director Ricks College Rexburg, ID 83440 A.G.C. Capital Ave. Idaho Falls, ID 63402 ( 2108) 529-2320 A. G. C. 1135 South West Temple P.O. Box 1046 Salt Lake City, UT 64115 Intermountain Contractor 1743 W. Alexander St. P.O. Box 26237 Salt Lake City, UT 84126-0237 (601) 972-4400 All work specified is to be performed under and bids will be accepted by Owner from prime STANDARD CONTRACT DOCUMENTS Revised January 1, 1982 one general contract, contractors only. THE CHURCH OF JESUS CHRIST OF LATTER-DAY SAINTS CHURCH EDUCATIONAL SYSTEM INSTRUCTIONS TO BIDDERS IB/2 SECTION 4 -- INTERPRETATION OF CONTRACT DOCUMENTS a. If any prospective Bidder is in doubt as to the true meaning of any of the contract documents, or finds errors, discrepancies in, or omissions from them, he shall submit to the below listed office of the appropriate insti- tution a written request for interpretation or correction. ANY INTERPRETATIONS OR CORRECTIONS WILL BE MADE ONLY BY WRITTEN ADDENDUM DULY ISSUED BY THE -BELOW LISTED OFFICE. A copy of such addendum will be mailed or hand delivered-io each person receiving a set of contract documents from the Owner. Requests for such interpretation or correction must be in the appropriate below listed office no later than five (5) days before bid opening. Physical Plant Director Ricks College Rexburg, Idaho 83440 b. Should discrepancies appear in the contract documents which are not resolved by addendum, then it is expressly understood that the Contractor has used the most expensive method and/or material in his bid. SECTION 5 -- REQUIREMENTS BEFORE SUBMITTING PROPOSAL The Contractor will become thoroughly familiar with the site and structures locate: thereon (if any) and all contract documents shall be thoroughly examined in re- lation to all conditions which might directly or indirectly affect the contract work. The proposal sum shall reflect all such conditions. SECTION 6 -- PROPOSALS To receive consideration, a proposal must be made in accordance with the following instructions: ` a. Proposals shall be made on a separate proposal form, specifically written for the project being bid. b. Proposals shall have all items or blanks filled in. Numbers shall be stated both in writing and in figures. c. The completed proposals shall be without interlineations, alterations, and erasures. d. The signatures shall be in longhand and by those duly authorized to execute the Contract. e. Proposals will not contain any recapitulation of the work to be done-. Al- ternative proposals will not be considered unless specifically requested. STANDARD CONTRACT REQUIREMENTS Revised January 1, 1932 THE CHURCH OF JESUS CHRIST OF LATTER-DAY SAINTS CHURCH EDUCATIONAL SYSTEM INSTRUCTIONS TO BIDDERS IB/3 PROPOSALS Continued) will be consider( SECTION 6 - or modifications telegraphic or telephonic.proposals f. No oral, Proposal is received at to see that his p p. time will be re- 9- is the Bidder's sole resp onsibility erring g' o er time. Any bid received after the schedule oP the proper erred. turned to the Bidder unop those subcontractors who have demon - are financially capable of handl- t from °nly past experience, any h. Bidders shall accep proposals eey nnel, plant, p strated to the Bidder's technicalt ability, pers It will be assumed thatath' ing the work, have the portions of the work. ry out their p ro osal: reputation to carry contractors, where cons beeneresolvedabeforenpcoP P question of bondinga d the cost of such bonds has by the Contractor, where haye been submitted to the Owner. with his proposal, a list of subcWi�hatherdollar ro osal) together ro osal. i. Each Bidder shall equired,on the form °f him in formulating his Proposal' provided, and if required amounts of their bids which were used by waive any or to right to reject any or all proposals, er re5erves the The Owner reserves the rig received. Thebest serve the he irregularities or informalities in proposals in the Owner's opinion,the lowest cub- e t the pr°POsal that will, is Tight to accept re ardless of whether such Proposal interests of the Owner, g mitted. and telephone number shall be Stated k. .the Bidder's legal name, business address, in full. 'two or more bidders bidding a to be considered valid, written approval of the joint l In order for the proposal their bid. All members of a a,joint venture" must have the Dint riot to submitting office as listed heren prior proposal and an official representative of the venture shall sign theP p Proposal.- venture shall be designated in the pro P physical Plant Director Ricks College 83440 gexburg, the work contained in 1- e understood to include all -rhe contract wi The term "base bid shall b an alternates or substitutes• alternates or M. excluding Y without reference to contract documents, �+base bid" only be awarded on the basis of the con ted by the .Owner may xecuted - substitutes. be in in contra acce a Change order or form of part of the e n Any substitutes or alternates P tract documents either by agreement. person or by a written real either in p Once opened, t ° proposals may be withdrawn by the Bidder, of proposalsdays a n after open: but not after the time fixed O2 opening - prior to, drawn and must remain fixed as submitted for 30 y CHFIST OF may not be with OF JESUS THE CHURCH UIRa ENTS LATTER-DAY SAINTS STANDARD CONTRACi'R1982 C CH EDUCATIONAL SYSTEM Revised January INSTRUCTIONS TO BIDDERS IB/4 - — PROPOSALS (Continued c• Envelopes must contain nothing but the proposal. shall be opaque, bear theBidder'sF F a-, - ,res identified as name, - follows; be sealer, arL,f Ricks College Plant Science BuiIdinq Basement Rem,_,de1 Proiect #7142 31 0101 P. Proposals will be received prior to 1:30 p.m., Se 1988, MDT; at the office of ptember the Physical plant Director, and will be opened immediately there after in Room #212 Physical Plant Building, of the SECTION 7 -- APPROVAL OF SUBCONTRACTORS a• As soon after the bid opening as practicable, interview the the Owner will aoParent low Bidder and if deemed advisable, the second or third low Bidders. The will be examined. The Owner reserves the trigl-itut00 00 reject any subcontract proposal. oacceptor b. In case a Bidder has any doubt regarding the correctness or acceptability of any subcontract proposal, the Bidder submit the names and amount m`ay subcontractors, making sure h°f other come=tinc owever, that he clearly sates which one he has used in formulating his proposal. SECTION 8 -- FACTORS AFFECTING CONTRACT AWARD The Bidder's and eubcontractor's past performance, organization, equipment, and ability to perform and complete their contract in the manner and within the time specified will be vital elements, together with the amount of their bids, in the award of the contract. SECTION 9 -- PERFORMANCE BOND AND LABOR A14D MATERIALS PAYMENT BOND The Contractor will be required to furnish to Performance bond and a labor and materials the 0``.`Fr a bond shall be in an amount equal to 100� of tr1payment bond. Each security for the faithful contract sum; and be Payment of all obligations arising,thereund�r• the contract and the issuing the bond will be subject to The surety comranv Bond shall be based the approval of the documents; preferably, on the forms bfilling jned in the. contrThe cost of such bonds shall be the obliy in the blanks, Try they shall be furnished and approved of within ten the Contractordaysr the execution of the contract. STANDARD CONTRACT DOCUMENTS Revised January 1, 1982 THE CHURCH OF JESUS CHRIST OF LATTER—DAY SAINTS CHURCH EDUCATIONAL SYSTEM INSTRUCTIONS TO BIDDERS Tnir SECTION 10 -- PRIOR APPROVALS AND SUBSTITUTIONS a. In order to est ablish a standard, wherever possible three or more accehave ptable of equipment, manufactured articles orsuchsuchdcases, its of tiscnot nintended brands q against other brands ' agedlbecausemith�tsin been identified in the contract documents. to close the trconsct ideration.ents agCompetition which may the Owner's interest. for prior approval of items not explicilfhec b. Prior Approvals: 'Requests P the seventh day preceding Toval shall The requests for prior approval may be made to the Architect ehitect p t to and time permits. They are not date on which bids Engineer if be considered by the Architect and/or g. bound to give consideration to these proposals hnical data, references, and information shall be furnished c. Fully detailed technical nests for prior approval items. simultaneously with the requests or Engineer . en due consideration by the Architect and/ d. Such requests wllbe t of acceptance, will be included in an addendum. i and Owner and, the evenof only those items ied or which have received prior approval by e. The Contractor's "base bid" shall include the furnishing which are ex licitl s ecif addendumion to the - „base any equipment. or material at his opton, submit a f. Substitutions: (contractor or subcontract or, may, a feels warrants consideratic supplier and any c item specified which h substitute proposal for any by the Owner. This proposed substitution is to be listed where indicate on the form of proposal. ractor shall inc the amount g. Any l,�oposed subst itute submitted by a cont sada substitute.bv which the "base bid" would be added to or deducted from by ro osed; however, in determining accept or reject any substitute p P h The Owner may P ward of the Contract. one the "base bid" will be considered. Substitutions willnot the low Bidder, Y be considered in determining the low Bidder or shall furnish in- i. On demand of the Owner, the Contractor, at his own him asnaesubstitute. If the the item offered by ense, shall have said formation or data concerning the at his own eXp h sical and performance Owner shall so require, owner as to its physical item tested under the dirtesting of the la oratory. characteristics by an approved SECTION 11 -- LOCAL LABOR both possible. employ student and other labor The Contractor shall, insofar as is P the common and skilled, referred to him by the Last shall lbeemade through such labor is competent. The request far s Institution's Placement Center. THE CHURCH OF JESUS CHRIST OF STANDARD CONTRACT REQUIREMENTS LATTER-DAY SAINTS 'IE Revised January 1, 1982 CHURCH EDUCATIONAL SYS%1 INSTRUCTIONS TO BIDDERS TA IF; SECTIOf� 12-- FORM OF CONTRACT The form of contract, which the successful Bidder, as :, Contractor, will be required to execute, will be based on the form _,�;c herewith in the specifications. 't, SE'TI;:,-PN 13 -- LIQ ,IDATED DAMAGES AGEt. a. It is recognized and agreed by the parties hereto that it ; Of importance to the Owner to have this project comt.Leted within the time schedule agreed upon; that the Owner will be materially damaced if the project is not completed in compliance therewith; and that the exact nature and amount of the damages which will result from anv delay in the completion thereof within the time specified are uncertain and difficult, if not impossible to ascertain. Therefore, if said time schedule is not adhered to by the Contractor, r.lus an additional time which may be allowed by written exfensi'n. siqned by the Owner's Representative, the Contractor shall pay to the Owner as fixed, agreed, and liquidated damages (and not as a penalty) the followinQ: L100.00 per each and every calendar day the project remains uncompleted. b. Said liquidated damage provision shall remain in effect and continue until final completion and acceptance of tree pro=e: by the Owner. The Contractor hereby authorizes the Owner to retain sufficient amounts of the moneys due if and remaining in hands of the Owner to pay the damages caused default or defaults, by any such C. The work shall be completed on or before February 1, 1989. SECTION 14 -- ADDENDA Any addenda issued during the time of bidding, or forming a part of the contract documents, loaned to the Bidder for the preparation of his proposal, shall be covered in the proposal and shall be ma part of the Contract, d= a SECTION 15 -- REQUIREMENTS IMMEDIATELY AFTER SIGNING THE CON_TzA-T Immediately after entering into a contract with the Contractor shall furnish the following: Owner, the a• An executed performance bond and an executed labor and materials payment bond, each in an amount equal to one hundred percent (100.%) of the contract sum as called for in Section 9 above. STAINDARD CONTRACT DOCUMENTS Revised January THE CHURCH OF JESUS CHRIbT OF LATTER—DAY SAINTS CHURCH EDUCATIONAL SYSTEM INSTRUCTIONS TO BIDDERS IB/7 called for in the gene_ b, sl Insurance certificates as to bidders for ea=r' conditions and/or special instructions project. oproposal into its var:ovs f the total C. Acost breakdown W„rk which may serve as a basis for mc` '=r�` components of the monthly payments to the Contractor. STANDARD CONTRACT DOCUMENTS Revised January 1. 198Z THE CHURCH OF JESUS C'r.R_ST OF LATTER-DAY SAINTS i�TEN CHTiRCH EDUCATIONAL INSTF.UCTIONS TO PID�En- IP./8 MP FORM OF PROPOSAL NAME OF PROJECT: PLANT SCIENCE BUILDING, BASEMENT REMODEL PROJECT NUMBER: 7142 31 0101 NAME OF CONTRACTOR: DATE OF PROPOSAL: The undersigned, hereinafter referred to as the Bidder, certifies that the following facts and/or circumstances have occured or exist relating to the proposed work for the Plant Science Basement Remodel for Ricks College, Rexburg, Idaho, prepared by CSQHA ARCHITECTS/ PLANNERS, 150 S. Arthur - Suite 207, Pocatello, ID 83204. 1. That Bidder has received the Contract Documents for the above entitled project as listed in the Table of Contents. 2. That Bidder is familiar with such Documents, has examined the site of the proposed work, including availability of access, utilities, and other similar items relating to performance of the work and is thoroughly familiar with all general and local conditions which could in any way affect this work. 3- That no verbal agreements or representations with or by any Officer, agent or employee of the Owner exist or have been made to the Bidder and the Bidder in submitting this propo- sal is in no way relying thereon. 4. That if this proposal is accepted, Bidder will enter into a Contract with the Owner in substantially the form contained in the Contract Documents, and will provide the bonds, in- surance coverage and all other items required by the Contract Documents. 5. The term "base bid" shall be understood to include all work contained in the Contract Documents excluding any substitutes. The Contract will be awarded on the basis of basis of base bid only, without reference to substitutes, or alternates. Bidder hereby proposes to furnish all materials1. , labor, equipment, plant, tools, transportation, services, licenses and permits necessary for the completion of all work set forth in the Contract Documents for the sum of: BASE BID PLANT SCIENCE BASEMENT REMODEL RICKS COLLEGE THE CHURCH OF JESUS CHRIST OF LATTER-DAY SAINTS CHURCH EDUCATION SYSTEM FORM OF PRnPnSar. pi, AS FURTHER CONDITIONS OF THIS PROPOSAL: 1989. work on or before January 12 1. The Bidder agrees to complete the liquidated 2. The Bidder is aware of and agr ees to, the provisions of damages set forth in Section 19 of the Instructions to Bidders. wledges receipts of addendas No. (s) prepa inclusive and has 3. The Bidder ackno considered the same in p to of this proposal. agrees to furnish the performance and labor and material 4. The Bidder agreeQuired in Section 14 of the Instructions to Bidders. payment bon S. The Bidder contractor's license statenumber of is: Such license is issued by THE CHURCH OF JESUS CHRIST PI,p,NT SCIENCE BASEMENT nMODEL OF LATTER-DAY SAINTS CHURCH EDUCATION SYSTEM RICKS COLLEGE FORM OF PROPOSAL P/2 PROPOSED SUBSTITUTE MATERIALS The total sum of the Bidder's proposal installing of all materials, equipment, Contract documents as a base bid. shall include the furnishing and and labor as called for in the Hereafter give the total amount to be added or deducted for a complete installation of equipment or materials other than those specified and those approved by addendum are submitted for the Owner's consideration. All materials and equipment proposed for substitution shall be listed below and must meet the requirements of the Contract Documents. During the time of consideration of the proposals, complete information shall be submitted immediately to the Architect and Owner's Representative. The Contractor is referred to Section 10 of the Instruction to Bidders, Substitution," for requirements relative to proposed substitutions. Proposed Manufacturer and $ Add $ Deduct Substitutes Catalog Numbers PLANT SCIENCE BASEMENT REMODEL THE CHURCH OF .IESUS CHRIST RICKS COLLEGE OF LATTER-DAY SAINTS CHURCH EDUCATION SYSTEM FORM OF PROPOSAL P% 3 g^ODER'S ORGANIZATION PEF BID Official Name of Organization Corporation, Co -partnership, I vid� or Other Address Name of Individual Members of Firm: Name of President of Corporation: Name of Secretary of Corporation: the laws of the State of: P Cor oration is organized under SIGNATURE MUST BE AFFIXED HERE: Signature Title or Office Legal Address TEIE CHURCH OF JESUS,CHRIST OF LATTER-DAY SAINTS PLANT SCIENCE BASEMENT REMODEL CHURCH EDUCATION SYSTEM RICKS COLLEGE - FORM OF PROPOSAL P/4 GENERAL CONDITIONS OF THE CONTRACT THE CHURCH OF JESUS CHRIST OF LATTER-DAY SAINTS CHURCH EDUCATIONAL SYSTEEN1 TABLE OF CONTENTS TITLE General SECTION NO. Principles and Definitions 1 Additional Information, Work Schedule, and Discrepancies 2 Ownership of Drawings and Models 3 Materials and appliances 4 Royalties and Patents 5 Shop Drawings 6 Sample 7 Manfacturer's Directions and Guarantees 8 Coordination of Work 9 ' Examine Site 10 Easements, Permits, and Certificates 11 Grades, Lines Levels and Layout 12 Clarification of Contract Limit Line 13 Permanent Utilities 14 As Built Drawings and On Site Contract Documents 1S Status and Responsibility of Owner's Representative 16 Architect's Status and Decisions 17 Relations of Contractor and Subcontractor 18 Contractor's Supervision 19 Payments to Contractors 20 21 THE CHURCH OF JESUS CHRIST OF LATTER-DAY REVISED: SAINTS CHURCH EDUCATIONAL January 1 i.982 SYS7B.Nj , TABLE .OF CONTENTS TC/1 SECTION NO. TITLE 22 Changes in the Work 23 Cash Allowances 24 Damages 25 Claims for Extra Cost 26 Deductions for Uncorrected Work 27 Separate Contracts 28 Work by Others 29 owner's Withholding of Payments 30 Owner's Right to do Work 31 Owner's Right to Terminate Contract Right to Stop Work or Terminate Contract 32 Contractor's 33 Arbitration 34 Strikes and Lockouts 35 Delays and Extension of Time 36 Correction of Work Before Final Acceptance 37 Correction of Work After Final Acceptance 38 Liens 39 Assignment 40 Occupancy Before Completion 41 Building Codes and Regulations 42 Inspections and Tests 43 Use of Premises and Storage 44 Protection of Work and Property 45 Protection of Lives and Health THE CI RCH OF JESUS CHRIST OF LATTER-DAY SAINTS CHURCH =UCATIONAL SYSTr1 TABLE OF CONTENTS REVISED: TC/2 " January 1, 1962 TITLE SECTION NO. Miscellaneous Services by the Contractor 46 Cutting, Patching and Digging 47 Bonds 48 Building Risk 49 Liability Insurance = 50 Builders Risk Insurance,0ver One Million Dollars 51 Builders Risk Insurance, Under One Million Dollars 52 Hold Harmless Agreement 53 Taxes 54 WorkTtn 55 Contractor Parking 56 Traffic Control 57 Internal Combustion Equipment 58 Mechanical Equipment Back-up Alarms 59 Dust Palliation 60 Refuse 61 Fire Hydrants 62 Glass Breakage- 63 Elevator Maintenance 64 Sunday Work 65 Domestic Steel 66 Cleaning Up 67 REVISED: January 1, 1982 0 THE CF?URCH 'OF JESUS CHRIST OF LATTER-DAY SAINTS CHURCH EDUCATIONAL SYSTal TABLE OF CONTENTS TC/3 SECTION NO - TITLE 68 Items to be Furnished by the Owner 69 Contractor Not Agent of Owner 70 Appointment of Owners Representative actor to Appoint Authorized Agent and Superintendent 71 Contr 72 Inspection = 73 Attorneys Fees 74 Language 75 purchase of Materials by der 76 Severability rJ REVISED i oQ.9 THE CHURCH OF JESUS CHRIST OF LATTER-DAY SAI�7TS CHURCH EDUCATIO:`lAL 5YSTV TABLE OF CO\rrE "''TS TC/ 4 GLNL•RAL CONDITIONS SECTION I GENERAL 17iese General Conditions are hereby cifications with the same force and effect asrifo holly emb die of t1:e Y odied herein.. SECTION 2 PRINCIPLES ANU DEFINITIONS a• Contract Documents: The contract documents consist of zl listed in the Table of Contents and any addenda. 1 docwner�ts are complementary, The contract doc=lcnts ing as if called fornb•wall,ls called for by any one shall be as hin�i- all labor and materials, e The intent of the documents is to include proper execution of the work pallt, and transportation shallnecessary for the workmanship to the highest standards, be equal in quality and comply with the true intent and meaningThe Contractor shall abide by and taken as a whole, and shall not availimselfof ltothedetrim ent Of he work of an drawingsand specifications y manifestly unintentional error or omission, should an,texist. All minor details of ,�ork, which are not shown on the draw' as such items which are not specifically mentioned in tf�cse specifications, but are obviously necessa drawings as well be considered as incidental and the proper completion of the orkshall as being part of the work. b• Conte; 'fie Contract shall consist of the agreement the Owner and the Contractor binding both parties nt executed b contract documents. P to the terns ofytbeth C. Precedence: precedence: (1) (2) (3) Within the contract documents, there shall be the follot.jin S Addenda or modifications in accordance with the terms of the contract documents of any nature, cedence over the original to the drawings and specifications, talc pre - Specifications take precedence over drawings. Within the working drawings, the larger scale takes recede smaller; figured dimensions over scaled• graphic indications. and noted materials cover er be resolved b• However, where conflicts do exist, they shall the Architect. (4) The Architectural drawings shall take precedence over ings and shall govern in all cases where discrepanciestcur, unless oc he other draw - such discrepancies are adjusted before the awarding Of the Contract. THE CIIURCII OF JESUS CHRIST OF LATTER-DAY SAINTS REVISED: CHURCH EDUCATIONAL SYSTL�I January 1, 1982 GENERAL CONDITIONS G/C1 d. S ecification Sections: For the letting of subcontracts, These separations shall not Representative an arbiter to and Subcontractors. thereof shall designate the e. owner: The word "OwneZ" or pronoun is place organization for which the work is being performed. f. Architect: The word "Architect" or pronoun in place thereof shall desig- ion who prepares the contract documents for -e person -or organizat the Owner. 8 Contractor: The word "Contractor" or pronoun in place thereof shall des- ignate the person or organization with whom the Owner contracts to act - plish the work. owner's Representative: The term "Owner's Representative" refers to the h. supervisory responsibilities authorized representative of the owner having for the project. i. Subcontractor: The term "Subcontractor" as to Hiddersed herein, includesexcept only thosedefined for bidding purposes in the Instructions with the Contractor and it intoh includes e who having a direct contract design accordingg contract furnishes material worked to a special documents, but does not include one who merely furnishes material not so worked. Written notice: Written notice shall be deemed to have been duly served:j. - (1) Upon the Contractor if delivered is person to the Contractor's desig- at nated representative or to a member of the fibusiness�or addressdknownred to the or sent by registered mail to the Owner. (2) Upon the owner if delivered in person to the Owner's Representative, or if delivered at or sent by registered mail to the last business address known to the Contractor. k. The owner, Contractor, Subcontractor, and Architect are treated throughout as if each were of the singular number and the the contract documents masculine gender. l• W The term "work" includes all labor, materials, and equipment nec- to produce the construction required by the contract documents, and essary incorporated or to be incorporated in such all materials and equipment so ve construction. Materials or work descrlbshaed ll berheld to h refer pto1such arec- a well known technical or trade 8 ognized standards. convenience or reference and to facilitate specifications are separated into sections. operate to make the Architect or Owner's establish subcontract limits between Contractor THE CHURCH OF JE S US V"` CIS T OF LATTER-DAY SAIVTS CHURCH EDUC?.TIONAL SYS--- GENERA? COI"TDZTIONS REVISED: - 1 1QP9 m. Time Limits: All thtime limits stated in the contract documents arc e essence of the Contract. of °• Law: The law of the place of building governs the construction of work included in the Contract. roc o- Base ; The term "base bid" shall contained in the contract documentsexcldinrsanyod to include alternates orall rs work tutes; the Contract will be awarded on the basis ofbase bubsti- reference to alternates or substitutes. id onl y, without SECTION 3 -- ADDITIONAL INFORMATION WORK SCHEDULE AND DISCS°A1`lCIES a. Architect shall by means Of Job furnish with reasonable instructions, including drawings dal instructions, for the proper execution of the work. grequired, necessary will be consistent with the contract documents, true trueldevelopmentsngs and rtions and reasonably inferable therefrom. thereof, b. The work shall be executed in conformity therewith, and Contr do no work without proper drawings actor shall in advance of the receipt of these detailsdruciio s. Any work constructed Contractor shall be constructed entirely at his own risk. ructions by c. A detailed progress schedule shall be prepared by Contractor before mittal of his first monthly payment the This shall be done on a form and in a manner acceptableub- Owner's Representative, d. The Contractor and/or Owner's Representative, if either so re jointly prepare a schedule, subject to change from time to time einsa shall cord - ante with the progress of the work, fixin s g the dates at which the various detail drawin g will be required, and the Architect will furnish them in accordance with that schedule. ions prepared, fixing the dates for the dsubmission er like noftshop ,drawingsa schedule shall be beginning of manufacture and installation of materials and for, thefor the omple- tion of the various parts of the work. c e. If work is required in a class work lmanner to make it impossible to produce first - the Contractor mustrequesteanninterprecies tationob fore g the contract documents, the work. If the Contractor fails to make such request, nodinexcuseth thereafter be entertained for failure to car will in manner. Should conflicts occur in, or between drawings and satisfactory the Contractor is deemed to have estimated the more expensive way the work unless he shall have asked for and obtained a written decision before submission of Y f doing be required. his Proposal as to which method or ma:erialsswill REVISED. January 1, 1982 THE CHURCH OF JESUS CH_UST OF LATTER-DAY SAINTS CHURCH EDUCATION.A.L SYSM1 GENERAL CONDITIONS CC/3 SECTION 4 - OWNERSHIP OF DRAWINGS A:`TD MODELS spec ifications, and copies thereof, which arc furn- a. All drawings, models, ished to the Contractor except onrtSeof°the onowner. documents e They are not to be Contractor's files, are the p p Y used on other work and are to be returned to the Owner's Representative. ltfurnish Unless otherwise provided in the contract documents, to the Contractor, free of charge, all copies of drawings and specifications reasonably necessary for the execution of the work. SECTION 5 MATERIALS AND APPLIANCES t as otherwise stipulated elsewhere herein, the Contractor shall provide a• labor tools, equipment, light, power, provide and pay for all materials, ? for the execution water, transportation, and other facilitiesnec essaror final payment �, and completion of the work; accompany app es for same have been fully paid receipted bill setting forth that hWater and power waste. Maintain by the Contractor. 'Use care to prevent valves, connections, and hoses in first-class condition. contractor shall, unless other- b. All m_`.erials used by C.,atractor or any Sub wise specified, be new and of the highest quality. All such materials, unless otherwise specified to the contrary must be manufactured in the United States of America. quantity to facilitate proper c. Materials shall be furnished in sufficient q Y and speedy execution of the work• Materials trademarksmust intactbe landrsuch labelsto the iLe in original packaging With labels and and trademarks must remain intact until the material is used. d. Contractor shall, if required, furnish evidence of the quality of any materials, which are is question as to meeting the requirementsof the or contract documents. Same shall be removed from the project Y without expense to Owner, if they are found to be deficient. SECTION 6 -- ROYALTIES AND PATENTS The Contractor shall hold and save the Owner harmless from and against alaLented every demand, of any nature orind for includedrin theaccount materialthe or suppliesany hereby invention, article, or appliancea such agreed to be furnished under this Contract. ebe°requisitesandlnecessary to royalties and secure such valid licenses as ma or material without being enable the Owner to use such invention, article, or in law or equity disturbed or in any way interfered with by any p on account thereof. 0 THE CHURCH OF JESUS CHRIST OF LATTER-DAY SALNTS - CHURCH EDUCATIONAL SYST:='i GENERAL CONDITIONS REVISED: GC/4 .laniia.ry 1. 1982 SECTION 7 -- SHOP DRAWINGS a. Shop drawings are drawin Charts , brochures gs, diagrams, illustrations, schedules and other data which are prepared b 3 performan any Subcontractor, manufacturer Y the Contractor or the work- some portion of , supplier or distributor, which illustrac Contractor. rk. All shop drawings are to be submitted by the b. Any drawings submitted directly to the Architect b Contractor will _be returned without review unlYanyone otothethan the writing by the Owner's Representative. ess specified rwise in c- Submittal procedure for shop drawings: (1) The Owner will provide the Contractor with sheets. The Contractor shall accurate) andlegiblyprpadsepare of trane com- plete set of these transmittal forms (7Ycopies g Y Prepare one com- number each transmittal consecutive) )• The Contractor steal. the Architect all copies of the transmittTh al Corn actor shall ha lCosubmit tc Yellow copy and the Owner's blue copy.Contractor' The s co rfor his own files. The transmittal forms should be attached �pthes for drawings being submitted. shop (2) Simultaneously, with the Contractor's shall submit submittal to the Airchto the Owner, the blue co tect, he one copy of the shop drawings. PY of the transmittal form and (3) The Architect will make his corrections and not r reproducible (if the shopdr ations, Ly an swings were submitted in a reproduciblehe form) and return same to the Contractor using the Contractor's co sub -titled "Final Transmittal." the corrections and notWhen in the Architect'sjudgment' ations are minor in nature, he will put stamp "Approved As Noted" Contractor, on the reproducible, returning same to the ' running a Print of the shop drawings for his own files, and simultaneously sending a print of the shop drawings to the Panied y the Owner's white copy of the transmittal form Owner acccr�- "Final Submittal." sub -titled (4) If the Architect requires corrections to the shop drawings, minor in nature, which would necessitate a re -submittal ofthe tshoo emed drawings, the Contractor shall use a new set of transmittal fora reference that this is a second or subsequent submittal. s makiriz Contractor shall make any corrections required b resubmit the corrected copies of the sho Y Architect and shall ngs Contractor shall direct specific attention inawriti until approved. shop drawings to revisions and corrections req estedgbon re -submitted previous submissions. y Architect on REVISED; January 1, 1982 THE CHURCH OF JESUS CIiR-TST OF LATTER-DAY SAL:ITS CHURCH EDUCATIONAL, SYST` GENERAL CONDITION'S GC/5 I If the Contractor chooses to submit shop drawings on any form that is (5) required* not reproducible, then the following number of copies are req One for the Architect One for the Owner One for the Contractor's Home Office One for the Contractor's Job office shop drawings as are required in As many additional sets of approved the field to expedite the work. are submitted to the Architect, When non -reproducible shop drawingsrovad the shop drawings, shall then the Architect, when he has aPP transmittal fo rn. send a copy to the Owner along with the proper d. By submitting shop drawings, the Contractor thereby represents that he field construction has determined. etermined and verified anlbersdandasimilartdata, or will do so, and criteria, materials, catalog with the requirements that he has checkedtand c coordinated each shop drawing of the work and of royal is e. Do not execute work req uired by shop drawings until written app roved given. All such portions of the work shall be is accordance wit aPP shop drawings. shop drawings show variations from contract remakeements specificcause of mention of f. If P or for any other reasons general standard shop practice, roval will be such variations in submittal letter. Shop drawings apP truction o£ work, furnishing of shall not relieve the Contractor of responsLbilitY for accuracy h sac It proper fitting, shop drawings, nor for p p or, shop materials or work required by contract and not indicroving departuresfrom Shop drawings approval shall not be construed as apP spec__ ifically noted to that e cont ract requirements, unless by in writine by the Architect. rove shop drawings with promptness so as to g. Architect will review and apQ _ concept of the cause no delay, but only for conformance he contract documents. Archi- project and with the information shall not indicate approval of an tect's approval of a separate assembly in which the item functions. h. Shop drawings shall: (1) " x 36" or 8 1/2" x 11" reproducible sheets Where practical, be on 24 to facilitate handling and filing. (2) Where practical, have a space approximately 2 1/2" x 4 1/2" in the lower right hand corner for the Architect's stamp. (3) Be numbered consecutively. REVISED: January 1, 1982 THE CHURCH OF JESUS CHRiST OF LATTER-DAY SAMITS CHURCH EDUCATIONAL SYSTr—% GMNERAL COtMITI0:7S GC," 6 (4) Be dated_ (5) Have project name. (6) Have submitting party's name. (7) Have working and erection dimensions. (8) Have arrangements and sectional views. (9) Have all necessary details including complete information for makin connections to and with other work. S (10) Show kinds of materials and finishes. (11) Have descriptive names of equipment. (12) If applicable, have classified item numbers. (13) Have locations at which materials or equipment are to be installed in the work. SECTION 8 -- SAMPLES a- Samples are physical examples prepared b h manufacturer, supplier or distributor which illustrates ry Subcontractor, materials, equipment or workmanship, and to establish standards by which the work will beg judged. All samples are to be submitted by the Contractor. b. Contractor shall review, and submit, with promptness and in orderly so as to cause no delay in the work or in the work of any other ContractorCe or Subcontractor, all samples required by the contract documents or subse- quently by the Architect. These shall be submitted in accordance with the schedule for submission of samples. C. Submittal procedure for samples: (1) The Owner will provide the Contractor with sheets. The Contractor shall accuratel printed pads of sample complete set of these transmittal forms y(7�colies). bly prepare one shall number each transmittal consecutively.copies). The Contractor submit to the Architect all copies of thetransneittalrformre. cent shall the Contractor's yellow copy and the tor's co Owner's blue copy. The Contrac- py is for his own files. The transmittal forms should be attached to the samples being submitted. (2) Simultaneously, with the Contractor's submittal CO the Architect shall submit to the Owner, the blue copy of the transmittal form and he one copy of the samples. REVISED: January 1, 1982 THE CHURCH OF JESUS CHRIST OF LATTER-DAY SAINTS CHURCH EDUCATIONAL SYST:3i GENERA.. CONDITIONS GC/7 d. By submitting sampl es, Contractor thereby represents that tic. Iias determined and verified all field measurements, field constructiOtiatrtiectias�checkedmaterials catalog numbers and similar data, or will do so, and and coordinated each sample with the requirements of the work and of the contract documents. e. Where specifications require manufacturer's printed installation direction, submit duplicate copies of such directions with samples submitted for approv< f. Cost of samples, together with transportation, delivery, and any other costs shall be borne by Contractor. No manufacturer will be approved for any materials to be furnished under g' the contract unless he is of g re good utation, has ample plant capacity, P and has successfully produced similar products. h. Do not order materials until receipt of written approval of samples. If samples show variations from contract requirements because of standard shop practice or for any other reason, make specific mention of such varia- tions in submittal letter. Sample approval will be general. It shall not relieve the Contractor of responsibility for accuotheracy of such samflthencon- for proper fitting, construction of work, tract documents, and not indicated by the submittal of the sample. Sample approval shall not be construed, as approving departures from contract requirements unless specifically noted to that effect in writin by the Architect. Architect will review and approve samples with promptness so as to cause no delay, but only for conformance with a design concept of a projectand oval of the information given in the contract documents. ofassembly item separate items shall not indicate approval Y in functions. Satisfactory samples will be so marked together with the date of approval and returned to the Contractor. ,amples which are not approved shall be returned to the Contractor with Sthe h changes and changes shallonotcbeoconsideeed made by the originator clearly marked as an extra. The Contractor shall re -submit the samples until they are approved. i. j- k. The samples shall: (1) Be numbered consecutively. (2) Be dated. (3) Have project name. (4) Have submitting party's name. (5) Show kinds of materials and finishes. REVISED: laniiary 1. 1982 THE CHURCH OF JESUS C:iRIST OF LATTER-DAY SALNTS CHURCH EDUCATIONAL SYSTE.`I CENERAL CONDITIONS CC/8 (6) Have the manufacturer's identification number. 1. One approved copy of all samples. shall be on file with the Contractor shall furnish as many other samples as are requirOwner. der field to a The expedite the wor'{, in the SECTION 9 -- MANUFACTURER'S DIRECTIONS AND GUARANTEES a• All manufactured items, articles, materials, and equipment shall installed; connected, erected used, cleaned, and conditioned as directed by the manufacturers, unless therein specified to the contrar b • At the termination y' i.aation of the work, the Contractor shall submit three complete sets bound in the best grade, hard -backed binder of all operating tenance instructions presenting full details for care and maintenance all visible surfaces and all mechanical and electrical equipment g and main The sets shall include the following information. nance of installed (1) Complete description of items including catalog numbers. (2) Complete parts list for each item. (3) Name and address of local supplier. (4) Name and address of manufacturer. (3) Complete operating instructions. (6) Complete maintenance instructions. c• In the case of guarantees or warranties ywrkpereoreed by Contractor or an q Contractor shallSsecureracto suchr' where or warranty Properly addressed these warranty shall be delivered toed in favor of guar�r�ce Of the particular ' Owner. Copies of work. Such delivery s presentative ilpon completion ry shall be a condition of final payre:uc d. Delivery of guarantees or warranties shall not relieve Contractor from any obligation assumed under any other provisions of e• Nothing herein intends or implies the Contract. by guarantees and/or warranties shall apply to work abused or neglected Y Owner. f• Temporary or trial usage b devices, machine g y Owner of any mechanical and/or electrical under this contract apparatus, equipment or other work or materials supplied shall not be contract, prior rd as evO written acceptance b Owner's acceptancerof sameesentative THE CHURCH OF JESUS CH_ REVISED' RIST OF LATTER-DAY SAINTS CHURCH EDUCATIONAL SYSTa January 1, 1982 GENERAL CONDITIONS GC/9 SECTION 10 COORDINATION OF WORK d of the Contract, the Contractor Structuralaworkre hwithethose a. Before cifi- awar eneral and and ventilation, and air conditioning, cations and the drawings fheatingg report the same to the for electrical, plumbing, if there are any discrepancies between them shall rep resentative, and obtain from him written instructions for owner's Rec necessary changes. SECTION lI EWIINE SITE examine the site and the areas adjacent to the site shall exam a. The Contractor structures, utilities and other He shall repair any of these which are and become familiar with all existing and material as facilities that are to remain• by his operation to the st a don sfor comparable pwork. damaged set forth in the detailed specific SECTION 12 EASEME NTS PERMITS AND CERTIFICATES nature for the prosecution of the _^erases a, permits and licenses of a temporary aid°f�by the Contractor. pelin'existing work shall is for permanent secured en structures or permanent changesaid for by the and easements for p the proper Contractor and p facilities shall be secured b Owner, unless otherwise specified.ion that may be required b. Contractor shall secure all certificates of inspect having jurisdiction over the work. He shall deliver same t0 by authorities h lesion of the work. Architect upon comp required to secure a building permit as required by who has the authority to grant such a permit, and shall C. The Contractorbwoa�l be req the governing be paid for by the Owner. or Subcontractor shall secure such permits and to their may required by the governing d. The Mechanical Contractor work as be reqSuch permits and inspections pertaining require same. body having such authority to issue or aid for by the Owner. inspections are to be p permits and the governing work as may be required by its and The Electrical Contractor or Subcontractor shall secure suchpermits e' pertaining to the Such p inspections p to issue or require same. body having such authority the Owner. inspections are to be paid for by vation and Earth Moving Contractor iningstoctheirctor worksasll f. The Exca inspections pert to issue secure such permits and insp body having such authorityt for may be required by the governing ections are to be p aidor require same. Such permits and insp by the Owner. THE CHURCH OF JESUS CHRIST OF LATTER-DAY SAINTS CHURCH EDUCATIONAL SYSTD1 GZNERAL CONDITIONS REVISED: iQR2 GC/10 a. M C. M e. The Owner shall establish base lines and vbench about the project. From this basic marker at convenient point: work (including data the Contractor shall lay out the other facludin es) as ssho"m uonsthetilits, sidewalks, roads, grading and a rrors or inconsistencies indrawingsor as directed. g g to the Owner's Representativenand levels, or dimensions shall�beereported is commenced. proper adjustments thereof made before w Structure locations and elevations shall be established b but must be verified by the Owners Representative in wri ceeding with construction. Y the Contractor ting before pro - Levels shall be established on each floor by the Contractor others. Each Subcontractor or trade shall verify all dimensions for the use of grades, and lines as such may affect ehis lwork, and evels as well lors any errors or discrepancies therein to the Owner's Representative reconcile the same before work continues. p ive who will As the work progresses, the Contractor shall lay out on the floors, the exact locations of allpartitionsforms, or rough Other Contractors and all trades providing wrkkwhichlids to all trades. connection with walls and/or partitions shall check such locations and immediately notifythe P to be placed in or c,'�anges necessa Owner's Representative of any conflicts in or='t to accommodate services, utility lines or equipment required by the contract documents. to make such check and give notice as Coutl nedrabove shalls and sberequired failing assume any costs resulting from their failure to do so, a required to All such work shall be done by personnel properly trained a the type of work to be done. and licensed �n SECTION 14 CLARIFICATION OF CONTRACT LIMIT LINE Should utility extensions noted as contract limit lines then it is ex Peas lof this contract extend beyond the done in a minimum area alon P Y understood that this work shall be operations required to install hthe llines ne dand lforrthas aea thall be confined to the shall not be used for storage of materials, parking, or an Contractor shall effect these extensions and ark complete Purpose only. The area thereto so that Y other use. The the areas may be returned to their normal useobllastrapidl )rase Possible. SECTION 15 PE, ;NFNT UTILITIES The utilities serving the structure are attached to the various fur- nished by others. The Owner shall sous services elevations of sewers, water lines electrical to the Contractor the locations and where connections are electrical s to be made. services, etc., at the points REVISED: January 1, 1982 THE CHURCH OF JESUS CHRIST OF LATTER-DAY SAINTS CHURCH EDUCATIONAL SYSTEM! GENERAL CONDITIONS GC/ll AS BUILT DRAWINGS AND ON SITE CONTRACT DOCUMENTS SECTION 16 - of all drawings, roved shop drawings, change orders and other a. Contractor shall maintainatthe site for Owner one cop record all changes specifications, addenda, pp modifications, in good condition and order and marked to in construction. These shall be available to Architect and made during owner's Representative. ctor ne set b. To facilitate the above, the Owner will furnishthe this acontracth oContrac- of ozalid prints of all drawings which areoaodP condition in his field office. for shall maintain this set at prints in g el u on the installation of any work in locations or in a manner Immediat Y P on the drawings, Cont=actor shall indicate such schanuchges other than shown iven to permanent objectsand/or grids. on the drawings. Dimension shall be g building columns, buildings, sidewalks, curbs and driveways, s in a neat, legible man - to complete the record drawing to Architect, c. Whenever necessary to a competent draftsman satisfactory ner, Contractor shall employ es on the prints. to make new drawings or to indicate Chang tractor shall deliver the d. On or before the date of final inspection, Con completingin corrected and completed prints to Architect ctsto aid himect w.1 not relieve s. Delivery of the p required inform Contractor of the responsation that ibility "as -built" drawing of furnishing rints. Delivery of the prints must be made before may be omitted from the p percentage. payment of the final retained p SECTIO N 17 -- STATUS AND RESPONSIBILITY OF Oy�NER'S REPRESE`iTATIVE ion of ive shall have general supervision and direct a. The Owner's Representat agent of the Owner on the site, and shall have the the work. He is the ag advisory and consultive services of the Architect available at all tunes. of enforcing the performance of the Con- b. He shall have the responsibilty roper and shall permit no changes in the conditions thereof without p tract Changes in the Work. procedure as outlined in Section 22, g given to the or other information will be g agent except c. All instructions, directions,in Section 7. oritractor by the owner 's Repchitect'SvStatus land uDecisions, C prchite as outlined in Section 18, Samples. Shop Drawings, and Section 8, d, In general, the Queer's Representative shall have the following responsi- bilities: work whenever such stoppage He shall have the authority to stop the (1) to insure the proper execution of the Contract - may may be necessary of any work that is being improperly This shall include the stoppageincom etent workman be taken off installed and he may demand that any P the job and another man substituted. THE CHURCH OF JESUS CHRIST OF LATTER-DAY SAINTS CHURCH EDUCATIONAL SYSTEM GENERAL CONDITIONS REVISED: �Q� GC/12 (Z) He shall serve as interpreter of the conditions of the outlined v Section of or inte tpretations b Contract su Architect's Status and y the Architect (3) He shall serve Decisions, P to enforce as of the °Wet performance of the decision or aithful Performance subject Contract with interpretation by the Architect as 18, Architect' J t0 a review of his s Status and Decisions. Outlined in Section SECTION 18 -- ARCHITECT S STATUS AND DECISIONS a. The Architect's throw tsupervisory and administrative authorit contractdocu,mentss Representative, except as Otherwise Y shall be exer ce en.�ise provided in the b• In his capacity as author of interpreter of the contract documents As such, the conditions of the Contract and the Architect shall he shall side neither with the 0 use his powers judge of its performance under the Contract to `'meT nor the Contractor c_ enforce its faithful erf but sha. In general, the Architect's P ormance by t responsibilities shall include the following,., (l) Approval of all si+op drawings and samples. (Z) Serve as interpreter of the conditions of the contract documents in the event or decisions ofathethe Contractor takes exception Owner's Representative.to interpretations d• All the Architect's decisions are e subJ e. If the ct to arbitration. Architect fails to render a ties have presented decision within ten days If the Architect ed their either party may after the par - initiated decision after arbitrationthroceed en �dsarbitratior, such decision may or interrupt such Y be entered as evidence but shall not haveb tlirb the parties Proceedings except w been concex�ed, P here such decision is acceptable to f- Architect will not be responsibile for techniques, sequences or construction means programs in connection with Work °r for safet methods, for failure of the Y precautions and employeesContractor, ' and he will not be responsible ents to carry out the Work sin caccordance with material o Documents. supplier or their the Contract g• Architect will not be responsible or liable for the Supplier or an ' or any Subcontractor, acts or omissions of the Contractor performing an any their agents or employees; or anor, any Material Y the work. y other persons REVISED: January 1, 1982 THE CHURCH OF JESUS CHRIST OF LATTER-DAY SAINTS CHURCH EDUCATIOVAL SYSTE.%f GENERAL CONDITIONS GC113 impose upon the contained in these contract Documents d andsshallhall not createof h, Nothing duties or obligation arty beneficiary Architect any contractual, third p firm against the Architect any other person, other rights in favor of the Contractor or any or organization. RELATIONS OF CONTRACTOR AND SUBCONTRACTOR SECTION 19 - Subcontractor agrees to bind every Subcontractor and every as a. The Contractor terms of all the contract docmentofathisrsection, agrees to be bound by theterms the following provisionsroved in. applicable to this work, to the contrary in a subcontract aPP unless specifically writing by the Owner, b. The Subcontractor agrees: e Contractor by the terms °f Saandll tresponsibilihe contract toe's (1) To be bound to the obligations ments and to assume dtoward entsh assumes toward the owner, that he, by those applications for payment in such reasonable he Contractor to apply for payment as covered in (2) To submit � to enable Contractor aPP time the contract documents. Res; claims for extras, for extensions of time and oain (3) To make all clai to the Contractor in the manner provided the Owner, for delays or otherwise, the Contractor uponweek. me for making claims for extra cost is one the General Conditions for like claims y except that the The Contractor agrees: C. all the obligations that the Owner (1) To be bound to the Subcontractor by d redress he Contractor under the contract documents and by all the assumes to t to the Contractor provisions thereof affording remedies an eF from the Owner- progress Estimat on the payment of Monthly To pay the Subcontractor, of values described 1ntheeSubcontractorGeneral 1`lc (Z) account of if issued under the schedule the amount allowed to the Contractor on work to the extent of the Subcontractor's interest therein. THE CHURCH OF JESUS CHRIST OF LATTER-DAY SAINTS CHURCH EDUCATIONAL SYSTE:" GENERAL CONDITIONS REVISED: GC/14 January 1, 1982 (3) To pay the Subcontractor if issued otherwise than upon the payment of :. shall be as in (2) so that Ionthly Progress Esci as large in proportion to the value all as the total [yes his total p work done by amount certified alue of the work done b ham, w• CO the Contractor is to Y hi within 5 days of receipt of a the value of (4) To Pay the Subcontractor payment from Owner. Contract documents or tO such an extent as may earlier or larger the subcontract, if either of be provided by the ger payments than the above. of these Provided ; (5) TO pay the, Subcontractor on d as executed and fixed errand for his work or materials as far time the certificate should less the fails retained percentage, at the to issue it for an issue, even though the y cause not the fault of proper authority (11 To pay the Subcontractor the Subcontractor. received by him a just share of an the Contractor. y fire insurance money (�) To make no demand for es o liquidated dams '• sum in excess _ contract. of such amount as may be s Penaldelay for dela pecificall , in any Y named in the sub - That no claim for Con- tractor Cl the service rendered or materials fu thereof t Subcontractor shall be valid unless writtenished bno given by the Y the Con- o the first ten days of the calendaramonthctor tSbcontractor duritice originated.ng the following that in which the clai.•a (9) To give the Subcontractor evidence is any arbitrationninvolvOpporing hi to be resent and to submit ing his rights (10) To name as arbitrator the General Conditions under arbitration the sole P nominated proceedings ub provided , cause of dispute isethen sibilities bf the Y the Subcontractor, if Other Subcontractor• irk' materials, rights or respon- Subcontractor jointl or if °f the Subcontractor and any upon whom they agree. V, to name as such arbitrator [he person (llj The Contractor.and Subcontractor agree g e that. a• In the matter of arbitration Procedure shall be g 'tohtho„eeir lghts, obligations documents. anal° ous and all ^ set forth in the contract b• Nothing in this section shall create an °f the Owner to Pay or see to the contractor. Y obligation on the part Payment of any sums to any sub - THE CHURCH OF JESUS CHRIST REVISED; OF LATTc'R-DAY SAZ—ZS January 1, 1982 CHURCH EDUCATIONAL SYSTlli GENERAL CONDITIONS GC/15 - C. Contractor, other Contractors, if any, and all Subcontractors shall work and cooperate with$aForeh 0tlinscer Lllatiun,lcheying wwill ork whicli may affect the other's work.in make proper provision to o=°gdbcontraccorccausedLbychisgneglect the work of a Contractor to do so shall be made by him at his own e:;pense. SECTION 20 -- CONTRACTOR'S SUPERVISION a. The Contractor sball in writing designate and keep continuously or' and until the project is finally accepted, work, during its progress assistants, all satisfactory competent superintendent and any necessary ncendent shall not be changed to the Owner's Representative. The sup Representative unless except with the written consent of the Owner's Rep the superintendent proves to be unsatde�tactory to the shall Contractor ance to be in his employ• The superinten in his absence and all directions given to him shall be as binding as i iven to the Contractor. important direionsnshallios lbebsocconfinnneded bon writing g to the Contractor. Other directwritten request in each case. ive efficient supervision to the work, using his best b. The Contractor shall g `1 and compare all drawings, stud skill and attention. He shall carefully and other instructions and shall at once report to the specifications reseanderror, inconsistency or omission which he may Owner's Representative any , onsible for their existence or discover, but he shall not be held resp discovery. c. The Contractor shall render his assistance to other mechanics in every can be of service, and such assistance shall way is which his special work art of this Contract. be given promptly and thoroughly as p SECTION 21 -- PAYME.'`7TS TO CONTRACTORS application for payment, Contractor shall submit a. Before making the first arts of to owner's Representative a schedule°atinguthe es ototal sum lOfsthe Contract the work, including quantities, agg g to Subcontractors. Such schedule divided so as to facilitate payments shall be on the form enclosed in these documents entitled monthly Progress Es cimate. The schedule when approved shall be used as a basis for monthly progress payments. b. On proper approval by Owner's Representative of Contractor's Monthly Progress Estimate, which is to be submitted between the first andtenth Owner shall, within ten (10) y day of each calendar month,a to Contractor a sum equal to ninety (90) receipt of such approval, pay previous payment thereon. percent of the amount requested, less any &EVISED January 1, 1982 THE CHURCH OF JESUS CHRIST OF LATTER-DAY SAINTS CHURCH EDUCATIONAL SYS—L i GENERAL CONDITIONS CC/16 . c d. e. f. g- • Upon certification by Owner's Representative th'a[ th fifty (50) percent completed a contract work is under the ontract to that and if Contractor has satisfsctoril c and will pay Contractor onePoinc, Owner will discontinue future Y PerLor„ requested. This roc hundred (100) percent of the retencior has not been Inca fifty (50) Percent does not include subsequent amoun incorporated into the work. material on hand ;.;hi Contractor's Monthly Progress Estimate shall show the Subcontractor and such requests shall be available in amounts due to Office for examination b each also include Y Subcontractors. Contractor'sa application Rtion shall vouchers showing, if required by Owner's Representative receipts shall Subcontractors. his payments for materials and labor including or other including payments t In addition, Owner shall include in an equal to but not exceedingY such monthly Of materials delivered totheIIecy (90) percent of thePscixna, an amount ing since site, but not estimated value such stored a last payment. However yet incorporated materials 2 no such into the built and Proof of ade uate until Owner is furnishedby Con will be made for Payment b q Protection of Y Contractor with invoices Y Owner will not relieve Contractoreofathe r�sPonsib' ri continued insurance coverage as required in the co the weatIty Such from the responsibili ility of ty of protectingcontract documents, nor material against damage or [heft. Upon Contractor's receipt of each such monthly am five (5) days thereafter Contractor on pay to each Subcontractorthe' he shall within ' account of such Subcontractor's word Subcontractoramount s. interest therein. to the extent to of the Full and final days of the the fPayment of the contract sum Payment of all of shall be made within thirt ollowing requirements: (I) All requirements of the contract documents ha those listed in this paragraph ve been made including , (g) (2) Payment of all labor and material bills and re waivers and/or releases of lien fr mechanics receipt of all final lien , and suppliers. °m all Subcontractors, macerialmen, (3) Owner's acceptance of the Project under the following conditions: in writing, which shall be given Upon read receipt Of written notice from Y for final inspection Contractor that the facility is shall make such inspection.ana acceptance �f the final �inspectionOerevealsative any items of work have not been tom Contract, Owner's Representative completed in accordance that a written list thereof, shall promptly with the items , and, u p Y furnish to Contractor , another inspection up -on completion of those deficient shall be made by the Owner's Representative. REVISED: January 1, 1982 THE CHURCH OF JESUS CHRIST OF LATTER-DAY SALYTS CHURCH EDUCATIOYAL SYST:1 CORAL CONDITIONS CC/17 le under the When Owner's Representative finds the facility ed, ownereshallbpromptly furnish Contract and the Contract fully performed, to Contractor a final certificate stating istaccepted byhat the kovided far itr in the Contract has been complete and 4 Receipt by Owner of the surety's written consent for such final payment( > to be made. h. No payment made to the Contractor, or partial or entire use or occupancy of the work by the Owner, shall be an acceptance of any WOand acrk or cettancesof t the owner, in accordance with the contract documents. The making the final payment shall constitute a waiver s, all underr they terms of Section other than those arising from unsettled liens, appearing 9, Manufacturer's Directions and Guarantees, from fault, work en after final payment or from requirements of the contra�adeoa dstillana of all claims by the Contractor, except those previously unsettled. SECTION 22 -- CHANGES IN TIC WORK the Contract, may order extra work or make a. The Owner without irrvalidatingo or deducting from the work, the Contract s= changes by altering, addingder being adjusted accordingly. All such work shall be executed xecaim tedor extensioneof n ditions of the original Contract except where anyng time caused thereby shall be adjustedd aatAthe tiT SUCHme of o ITeSiHALLsBEhCOhC'..Ue• IF NO EXTRA TIME IS C AIME D AND ALLOWED INVOLVED. SIVELY pRESUME, THAT NO o changes from the plans and specifications shall be made unless authorized b. N Representative. Any changes made by the Contrac- in writing by the Owner's tor without such authorization are ebt therC�ontractor atshis asole expense. details shown in the contract documentsY Contractor shall not be entitled to any payment for extra work performed in c• provided for herein, unless such work and the pay - connection with the work p resen- ment for same shall have been authorized in writing by the owner's Rep tative before it is performed. d. All such changes, additions or deductions, shall be invoiced monthly. ge shall be determined as follows. e. Value of such extra work or chan (1) By estimate and acceptance in 1mmD sum: REVISED January 1, 1982 THE CHURCH OF JESUS C;?RIST OF LATTER-DAY SAINTS CHURCH EDUCATIONAL SYSTEM GE MRAL CONDITIONS GC/18 a. The cost of any change, addition or deduction, shall be determined on a net field cost basis which shall include all direct labor, payroll insurance and taxes, materials, equipment rental as in paragraph three (3) below insurance and an in or approved off -site expense incurred in connection ewith rsuchectochanF_ addition or deduction. It shall not include the cost of supervision at or away from the site general management, home office expense, etc. general overhead, coo rdinatic nor profit. b. The net field cost shall be determined following the re detailed itemized estimates of the cost of such change, addition of deduction, one by the Contractor, and one by the Owners Re r tative on or p esen- .following which the cost value shall be mutually agreed to. C. Equipment Rental; the value Re Equipment rental rates used in connection with any change, addition, or deduction shall, in lieu of other demonstrated basis, and is any event be not more than 75y the current edition of the Associated Equipment Dealer's schedule. . of This price shall include all overhead on and maintenance. There shall be no additives' fuel, lubrication equipment rental. percentages allowed on d. Additive Chan es: Each Subcontractor or General Contractor actually performs work shall be allowed 5% to cover all overhead and 10% .for profit on the net field costs of such changes, exc equipment rental. If the Subcontractor is a ludiag other Subcontractor, or Contractor Subcontractor to any or Contractor will be allowed 7 � then the latter Subcontractor Subcontractor's total cost excludingcover all overhead on former equipment rental. e. Deductive Changes: Deductive changes shall be determined on a field cost. net (2) �Y cost plus fined addition or deductionrcenrages: Should the nature of such change, Of the preclude in advance an accurate determination probable net field cost, the Contractor shall upon authorization of the Owner's Representative P written maintaining accurate records of the field costthereof with the work, With this Section 22, sub -section e. rdance shall be accom All invoices for �changes in oin work and equipment Panied by detailed supporting data on labor, q pment and daily time cards of workmen arid -equipment maper material., daily by the Owners Representative. be as specified in this Section. The additive approved percentages shall. (3) Emergencies: In case of an the safety of the structure orergency endangering life or threatening without waiting for specific authorof izationgfromPArchitecttr Own may, Representative, act at his Compensation shall be alloweod Contractornfor such emergency or Owner's amount to be determined between Contractor to guard life or property. Representative b g ncy work, the y agreement. Architect .and Owner's REVISED: January 1, 1982 THE CHURCH OF JESUS CHRIST OF LATTER-DAY SAL14TS .CHURCH EDUCATIONAL SYST-i GErERAL CONDITIONS GC119 SECTION 23 --CASH ALLOWANCES Contractor shall include in the contract sum all allowances stated in the contract documents. These allowances shall cover the net cost of the mate- rials and equipment delivered and unloaded at the site, and installation costs, payroll, insurance, and taxes. Contractor's handling costs on the � profit, site, overhead rofit and other expenses contemplated for the original allowance shall be included in the contract scan and not in the allowance. Contractor shall cause the work covered by these allowances tobut be peertformed ill for such amounts and by such ons as ainstrwhomect may he makes1aereasonable objection. not be required to employ persons against If the cost, when determined, is more than or less than the allowance, the contract scam shall be adjusted accordingly by change orer installation hick will include additional handling costs on the site, profit, and other expenses resulting to Contractor from any increase over the original allowance. SECTION 24 -- DAMAGES a. If either party to this Contract shall suffer in any manner because of any wrongful act of neglect of the other party or of anyone employed Y him then he shall be reimbursed by the other party for such damage, including arty agreed liquidated damages for failure to complete by the specified completion date. b. Claims under this clause shall be made in writing to the party liable within a reasonable time at the first observance of such damage and not: later than the time of final payment, except as expressly stipulated otherwise in the case of faulty work or materials. SECTION 25 C1,AIMS FOR EXTRA COST if the Contractor claims that any instructions by drawings or otherwise involve extra cost under this Contract, he shall give the Owner's Representative written notice thereof within seven days after the receipt of such instructions, and in any event before proceeding to execute the work, except in emergency endanger- ing life or property, and the procedure shall be valid ten so be as provided for changes in the work. No such claim shall SECTION 26 -- DEDUCTIONS FOR UNCORRECTQ WORK If the Owner deems it expedient to correct work injured or done not in accord- ance with the contract documents, an equitable deduction shall be made from the contract sum, said deduction to consist of the difference in value plus a fair allowance for damage. THE CHURCH OF JESUS CHRIST OF LATTER-DAY SAINTS ry CHURCH EDUCATIONAL SYSTEI.S GENERAL, CONDITIONS REVISED GC/20 - January 1, 1932 SECTION 27 -- SEPARATE CONTRACTS a. Owner reserves the right to let other contracts in connection with this work. Contractor shall afford such other Contractors reasonable opportun- ity for introduction and storage of their materials and the execution of their work, and shall properly connect and coordinate his work with theirs. b. If any part of Contractor's work is dependent for proper execution or re- sult upon work done under a separate contract, Contractor shall inspect and promptly report to Owner's Representative any defects in such separate contract work which preclude his own proper execution. Contractor's fail- ure to inspect and report such conditions shall constitute an acceptance of other Contractor's work as fit and proper for reception of his work, except as to defects which may develop in other Contractor's work after execution of his work. c. Should Contractor sustain any damage through any act or omission of any other Contractor having a contract with Owner, Contractor shall have no claim against Owner for such damage, but shall have a right of action against the other Contractor to recover the damages sustained by reason of the acts or omissions of such Contractor. SECTION 28 -- WORK BY OTHERS No claim for damages will be asserted by Contractor against Owner for delays caused by other Contractors to whom work may have been awarded hereunder by the Owner. If Contractor contends or asserts that his work is being held up by other Contractors in completing their work on a timely and orderly basis, Contractor will not be allowed any extra time for completing his work hereunder unless these delays are brought to the attention of the Owner's Representative by notice in writing, which notice shall identify the name of the Contractor or Contractors whose work is interfering with performance hereunder and shall describe the nature of the interference. Upon receipt of said notice, the Olk'ner and the Contractor shall endeavor to agree as to whether extra time should be allowed on account of such interference or delays, and in the event they cannot agree, the extra time to be allowed, if any, shall be.determined by arbitration; provided, however, that the arbiter will not award, in any event, any extra time for delays occuring prior to the time that Contractor hereunder has served written notice on the Owner of the existence of such delay and the cause there- of. No such extension of such delay and the cause thereof occuring more than seven (7) days before claim therefore is made in writing to the Owner. In the case of a continuing cause of delay, only one claim is necessary. SECTION 29 -- ONNER'S WITHHOLDING OF PAYMENTS a. Payments may be witheld from Contractor by Owner if Owner's Representative withholds a Monthly Progress Estimate or nullifies in whole or in part a previously issued Monthly Progress Estimate based on subsequently discovered evidence, in order to protect Owner from loss due to: (1) Defective work not remedied. (2) Liens or claims filed or reasonable evidence of probable filin REVISED: January 1, 1982 8• THE CHURCH OF JESUS CHRIST OF LATTER-DAY SAINTS CHURCH'EDUCATIONAL SYSTF_\1 GENERAL CONDITIONS rrI'i (3) Contractor's failure to promptly pay Subcontractors for labor and materials accepted by the Contractor. (4) Architect's or Owner's Representative's reasonable doubt the project can be completed for the unpaid balance of the contract sum. (5) Damage to another Contractor. b. Upon satisfactory removal of any such grounds, payments so withheld will be made. SECTION 30 -- OWNER'S RIGHT TO DO WORK If Contractor should neglect to prosecute work properly or fail to perform any provision of the contract documents, Owner, upon three (3) days' written notice to Contractor, may take such steps as are reasonably necessary to have the required work done including but. not limited to hiring third parties to complete such work, and may deduct the cost thereof from the sums due Contractor. This remedy shall in no way prejudice other remedies available to Owner under this contract or at law nor be construed to be an election among such remedies. SECTION 31 -- OWNER'S RIGHT TO TERMINATE CONTRACT If the Contractor should be adjudged a bankrupt, or if he should make a general assignment for the benefit of his creditors, or if a receiver should be appointed on account of his insolvency, or if he should persistently or repeatedly refuse or should fail, except in cases of which extension of time is provided, to supply enough properly skilled worl=en or proper materials, or if he should fail to make prompt payment to subcontractors or for materials or labor, or persistently disregard laws or ordinances, or otherwise be guilty of a substan- tial violation of any provision of the Contract, then the Owner may, without prejudice to any other right or remedy and after giving the Contractor seven (7) days written notice, terminate the employment of the Contractor and take possession of the premises and of all the materials, tools, and appliances, thereon and finish the'worc by whatever method he may deem expedient. In such case the Contractor shall not be entitled to receive any further payment until work is finished. If the unpaid balance of the contract sum shall exceed the expense of finishing the work including compensation for additional managerial and administrative services and architectural services, such excess shall be paid to the Contractor. If such expense shall exceed such unpaid balance, the Contractor shall pay the difference to the Owner. REVISED: January 1, 1982 THE CHURCH OF JESUS CH1RIST OF LATTER-DAY SAINTS CHURCH EDUCATIONAL SYSTMH GENERAL CONDITIONS GC/22 . a ch he work Coi�Cl pR' S RI Co °rity shall neracto , fora be sto Tp STpp WO Contrac r or Period Peed and RK pR TE by the for w. anY. one °f three er aay °rd h'MIN,gTF Cp �rritt Os''ner, in =h . re w. (3) Mo....er of an NTRApZ. from n notice RePresen�' (30) days th ham, , throe y court' o Plant he der tO the tative� Ys any s r if the gh no act r other Or R'ateriaayment �ner� sto en the aCO warded Or'rner shouia fault P SFCTI is -foand reasala work'° a or te�iaa or ayrbu trato fall o cc ON ble cut to Pon r a a' A11 3 rT TIp prof jt and image y the loss sus racy end ,. steal disbutft N tamed Apo in 1 be su ' claims of gAZ, ° f the y tted to °r question., the chitects ran Fo rbitratio sub3ect entered vailiag a this °f Arb n in accord ° arbi tra dicti in th rbitra agreeme itration ance tion and be a °a° It is h2ghest tiOn law nt shall b prOcedur vl th Provi er the have c,Bdit mute court ,and a spec. a of the sions3 CC ve again son Pre ally agreed the .Judgment ificell Americ then b. The Co. tr s the o Ceernt to anY that th d'e� tare or Sawa=d re eable I�n� ProceedingcCoor hall not right Of legal actin the arrbi hang ma C. No Pt ca n tra J - wi tics Oft by agre . use a delay that Gicher°rs sha an appeal a A rch the errand r ant nth the the wok ParrY r sh thin ten from the and the rbi ration he der' r during any ar ej�Pre be madel0) days ochitect�er'sP ea dispute hitratiOn d. The ssll' stiP 2a en a r asorecejP=sion� she dive, s Ill be tiled aw arbi tr din the nable time in anY case th the Arb . in Wri Li ma.ic= to the if the cOntrac �e of final Pa he demad re si altrlI be is ng inside ty of them Party who Y de® Yment, e tor, arb , made re to to th shall de content. the case xcept as oche Lion shall f ixa ause Pr®seed - err PrOPer n is susta requireitr"'ise dad s their theym gands i to c fined arboth hl asses °wa c may alsOmPenso f the amPensate' such are a authori2 S Par ies. s the cost s an =on cWQ a dam ages f ion wasze o d the t - as they or ato £CTIpN 34 d char8es sf °the i e delay. emended wi and e:c- - se e S . the ProceeProvided b arbitrat t OsGttre ke or 1 scent ao �� L4CX0tr dings upon e 8 ement s r and its ckOuts� a esPonsib . °r emPl2. °Yees,thh r On fiche for Part anY Of ses ever' delays In!Cntont for caused to Con compactor da . sm emPloyeas tOr by 3n �' y be cons ed, o 1' 198 2 TFg ®FCFi pF J CSC R-DAY SA I US CXRIST GF��T U�C}�ATTpY 'S GC127 CO..0 TTT._� Sdcz-,, work by attl of the arate t VSZpN pF ZEE the 4rogreor by ane work, °r by EX' e in loyees' in Ih dab1e DE YS ANC at any t its des ordere J' unaVp1 lay 3 35 delayed = any ° than$ ortati °r by d d for actor be p;,rae'c o ez, or by in transp control, eXtende tati'je the �Ontr ct of the the O�n 1 delay tractor 5 shall be Represen �t or negl e�4loYed bi e, unus'sa the°n capletlon a der s otit= eat 1pcko aoy' useetb t e tipreed u4on by th °£ the 0'ez 1 tag ltie zbitratlon a as may be ag represent = Shall pp = on Y n a ,able pendi 8 scna a t Or aaY COntsactO ing the uses . `'u� Cpnt=actor . that the Oran pontr act�er � I. is being ca o f suc s and Or cDntenn�e uncle= the effect o� h the de lay unles ed in t`'+ Contract erfo� to thate= � v+h se pf de expect abn°r� I£ delaying p . writ dg a mane as tau be norQ,ally that such t is te serve np the delay th of be con it u d eo demOnstr o£ the 1 Weat'ner con' causiag 1 n e tY is ns shal tu=e mat It can he osecution p a Bather c°tLda tf d sever d then O dlel y in i:ato account Ih (�) days e. an a cr �d clued a s a tous has taken more tesenta ive • in to 1 weather t the 'OntY occuZing N"rla=, s Rep necessary ma ,wed that a a=ea. for delay o the c,aiZ is all 1'e dir .7- of shall be man vritln% only one dIa`�ings ,g,t of ucb eaten the eo f L a maa�e e£ delay dates u4o be a wed JOT such draw, Zjp s Zna clay tinuz. g the 1. dem d• before se o£ a con reemen sr for de 2� w s aef ter t ek th a O= ag no cla 1 tIo (_ asonabl SO schedulIade th a aSs untlaim be e e • ff h s h= uc ct un r u�I. to £u they' less s h ApC p„tiCL °= Archit contract £ail d not FI��' dl to pLl� ings an �pRR BEFpR.- sentatlVe t° cOnf shall be replace CpRRECZZO� pF fie=` s cs as £al lity °r a shall prompt d without d GZIpV 36 eonde�ed act dot bY .rLrthe £ ntractp docents f making goo 5E d all wo of the co er4°rate tr trot . �° contact exFense damaged by h ed Or a• p►vy the p OV'is is Vhether es by p rdance adaitipn destroy equi= . from the 4 work in pr shall c retr actors t�oVeBrute Sum Contract is °r Sub and re_ex o Crne'r . ntracto ex4erLS ense t p£ °then a lar- all wOrk al Or 14 �OV such = ZSZ pF JRsys pt1R C�RCl'� S�,I'3Z SYSZ�� pF IX.5EREUr-p:r ,]AL CA�cRAZCpt3DITZpL�s GCV24 b, Xf fi-xed b rac for does maY have wr1tten no not remOve d°es not material re, Zrota such cOnd notice o f Pay expens emOved and OtOner Is Rep Work W . may With add such removal f removal cored at r sentative htn a reas Publfrom is °r Privatenal ten f r� finer is hin ten expense( 0 of COn tra and/or mocha bal and after auctio (10) days Represent days of ctOr° ance or t deduct. n sale Written no ativ and/or e /or E charge say de all cos=ner shall t cc sell suchArchitE SECTION 3� CO f�cit tO Contract, arid p uses sh 11for al p=oc r. a° Neither RR,ECTION OF WORK e2 all recur finalTER relieve Contra PayCtoment nor any FIKAL ACCEPT,VCE b ° S"Ouldhip an f responsib r°vision is E3c'e�ante�thin ots ne develop in llity Ch for fa the Macerct docum re erics Of oae erjo(I) Y and f°rlayear from z�rk due to f erials Or WOr�ans tlon�rs ecludin Coatr`-�t�terlals fo=ate of final material Repres Such reps 8 those in shall reme which a l accepta is and/or shall entative antes steal; be char areas dy an de eB'uc rantee ex. e, or With bear all and, Archit commenced affected b t and eke sts in eYCE C. On �Penses ect s W%Chi y such all �ne=n yc �r.s re fuss there fore° written notice Co (-1 days from rnits see d.ch Contractor orcaY mo eed to haor ve s �h lure t° make do so and Con t�`acrOrr The any shall money due COn ractoenan and charge har ears or re SECTION 38 not apply to work a d/or his Surely cost the reotc Oa LLF'VS Lased or Neither neglected re eShall se l f becomthe e aye Ymen C nor by �''ner. an `4ff1davj any and al QntiI the any Part of flot Ii ens rac ive as he h has t a 1pt and Rearls�g out or tsha I deli 5) Percent Of Receipt kncvled II labor lease of of the C ver to retalne fromPt an Se or and all ob °ntrac the d Perc ., Contra finds Release infor�atiomaterial forligations C. He sh O``a a com ree ractOr ma iVidual sub hall also of thy• which a lie ich sha11 also fur Iete ease for Y, if contra be fug. In add. n co incl nis n4Sy him r receipt anY subco ctor and =shed to itaon, an could be fi Include (bc aremade against Pt in fullntractor ' Jor the 0.ne indiVe led as f- fees omPell d etCOally ntracto=n° 'If shal an furnish a b°d s 1 Supplier PPlier thH Con ral ac�o=2` r a reaSOnaby in dis ha l refund eto reMains iunset°ry to tre h es to fu r, the Ze amount. rging such a lien the all on d afternil to n en including all costs the Pay-mee-T s lact ma and attorney RF VISA . January I, I982 CHLRru CKUI�H -DAy ST ZD CRRST GRAL IlCgTIONAL Y� rr,, G1' i COMn r-,.- _ it as a �°Le act or sublet assign anY �1 the �ntr Contractor itten r10N 39 p,$SIG retract shall ther�nor spat out the P ce o f such assigrrsen to the CO t of the ° hereunder' wi due note .then r written consent es due to hum hhas been given tniest dueeor t hen ed there o in .biting • )r►sent of d has cOrvM ons d as ng O C0:'�LEt10t1 actor .thin the OCCp�ZCY gEF b the Cont on thereof , the feted ar,d ON 40 completed y extensi have been come suc'' oc SEC'L'I has not been d written s Which lit`I • By Quality the work any autho'cu'- l facil completed face fete nor the 1 claim for li a' for there1n' °occuPy and occuPy any rk as being c der s enti le the der elect2ifsOw,me .Slecisarca to pup Cyr fo a comp led by the Contractor in also, n0 Panay thi7OrTma'yk,nnor sh nor shall such °c forex ac a enseine be ng ccuPled the dat'dedamag`o' any extra ethe facilities are before COmplet101n' Contractor the work Whir ccuPy a faciise of items -yetCk 1st' der eamPleting es to ° check Su the arantee 1 t the pier des font=actor a covered by s Sri.s to be e even to the the WOrk t�ja check liWork that may on b. In will 4resencampletion °f on Of replace Contractor is owner and upon The presenredo repair 7 e event the occuPy any Pleted' ce5t the work t havi.ag t° ancy. the desires an event the .,�11 ac e Contractor again. through °cCuP and the t in suc damased °r d stral to time °f c�P . if offer elects , bu d d fete an schedule as to may do s - of items yet list e the Owner -Will far 0�e loll • vered y the check a check b Owner present to Con o f the Work C° of the b reason hereby; (1) on completion fixe res zte� t the work. extra expense y date e. c�Pletion ck fist is p d be acceP 11 be P r to the Put t the the shoul Contractor ility Pr' at the time a amount which they reaching the of the f a 11 agree as t° the the event a reaching ancy the in •�e c Offer Upon t occu4 d Contractor j by expense v and tion• on agree.. er an ' extra arbitra a or u4 ow,,ana prior tO Orr Of said gubtnitted toe extra e:'-Fen forthWith °Ccupy alloyed by reason will be amount of the Owner may agree' the me%aeat as tO thea trati.on ce of an agee the mattes t° . acceptan be to submi le on Shall o f comPlet eo check the facility• i before cotoPe ad thodate t the t bitration if ancy of the shall it operathe ti.es agree is fixed by ar (3) cf utbe hr no � to the el -tent the time exCeB t anted o JDg CIIRZST list is prescannot agree. OF CK S the parties R-DAY �t1AL SYSTF`S OF Cxx E CGVBOITIO.IS RAL GC126 �q) Tj1e 0 caner Shall completed Within the waive I �e allow for flquidate SECI•ION ql _ eel or on �h° fir d by he a:n ges, if t a. BUILDING CODES O f the early ro ct he work and n is work d that he for represen I..4TIONS ccupan Y b add: he and all O is that he he Ordinances II c°mPlian�hers world is familiar Juring sdi``ion over kind e9utire II under 8isl this Jeri all be come (1) famil The latest his work, inc uingove ental °des?chllesshall p rj Conference Ofition Of the g but not I�ithoritY Orregulati (? Build' Unif ted to other ai t e .test edit; Building Officials Building Cod,,,the follow n �3) The `y °n Association of the ►,LiLife Safety a fe Of the Internal (q) Illlams_Steiger ►►Oc tY Code;► Of the Na b. if All local ordinance cuPatlonal Safet tlOnal Fire s i h, any Pro r Observes s • y nd Neal th Act,, o halms vlsio that f I970 lawdoc s• c aes and eel un1ss nor lit on, he and/ e sp c�f know, e s for /Or regulatlo essary changes noti f Icat , nglY changes. ns hay r Y owneZons r, are in hue ly indemif °wed contr Contractr e been effeOuired for s RePresenra rlanc refrom. Y owner ary to shall be led as comPlianc tine SECTICN a2 I against id to s and be c dues a d spon ibi e In he �chLr a• The Arch NSpFCTICNS i tL ,qND TES all Costs and P gvla 1�hany nd ProvwOrk wherevtect nd Owner►s TS nalities b If Ide Proper f cZllis in prepaxatative steal theC077 s for tion 1 Pro at ContiPubllab auth ri ty Ct do cnen ts, 0 such access and g ns s al and times the have access If tOr s °4uir caner►s Pectio Contra to the the date ospectiOng s e the any irk to Representative, n. cloy shall Inspection the by a time specially laws pect ' ins any aut ly ho ly to , ordinances Practice °ns by the PectiOn she horit3,, Other lice of i steel or a , Or a,, but approval le a the or is Represent epr Sll ee cleared than the readiness P for eel, the y him, be °- cons, ce Of su ntative Y the 0471 wnerrs ins c. uncovered rat of the PPIy, I f shall be er►s Re RepresenLactior;. All tests d for exatainaOwner's Re any work she °mptlY made sent.,,.,1Ve. r yehe and and nt ct s' ectlondocums °f a Ion at the cone=a ive ul L b anmust,d u where for Cost of hlch Involvnts, or as kind, not cloy►s exp rase if requ1 eto - r the P tests or es expense may be requestspeclfical Proved tO urPose of Inspect; shall ed IY re u are not be fault PrOying the as ordered be Paid fogy the 0 per eel hereinaf Paid by =he o e= om ,suoh Iteoi borne be-xisterace °f pfaulty IY by a h der • R eSe j to r s °r inspettioCo..... COr re � aI °°r Wod�p� rsons However, R Me, ED. he cost ofaLl f same she stndar s � If 7 Q,4 2 THE C I l be - OF bgli'FR H OF T or 1'ab° they c°sts a Testy as she bled above 1 be made by e, except b the p mi n s als et►tat1 aired y ar materl•testsb f he owner is by the eY • s of pater E g ae r th the directi°n ate�est will be F l Sample Te ring d ee wi ll s furnish al to the s accor an ed in rs• actor Shall rh purposes select ee e r gentati ve the Sip Les ve o= Testing E g n ��ell der' s Represen of materia ess�+ and. £ theZSES S'ZC�'GE atus, rY'e d by 8 aW' ha11 n° unrea �. 43 -- USE 0F Y OrLf e his appa Ls indlcat rive, and LON retractor ahahis wo nta mene sl Re�ateri is t�ctuYe t° be •the operations ati°ns of the ,,dtY► his at to f the s its or dire the presses ermlt any safety , °ns z ins cti sonably enc�be no r load or danser its ve s t� Contractor lght that Wz.11 en er, s Repr en and parking • ,•7alks loaded Vth a ''� force the Cf`'riares , sm°ki g ne with use o f e contractor shall h advertisements , an orderly bered • Shed e ti8ht sto e Se re$ardisi8 signs 'an teZials them wa e=- nth maintain Za and keep d t by we cte + d• prranse toads, eatr3-%% where dir a be damn d drives + on 4=�lseals which above gr°un and for maintain of- mate ra1sed t'neir materials Y=ov'ide and Storage d floors, C. or sheds, f° eds with WOO sto=age °f such Sheds rs for eS. de cto us t- t apace to Si S ed,s and tool ho -es desisnated• sheds + `+tO edge pia 0 e o f to sp s a f • erection of t e ate=ials t Q,ove ma eXt a� cosL to n platf or Confin �tora8 time o with° Ze+ ° g. a egsa�`3 at %w directed, ed by m°ist,s it be nee as and wh =materials affect Should same m° e h• forms I v 1 $red o th aher . om a we is i• Sto=e�c the f= the on for all doss and pro pRO-ey rote-ti inju='1 °h dat'a4� top from c. CIO c_ . CT=oN CF �OR'� ly maintain er gq p,Qpe ' a good a ny c°nt ac tel9 -- 4R0 SECZZC� shall contlnuo,}sl ct the 0 U. shall ozs in the ade4ua _ 1 prOte t=act• a to err 8e 9 ocsments Seas The Cont a damage and swath the C directly d the ,er contract ar traf fic aie a• work from Gonneetiot► . as may a loyees of aW and the d vehiculuatemaud dirt arisingor loss) exce agents °r as Ip�vided by edestrian = vavL ide ad Snow, d dents or r a en prop hal be $ ch a maaaev s free f cQ Water' ad j on �1ed s is area protect 11 be n nta Keep t=a t sC'RRZ5T cula= at .,-he a se sha 1 taws , obs tructi°n CK pF ass'. 5 s sa8e at al or other C'� R-�N 5 �lAL SYS'�- p cks deb=is pE Z,P•' V'jCATIC` ti5 o G�E�! CO�ZZZ.O Gr 12a recauL].`-+•`.• toV. sions �` or take all necessary P 1. ,ble P pre accidents shall with all aP4 Codes to P Properly maintai: The Contractor shall comply Building ect and Prop all b• on the work an al Safety Laws a scent to the Prrogress of the wor,and steal t ees riunicip ad] and P Public, State, and.0 Persons on, about o the conditions en and the P of in]ury as -required by e protectionofrd C such features at all times,ouards for �' h; created by elevator hatchways safeo against the well holes, ele materials, etc. Ke '` necessary morning hoists, materi whose ,Post danger sigTlsotruding nails, a s and falling on p the work, P n as Pr stairw 7- his organiz Lion of the construr enings, member a and posi ding, window oP The Ham s Representative. scaffol responsible of accidents- Hate a the OW`ner shall des1 be the prevention reported to from duty shall ted shall trenches, building be desigTLa backing up of drains person so excavation, water, equipment, enc- Always protect round s -otection: spring water, 8 Provide PIZM c. Water F f=� rain water , other water ; damage, irrigation water or drainage; do sr or sewezSi this protection• orarY sores, to insure construct, maintain nece iloor�free of water - on or Proper exe- d. Temporary Drains eto keep excavation for safety and !; Pumping necessary as necessary Rove snow, ice, etc. Ice: arricades, railways, e• Sny work• ht at b cation and maintain gua d l and at trenches or pets aa7a hts. Pr°`nde road or sidewa f Cuard Li streets, wind, stor's obstructions in Again rain, free to roads- Protection a8 and fixtures cent constant P apparatu. be damage provide materials, work likely to Fr ate Sol as to maintain wozk, cover Weather Q.t end of days work' other reaso g• frost or ea or damage• to Pro protection or from in ed b failure er. ama e: Rey,ove worlt ( Without extra cost to ' canals, In D lace with new for irrigation ditches, ified• replace examine site unless otherwise Water. Careful l three waterways moved on i• Ini anon e uipment is protect and maintain mechanized q O�,mer to stay ° etc. Shrubs: Before A marked by th4„ x 411 posts of Trees and d shrubs that are trees o. all trees icades consistoned around the j• protecti ob site, d and stab shrubs from meChaniyea protected by barT to the J to the groan shru I ect shall be Pfeet in t the trees or 11 x g�� planks• the PrO� least three to Protect attached 2the ground up CO srhlrubs is such a positionosts shall be securely from 4" 7 een the P shall be protected least distance, by dev. i Beta trees is the rotectiVe ,qu pment. the above, all whichever These P danSe' addition to eight feet, nk of the tree. no longer a branches ranch red around the tru there is the bottom sin in place until timbers securely and el the end of the project- maintained be maintains to the trees and shr Ci1URCii OF JESUS CrIRIST TRE •LTER-D�'i S�LI1TS OF �'A �1JCATIOL SYSTr^_= CHURC CO�ITIONS GENE RP•L GC/29 January 1, 1982 SECTION 45 PROTECTION OF LIVES 4ND4LT a' In case of an H safety of life, the ency which threaten instructions Contractore Ow-nerr loss or fr wil l in ' u b• manner. He shall notify the s Representat valleeortoJa t ithoutrtY and/or In order to Owner s the Architect Previous Protect Presentative the Contractor the liv �aediatelln a dlll3e: Accide shall cOmpl es and health of y thereafter Contract Prevention i Y with all his emPloyees tors of n Construction1►Pertinent provisions under the meats imposed by any BInc.ove and any otherta by the cia a the "Manual Asso ���nual ental body such applicable re d General SECT4.ON 46 _ as Federal gulation or re r,' -ISC L State or Municipal. -'`7EOUS ScR �Pa 1, a • Batter VICES gY eac Boards and ge TKE CONTRACTOR ej, established bnch Marks: These as the structure shall be carried Y the Owner rlseSY by the Contractor building3 to the from the b. Tem ora and from floor to re',r- for the Enclosures: floor general Temporary encloser C. l Protection es, barricades, signs Temaorary stairs :he structure shall ue ladders Provided etc needed etc.• idea by the C4- tra c tc 1) The Contractor at a central Positionshall furnish the as directed by t stairway complying for such a stx-ecein every respect wiStructure th s bs antlhe r'�S Representative re n (2) his h the governin Porary wood sta' it is [0 8 afecy code use of all Subco be Provided and The stair, ntracto maintained b finer Re wijl be removed d others Performing the Contractor 's preSentaten in iv y the g work for the e the COntracto °n the structure. (3} All ladders, ramps Permanent stairways are available of rY elevators, scaffolds lahle for the tradesmen, etc. , hoists, ru use, Provided anflr others fcrrequired by the �aYs' derricks Prohibitmaintained the proper execution dual prime, chutes, te.�_ Structure cooperative actionthat Person or eO n °f their work Subcontractor meats 'Shall the multiple Ong the various shall be 1 be theresponsibility usage of ar1Ous wOrkin This shall not Contractor responsib any such facil' g groups On the d, to requir�o s the thee•ovAli lsu h t�of tP randividualltredes t all art-ange_ Tem ora or Toilets; g erring safety code•facilities shall c nfo, il) At the location s 11 Provide approved by theOwner's toilet room, a tempora r3' buildingto aRePresentative and shall be This building shall r tisfac , the Contractor amain the or Y serve removed at the completion of he property of [has a �'°r � s kmen work. Contractor REVZsm : TIM CHURCH January 1, 1982 OF LATTER_ F JESUS CHBISi CHURCH EDUC Y SALI;TS G A.TION,, SYST,n; ��0� COIyDITI0:11S large to permit the installationOf space shall be sufficientlone lavatory which shall be furnishedbe (2) This P urinal, This building may be one water closet, one ubcontractor• but in any case the mechanical S field office, prevented and installed by separate from the tunes will be p contiguous to °r orary heat that fix be so equipped with temp weather. freezing during the winter first- • from clean, neat, and in the toilet rOOm maintain all plumbing The Contractor shall keep the He shall also (3) , class condition at class condition. equipment in first - en his expense for such watt• rovide at shall not be The Contractor shall p �,rork. The Contractor e. Wats to protect the the time when he or his fore necessary during onsible for any loss as may furnish a night watchman be held resp during the required to on or at any time man is present, but the Contractor will Of material or damage done to the p traction period.orises, on or cow temporary work from p teyprar work: Remove f. Removal °f letion of work. before c�P Tem ora Roadways: within and adjacent to the g' temporary roadways (1) der to provide proper access to the structures. Construct and maintain site, in °r adequately sustain and be constructed to adeq endanger existing roadways shall S° as not to (2) Temporary to be carried on them Support all loads underground or surface installations. °r newly constructed office on project site. maintain an his office and shall maintain It Offices: The Contractor shall ma p�rr,er s Representative and the install a telephone in , h. Tem ora The The Contractor shall the Contract. of this telephone for iota completion of equipped with one until final have free and unrestricted use shall be Q Architect shall this job. The telephone installation and all The cos t of The calls in connection centrally located* be paid by the Contractor. large extension gong the telephone shall Incoming calls shall. be charges for the use of station" type. hone shall not be a ��Pay hours. telephone working promptly answered during ements with the proper autrO make all arrang uired by the The Contractor shall mac.) for all utilities I bear all I. Uti1=� city, �ez� The Contractor shall shall ity (state, counts' eriod. the O4mer • This the construction p tance by lines, etc., for Contractor during until final accep meters, ent, costs for these utilities ,fie method of metering body f 1rn. hing maintenance of said utilrova1 of the for of all equipment In clude costs for in responsible the utilization andmmst have the written ape be etc., The Contractor shall t=uction period. connections) to the Contractor. the utility for his use dazing the entire cons all utilities needed THE CHURCH OF JESUS CHRIST OF LATTER -PAY SAIYIS CHURCH EDUCATICNA S SYSTE." GENERAL GC / 31 . �,EVISED January 1, 1982 �l) If utility service the Contractor mayis available from and Paying ' by making pro er the Owner's permanent y for all costs P arrangements with utilities at no time ass , use these permanent the Owner, using any of the�p�e=�responsibilit �a utilities. The Owner ation of s for due to d ge caused b services by the Owner, to interruptionY the Contra regardless or discontinu_ (2) The Contractor of cause. lated rates -for .s said pay the body said the forthe furnishing the utilities (until the final acre the entire construction the sti u- (3) If utility service acceptance of the project by the owner.) Period P rates will apply: is available from y: the Owner, then these established stablished Beat $0.025 per kilowatt $3.50 per million B.Z.U.our j• Temflora Heat: required to The Contractor shall fires or sal perform or protect all of his all salamanders temporary local heating Shall not be used within during cold weather. ll) For work � the buildings, Open performed following the System, heat may placement Purpose of i �e utilized from in the permanent heating providing heat durin the building heating S available from the Owner's g the construction g Plant for All materials a facilities , Providing tze manent and labor as determined b g heat is heatin necessary to Y the Owner. per - expense, g system shall be furnished provide such heat from the per- , including metering, Y the Contractor (2) g,o shall maintain same at his The provision that t in Service. System steal l not relieve heat may Y be supplied from his own work g Y Contractor of the responsibility the erManent Adequate protection against damage from shall be the and freez- to fully Cemporary system outlined maintained at a g weather. Navin emOabove Y means of times either from the g the approvalof the Owner' b other heating facility resulting g devices Otherwise es g from the install RepOesentative. Any dams e Shall Protect his o or a Contractor° 8 to the be made good at the Contractor's rk d cold or freezing failure k. TemDora.expense. g weather Power: �l) Contractor shall Provide electrical (2) Contractor Power to distribution shall provide pigtail and centers only, and around the building, working areas sufficient to for lights for all areas within (a) All Provide _the following intensity: (b) Stairs 3 foot candles landings, ramps 5 foot candles REVISED: January 1, 1982 71M CHURCH OF JESUS CH,gIST OF LATTER-DAY SAL%1TS CHURCH EDUCATIONAL SYSTLI GEIMRAL CONDITIOus r rl I .- (c). Outdoor flood lighting within 3 foot candles contract limit lines (Owner's Representative to approve locations) (d) All areas involving Contractor's 30 foot candles finish work Subcontractors shall provide their (e) in all areas involving 30 foot candles own lighting their finish work SECTION 47 -- CUTTIN G PATCHING AND DIGGING fitting or patching of his work that arts cone together properly and fit a. The Contractor shall do all cutting, other Contractors or Subcontractors may be required to make its several work of it to receive or be received lied by, the contract doctmments for the shown upon, or reasonably �P good after them as the Owner s completed facility, and he shall make g Representative may direct. caused b defective or ill-timed work shall be borne by the party b. Any cost y responsible thereof. digging or otherwise-- tor shall not endanger any work by cutting, S c. The Contractor other l:antractor without the and shall notvaltofrthealter owner's w Representative. written appro the cost of onsib when sresu-`s d. The Contractor shall be held resp otherlContractorsasonably foresee id cutting shall pay said and provided excessive cutting in the work from requirements which could have been re for without undue expense. SECTION 48 -- BONDS Labor and osed in these documents. The Cfnhiscbid', Con shall furnish a 100% Performance Bond and a 100. The C form encl unt of 100% o Material Payment Bond in the bid shall include the cost of both bonds each in the amo price. SECTION 49 -- BUILDING RISK ro ect and all materials and wor'.{ y responsible for the p j writing by Contractor is full resp completed project is accep expense any materials or connected therewith until replace r repair at his own eXP for said Owner. Contractor shall rep work damaged or stolen regardless of whether he has receive payment work or materials from Owner. THE CHURCH OF JESUS CggIST OF LATTER-DAY SAINTS CHURCH EDUCATIONAL SYSTV- Gmg_.�J,. CONDITIONS REVISED: GC/33 January 1, 1982 SECTION 50 -- LIABILITY INSURANCE a• The Contractor shall not commence work under this contract um of all the insurance required hereunder and he has ance has been approved b such insur- Subcontractor to c y the Owner; nor shall the Contractor allow any amraence work on his subcontract until all similar insur- ance required of the Subcontractor has been so obtained and a Approval of the insurance by the Owner shall not relieve liability of the Contractor hereunder. approved. shall be The cost of all suchinsuranecreasece the included is the bid amount. insurance il) Workmen's Compensation and Employer's Liability y Insurance required by (2) Comprehensive General Liability: (a) Bodily Injury $250,000.00 each person $500,000.00 each occurrence $500,000.00 aggregate products complete operations) (including (b) Property Damage (broad form) $300,000.00 each occurrence $300,000.00 aggregate operations $300,000.00 aggregate protective $300,000.00 aggregate products (including o complete perations) $300,000.00 aggregate contractual (3) Comprehensive Automobile Liability, (Owner, Mon -ow ned and Hired Vehicles) (a) Bodily Injury $100,000.00 each person $300,000.00 each occurrence (b) Property Damage $100,000.00 each occurrence (4) Owner's Pro tective Liability (a) Bodily Injury $250,000.00 each person $500,000.00 each occurrence (b) Property Damage $300,000.00 each occurrence $300,000.00 aggregate b• Certificate of Insurance (original and one co Owner Providing coverage ( outlined. copy) shall be furnished can- cellation shall be Thirty -day written notice of to the sion shall be given to the Owner and the Architect can - included in the insurance , and such C. policies and in the certificates roflinsuran Non Liabilit of Owner or or responsibility to an �' hitect:. Owner and Architect assume no liability to cart y person or organization from the failure of Contractor y a sufficient amount or types of insurance coverage. THE CHURCH OF JESUS CHRIST OF LATTER-DAY SAINTS REVZSF;D: CHURCH EDUCATIONAL SYSTal January 1, 1982 GENE R4L-CONDITIONS GC/34 51 BUILDERS RISK INSURANCE OVER ONE MiLLIv� L��- -- ION applicable for projects costing over one million dollars - This section is p�P y. 'i•he policy will The Owner will provide a Builders Risk Insuraand will policinclude the interests be in the full amount of the contract price, of the Contractor and Subcontractors. The insuring, deductible and exclusion clauses are as follows: (1) Insuring Clause: subject to the limitations, exclusion, terms and conditions This policy J respect of occurrences happen- olicy, against all risks of physical hereinafter mentioned, it to insure, in res ing during the period of this p loss of or damage to: (a) property in course of construction, re -construction or repair while at the location of the said consth reinnreferredsto as ion or repair operations (all of which tof Contract or Contracts "the work") which are the subj which will be delivered described in the coverage endorsements; h of the Contract; to the Contractor subsequent to the signing din materials and (b) property of every kind and description (including _ suppliers) owned by the assured and used or to be used proper mayin abea t supp )id including of, incidental to, thework° �1erand�while in located within the co mi uelon, St. Pierre and �1� q Alaska and Hawaii, Canada, or places aforesaid; transit and between any P a art of, or incidental P (c) property of others used or to be used lbe responsible or shall, to the work, for which the assured may be made hereunder, any occurrence for which claim may arising under this prior to have assumed responsibility. Loss, if any, ssured. a h (c) will be adjusted with and paid to the a para gr P W (2) Deductible out of 1 000.00 each and every loss or series of losses arising $ ce t that a deductible of $250.00ts apof ply one occurrence ex P extended coverage each and every loss or series of losses arising renee a� res-pests the perils of fire, lightning, or vandalism and malicious mischlel• (TMP foregoing deductible amounts are the responsibility of the Contractor or SubcontracL��s•� onsibility for damage, if any, caused by earthquake. Owner assumes res P REVISED: 1982 January 1, Tle CHURCH OF JESUS CHRIST OF LATTER-DAY SAI,111 CHURCH EDUCATIONAL SYSTEM GEINERAL CONDITIONS CC/35 ■ (3) Exclusions This policy does not cover: (a) Any loss of use or occupancy howsoever caused; (b) Penalties for non -completion of or delay in completion of Contra or non-compliance with contract conditions; ct (c) Costs of making good faulty or defective worl:manshi construction but this exclusion shall not a 1 p, material or ing from such faulty or defective workmanship Y to damage result - construction; p, material or (d) Loss or damage directly or indirectly caused b a fault, defect, error, or omission in design, plan or specification; (e) Wear, tear, normal u kee or normal P p, inherent vice, latent defect, vermon, making good; (f) Loss or damage directly or indirectly occasioned b �'zrough or in consequence of war, invasion acts of�forePening ene- mies, hostilities, (whether war be declared or not) - rebellion, &n revolution, insurrection, military) civil war, martial law, or confiscation or nationalizaonrorsrequisition� or destruction of or damage to propert b Y Y or under the order of any government or public or local authority, (8) Loss or damage arising directly or indirectly from nuclear re ; nuclear radioactive contamination however such nuclear reaction, - nuclear radiation or radioactive contamination may have been caused reaction, nuclear reaction,ess if a fire arises nuclear radiation, orradior directly indirectly from any loss or damage arising directly from that afire eshall (subject to the provisions of this policy) be covered, excluding however, all loss or damage caused by nuclear reaction, nuclear radiation or radioactive contamination arising directly or indirectly from that fire; ' (h) Loss or damage caused by frost or freezing unless resulting- fr damage occasioned by fire and/or lightning and/or explosion and/ or windstorm and/or hail and/or riot and/or riot attending a strike and/or civil or smoke; commotion and/or aircraft and/or vehicles and/ (i) Automobile except on worksite; W Loss due to disappearance or revealed by inventory shortage alo ne; one; REVISED: January 1, 1982 THE CHURCH OF JESUS CHRIST OF LATTER-DAY SAINTS CHURCH EDUCATIONAL SYSTZv GENERAL, C=ITIO, GC/36 (k) Mechanical breakdown," ising as a consequence or mecna„­­ exclude loss or damage breakdown; (1) Infidelity of the assured s employees; e to material and/or equipment while in the course (m) Loss or damage of ocean marine shipment; ui meet of every description which is not intended Contractor's (n) art of the construction operation insured here- to become a final p under and for which a value has not been declared in the contract price. but not ( limited o) Loss or damage caused by earth movement including to earthquake. SECTION 52 - BUILDERS RISK INSURANCE, UNDER ONE MILLION DOLLARS under one million dollars a. applicable for projects costing This Section is app the interests for their losses to the project described The Owner will reimburse the General Contractor, including civil windstorm, hail, of Contractor andthe perilscofrfire, lightning, vandalism, and herein caused by ail -Taft, vehicle, explosion, riot, Reimbursement adjustments will be made by the Owner commotion, smoke, malicious mischief. a and adjustment provisions of the commercial in accordance with coverag and the Vandalise Fire Insurance policy, Extended Coverage Endorsement,which the and Malicious Mischief Endorsement standard alsotbe subjectnto the following' project is located. Loss adjustments will (1) Deductible Clause: Two Hundred Fifty ($250) Dollars shall be deductedfrom any The sum of T or series of claims arising ny and total sum of all loss or claim, caused by single accident or occurrence or amount isethefresponsibility of one S This deductible all perils covered• the Contractor or Subcontractors- (2) Contractor's E ui went Clause: r consr used fo.ructi of. every description, is the respo', Loss to Contractor's equipment art of this construction project, and not becoming a final p sibility of the Contractor or Subcontractors. (3) Loss Retorting Clause: or:ed reimbursement under this innin section repairsall be inorder All losses requiring prior to the beginning rompt to the Owner's Representative p that det ails of loss can be obtained and verified to Facilitate a loss adjustment. REVISED: 1982 January 1= THE CHURCH OF JESUS CHRIST OF LATTER-DAY SAINTS CHURCH EDUCATIONAL SYSTE:`1 GENERAL CONDITIONS GC/37 SECTION 53 -- HOLD HARMLESS AGREEMENT a• In addition to obtaining insurance coverage as required by the contract ments, Contractor shall indemnify and,save Owner, Architect, their agents and employees harmless from and against an Y, demands, and all liability, ,docu causes of action, or claims thereof, whether well-founded or otherwise, including the cost of defending the same, for bodily injury to any erso whomsoever, (including employees of Owner or Architect) or damage to n property of any person in the course of construction and as a result of the negligence of Contractor, Subcontractors or materialmen, their agents or employees. b. No subcontract shall relieve Contractor of any of his liability or obli- gations under the Contract. Contractor agrees that he is fully responsible to Owner for acts or omissions of his Subcontractors and their. materialmen and of persons either directly or indirectly employed by them. SECTION 54 TAXES The Contractor shall include in his bid the cost of Social Sec urit y' y- ment Compensation, sales, use, and any other taxes as may be required by State the real Municipal, and Federal laws. All taxes and assessments on r perry comprising th; site of this project shall be paid by Owner l property SECTION SS -- WORKMEN Contractor shall at all times enforce strict discipline and good his employees and shall not employ on the project any unfit personrorrayone among not skilled in the work assigned to him. anyone SECTION 56 CONTRACTOR PARKING Contractor personnel Will not be allowed to park on the campus, other than within the contract limit lines or as approved otherwise by the Owner's Rep- resentative. Such parking shall be further limited by the operations under this and other prime Contractors working in the construction area. SECTION S7 -- TRAFFIC CONTROL Adequate traffic control including the use of flagmen shall be provided at locations where equipment regularly enters or crosses campus roads. The method of traffic control and location of flagmen's station shall be as approved by the Owner's Representative. p, SECTION 58 -- INTERNAL COMBUSTION E UIPMENT Internal combustion engines and compressors shall be equipped with mufflers to reduce noise to a minimum. REVISED: January 1, 1982 THE CHURCH OF JESUS CHRIST OF L-kT7ER-DAY SAINTS CHURCH EDUCATIONAL SYSTE.\f GENERAL CONDITIONS GC/38 SECTION 59 MECHANI _AL rulri-ac,., ,,•••••. - pic All self-propelled equipment operated on the project, except Wepanel and andk-uF trucks, sedans, station wagons, and crawler type cranes, pp r shovels draglines, whether moving alone or in combinations, shall be egippedpwiththe equiment moves an independent signal alarm which will sound automatically whenin reverse. The alarm may be contisofrtheintermittent conditions andwcircumstancesbe audible for a distance of 50 feet, irrespective under which the equipment is being operated. Alarms will operate up n initial ntervals o exceed backward movement, and if intermittent, he equipmentaisltra ellingointreverse. three seconds during the entire period the equipment Compliance with these provisions by Subcontractors will be the responsibility of the Contractor. SECTION 60 -- DUST PALLIATION Throughout the entire construction period, the Contractor shall effectively dust- oads used in the operations and involved palliate the working area, unpaved r portions of the site, as may be rtrwatering d to eand hsprinkling e dust to aatlsuch m a frequency palliation shall include intermittent as will satisfactorily allay the dust. SECTION 61 -- REFUSE Refuse barrels shall be provided and papers. The project shall be necessary to keep project clean. SECTION 62 -- FIRE HYDRANTS by the Contractor fu, workmen's lunch boxes kept clean. Remove refuse as often as is The Contractor may use water from the mission of the Owner's Representative. must meet the following conditions: fire hydrants only with the express per - If permission is granted, the Contractor a. Always use a standard hydrant and (Wrenches are available at Pacific spanner wrench, never a pipe wrench. States Cast Iron Pipe Company.) b. Always use a gate valve to regulate hydrant valve should be in the clear the amount of water needed. The open position. Natiar size r c. Never force a coupling thread whicheis not willodamagethebronze2 7 1/2 threads to the inch. Any o d t to see if indeed this is the correct inch, nozzle threading - threads. Check each by ran danf the emergency- event day in order that the d. Always disconnect hose at the en hydrant will be ready for use in e. Always replace the hose nozzle caps after use to prevent the dropping of roc,'s or other -items down the hydrant barrel. THE CHURCH OF JESUS CHRIST OF LATTER-DAY SAINTS CHURCH EDUCATIONAL SYS7E%1 GENERAL CONDITIONS REVISED GC/39- January 1, 1982 SECTION 63 -- GLASS BREAKAGE The Contractor is responsible for glass damaged or broken or putty disturbed during time of construction. Leave glass whole, free from scratches or rattle at time of final acceptance. SECTION 64 -- ELEVATOR MAINTENANCE If the elevators are used during the construction of the building, the Contractor must assume total responsibility and also assume the cost of monthly service to the equipment, by the elevator contractor. This responsibility and all operating costs shall be assumed up to the date of the Owner's acceptance of the facility and the elevators. SECTION 65 -- SUNDAY WORK Work will not be permitted on the project on Sunday except in emergency situations SECTION 66 -- DOMESTIC STEEL No reinforcing, structural or other steel not manufactured in the United States of America shall be used in this project. This applies to the continental United States only. SECTION 67 CLEANING UP a. Contractor shall at all times keep premises and facility free from accumu- lations of waste materials or rubbish caused by his employees, Subcontractors or installation materialmen or workmen, and at completion of work, he shall remove all his rubbish from under and about the facility; all his tools, scaffolding and surplus materials, and shall leave the facility clean and habitable having thoroughly swept all floors, cleaned windows and dusted flat surfaces such as cabinet tops and window sills. b. Prior to and during process of painting and/or varnishing, the area where such work is in progress shall be cleared of all debris, rubbish or building materials which may cause dust, floors shall be swept as required and all Possible steps taken to keep area dust -free. C. In addition to the general cleaning noted above, Contractor shall be respon- sible for his own clean-up and shall either perform or require Subcontractors and materialmen to perform the following special cleaning at the completion Of work: (1) Removal of putty stains from glass. Washing and polishing same inside and outside exercising care not to scratch glass; (2) Removal of marks, stains, fingerprints, other soil, dirt from painted, decorated stained work; REVISED: January 1, 1982 THE CHURCH OF JESUS CHRIST OF L-aTTER-DAY SAINTS CHURCH EDUCATIONAL SYSTEM GENERA_ L CONDITIONS GC/4U (3) Cleaning and polishing woodwork; (4) (5) Removal of spots, Cleaning and polishing hardware. dustdirt, paint and the like; , soil, paint from tile work, washing of same; (6) Cleaning of fixtures, equipment, dust; This shall include removal of stains, removal of stains, paint, dirt, and (7) Removal of temporary floor protection, 1 ets• cleaning floors, and vacuuming of al care doors and o£ exterior, interior metal surfaces, including (g) Cleaning polished finishes, of oils, stains, dust, windows, required to have P of surfaces, leaving them without dirt, and the like. Polishing fingerprints or other blemishes. Pro names or any markings (9) Removal of all comp any trademarks or p that are not intended to remain on any materials and/or equipment permanently installed on the project. d. If any of the above noted cleaning is not done as noted, Owner may have such work done and shall charge to Contractor the cost thereof ;nd may monies due to Contractor. withhold such cost from any built rubbish chute, provide a tightly ate at e. Rubbish chute: Contractor shall p round serving each floor, which shall lead down to angle offset and g points for trucks. Throwing 'rubbish or. debris to the g convenient p prohibited. from the windows, or other parts of the building is SECTION 68 ITE.�SS TO BE flJR`IISHED BY THE OWNER The owner will furnish ground area for storsgallfacilities thefor general vicinity and his Subcontractors. Such snatedebyrea the Owner• The Owner will not be other service or item except those which are expressly of the work, but in areas design required to furnish any designated in the contract documents to be furnished by it. SECTION 69 CONTRACTOR NOT AGENT OF OWNER of a eed that the Contractor is not the agent or employee It is expressly gr ledge f the Owner or in any way attempt to bind the Owner, but that he is an independent contractor. He shall n° p at oint or attempt to pledge the credit o mayelect to .p contract or otherwise. However, the Ownee decided by the owner the owner by agent for such purposes as may right to purchase the Contractor as its es also reserves the rig desire, in which and agreeable to the Contractor. Thef the Own rials s bid, shall be deducted and furnish to the Contractor such in the Contractor's -bids as it may event the cost thereof, as figured from the contract sum - REVISED: January 1, 1982 THE CHURCH OF JESUS CHRIST OF LATTER-DAY SAINTS CHURCH EDUCATIONAL SYSTF-"I GENER.%L CONDITIONS GC/41 • SECTION 70 -- APPOINTMENT OF OWNER'S REPRESENTATIVE The Owner will appoint an Owner's Representative. Said Owner's Representative may be replaced from time to time by another or others appointed by the Owner, in which event the Contractor shall be given written notification of the change. The Contractor is authorized at any and all times to communicate with the Owner's Representative and give any notices, make any requests, and follow the directions Of the Owner's Representative; provided, however, that any directions which constitute a change in the scope of work must be given in writing, SECTION 71 -- CONTRACTOR TO APPOINT AUTHORIZED AGENT AND SUPERINTENDENT The Contractor will appoint an agent and superintendent, and agrees that he will be assigned to the project. The Contractor also agrees that all notices, requests, and instructions given to said agent shall be considered as having been given to the Contractor. SECTION 72 INSPECTION While the Owner expects to have inspectors on the job to inspect the work as .it progresses, it does not obligate itself to do so. It is expressly agreed that the fact that the Owner has inspectors on the job shall not release the Contractor from performing in strict accordance with the Contract, and the fact that any particular work has been inspected shall not be a waiver on the part of the Owner of strict compliance with the Contract. SECTION 73 -- ATTTORNEYS' FEES The Contractor agrees to pay any cost incurred by the Owner in enforcing the Contract, or for any breach thereof, including attorneys' fees in a reasonable amount. SECTION 74 -- LANGUAGE As used herein, words in the singular or plural and related verbs and pronouns shall include and signify both the plural and singular, and use of an shall include all genders, according to the context hereof, Y Sender SECTION 75 PURCHASE OF MATERIALS BY OWNER The Owner desires to purchase certain materials which will be utilized in the work. The Contractor agrees that the following conditions shall apply: a• The Owner and the Contractor shall mutually agree which materials the Owner will purchase. b• The cost of such materials, together with the amount the Contractor would have paid as sales tax, shall be deducted from the Contract sum as specified. REVISED: January 1, 1982 THE CHURCH OF JESUS CHRIST CF LATTER-DAY SAINTS CHURCH' EDUC4TIONAL SYSTEbf GENERAL CONDITIONS c. -M e. f. 9. er and the Contractor as to the Mallrnecessary upon agreement between the Own will furnish to the Own ro eces the Owner is to purchase, to enable the Owner top P information, including source of supply, p;lrchase such materials. failure of defect, � er harmless of and from any loss, claim, Contractor shall hold the Own purchased resulting �ralating to such material the suppliers of materials so P or any other problem discrepancy, delay in delivery caused by acts or omissions of the except such failure is directly except where anY owner. shall remain as called for in the Camount of coverage or any All bands and insurance, force. 'there shall be no reduandon deduction for premiums surance. in full iums for said bonds Materials ordered by hn e Cwer will not be paid for until written approval has been given by the ConuactOT- -ons do not abrogate the Contraacstrequired by helContract- ity to complyconditions fully in the execution of the SECTION 76 - _ gEyEgABILITY enforceable, the remaining PT° - an arts of the contract do� ents are fol;�nd to be void, the same In the event Y P reason to be with contrary to law, or for any of the offensive parts as are necessary the contract documents shall nevertheless be binding deleted, visions of ortion a had been de force and eeffect orbillegaough lity are treated as if they to V.0 a th REVISED-1 January, 1982 0 THE CMRCH OF JESUS CG-IRIST OF LATTER-DAY SAINTS CHURCH EDUCATIONAL SYSTF'v1 GLNERAL CONDITIONS GC/43 SUPPLEMENTAL GENERAL CONDITIONS SECTION 1 - - GENERAL Su elemental General_ Conditions are hereby made a ga'+ °- Thesee enificetions with the same force aria e=:ec: each Section embodiedpherein. as if wholly _77r'TION 2 - - EXTENT OF PROJECT lif-, Fro Wherever, in thesE The project as embraced by this Contract shall include the co.�,�� work. building addition and site work as materials, like item= S ecifications reference is nstellationto msitrefers tolabik Specifications ar or for one 1 in the sing project. required for the completion of the SECTION 3 - - ONE CONTRACT shall be performed under one cEneral Work under this Contract contract and not divided intoseparatecontracts covering general, mechanical and electrical SECTION 4 - - DRAWINGS The Drawings herein referred to, and accompanying these Specifications are titled' PLANT SCIENCE BUILDING, BASEMENT REMODEL - The Church of Jesus Christ of Latter-DaY Saints Ricks College Rexburg, Idaho Project No. 7142 31 0101 Job No. 8776 Idaho; L.H. Pocatello. systems As prepared by CSHQA ARCHITECTS/PLANNERS. Engineered Y- En ineers; g Associates, Structural g Ballif Mechanical Engineers, Nielson Engineering. Associates Incorporated, Electrical Engineers, all of Pocatello, Idaho. SECTION 5 - - SECTIONS AND DIVISIONS ation of these Spec if icst ions tendedl tos l ons establiand eshlimits of Separ only and is not ln for convenience work. SECTION 6 - - ACCEPTANCE and Contract will be deemed evidence that sit_ lar of the the Contractor is f am; Signing work will Documents have been examined andaconditions under which the with the existing building THE CHURCH OF JESUS CHRIST OF LATTER DAY SAINTS CHURCH EDUCATION SYSTEM SGC/1 be done. Beginning of work indicates acceptance of the existing conditions. Extra payments will not be authorized for work could have been will b ng conditions. y careful examination o f site t' �t ite and SECTION 7 - - PERMANENT UTILITIES The work included under the Base Bid shall include the installa"ion and hook-up for all permanent utilties to serve the addition. SECTION N^' 8 -- PERSONNEL At�D EQ,1 IFME Maintain a construction force mechanics, craftsmen, and laborers, sufficienttowork to completion date indicated in including supervlsc�rs, member of Contractor's Contract Documents. organization shall be on the job ob anysible that work is being performed jab any time ct o subcontractors throughout the duration of ° the dprGjectr any of the Maintain construction equipmentsufficient for efficient prosecut ionaof work, in good condition, SECTION 10 - - STANDARD SPECIFICATIONS Throughout these Specifications reference is made to various widely published, standard, commercial specifications. The Contractor and subcontractor shall become familiar with the contents pertinent portions of those specifications and standards that and cited and referred to in these Specifications and Drawings. of the citation of a are standard specification shall be construed torefer the latest published revision and apply directly to the of such portions of it that relate this material or installation called for on jab. In case of conflict between the referenced specification project specifications, the ,ion and the In case Project specifications shall gov standards, of theonf conflict among the reference a n" one having the more stringent requirementsnshall govern. 1 The Contractor, if required, shall furnish an affidavit for the manufacturer, certifying that the to the project meet the requirementsteSpecifiedProducts deiHot�:ever.ivsusuch chcertification shall not relieve the Contractor from responsibilit, of complying with any added requirements specified herein. 1 SECTION 11 - - TEMPORAFY LIGHTIfJG The Contractor shall furnish, install and four 500-wall flood lights (includingmaintain a minimur„ �,f necessary equipment) located about all wiring and o+,E_ Properly illuminate the project where require-3 t,_, the construction area. These lights are to be THE CHURCH OF JESUS CHRIST OF LATTER DAY SAINTS CHURCH EDUCATION SYSTEM SGC/2 mounted or, posts a minimum of 14 feet from the ground in locations approved by the Owner's Representative. Lights shall be o nerat_ec from one -hour after sundown to one -hour before sunrise. SECTION 12 - - PROTECTIVE FENTING Provide a woven wir_e..- fence as a protective enclosure following the project limit lines of the project as showy, in the Drawings. Fencs is to be continuous but with sufficient gates as noted herEaftsr, 6 foot height without top rail. Erect sufficiently taut to maintain a uniform top level to the fence. a. The fabric mesh is to be 2" x 4" diamond mesh, Style I, wit: horizontal wire of two twisted strands of No. 12 1/2 ca,.:ae and cross wires of No. 14 gauge; all of copper bearinc steel "flame sealed against rust." b. Line posts are to be Tee section, studded, 8 foot length. she posts are to be drive-in type with anchors to secure posts firmly into position. Terminal and corner posts are to be 8 foot length made of 2 1/2" x 2 1/2" x 1/4" angle of the same length as the post. Line posts are to be spaced nit greater than 12 feet o.c. The fence is to be installed true to line and plumb. c. Provide two gates approximately where shown. Gates are to be 24 feet wide, double swing type formed of 1 1/4" steel pipe with welded joints, fully braced, and covered with fabric mesh as specified for the fencing. Provide gate with hinges of type and size suitable to the weight of the gate and provide a means of positive locking. d. Upon completion of the project the Contractor shall remove the fence and patch repair where blacktop has been damaged. SECTION 13 - - SCAFFOLDING AND HOISTING Erect and maintain scaffolds, runways, ramps, and ladders, necessary for reaching all portions of work conveniently and safely. Provide hoist, lifts, cranes, and towers to expedite building operations and handling of materials. Install, maintain and operate equipment in a manner that will prevent injury or damage. SECTION 16 - - UTILITIES The contractor shall provide all temporary utilities for the work and addition at his expense. Arrangements, however, may be ma.e with the owner to meter his utility lines and make payment to him on a pre -arranged schedule. Utility payment shall be made to the owner on a monthly basis until the addition is turned over to the THE CHURCH OF JESUS CHRIST OF LATTER DAY SAINTS CHURCH EDUCATION SYSTEM SGC/3 owner for occupancy. This shall include electricity, water ar:5,':•r steam as may be required. SECTION 17 - - SCHEDULING UTILITY SHUT DOWN It shall be incumbent upon the contractor to notify the owner least 24 hours before any shut down of utilties will be allowed which would affect the Plant Science Bvilding. The Plant Science Building, durinq its normal use, has many experiments, exotic plants, plant cultures, etc. in process and if unauthorized sh-�t downs should occur the loss to the Plant Science Department would be sizeable. This includes any and/or all period of the 2y day - night and includes shut downs of electricity, water and/or steam. It is imperative that this coordination be discussed and scheaol-ed with the owners approval and prior knowledge. It is imperative that the fire protective sprinkling system in the existing Plant Science Building be operative at all times. If, for any reason, a shut down would affect the operation of this sprinkling system, the owner shall be notified, the shut down held to an absolute minimum and shall be coordinated with the owner. THE CHURCH OF JESUS CHRIST OF LATTER DAY SAINTS CHURCH EDUCATION SYSTEM SGC/4 PERFORMANCE BOND KNOW ALL MEN BY THESE PRESENTS: That of as Principal, hereinafter called Contractor, and , as Surety, hereinafter called Surety, are held and firmly bound unto ' as Obligee, hereinafter called Owner, in the amount of ($ ), for the payment whereof Contractor and Surety bind themselves, their heirs, executors, administrators, succ:e5sors and assigns, jointly acid severally, firmly by these presents. WHEREAS, Contractor has by written agreement dated entered into a contract with Owner for in accordance with drawings and specifications prepared by , Architect, which contract is by reference made a part hereof, and is hereinafter referred to as the Contract. NOW, THEREFORE, THE CONDITION OF THIS OBLIGATION IS -such that, if Contractor shall promptly and faithfully perform said contract, then this obligation shall be null and void; otherwise it shall remain in full force and effect. The Surety hereby waives notice of any alteration or extension of time made by the Owner. Whenever Contractor shall be, and declared by Owner to be in default under the Contract, the Owner having performed Owner's obligations thereunder, the Surety may promptly remedy the default, or shall promptly: 1. Complete the Contract in accordance with its terms and conditions, or 2. Obtain a bid or bids for submission to Owner for completing the Contract in accordance with its terms and conditions, and upon determination by Owner and Surety of the lowest responsible bidder, arrange for a contract between such bidder and Owner, and make available as work progresses (even though there should be a default or a succession of defaults under the contract or contracts of completion arranged under this paragraph) sufficient funds to pay the cost of completion less the balance of the contract price; but not exceeding, including other costs and damages for which the Surety may be liable hereunder, the amount set forth in the first paragraph hereof. The term"balance of the contract price," as used in this paragraph, shall mean the total amount payable by Owner to Contractor under the Contract and any amendments thereto, less the amount properly paid by Owner to Contractor. THE CHURCH OF JESUS CHRIST OF LATTER-CAY SAINTS CHURCH EDUCATIONAL SYSTEM PB/l Any suit under this bond must be instituted before the expiration of two (2) years from the date on which final payment under the contract falls due. No right of action shall accrue on this bond to or for the use of any person or corporation other than the Owner named herein or the heirs, executors, administrators or successors of Owner. Signed and sealed this day of IN THE PRESENCE OF: STATE OF ) SS COUNTY OF ) A.D., 197 . (Sea 1) Principal Title (Seal) Principal Title , being first duly sworn an oath, deposes and says, that he is the of said Surety Company, and that he is duly authorized to execute and deliver the foregoing obligation; that said Surety Company is authorized'to execute the same and has complied in all respects with the laws of in reference to becoming sole Surety upon bonds, undertakings and obligations. Subscribed and sworn to before me this day of 197 My Commission expires: Notary Public THE CHURCH OF JESUS CHRIST OF LATTER-DAY SAINTS CHURCH EDUCATIONAL SYSTEM PB/2 LABOR AND MATERIAL PAYMENT BOND KNOW ALL MEN BY THESE PRESENTS: That as , of principal, hereinafter called Principal, and - as Surety, hereinafter are held and firmly bound unto called Surety as Obligee, hereinafter called Owner, for the use and benefit of claimants as hereinbelow defined, in the amount of , for the Dollars ($ executors, al and Surety bind themselves, their heirs, payment whereof Princip jointly and severally, firmly by these admi�.istrators, successors and assigns, j y presents. AREAS, Principal has by written agreement dated ' entered into a contract with Owner for is accordance with drawings and specifica- tions prepared by art hereof, and is hereinafter referred to which contract is by reference made a p as the Contract. OW THEREFORE, THE CONDITION OF THIS OBLIGATION is such that if the for rinallalabor N ' payment to all claimants as hereinafter defined, shall promptly make P ym for use is the performance of the Contract, and material used or reasonably required then this obligation shall be void; otherwise it shall remain in full force an effect, subject, however, to the following conditions: 1. A claimant is defined as one having a direct contract with the Principal or with a subcontractor of the rinipal use for labin ors material, or both, used or reasonably requiredconstrued performance of the contract, labor and material being lightheat, oil, to include that part of water, gas, power, gasoline, telephone service or rental of equipment directly applicable to the Contract. THE CHURCH OF JESUS CHRIST OF LATTER-DAY SAINTS CHURCH EDUCATIONAL SYSTEM LMPB/1 2. The above named Principal and surety hereby jointly and severally agree with the Owner that every claimant as herein defined, who has not been paid in full before the expiration of a period of ninety (90) days after the date on which the last of such claimant's work or labor was done or performed, or materials were furnished by such claimant, prosecute the suit to final judgment for such sum or sums as may be justly due claimant and have execution thereon. The Owner shall not be liable for the payment of any costs or expenses of any such suit. 3. No suit or action shall be commenced hereunder by any claimant. a) Unless claimant, other than one having a direct contract with the Principal, shall have given written notice to any two of the following: The Principal, the Owner, or the Surety above named, within ninety (90) days after such claimant did or performed the last of the work or labor, or furnished the last of the materials for which said claim is made, stating with substantial accuracy the amount claimed and the name of the party to whom the materials were furnished, or for whom the work or labor was done or performed. Such notice shall be served by mailing the same by registered mail or certified mail, postage Dr -,)aid, in an envelope addressed to the Principal, Owner or Surety, at any place where an office is regularly maintained for the transaction of business, or served in any manner in which legal process may be served in the state in which the aforesaid project is located, save that such service need not be made by a public officer. b) After the expiration of one (1) year following the date -on which Principal ceased work on said contract, it being understood, how- ever, that if any limitation embodied in this bond is prohibited by any law controlling the construction hereof such limitation shall be deemed to be amended so as to be equal to the minimum period of limitation permitted by such law. c) Other than in a state court or competent jurisdiction in and for the county or other political subdivision of the state in which the project, or any part thereof, is situated or in the United States District Court for the district in which the project, or any part thereof, is situated, and not elsewhere. 4. The amount of this bond shall be reduced by and to the extent of any payment or payments made in good faith hereunder, inclusive of the pay- ment by Surety of mechanic's liens which may be filed of record against said improvement, whether or not claim for the amount of such lien be presented under and against this bond. THE CHURCH OF JESUS CHRIST OF LATTER-DAY SAINTS CHURCH EDUCATIONAL SYSTEM L' ?B/2 Signed and sealed this day of A.D., 197 IN THE PRESENCE OF: (Seal) Principal Title (Seal) Surety Title STATE OF ) SS COUNTY OF ) , being first duly sworn an oath, deposes and says, that he is the of said Surety Company, and that he is duly authorized to execute and deliver the fore- going obligation; that said Surety Company is authorized to execute the same and has complied in all respects with the laws of in refer- ence to becoming sole Surety upon bonds, undertakings and obligations. Subscribed and sworn to before me this day of 197 My Commission expires: Notary Public THE CHURCH OF JESUS CH RIST OF LATTER-DAY SAINTS CHURCA EDUCATIONAL SYSTMM LMPB/3 CONTRACT FOR CONSTRUCTION OF SLANT SCIENCE BUILDING BASEMENT REMODEL Project 7142 31 0101 Project No. AT RICKS COLLEGE THIS CONTRACT, made and executed in quadruplicate original as of the day of , 19 , by and between RICKS COLLEGE, a Utah corporation, having its principal office at Rexburg, Idaho (thereinafter referred to as "Owner") , and of "Contractor".) WITNESSETH: (hereinafter referred to as That for and in consideration of the payments hereinafter specified to be paid by the Owner to the Contractor and the covenants and agreements herein con- tained to be kept and performed by the parties hereto, the Contractor agrees to build and construct the proposed at Ricks College in Rexburg, Idaho, known as Project No. (hereinafter referred to as the "Project"), and to furnish all labor, supervision, equipment, transportation and power, to furnish and deliver all materials, and perform and supervise all work as required herein and by the contract documents hereinafter identified, all of which shall collectively constitute the contract, and shall hereinafter be referred to collectively as the "Contract" . THE CHURCH OF JESUS CHRIST OF LATTER-DAY SAINTS CHURCH EDUCATIONAL SYSTEM CONTRACT C/1 ARTICLE I. A. THE IDENTIFICATION OF CONTRACT DOCUMENTS. The "plans" for the Project consist of Drawings, prepared by , and approved , 19 0 which plans are identified as follows: B. The "specifications" for the Project as prepared by and approved 19 which specifications are identified as follows: C . Addendum No. issued 19 ARTICLE II. DATE OF COMPLETION. The Contractor agrees to complete the work required by the Contract on or before midnight, 19 Time is hereby expressly declared to be of the essence of the Contract. ACTICLE III. THE CONTRACT SUM. The Owner agrees to pay to the Contractor, in accordance with the terms hereof, a total of , which sum the Contractor agrees to accept as full compensation for performing his obligations under the Contract. ARTICLE IV. THE CONTRACTOR'S REPRESENTATIVE. The Contractor's Representative is ARTICLE V . THE OWNER'S REPRESENTATIVE. The Owner's Representative is IN WITNESS WHEREOF, the Owner has caused this instrument to be signed by its President, attested by its Secretary, and its corporate seal to be here- unto affixed, and the Contractor has hereunto affixed his signature as of the day and year first above written. -2- ATTEST: Secretary ACKNOWLEDGED: Support Services Vice President - Church Colleges and Schools Church Building Division Office, Commissioner of Education RICKS COLLEGE a Utah corporation By: President Doing business under the firm name of By: Contractor -3- m m c n LC 0 9 r-. z t 1 "V m G7 oa 3 d � o ° Z— o� �m n � n n� r n� cn Ln LA m d y C4 v _a Z n n R R r z a c c w it c M rD M ti A SECTION 02070 - SELECTIVE DEMOLITION Extent of building demolition work is shown on drawings- T es of Selective Demolition Work: Demolition requires the selective removal and subsequent offsite disposal of the followings Portions of building structure indicated on drawings and ew construction. required to accommodate n Interior partitions as indicated on drawings - Removal and protection of existing fixtures and equipment items indicated "salvage". Removal work specified elsewhere: work and patching is included within Remodeling construction °r new the respective sections of specifications, oecif ica io s,intinc remodel remodeling o materials for re -use and incorporated construct ion. conduits, ducts, other mechanical and Relocation of pipes, specified by respective trades. electrical work are sequence of Schedule: Submit schedule indicating proposed Representative emoli operations for selecommencementtofnwork. work to owner's coordination for prior to of utility services as for review p and continuation shut-off, capping, required, together with details for dust and noise contra l. emoval Provide detailed sequence °eowner'snon-site nd roperations. rk_to ensure uninterrupted progress of occupying areas of the of selective vdemolition. Occupancy: Owner will be continuously PY g building immediately adjacent o work asn mannerthatwillminimize Conduct selective demolitionProvide minimum need for disruption of Owner's normal operations. of 72 hours advance notice to owneroof demolition activities which will severely impact owner's norms ion o f Structures: Owner assumes hno ed, responsibility for Condit actual condition of structures to be demolished. e of commencement of contract will be Conditions existing at tim far as practicable. However, variations Owner insofar maintained by occur by Owner's removal and salvage within structure may operations prior to start of demolition work. ial Demolition and Removal: Items indicated to be removed but Part be removed from structure as value to Contractor may the are of salvable items from site as Y work progresses. Transport salvaged removed. permitted. Storage or sale of removed items on site will not be 02070 - 1 8776/SELECTIVE DEMOLITION RICKS COLLEGE/ PLANT SCIENCE REMODEL Protections: Provide ora protection as required toemprot y ct public from injury due to selective Provide protective measures safe passage of Owner's personnel occupied portions of building. barricades and other forms of Owner's personnel and general demolition work. as required to provide free and and general public to and from Erect temporary covered passageways as required by authorities having jurisdiction. Protect from damage existing finish work that is to Place and becomes exposed during demolition operations. remain in Provide floors with suitable coverings when necessary. Construct temporary insulated solid required to separate areas where noisdusy partitions where dust operations are performed. Y extensive dirt or doors and security locks if requiredlp partitions with dustproof Provide temporary weather protection during interval between demolition and removal surfaces, and installation of new g construction on exterior no water leakage construction to insure that areas of existing builor ddamage occurs to structure or interior ding. Remove protections at completion of work. Damages: Promptly repair damages caused to adjacent facilities b demolition work at no cost to Owner. Y Traffic: Conduct removal in a manner streets, walks, and selective demolition operations and to ensure minimum interference with roads, other adjacent occupied or used facilities. Utility Services: remain, Maintain demolition eoperations. vice, and existing utilities indicated to protect against damage during Do not interrupt existing facilities, utilities serving occupied or used faexcept when authorized having jurisdiction. in writing by authorities interruptions to existing utilities, asacceptabletogovernin rvide mporary services during _ authorities. a Environmental Controls: Use sure,, and other suitable methods atorlimtdust and dirt rising sprinkling,temporary enclo- sures, in air to lowest practical level, regulations pertaining to environmental Comply with governing regulations protection. Do not use water when it may create conditions such as ice, floodin hazardous or objectionable Inspection: inspect areas g, and pollution. Prior to commencement in which work will be 8776/SELECTIVE DEMOLITION RICKS COLLEGE/ PLANT SCIENCE REMnnFr. Of selective demolition work, performed. Photograph existing 02070 - 2 conditions to structure surfaces, equipment or to surrounding properties which could be misconstrued as damage resulting from selective demolition work; file with Owner's Representative prior to starting work. Preparation: Provide interior and exterior shoring, bracing, or support to prevent movement, settlement or collapse of structures to be demolished and adjacent facilities to remain. Cease operations and notify Owner's Representative immediately if safety of structure appears to be endangered. Take precau- tions to support structure until determination is made for continuing operations. Cover and protect furniture, equipment and fixtures to remain from soiling or damage when demolition work is performed in rooms',or areas from which such items have not been removed. Erect and maintain dust -proof partitions and closures as required to prevent spread of dust or fumes to occupied portions of the building. Where selective demolition occurs immediately adjacent to occupied portions of the building, construct dust -proof partitions of minimum 4" studs, 5/8" drywall (joints taped) on occupied side, 1/2" fire -retardant plywood on demolition side, and filled partition with sound -deadening insulation. Provide weatherproof closures for exterior openings resulting from demolition work. Locate, identify, stub off and disconnect utility services that are not indicated to remain. Provide by-pass connections as necessary to maintain continuity of service to occupied areas of building. Provide minimum of 72 hours advance notice to Owner if shut -down of service is necessary during change -over. Demolition: Perform selective demolition work in a systematic manner. Demolish concrete and masonry in small sections. Cut concrete and masonry at junctures with construction to remain using power -driven masonry saw or hand tools; do not use power -driven impact tools. Locate demolition equipment throughout structure and promptly remove debris to avoid imposing excessive loads on supporting walls, floors or framing. Provide services for effective air and water pollution controls as required by local authorities having jurisdiction. For interior slabs on grade, use removal methods that will not 8776/SELECTIVE DEMOLITION 02070 - 3 RICKS COLLEGE/ PLANT SCIENCE REMODEL crack or structurally disturb adjacent slabs or partitions. Use power saw where possible. Completely fill below -grade areas and voids resulting from demolition work. Provide fill consisting of approved earth, gravel or sand, free of trash and debris, stones over 6" diameter, roots or other organic matter. If unanticipated mechanical, electrical or structural elements which conflict with intended function or design are encountered, investigate and measure both nature and extent of conflict. Submit report to Owner's Representative in written, accurate detail. Fending receipt of directive from Owner's Representative rearrange selective demolition schedule as necessary to continue overall job progress without delay. Salvage Items: Where indicated on Drawings as "Salvage -Deliver to Owner", carefully remove indicated items, clean, store and turn over to Owne- and obtain receipt. Disposal of Demolished Materials: Remove debris, rubbish and other materials resulting from demolition operations from building site. Transport and legally dispose of materials off site. If hazardous materials are encountered during demolition operations, comply with applicable regulations, laws, and ordinances concerning removal, handling and protection against exposure or environmental pollution. Burning of removed materials is not permitted on project site. Clean -Up and Repair: Upon completion of demolition work, remove tools, equipment and demolished materials from site. Remove protections and leave interior areas broom clean. Repair demolition performed in excess of that required. Return structures and surfaces to remain to condition existing prior to commencement of selective demolition work. Repair adjacent construction or surfaces soiled or damaged by selective demolition work. END OF SLV SECTION 02070 8776/SELECTIVE DEMOLITION 02070 - 4 SECTION 03310 - CONCRETE Codes and Standards:ACI 301 "Specifications for Structural ACAC 318, "Building Code Requirements for Concrete for Buildings��, with applicable provisions except as Reinforced Concrete."; comply otherwise indicated. ory to Concrete Testing Service: Employ testingCacceptable designtesting concretetmixes. tn perform material evaluaio, arate testing laboratory to evaluate concrete Owner will employ se p delivered to and placed at site. Certificates, signed by concrete producer and Contractor, may be submitted in lieu of material testing reports when acceptable to Architect. r ling and testing during concrete Quality Control: Perform samp placement, as follows: laboratory will perform sampling Quality Control: Owner's testingwhich may include the and testing during concrete placement, following, as directed by Architect. This testineteoesnnot re ieve Contractor of responsibility of providing tContractor may perform additional testing as with specifications. Owner, to ensure quality of concrete. necessary, at expense to Samples:: ASTM C 172. Slum , ASTM C 143, one test for charge. Air Content: ASTM C 1730, one strength specimens. each load at point of dis- for each set of compressive Compressive Strength: ASTM C 39, one set or fraction thereof of each class of tested at 7 days, one specimen tested retained for later testing, if required. of a given class of concrete is less tests may be waived by Architect if evidence of satisfactory strength. When the total quantity than 50 cu. yds., strength field experience indicates Test results will be reported in writing and concrete producer within 24 hours after for each 50 cu. yds. concrete; one specimen at 28 days, and one to Architect, Contractor tests are made. product Manufacturer's Data: Submit maproprietarys materials installation instructionsacce6sorPesP admixtures, joint reinforcement and forming h deners, curing materials, and others as requested by data with including materials, Architect. ar Laboratory Reports: Submit copies andfmixlaboratory designs,test or evalua- tion reports for concrete materials 033 10 - 1 8776/CONCRETE RICKS COLLEGE/ PLANT SCIENCE REMODEL Mix Proportions and Design: Proportion mixes complying with mix design procedures specified in ACI 301. Submit written reports to Architect for each proposed concrete mix at least 15 days prior to start of work. Do not begin concrete production until mixes have been reviewed and are acceptable to Architect. Mix designs may be adjusted when material characteristics, conditions, weather, job test results or other circumstances warrant. Do not use revised concrete mixes until submitted to and acceptable by Architect. Use air-entrainina admixtures in all concrete, providing not less than 4 percent nor more than 6 percent entrained air for concrete exposed to freezing and thawing, and from 2 percent to 4 percent for other concrete. Concrete Materials: Portland Cement: ASTM C 150, Type as required. Flv-Ash: ASTM C 618, Type C or Type F. Limit use of fly ash in concrete mix design to not exceed 25 percent of cement content by weight. Aggregates: ASTM C 33, except local aggregates of proven durabil- ity may be used when acceptable to Architect. Water: Drinkable. Air -Entraining Admixture: ASTM C 260. Water -Reducing Admixture: ASTM C 494; type as required to suit project conditions. Only use admixtures which have been tested and accepted in mix designs, unless otherwise acceptable. Related Materials: Moisture Barrier: Clear 8-mils thick polyethylene; polyethylene - coated barrier paper; 1/8" thick asphalt core membrane sheet. Membrane -Forming Curing Compound: ASTM C 309, Type I. Joint Fillers: See Division-7. Form Materials: ------------- Provide form materials with sufficient stability to withstand pressure of placed concrete without bow or deflection. Exposed Concrete Surfaces: Suitable material to suit project conditions. Reinforcing Materials: 8776/CONCRETE RICKS COLLEGE/ PLANT SCIENCE RFMnnVT. 03310 - 2 Deformed Reinforcing Bars ASTM A 615, Grade 60, unless otherwise indicated. Welded Wire Fabric: ASTM A 185. Forming and Placing Concrete: Job -Site Mixing: _Use drum type batch machine mixer, mixing not less than 1-1/2 minutes for one cu. yd. or smaller capacity. Increase mixing time at least 15 seconds for each additional cu. yd. or fraction thereof. Ready -Mix Concrete: ASTM C 94. Formwork: Construct so that concrete members and structures are of correct size, shape, alignment, elevation and position. Provide openings in formwork to accommodate work of other trades. Accurately place and securely support items built into forms. Clean and adjust forms prior to concrete placement. Apply form release agents or wet forms, as required. Retighten forms during concrete placement if required to eliminate mortar leaks. Reinforcement: Position, support and secure reinforcement against displacement. Locate and support with metal chairs, runners, bolsters, spacers and hangers, as required. Set wire ties so ends are directed into concrete, not toward exposed concrete surfaces. Install welded wire fabric in as long lengths as practicable, lapping at least one full mesh. Joints: Provide construction, isolation, and control joints'as indicated or required. Locate construction joints so as to not impair strength and appearance of structure. Place isolation and control joints in slabs -on -ground to stabilize differential settlement and random cracking. Installation of Embedded Items: Set and build into work anchorage devices and other embedded items required for other work that is attached to, or supported by, cast -in -place concrete. Use setting drawings, diagrams, templates, and instructions provided by others for locating and setting. Concrete Placement: Comply with ACI, placing concrete in a continuous operation within planned joints or sections. Do not begin placement until work of other trades affecting concrete is completed. Consolidate placed concrete by mechanical vibrating equipment with hand rodding and tamping so that concrete is worked around reinfor- cement and other embedded items and into forms. Protect concrete from physical damage or reduced strength due to weather extremes during mixing, placement and curing. 8776/CONCRETE 03310 - 3 RICKS COLLEGE/ PLANT SCIENCE REMODEL In cold weather comply with ACI 306. In hot weather comply with ACI 305. Concrete Finishes: Exposed -to -View Surfaces: Provide a smooth finish for exposed concrete surfaces and surfaces that are to be covered with a coating or covering material applied directly to concrete. Remove fins and projections, patch defective areas with cement grout, and rub smooth. Slab Trowel Finish: Apply trowel finish to monolithic slab surfaces that are exposed -to -view or are to be covered with resilient flooring, paint or other thin film coating. Consolidate concrete surfaces by finish troweling, free of trowel marks, uniform in texture and appearance. Curing: Begin initial curing as soon as free water has disap- peared from exposed surfaces. Where possible. keep continuously moist for not less than 72 hours. Continue curing by use of moisture -retaining cover or membrane -forming curing compound. Cure formed surfaces by moist curing until forms are removed. Provide protections as required to prevent damage to exposed concrete surfaces. END OF SECTION 03310 8776/CONCRETE 03310 - 4 RICKS COLLEGE/ PLANT SCIENCE REMODEL SECTION 05120 — STRUCTURAL STEEL Standards: AISC Steel "Code of Standard Practithef °Design, es and p,ISC 'Spec if icat ions for Buildings and Bridges"; of Structural Steel for Buildings",eel"; and Erection Of Code Fabrication' "Structural Welding including pro visions, " t except as otherwise indicated. comply with applicable p Steel Plates, Shapes, Bars: ASTM A 36. ed Steel Tubing. ASTM A 500, Cold FormGrade B. Steel Pipe ASTM A 53, Type E or S, Grade B. Fasteners: High —strength bolts and nuts, ASTM A 315 or A 490, unfinished bolts and nuts, ASTM A 307, Grade A. Shop P FS TT—P, Type II; or, SSPC—Paint 2. Fabrication: Comply with AISC "Specifications" and final shop drawings. Mark and match —mark units for field assemb high —strength Connections: As shown on final shop drawings. Use 9 bolts for field connections, except as otherwise indicated.quality of C�mnly with AWS Code for procedures, appearance, and welds. el members to Other Work: Fabricate structuassage ral eof other work Provisions for other work and for p provide holes for securing ndicated. through steel framing as iPaintin ers or Paint structural steel work, rtar, and mcontact Shop Q bolted. Clean steel free of lOrovidemill a portions of beemweldedmbodded in concrete o paint to p areas to Apply prime scale, rust, oil and grease. PP Y minimum dry film thickness of 2.0 mils. with AISC Code and Specifications, and maintain Comply erection. Provide Ere--n� P y remove when final work in safe and stable condition asonLequired; temporary bracing and shoring connections are in place. wedges or surfaces, using aces with Set base plates on cleaned lre a in�Olidly pack open sp as req ng of 1 part Portland cement to 3 parts other adjustments hydration, or use bedding mortar, conssti r for packing and by sand and only enough commercial non —shrink grout material at Erector's option. S lice members final shop drawings - only where shown on 05120 — 1 8776/STRUCTURAL STEEL RICKS COLLEGE/ PLANT SCIENCE REMODEL Touch-up primp paint after erection. connections and abraded areas, a Clean field welds, and bolted in shop. pply same type paint as used END OF SECTION 05120 8776/STRUCTURAL STEEL RICKS COLLEGE/ PLANT SCIENCE REMODEL 05120 - 2 SECTION 05400 - COLD -FORMED METAL FRAMING Types of cold -formed metal framing units for project include the following: Load -bearing punched channel studs. "C"-shaped load -bearing steel studs. "C" shaped steel joists. Shop Drawings and Data: Submit shop drawings for special com- ponents and installations not fully dimensioned or detailed in manufacturer's product data. Include placing drawings for framing members showing size and gage designations, number, type, location and spacing. Indicate supplemental bracing, splices, accessories, and details as required for prover installation. Component Design: Calculate structural properties of studs and joists in accordance with AISI "Specification for Design of Cold - Formed Steel Structural Members". Fire -Rated Assemblies: Where framing units are components of assemblies indicated for a fire -resistance rating, including those required for compliance with governing regulations, provide units which have been approved by governing authorities having jurisdiction. Manufacturers; one of the following: Alabama Metal Industries Corp. Bostwick Steel Framing Co. Dale Industries„ Inc. Milcor Division, Inryco Inc. Marino Industries Corp. U.S. Gypsum Co. System Components: With each provide manufacturer's standard lintels, clip angles, shoes, accessories as recommended by indicated, as needed to provide a Materials and Finishes: type of metal framing required, steel runners (tracks), blocking, reinforcements, fasteners, and manufacturer for applications complete metal framing system. For 16-gage and heavier units, fabricate metal framing components of structural quality steel sheet with a minimum yield point of 40,000 psi; ASTM A 446, A 570, or A 611. For 18 gage and lighter units, fabricate metal framing components of commercial quality steel sheet with a minimum yield point of 33,000 psi; ASTM A 446, A 570, or A 611. 8776/COLD-FORMED METAL FRAMING 05400 - 1 RICKS COLLEGE/ PLANT SCIENCE REMODEL Provide galvanized finish to metal framing components complying with ASTM A 525 for minimum G 60 coating. Provide prime coated finish with one coat of shop -applied red - oxide, zinc -chromate, or other similar rust -inhibitive primer. "C"-Shape Studs: Manufacturer's standard load -bearing steel studs of size, shape, and gage indicated, with 1.625" flange and flange return lip. Punched Channel Studs: Manufacturer's standard, factory punched, load -bearing steel studs of size, shape, and gage indicated, with 1. 375" flange. Joists: Manufacturer's standard C-shape sections of size shape, and gage indicated. Electrodes for Welding: Comply with AWS Code. Galvanizing Repair Paint: High zinc dust content paint for repair of galvanized surfaces damaged by welding, complying with M. I. Spec. MIL-P-21035. Prefabrication: Structural framing components may be prefabricated. into panels prior to erection. Fabricate panels plumb, square, true to line and braced against racking with joints welded. Perform lifting of prefabricated panels to prevent damage or distortion. Fabricate panels in jig templates to hold members in proper alignment and position and to assure consistent component place- ment. Fastenings: Attach similar components by welding. Attach dissimilar components by welding, bolting, or screw fasteners, as standard with manufacturer. Wire tying of framing components is not permitted. Fabrication Tolerances: Fabricate panels to maximum allowable tolerance variation from plumb, level, and true to line of 1/8" in 10' -Off. Install metal framing systems in accordance with manufacturer's printed or written instructions and recommendations, unless otherwise indicated. Install continuous tracks sized to match studs. Secure tracks as recommended by stud manufacturer for type of construction involved. Set studs plumb, except as needed for diagonal bracing or required for non -plumb wails or warped surfaces and similar requirements. Install supplementary framing, blocking and bracing in metal framing system wherever walls or partitions are indicated to 8776/COLD-FORMED METAL FRAMING 05400 - 2 D T f-TrO f"P1T T lve"_=I MT R&IM (_"t^TLAW� L" DL'Mf)T-MTT support fixtures, equipment, services, casework, heavy trim and furnishings, and similar work. Secure studs to top and bottom runner tracks by either welding or screw fastening at both inside and outside flanges. Install horizontal stiffeners in stud system, spaced (vertical distance) at not more than V —6" o.c. Weld at each intersection. Installation of Joists: Install level and plumb, complete with bracing and reinforcing as indicated. Provide not less than 1-1/2" end bearing. Reinforce ends with end clips, steel hangers, steel angle clips, steel stud section, end grain wood block, or as otherwise recommended by joist manufacturer. END OF SECTION 05400 8776/COLD—FORMED METAL FRAMING 05400 — 3 RICKS COLLEGE/ PLANT SCIENCE REMODEL SECTION 05500 — METAL FABRICATIONS General: Structural Performance: Provide the following assemblies capable of withstanding loadings indicated: Treads and Plat.f_orms of Steel Stairs: Uniform load of 100 lbf per sq. ft. or a concentrated load of 300 lbf so located as to produce maximum stress conditions. Handrails and Toprails: Concentrated load of 200 lbf applied at any point in any direction and a uniform load of 50 lbf per lin. ft. applied simultaneously in both vertical and horizontal directions. Guards: Intermediate rails, balusters and panel fillers; uniform load of 25 lbf per sq. ft. of gross area of guard, including open areas. Submittals: In addition to product data, submit the following: Shop Drawings: Showing details and of fabrication, assembly, and installation including templates for anchor bolt placement. Samples of materials and finished products as may be requested by Architect. Materials/Fabrication: General: For work exposed to view use materials selected for their smoothness and freedom from surface blemishes. Steel Plates, Shapes, Bars: ASTM A 36. Steel Tubing: ASTM A 500 or ASTM A 501. Structural Steel Sheets: ASTM A 570 or ASTM A 611, Class 1; of grade required for design loading. Steel Pipe: ASTM A 53, type and grade as required for design loading (if applicable), black finish unless galvanizing indicated; standard weight (Schedule 40) unless otherwise indicated. Concrete Inserts: Threaded or wedge type; galvanized ferrous castings, either galvanized ferrous castings, malleable iron, cast steel; with steel bolts, washers and shims; hot dip galvanized. Non —Shrink Non —Metallic Grout: CE CRD—C621, non —staining, non— corrosive, non—gaseous; recommended by mfr. for types of applications indicated. Fasteners: Provide bolts, nuts, lag bolts, machine screws, wood screws, toggle bolts, masonry anchorage devices, lock washers as required for application indicated and complying with applicable 8776/METAL FABRICATION 05500 — 1 RICKS COLLEGE/ PLANT SCIENCE REMODEL Federal standards. Hot -dip galvanize fasteners for exterior applications to comply with ASTM A 153. Shop Painting: Apply shop primer to surface of metal fabrications except those embedded in ocncrete or galvanized; comply with SSPC- PA1 and requirements indicated below: Surface Preparation: Comply with SSPC-SP6 "Commercial Blast Cleaning" for exterior work, and with. SSPC-SP3 "Power Tool Cleaning" for interior work. Shop Primer: Fabricator's standard, fast -curing, lead-free, "universal" primer complying with performance requirements of FS TT-P-6 4 5 . Stripe paint edges, corners, crevices, blots, welds and sharp edges. Galvanizing: ASTM A 386 for assembled products; ASTM A 123 for rolled, pressed and forged steel shapes, plates, bars and strip 1/8" and thicker; galvanized repair paint: MIL-P-12035 or SSPC- Pa int-20. Fabrication, General: Use materials of size and thickness shown or, if not shown, of required size, grade and thickness to produce strength and durability in finished product. Shop -paint all items not specified to be galvanized after fabrication. Weld corners and seams continuously, grind exposed welds smooth and flush. Form exposed connections with hairline, flush joints; use concealed fasteners where possible. Rough Hardware: Furnish custom fabricated bolts, plates, anchors, hangers, dowels, and other miscellaneous steel and iron shapes for framing and supporting and anchoring woodwork. Galvanize, unless otherwise indicated. Ladders: Fabricate ladders for locations shown, with dimensions, spacings, and anchorages as indicated. Comply with the requirements of ANSI A14.3, unless otherwise indicated. Provide sloping ladders (ship's ladders) where indicated. Fabricate of open type construction with structural steel channel or plate stringers, pipe handrails, and open steel grating treads, unless otherwise indicated. Provide all necessary brackets, fittings, and anchorages for installation. Loose Bearing Plates: Provide for steel items bearing on masonry or concrete, as shown. Drill plates to receive anchor bolts. Galvanize after fabrication. Loose Steel Lintels: Fabricate to sizes indicated. 8776/METAL FABRICATION 05500 - 2 RICKS COLLEGE/ PLANT SCIENCE REMODEL Galvanize after fabrication. Miscellaneous Framing and Supports: Provide as required to complete work and not included with structural steel framework. Fabricate of welded construction in as large units as possible; drill and tap as required to receive hardware and similar items. Include required anchors for building into other work; spaced not more than 24" o. c. Miscellaneous Steel Trim: Fabricate to shapes and sizes as required for profiles shown; continuous welded joints and smooth exposed edges. Use concealed field splices wherever possible. Provide cutouts, fittings, and anchorages; coordinate assembly and installation with other work. Shelf Angles: Fabricate to sizes indicated for attachment to support framing. Provide slotted holes to receive anchor bolts, spaced not more than 6" from ends and 24" o.c. Furnish wedge -type concrete inserts (WCI) complete with fasteners for securing shelf angles to cast -in -place concrete. Galvanize shelf angles to be installed on exterior concrete. Abrasive Surface Floor Plate: ASTM A 283, Grade A, with mfr's. standard abrasive granules rolled into surface. Steel Pipe Railings: Fabricate to dimensions shown, with smooth bends and welded joints using 1-1/2 steel pipe, unless otherwise indicated. Secure posts and rail ends to building construction as indicated. Provide black steel pipe for interior railings, primed after fabrication. Cast Treads and Thresholds: Cast-iron units with integral abrasive finish, of size and configuration indicated; with mfr' s. standard anchors for type of application indicated. Manufacturers: Subject to compliance with requirements, provide products by one of the following: American Abrasive Metals Co. American Safety Tread Co. Barry Pattern and Foundry Co., Inc. Safe-T-Metal Co., Inc. Stubbs Foundry Co. Wooster Products Inc. Steel Framed Stairs: Complete stair assemblies of type indicated and including metal framing, hangers, columns, railings, newels, balusters, struts, clips, brackets, bearing plates and other components required for support of stairs and platforms. Stair Framing: Fabricate stringers of structural steel channels or plates or a combination thereof, and platforms of 8776/METAL FABRICATION 05500 - 3 RICKS COLLEGE/ PLANT SCIENCE REMODEL structural steel channel headers and miscellaneous framing members, of size indicated or required to support design loadings. Metal Pan Risers, Subtreads, and Subplatforms: Form metal pans to configuration indicated from hot -rolled or cold -rolled steel. Weld risers and subtreads to stringers, and subplatform to platform framing members. Steel Floor Plate Treads and Platforms: Fabricate treads and platforms from raised pattern steel floor plate complying with FS QQ-F-461, Class 1, of pattern indicated or selected from mfr's. standards. Form treads of 1/4" thick plate with integral nosing and back edge stiffener. Weld treads and platforms to support framing. Installation: Perform cutting, drilling and fitting required for installation; set work accurately in location, alignment and elevation, measured from established lines and levels. Provide anchorage devices and fasteners where necessary for installation to other work. Set loose items on cleaned bearing surfaces, using wedges or other adjustments as required. Solidly pack open spaces with bedding mortar, consisting of 1 part portland cement to 3-parts sand and only enough water for packing and hydration, or use commercial non -shrink grout material. Touch-up shop paint after installation. Clean field welds, bolted connections and abraded areas, and apply same type paint as used in shop. Use galvanizing repair paint on damaged galvanized surfaces. END OF SECTION 05500 8776/METAL FABRICATION 05500 - 4 RICKS COLLEGE/ PLANT SCIENCE REMODEL SECTION 05520 - HANDRAILS AND RAILINGS: General: Definitions: Definitions in ASTM E 985 for railing -related terms apply to this section. Structural Performance of Handrail and RAiling Systems: Comply with ASTM E 895 based on testing per ASTM 89 and E 935. Structural Performance of Handrail and Railing Systems: Provide handrails and railing systems capable of withstanding the following structural loads without exceeding the allowable design working stress of the materials involved: Top Rail Guardrail Systems: Concentrated load of 300 lbf applied at any point and a uniform load of 100 lbf per linear ft. with each load applied nonconcurrently with respect to direction and each other, vertically downward or horizontally. Handrails Not Serving as Top Rails: Concentrated load of 200 lbf applied at any point and a uniform load of 50 lbf per lin. ft. with each load applied nonconcurrently with respect to direction and each other, vertically downward or horizontally. Infill Area of Guardrail Systems: Horizontal concentrated load of 200 lbf applied to one sq. ft. at any point in the system including panels, intermediate rails, balusters, or other elements composing the infill area. Submittals: In addition to product data, submit the following: Shop drawings showing railing layout and details of components, with structural computations. Products: Subject to compliance with requirements, provide handrails and railing systems fabricated as indicated in drawings. Steel and Iron: Provide steel and iron in the form indicated complying with the following requirements: Tubing: Cold -formed, ASTM A 500; or hot -rolled, ASTM A 501. Steel Plates, Shapes and Bars: ASTM A 36. Gray Iron Castings: ASTM A 48, Class 30. Malleable Iron Castings: ASTM A 47, grade as recommended by fabricator for type of use indicated. Fasteners: Same material as fastened metal; concealed unless otherwise indicated or unavoidable and standard with systems indicated. 8776/HANDRAILS AND RAILINGS 05520 - 1 RICKS COLLEGE/ PLANT SCIENCE REMODEL Anchors and Inserts: As required for secure anchorage of handrails and railings to concrete, masonry, and other adjoining work; noncorrosive to materials joined. Fabrication, General: Fabricate handra i le and ra i 1 irtgp tp design, dimensions, and details shown and as required to support design loadings indicated. Nonwelded Connections: Interconnect railing and handrail members using manufacturer's standard concealed mechanical fasteners and fittings. Welded Connections: Interconnect steel tube and bar handrails and railing members by welding; finish welds smooth, flush, and blended to match adjoining surfaces. Form bends by bending members, insertion of prefabricated elbow fittings, radius bends, or by mitering. Form single and compound curves by bending in jigs. Provide toeboards, wall returns, closed ends, brackets, flanges, fittings, sleeves as required for type of installation indicated. Ferrous Metal Paint Finish: Shop -primed after cleaning and pretreatment. Installation: Set work accurately in location, alignment, and elevation, plumb and free from rack. Comply with manufacturer's recommendations for field connections of handrail and railing members. Comply with applicable ASW code where welding is required or indicated. Anchor posts to metal surfaces with fitting designed for this purpose. END OF SECTION 05520 8776/HANDRAILS AND RAILINGS 05520 - 2 RICKS COLLEGE/ PLANT SCIENCE REMODEL SECTION 06100 - ROUGH CARPENTRY Products: Lumber, General: Manufacture lumber, 94S and gradestamped, to comply with PS 20 and applicable grading rules of inspection agencies certified by ALSC's Board of Review. Provide seasoned lumber with 19 percent moisture content at time of dressing shipment, for sizes 2" or less in thickness. Dimension Lumber: Provide lumber of the following product classification in grade and species indicated: Light -Framing: (2"-4" thick, 2"-4" wide). Construction grade. Structural Light Framing (2"-4" thick, 2"-4" wide): Grade and species indicated: No. 2 grade, Douglas Fir Structural Joists and Planks (2"- 4" thick, 5" and wider): Provide the following: No. 2 grade, Douglas Fir graded under WCLIB or WWPA rules: Fb (minimum extreme fiber stress in bending); 1500 psi. E ( minimum modulus of elasticity) ; 1, 500, 000 psi. Exposed Framing Lumber: Hand select material at factory from lumber of species and grade indicated below for compliance with "Appearance" grade requirements of ALSC National Grading Rule; Hem -Fir, Select Structural Grade per WWPA rules. Redwood, Clear -All Heart Grade per RIS rules. Concealed Boards: Standard grade, any species graded under WWPA rules or No. 3 grade Southern Pine graded under SPIB rules. Lumber for Miscellaneous Uses: Unless otherwise indicated, provide Standard grade lumber for support of other work, including rooftop equipment and support bases, cant strips, bucks, nailers, blocking, furring, grounds, stripping and similar members. Construction Panels: For types of concealed applications indicated below, provide wood panel products complying with PS 1 where applicable, and with "APA Performance Standard and Policies for Structural Use Panels" (Form E445) for requirements indicated. For following types of applications where exposure durability classification or span rating is not give, provide EXPOSURE 1 and rating required to suit support spacing indicated. 8776/ROUGH CARPENTRY 06100 - 1 RICKS COLLEGE/ PLANT SCIENCE REMODEL Combination Subfloor-Underlayment: APA RATED STURD-I-FLOOR, square -edged if not otherwise indicated. Subflooring: APA RATED SHEATHING. Wall Sheathing: APA RATED SHEATHING. Roof Sheathing: APA RATED SHEATHING. Plywood Backing for Electrical and Telephone Equipment: APA C-D PLUGGED INT with exterior glue, in thickness indicated, or, if not otherwise indicated, not less than 15/32". Hardboard Underlayment: 4' x 4' panels complying with ANSI A135.4, Class 4 (service), surface S1S; sanded on back side to uniform thickness of 0.215" or 0.200", as standard with manufacturer, plus or minus 0.005". Particleboard Underlayment: ANSI A 208.1, graded 1-M-1 in thickness indicated. Gypsum Sheathing: ASTM C 79, FS SS-L-30, Type II, Class 2, Form A and complying with the following requirements: Grade X: Fire-resistant treated core, 5/8" thick. Size and Edges: 4' x 8', square edges. Fasteners and Anchorages: Of size, type, material and finish suited to applicable shown. Provide metal hangers and framing anchors of the size and type recommended for intended use by manufacturer. Hot -dip galvanize fasteners and anchorages for work exposed to weather, in ground contact and high relative humidity to comply with ASTM A 153. Building Paper: Asphalt saturated felt, non -perforated ASTM D 226. Air Infiltration Barrier: Vapor permeable, water-resistant fabric composed of polyethylene fibers 6.1 mils thick. Preservative pressure treat lumber and plywood with water -borne preservatives to comply with AWPA C2 and C9, respectively, and with requirements indicated below: Wood for Ground Contact Use: AWPB LP-22. Wood for Above -Ground Use: AWPB LP-2. Treat cants, nailers, blocking, stripping, and similar in connection with roofing, flashing, vapor barriers and water- proofing. Treat sills, sleepers, blocking, furring, stripping and similar items in direct contact with masonry or concrete. Fire -Retardant Treated Wood: Where wood is indicated for fire - retardant treatment comply with AWPA C20 (lumber) and C27 (plywood) 8776/ROUGH CARPENTRY 06100 - 2 RICKS COLLEGE/ PLANT SCIENCE REMODEL for treatment type indicated below. Provide label of UL or other testing and inspecting agency acceptable to authorities having jurisdiction on each piece treated. Redry treated lumber. Interior Type A: Use where "FRTW" wood is indicated on interior. Exterior Type: Use where "FRTW" wood is indicated for exterior, exposed applications. Installation: Install rough carpentry work to comply with "Manual of House Framing" by National Forest Products Assoc. ( N. F. P. A. ) and with recommendations of the American Plywood Assoc. (APA), unless otherwise indicated. For sheathing, underlayment and other products not covered in above standards, comply with recommenda- tions of manufacturer of product involved for use intended. Set carpentry work to required levels and lines, with members plumb and true and cut to fit. Securely attach carpentry work to substrates and supporting members using fasteners of size that will not penetrate members where opposite side will be exposed to view or receive finish materials. Install fasteners without splitting wood; fasten panel products to allow for expansion at joints unless otherwise indicated. Provide wood framing members of size and spacing indicated; do not splice structural members between supports. Firestop concealed spaces with wood blocking not less than 2" thick, if not blocked by other framing members. Fasten structural wood panel products as follows: Sheathing: Nail to framing. Staple or nail to framing. Air Infiltration Barrier: Cover wall sheathing with air infiltra- tion barrier in compliance with manufacturer's printed directions. END OF SECTION 06100 06 100 - 3 8776/ROUGH CARPENTRY RICKS COLLEGE/ PLANT SCIENCE REMODEL i ►� L _ :� ' I _ J . _J_74�X4 �=J., � fro'-� �� � - >•_ - :'$ � _� �.�...� .r .lt, ,�• - 3� ter- ��-,i�'i'T F.Imo- - c ir• J� - - +w ti i Ji 'F - r L DID SJ: .7C c •� r •_ 'r1-.. '- -'- mp r yam.a- 1 r SECTION 06200 - FINISH CARPENTRY Product Data: Submit for factory -fabricated paneling. Samples: Submit samples of the following items: Lumber machined to stock and custom patterns, 2'-0" long x pattern width and thickness, for each configuration, species and grade indicated. Finish one side and one edge of samples for transparent f inished items. P_lVwood for transparent finish, 2' -0" panel width, finish applied to upper half of each piece. Softwood Lumber: Comply with PS 20 and applicable grading rules of d inspecting agency atternseCies usingnd product respective grading anseasoned indicated. Manufacture to sizes and p lumber. Use pieces made from solid lumber for transparent finished work, and glued -up or solid, at contractor's option for painted work. Furnish surfaced lumber for painted trim. Interior Standing and Running Trim for Trans arent or Painted Finish: Any Western Pine, Douglas Fir or White Fir species graded under WWPA rules as C Select or, for Idaho White Pine, as choice. Softwood Plywood: Provide APA graded panels as indicated complying with PS 1/ANSI A199. 1. P1 wood for Painted Finish: APA MDO EXT, panel dimensions as indicated. Hardwood Plywood: Stock panels of thickness and size indicated, complying with PS 51 for qualities indicated below: Face Veneer Species: Plain sliced Red Oak. Grade: Premium. Backing Veneer Species: Any hardwood veneer compatible with face veneer. Grade: Same as face grade. Construction: Lumber core. Plywood type: Type II (Interior). Face Pattern: Plain. Face Veneer Matchin (Panel -to -Panel): No match. Finish: Polish sanded. 06200 - 1 8776/FINISH CARPENTRY RICKS COLLEGE/ PLANT SCIENCE REMODEL Hardwood Lumber: Comply with referenced woodworking standard for quality of materials and fabrication and with requirements indicated. Woodworking Standard: AWI "Quality Standard. Standing and Running Trim for Transparent Finish: Plain sawn Red Oak fabricated to pattern and sizes indicated in the following grade: Premium. Fasteners and Anchorages: Provide nails, screws and other anchoring devices of type, size, material and finish suitable for intended use and required to provide secure attachment, concealed where possible. Fire -Retardant Treated Wood (FRTW): Where wood is indicated for fire -retardant treatment comply with AWPA C 20 (lumber( and AWPA C 27 (plywood) using fire -retardant which will not bleed through or adversely affect type of finish indicated and which does not require brush treatment after field cutting. Provide UL label on concealed surface of each piece. Redry treated lumber. Inspect each piece of lumber and plywood after treatment and drying; discard twisted, warped, bowed or otherwise damaged or defective wood. For FRTW wood exposed to exterior, use exterior type of treatment which results in no increase in fire performance rating when tested in accordance with ASTM D 2898, Method A (standard rain test). For interior FRTW wood not exposed to relative humidities in excess of 92%, use treatment chemicals with reduced hygroscopicity which are non -corrosive to metal fasteners, are non -blocking and permit use of transparent oil -based finishes. Install finish carpentry work plumb, level, true and straight with no distortions. Shim as required using concealed shims. Scribe and cut finish carpentry items to fit adjoining work. Anchor finish carpentry work securely to supports and substrates using concealed fasteners and blind nailing where possible. Use fine finishing nails for exposed nailing except as indicated, countersunk and filled flush with finished surface. Standing and Running Trim: Install with minimum number of joints possible, using full-length pieces from maximum length of lumber available. Cope at returns, miter at corners to produce tight fitting joints. Use scarf joints for end -to -end joints. END OF SECTION 06200 8776/FINISH CARPENTRY 06200 - 2 RICKS COLLEGE/ PLANT SCIENCE REMODEL SECTION 06400 - ARCHITECTURAL WOODWORK Standards: Comply with applicable requirements of the following: "Architectural Woodwork Quality Standards" by AWI. "Manual of Millwork" by WIC. Shop Drawinqs: Submit shop drawings for each item of architectural woodwork. Samples: Submit finished samples of each wood species and cut indicated for transparent finish; of each material indicated for finish of plastic opaque finish; of each color, pattern and laminate; and of each type of cabinet hardware. interior Wood: Solid Wood for Transparent Finish: Rift -sawn Red Oak. Solid Wood for Opaque Finish: Any closed -grain hardwood listed in referenced woodworking standard. plywood for Transparent Finish: Rift -cut Red Oak. Plywood for Opaque Finish: Hardwood plywood, yellow birch. Plastic Laminate: High pressure decorative laminate complying with NEMA LD 3, in color, pattern and finish indicated, or, if not chitect from manufacturers' standard indicated, as selected by Ar products. Interior Standing and Runnina Trims for Transparent Finish: Grade: Premium. Interior Standing and Running Trim for 0 a ue Finish: Grade: Custom. Plastic Laminate Finished Cabinets: Grade: Premium. Construction: Reveal overlay. osed Surfaces: GP-50 for non-postformed Plastic Laminate for Ex horizontal surfaces, PF-42 for postformed surfaces, and the following grades for vertical surfaces. GP-50. Plastic Laminate Countertop: 06400 - 1 8776/ARCHITECTURAL WOODWORK RICKS COLLEGE/ PLANT SCIENCE REMODEL Grade: Premium. Wood Stora a Shel,-inq for 0 ague Finish: Gr=de_: Custom Shelving Material: hardwood edge bands on exposedoedge5Ywood with veneer core and Finishes for Architectural Woodwork: Finishing of architectural woodwork is work of architectural woodwork. Provide factor finish s stem of type indicated for the following types of architectural woodwork. Interior trim for transparent finish. Casework. Shop -apply prime/base architectural coat to the following types of ion-9ksection "PaintingCe with requirements indicated in Divisin Interior trim for opaque finish. Wood storage shelving. Transparent Finish for open Grain Woods: e the finish in compliance with AWI "Architect ural1dWoodworkollowing Standards", Section 1500. Quality AWI Finish S stem #4: Vinyl. Grade: Custom. Staining: None required. Effect: Simulated oil finish. Cabinet Hardware and Acce hardware and accessor ssor Materials: y materials to Provide cabinet Y wit indicated for design, material, finish, manufacturer, etcquirements Installation: Install architectural woodwork straight with no distortion. plumb, level and shims, Scribe and cut woodwork to Shim required using concealed woodwork to anchors or blocking or directly to substrates,Ausing concealed fasteners. Standing and Running Trim: Install with minimum number of possible using full-length feces joints available. p from maximum length of lumber Cope at returns, miter at corners. Casework: Install without distortion so that doors and drawers fit openings and are properly aligned. Countertops: Anchor securely to base units. 8776/ARCHITECTURAL WOODWORK RICKS COLLEGE/ PLANT SCIENCE REMODEL 06400 - Wood Storage Shelving: Complete assembly of units and install in areas indicated including hardware and accessories. END OF SECTION 06400 06400 - 3 8776/ARCHITECTURAL WOODWORK RICKS COLLEGE/ PLANT SCIENCE REMODEL SECTION 07200 - INSULATION General' r-value represents the rate of heat flow Thermal resistivity or through homogenous material exactly 1" thick and are expressed by the temperature difference in degrees F between the two exposed faces required to cause 1 BTU to flow through 1 sq. ft. per hr. at mean temperatures indicated. ion ire Fire Performance Character indicated peroASTM Evide n119atASTMwith tf E84and performance characteristics UL E 136, as applicable, and which correspond to products listed in "Fire Resistance Directory" or "Building Materials Director Maximum Allowable Asbestos Content: Less than 0.25% by weight of asbestos of any type or mixture of types occurring natueSY er impurities, as determined by polarized light microscopy P Appendix A of 40 CFR 763. Submittals: Submit product data for each form and type of insula- tion indicated. Products: units in to applications General: Provide preformed manufacturer widthst standardthicknesses, indicated# selected fromwidths and lengths. C 665 for Type Faced Mineral Fiber BetwB III, Class A (blankets tht reflective ,vapoTMetarder membrane facing with flame spread of 25 or less); foil -scrim -draft vapor - retarder membrane on one face, respectively; and as follows: Mineral Fiber Type: Fibers manufactured from glass. Combustion Characteristics: test. Unfaced materials passes ASTM E 136 Surface Burnin Characteristics: smoke developed values of 25 and 50, Maximum flame spread and respectively. Sound Attenuation Blankets: FS HH-I-521, mineral fiber blanket without membrane, thicknesses as indicated. Adhesive for Bondin Insulation: insulation manufacturer. Mechanical Anchors: Type and size manufacturer. Installation: Type I; semi -rigid Class 25 flame -spread, Type as recommended by recommended by insulation General: Comply with insulation manufacturer's installation of insulation. instructions for 07200 - 1 8776/INSULATION RICKS COLLEGE/ PLANT SCIENCE REMODEL S�_� insulation units by adhesive both as applicable to location and conditionseindicatldanchora ge or END OF SECTION 07200 8776/INSULATION RICKS COLLEGE/ PLANT SCIENCE REMODEL 07200 - 2 SECTION 07510 — BUILT—UP ASPHALT ROOFING SYSTEM Classification: UL Class A rating. Roofing Warranty: Provide "Roofing Contractor's" standard 2—year roofing guarantee; MRCA form 1970A, or equivalent form. Aggregate —Surfaced Asphalt Built —Up Roofing: Base —sheet ply (ASTM D 2626, Type I) nailed if possible, otherwise mopped down with 20 lbs. (+255%) of steep asphalt (ASTM D 312, Type III). Prime cementitious substrate before base —sheet application, with 1.0 gal. per square of asphalt cut —back primer (ASTM D 41) . 3 courses of ply sheets, each mopped down with 20 lbs. (+ 25%) of asphalt of type indirated. Ply Sheets: No. 15 asphalt —saturated organic felt, perforated (ASTM D 226, Type I). Slopes 1/4" to 1/2": Asphalt Type II (flat), ASTM D 312. Aggregate surfacing course of 60 lbs. (+2596) of asphalt (Type I, dead level), plus 500 lbs. of gravel or crushed stone or 400 lbs. of slag, cast in hot, fluid asphalt. Provide aggregate complying with ASTM D 1863, or if unavailable, provide aggregate complying with ASTM D 448 gradations 6, 7, or 67, with maximum 3% moisture content and complying with all other requirements of ASTM D 1863. Manufacturers: Provide aggregate —surfaced asphalt built—up roofing system of one of the following: Celotex Corporation. Certainteed. Genstar Roofing Products Co. GAF Corporation. Manville Building Materials Corporation. Owens—Corning Fiberglas Corp. Tamko Corporation. Composition Flashing and Stripping: Provide composition flashing and stripping at edges and interruptions of roofing as shown and including the following: Two plies of glass fiber fabric (ASTM D 1688) set in and coated over with heavy coating of roofing cement (ASTM D 2822). Apply at metal flanges set on roof membrane at penetrations; set langes in a bed of roofing cement. Installation: Wood Board/Timber Substrates: Cover with 5—lb. red rosin —sized paper before installing roofing. 8776/BUILT—UP ASPHALT ROOFING SYSTEMS 07510 — 1 RICKS COLLEGE/PLANT SCIENCE REMODEL Tape joints of substrate to prevent penetration by roofing materials. Shingle multiple plies of roofing, unless otherwise required by felt manufacturer's instructions. Nailing: Where nailing is indicated and on nailable substrates, comply with felt manufacturer's recommendations, and with FM and UL requirements, for nailing of roofing to substrates. Substrate Moisture: Do not install roofing on wet insulation or other moist substrates. Do not apply hot bitumen under a condition which would cause foaming (due to moisture). Cant Strips: Provide molded fiber cant strips where possible, where edges of roofing adjoin vertical surfaces, to raise edges of roof membrane above main roof surface. Tapered Edge Strips: Provide tapered edge strips where possible, where edges of roofing do not adjoin a vertical surface, to raise edges of roof membrane above main roof surface. Nail edges of roofing where possible (without causing leaks), and nail composition flashing to vertical surfaces at edges and penetrations of roofing. Seal edges of built-up roofing to prevent flow of bitumen into building and drains. Provide envelope of roofing felt or, where envelope is not possible, provide large beads of roofing cement. END OF SECTION 07510 8776/BUILT-UP ASPHALT ROOFING SYSTEMS 07510 - 2 DTf VCZ rnT_T.7r.Fi PT,ANT SCIENCE REMODEL SECTION 07600 — FLASHING AND SHEET METAL Fabricated Sheet Metal, General: Conform to profiles and sizes shown, and comply with "Architectural Sheet Metal Manual" by SMACNA, for each general category of work required. Metal flashing and counter flashing. Aluminum Sheet: ASTM B 209, alloy 3003—H14; 0.032" (20 gage); C22A41 clear anodized finish. Fabricate sheet metal with flat —lock seams; solder with type solder and flux recommended by manufacturer, except seal aluminum seams with epoxy metal seam cement and, where required for strength, rivet seams and joints. Coat back —side of fabricated sheet metal with 15—mil sulfur —free bituminous coating, FS TT—C-494, or SSPC—Paint 12, where required to separate metals from corrosive substrates including cementitious materials, wood or other absorbent materials; or provide other permanent separation. Provide for thermal expansion of running sheet metal work, by overlaps or expansion joints in fabricated work. Where required for water —tight construction, provide hooked flanges filled with polyisobutylene mastic for 1" embedment of flanges. Space joints at intervals of not more than 50' for steel, 24' for copper or stainless steel, or 30' for zinc alloy or aluminum. Conceal expansion provisions where possible. Extruded Aluminum Trim and Flashings: Provide standard products conforming to the profiles and sizes indicated, alloy 6063—T52, 0.08" minimum thickness; complete with welded corner units, flashings and accessories. Finish: AA C22A41 clear anodized. Separate aluminum from contact with cementitious and absorptive surfaces, and from dissimilar metals, by a 15—mil coating of bituminous mastic (FS TT—C-494) or other permanent separation. Bed base units in roofing cement, FS SS—C-153. Installation Requirements: Anchor work in place with noncorrosive fasteners, adhesives, setting compounds, tapes and other materials and devices as recommended by manufacturer of each material or system. Provide for thermal expansion and building movements. Comply with recommendations of "Architectural Sheet Metal Manual" by SMACNA. Seal mnvina joints in metal work with elastomeric sealants, complying with FS SS—T-00227,—00230, or—001543. 8776\FLASHING AND SHEET METAL 07600 — 1 RICKS COLLEGE/ PLANT SCIENCE REMODEL Clean metal surfaces of soldering flux and other substances which could cause corrosion. Nail flanges of expansion joint units to substrates at spacing of 6" o. c. Composition Strip -ping: Cover flanges (edges) of work set on bituminous substrate with 2 courses of glass fiber fabric (ASTM D 1668) set in and covered with roofing cement, FS SS—C-153. Performance: Water—tight/weatherproof performance of flashing and sheet metal work is required. END OF SECTION 07600 8776\FLASHING AND SHEET METAL 07600 — 2 RICKS COLLEGE/ PLANT SCIENCE REMODEL SECTION 07700 — ROOF SPECIALTIES AND ACCESSORIES Standards: Comply with SMACNA "Architectural Sheet Metal Manual" details for fabrication of units, including flanges and cap — flashing to coordinate with type of roofing indicated. Comply with "NRCA Roofing and Waterproofing Manual" details for installation of units. Roof Accessory Materials; Miscellaneous Units: Fasteners: Match metal and finish of metal work, or provide nonmagnetic stainless steel, unless another type fastener is recommended by manufacturer of accessory unit. Roofing Cement: FS SS—C-153, type which is compatible with roofing, and nominally free of sulfur. Bituminous Coating: 15 mil bituminous mastic coating, FS TT—C-494 or SSPC—Paint 12, nominally free of sulfur. Mastic Sealant: Polyisobutylene type. Prefabricated Skylight Units: General: Unit shall consist of 2 3/4" thick double faced grid structures factory sealed into a screw clamp extruded aluminum frame at perimeter. Unit shall be installed with a minimum pitch of 4" in 12". Materials: Faces shall be fiberglass reinforced, with the following minimum performance characteristics: Color stability such that the exterior face will not change more than 3.0 units (Delta E by ASTM D-2244) after 5 years outdoor weathering in Sough Florida at 7 degrees facing South. Impact resistance minimum 60 ft. lbs. smoke development maximum 350 by ASTM E-84. Grid core shall be 6063—T6 aluminum I—beam, 7/16" flange width, mechanically interlocked to insure even munitn/mullion intersection. Bond strength over time, and shall have an initial bond strength of at least 700 P.S. I. (ASTM C-297) with no decrease after aging (12 cycles of ASTM D-1037). Exterior face of panel shall have a special erosion during manufacture. The surfacing shall be fully field repairable and refinishable if required. Grid core shall be mechanically interlocked extruded aluminum I —Beams with a thickness tolerance. of +.00311. Fiberglass faces shall be permanently bonded to aluminum grid core under heat and pressure. Aluminum frame shall be 6064— T5 aluminum with mitred and heli—arc welded at corners. Percent of light transmission — 0.24 U factor. Facing Sheets:- Exterior — Crystal Interior — Mid —White 8776/ROOF SPECIALTIES AND ACCESSORIES 07700 — 1 RICKS COLLEGE/ PLANT SCIENCE REMODEL Manufacturer: Provide the follwing or equivalent. Kalwall Corp.; Kalwall Insulated Skylight Curb Construction: Provide self -flashing units with integral, self-supporting double wall aluminum curb enclosing minimum 1" glass fiber board (or equivalent) insulation and with minimum 3" roof flanges. Installation: Anchor units securely to supporting structure. Coordinate installation with deck construction, vapor retarder (if any), insulation, roofing and flashing work, to provide waterproof and weatherproof installations, in accordance with Construction Details of NRCA Roofing and Waterproofing Manual. Separate dissimilar metals by coating surfaces with bituminous coating or other permanent separation. END OF SECTION 07700 !r 8776/ROOF SPECIALTIES AND ACCESSORIES 07700 - 2 RTrxS COLLEGE/ PLANT SCIENCE REMODEL SECTION 07900 - JOINT SEALERS General: Preconstruction Field Tests: Prior to installation of joint sealers, field-test their adhesion to joint substrates per field adhesion test in AAMA Aluminum Curtain Wall Series No. 13. Submittals: In addition to product data submit the following: Samples of each type and color of joint sealer required. Products: Compatibility: Provide joint sealers, joint fillers and other related materials that are compatible with one another and with joint substrates under conditions of service and application, as demonstrated by testing and field experience. Colors: Provide color of exposed joint sealer indicated or, if not otherwise indicated, as selected by Architect from manufacturer's standard colors. Elastomeric Sealant Standard: Provide manufacturer's standard chemically curing, elastomeric sealant of base polymer indicated, complying with ASTM C 920 requirements. Two -Part Nonsag Polysulfide Sealant: Type M; Grade NS; Class 12-1/2; Uses NT, M, G, A, and 0. One -Part Nonacid -Curing Silicone Sealant: Type S; Grade NS; Class 25, and as follows: Uses T, G, and A. Acrylic -Emulsion Sealant: Manufacturer's standard, one part, nonsag, acrylic, mildew -resistant, paintable, acrylic -emulsion sealant complying with ASTM C 834. Acoustical Sealant for Concealed Joints: Manufacturer's standard, nondrying, nonhardening, nonskinning, nonstaining, gunnable, synthetic rubber sealant recommended for sealing interior concealed joints to reduce transmission of airborne sound. Foamed -In -Place Fire -Stopping Sealant: Two-part, foamed -in -place, silicone sealant formulated for use in a through -penetration fire -stop system for filling openings around cables, conduit, pipes and similar penetrations through walls and floors, with fire - resistance rating indicated, per ASTM E 814; listed by UL or other testing and inspecting agency acceptable to authorities having jurisdiction. Sealant Backings, General: Nonstaining; compatible with joint substrates, sealants, primers and other joint fillers; approved for applications indicated by sealant manufacturer based on fie'_d experience and laboratory testing. 8776/JOINT SEALERS 07900 - 1 RICKS COLLEGE/ PLANT SCIENCE REMOnEL Plastic Foam Joint -Fillers: Preformed, compressible, resilient, nonwaxing, nonextruding strips of plastic foam of material indicated below, and of size, shape and density to control sealant depth and otherwise contribute to producing optimum sealant performance. Either flexible, open -cell polyurethane foam or nongassing, closed -cell polyethylene foam, unless otherwise indicated, subject to approval of sealant manufacturer. Bond -Breaker Tape: Polyethylene tape or other plastic tape as recommended by sealant manufacturer for preventing bond between sealant and joint filler or other materials at back of joint. Primer: As recommended by joint sealer manufacturer where required for adhesion of sealant to joint substrates indicated. Accessory Materials for Fire -Stopping Sealants: Forming, joint - fillers, packing and other accessory materials as required for installation of fire -stopping sealants. Execution: General: Comply with joint sealer manufacturers' instructions applicable to products and applications indicated. Elastomeric Sealant Installation Standard: Comply with ASTM C 962. Solvent -Release -Curing Sealant Installation Standard: Comply with ASTM C 804. Latex Sealant Installation Standard: Comply with ASTM C 790. Acoustical Sealant Application Standard: Comply with ASTM C 919 for use of joint sealants in acoustical applications. Installation of Fire -Stopping Sealant: Install sealant, including forming, packing and other accessory materials to fill openings around mechanical and electrical services penetrating floors and walls to provide fire -stops with fire resistance ratings indicated. END OF SECTION 07900 8776/JOINT SEALERS 07900 - L RICKS COLLEGE/ PLANT SCIENCE REMODEL SECTION 08110 — STEEL DOORS AND FRAMES Standards: In addition to other specified requirements, comply with Steel Door Institute "Recommended Specification for Standard Steel Doors and Frames" (SDI-100), for the following classifications: Submittals: With manufacturer's standard details and specifications for steel doors and frames, submit shop drawings showing application to project, as required. For door and frame assemblies required to be fire —rated and exceeding sizes of tested assemblies, submit manufacturer's certification that each assembly has been constructed to conform to design, materials and construction equivalent to labeled construction requirements. Manufacturer: One of the following: Allied Steel F-oducts, Inc. Amweld Bldg, Products Div. Ceco Corp. Curries Mfg. Div. Dittco Prod. Div. Fenestra Corp. Mesker Industries, Inc. Pioneer Bldrs. Products Corp./Div. CORE Industries, Inc. Steelcraft Mfg. Co. Trussbilt, Inc. Republic Builders Products Corp./Subs. Republic Steel. Fire —Rated Assemblies: Provide units that display appropriate UL or FM labels for fire —rating indicated. Over —size units will be acceptable if certified by manufacturer that each assembly is constructed the same as labeled units. Materials: Steel doors and frames; hot —rolled, pickled and oiled per ASTM A 569 and A 568; cold —rolled per ASTM A 366 and A 568. Galvanized sheets, ASTM A 526 with ASTM A 525, G 60 zinc coating, mill phosphatized. Anchors and Accessories: Manufacturer's standard units. Use galvanized items for units built into exterior walls, complying with ASTM A 153. -.r,rit�,a�; rigid, neat in appearance, and free from defects, warp or buckle. Weld exposed joints continuously, grind, dress, and make smooth, flush and invisible.. Prepare steel doors and frames to receive mortised and concealed finish hardware, including cutouts, reinforcing, drilling and tapping, complying with ANSI A 115 "Specifications for Door and Frame Preparation for Hardware". 8776/STEEL DOORS AND FRAMES 08110 — 1 IDTrYC rnT T.rr.V/ nT.BMT grrTF.N(R Rr.mnT)FT, a...... --- Reinforce units to receive surface -applied finish hardware to be field applied. Locate finish hardware as indicated or, if not indicated, per DHI "Recommended Locations for Builder's Hardware". Shop paint exposed surfaces of doors and frame units, includinq galvanized surfaces, using manufacturer's standard baked -on rust - inhibitive primer. Doors: Comply with SDI-100, of the types and styles indicated, for materials quality, metal gages, and construction details. Provide sightproof louvers for interior doors where indicated, constructed of 24 ga. steel V-shaped or Y-shaped blades, set into 20-ga. steel frame. Frames: Comply with SDI-100, of the types and styles indicated, for materials quality, metal gages and construction details. Provide standard hollow metal frames for doors, transoms, sidelights, borrowed lights, and other openings as indicated. Prepare frames to receive 2 silencers on strike jambs of single -swing frames and on heads of double -swing frames. Provide 26 ga. steel plaster guards or mortar boxes, welded to frame, at back of hardware cutouts where installed in concrete, masonry or plaster openings. Protect inside faces of frames in plaster or masonry wall construction which are placed with anti -freeze additives, using high -build fibered asphalt emulsion coating. Installation: Install hollow -metal units in accordance with manufacturer's instructions and final shop drawings Cif any). Fit doors to frames and floors with clearances specified in SDI- 100. Install fire -rated units in accordance with NFPA Std. No. 80. Finish hardware is specified in another Division-8 section. END OF SECTION 08110 8776/STEEL DOORS AND FRAMES 08110 - 2 10 Tf`YC hnT T "rNnj MT MOM 7'11•11^TTCMT SECTION 08210 — WOOD DOORS Standards: Comply with requirements of ANSI/NWMA I.S. 1 and Sect iur1 13riCi of AWI "Architectural Woodwork Quality Standards" except as otherwise indicated. �+:i-l+h1++ i g; In addition to prN►�u� � �s l� + 'r Samples for each type of door construction, face material and f inish required. Product warranty on door manufacturer's standard form, signed by Manufacturer, Installer and Contractor, agreeing to repair or replace defective doors as defined by referenced standards. Warranty shall be in effect during following periods of time after date of substantial completion. Solid Core Flush Interior Doors: Life of installation. Manufacturers: Subject to compliance with requirements, provide wood doors by one of the following: Algoma Hardwoods Inc. Cal —Wood Door Div.; Timberland Ind., Inc. Eggers Industries, Architectural Door Div. Glen —Mar Door Mfg. Co. Weyerhauser Company. General Wood Door Requirements: Exposed Surfaces: Same exposed surface material on both faces of each door, except as otherwise indicated. Louvers: Manufacturer's standard louvers of type, material and size indicated. Material: Color anodized aluminum, color to match Architect's sample. Fire —Rated Doors: Labeled and listed with rating required by a testing and inspection agency acceptable to authority having jurisdiction. Interior Solid Core Flush Doors for Transparent Finish: Faces: Red Oak, plain sliced. Grade: Premium. Construction: PC-5 or PC-7 (Particleboard core, 5— or 7—ply). Fire —Rated Solid -Core Doors: 08210 — 1 8776\WOOD DOORS RICKS COLLEGE/ PLANT SCIENCE REMODEL Faces and AWI Grade: Match faces and grade of non -rated doors in same area of building. Core Construction: Manufacturer's standard core construction required to provide fire —resistance rating indicated. X Edge Construction: Manufacturer's standard laminated edq_e construction for improved screw —holding ability. Prefinish wood doors for transparent finish with manufacturer's standard finishing system as selected by Architect from manufacturer's standards for stain color (if any) and gloss. Prefitting and Preparation for Hardware: Prefit and premachine wood doors at factory. Coordinate with finish hardware and door frame requirements. Installation: Install doors to comply with manufacturer's instructions. END OF SLV SECTION 08210 8776\WOOD DOORS 08210 — 2 RICKS COLLEGE/ PLANT SCIENCE REMODEL SECTION 08410 — ALUMINUM ENTRANCES AND STOREFRONTS Aluminum entrance and storefront types required include: Exterior entrance doors. Vestibule doors matching entrance doors. Interior doors. Frames for exterior entrances. Frames for interior doors. Storefront type framing system. Performance Requirements: Provide certified test results showing systems have been tested by a recognized testing laboratory or agency with characteristics specified. Thermal Movement: Provide for expansion and contraction resulting from an ambient temperature range of 120 deg. F (67 deg. C) . Wind Loading: Withstand uniform test pressure of 20 psf inward and outward when tested in accordance with ASTM E 330. Fixed Framing Transmission Characteristics: Air Infiltration: Not more than 0.06 CFM per sq. ft. when tested in accordance with ASTM E 283 at an inward test pressure differential of 6.24 psf. Water Penetration: No penetration when tested in accordance with ASTM E 331 at an inward test pressure differential of 6.24 lbf per sq. ft. Condensation Resistance: Not less than 45 CRF when tested in accordance with AAMA 1502. Thermal Transmittance: Not more than 0.65 BUT/(hr. x sq. ft. x deg. F) at 15 mph wind velocity when tested in accordance with AAMA 1503. Aluminum Entrance Transmission Characteristics. Air Infiltration: Not more than 0.50 CFM for single doors and 1.0 for pairs of doors when tested in accordance with ASTM E 283 at an inward test pressure differential of 1.567 psf. Condensation Resistance: Not less than 48 CRF when tested in accordance with AAMA 1502. Thermal Transmittance: Overall U—value of not more than 0.93 BTU/(hr. x sq. ft. x deg. F) at 15 mph wind velocity when tested in accordance with AAMA 1503, Product Data: Include fabrication methods, accessories and installation recommendations. finishing, hardware, 8776/ALUMINUM ENTRANCES & STOREFRONTS RICKS COLLEGE/ PLANT SCIENCE REMODEL 08410 — 1 Shop Drawings: Include elevations, details, hardware mounting heights, anchorages, expansion provisions and glazing details. Samples: Pairs of each finish, on 12" long sections of extrusions and on 6" square sheets. Manufacturer's Qualifications: 5 years experience in fabrication. Installer's Qualifications: 5-years experience in installation. Design Criteria: Drawings are based on one manufacturer's system. Another manufacturer's system will be acceptable when differences do not detract from the design concept, as judged by Architect. Manufacturer: Provide products of one of the following: Amarlite/Arco Metals Co. Cronstroms Mfg. Inc. Guaranteed Products. Harcar Aluminum Products Co.. Kawneer Company, Inc. PPG Industries, Inc. Tajima, Inc. Tubel ite Div., Indal Inc. United States Aluminum Corp., International Alum. Corp. United States Metal and Manufacturing Corporation. Vistawall Architectural Products. Materials: Aluminum Members: Alloy and temper recommended for strength, corrosion resistance, and application of finish; comply with ASTM B 221 for extrusions and ASTM B 209 for sheet or plate. Fasteners: Aluminum, nonmagnetic stainless steel, or other noncorrosive material. Except for application of hardware, do not use exposed fas- teners. For hardware, use Phillips flat -head machine screws; match finish of member of hardware being fastened. Weatherstripping: Replaceable compressible neoprene or molded PVC type gaskets or replaceable wool, polypropylene, or nylon woven pile, with nylon fabric or aluminum strip backing as suitable for type of door operation. Glass and Glazing Materials: Comply with requirements of "Glass and Glazing" section of these specifications. Glazing Panels: Flush panels with resin -impregnated Kraft paper honeycomb or rigid closed -cell urethane core, laminated with waterproof glue between two sheets of aluminum. Storefront Framing: Inside -outside matched resilient flush -glazed framing with provisions for glass replacement. Shop -fabricate and preassemble. 8776/ALUMINUM ENTRANCES & STOREFRONTS 08410 - 2 RICKS COLLEGE/ PLANT SCIENCE REMODEL Stile -and -Rail Type Aluminum Doors: 1-3/4" thick; tubular frame members, with mechanical joints using heavy reinforcing plates and concealed tie -rods or i-bolts. Design: Medium stile (3-1/2" nominal width). Hardware: Provide- _heavy-duty units; finish to match door. Refer to hardware section for items not provided by the manufacturer. Offset Pivot Sets: Comply with ANSI A156.4; Grade 1 requirements; exposed parts of cast aluminum alloy. Surface -Mounted Overhead Closers: Modern type with cover. Comply with ANSI A156.4. Comply with recommendations for closer size. LCN 4041 DEL Series, or approved equivalent. Parallel arm type mounting, with hold -open device. Door Stop: Floor or wall mounted with integral rubber bumper; comply with ANSI A156.16. Cylinders are specified in the hardware section. F4gnip Hardware: Concealed -rod type actuated by full -width crash bar; comply with UL 305. At Contractor's option provide concealed -rod type device, complying with UL 305, with latch releasing mechanism recessed into crossrail and actuated by a push panel. Pull Handles: Aluminum handles of style indicated. Push Bars: Full door width single bar push bar. Thresholds: Extruded aluminum in mill finish, with anchors and clips, coordinated with pivots of manufacturer's standard. Fabrication: Sizes units and profile requirements, are indicated on drawings. Prefabrication: Before shipment, complete fabrication, assembly, finishing, hardware application, and other work to the greatest extent possible. Disassemble only for shipment and installation. Preglaze to greatest extent possible. Do not drill and tap for surface -mounted hardware until time of installation. Perform fabrication, including cutting, fitting, forming, drilling and grinding to prevent damage to exposed finish surfaces. For hardware, perform prior to application of finishes. 8776/ALUMINUM ENTRANCES & STOREFRONTS 08410 - 3 RICKS COLLEGE/ PLANT SCIENCE REMODEL Welding: Comply with AWS recommendations; grind exposed welds smooth and restore mechanical finish. � Dissimilar Metals: Separate dissimilar metals with zinc chromate primer, bituminous paint, or other separator. Continuity: Maintain accurate relation of planes and angles, with hairline fit of contacting members. i Provide neoprene silencers on stops at interior doors. Finishes: Color Anodized Finish: NAAMM AA—M12C22A41/A44, Class I. Color: medium bronze. Installation: Comply with manufacturer's instructions. Set units plumb, level, and true to line, without warp or rack of framing members, doors, or panels. Provide proper support and anchor securely in place. Separate aluminum and other corrodible metal surfaces from sources of corrosion at points of contact with other materials. Adjust operating hardware to function properly. Clean system promptly after installation. END OF SECTION 08410 8776/ALUMINUM ENTRANCES & STOREFRONTS 08410 — 4 RICKS COLLEGE/ PLANT SCIENCE REMODEL SECTION 08710 - FINISH HARDWARE General Hardware Reauirements: Number Designations: Numbers indicating hardware items are ANSI standard number designations. Acceptable Manufacturers/Products: Acceptable manufacturers for various types of products are listed below. An asterisk (*) following a manufacturers name designates manufacturer whose products are indicated in Finish Hardware Schedule. Such products are listed in the schedule by specific reference to manufacturers catalog numbers. Except as otherwise indicated, products of equivalent quality, design and function by other listed manufacturers may be used, subject to approval of Architect. Submit final hardware schedule organized by "hardware sets", to indicate specifically the product to be furnished for each item required on each door. Furnish templates to each fabricator of doors and frames, as required for preparation to receive hardware. For fire -rated openings provide hardware tested and listed by UL or FM (NFPA Standard 80). On panic exit devices, provide UL or FM label indicating "Fire Exit Hardware". Submit samples of hardware items, showing each required finish from each manufacturer (for acceptance of color and texture only). Finish and base material designations are indicated in accordance with ANSI A156.18 or the nearest traditional U.S. commercial finish. Where base material and quality of finish are not otherwise indicated, provide at least the commercially recognized quality specified in ANSI A156 series standards applicable to each particular type of hardware. Hinges and Pivots: Mfrs. of Butts: Stanley*, Hager, Lawrence, McKinney, Henry Soss. Provide full -mortise type hinges on each door, except as otherwise indicated, and except as otherwise needed for proper support and operation of doors. Provide stainless steel pins, except steel pins with steel hinges; non -removable for exterior and public interior exposure, non -rising for non -security exposure, flat button with matching plugs. Ball -bearing Function: Swaged, inner. leaf beveled, square corners. Locks, Latches and Bolts: 8776/FINISH HARDWARE 08710 - 1 RICKS COLLEGE/ PLANT SCIENCE REMODEL Mfr. of Lock/Latch Sets Including Cylinders: Schlage*. Mfr. of Combination Locking Device: Simplex*. Mfr. of Exit Devices: Von Dupr in*. Mfrs. of Door Bolts: Sargent*,Builders Brass Works, Ives, Russwin, Sargent, Stanley. Strikes: Wrought box strikes, with extended lip for latch bolts, except open strike plates may be used in wood frames. Provide dust -proof strikes for foot bolts. Eguiv exit devices with dogging devices where door has closer, except when door is fire -rated. Locks: Equip lock sets with 6-pin tumbler type lock cylinders, in a masterkey system, to be designated by Owner. Construction Locks: Either temporary cylinders for construction period, or temporary construction keying which is automatically voided through use of Owners' keys. Provide 3 change keys for each lock, plus 5 masterkeys for each master key system. Stamp keys "DO NOT DUPLICATE". Provide key control system, including metal cabinet with 150% capacity, envelopes, labels, tags, clips, forms, card index and markers; standard system with keys installed and index prepared by key control manufacturer. Push/Pull Units Mfrs. of Push/Pull Units: Triangle Brass*, Baldwin, Brookline, Builders Brass Works, Quality. Door Control Devices: Mfr. of Overhead Closers: LCN*. Mfrs. of Holders, Stops, Bumpers: Triangle Brass*, Brookline, Builders Brass Works, Quality, Sargent, Stanley. Provide grey rubber exposed resilient parts. Finish exposed metal to match hardware, except finish floor plates to match thresholds, terrazzo stripping or similar floor finish. Provide recessed plates, wherever possible, to receive insert of resilient floor finish. Size and mount units indicated or, if not indicated, to comply with mfrs.'s recommendations for the exposure condition. Reinforce the substrate as recommended. 8776/FINISH HARDWARE 08710 - RICKS COLLEGE/ PLANT SCIENCE REMODEL Where parallel -arm closers are indicated, provide units one size larger than recommended for standard -arm units. Provide silencers in metal door frames, unless not permitted for fire rating, or unless bumper -type weatherstripping is provided; 3 per single -door frame, 4 per double -door frame. Miscellaneous Door Hardware: Mfrs. of Miscellaneous Hardware: Provide plates, trim, or other units as indicated, produced by Builders Brass Works*, A-J Mfg. Co., Baldwin, Brookline, Cipco, Ives, Triangle Brass. Fabricate plates and edge trim units 1/16" to 1/2" smaller than actual door dimension. Install with self -tapping screws. Provide 1/8" thick brown plastic with beveled edges for kick elates. Weatherstripping: Mfrs of Weatherstripping: Pemko*, Liberty, National Guard, Reese, Zero. Provide manufacturer's standard weatherstripping of type, size and profile indicated, continuous at head and lamb edges of each exterior door opening. Provide non -corrosive fasteners. Thresholds: Mfrs. of Thresholds: Pemko*, National Guard, Reese, Zero. Provide extruded aluminum threshold of type, design and profile indicated, complete with replaceable resilient vinyl wiper -type insert. Provide non -corrosive fasteners. Installation: Hardware Mounting Heights: Door and Hardware Institute "Recommended Locations for Builders Hardware for Standard Steel Doors and Frames", except as otherwise indicated. Install each hardware item to comply with manufacturer's instructions and recommendations. Set thresholds for exterior doors in full bed of butyl -rubber or polvisobutylene mastic sealant. Remove excess sealant and clean adjacent surfaces. Hardware Adjustment: Return to project one month after Owner's occupancy, and adjust hardware for proper operation and function. Instruct Owner's personnel in proper maintenance and adjustment. 087 10 - 8776/FINISH HARDWARE RICKS COLLEGE/ PLANT SCIENCE REMODEL FINISH HARDWARE SCHEDULE Group 1 All hardware shall be furnished by door supplier. Group 2 1 1/2 Pr. FB13-179-26D 4 1/2" x 4 1/2" NRP Stanley. 1 Schlage Ply D80PD K & MK. 1 Set Code approved Smoke Gaskets. 3 Rubber Silencers. Group 3 1 1/2 Pr. FBB-179- 26D 4 1/2" x 4 1/2' NRP Stanlev. 1 Simplex Unican 1000-2. 1 Closer LCN-T-D 4040 90 Stop Arm. 1 Kick Plate 10" x 1/2" LTDW 1/8" Brown Plastic. 3 Rubber Silencers. Group 4 1 1/2 Pr. FBB-179-26D 4 1/2" x 4 1/2" NRP Stanley. 1 Schlage Ply D70PD K & MK. 1 Closer LCN-T-D 4040 90 Stop Arm. 1 Kick Plate 10" x 1/2" LTDW 1/8" Brown Plastic. 3 Rubber Silencers. Group 5 1 1/2 Pr. FBB-179-26D 4 1/2" x 4 1/2" NRP Stanley. 1 Schlage Ply D80FD K & MK. 3 Rubber Silencers. Group 6 1 1/2 Pr. FBB-179-26D 4 1/2" x 4 1/2" NRP Stanley. 1 Schlage Ply D50PD K & MK- 1 Closer LCN-T-D 4040 90 Stop Arm. 1 Kick Plate 10" x 1/2" LTDW 1/8" Brown Plastic. 3 Rubber Silencers. END OF SECTION 08710 8776/FINISH HARDWARE 08710 - 4 RICKS COLLEGE/ PLANT SCIENCE REMODEL SECTION 16800 _ AUXILIARY SYSTEMS FIRE ALARM EXPANSION Provide all the equipment, materials and labor necessary to expand the existing fire alarm system. The system addition shall be connected directly to the existing main fire alarm panel. The installation shall be as recommended by the manufacturer. When the system is complete, a factory representative shall test the system, make adjustments and place the system in operating order. The manufacturer of the existing equipment is Autocall. TELEVISION SYSTEM (CONDUIT ONLY) For the future installation of a centralized television system, provide a system of empty raceways and outlets as shown in the television system diagram on the drawings. Outlets shall consist of a standard 4" square box. The cover plate shall match the heretofore specified device plates. Leave a nylon pull cord in all empty raceways. The raceways shall be installed in compliance with the conduit specifications heretofore covered. STAND-BY SYSTEM EQUIPMENT The existing 30 KW 120/208 volt altered to accommodate a remote 3 phase ONAN generator shall be radiator. The electrical contractor shall remove the existing for radiator and install a remote radiator outside seeplans concrete pad as per Provide all necessary mounting equipment manufacturer's recommendations. The entire system shall be filled with anti -freeze coolant. Piping for cooling system is to be provided and installed by the mechanical contractor. ally The new remote riator ito be tors #2P 4-ls 5 (H4 ) ser iz tmounted, such as Bearward Radia esH with 1 1/ 2 HP208 volt 3-pole race motor and surge tank. 16/54 8776/Division 16 Ricks College Plant Science Basement Remodel SECTION 16744 - COMPUTER SYSTEM & INDICATED CLOCKS: COMPUTER SYSTEM: Install conduit as required, 3/4" minimum size, for the installation of a computer system as per the drawings. The equipment shall be by others. Coordinate rough -in with the equipment supplier. Provide boxes and coverplates. Confirm location of all outlets with owner before rough -in. INDICATING CLOCKS: All clocks shall be flush 12" round. Clock shall be Simplex #76- 45 and shall be compatible with the existing superimposed signal system on campus. The Electrical Contractor shall include in his bid all necessary equipment, labor, etc. to tie into this existing Simplex System. END OF SECTION 16744 8776/Division 16 16/53 Ricks College Plant Science Basement Remodel SECTION 16740 _ TELEPHONE SYSTEM (RACEWAYS) PART 1 - GENERAL DESCRIPTION OF WORK: Extent of telephone system work is indicated by drawings and is hereby defined to include, but not be limited to raceway outlets, device plates, backboards, cabinets, grounding and miscellaneous items required for complete raceway system. Refer to other Division-16 sections for requirements for raceways, trays, boxes and fittings, wiring devices (plates), and supporting devices, and other sections, as applicable. QUALITY ASSURANCE: Comply with applicable portions of NEC as to type of products used and installation of components. Provide products and materials which have been UL-listed and labeled. PART 2 - PRODUCTS GENERAL: Provide compete raceway system for telephone including but not limited to, raceway, outlets, device plates, backboards, cabinets, grounding and miscellaneous items as required. Provide telephone coverplates for wall outlets to match color and material of wiring device plates; for floor outlets, match color and material of floor power outlet covers. PART 3 - EXECUTION INSTALLATION OF TELEPHONE RACEWAY SYSTEM: GENERAL: Install raceway system as indicated to comply with NEC and recognized industry practices. Run 3/4" conduit from each telephone outlet to terminal backboard, tray, or terminal cabinet. Provide nylon pull cord in all installed raceway. END OF SECTION 16740 8776/Division 16 16/52 Ricks College Plant Science Basement Remodel backing supports above (or behind) sheetrock, plaster and similar ceiling and wall materials. Support ceiling mounted outlet boxes independent of the raceway system, and capable of supporting 200 pounds. See plans for additional details. ADJUST AND CLEAN: Clean lighting fixtures of dirt and debris upon completion of installation. Protect installed fixtures from damage during remainder of construction period. Repair all necks and scratches to appearance of original finish. FIELD QUALITY CONTROL: Upon completion of installation of lighting fixtures, and after building circuitry has been energized, apply electrical energy to demonstrate capability and compliance with requirements. Where possible, correct malfunctioning units at site, then reset to demonstrate compliance; otherwise remove and replace with new units, and proceed with retesting. At the time of Substantial Completion, replace lamps in interior lighting fixtures which are observed to be noticeably dimmed after the Contractor's use and testing, as judged by Architect/Engineer. In addition, furnish stock or replacement lamps amounting to 15 percent (but not less than one lamp) of each type and size used. (Max. 48 of any one type.) Deliver replacement stock with letter of transmittal as directed to Owner's storage space. GROUNDING: Provide tight equipment grounding connections for each lighting fixture. END OF SECTION 16510 8776/Division 16 16/51 Ricks College Plant Science Basement Remodel Equip outdoor fixtures with low temperature starting ballasts. HARGE-LAMP BALLASTS: Provide l mmanufacturer,facture ID Of HIGH-INTENSITY-DISCr, ratings, types and makes as recommended by yroviding appropriate which properly match lamps to power line by p . Equip voltage and impedances for which lamps a restarting designed ballasts• exterior fixtures with low pfactor improved ballasts. Provide high power factor, or power FLUORESCENT LAMPS: Equip interior fluorescent fixtures with full light output, energy conserving lamps where available as standard product of General Electric, Sylvania, or Westinghouse. Where applicable, equip fixtures with lamps as follows: 3050 initial lumens Rapid Start 000 initial lumens 6 Slimline 0 00 initial lumens High Output General Electric Watt Miser II, Sylvania Supersaver II, Westinghouse Econ-o-Watt. Equip exterior fixtures with standard lamps. plastic diffusers are specified, provide 100 DIFFUSERS: Where p .125 inches. percent virgin acrylic compound; minimum thickness, Provide a spare set of diffusers (acrylic and/or glass) for each fixture type and one foreach res foraanytional 10 sifixtures of each single fixturetype type; not to exceed 10 spa PART 3 - EXECUTION INSTALLATION OF LIGHTING FIXTURES: Install lighting fixtures at re manufacturerns written instructions, in accordance wltuifixtu s of NEC, NECA's "Standard of applicable req standards, and with recognized Installation", NEMA eq fulfill rrements. practices to ensure that lightingfixtures Coordinate with other work as appropriate to properly interface installation of lighting fixtures with other work. Consult architectural reflected ceiling plan for exact location of all lighting fixtures. supports, brackets, and miscellaneous Provide all necessary equipment for mounting of fi��ucture,Sinndependentport all coflthe ceiling fixtures from the building s system, unless noted. Support each recessed fixture (fluorescent incandescent, and/or HID) from the building structure with #8ogis steel wire attachede(in addition sProvide normally provided for atta hment to the ceiling system). 16/50 8776/Division 16 Ricks College Plant Science Basement Remodel INCANDESCENT AND FLUORESCENT LAMPS: General Electric Co. Sylvania Lamp Div., GTE Corp. Westinghouse Corp. HID LAMPS General Electric Co. Sylvania Lamp Div., GTE Corp. INTERIOR AND EXTERIOR LIGHTING FIXTURES: GENERAL: Provide lighting fixtures, of sizes t indicated complete with ypeS and ratings housings, lamps, but not necessarily limited to, and wirin P , lamp holders, reflectors, ballasts, starters 9• Label each fixture with manufacturer's name and catalog number. Provide all enclosed fixtures with latch mechanisms; spring tension clips not Positive all exterior fixtures with dam P acceptable. Provide by application. P or wet location label as required SUPPORT REQUIREMENTS: Provide all pendant and stem hung fixtures with flexible ball joint hangers at all points of support. hooks used to hang fixtures with safety Equip detachable fixture arts latches. Provide all diffusers P luminous ceiling accessories, louvers, lenses, and reflectors with lockin safety chain or safety cable. 9 catches, screws, Each hanger point shall be capable of su fixture weight. Backin PPorting four times the behind) sght. Backing aster supports shall be installed above (or materials. Plaster and similar ceiling and wall All surface mounted ceiling fixtures shall be supported from a structural channel. details. See plans for additional FLUORESCENT -LAMP BALLASTS: Provide fluorescent -lamp ballasts, capable of operating lamp types indicated; with high factor, and low -noise features, Class psound-Power ratA, and with internal thermal protection. See plans forvoltageerrequirements. For interior fixtures, provide full conserving ballasts where light output energy follows: available as standard products, as Advance Transformer Co. - Mark III Series General Electric Co. - Maxi -Miser II Series Universal Mfg. Co. - SLH-Watt Reducer Series Comply with manufacturer's written recommendations for all lamp/ballast combinations. 8776/Division 16 Ricks College Plant Science Basement Remodel 16/49 SECTION 16510 - INTERIOR AND EXTERIOR BUILDING LIGHTING PART 1 _ GENE DESCRIPTION OF WORK: Extent of interior and exteriolighting fixture work is indicated by drawings and schedules Types of lighting fixtures in this section include the following: High -Intensity -Discharge (HID) Fluorescent Incandescent QUALITY ASSURANCE: with NEC, NEMA and ANSI 132.1 as applicable to Comply with installation and constructcessed ion of lighting fixtures. Comply NEC 410-64C iriorall t which have beeneULelistedght and labeled. Provide lighting fixtures CBM LABELS: Provide fluorescent -lamp ballasts which comply with Certified Ballast Manufacturer's Association standards and carry the CBM label. SUBMITTALS: PRODUCT DATA: Submit manufacturer's data on interior and exterior building lighting fixtures. SHOP DRAWINGS: Submit dimensioned drawings of lighting fixtures. Submit fixture shop drawings in booklet form with separate sheet for each fixture, assembled in luminaire "type" alp habetical order, with proposed fixture and accessories clearly indicated on each sheet. PART 2 _ PRODUCTS ACCEPTABLE MANUFACTURERS: Subject to compliance with requirements, provide products of one of the following (for each type of fixture): FLUORESCENT AND HIS BALLASTS: Advance Transformer Co. General Electric Co. Universal Mfg. Co. 16/48 8776/Division 16 Ricks College Plant Science Basement Remodel conductors for grounding connections matching power supply wiring materials and sized according to NEC. GROUND RODS AND PLATES: GROUND RODS: Steel with copper welded exterior, 5/8" dia. x 8 ft. PART 3 - EXECUTION INSTALLATION OF GROUNDING SYSTEMS: Install electrical grounding systems in accordance with manufacturer's written instructions and with recognized industry practices to ensure grounding devices comply with requirements. Install braided type bonding jumpers with ground clamps on water meter piping to electrically bypass water meter. Install clamp -on connectors only thoroughly cleaned and metal contact surfaces, to ensure electrical conductivity and circuit integrity. Provide grounding for the entire raceway, enclosure, equipment and device system in accordance with NEC. All non-metallic raceways shall include copper grounding conductor sized in accordance with NEC. Provide service entrance grounding by means of ground rods (quantity of two, driven exterior to building), by means of bonding to water main, and by means of bonding to building structural steel. In addition to all cold water and ground rods provided to meet this specification, each location grounded either to cold water or to a ground rod shall have a UFER ground. A UFER ground shall consist of a minimum of 25 feet of No 2/0 AWG bare copper cable embedded in concrete (feeder encasement, footing, floor slab, etc.) so that all portions of the cable are between 2" and 4" from the earth and with the center of the cable bonded to the ground rod or pipe. Provide grounding conductors for dimming systems in accordance with manufacturer's requirement. See drawings for additional grounding requirements. END OF SECTION 16452 8776/Division 16 16/47 Ricks College Plant Science Basement Remodel SECTION 16452 - GROUNDING DESCRIPTION OF WORK: Provide grounding as specified herein, and as indicated on drawings. Types of grounding in this section include the following: Underground metal water piping Grounding electrodes Grounding rods Separately derived systems Enclosures Systems Equipment Other items indicated on drawings Requirements of this section apply to electrical grounding work specified elsewhere in these specifications. QUALITY ASSURANCE: Comply with NEC as applicable to electrical grounding and ground fault protection systems. Comply with applicable ANSI and IEEE requirements. Provide products which have been UL listed and labeled. SUBMITTALS: None required. PART 2 - PRODUCTS GROUNDING: MATERIALS AND COMPONENTS: GENERAL: Except as otherwise indicated, provide each electrical grounding system as specified herein, and as shown on drawings, including but not necessarily limited to, cables/wires, connectors, terminals (solderless lugs), grounding rods/electrodes and plate electrodes, bonding jumper braid, and other items and accessories needed for complete installation. Where materials or components are not otherwise indicated, comply with NEC, NEMA and established industry standards for applications indicated. ELECTRICAL GROUNDING CONDUCTORS: Unless otherwise indicated, provide electrical grounding 8776/Division 16 16/46 Ricks College Plant Science Basement Remodel PART 3 - EXECUTION INSTALLATION OF OVERCURRENT PROTECTIVE DEVICES: Install overcurrent protective devices as indicated, in accordance with the manufacturer's written instructions and with recognized industry practices to ensure that protective devices comply with requirements. Comply with NEC and NEMA standards for installation of overcurrent protective devices. Coordinate with other work as necessary to interface installation of overcurrent protective devices with other work. Set field -adjustable circuit breakers for trip settings as indicated, subsequent to installation of devices. Install fuses in overcurrent protective devices. Field test all ground fault protective devices for proper operation; test to be performed by representative of the manufacturer. Include verification of complete time current trip characteristics. FIELD QUALITY CONTROL: Prior to energization of overcurrent protective devices, test devices for continuity of circuitry and for short-circuits. Correct malfunctioning units, and then demonstrate compliance with requirements. END OF SECTION 16180 8776/Division 16 16/45 Ricks College Plant Science Basement Remodel MOLDED CASE CIRCUIT BREAKERS: Provided factory -assembler, molded case circuit breakers for power distribution panelboards and switchboards; and for individual mounting, as indicated. Provide breakers and amperage, voltage and RMS interrupting rating shown, with permanent thermal trip and adjustable instantaneous magnetic trip in each pole. Construct breakers for mounting and operating in any physical position and in an ambient temperature of 40 degrees C. Provide with mechanical screw type removable connector lugs, AL/CU rated. All breakers in the main distribution panel shall have sufficient interrupting capacity to safely interrupt the available short circuit current from the transformer bank. Circuit breakers shall be Square "D", Type FH, KH, LH, MH, or as noted on the plans. ACCEPTABLE MANUFACTURER: Subject to compliance with requirements, provide ground -fault sensing and relaying equipment of one of the following: Square D Co. FUSES: GENERAL: Except as otherwise indicated, provide fuses of types, sizes and ratings and electrical characteristics as follows. Provide fuses labeled UL Class L or UL Class R, current limiting and rated for up to 200,000 amperes. MAIN SERVICE AND FEEDER CIRCUIT: For fuse ratings over 600 amperes provide UL Class L Fuses (KTU) . For fuse ratings up to 600 amperes, provide UL Class RK1 (LPN-RK, LPS-RK). If fuse directly feeds motor or transformers, provide UL RK1 time delay. BRANCH CIRCUITS: For motor circuits and transformer circuits, provide UL Class RK5 (FRN, FRS). For other circuits, provide UL Class RK5, non -time delay (LPN, LPS). MANUFACTURER: Subject to compliance with requirements, provide fuses of one of the following: Bussman Mfg. Co. Gould, Inc. SPARE FUSES: Provide one spare set of fuses for each size and one spare set for each additional group of five. 8776/Division 16 16/44 Ricks College Plant Science Basement Remodel SECTION 16180 - OVERCURRENT PROTECTIVE DEVICES PART 1 - GENERAL DESCRIPTION OF WORK: Extent of overcurrent protective device work is indicted by drawings and schedules. Overcurrent protective devices specified herein are for installation as individual components in separate enclosures; and for installation as integral components of switchboards and panelboards. See Section 16182, Switchgear and Switchboards, and Section 16160, Panelboards. Types of overcurrent protective devices in this section include the following for operation at 600 volts and above: - Molded cases circuit breakers - Power circuit breakers - Molded case systems breakers - Fuses Refer to other Division-16 sections for cable/wire and connector work required in conjunction with overcurrent protective devices. QUALITY ASSURANCE: Comply with NEC requirements and NEMA an ANSI standards as applicable to construction and installation of overcurrent protective devices. SUBMITTALS: PRODUCT DATA: Submit manufacturer's data on overcurrent protective devices, including catalog cuts, time -current trip characteristic curves, and mounting requirements. SHOP DRAWINGS: Submit layout drawings of overcurrent protective devices, with layout of circuit breakers, including special relationships to proximate equipment. MAINTENANCE STOCK, FUSES: For types and ratings required, furnish additional fuses, amounting to one unit for every 5 installed units, but not less than two units of each size and type. PART 2 - PRODUCTS CIRCUIT BREAKERS AND FUSIBLE SWITCHES: Square D. Co. 8776/Division 16 16/43 Ricks College Plant Science Basement Remodel FUSES: Provide fuses for switches, as required of classes, types and ratings needed to fulfill electrical requirements for services indicated. Provide spare fuses amounting to one spare fuse for each 10 installed but not less than three of any one type and size. See Section 16180 Overcurrent Protective Devices for fuse types. PART 3 - EXECUTION INSTALLATION OF MOTOR AND CIRCUIT DISCONNECT SWITCHES: Install motor and circuit disconnect switches where indicated, complying with manufacturer's written instructions, applicable requirements of NEC, NECA's "Standard of Installation" and in accordance with recognized industry practices to ensure that products fulfill requirement. Coordinate motor and circuit disconnect switch installation work with electrical raceway and cable work, as necessary for proper interface. Install disconnect switches with motor drive appliances, and motors and controllers within sight of controller position. END OF SECTION 16170 8776/Division 16 16/42 Ricks College Plant Science Basement Remodel SECTION 16170 - MOTOR AND CIRCUIT DISCONNECTS PART 1 - GENERAL DESCRIPTION OF WORK: Extent of motor and circuit disconnect switch work is indicated by drawings and schedules. Work includes complete installation and electrical connections. QUALITY ASSURANCE: Provide motor and circuit disconnect switches which have been UL listed and labeled. Comply with applicable requirements of NEMA Standards Pub. No. KS 1, and NEC. SUBMITTALS: PRODUCT DATA: Submit manufacturer's data including specification, installation instructions and general recommendations, for each type of motor and circuit disconnect switch required. PART 2 - PRODUCTS ACCEPTABLE MANUFACTURERS: MANUFACTURER: Subjects to compliance with requirements, provide products of one of the following (for each type of switch): Square D Company FABRICATED SWITCHES: GENERAL: Provide disconnect and safety switches as indicated herein. Provide: - General duty switches on 240 volt rated circuits. - HP rated switches on all motor circuits. GENERAL DUTY SWITCHES: Provide general -duty type, sheet -steel enclosed switches, fusible or non -fusible as indicated of types, sizes and electrical characteristics indicated; rated 240 volts, 60 hertz; incorporating spring assisted, quick -make, quick -break switches which are so constructed that switch blades are visible in OFF position with door open. Provide single phase or three phase with solid neutral as required by applications. Equip with operating handle which is capable of being padlocked in OFF position. Provide NEMA 1 or NEMA 3R as required by application, unless noted. Provide fusible switches with Class R rejection fuse clip kits. 8776/Division 16 16/41 Ricks College Plant Science Basement Remodel mechanically secure. Arrange conductors neatly within enclosure, and secure with suitable nylon ties. Fill out panelboard's circuit directory card upon completion of installation work. Utilize actual final building room numbers, not architectural numbers used on drawings. Identify individual lighting circuits and individual receptacle circuits by room served. Include room number with equipment circuit designations. All directories to be typewritten. END OF SECTION 16160 8776/Division 16 16/40 Ricks College Plant Science Basement Remodel switch panel or as indicated on the plans. The meters shall be the dampened type as manufactured by Square "D". PANELBOARDS: GENERAL: Except as otherwise indicated, provide panelboards, enclosures and auxiliary components, of types, sizes, and ratings indicated. Equip with number of unit panelboard devices as required for complete installation. Fully equip "spaces" with hardware to receive breaker or switch of size indicated. LIGHTING AND APPLIANCE PANELBOARDS: Provide dead -front safety type lighting and appliance panelboards as indicated, with switching and protective devices in quantities, ratings, types and arrangement shown. provide bolt -on thermal magnetic type branch breakers. Where multiple breakers are indicated, provide with common trip handle. Equip with aluminum bus bars full-sized neutral bus, and ground bus. PANELBOARD ENCLOSURES: Provide galvanized sheet steel cabinet type enclosures, in sizes and NEMA types as indicated, code -gage minimum 16-gage thickness. Provide fronts with adjustable indicating trim clamps, and doors with flush locks and keys, all panelboard enclosures keyed alike, with concealed door hinges and door swings as indicated. Equip with interior circuit -directory frame, and card with clear plastic covering. Provide baked gray enamel finish over a rust inhibitor. Provide enclosures fabricated by same manufacturer as overcurrent devices contained therein. Bolt engraved formica labels indicating panel name and voltage on the interior and exterior of panelboards. FINISH: Coat interior and exterior of surface with manufacturer's standard color; baked on enamel finish. IDENTIFICATION: Provide 1/16" thick black formica labels with 1/4" high lettering on the interior and exterior of each panelboard; include panelboard name and voltage. PART 3 - EXECUTION INSTALLATION OF PANELBOARDS: GENERAL: Install panelboards and enclosures where indicated, in accordance with manufacturer's written instructions, applicable requirements of NEC and NECA's "Standard of Installation", in compliance with recognized industry practices to ensure products fulfill requirements. Coordinate installation of panelboards and enclosures with cable and raceway installation work. Anchor enclosures firmly to walls and structural surfaces, ensuring they are permanently and 8776/Division 16 16/39 Ricks College Plant Science Basement Remodel SECTION 16160 - PANELBOARDS PART 1 - GENERAL DESCRIPTION OF WORK: Extent of panelboard and enclosure work, is indicated by drawings and schedules. Types of panelboards and enclosures in this section include lighting and appliance panelboards, and power distribution panelboards. QUALITY ASSURANCE: Provide units which have been UL listed and labeled. Comply with NEC as applicable to installation of panelboards, cabinets, and cutout boxes. Comply with NEC pertaining to installation of wiring and equipment in hazardous locations. Comply with NEMA Stds. Pub. No. 250, "Enclosures for Electrical Equipment (1000 volt maximum)". Pub. No. 1, "Instructions for Safe Installation, Operation and Maintenance of Panelboards Rated 600 Volts or Less". SUBMITTALS: PRODUCT DATA: Submit manufacturer data including specifications, installation instructions and general recommendations, for each type of panelboard required. SHOP DRAWINGS: Submit dimensioned drawings of panelboards and enclosures showing accurately scaled layouts of enclosures and required individual panelboard devices, including but not necessarily limited to, circuit breakers, fusible switches, fuses, ground -fault circuit interrupters, and accessories. PART 2 - PRODUCTS ACCEPTABLE MANUFACTURERS: MANUFACTURERS: Subject to compliance with requirements, provide products of one General Electric Company. MFTF.RTNC, Provide and install the meter C.T.'s selector switches, wiring, etc., for installation of a complete metering system. Indicating meters (CLE) shall read voltage between phases and to neutral, line current and a totaling watt hour meter with a 15 minute demand with bridge test shunt switches. The metering system shall be sized so full scale is 80% of the Main Switch capacity. All the equipment and meters shall be incorporated in the main 8776/Division 16 16/38 Ricks College Plant Science Basement Remodel pole, 600 volts max with non -reversing magnetic starters as specified herein; in common cubicle or enclosure with motor circuit protector. Provide instantaneous trip circuit breaker as indicated and adjust to comply with manufacturer's recommendations. Provide combination starters for individual mounting, or for group mounting in motor control center as indicated. Provide NEMA 1 enclosures unless otherwise indicated. AC COMBINATION NON -REVERSING MAGNETIC STARTERS (EQUAL TO SQUARE D CLASS 8539): Provide line voltage combination starters, of types, ratings, and electrical characteristics; 2 or 3 pole, 600 volt maximum with non -reversing magnetic starters as specified herein; in common cubicle or enclosure with fusible disconnect switch. Provide quick -make, quick -break, visible blade disconnect switch. Provide 2, 3, and 4; and visible blade, automatic circuit interrupters with push -to -trip feature and separate fuse clips for larger NEMA sizes. Fuse all starters with dual -element (time -delay) fuses equal to Bussman FRN/FRS. Provide combination starters for individual mounting, or for group mounting in motor control centers as indicated. Provide NEMA 1 enclosures unless otherwise indicated. PART 3 - EXECUTION INSTALLATION OF MOTOR STARTERS: Install motor starters as indicated, in accordance with manufacturer's written instructions, applicable requirements of NEC, NEMA standards, and NECA's "Standards of Installation", and in compliance with recognized industry practices to ensure that products fulfill requirements. Install fuses in fusible disconnects, if any. ADJUST AND CLEAN: Inspect operating mechanisms for malfunctioning and, where necessary, adjust units for free mechanical movement. Touch-up scratched or marred surfaces to match original finish. FIELD QUALITY CONTROL: Subsequent to wire/cable hook-up, energize motor starters and demonstrate functioning of equipment in accordance with requirements. END OF SECTION 16155 8776/Division 16 16/37 Ricks College Plant Science Basement Remodel characteristics indicated which comply with manufacturer's standard materials, design and construction in accordance with published information, and as required for complete installations. THERMAL OVERLOAD UNITS: Provide thermal overload units, sized in accordance with manufacturer's recommendations for full load current of motor controlled. Provide thermal heater units, sized to actual running full load current if actual full load current is less than 90 percent of motor nameplate full load current. Size heater for mechanical equipment after air and water balancing have been completed. Spare parts: Provide a spare set of each type and/or size. AC FRACTIONAL HP MANUAL STARTERS (EQUAL TO SQUARE D CLASS 2510): Provide manual, single-phase, 1 and 2 pole, 300 volt AC max, fractional HP motor starters, of types, ratings and electrical characteristics indicated; equip with one piece thermal overload relay with field adjustment capability of plus or minus 10 percent of nominal overload heater rating; for protection of AC motors of 1 HP and less. (For manually controlled motors in excess of 1 HP, see Line Voltage Manual Starters specified herein.) Provide starter with quick -make, quick -break trip free toggle mechanisms, green pilot lights, and with lock -off toggle operated handle. Mount surface units in NEMA 1 enclosures, unless noted otherwise. Provide flush mounted units with coverplate to match wiring device coverplates. AC LINE VOLTAGE MANUAL STARTERS (EQUAL TO SQUARE D CLASS 2510): Provide line voltage manual starters, of types, ratings and electrical characteristics indicated, 2 or 3 pole, 600 volt AC max, equip with pushbutton operator, low voltage protection feature, and green pilot light. Provide starters with trip free mechanism such that contacts will open under load and remain open until thermal element has cooled, and unit is reset. Mount surface units in NEMA 1 enclosure, unless noted otherwise. Provide overlapping trim for flush mounted units. AC NON -REVERSING MAGNETIC STARTERS (EQUAL TO SQUARE D CLASS 2510): Provide line voltage magnetic starters, to types, ratings and electrical characteristics indicated, 2 or 3 pole, 600 volt max, with thermal overload protection and under voltage trip in all phases. Equip units with holding contact, 2 normally open, and 2 normally closed auxiliary contacts, unless noted otherwise. Provide fused control transformer in each starter. Mount hand- off -auto switch, red pilot light, and reset button in face of enclosure. Provide NEMA 1 enclosure unless noted otherwise. Equip all spare starters complete with items as specified herein. AC COMBINATION NON -REVERSING MAGNETIC STARTERS (EQUAL TO SQUARE D CLASS 8538): Provide line voltage combination starters, of types, ratings and electrical characteristics indicated; 2 or 3 8776/Division 16 16/36 Ricks College Plant Science Basement Remodel SECTION 16155 - MOTOR STARTERS PART 1 - GENERAL DESCRIPTION OF WORK: Extent of motor starter work is indicated by drawings and schedules. Types of motor starter in this section include the following: AC Fraction horsepower Manual Starters AC Line Voltage Manual Starters AC Non -Reversing Magnetic Starters AC Combination Non -Reversing Magnetic Starters QUALITY ASSURANCE: Comply with NEC and NEMA Standards as applicable to wiring methods, construction and installation of motor starters. Comply with applicable requirements of UL 508, "Electric Industrial Control Equipment", pertaining to electrical motor starters. Provide units which have been UL-listed and labeled. SUBMITTALS: PRODUCT DATA: Submit dimensioned drawings of motor starters showing accurately scaled equipment layouts. MOTOR VOLTAGE/CURRENT REPORT: After installation is complete, including water and air balancing, measure voltage (L-L and L-N) and full load current of each phase of each motor. Submit report showing field readings of voltage and amperage and thermal heater size installed for each motor. PART 2 - PRODUCTS MANUFACTURER: Subject to compliance with requirements, provide products of one of the following (for each type and rating of motor starter): Square D Co. MAINTENANCE STOCK, FUSES: For types and ratings required, furnish additional fuses, amounting to one unit for every 10 installed units, but not more than 5 units of each type, for both power and control circuit fuses. MOTOR STARTERS: GENERAL: Except as otherwise indicated, provide motor starters and ancillary components; of types, sizes, ratings and electrical 8776/Division 16 16/35 Ricks College Plant Science Basement Remodel PART 3 - EXECUTION Install wiring devices as indicated, in compliance with manufacturer's written instructions, applicable requirements of NEC and NECA's "Standard of Installation" and in accordance with recognized industry practices to fulfill project requirements. Coordinate with other work, including painting, electrical box and wiring work, as necessary to interface installation of wiring devices with other work. Install devices in boxes such that front of device is flush and square with coverplate. Drawings are small scale and, unless dimensioned, indicate approximate locations only of outlets, devices, equipment, etc. Locate outlets and apparatus symmetrically on floors, walls and ceilings where not dimensioned and coordinated with other work. Verify all dimensioned items on job site. Consult architectural cabinet, millwork, and equipment shop drawings before beginning rough -in of electrical work. Adjust wiring devices only in electrical boxes which are clean; free from excess building materials, dirt, and debris. Mark each with felt tip marker, indicating the circuit to which the device is connected. Example: "CKT A-1". Install blank plates on all boxes without devices. Delay installation of wiring devices until wiring work is completed. Delay installation of wall plates until after painting work is completed. Provide separate neutral conductors from panel to each GFI receptacle. PROTECTION OF WALL PLATES AND RECEPTACLES: At time of substantial completion, replace those items which have been damaged, including those stained, burned and scored. GROUNDING: Provide electrical continuous, tight grounding connections for wiring devices, unless otherwise indicated. TESTING: Prior to energizing circuitry, test wiring devices for electrical continuity and proper polarity connections. After energizing circuitry, test wiring devices to demonstrate compliance with requirements. END OF SECTION 16140 8776/Division 16 16/34 Ricks College Plant Science Basement Remodel Coverplates: All devices to have matching coverplates. All coverplates to be impact resistant and shall be constructed of nylon or lexon. Special devices as indicated on the plans, complete with matching coverplates shall be provided and installed where designated on the drawings. Provide devices in colors selected by Architect. CORDS CAPS AND CONNECTORS: Provide 3-wire grounding, cap plugs, and connectors of ampere and voltage rating required, for final equipment connection, and as indicated otherwise on drawings. Provide products of one of the following: Arrow Hart General Electric Hubbell Leviton Pass and Seymour INCANDESCENT LAMP DIMMERS: Provide branch lighting solid-state AC dimmer controls for incandescent fixtures; wattage and voltage as indicated, 60 hertz, with continuously adjustable slider control. Provide dimmers manufacturer by Lutron. Color as selected by Architect. FLUORESCENT LAMP DIMMERS: Provide single -pole, semi -conductor modular type AC dimmers for fluorescent fixtures; 60 hertz, with wattage and voltage as indicated, continuously adjustable slider control, and with electromagnetic filters to reduce noise and interference to minimum. Construct with continuously adjustable trim potentiometer for adjustment of low and dimming. Provide dimmer manufactured by Lutron. Color as selected by Architect. WIRING DEVICE ACCESSORIES: WALL PLATES: Provide coverplates for wiring devices; plate color to match wiring devices to which attached. Provide matching nylon Lexan coverplates in all finished areas. Provide galvanized steel plates in unfinished areas. Engrave all receptacle plates other than those serving 120 volt, single phase devices. State voltage and amperage characteristics. Example: 208V, 30A". All switch banks shall have each switch identified as to its function with micarta engraved adhesive backed plate. Emergency power coverplate shall be "RED", engrave name "Emergency Power". 8776/Division 16 16/33 Ricks College Plant Science Basement Remodel SECTION 16140 - WIRING DEVICES PART 1 - GENERAL DESCRIPTION OF WORK: The extent of wiring device work is indicated by drawings and schedules. Wiring devices are defined as single discrete units of electrical distribution systems which are intended to carry but not utilize electric energy. Types of electrical wiring devices in this section include the following: Receptacles Switches Coverplates Dimmer controls Cord caps Cord connectors QUALITY ASSURANCE: Comply with NEC and NEMA standards as applicable to construction and installation of electrical wiring devices. Provide electrical wiring devices which have been UL listed and labeled. SUBMITTALS: PRODUCT DATA: Submit manufacturer's data on electrical wiring devices. PART 2 - PRODUCTS FABRICATED WIRING DEVICES: GENERAL: Provide factory -fabricated wiring devices, in types, and electrical ratings for applications indicated and complying with NEMA Stds. Pub. No. WD 1. Provide wiring devices (of proper voltage rating) as follows: MFGR. C.O.'S 1-POLE 3-WAY 4-WAY W-PILOT Hubbell 5362 I 1221 I 1223 I 1234 I P& S 5362 I 20ACI I 20AC3 I 20AC4 I Leviton 5362 I 1223 I 1223 I 1224 I Slater 5362G I 720 I 723 I 724 I Sylvania 5362 I 1221A I 1221A I 1224A I Arrowhart 5362 I 1991 I 1993 I 1994 I 8776/Division 16 Ricks College Plant Science Basement Remodel 1221-Pl I 20ACI-CPL 720-Pl I 1271-RD I 1991-IL 7 16/32 of parallel runs of horizontal conduits to be supported together on trapeze type hangers where possible. RACEWAYS: Support raceways which are rigidly attached to structure at intervals not to exceed 8 feet on center and within 12" of each junction box, outlet or fitting. Support raceway (as it is installed) in accordance with the following: NUMBER OF RUNS 3/4" TO 1-1/2" 0 1 Full straps, clamps or hangers. 2 Full straps, clamps or hangers. 3 Mounting Channel 1-1/2" & LARGER 0 Hanger Mounting Channel Mounting Channel Support suspended raceways on trapeze hanger system, or individually by means of threaded rod and straps, clamps, or hangers suitable for the application. Do not use "tie wire" as a portion of any raceway support system; do not support raceway from ceiling support wires. FLOOR MOUNTED EQUIPMENT: Provide rigid attachment of all floor mounted equipment to the floor slab or structural system. Provide 5/8" bolts or expansion anchors at each 90 degrees corner and at intervals not to exceed 48" on center along entire perimeter of the equipment. Provide rigid attachment for all floor mounted switchboards, panelboards, power and control equipment, motor control centers, dimmer cabinets, transformers, oil switches, battery packs and racks, and similar equipment furnished under Section 16. END OF SECTION 16136 8776/Division 16 16/31 Ricks College Plant Science Basement Remodel SECTION 16136 - SUPPORTING DEVICES PART 1 - GENERAL DESCRIPTION OF WORK: Extent of supports, anchors, and sleeves is indicated by drawings and schedules and/or specified in other Division-16 sections. See Section 16110, Raceways, for additional requirements. Work of this section includes supports, anchors, sleeves, and seals required for a complete raceway support system, including but not limited to: clevis hangers, riser clamps, C-clamps, beam clamps, one and two hold conduit straps, offset conduit clamps, expansion anchors, toggle bolts, threaded rods, U-channel strut systems, and all associated accessories. QUALITY ASSURANCE: Comply with NEC as applicable to construction and installation of electrical supporting devices. Comply with applicable requirements of ANSI/NEMA Std. Pub. No. FB 1, "Fittings and Supports for Conduit and Cable Assemblies". Provide electrical components which are UL-listed and labeled. PART 2 - PRODUCTS MANUFACTURED SUPPORTING DEVICES: GENERAL: Provide supporting devices; complying with manufacturer's standard materials, design and construction in accordance with published product information, and as required for a complete installation; and as herein specified. See drawings for additional requirements. PART 3 - EXECUTION INSTALLATION OF SUPPORTING DEVICES: Install hangers, anchors, sleeves, and seals as required, in accordance with manufacturer's written instructions and with recognized industry practices to insure supporting devices comply with requirements. Comply with requirements of NECA, NEC and ANSI/NEMA for installation of supporting devices. Coordinate with other electrical work, including raceway and wiring work, as necessary to interface installation of supporting devices with other work. Install hangers, supports, clamps and attachments to support piping properly from building structures. Arrange for grouping 8776/Division 16 16/30 Ricks College Plant Science Basement Remodel sets on the box mounting plate. This will cause the device and coverplate surfaces to match. Fasten boxes rigidly to substrates or structural surfaces to which attached, or solidly embed electrical boxes in concrete or masonry. Use bar hangers for stud construction. Use of nails for securing boxes is prohibited. Set boxes on opposite sides of common wall with minimum 10" of conduit between them. Provide electrical connections for installed boxes. END OF SECTION 16135 8776/Division 16 16/29 Ricks College Plant Science Basement Remodel outlet boxes being used and fulfilling requirements of individual wiring applications. WEATHERPROOF OUTLET BOXES: Provide corrosion -resistant cast - metal weatherproof outlet wiring boxes, of types, shapes and sizes (including depth) required, with threaded conduit ends, cast -metal face application, with face plate gaskets and corrosion -resistant fasteners. JUNCTION AND PULL BOXES: Provide code -gage sheet steel junction and pull boxes, with screw -on covers; of types, shapes and sizes to suit each respective location and installation; with welded seams and equipped with stainless steel nuts, bolts, screws and washers. CONDUIT BODIES: Provide galvanized cast -metal conduit bodies, of types, shapes and sizes to suit respective locations and installation, construct with threaded -conduit -entrance ends, removable covers, and corrosion -resistant screws. BUSHINGS, KNOCKOUT CLOSURES AND LOCKNUTS: Provide corrosion - resistant punched -steel box nnockout closures, conduit locknuts and malleable iron conduit bushings and offset connectors, or types and sizes to suit respective uses and installation. PART 3 - EXECUTION INSTALLATION OF ELECTRICAL BOXES AND FITTINGS: GENERAL: Install electrical boxes and fittings where indicated, complying with manufacturer's written instructions, applicable requirements of NEC and NECA's "Standard of Installation", and in compliance with recognized industry practices to ensure that products fulfill requirements. Minimum height of wall receptacles shall be 16". Coordinate installation of electrical boxes and fittings with wire/cable and raceway installation work. Provide coverplates for all boxes. See Section 16140, Wiring Devices. Provide weatherproof outlets for interior and exterior locations exposed to weather or moisture. Provide knockout closures or cap unused knockout holes where blanks have been removed. Install boxes and conduit bodies to ensure ready accessibility of electrical wiring. Install recessed boxes with face of box or ring flush with adjacent surface so the device mounting flange 8776/Division 16 16/28 Ricks College Plant Science Basement Remodel SECTION 16135 - ELECTRICAL BOXES AND FITTINGS PART 1 - GENERAL DESCRIPTION OF WORK: Extent of electrical box and electrical fitting work is indicated by drawings and schedules. Types of electrical boxes and fittings in this section include the following: Outlet boxes Junction boxes Full boxes Conduit bodies Bushings Locknuts Knockout closures Miscellaneous boxes and fittings QUALITY ASSURANCE: Comply with NEC as applicable to construction and installation of electrical boxes and fittings. Comply with ANSI C 134.1 (NEMA Standards Pub. No. OS 1) as applicable to sheet -steel outlet boxes, device boxes, covers and box supports. Provide electrical boxes and fittings which have been UL-listed and labeled. SUBMITTALS: None required. PART 2 - PRODUCTS FABRICATED MATERIALS: INTERIOR OUTLET BOXES: Provide one piece, galvanized flat rolled sheet steel interior outlet wiring boxes, of types, shapes and sizes, including box depths, to suit each respective location and installation; construct with stamped knockouts in back and sides, and with threaded screw holes with corrosion -resistant screws for securing box covers and wiring devices; standard box shall be 2- 1/8" x 4" x 4", with masonry/plastic rings. Where structure will not allow a 4 square box use a 3" deep single gauge unit. INTERIOR OUTLET BOX ACCESSORIES: Provide outlet box accessories as required for each installation, including mounting brackets, hangers, extension rings, fixture studs, cable clamps and metal straps for supporting outlet boxes, which are compatible with 8776/Division 16 16/27 Ricks College Plant Science Basement Remodel Distribution and Panelboard Feeders; and other conductors, #2 AWG and larger - (Copper) conductor; see drawings for insulation type. Branch Circuit Conductors and all conductors #3 AWG and smaller copper conductor, with THHN insulation below #10AWG, and THHN above #10AWG, and where ambient temperature conditions exceed 60 degrees C. Size all conductors in accordance with NEC; minimum size to be #12 AWG. Provide stranded conductors for #8 AWG and larger. Provide THHN insulated conductors (in dry areas) from outlets to fixtures, and in fixture channels. Conductor ampacity shall comply when local codes have a derating factor because of ambient temperature. Provide color and coding of conductors as follows: Lighting & Appliance A -phase - - - Black B-phase - - - Red C-phases - - - Blue Neutral - - - White Ground- - - - Green Motor Control Motor Feeders - - -Black Hot or Stop Lead- -Red Start Lead- - - - -Blue Common- - - - - - -White Indicating Light- -Orange Interlock or Shunt -Brown Ground- - - - - - -Green Provide #10 AWG conductor for all three and four wire fluorescent circuit home runs. END OF SECTION 16120 8776/Division 16 16/26 Ricks College Plant Science Basement Remodel SECTION 16120 - CONDUCTORS AND CABLES PART 1 - GENERAL DESCRIPTION OF WORK: Extent of electrical conductor and electrical cable work is indicated by drawings and schedules. Types of conductors_ and cables in this section include the following: Copper Conductors (600V) Applications for conductors and cables required for project include: Feeders Branch Circuits QUALITY ASSURANCE: Comply with NEC as applicable to construction and installation of electrical conductors and cable. Comply with UL standards and provide electrical conductors and cables which have been UL- listed and labeled. Comply with applicable portions of NEMA/Insulated Cable Engineers Association standards pertaining to materials, construction and testing of conductors and cable. Comply with applicable portions of ANSI/ASTM and IEEE standards pertaining to construction of conductors and cable. SUBMITTALS: FIELD TEST DATA: Submit test data in accordance with IEEE Standard 400-1980 showing ambient conditions, voltage levels, level durations, and conduction current for each step. Include effective insulation resistance in submittal. PART 2 - PRODUCTS COPPER CONDUCTORS (600V): Provide factory -fabricated conductors of sizes, ratings, materials, and types indicated for each service. Where not indicated provide proper selection to comply with project's installation requirements and NEC standards. Provide conductors in accordance with the following: 8776/Division 16 16/25 Ricks College Plant Science Basement Remodel Raceway installation in suspended slabs: Install conduit as close to the middle of concrete slab as practicable without disturbing reinforcement. Do not install conduits of diameter greater than 1-1/4" of the slab thickness. Space conduits not less than 3 diameters on center (except at stub up locations). Provide OZ expansion fittings at all expansion joints. All raceways shall be installed with concrete tight fittings. Install RMC in all hazardous locations as defined by NEC. Provide suitable fittings, seal -offs, boxes, etc. to comply with requirements. Conduits encased in concrete shall be shrouded with a 3" of Red concrete. Install a #4 rebar in all four corners of the encasement except for two conduits or less where two #4 bars in opposite corners is acceptable. ROOF FLASHING: Where raceways penetrate roofing or similar area, provide 26 ga. galvanized iron roof jack, sized to fit tightly to raceway for weathertight seal, and with flange extending to a minimum of 9 inches under roofing on all sides. Coordinate all work with roofing contractor. PATCHING AND REPAIR: The Contractor is responsible for all demolition, patching and repair of all finished interior surfaces pertaining to the installation of this particular phase of work. All surfaces shall be finished (painted, etc.) to match the adjacent materials, finishes and color. Hard Surfaces: Whenever demolition or excavation is required for the installation of the electrical system, it should be the responsibility of this Contractor to make repairs and/or replacements of hard finish surfaces such as concrete, asphalt, etc. Lawn replacement is also included as a part of this section. The method of patching and repair should follow good construction practices and all finished surfaces shall match materials and finish wherein the demolition occurred. END OF SECTION 16110 8776/Division 16 16/24 Ricks College Plant Science Basement Remodel Where raceways penetrate building or vault walls and floors below grade, install rigid metal conduit (RMC) for a minimum distance of 10 ft. on the exterior side of the floor or wall. Provide OZ, Type FSK or WSK sealing bushings (with external membrane clamps as applicable) for all conduit penetrations entering building or vaults below grade. Install liquid -tight flexible conduit for connection of motors, transformers, and other electrical equipment where subject to movement and vibration. Install five spare 3/4" conduit (capped) from each branch panelboard into the ceiling and floor space. Where the floor is not accessible run six conduits into the ceiling space. Run conduits the required distance necessary to reach accessible ceiling space. Provide OZ expansion fittings on all conduits crossing building expansion joints, both in slab and suspended. Complete ins�allation of electrical raceways before starting installation of cables/conductors within raceways. EXCAVATION AND BACKFILL: Raceway installation below slab -on -grade, or below grade: The Electrical Contractor is responsible for all excavation and backfill. Backfill shall be compacted in 6" layers to a 90% Standard Proctor Test. For slab -on -grade construction, install runs or rigid plastic conduit (PVC) below slab. Install RMC (with protective coating) for raceways passing vertically through slabs on grade. Slope raceways as required to drain away from electrical enclosures and to avoid collection of moisture in raceway low points. Apply protective coating to metallic raceways in direct contact with earth or fill of any type; consisting of spirally wrapped PVC tape (1/2" minimum overlap os scotch wrap tape or equal); or factory applied vinyl cladding (minimum thickness .020 inches). Completely wrap and tape all field joints. Mark all buried conduits which do not require concrete encasement by placing yellow plastic marker tape (minimum 6" wide) along entire length of run 12" below final grade. Where multiple small lines are buried in a common trench and do not exceed an overall width of 16", install a single line marker. 8776/Division 16 16/23 Ricks College Plant Science Basement Remodel FIRE PENETRATION SEALS All penetrations through fire rated floors and walls shall be sealed to prevent the spread of smoke, fire, toxic gas or water through the penetration either before, during or after the fire. The fire rating of the penetration seal shall be at least that of the floor or wall into which it is installed so that the original fire rating of the floor or wall is maintained as required by Article 300--21 of the National Electrical Code. The sealant shall remain soft and pliable to allow for the removal and/or addition of cables without the necessity of drilling holes. It shall adhere to itself to allow any and all repairs to be made with the same material. It shall permit the vibration, expansion and/or contraction of raceways and/or cables going through the penetration without the seal cracking or crumbling. When damming materials are to be left in place after the seal is complete, all such materials shall be non-flammable. When sealant is injected into a penetration, the foam shall expand to surround all items within the penetration and maintain pressure against the walls of the penetration. The foam shall cure within five minutes and be fire resistant at that time. No heat shall be required to further expand the foam to block the passage of fire and smoke or water. All wall or floor penetration openings shall be as small as possible. The foam sealant shall meet all of the fire test and hose stream test requirements of ASTM E119-73 and shall be UL Classified as a Wall Opening Protective Device. The sealant shall be CHASE -FOAM CTC PR-855 Fire Resistant Foam Sealant from Chase Technology Corporation, Huntington Station, New York 11746, or equals of 3- M. Comply with NEC for requirements for installation of pull boxes in long runs. Cap open ends of conduits and protect other raceways as required against accumulation of dirt and debris. Pull a mandril and swab through all conduit before installing conductors. Install a 200 lb. nylon pull cord in each empty conduit run. Replace all crushed, wrinkled or deformed raceway before installing conductors. Provide rigid metal conduit (RMC) for all bends in buried conduit greater than 30 degrees. Provide protective coating for RMC bend as specified herein. 8776/Division 16 16/22 Ricks College Plant Science Basement Remodel PART 3 - EXECUTION INSTALLATION OF ELECTRICAL RACEWAYS: Install electrical raceways where indicated; in accordance with manufacturer's written instructions, applicable requirements of NEC and NECA "Standard of Installation", and in accordance with the following. FEEDERS UNDER 600 VOLTS: Install feeders to panels and motor control centers and individual equipment feeders rated 100 amps and greater, in rigid metal conduit (RMC), or intermediate metal conduit (IMC); except where buried below grade, install in non- metallic conduit or duct. Feeders 1-1/2" round and larger shall be encased in concrete as a part of the floor. Not up in the floor, but just below the floor with the top of the conduit touching the bottom of the slab and the bottom of the conduit being covered with at least 1" of concrete. BRANCH CIRCUITS, SIGNAL AND CONTROL CIRCUITS, AND INDIVIDUAL EQUIPMENT CIRCUITS RATED LESS THAN 100 AMPS: Install in electric metallic tubing (EMT); except in poured walls, below concrete slab -on -grade, or in earth fill, install in non-metallic plastic duct. Encase non-metallic plastic duct 1-1/4" and larger in concrete. Coordinate with other work, including metal and concrete deck work, as necessary to interface installation of electrical raceways and components. Install raceway in accordance with the following: Provide a minimum of 12" clearance from flues, steam and hot water piping, etc. Avoid installing raceways in immediate vicinity of boilers and similar heat emitting equipment. Conceal raceways in finished walls, ceilings and floors (other than slab -on -grade). Where conduit is exposed in mechanical spaces, etc., install parallel with or at right angles to building or room structural lines. Where cutting raceway is necessary, remove all inside and outside burrs; make cuts smooth and square with raceway. Paint all field threads (or portions of raceway where corrosion protection has been damaged) with primer and enamel finish coat to match adjacent raceway surface. 8776/Division 16 16/21 Ricks College Plant Science Basement Remodel where required by application. Provide double locknuts and metal bushings at conduit terminations, use OZ Type B bushing on conduits 1-1/4" and larger. ELECTRICAL METALLIC TUBING (EMT): FS WW-C-563 and ANSI C80.3. EMT FITTINGS: Provide insulated throat non -indenter type malleable steel fittings; concrete tight where required by application. Install OZ Type B bushings on conduits 1-1/4" and larger. FLEXIBLE METAL CONDUIT: FS WW-C-566, of the following type: Zinc -coated steel. FLEXIBLE METAL CONDUIT FITTINGS: FS W-F-406, Type 1 Class 1, and Style A. LIQUID -TIGHT FLEXIBLE METAL CONDUIT: Provide liquid -tight, flexible metal conduit; constructed of single strip, flexible, continuous interlocked, and double -wrapped steel; galvanized inside and outside; coated with liquid -tight jacket of flexible polyvinyl chloride (PVC). LIQUID -TIGHT FLEXIBLE METAL CONDUIT FITTINGS: FS W-F-406, Type 1, Class 3, Style G. EXPANSION FITTING: OZ Type AX, or equivalent of suit application. NON-METALLIC CONDUIT AND DUCTS: GENERAL: Provide non-metallic conduit, ducts, and fittings of types, sizes and weights (wall thicknesses) as indicated; with minimum trade size of 3/4". UNDERGROUND PVC PLASTIC UTILITIES DUCT: ANSI/NEMA TC 6, Type 1 for encased burial in concrete, Type II for direct burial. PVC AND ABS PLASTIC UTILITIES DUCT FITTINGS: ANSI/NEMA TC 9, match to duct type and material. CONDUIT, TUBING, AND DUCT ACCESSORIES: Provide conduit, tubing and duct accessories of types, sizes, and materials, complying with manufacturer's published product information, which mate and match conduit and tubing. SEALING BUSHINGS: Provide OZ Type FSK, of FSKA. 8776/Division 16 16/20 Ricks College Plant Science Basement Remodel SECTION 16110 - CONDUIT RACEWAYS PART 1 - GENERAL DESCRIPTION OF WORK: Extent of raceways in indicated by drawings and schedules. Types of raceways in this section include the following: Electrical metallic tubing. Flexible metal conduit. Intermediate metal conduit. Liquid -Tight flexible metal conduit. Rigid metal conduit. Rigid non-metallic conduit. QUALITY ASSURANCE: MANUFACTURERS: Firms regularly engage in manufacture of raceway systems of types and sizes required, whose products have been in satisfactory use in similar service for not less that three (3) years. STANDARDS: Comply with applicable portions of NEMA standards pertaining to raceways. Comply with applicable portions of UL safety standards pertaining to electrical raceway systems; and provide products and components which have been UL-listed and labeled. Comply with NEC requirements as applicable to construction and installation of raceway systems. SUBMITTALS: Not required. PART 2 - PRODUCTS METAL CONDUIT AND TUBING: GENERAL: Provide metal conduit, tubing and fittings or types, grades, sizes and weights (wall thicknesses) as indicated; with minimum trade size of 3/4". RIGID METAL CONDUIT (RMC): FS WW-C-0581 and ANSI C80.1. INTERMEDIATE STEEL CONDUIT (IMC): FS WW-C-581. PVC EXTERNALLY COATED RIGID STEEL CONDUIT: ANSI C80.1 and NEMA Std. Pub. No. RN 1. RIGID AND INTERMEDIATE STEEL CONDUIT FITTING: Provide fully threaded malleable steel couplings; raintight and concrete tight 8776/Division 16 16/19 Ricks College Plant Science Basement Remodel The new electrical equipment and apparatus shall be coordinated and connected into the existing system as required. Auxiliary systems shall comply unless otherwise specified. The new fixtures indicated for existing outlets shall be installed in accordance with the fixture specifications. New conductors shall be installed from the panel to each existing outlet. Conduit and wire installed in existing structures shall be concealed. If not possible, install in wiremold. Before installation, confirm with Architect. All electrical equipment and apparatus in the building not remodeled shall be connected as per specifications and left in working conditions. Vacated or unused circuits shall have wire pulled out of conduit back to branch panel or the first active outlet. All circuits, conduit and wire that are not used in the remodeling shall be removed back to the first accessible junction box where it shall be tied off, taped and labeled spare and what it connects to. The existing light fixtures, which are not used in the remodeled area, shall be carefully removed (DO NOT DAMAGE), placed in cartons, and turned over to the Owner. Those fixtures indicated for re -use shall be thoroughly cleaned, repaired as required, relamped and installed as indicated. Obtain permission from the building maintenance director before penetrating any ceiling, floor, and wall surfaces. Any and all equipment having electrical connections that require disconnecting and reconnection, at the same or another location throughout the course of construction, shall be included as part of this contract. END OF SECTION 16070 8776/Division 16 16/18 Ricks College Plant Science Basement Remodel to equipment, control cabinet, terminal junction box or wiring terminals. Totally enclose all wiring in raceway. 2. Movable and/or portable equipment - wiring device, cord cap, and multi -conductor cord suitable for the equipment and in accordance with NEC requirements (Article 400). 3. Other methods as required by National Electrical Code and/or as required by special equipment of field conditions. PART 3 - EXECUTION INSTALLATION OF ELECTRICAL CONNECTIONS: Make electrical connections in accordance with connector manufacturer's written instructions and with recognized industry practices, and complying with requirements of NEC and NECA's "Standard of Installation" to ensure that product fulfill requirements. Connect electrical power supply conductors to equipment conductors in accordance with equipment manufacturer's written instructions and wiring diagrams. Coordinate installation of electrical connections for equipment with equipment installation work. Verify all electrical loads (voltage, phase, full load amperes, number and point of connections, minimum circuit ampacity, etc.) for equipment furnished under other Divisions of this specification, by reviewing respective shop drawings furnished under each division. Meet with each subcontractor furnishing equipment requiring electrical service and review equipment electrical characteristics. Report any variances from electrical characteristics noted on the electrical drawings in writing to Architect before proceeding with rough -in work. Obtain and review the equipment shop drawings to determine particular final connection requirements before rough -in begins for each equipment item. Refer to basic materials and methods Section 16120, Conductors, for identification of electrical power supply conductor terminations. EXISTING EQUIPMENT: General: The following are part of this project, and all costs pertaining thereto shall be included in the base bid. Disconnect all equipment that obstructs and/or is to be relocated. Reconnect when reset. 8776/Division 16 16/17 Ricks College Plant Science Basement Remodel SECTION 16070 _ ELECTRICAL CONNECTIONS FOR EQUIPMENT PART 1 - GENERAL DESCRIPTION OF WORK: EQUIPMENT CONNECTIONS: The Contractor shall install an electric service to the subject project as shown on the plans and described herein. Extent of electrical connection for equipment includes final electrical connection of all equipment having electrical requirements. Make final connections for all owner furnished equipment. See other applicable portions of specification for building temperature control wiring requirements. Refer to Division-15 sections for motor starters and controls furnished integrally with equipment; not work of this section. Refer to Division-15 section for control system wiring; not work of this section. Refer to sections of other Divisions for specific individual equipment power requirements. QUALITY ASSURANCE: NEC COMPLIANCE: Comply with applicable portions of NEC as to type products used and installation of electrical power connections. UL LABELS: Provide electrical connection products and materials which have been UL-listed and labeled. PART 2 - PRODUCTS GENERAL: For each electrical connection indicated, provide complete assembly of materials, including but not necessarily limited to; raceways, conductors, cords, cord caps, wiring devices, pressure connectors, terminals (lugs), electrical insulating tape, heat -shrinkable insulating tubing, cable ties, solderless wire nuts, and other items and accessories as needed to complete splices, terminations, and connections as required. See Section 16110, Conduit Raceways; Section 16140, Wiring Devices; and Section 16120 Wire Cables for additional requirements. Provide final connections for equipment consistent with the following: 1. Permanently installed fixed equipment - flexible seal -tight conduit from branch circuit terminal equipment, or raceway; 8776/Division 16 16/16 Ricks College Plant Science Basement Remodel all equipment Factory Representative and Subcontractors for system start-up. Each Representative and Subcontractor shall assist in start-up and check out their respective system and remain at the site until the total system operation is accepted by the Owner's Representative. The Factory Representative and/or System Subcontractor shall give personal instruction on operation and maintenance of their equipment to the Owner's maintenance and/or operation personnel. To certify acceptance of operation and instruction by the Owner's Representative, the contractor shall prepare a written statement as follows: This is to certify that the Factory Representative and/or System Subcontractor for each of the systems installed below have performed start-up and final check out of their respective systems is satisfactory. The Owner's Representative has received complete and thorough instruction in the operation anu maintenance of each system. The Owner's Representative has received and accepted all spare parts required by contact. System (List Systems Included) Owner's Representative Factory Representative (List name and address of Factory Representative) Contractor Send copy of acceptance to Architect/Engineer. FINAL REVIEW: At the time of final review, the project foreman shall accompany the reviewing party, and remove coverplates, panel covers and other access panels as requested, to allow review of the entire electrical system. END OF SECTION 16001. 8776/Division 16 16/15 Ricks College Plant Science Basement Remodel Provide block -outs, sleeves, demolition work, etc., required for installation of work specified in this Division. COMPLETION OF WORK AND TESTING: Before energizing any circuits, make meager ground tests on conductors, bus duct and fused disconnects with the distribution breakers open and all circuits feeding from the main panel. These readings shall be recorded with their circuits and submitted in triplicate to the Owner's Representative before the system is energized. Submit with a letter of guarantee a triplicate record of a voltage reading and ammeter reading on all phases of feeders, motors, outside lighting, and the main service to the facility. (These readings shall be taken with all equipment operating.) A second reading shall be taken and submitted in writing when the building is occupied and in full service (kitchens, shops, systems, etc. in operation). If there are any abnormal conditions, they shall be brought to the attericion of the Engineer in writing as a part of this submittal. Also submit with the load readings for the motors, a list of motors with the size of overload heaters used for each motor. This includes thermo switches. Before final inspection, but after the electrical installation is complete, the Electrical Contractor shall remove neutral grounding connection from main distribution panel and show to Inspector and Owner's Representative, by an ohmmeter, that the electrical system neutral is grounded through main panel location only. Neutral shall be reconnected after the test is complete. Emergency Power System: In the presence of the Owner's Representative, test the emergency power system, in its entirety, by transferring from normal to emergency power no less than six times. This means to prove proper operation of all equipment, devices, light fixtures, etc. that are powered by this system. If an emergency generator or power pack is used, the factory representative should be present during the test. Write a letter to the Owner's Representative confirming the conditions of this test. Auxiliary systems - Each system shall be made operational by the factory representative. He shall confirm the operator of each component (speaker, stand by power, etc.) and report in writing (triplicate) his confirmation of the systems status of operator. PROJECT FINALIZATION AND START-UP: Upon completion of equipment and system installation, assemble 8776/Division 16 16/14 Ricks College Plant Science Basement Remodel spare set of each additional group of five (this includes fuses for bolted pressure and HV units). Diffusers: Provide a spare set of diffusers for each fixture type and one for each additional 10 fixtures of each type; not to exceed 10 spares for any singly fixture type. Lamps: Provide replacement lamps amounting to 15% (not less than one lamp) of each type and size used. The quantity of any one single lamp type should not exceed 48. Thermal Overloads: Provide one spare set of thermal overload heaters of each type used in the magnetic starters. Auxiliary Systems: One spare heat and smoke detector shall be provided for the system. PART 3 - EXECUTION INSTALLATION: Lay out electrical work in advance of construction to eliminate unnecessary cutting, drilling, channeling, etc. Where such cutting, drilling, t-;r channeling becomes necessary for proper installation; perform with care. Use skilled mechanics of the trades involved. Repair damage to building and equipment at no additional cost to the contract. Cutting work of other Contractors shall be done only with the consent of that Contractor. Cutting structural members shall not be permitted. Since the drawings of floor, wall, and ceiling installation are made at small scale, outlets, devices, equipment, etc., are indicated only in their approximate location unless dimensioned. Locate outlets and apparatus symmetrically on floors, walls and ceilings where not dimensioned, and coordinate such locations with work of other trades to prevent interferences. Verify all dimensions on the job. Do not scale the electrical drawings, but refer to the architectural and mechanical shop drawings and project drawings for dimensions as applicable. Perform for other trades, the electrical wiring and connection for all devices, equipment or apparatus. Consult, Architectural, Mechanical, and other applicable drawings, and all applicable shop drawings to avoid switches, outlets, and other equipment from being hidden behind doors, cabinets, counters, heating equipment, etc. Relocate buried electrical devices and/or connection as directed at no additional cost. Where conduit, outlets or apparatus are to be encased in concrete, it must be located and secured by a journeyman or foreman present at the point of installation. Check locations of the electrical items before and after concrete and/or masonry installation and relocate displaced items. 8776/Division 16 16/13 Ricks College Plant Science Basement Remodel SUBSTITUTIONS AND BIDDING: The equipment specified carries brand names and catalog numbers and shall be interpreted as establishing a standard of quality. Substitutions will be considered if a duplicate written application (two copies) is at the office of the engineer eight (8) working days prior to the day of bidding. The application shall include the following: 1) A statement declaring the equipment proposed is equal to that specified by having the same physical characteristics and dimensions and meet the drawings layout and structural conditions as well as load requirements; 2) The specified and submittal catalog numbers of the equipment under consideration; 3) A pictorial and specification brochure. Any conflict arising from the use of substituted equipment shall be the responsibility of the supplier, who shall bear all costs required to make the equipment comply with the intent of the plans and specifications. At the option of the Architect, samples may be required for non- standard or substituted items before installation during construction. No materials or apparatus shall be substituted after the bid opening except where the equipment manufacturer has been discontinued or delivery becomes a problem, then written approval if the Architect is required. Bidding -- Only equipment specified in the contract documents and or approved by an addendum will be used in the base bid. INCENTIVE BIDS: Suppliers of materials, equipment, and systems are encouraged to submit incentive bids by grouping several products under one bid. However, all incentive bids must list the individual item and cost thereof in his quotation form as unitized. This will afford the Contractor to make specific addition to or deductions from the base bid. The base bid must be based upon specified items, or items approved by addendum. SPARE PARTS: Provide spare parts (fuses, overload heaters, diffusers, lamps, etc.) as specified. Transmit all spare parts to Owner's Representative in writing prior to substantial completion. Submit copy of transmittal letter to Engineer. Fuses: Provide one spare set of fuses for each size used and one 8776/Division 16 16/12 Ricks College Plant Science Basement Remodel PART 2 - PRODUCTS GENERAL: Products are specified by Manufacturer name, description, and/or catalog number. Discrepancies between equipment specified and the intended function of equipment shall be brought to the attention of the Architect/Engineer in writing prior to bidding. Failure to report any conflict, including catalog numbers, discontinued products, etc., does not relieve the Contractor from meeting the intent of the contract documents, nor shall it change the contract cost. If the Contractor is unable to interpret any part of the plans and/or specifications, or should he find discrepancies therein, he shall bring this to the attention of the Architect/Engineer, who will issue interpretation and/or additional instructions to Bidders before the project is bid. MANUFACTURERS: Provide products of manufacturers specified (or equivalent products of other manufacturers). Manufacturer's catalog numbers and descriptions establish the quality of product required. Substitutions will be considered if a duplicate written application (2-copies) is at the office of the Architect/Engineer eight (8) working days prior to the day of bidding. The application shall include the following: 1) A statement certifying that the equipment proposed is equal to that specified; that it has the same electrical and physical characteristics, compatible dimensions, and meets the functional intent of the contract documents; 2) The specified and submittal catalog numbers of the equipment under consideration; 3) A pictorial and specification brochure. Any conflict arising from the use of substituted equipment shall be the responsibility of the contractor, who shall bear all costs required to make the equipment comply with the intent of the contract documents. Samples may be required for non-standard or substituted items before installation during construction. Provide all samples as required. No materials or apparatus may be substituted after the bid opening except where the equipment specified has been discontinued. This substitution must be made by a change order. Provide only equipment specified in the contract documents or approved by addendum. 8776/Division 16 16/11 Ricks College Plant Science Basement Remodel persons in the vicinity. Protect completed work, work underway, and apparatus against loss or damage. CONCRETE BASES: Unless otherwise noted, provide a 4" high concrete base for all main panels, motor control centers, transformers, motor generators, etc. Extend base 4" beyond equipment or mounting rails on all sides or as shown on the drawings. Coordinate the pad dimension with the equipment to be located thereon. Concrete bases shall be provided under Division-16. Coordinate size and location of all bases and furnish all required anchor bolts, sleeves and templates as required to obtain a proper installation. ELECTRICAL -MECHANICAL COORDINATION: General - All disconnect means, motor controllers, and all electrical controls, protective, and signal devices for mechanical equipment as noted in Division 15 of these specifications shall be furnished, installed, wired, and connected under Division 16 with the following exceptions. Pressure switches, thermostats, solenoid valves, damper motors, and similar equipment will be supplied and installed under the Mechanical Division for connection under this Division. Connection diagrams will be supplied as hereafter explained. When the equipment supplied under Division 15 results in a change to the contract documents and/or installation costs, the supplier of that equipment shall reimburse the Division 16 contractor for that expense. If the substitution of equipment in Division 15 result in a change to the contract documents and/or changes to the installation requirements (not covered by the contract change orders) the complete responsibility for costs shall be assigned to the section of these specifications under which the equipment is furnished. EQUIPMENT CONNECTION DIAGRAM: Submittal data for each individual electrically operated or electrically controlled item of equipment or device furnished under Division 15 and/or 16 of the contract documents shall include complete electrical wiring diagrams and elementary control diagrams (ladder form) showing all internal and external wiring connections and services. The submittal data shall Itemize all electrical characteristics that are of a special nature or critical to the electrical installation or control system. Such equipment and devices will not be considered for approval until these requirements are met. 8776/Division 16 16/10 Ricks College Plant Science Basement Remodel Certify the "Record Drawings" for correctness by placing and signing the following certifications on the first sheet of the sepias: "CERTIFIED CORRECT (3/8" high letters) By Date (Name of General Contractor) By Date (Name of Electrical Contractor) GUARANTEE: Ensure that electrical system installed under this contract is in proper working order and in compliance with drawings, specifications and/or authorized changes. Without additional charge, replace any work or materials which develop defects, except from ordinary wear and tear, within one year from the date of substantial completion. Exception: Incandescent and fluorescent lamps shall be guaranteed for a period of two months from the date of substantial completion. CLEAN-UP: Clean up all equipment, conduit, fittings, packing cartons and other debris that is a direct result of the installation of THW work of this Division. Clean fixtures, interiors and exteriors of all equipment, and raceways. Replace all filters in electrical equipment upon request for Substantial Completion. POWER OUTAGE: All power outages required for execution of this work shall occur during non-standard working hours and at the convenience of the Owner. Include all costs or overtime work in bid. Submit written request at least 7 days in advance of scheduled outage and proceed with outage only after receiving authorization from the Owner's Representative. Keep all outages to an absolute minimum. STORAGE AND PROTECTION OF MATERIALS: Provide storage space for storage of materials and apparatus and assume complete responsibility for all losses due to any cause whatsoever. In no case shall storage interfere with traffic conditions in any public thoroughfare or constitute a hazard to 8776/Division 16 16/9 Ricks College Plant Science Basement Remodel Assemble all data in a completely indexed volume or volumes and identify the size, model, and features indicated for each item. The binder (sized to the material) shall be a 2" slide lock unit (Wilson -Jones B3-367-44). The cover shall be engraved with the job title in 1/2" high letters and the name and address of the Contractor in 1/4" high letters. Provide the same information in 1/8" letters on the spine. Include complete cleaning and servicing data compiled in clearly and easily understandable form. Show serial numbers of each piece of equipment, complete list of replacement parts, motor ratings, etc. Each unit shall have its own individual sheet. (Example: If two items of equipment A and D appear on the same sheet, an individual sheet shall be provided for each unit specified.) Include the following information where applicable: 1. Identifying name and mark number. 2. Certified outline Drawings and Shop Drawings. 3. Parts lists. 4. Performance curves and data. 5. Wiring diagrams. 6. Manufacturer's recommended operating and maintenance instructions. 7. Vendor's name and address for each item. RECORD DRAWINGS: Maintain, on a daily basis, a complete set of "Record Drawings", reflecting an accurate dimensional record of all buried or concealed work. Mark "Record Drawings" to show the precise location of concealed work and equipment, including concealed or embedded conduit and junction boxes and all changes and deviations in the work from that shown on the Contract Documents. This requirement shall not be construed as authorization for the Contractor to make changes in the layout or work without definite authorization for such changes. The "Record Drawings" for daily recording shall consist of a set of blue line prints of the Contract Drawings. Record dimensions clearly and accurately, delineating the work as installed; identify locations by at least two dimensions to permanent reference points. Upon completion of the work, purchase a complete set of reproducible sepia drawings with the Architect/Engineer's seal and firm name removed or blacked out. Transfer all "Record" information from the blue line prints to the sepias. 8776/Division 16 16/8 Ricks College Plant Science Basement Remodel Certifications shall be written or in the form of rubber stamp impressions as follows: I hereby certify that this Shop Drawing and/or Brochure has been checked prior to submittal and that it complies in all respects with the requirements of the Contract Drawings and Specifications for this Project. (Name of Electrical Subcontractor) Signed Position Date Observe the following rules when submitting Shop Drawings and Brochures. 1. Each Shop Drawing shall indicate in the lower right hand corner, and each Brochure shall indicate on the front cover the following: Title of the sheet or brochure, name and location of the building; names of the Architect and Electrical Engineer, Contractor, Subcontractors, Manufacturer, Supplier/Vendor, etc., date of submittal, and the date of correction and revision. Unless the above information is included, the submittal will be returned for resubmittal. 2. Shop Drawings shall be done in an easily legible scale and shall contain sufficient plans, elevations, sections, and isometrics to clearly describe the equipment or apparatus, and its location. Drawings shall be prepared by an Engineer/Draftsman skilled in this type of work. Shop Drawings shall be drawn to at least 1/4"-1/0" scale. 3. Brochures to be submitted shall be published by the Manufacturers and shall contain complete and detailed engineering and dimensional information. Brochures submitted shall contain only information relevant to the particular equipment or materials to be furnished. The Contractor shall not submit catalogs which describe several different items in addition to those items to be used, unless all irrelevant information is marked out, or unless relevant information is clearly marked. Brochures from each manufacturer shall be identified and submitted separately. OPERATION AND MAINTENANCE MANUALS: Provide operating instructions and maintenance data books for all equipment and materials furnished under this Division. Submit four copies of operating and maintenance data books for review at least four weeks before final review of the project. 8776/Division 16 16/7 Ricks College Plant Science Basement Remodel circuit to which the device is connected. Example: Circuit "A- 1". The power riser diagram sealed in plexiglass and trimmed with a metal frame shall be provided and installed at the Main Panel in the switch gear room (locate as directed). Engraving device plates - see WIRING DEVICES. All switch banks shall have each switch identified as to its function with micarta engraved adhesive backed plate. All high voltage cable and equipment shall be labeled with a luminescent permanent label with 2" high letters, stating the Primary Voltage, and DANGER, HIGH VOLTAGE sign on the transformer vault door. SUBMITTALS: SHOP DRAWINGS AND PRODUCT DATA: After the contract is awarded, but prior to manufacture or installation of any equipment, prepare complete Shop Drawings and Brochures for materials and equipment as required by each section of this specification. Submit complete, bound su mbittal in a looseleaf binder large enough for all items (8 copies) to Architect. Prior to submission of the Shop Drawings and Project Data, review and certify that they are in compliance with the Contract Documents. Verify all dimensional information to insure proper clearance for installation of equipment. Check all materials and equipment after arrival on the job site and verify compliance with the Contract Documents. A minimum period of two weeks, exclusive of transmittal time, will be required each time a Shop Drawing and/or Brochure is submitted or resubmitted for review. This period shall be considered by the Contractor when scheduling submittal data. Review of Shop Drawings and Brochures shall not relieve the Contractor of responsibility for dimensions and/or errors that may be contained therein, or deviations from the Contract Document's requirements. It shall be clearly understood that the noting of some errors but overlooking others does not grant the Contractor permission to proceed in error. Regardless of any information contained in the Shop Drawings and Brochures, the requirements of the Contract Documents shall govern and are not waived, or superceded in any way by the review of the Shop Drawings an Brochures. 8776/Division 16 16/6 Ricks College Plant Science Basement Remodel and the Controls Contractor. The contract drawings will be revised by one of the two following procedures: 1. If the revisions to the controls diagrams shown on the contract drawings are minor in the opinion of the Architect, the contract drawings will be revised and re -issued by and at the expense of the Architect. 2. If the revisions to the control diagrams shown on the contract drawings are ruled major in the opinion of the Architect/Engineer, the Prime Contractor shall prepare and submit a complete set of reproducible drawings of the control diagrams proposed for installation. These drawings shall be prepared on the same size sheets as the contract drawings and shall follow the same general format and quality of drafting as the contract drawings. After these reproducible drawings have been reviewed and approved by the Architect/Engineers and certified, the revised prints will be re -issued to the Contractor at the expense of the Design Engineers. Changes During Construction: The complete responsibility and costs for changes to the approved control diagrams during construction and the resultant changes to the installation requirements not covered by contract change orders, shall be assigned to the respective section of these specifications under which the equipment is furnished. BASIC MATERIALS AND METHODS: Labeling: Engraved black formica with white core labels, 1/16" thick shall be bolted on the interior and the exterior of branch panels (panel name and voltage) and the exterior of disconnect switches, motor controls, major J-boxes (power and auxiliary), push buttons, thermal switches, time switches and similar equipment. The labels shall have 1/4" high engraved letters, such as 1-1/2 HP FAN, PANEL - A. All main panel circuits shall be identified with Micarta labels. (RED MICARTA LABELS shall be used on emergency powered equipment The phase of each feeder conductor shall be color coded at each end in panels and junction boxes. A plastic label, as noted above with the name and address of the Engineer - the profession indicated - shall be bolted to the front of the Main Power Panel. The engraved letters in the name and address shall be 1/2" and 1/4" high, respectively. Write with a felt tip pen that contains permanent ink, on the inside of each device box and on the back of every plate, the 8776/Division 16 16/5 Ricks College Plant Science Basement Remodel COORDINATION WITH CEILING AND MECHANICAL SUBCONTRACTORS: Meet at least twice with the Ceiling Contractor. The first meeting shall accomplish coordination of all ceiling types with the specified light fixtures. The second meeting shall be held at the project site prior to installing the ceiling to coordinate the fixture layout in each area, and to determine if the depth will allow the installation of the fixture. If a conflict occurs with the layout or depth, the Engineer shall be contacted immediately so the conditions can be adjusted. A letter confirming the second meeting shall be sent to the Engineer with a copy to the Architect. Meet at least once with the Mechanical Contractor prior to fabrication and installation of the ductwork to coordinate the depth and location of light fixtures and ductwork in all areas. All conflicts must be resolved before light fixtures are released for shipment. A letter confirming this meeting shall be sent to the Engineer with a copy to the Architect. WIRING DIAGRAMS: As soon as possible after the contract to proceed is signed, one print of the control diagrams shown on the contract drawings shall be developed (utilize the information on the contract documents) and Control Subcontractors, showing all necessary connections required for the equipment and devices proposed for installation. These prints shall be reviewed and approved by the Mechanical, Electrical, and Controls Subcontractor, and then submitted to the Architect/Engineer for approval. The prints shall indicate all components that are to be wired into the control power circuit by the Electrical Subcontractor, with all terminals for external connections of the components identified and labeled to correspond to the manufacturer's designations. Internal or factory installed wiring or package -type components need not be shown. The shop drawings for the Control System to by installed by the Controls Subcontractor shall be prepared as a separate and complete submittal and need not be entirely repeated on the indicated prints except for the related electric connections. Color coding designations shall be indicated the control power circuit wiring to be installed in the field by the Electrical Subcontractor. Revised Drawings: After the Architect has approved the submitted copy of the control diagrams, the contract drawings will be revised and the Contractor will be issued ten revised prints. The revised control diagrams shall be certified in writing as being acceptable to the Mechanical Design Engineer, Electrical Design Engineer, Mechanical Contractor, Electrical Contractor, 8776/Division 16 16/4 Ricks College Plant Science Basement Remodel Architect shall be afforded every facility deemed necessary to inspect and examine the materials and apparatus being installed to prove their quality, skill and competency of workmanship. DEMOLITION: This Contractor shall be responsible for block -outs or demolition work pertaining to the installation of the electrical system. Seal around all electrical equipment penetrating outside walls, roofs, unheated spaced, air plenums, cold boxes, etc., with Dow Corning Silicone RTV foam. All salvageable electrical equipment and materials that cannot be integrated into the new electrical network becomes the property of the Owner. PROGRESS AND COORDINATION OF WORK: The electrical work shall be laid out in advance of construction to eliminate unnecessary cutting, drilling, channeling, etc. Where such cutting and drilling, or channeling becomes necessary for proper installation perform with care, use skilled mechanics of the trades involved, repair damage to building and equipment at no additional cost to the Owner. Cutting work of other trades shall be done only with the consent to the General Contractor. Cutting of structural members shall be done only with the approval of the Architect. Cooperate with other trades to coordinate locations of electrical outlets and apparatus. Perform for other trades, the electrical wiring and connections for all devices or apparatus where not specified herein or indicated on the drawings. Consult the Architectural and Mechanical drawings to avoid the location of switches, outlets and other equipment from being hidden behind doors, cabinets, counters, heating equipment, etc. Buried electrical devices and/or connections shall be relocated as directed, at no additional cost to the Owner. Where conduit, outlets or apparatus is to be cast in concrete or encased, it must be located and secured by a journeyman or foreman present at the point of installation. He shall check the locations of the electrical items before and after the concrete and masonry installation and shall relocate displaced items. No changes shall be made in the design or location of apparatus unless specifically approved in writing. 8776/Division 16 16/3 Ricks College Plant Science Basement Remodel to determine existing conditions affecting electrical and other work. All costs arising from site conditions and/or preparation shall be included in the base bid. No additional charges will be allowed due to inadequate site inspection. INTERPRETATION OF DRAWINGS AND SPECIFICATIONS: Before bidding, Contractor shall familiarize himself with the drawings, specifications and project site. Submit requests for clarification to Architect/Engineer in writing prior to issuance of final addendum. After signing the contract, the Contractor shall meet the intent, purpose, and function of the contract documents. Any costs of materials, labor, and equipment arising therefrom, to make each system complete and operable, is the responsibility of the Contractor. QUALITY ASSURANCE: Comply with the requirements of State and Local Ordinances. If a conflict occurs between these requirements and the contract documents, the most stringent requirements shall govern. The contractor accepts this responsibility upon submitting his bid, and no extra charge will be allowed after the contract is awarded. This shall not be construed as relieving the Contractor from complying with any requirements of the contract documents which may be in excess of the aforementioned requirements, and not contrary to same. Obtain all permits, inspections, etc. required by authority having jurisdiction. Include all fees in bid. Furnish a certificate of approval to the Owner's Representative from the Inspection Authority at completion of the work. Employ only qualified craftsmen with at least three years of experience (in power equipment, conduit work, high voltage equipment, etc.). Workmanship shall he neat, have a good mechanical appearance and conform to best electrical construction practices. Provide a competent superintendent to direct the work at all times. Any person found incompetent shall be discharged from the project and replaced by satisfactory personnel. Contractor shall have a current state contracting license applicable to type of work to be performed under this contract. MATERIALS AND WORKMANSHIP: All materials and equipment furnished and installed shall be first quality, new and meet the standards of NEMA, IPCEA, LS, UL, NFPA, UBC, OSHA, NEC, and shall bear their label wherever standards have been established and label service is available. Where materials and equipment are specified by manufacturer's name, the type and quality required is thereby denoted. The 8776/Division 16 16/2 Ricks College Plant Science Basement Remodel SECTION 16001 - ELECTRICAL GENERAL PROVISIONS PART 1 - GENERAL RELATED DOCUMENTS: Drawings and general provisions of Contract, including General and Supplementary Conditions and Division - 1 Specification sections, apply to work of this section. This is Division 16 and each division recorded hereafter makes reference to the electrical systems, equipment, materials, connections, etc., and apply to all the work making reference and/or titled electrical. Architectural, Structural, Mechanical and other applicable documents are considered a part of the electrical documents insofar as they apply as if referred to in full. DESCRIPTION OF WORK: Extent of electrical work is indicated on drawings and/or specified in Division 16 sections of the specification. Provide all labor, materials, equipment, supervision and service necessary for a complete electrical system. Work includes, but is not necessarily limited to, the following items: ITEM SECTION Electrical Connections for Equipment 16070 Conduit Raceways 16110 Raceway Systems 16111 Conductors and Cables 16120 Electrical Boxes and Fittings 16135 Supporting Devices 16136 Wiring Devices 16140 Motor Starters 16155 Panelboards 16160 Motor and Circuit Disconnects 16170 Overcurrent Protective Devices 16180 Transformers 16181 Grounding 16452 Interior and Exterior Building Lighting 16510 Telephone Systems 16740 Fire Alarm System 16742 Use of standard industry symbols together with the special symbols, notes, and instructions indicated on the drawings describe the work, materials, apparatus and systems required as a portion of this work. Visit the site during the bidding period 8776/Division 16 16/1 Ricks College Plant Science Basement Remodel TABLE OF CONTENTS PAGE SECTION 16001 - ELECTRICAL GENERAL PROVISIONS 1 SECTION 16070 - ELECTRICAL CONNECTIONS FOR EQUIPMENT 16 SECTION 16110 - CONDUIT RACEWAYS 19 SECTION 16120 - CONDUCTORS AND CABLES 25 SECTION 16135 - ELECTRICAL BOXES AND FITTINGS 27 SECTION 16136 - SUPPORTING DEVICES 30 SECTION 16140 - WIRING DEVICES 32 SECTION 16155 - MOTOR STARTERS 35 SECTION 16160 - PANELBOARDS 38 SECTION 16170 - MOTOR AND CIRCUIT DISCONNECTS 41 SECTION 16180 - OVERCURRENT PROTECTIVE DEVICES 43 SECTION 16452 - GROUNDING 46 SECTION 16510 - INTERIOR AND EXTERIOR BLDG. LIGHTING 48 SECTION 16740 - TELEPHONE SYSTEM (RACEWAYS) 52 SECTION 16744 - COMPUTER SYSTEM & INDICATED CLOCKS 53 SECTION 16800 - AUXILIARY SYSTEMS 54 4. Control Panels: Shall be 14 gauge furniture steel enclosed on all four sides with a hinged door and key lock. The panel shall be shop painted with the manufacturer's standard color. All controllers, relays, time clocks. etc. shall be mounted in the control panels and all electrical devices wired to numbered terminal strips. 5. Zone Controller: Shall be microcomputer based single zone controller. Direct digital control of sixteen adjustments for control of setpoints. setback, setup, high and low limits, and changeover. Johnson C-500-A with Johnson S-500-A staging modules and R-120 relay packs as required. 15928 DESCRIPTION OF SYSTEI: 1. Existing Multi -zone Unit: The two existing zone thermostats in the basement shall be re --piped to control the existing zone dampers as indicated on the drawing. All other controls on this unit shall remain as existing. 2. Existing Single -zone Unit: The existing single zone unit shall receive a new day/night, heating/cooling thermostat to control the heating/cooling operation and changeover of the existing single -zone unit. This new thermostat„ along with a new chilled water valve shall be tied into the existing Johnson C-500-A zone controller. Provide new staging modules and relay packs as required. Re --wire the existing zone controller to handle the new thermostat and cooling valve. 3. New AC-1 Unit: The new AC unit shall have a new Johnson T-960 thermostat. with concealed setpoint.. This unit shall be connected through a new Johnson C-500-A zone controller, with staging modules, and relay packs as required. 15930 _ SE%UENCE OF_CQITR01. 1. Existing Multi -zone Unit: Sequence of control shall not be modified on this unit. 2. Existing Single -zone Unit: Sequence of control shall be modified to control new cooling equipment, and change existing outside air dampers to economizer cycle. All other control sequences shall remain as existing. 3. New AC-1 Unit: The new, T--960 thermostat, shall control the day/night heating/cooling temperature set.point of the new AC unit, and be tied into a new C-500-A zone controller for future connection to Ricks College JC-85 control system. END OF SECTION 15900 8776/Division 15 15/26 Ricks College Plant Science Basement Remodel 15922 AIR PIPING SYSTEM: 1. Pipe shall be seamless copper tubing or non-metallic tubing as specified herein. Non --metallic tubing shall be polyethylene, ASTM Type 1, Grade 5, and Class B or C meeting the stress crack test. ASTM D1693-60T. Polyethylene tubing must, be classified as flame retardant and must be rated as self -extinguishing when tested under ASTM D635 flammability test. 2. Non-metallic tubing -run in mechanical or finished spaces where other tubing is exposed shall be run within adequately supported rigid metallic raceway, EMT, pipe. or duct. 1592A CONTROL COMPONENTS: (PNEUMATIC) Room Thermostats: All thermostats shall be of the two -pipe type. They shall be fully proportional with adjustable throttling range. They shall automatically change from day to night operation on a change in main air pressure. ?. Control Valves: Valves 2 1/2 inches and smaller shall be screwed, 3 inches and larger shall be flanged. They shall have stainless steel stems, replaceable seats and self-adjusting teflon packing. 3. Dampers: Dampers shall be low leakage with inflatable seal edging that, shall be rated for leakage less than 10 cfm per square foot at the system design pressure differential with a holding torque of no more than 50 lbs. The Control Contractor shall furnish all control dampers that are not furnished as a part of mixing boxes. Honeywell D643. d. Control Panels: Shall be 14 gauge furniture steel enclosed on all four sides with a hinged door and key lock. The panel shall be shop painted with the manufacturer's standard color. All controllers, relays, time clocks, etc. shall be mounted in the control panels and all electrical devices wired to numbered terminal strips. 15926 CONTROL COMPONENTS: (ELECTRIC) 1. Room Thermostats: All thermostats shall be of the electric -electronic low voltage type. They shall be fully proportional with adjustable throttling range. They shall automatically change from day to night operation on a change in the time clock. Johnson T-960 2. Control Valves: Valves 2 1/2 inches and smaller shall be screwed. 3 inches and larger shall be flanged. They shall have stainless steel stems, replaceable seats and self-adjusting teflon packing. 3. Dampers: Dampers shall be low leakage with inflatable seal edging that shall be rated for leakage less than 10 cfm per square foot at the system design pressure differential with a holding torque of no more than 50 lbs. The Control Contractor shall furnish all control dampers that are not, furnished as a part of mixing boxes. Honeywell D643 . 8776/Division 15 15/25 Ricks College Plant. Science Basement Remodel 15900 TEMPERATURE CONTROLS: 15902_____WORK INCLUDED: 1. The Automatic Control Contractor shall furnish and install a complete electric -electronic system of automatic temperature control as specified herein and as shown on the contract drawings as manufactured and installed by Johnson Controls. Inc. a. This specification is intended to cover equipment for the automatic temperature control of: New A/C Unit. 2. The Automatic Control Contractor shall furnish all labor, materials. equipment, and services as necessary for the proper installation of a system of automatic control. The temperature control system shall be pneumatic as manufactured and installed by Johnson Controls. Inc. a. This specification is intended to cover equipment for the automatic temperature control of: Existing HVAC Equipment. 15906 SERVICE AND GUARANTEE: I. After completion of the installation, the Automatic Control Contractor shall adjust all thermostats, motors and other equipment provided under his contract. He shall place them in complete operating condition subject to the approval of the Engineer. The control system specified herein shall be free from defects in workmanship and material under normal use and service. If within twelve (12) months from date of acceptance by the Architect and/or Engineer any of the equipment herein described is proved to be defective in workmanship or material, it shall be adjusted, repaired. or replaced free of charge by the Automatic Control Contractor. 15908 ELECTRIC WIRING: I. All wiring in connection with the automatic control systems, including electrical interlock, shall be furnished and installed by the Control Contractor, except as noted on the electrical drawings. All wiring shall be run in EMT conduit and comply with NEC. 15912 SUBMITTALS AND INSTRUCTIONS: 1. The Temperature Control Contractor shall submit to the Engineer for approval the required number of shop drawings of the entire control system before starting work. 2. On completion of the work. the Temperature Control Contractor shall instruct the operating personnel in proper operation of this system. Provide an "as installed" diagrammatic layout of the automatic control system enclosed in a waterproof plastic envelope and posted where directed. 8776/Division 15 15/24 Ricks College Plant Science Basement Remodel 15800 AIR HANDLING: 15801 SCOPE: 1. Required: All plant. labor, equipment, appliances, materials, transportation. facilities and services necessary for and/or reasonah1 incidental to the completion of all air handling work, in conformity ait.h the drawings, the specifications, and the other contract documents. 15816 CENTRIFUGAL EXHAUSTERS: 1. Furnish and install where noted on the plans direct drive or V-belt drive centrifugal exhaust.ers. Ventilator housings shall be of heavy gauge spun aluminum construction and shall be weatherproof, incorporating an integral weather shield. Fan wheels shall be backwardly curbed, non -overloading centrifugal design that have been statically- and dynamically balanced. Tip speed, rpm. and motor horsepower shall not. exceed listing in manufacturer's catalog for unit specified. Fans shall have integral factory formed base fabricated of the dimensions shown on the drawings. Housings shall be provided with wiring channel and are to be of the direct. discharge design. Motor and fan assembly shall be on vibration isolating mounts. Motors shall be of the electrical characteristics shown. Fans shall have capacity speed and motor sizes as listed. Each fan shall be equipped with the following accessories: automatic backdraft damper, birdscreen. Fans shall be Penn, Carnes, ACME. Greenheck, or Cook. END OF' SECTION 1580O 8776/Division 15 15/23 Ricks College Plant Science Basement Remodel A. Frame and Casing: The frame shall be welded construction. The casing shall be of galvanized panels with a baked -on outdoor enamel finish. The entire bottom of cabinet shall be insulated with 1" thick fiberglass. 5. Air Filters: Cleanable filters shall be furnished. Provide two sets for each unit. E%D OF SECTION 15700 8776/Division 15 15/22 Ricks College Plant. Science Basement. Remodel 15700 HEAT TRANSFER: 15701 SCOPE: 1. Required: All plant.. labor. equipment., appliances, materials, transportation, facilities and service.% necessary for and/or reasonably incidental to the completion of all heat transfer work, in conformity with the drawings, the specifications, and the other contract documents. 15705 COOLING COILS: 1. Fins shall be continuous aluminum configurat.ed plate -fin type with full fin collars for accurate spacing and maximum fin -tube contact. 2. Tubes shall be copper expanded into the fin collars for a permanent fin -tube bond and expanded into the header for a leak -tight joint, at 250 psig air pressure under water. 3. Headers shall be gray cast iron hydrostatically tested to 400 psi before assembly. 4. Casings shall be constructed of 16 gauge, continuous coated galvanized steel with fins recessed into the channels to minimize air bypass. Top and bottom channels shall have 3/8" holes on 3" centers for mounting purposes. 5. Testing: All standard coils shall be leak tested at 250 psig air under water. 6. Coils to be McQuay. 15775 PACKAGED HEATING -COOLING UNIT: 1. General: Furnish and 'install an AGA certified one piece combination air-to-air DX mechanical cooling system and electric heating system. complete with automatic controls. The equipment shall be shipped completely assembled, pre -charged, piped and wired internally ready for field connections. Units shall be Lennox or approved equal. Provide factory warranty and factory startup. 2. Cooling System: The coils shall be non-ferrous construction with aluminum fins mechanically bonded to seamless copper tubes. Condenser coil shall have sub -cooling rows. The compressor shall be resiliently mounted, have built-in 3-mode crankshaft lubrication, crankcase heater, discharge temperature limiter, current and temperature sensing motor overloads. The cooling system shall be protected by high and low pressure switches and a 5-minute compressor timed off cycle controller. 3. Air Movers: Twin centrifugal conditioned air blowers shall have permanently lubricated ball bearings, adjustable belt. drive. The condenser fans shall be direst driven. All motors shall have inherent protection devices. 8776/Division 15 15/21 Ricks College Plant Science Basement. Remodel between fixture and floor flange tight with approved fixture setting compound or gaskets. 4. Polish chrome finish at eornrOetion of project. 5. Caulk between fixtures and wall and floor with white butyl rubber non -absorbent caulking compound. Point all edges. 6. Install fixtures and fittings as per local codes and manufactUf'e["'S instructions. 7. Do not use flexible water piping. 115414 FIXTURE SCHEDVLE 1. Furnish and install the necessary plumbing fixtures in quantity as shown on plans. Fixtures to be American Standard, Crane, or Kohler. Before fixtures are ordered, the Contractor shall submit a complete list of plumbing fixtures, giving the catalog number, cut and make. for approval. Fixtures shall not be ordered until this list is approved. Provide all necessary valves, cast "P" traps, stops with risers, fittings, and accessories to make the job complete with the fixtures specified on the drawings. Exposed stops to be equal to Brasscraft with screwed inlet,. chrome plated nipples, cross handles and flexible risers. 2. Fixtures shall be Kohler, Crane, American Standard, or an approved equal. Specialties shall be Zurn, Josam. J. R. Smith, or Wade. Stainless steel sink manufacturers shall be Elkay or Just. Drinking fountain manufacturers shall be Elkay, Halsey Taylor. Haws. Cordley, Sunroc, or Oasis. 3. Provide GSR "Fuseseal" flame retardant acid resisting pipe and fittings - where shown. END OF SECTION 15400 8776/Division 15 15/20 Ricks College Plant Science Basement Remodel recess drainage pattern. Traps installed in connection with cast. iron pipe shall be of the same duality and grade as the pipe. Traps installed in connection with fixtures shall have a seal of not less than 2" nor more than d". Exposed traps shall be chrome plated cast. brass or chrome plated 17 gauge tubular type. Provide trap primers as required by Code. 4. Joints: Make joints between cast. iron piping and fittings with oakum gasket and pig lead. Pour joint full at one pouring and caulk solid. flush with hub. Tyler "Ty -Seal" gasket. is also acceptable. Make joints between east iron and steel pipe same as above. but, installing ring or part of coupling on screwed pipe to form spigot. end. Make screw joints in steel waste and vent pipe with approved pipe paste and with not more than three threads exposed at. finish. Tyler "No -Hub" piping may be used above grade only. 15408 CLEANING SYSTEM: ThoroughIN clean all equipment, piping and all other material controlled under this contract, free from rust, scale and other dirt before and painting or covering is done or the system put in operation. 15410 TESTS: 1. Piping systems shall be subjected to the following tests and no piping shall be covered or concealed until it has been so tested, inspected and approved b_ the Architect and any local inspector having jurisdiction. All piping shall be hydrostatically tested at 50 psi in excess of maximum working pressures. 100 psi minimum. Plumbing waste and drain piping shall be tested by filling with water to the top of a 10-foot riser and left standing for 24 hours without. appreciable drop in water level. 2. When so directed by the Architect and/or Engineer. Contractor shall conduct an operating test on any piece of equipment to demonstrate its capacity and/or operating characteristics. 15412 FIXTURE INSTALLATION: Provide stop valves and 18" minimum air chambers on all water connections to fixtures. Furnish and install wall carriers for wall mounted fixtures. wood backing, where necessary, to be installed by General Contractor at. the direction of' this Contractor. Provide exact locations, including proper mounting heights, obtained from details on drawings and from manufacturer's specifications. Provide hudee rims for countertop installations. 2. Interior exposed pipe, valves, and fixtures trim shall be chrome plated. 3. Complete installation of each fixture including trap and accessories with accessible stop or control valve in each hot and cold water branch supply line Make fixture floor connections with approved brand of cast iron floor flange, soldered or caulked securely to waste pipe. Make joint 8776/Division 15 175/19 Ricks College Plant Science Basement. Remodel 15400 PLUMB I XG : 13402 SCOPE: Required: All plant., labor, equipment. appliances. materials. transportation, facilities and services necessary for and/or reasonably incidental to the completion of all plumbing work, in conformity with the drawings, the specifications, and the other contract documents, including but not. necessarily -limited to the following: a. Complete Domestic Cold Water System b. Complete Domestic Hot. Water System c. Complete Drainage System with Proper Connections to all Drains 2. The contractor shall be responsible to verify and/or change the temperature settings on all water heaters supplied on this project to meet. the requirements of Life Safety and Health Department. Codes. Any setting above 120 deg. F. shall require warning labels placed on the outside of the water heaters in conspicuous places indicating the water temperature setting and the fact that any temperature above 120 deg. F. may be a hazard. 15404_ PIPING INSTALLATION: I. Run main soil pipe and branches to all fixtures. Size piping as shown. Run piping direct and concealed from view, unless otherwise shown. Grade horizontal runs 1/4" to the foot. minimum. Provide sufficient drains to draw water from entire domestic water system and sections thereof where cutoffs are shown. Furnish and install complete hot and/or cold water to all fixtures as shown on drawings. Run lines parallel to each other and parallel with the lines of the building. Cut pipes accurately to required measurements and work into place without springing or forcing. Provide for expansion and contraction of piping. Paint exposed threads on underground piping one coat asphaltum varnish. 15406 MATERIALS: I. Cleanouts: Provide and set full size cleanout.s at foot of each riser. and ends of branches from toilets, at: points where a change of direction occurs, on exposed and accessible traps, at points where required to remove rust accumulation or other obstructions and as shown on plans. Set screw cap in cleanout with graphite paste. Cleanouts in floors shall be flush using Zurn. Josam, or Wade floor level cleanout fittings. Location of all cleanout.s subject to approval of inspector. 2. Vents: Vent lines shall follow soil and waste lines connecting with them above highest fixtures with proper fittings. Carry vents through the roof as shown. 14" minimum heights above roof. Bring together in one stack through roof wherever possible. 3. Traps: Install "P" traps in branch lines from floor drains or where required. Traps installed in connection with threaded pipe shall be 8776/Division 15 15/18 Ricks College Plant Science Basement Remodel etc. provided, however. this Contractor shall furnish to the General Contractor full information as to locations, dimensions, etc., of such chases and openings, including the provision and proper setting of all sleeves and other equipment in advance of construction of the work so as to cause no delay in the work. Should any cutting of walls. floors, ceilings. partitions, etc., be required for proper installation of the work or apparatus of this Contractor due to his failure in giving the General Contractor the proper information at the time required. such cutting shall he done at his own expense and in a manner acceptable to the Architect. -Engineer. All drilling and patching for anchor bolts. hangers, and other supports shall he subject to the approval of the Architect -Engineer. All portions of the system shall he hydrostatically tested. Flushing of underground piping shall be done in accord with National Fire Protection Association Pamphlet No. 13. On completion of the work, the system shall be tested by full flow. Each control valve for each sprinkler system shall he tested by use of an inspector's test valve or the application of heat to the sprinkler head most remote from the valve. All alarms and other devices shall be tested. All appliances and equipment for testing shall be furnished by the Contractor and all expenses, except for water and electricity used in connection with the tests, shall be defrayed & him. On completion of the tests by the Contractor, any defects detected shall be corrected by the Contractor at his own expense and additional tests made until the systems are proved satisfactory. The Contractor shall submit to the Architect. -Engineer a certificate covering materials and tests, similar to that specified in National Fire Protection Pamphlet. No. 13 with a request for formal inspection, at least, two working days prior to the date of inspection. At this inspection, any or all of the required tests shall be repeated as directed b. the Architect --Engineer. 15308 PIPE SIZING: 1. This Contractor shall be required to size all piping for this project in accordance with the requirements of Chapter 7 of the National Fire Protection Association Pamphlet No. 13 for Hydraulically Designed Sprinkler Systems. END OF SECTION 15300 8776/Division 15 15/17 Ricks College Plant Science Basement Remodel sprinklers must be spaced equally with lights and ceiling diffusers. do fabrication of piping shall he done until the piping drawings are accepted by the Mechanical Engineer and the Rating Bureau. 4. Materials and Componont.s: Sprinkler Heads: Sprinkler head orifice sizes shall be in accordance with NF1'A No. 13. Any change in spacing must- be in straight rows with lights and walls. Sprinkler heads shall be automatic and of the conventional (spray) type and shall be approved by a nationally recognized testing; laboratory. Each head shall have an orifice of nominal 1/2" diameter. The sprinkler heads shall he of the pendant, type where installed above a hung ceiling. 5. Interior Piping Valves and Fittings: Sprinkler and standpipe piping shall be standard weight black steel pipe. Fittings shall be cast iron, black. screwed, except where flange fittings are required. Flanged fittings shall be 150 pound class American Standard. All exposed sprinkler piping shall he thoroughly cleaned and given one shop coat of prime coat paint. by Contractor. All pipe hangers and hanger spacings shall be in strict accordance with NFPA Pamphlet No. 13. 6. Valve Signs: Properly lettered approved metal signs shall be attached to each control valve. 7. Sleeves and Floor, Wall and Ceiling Escutcheon Plates: Provide for all sprinkler and standpipe piping passing thru floors, walls, and ceilings approved type one-piece or split -type escutcheon plates. Plates shall abe securely anchored in place with set, screws or other approved positive means. 8. Insta11ation: All work shall be executed and inspected in accord with all laws, ordinances, rules and regulations of local authorities having jurisdiction over such work. The Contractor shall obtain all permits and pay all fees in connection herewith where required. Should any change in the drawings or specifications be required to conform to these ordinances, the Contractor shall notify the Architect -Engineer at the time of submitting his bid. After entering into the contract. Contractor will be held to complete: all necessary work to meet local requirements without, expense to the Owner. The sprinkler system shall be installed such that spacing of the sprinkler heads in relation to the ceiling shall not exceed that permitted for the type of ceiling construction involved. The General Contractor is required under contract stipulations to leave all chases and openings in walls, floors, ceilings, partitions and beams, 8776/Division 15 15/16 Ricks College Plant Science Basement. Remodel 15300 FIRE. PROTECTION: 15302 WORK INCLUDED: This section consists of furnishing all labor, equipment, appliances, and materials and in performing all operations in connection with the installation of fire protection systems. The work shall include, but. is not necessarily limited to. the following systems: Extension of Existing Wet. Pipe Automatic Sprinkling System as required for new remodeling work in Basement and Lobby of First. Floor 15304 APPLICABLE CODES AND ORDINANCES: 1. The following form a part of this specification: National Fire Protection Association Pamphlets: Standards of the National Fire Protection Association for the Installation of Sprinkler and Fire Protection Equipment. Underwriter's Laboratories, Inc. Publications: List of Inspected Fire Protection Equipment. and Materials. Applicable state and local codes and ordinances pertaining to fire protection systems and equipment.. 15306 SPRINKLER SYSTEM, WET PIPE: General: Furnish and install a complete wet pipe sprinkler system as herein described. All work and materials shall conform with the requirements of Pamphlet No. 13 of the National Fire Protection Association and as approved over this geographical area. 2. It shall be the responsibility of the Fire Sprinkler Contractor to verify the adequacy of the water service to the building. He shall also check with the Fire Rating Bureau to determine the requirements of fire hydrants, fire department connections, test connections and exterior and interior piping, water storage and supply, spacing of heads, need for pumps, secondary power source, pump house, and rating of the building. Any and all requirements of the Rating Bureau shall be included as a part. of this contract. 3. Shop Drawings: Shop drawings shall be submitted as required by the Mechanical General Conditions. This Contractor shall submit complete layouts to underwriters having jurisdiction for approval, prior to submission to Architect. Particular attention shall be paid in the layout to the coordination of the sprinkler piping and the structural system of beams. Notations shall be made on the shop drawings where pipes are required to pass thru beams. Wall sprinkler shall be used in ramp areas where headroom is at a minimum and shall be arranged so as not to conflict. with egress and door swings. Careful coordination shall be given to avoid changing ceiling lighting systems as shown on the drawings. All the 8776/Division 15 15/15 Ricks College Plant Science Basement Remodel Finish all fittings and valves with 4 oz. canvas and coat with vapor barrier adhesive unless using Zeston covers. 15273 PREMOLDED ONE PIECE PVC FITTINGS: 1. Premolded one piece PVC insulated fittings may be utilized in accordance with the following specifications. 2. General: Where the -factory Premolded one piece PVC insulating fitting covers are to be used, the proper factory precut. Hi-Lo Temp insulation shall be applied to the fitting. The ends of the Hi-Lo Temp insulation shall be tucked snugly into the throat of the fitting and the edges adjacent to the pipe covering tufted and tucked in, fully insulate the pipe fittings. The one piece PVC fitting cover is then secured by stapling, tack fastening. banding or taping the ends to the adjacent pipe covering. Fittings shall be UL rated 25/50 PVC. 3. Cold: Chilled water systems shall be insulated as above and have all seam edges of cover sealed with Zeston's vapor barrier adhesive or equal. The circumferential edges of cover shall he wrapped with 7eston's vapor barrier pressure sensitive color matched Z tape. The tape shall extend over the adjacent pipe insulation and have an overlap on itself at least 2" on the downward side. 4. Hot.: On fittings where temperature exceeds 250 degrees F., two layers of the factory precut Hi-Lo Temp insulation inserts shall be applied with a few wrappings of twine on first layer, to be sure there are no voids or hot spots. The fitting cover shall then be applied over the Hi-Lo Temp insulation as described alcove in "General." 15278 _ REMOVABLE PRE -MOLDED INSULATION COVERS: 1. Furnish and install Busse Type removable ABS pre -molded Universal "Retrofit -All" insulation covers on steam traps, strainers, orifices, check valves, wyes, cross tees, and other similar type valves. The "Retrofit -All" insulated covers shall be ABS plastic molded two piece boxes with inner preformed section of insulation. The insulation shall be heavy density fiberglass applicable for standard service temperatures from -60 deg. F. to 650 deg. F. to 1000 deg. F. Insulation lines, when tested in accordance with UL 723 and ASTM E84. shall not exceed 25/50 rating. ABS cover shall not support. combustion. END OF SECTION 15250 8776/Division 15 15/14 Ricks College Plant. Science Basement Remodel 15269 STEAM SUPPLY AND CONDENSATE RETURN PIPING: 1. Scope: Insulate piping mains. branches, risers, fittings, valves, pump bodies and flanges. Use 6 Ib./cu.ft. density fiberglass with fire retardant vapor barrier jacket with self-sealing laps. Thickness shall be 1 1/2" on steam and 1" on condensate return lines. Approved manufacturers are Owens-Corning fiberglass heavy density with ASJ-SSL jacket, and equals b, Johns -Manville or CSG. Use Zeston covers for valves and fittings. 2. Pipes: Install in accordance with manufacturer's direction on clean dry pipes. Butt joints firmly together. Seal barrier longit-udinaI seam overlap with vapor barrier adhesive. Wrap butt joints with 4" strip of vapor barrier jacket material cemented with vapor barrier adhesive. Finish with bands applied at mid -section and at each end of insulation. 3. Valves & Fittings: Insulate and finish by one of the following methods: a. With hydraulic setting insulating cement, or equal, to a thickness equal to adjoining pipe insulation. b. With segments of molded insulation securely wired in place. c. With prefabricated covers made from molded pipe insulation finished with vapor barrier adhesive. d. With Zeston covers. Finish all fittings and valves with 4 oz. canvas and coat with vapor barrier adhesive unless using Zeston covers. 15271 CHILLED SUPPLY AND RETURN PIPING: 1. Scope: Insulate piping mains, branches, risers, fittings, valves. pump bodies and flanges. Ise 6 lb./cu.ft. density fiberglass with fire retardant vapor barrier jacket with self-sealing laps, Thickness shall be 1 112". Approved manufacturers are Owens-Corning fiberglass heavy density with ASJ-SSL jacket., and equals by Johns -Manville or CSG. Use Zeston covers for valves and fittings. 2. Pipes: Install in accordance with manufacturer's direction on clean dry pipes. Butt joints firmly together. Seal barrier longitudinal seam overlap with vapor barrier adhesive. Wrap butt joints with 4" strip of' vapor barrier jacket material cemented with vapor barrier adhesive. Finish with bands applied at mid -section and at each end of insulation. 3. Valves & Fittings: Insulate and finish by one of the following methods: a. With hydraulic setting insulating cement, or equal, to a thickness equal to adjoining pipe insulation. b. With segments of molded insulation securely wired in place. c. With prefabricated covers made from molded pipe insulation finished with vapor barrier adhesive. d. With Zeston covers. 8776/Division 15 15/13 Ricks College Plant Science Basement Remodel 115250 —MCHANICAL INSULATIOt 15252 WORK INCLUDED: The installation, shall consist of all insulation work. in conformity with the drawings, the specifications. and other contract documents including, but not limited to, the following: Cold Water Piping Insulation Hot Water Piping Insulation (Domestic) Chilled Water Cooling Steam Piping Insulation 15255 GENERAL RE UIREMEkl'S: I. All insulation shall have composite (insulation. jacket or facing and adhesive used to adhere the facing or jacket to the insulation) fire and smoke hazard ratings as tested by Procedure ASTM E-84. NFPA 255 and lL 723 not exceeding: Flame Spread of 25 and Smoke Developed of 50. 2. Accessories, such as adhesives. mastics, cements, and tapes, for fittings shall have the same component ratings as listed above. All products, or their shipping cartons, shall bear a label indicating that flame and smoke ratings do not exceed above requirements. Any treatment of jacket or facings to impart flame and smoke safety shall be permanent. The use of water-soluble treatments is prohibited. The Insulation Contractor shall certify in writing, prior to installation. that all products to be used will meet the above criteria. 15261 DOMESTIC HOT AND COLD WATER LINES: 1. Scope: Includes insulating of above ground hot and cold water lines. fittings, valves, pump bodies, and flanges. 2. Insulation: Shall be 1" thick snap --on glass fiber pipe insulation. heave density pipe insulation with factory- vapor jacket equal to Fiberglass ASJ may be used. Approved manufacturers are CSG, Johns -Manville, Owens-Corning, and Knauf. 3. Apply insulation to clean, dry piping with joints tightly butted. Adhere "factory- applied vapor barrier jacket lap" smoothly and securely at. longitudinal laps with a white vapor barrier adhesive. Adhere 3" wide self --sealing butt, joint strips over end joints. 4. Insulate fittings with same type and thickness of insulation as pipe. with ends of insulation tucked snugly into throat of fitting and edges adjacent. to pipe insulation tufted and tucked in. Cover insulation with one piece "Zeston" PVC fitting cover secured by stapling or taping ends to adjacent. pipe covering. ALTERNATE METHOD: Insulate fittings with 1" of insulating cement, and vapor seal with 2 1/8" wet coats of vapor barrier mastic reinforced with glass fabric extending 2" onto adjacent insulation. 8776/Division 15 15/12 Ricks College Plant Science Basement Remodel 5. The scope of this work also includes the re -balancing of the 8-zone multizone unit serving the 1977 addition to the Plant. Science Building. All diffusers (approx. 25) shall be re -balanced to the original design. Sheet M-5 of the original plans will be available from Ricks College for this work. 15120 MECHANICAL PAINTING AND IDENTIFICATION: 1. General: This section is subject to the General Conditions of the contract, to the General Mechanical requirements, and relates to other sections of these specifications. 2. Scone of the Work: The intent of these specifications is to furnish a mechanical system which is clean, orderly, and identifiable throughout.. Primary painting of walls, ceilings, ductwork, piping and plenums is covered in the general painting section of these specifications. This Contractor shall color code and identify piping and label and identify mechanical equipment, components, etc. The Mechanical Contractor shall touch up all equipment where the factory paint has been damaged. Repaint entire item where more than 20 percent of the surface is involved. 3. Description of Work: After painting is completed, do the following: Coded Bands: using colored bands and arrows to indicate supply and return, with colored reflective tape by Seaton or equal, color code all piping installed in this contract at, not more than 20-foot intervals, at equipment., at walls, etc. in accordance with ANSI Standards. 4. Pipe Identification: In addition to the colored bands. stencil with black paint in 1/2" high letters a symbol and directional arrow for all fluids handled or use Seaton coded and colored pipe markers and arrows to meet. ANSI Standards. 5. Equipment Identification: Provide an engraved plastic plate for each piece of equipment stating the name of the item, symbol number, and area served. Label all control components with plastic embossed stick -on labels (Dymo). Sample: Supply Fan - North Classrooms 6. Valve Identification: Make a list of and tag all valves installed in this work. Valve tags shall be of brass, not less than 142- size, hung with brass chains. Tag shall indicate plumbing or heating service. END OF SECTION 15100 8776/Division 15 15/11 Ricks College Plant Science Basement Remodel Owner, all air handling systems and appurtenances applicable to the above system shall be adjusted and balanced to deliver the air quantities as specified. indicated on the drawings. or as directed. 2. This Mechanical Contractor shall procure the services of an independent. agency operating under the direction of a registered professional engineer and specializing in the testing and balancing of air systems to perform the balance herein specified. The selection of the independent. agency shall be submitted to the Architect for approval. Instruments required for this air balance shall have been calibrated within a period of six months prior to balancing. Types, serial numbers, and dates of calibration of all instruments shall be listed in the final air balance reports hereafter specified. 3. Method of Balancing and Testing: Air Measurements: Air quantity measurements in main and branch ducts shall be performed by pitot tube traverse of the entire cross sectional area of the duct. Ducts having velocities of 1000 or more feet. per minute shall be measured by inclined manometers (draft gage) or magnehelic gages. Air measurements required for ducts having velocities of less than► 1000 feet per minute shall be performed with micromanometers, hook gage, or similar low pressure instruments. Openings in ducts for pitot tube insertion shall be sealed with snap -in plugs after air balance is complete. Outlet. and inlet air quantities shall be determined by direct. reading velocity meters in accordance with outlet and inlet manufacturer's recommendations. Air Quantity Adjustments: Total air quantities shall be obtained b�, adjustment of fan speeds. Branch duct air quantities shall be adjusted by volume or splitter dampers. Dampers shall be permanently marked after air balance is complete so that. they can be restored to their correct position if disturbed at any time. Volume Adjusters may be used to balance air quantities at outlets and inlets, providing final adjustments do not produce sound levels in excess of heretofore specified limits, or objectionable drafts. Air quantity adjustments by outlet deflectors, grids, or air scoops will not be permitted. Replacement of adjustable pulleys and addition of balancing dampers or pressure taps required to effect proper air balance shall be furnished and installed by this Contractor at no additional cost to the Owner. If requested, the air• balance agency shall conduct any or all of the above field tests in the presence of the Architects representative. 4. Reports: The air balance agency shall record and submit to this Contractor, for forwarding to the Architect for evaluation and approval, four copies of the complete air balance report certified by a registered professional engineer. 8776/Division 15 15/10 Ricks College Plant Science Basement. Remodel 15100 _ BALANCING.. M&O MANUALS, AND I DE I 1 F I C;AT 1 ON : 15102 SCOPE: 1. This work shall include the final adjustment. balancing. and identification of all mechanical systems. The work of this section shall include but not be limited to the following: a. Final testing acid balancing of all mechanical systems. b. Prepare three copies of a mechanical Maintenance and Operation Manual. C. Identification of mechanical piping, valves. ductwork, and equipment. 15107 MECHANICAL MAINTENANCE AND OPERATION MANUALS: The Mechanical Contractor shall prepare three copies of an Operation and Maintenance Manual for all mechanical equipment used in this project.. 2. The manuals shall be bound in hard -backed binders and the front cover and spine of each binder shall indicate the name and location of the project. The following items shall be included in the manual, with any other pertinent data. This list is not complete and is to be used as a guide: a. Provide a master index; at the beginning of the manual showing all items included. Use plastic tab indexes for all sections. Provide a section for each different type of item of equipment. b. The first section of the manual shall consist of names. addresses. and telephone numbers of the Architect,. Mechanical Engineer. Electrical Engineer, General Contractor. Plumbing Contractor, Sheet. Metal Contractor, and Temperature Control Contractor. Provide a List of Suppliers which shall include a complete list of each piece of equipment used with the name, address, and telephone number of vendor. Include a Description of Systems indicating the location of all major equipment and describing the various mechanical systems and the operation and control of these systems, and a suggested maintenance schedule. C. Copy of approved submittal literature for each piece of equipment. d. Maintenance and operation literature published by the manufacturer for each piece of equipment which includes: oiling, lubrication and greasing data; belt, sizes, types and lengths: wiring diagrams; step-by-step procedure to follow in putting each piece of mechanical equipment in operation. e. Parts numbers of all replaceable items. f. Control diagram and operation sequence, along with labeling of control piping and instruments to match diagram. g. Valve chart indicating location on job. h. Contractor's written guarantee. K Air balance and/or water balance reports. 15110 AIR FLOW BALANCE AND TEST: 1. Scone: After completion of the installation of the air conditioning. heating, ventilating and exhaust systems, and prior to acceptance by the 8776/Division 15 15/9 Ricks College Plant Science Basement Remodel 7. Operation Test: At completion, Contractor shall operate the system for a period of at least two days of eight hours each to demonstrate fulfillment. of the requirements of the contract.. During this time. all adjustments shall be made to the equipment so that it is in first-class operating condition. The dampers in all ductwork shall be adjusted so that all outlets handle their proper amount of air. The entire system is to he leftin operating condition acceptable to the architect.. 15083_ ADDITIONAL WORK I. Design is based on equipment as described in the drawing equipment. schedule. And change in toundation bases, electrical wiring. conduit connections, piping, controls and openings required by alternate equipment. spec iIied and submitted and approved shall be paid for by this section. All work shall be in accordance with the requirements of the applicable sections. END OF SECTION 15050 8776/Division 15 1D/8 Ricks College Plant Science Basement Remodel 2. Cleaning Equipment. and Premises: Thoroughly clean all parts of the apparatus and equipment.. Exposed parts which are to be painted shall be thoroughly cleaned of cement. plaster and other materials and all oil and grease spots shall be removed. Such surfaces shall be carefully wiped and all cracks and corners scraped out. Exposed metal work shall be carefully brushed down with steel brushes to remove rust. and other spots and left. smooth and clean. Trap elements shall be removed during cleaning and flushing period. after which they shall be replaced and adjusted. 3. Operating Instructions and Service Manual: The Mechanical Contractor shall prepare three copies of an Operation and Maintenance i"Janual for all mechanical systems and equipment used in this project. These manuals shall be considered a part of the final inspection and shall be submitted for approval at least 30 days in advance of request for final inspection. After, approval of a copy of the. manual by the Architect. the manuals shall be furnished to the Owner for distribution. 4. Tests and Adjustments: No piping work, fixtures, or equipment shall be concealed or covered until they have been inspected and approved by the inspector, who shall be notified when the work is ready for inspection. All work shall be completely installed, tested as required by this section and the city and county ordinances. and shall be leak --tight before the inspection is requested. All tests shall be repeated to the satisfaction of those making the inspections. All water piping shall be flushed out.. tested at 100 psi and shall be left under pressure of supply main or a minimum of 40 psi for the balance of the construction period. 5. Drawings of Record: Two complete sets of blue line mechanical drawings will be provided for the purpose of showing a complete picture of the work as actually installed. These drawings shall serve as work progress report sheets and the Contractor shall make all notations neat and legible therein daily as the work proceeds. The drawings shall be kept at the job at a location designated by the Mechanical Engineer. At completion of the work, these "as -built" drawings shall be signed by the Contractor, dated. and returned to the Architect. 6. Guarantee: All work under this section shall be guaranteed by this Contractor to be free from inherent defects for a period of one year from acceptance. The Contractor shall repair, revise or replace any and all such leaks. failure or inoperativeness due to defective work, materials, or parts free of charge for a period of one year from final acceptance, provided such defect is not, due to carelessness in operation or maintenance. In addition, the Contractor shall furnish all refrigeration emergency repairs, emergency service and all refrigerant required due to defective workmanship, materials, or parts for a period of one year from final acceptance at no cost to the Owner, provided such repairs, service and refrigerant are not caused by lack of proper operation and maintenance. This Contractor shall submit a letter containing these guarantees, with blanks for date of acceptance and date of expiration of guarantees, as part of the final inspection packet. 8776/Division 15 15/7 Ricks College Plant Science Basement Remodel Butterfly Valves: 2" and smaller shall be Milwaukee BB2-100. bronze body, 3505 WOG, stainless steel disc and stem. viton seal. )eves handle. 2 1/2" and larger shall be Milwaukee ML-223-E, lug wafer type, iron body. 2004 WOG with aluminum -bronze disc, 416 S.S. stern. EPDM liner and multi -lock lever. Note: Butterfly valves may be used in lieu of gate. globe. and ball valves where temperature and pressure allow. 4. Hangers. Supports and Anchors: Grinnell and Fee/Mason General: Support components shall conform to Manufacturer's Stand- ardization Society Specification SP-58. Horizontal Piping Installation: Hangers shall adequately support the piping system. They shall be located near or at changes in piping direction and concentrated loads. They shall provide vertical adjustment to maintain pitch required for proper drainage. They shall allow for expansion and contraction of the piping. Use Grinnell Fig. 282 concrete inserts or Fig. 163 pipe hanger flange. Intermediate Attachments: Continuous threaded rod may be used wherever possible. No chain, wire. or perforated strap shall be used. Pipe Attachments: For steel pipe with 1" or less of insulation, use Grinnell Fig. 108 ring and Fig. 114 turnbuckle adjuster or equal. For cast iron pipe, use Grinnell Fig. 260 clevis hanger or equal. For vertical pipe, use Grinnell Fig. 261 or equal. 5. Pipe Sleeves and Inserts: Furnish and install pipe sleeves of either steel or heavy steel metal of the telescoping type of a size to accommodate pipe and covering wherever it passes through floors, walls, or ceilings, and such sleeves should be set before concrete is poured or floors finished. Inserts for units should be placed in the concrete or masonry during construction to avoid cutting of finished work. When and if this becomes necessary. it must be done in accordance with the cutting and patching specifications. 6. Floor and Ceiling Plates: Furnish and install an approved type brass chrome plated ceiling and floor plate on all pipes passing through floors. partitions, and ceilings. 15081 REQUIREMENTS FOR FINAL INSPECTION: I. All of the following items must be completed prior to final inspection. No exceptions will be made and no final payment will be made until all items are completed. 8776/Division 15 15/6 Ricks College Plant Science Basement: Remodel oil applied to male threads only in making up all pipe joint. fittings. Fittings shall be standard weight 300 1 b . malleable iron screwed pa t t,c,rn up to 2 1/2". Piping over 2 1/2" shall be welded with full weld fittings. Victaulic couplings and fittings may be used in lieu of welded, flanged or threaded connections on chilled water, condenser water and hot water heating systems. Grade "E" gaskets shall be used up to a maximum operating temperature of 230 deg. F. Where Victaulic couplings and fittings are used. Victaulic Services 700 and 701 butterfly valves may also be used. All pipe grooving and installation shall be in accordance with manufacturer's latest, recommendations. Condensate Drain Piping: Type —1" copper with sweat fittings or Schedule 40 galvanized steel pipe and fittings. 2. Unions and Connections: Install malleable ground joint unions in hot and cold water piping throughout the system so that any portion can be taken down for repairs or inspections without injury to same or covering. Running threads or, lotig screws will not be permitted in jointing arty pipe. Provide dielectric unions between ferrous and non-ferrous metals. 3. Valves: Crane, Nibco, Jenkins, Stockham or Milwaukee Valves used for cutoff service shall be gate valves equal to the following Milwaukee plate numbers: lip to 2" inclusive ------------------------- No . 148 2 1/2" and larger ------------------------- No. F-2885 Valves used in bypasses and for throttling service shall he globe valves: Up to 2" inclusive-. ------------------------ No. 590 2 1/2" and larger ------------------------- No. 359 Check Valves: Up to 2" inclusive -------------------------- No. 509 2 1/2" and larger ------------------------ No. F-2974 Stop and Waste Cocks: No. F-2885 with 3/4" No. 105 gate valve tapped into pipe on outlet side of main valve. Ball Valves: 2" and smaller for domestic water service shall be Milwaukee BA--100. bronze, screwed. 600Z WOG ball valve with Teflon seats. 2" and smaller for heating hot water service shall be Milwaukee BA- 100, bronze, screwed, 600s? WOG ball valve with Teflon seats. 8776/Division 15 15/5 Ricks College Plant, Science Basement Remodel 1.5071 __- coo 1'ER. 1 10\ I. Cooperate with other crafts in the coordination of work. Promptly respond when notified that construction is ready for the installation of work under this section. Contractor will be held responsible for any delays which might, be caused by his negligence or failure to cooperate with the other Contractors or crafts. 15073_ SUPERV I S 101 1. The Contractor shall have a competent superintendent in charge of the work at all times. Anyone found incompetent shall be removed at once and replaced by someone satisfactory, when requested by the Architect. 1o075 PAINTING: 1. See General Specifications. 15077 MATERIALS SCHENLE : 1. Pipe and Fittings: All piping shall be made in the USA. Waste and Vent - (within building) above grade. 2" or less - Schedule 40 galvanized steel pipe with 125 lb. galvanized cast iron fittings. Waste and Vent. - (within building) 2 1/2" or larger or below grade - Standard weight hub and spigot cast iron soil pipe with standard weight. cast iron fittings. All soil pipe and fittings shall bear the seal of the Cast Iron Institute. Acid Resistant. Soil Pipe: Designated AR shall be corrosion acid resisting Pyrex glass and fittings or GSR Yuseal" polypropylene. Exposed waste, vent and water piping connections to fixtures shall be chrome plated. Potable Hot and Cold Water Piping: Above slab shall be Type "L" copper tubing with wrought copper solder fittings. Solder with Silvaloy, Streamline 122, Phos-Copper or approved equal 95/5 solder. Steam Supply Piping and Chilled Water Piping: Schedule 40-A-120 black steel piping. Ends of all pipe shall be reamed out before being made up into fittings. Use graphite and oil applied to male threads only in making all pipe joint fittings. Fittings shall be standard weight. 150 lb. malleable iron screwed pattern up to 2 1/2". Piping over 2 1/2" shall be welded with full weld fittings. High Pressure Steam Piping: Schedule 40-A-53 grade B black steel pipe with 300 pound fittings. Condensate Piping: Schedule 80 black steel piping. Ends of all pipe shall be reamed out before being made up into fittings. Use graphite and 8776/Division 15 15/4 Ricks College Plant. Science Basement. Remodel relays, push buttons and pilot. light.s. thermal overload switches, connections of line and control conductors for motors, etc., shall be. supplied, installed and connected Ity the Electrical Contractor as specified under- the electrical section of the specifications. 2. where motor starters, relays and controls, etc., are factory assembled into packaged units, they shall be furnished by the Mechanical Contractor under this section of the specifications. 3. Pressure switches, valves, float, switches. et.c.. will be supplied and installed by the Mechanical Contractor under this section of the specifications and connected by the Electrical Contractor. This Contractor shall furnish the Electrical Contractor with the necessary wiring diagrams for this equipment. 15065 EXCAVATION AND BACKFILL: 1. Excavation: The Contractor shall do all necessary excavation of wl►atever substance encountered for proper laying of all equipment. Excavated materials not required for fill shall be removed from the site as directed by the Engineer. Excess excavation below required level shall be. backfilled at the Contractor's expense with earth, sand, or gravel as directed by the Engineer and thoroughly tamped. Ground adjacent to all excavations shall be graded to prevent. water running in. 2. Backfilling: The Contractor shall do all backfilling of trenches. allowing for settlement. Backfill shall be mechanically compacted to same density as surrounding undisturbed earth. Cinders shall not be used in backfilling where steel or iron pipe is used. No backfilling shall be done until installation has been approved by the Engineer. 15067 STORAGE AND PROTECTION OF MATERIALS: Provide own storage space for storage of materials and assume complete responsibility for, losses due to any cause whatsoever. Storage shall not interfere with traffic conditions in any public thoroughfare. 2. Protect completed work, work underway, and materials against loss or damage. 3. Close pipe openings with caps or plugs during installation. Cover fixtures and equipment; and protect against dirt., or injury caused by water, chemical, or mechanical accident. 15069 CUTTING AND PATCHING: 1. All necessary cutting and patching of walls, floors, partitions, ceilings, etc., as required for the proper installation of the work under the contract. shall be done at the expense of this Contractor. No joists. beams. girders, or columns shall be cut by any Contractor without obtaining written permission from the Architect. 8776/Division 15 15/3 Ricks College Plant Science Basement Remodel opening. A schedule showing make, type, manufacturer's name and trade designation of all materials and equipment proposed as a substitution shall be submitted. together, with a single copy- of the manufacturer's complete specification. A list of approved substitutions will be published as an addendum. 3. Within thirty days after award of contract, this Contractor shall submit. ten (10) sets of submittals showing make. type, manufacturer's name and trade designation of -all materials and equipment he proposes to use and furnish. This submittal shall be accompanied by the manufacturer's complete specification (ten copies) for equipment items or materials used. Give complete information as to capacities. ratings. kind of material used. finish. guarantee, etc., and such dimensions as are necessary to check space requirements. when approved. such submittal and drawings shall be an addition to these specifications and shall be in equal force in that no variation shall be permitted. The Architect is to be the sole judge as to the quality of any material offered as an equal. 15057 MECHA\ 1 CAL DRAW 1 NGS : The mechanical drawings do not attempt to show complete details of the building construction which affect the mechanical installation. This Contractor shall refer to the architectural. structural, and electrical drawings for additional building detail which affect installation of his work. 2. Diagrams showing piping and/or duct connections are diagrammatic only and do not, attempt to show exact details. No extra payments will be allowed where piping and/or ductwork must. be offset. to avoid other work or where minor changes are necessary to facilitate installation. 3. Everything shown on the mechanical drawings shall be the responsibility of the Mechanical Contractor unless specifically noted otherwise. 15059 FIELD MEASUREMENTS: 1. Verify all measurements at the building and become fully acquainted with the existing conditions before beginning work. 15061 CODES, INSPECTIONS AND PERMITS: 1. Work shall be executed and inspected in accordance with local codes and ordinances. Permits, fees, or charges for inspection or other services shall be paid for by this Contractor. Local codes and ordinances are to be considered as minimum requirements and must. be properly executed without expense to Owner, but do not relieve the Contractor from work shown that. exceeds minimum requirements. 15063 ELECTRICAL WORK: 1. Provide and install electrical motors required for equipment specified in this section of the specifications. Motor disconnects. motor starters. 8776/Division 15 15/2 Ricks College Plant Science Basement. Remodel 15000 DIVISION 15 - MECHANICAL: 15050 MECHANICAL GENERAL REQ1.IREMENTS: 15051 SCOPE: 1. The General Conditions are a part of this section. 2. Required: All plant,. labor, equipment, appliances, materials, transportation, facilities, and services necessary for and/or reasonably incidental to the completion of all mechanical work. in conformity with the drawings, the specifications. and the other contract documents, including but: not necessarily limited to the following: 15100 BALANCING. M&O MANUALS, AND IDENTIFICATION 15250 MECHANICAL INSULATION 15300 FIRE PROTECTION 15400 PLUMBING 15700 HEAT TRANSFER 15800 AIR HANDLING 15850 AIR DISTRIBUTION 15900 TEMPERATURE CONTROLS 15053 APPLICABLE SPECIFICATIONS: 1. Specifications, standards, and publications referenced hereafter shall l.-te of the issues in effect on date of Advertisement for Bid. Applicable city and/or state plumbing laws and regulations. "Heating. Ventilating and Air Conditioning Guide" published by the American Society of Heating and Air Conditioning Engineers. "Engineering Standards" published by the Heating, Piping, and Air Conditioning Contractors National Association. "Uniform Building Code". "uniform Mechanical Code". "uniform Plumbing Code" and "Uniform Fire Code" as published by the International Conference of Building Officials. "National Electrical Code" as published b� the National Fire Protection Association. 15055 SUBSTITUTIONS: 1. By specific designation and description, standards are established for specialties and equipment. 2. Other makes of specialties and equipment. of equal quality will be considered provided such proposed substitutions are submitted to the Architect for his approval at least five working days prior to bid 8776/Division 15 1�/l Ricks College Plant Science Basement Remodel 15700 HEAT TRANSFER: . . . . . . . . . . . . . . . . . . . . 15/21 15701 SCOPE: . . . . . . . . . . . . . . . . . . . . . . 15/21 15705 COOLING COILS: . . . . . . . . . . . . . . . . . . 15 / 21 15775 PACKAGED HEATING --COOLING UNIT: . . . . . . . . . . 15/21 15800 AIR HANDLING: . . . . . . . . . . . . . . . . . . . . 15/23 15801 SCOPE' . . . . . . . . . . . . . . . . . . . . . 15!''" 15816 CENTRIFUGAL EXHAI-STERS: . . . . . . . . . . . . . 15/23 15900 TF.MPERATIRE CONTROLS: . . . . . . . . . . . . . . . . 15/24 15902 WORK INCLUDED: . . . . . . . . . . . . . . . . . 1590E, SERVICE AND Gl "ARANTEE : . . . . . . . . . . . . . 15908 ELECTR 1 C: W I R I NG : . . . . . . . . . . . . . . . . 15912 Sl :B"11 TTALS .A\D I NSTRLiCT I ONS : . . . . . . . . . . . 15922 AIR PIPING SYSTEM: . . . . . . . . . . . . . . . . 15/25 15924 CONTROL COMPONENTS: (PNEU%1A'1' 1 C) . . . . . . . . . 15/25 15920 CONTROL COMPONENTS: (ELECTRIC) . . . . . . . . . 15/25 15928 DESCRIPTION OF SYSTEM: . . . . . . . . . . . . . . 1.=,/2t, 15930 SEQ1FENCE OF CONTROLS: . . . . . . . . . . . . . . 15/26 8776/Division 15 Index/2 Ricks College Plant Science Basement Remodel 15000 DIVISION 15 - MECHANICAL: . . . . . . . . . . . . . . . . 15111 15050 MECHAN I CAI. GENERAL REQI' I REMENTS : . . . . . . . . . . . 15 / 1 15051 SCOPE . . . . 15/115053 APPLA CABL.E SPEC 1 F I CATIONS : . . . . . . . . . . . . I J / _i 15055 SUBSTITUTIONS: . . . . . . . . . . . . . . . . . . 15/1 15057 MECHANICAI_ DRAWINGS: . . . . . . . . . . . . . . . 15/2 15059 FIELD MEASUREMENTS: 15/2 15061 CODES, INSPECTIONS AND PERMITS: . . . . . . . . . 15/2 15063 ELECTRICAL WORK: . . . . . . . . . . . . . . . . . 15/2 15065 EXCAVATION AND BACKF 111: . . . . . . . . . . . . . 15/3 15067 STORAGE AND PROTECTION OF' MATERIALS: . . . . . . . 15/3 15069 CUTTING AND PATCHING: . . . . . . . . . . . . . . 1-5/3 15071 COOPERATION: . . . . . . . . . . . . . . . . . . . 15/4 15073 SI PERV I S l O\ : . . . . . . . . . . . . . . . . . . . 15 / -1 1507-3 PAINTING: 1-3/4 15077 MATERIALS SCHEDULE: . . . . . . . . . . . . . . . 15/4 15081 REQUIREMENTS FOR FINAL INSPECTION: . . . . . . . . 15/6 15083 ADDITIO\AL WORK : . . . . . . . . . . . . . . . . . 15/8 15100 BALANCING, M&O MANUALS. AND IDENTIFICATION: 15/9 15102 SCOPE: . . . 15/9 15107 MECHANICAL MAINTENANCE AND OPERATION MANUALS: 15/9 15110 AIR FLOV BALANCE AND TEST: . . . . . . . . . . . . I:5/9 15120 MECHANICAL PAINTING AND IDENTIFICATION: . . . . . 15/11 1.5250 MECHANICAL INSIALAT10'N: . . . . . . . . . . . . . . . . 15/12 15252 WORK I NCLI DED : . . . . . . . . . . . . . . . . . . 15 / 12 15257 GENERAL REQ(IREMENTS: . . . . . . . . . . . . . . 1-:)/12 15261 DOMESTIC HOT AND COLD WATER LINES: . . . . . . . . 13/12 15269 STEAM SUPPLY AND CONDENSATE RETURN PIPING: . . . . 15/13 15271 CHILLED SUPPLY AND RETt-RN PIPING: . . . . . . . . 15/13 15273 PREMOLDED ONE PIECE PVC FITTINGS: . . . . . . . . 15/14 15278 REMOVABLE PRE -MOLDED INSULATION COVERS: . . . . . 15/14 15300 FIRE PROTECTION: . . . . . . . . . . . . . . . . . . . 15/15 15302 WORK I NCLI "DED : . . . . . . . . . . . . . . . . . . 15304 APPLICABLE CODES AND ORDINANCES: . . . . . . . . . 15/15 15306 SPRINKLER SYSTEM, WET PIPE: . . . . . . . . . . . 15/15 15308 PIPE SIZING: . . . . . . . . . . . . . . . . . . . 15/17 15400 PLUMBING: . . . . . . . . . . . . . . . . . . . . . . 15/18 15402 SCOPE: . . . . . . . . . . . . . . . . . . . . . . 1:)/ 18 15404 PIPING INSTALLATION: . . . . . . . . . . . . . . . 15/18 15406 MATERIALS: . . . . . . . . . . . . . . . . . . . . ] 5 / 18 15408 CLEANING SYSTEM: . . . . . . . . . . . . . . . . . 15119 1-3410 TESTS: . . . . . . . . . . . . . . . . . . . . . . 15/19 15412 FIXTURE INSTALLATION: . . . . . . . . . . . . . . 15/19 15414 FIXTURE SCHEDULE: . . . . . . . . . . . . . . . . 15/20 8776/Division 15 Index/1 Rinks College Plant Science Basement Remodel Apply additional coats when undercoats, stains or other conditions show through final paint coat, until paint film is of uniform finish, color and appearance. Paint surfaces behind movable equipment and furniture same as similar exposed surfaces. Paint surfaces behind permanently fixed equipment or furniture with prime coat only before equipment is installed. Paint interior surfaces of ducts, where visible through registers or grilles, flat, non—specular black. Paint back sides of access panels, and removable or hinged covers to match exposed surfaces. Finish exterior doors on tops, bottoms and edges same as exterior faces, unless otherwise indicated. Sand lightly between succeeding enamel or varnish coats. Omit first coat (primer) on metal surfaces which have been shop —primed and touch—up painted, unless otherwise specified. Apply prime coat to material which is required to be painted or finished, and which has not been prime coated by others. Apply each material at not less than manufacturer's recommended spreading rate, to provide a total dry film to thickness of not less than 4.0 mils for entire coating system of prime and finish coats for 3—coat work. Provide a total dry film thickness of not less than 2.5 mils for entire coating system of prime and finish coat for 2—coat work. Completed Work: Match approved samples for color, texture and coverage. Remove, refinish or repaint work not in compliance with specified requirements. END OF SECTION 09900 8776/PAINTING 09900 — 3 RICKS COLLEGE/ PLANT SCIENCE REMODEL Protection: Protect work of other trades. Correct any painting related damages by cleaning, repairing or replacing, and refinishing, as directed by Architect. Coordination: Provide finish coats which are compatible with prime paints used. Provide barrier coats over incompatible primers where required. Notify Architect in writing of anticipated problems using specified coatings with substrates primed by others. Surface Preparation: Perform preparation and cleaning procedures in strict accordance with coating manufacturer's instructions for each substrate condition. Remove hardware and accessories, machined surfaces, plates, lighting fixtures and similar items in place and not to be finish —painted or provide surface —applied protection. Reinstall r4moved items and remove protective coverings at completion of work. Prepare cementitious surfaces of concrete, concrete block and similar materials to be painted by removing efflorescence, chalk, dust, dirt, grease and oils, and by roughing to remove glaze. Determine alkalinity and moisture content of surfaces to be painted before beginning painting. Do not paint over surfaces where alkalinity or moisture content exceeds manufacturer's recommendations. Seal wood required to be job —painted. Prime edges, ends, face, undersides and backsides of counters, cases, cabinets, counters, etc. Use spar varnish for backpriming where transparent finish is required. Backprime interior paneling only where masonry, plaster, or other wet wall construction occurs on backside. Seal tops, bottoms, and cut—outs of wood doors with heavy coat of varnish or similar sealer immediately upon delivery to job. Clean ferrous surfaces which are not galvanized or shop —coated. Remove oil, grease, dirt, loose mill scale and other foreign substances by solvent or mechanical cleaning. Touch—up shop — applied prime coats wherever damaged. Clean galvanized surfaces free of oil and surface contaminants with non —petroleum based solvent. Material Preparation: Mix, prepare, and store painting and finishing materials in accordance with manufacturer's directions. Application: Apply painting and finishing materials in accordance with manufacturer's directions. Use applicators, and techniques best suited for materials and surfaces to which applied. 8776/PAINTING 09900 — 2 MT MOM crTVWi V lDVMf1T1F.T. SECTION 09900 — PAINTING Submittals: Prior to beginning work, Architect will furnish color chips for surfaoaa to ba Fiaiiitat Ir► aa�itiort to marmfaot'arEriz, data, application instructions, and label analysis for Each coating material, submit samples for Architect's review of color and texture only. Resubmit samples if requested until required sheen, color and texture is achieved. On 12" x 12" hardboard, provide 2 samples of each color and material, with texture to simulate finish conditions. On wood surfaces, provide two 4" x 8" samples for natural and stained wood finish. On concrete masonry, provide two 4" square samples of masonry for each type of finish and color, defining filler, prime and finish coats. On actual wall surfaces and other building components, duplicate painted finishes of acceptable samples, as directed by Architect. Description of Work Painting and finishing of interior and exterior items and surfaces, unless otherwise indicated. Includes field painting of bare and covered pipes and ducts (including color coding), and hangers, exposed steel and iron work, and primed metal surfaces of equipment installed under mechanical and electrical work. Paint exposed surfaces, except as otherwise indicated, whether or not colors are designated. If not designated, colors will be selected by Architect from standard colors available for the coatings required. Work Not Included: Unless otherwise indicated, shop priming of ferrous metal items and fabricated components are included under their respective trades. Pre -finished items, such as metal toilet partitions, acoustic material and the like, are not included. Unless otherwise indicated, painting not required on surfaces of concealed areas except for piping, equipment and other such items within the concealed spaces. Finished metals such as anodized aluminum, stainless steel, bronze, and similar metals will not be painted. Do not paint any moving parts of operating units, or over any equipment identification, performance rating, name or nomenclature plates or code -required labels. Delivery and Storage: Deliver materials to job site in new, original, and unopened containers bearing manufacturer's name, trade name, and label analysis. Store where indicated in accordance with manufacturer's instructions. Job Conditions: Do not apply paint in snow, rain, fog or mist or when relative humidity exceeds 85%. Do not apply paint to damp or wet surfaces. 8776/PAINTING 09900 - 1 RICKS COLLEGE/ PLANT SCIENCE REMODEL Manufacturer: Subject to compliance with requirements, provide products by one of the following manufacturers: Burke Flexco Roppe Installation: Comply with flooring manufacturer's recommendations for type(s) of materials, project conditions, and intended use. Clean floors and apply leveling compound and substrate primer if required, in accordance with flooring manufacturer's instructions. Place resilient flooring continuously under locations of movable partition systems. Lay tile flooring from center marks established with principal walls; adjust as required to avoid use of cut units less than 1/2 tile wide at perimeters. Match tiles for color ana pattern by using in manufactured and packaged sequence. Lay the with grain running in same direction. Apply wall base in lengths as long as practicable to walls, columns, and all permanent fixtures where indicated. Mitered outside corners not acceptable. On masonry or other irregular surfaces, fill voids behind base and along top edge with manufacturer's recommended adhesive filler. At stairways, apply resilient accessories in strict compliance with manufacturer's installation instructions. Fill voids at nosing with epoxy calk. Install resilient edge strips at edges of resilient flooring which would otherwise be exposed. Clean floors and accessories after installation and apply protective polish in accordance with flooring manufacturer's instructions. Omit polish on "no -wax" flooring and tile indicated for "no -wax maintenance". END OF SLV SECTION 09650 6776\RESILIENT FLOORING 09650 - 2 RICKS COLLEGE/ PLANT SCIENCE REMODEL SECTION 09650 - RESILIENT FLOORING Submittals: With manufacturer's product data and installation instructions, submit the following: Samples of each type, color and pattern of resilient flooring and accessories.; full size for tile, 6" x 9" for sheet flooring, and 6" long for accessories. Maintenance instructions for each type of flooring. Replacement material in the amount of one box for every 50 installed for til@ dhd § lih§af yafdF3 16F §h@@t €166€jttg: i6z each type, color and pattern. Colors and Patterns: As scheduled or shown, or as selected by Architect from manufacturer's standard colors and patterns. Vinyl Composition Tile: FS SS-T-312, Type IV, composition as indicated below; 12" x 12" x 1/8" gage unless otherwise indicated. Composition 1 - asbestos free. Manufacturer: Subject to compliance with requirements, provide products by one of the following manufacturers: Azrock Kent i le Tarkett Inc. Rubber Wall Base: FS SS-W-40, Type I; 4" high; 1/8" gage; with matching end stops and preformed corner units; standard top -set cove; unless otherwise indicated. Resilient Stair Treads: Single -piece units for width of stair or equal -length units if tread width exceeds available manufactured lengths. Provide rubber treads, FS RR-T-650, Type A, Class 1; size and style indicated. Resilient Stair Risers: Single -piece risers for height and width of stair risers, or equal -sized units if riser width exceeds available manufactured lengths. Provide rubber risers to match treads. Resilient Edge Strips: Not less than 1" width; 1/8" gage.; tapered bullnose edge, color to match flooring or as selected by Architect. 8776\RESILIENT FLOORING 09650 - 1 RICKS COLLEGE/ PLANT SCIENCE REMODEL Acrylbond TA 365; H. B. Fuller Co. Laticrete 3701 for setting bed and grout, 4237 for bond coat; Laticrete International, Inc. Hydroment Multipurpose Acrylic Latex Additive; Upco Division, Emhart Corp. Water: Potable, neutral ph. Resin Mortar for Joints: ASTM C 395, of resin and filler type indicated below: Resin and Filler Type: High adhesive furan, carbon -filled. Miscellaneous Materials: Sealer: Phenolic -type of acrylic base, non -slip, clear. Set brick in patterns indicated with uniform joints of width indicated. Expansion and Control Joints: Of width and at locations indicated. Sealant work is specified in Division 7. Latex -Modified Portland Cement Applications: Comply with printed directions of liquid latex mortar additive manufacturer for installation of brick by method indicated below: Thick -bed method. Portland Cement Applications: Comply with ASTM C 398. Tilesetter'sMethod: Comply with ASTM C 723. Combination Cement Bed and Resin Grout Applications: Comply with ASTM C 398 for applications of brick in hydraulic cement mortar setting bed and with ASTM C 723 for grouting joints with resin grout of type indicated. Repair, point, clean and protect brick flooring to comply with referenced standards, and manufacturer's directions. Seal and wax cleaned brick surfaces. END OF SLV SECTION 09635 8776\BRICK FLOORING 09635 - 2 SECTION 09635 - BRICK FLOORING Submittals: With manufacturer's technical data and installation instructions for brick flooring, submit 3 samples of each type, color and texture of exposed brick required. Submit cured samples of each type of colored grout. Colors and Textures: As indicated, if not otherwise indicated, as selected by Architect from manufacturer's standard colors and textures. Light Traffic Paving Brick: ASTM C 902; solid (uncored) brick of size, class, type and application indicated. Class SX, Type I: Product: Subject to compliance with requirements, provide the following, or approved equal: Interpace paver, 1" x 8" x 8", nominal. Pre -wax exposed surface where resin -based mortars and grouts are indicated. Materials for Portland Cement Applications: Aggregate: ASTM C 144. Portland Cement: ASTM C 150, Type I. Color: Natural or white to produce required color of grout. Colored Pigmented Grout: Factory -prepackaged mixture of cement, fine aggregates and color fast pigments formulated for mixing with liquid latex admixture. Products: Subject to compliance with requirements, provide one of the following: TA 660 Joint Filler Floor Grout; H.B. Fuller Co. Laticrete Floor Grout and Joint Filler; Laticrete International Inc. Hydroment Grout; Upco Division, Emhart Corp. Customs Building Products. Liquid Admixture for Setting Bed, Bond Coat and Grout: Acrylic resin or styrene butadiene rubber formulations in factory -diluted or concentrated form, designated by manufacturer for use with thick -bed mortar, bond coat and grout applications. Products: Subject to compliance with requirements, provide one of the following: 8776\BRICK FLOORING 09635 - ' Metal Direct -Hung Suspension Systems: Direct -hung systems, roll - formed from prefinished cold -rolled steel sheet, with hanger wire, attachment devices and edge moldings and trim. Non -Fire -Resistance -Rated Exposed Double Web Steel Suspension System with 9/16" Wide Exposed Faces: Structural Classification: Intermediate -Duty System. Finish: Painted, white. Carrying Channels: 1 1/2" steel channels, hot -rolled or cold -rolled. Not less than 0.475 lbs. per lin. ft. Manufacturer: Subject to compliance with requirements, provide products of one of the following: Chicago Metallic Corporation. Donn Corporation. Eastern Products Div., Armstrong World Industries, Inc. National Rolling Mills, Inc. Instal lat ion: Layout: Balance ceiling borders on opposite sides, using more - than -half -width actual units. Tolerance: 1/8" in 12'-0" level tolerance. Pattern Direction: One-way, align joints. Suspension System: Secure to building structure, with hangers spaced 4'-0" along supported members. Edge Moldings: Secure to substrate with screw anchors spaced 16" O.C. Miter corner joints. Cope exposed edges of intersecting exposed suspension members to produce flush intersections. Install acoustical tile with spline (or suspension flange) or tongue and groove at each joint. END OF SLV SECTION 09510 6776\ACOUSTICAL CEILINGS 09510 - 2 RICKS COLLEGE/ PLANT SCIENCE REMODEL SECTION 09510 - ACOUSTICAL CEILINGS General: Acoustical Panel and Tile Standard: FS SS-S-118. Acoustical Suspension System Standards: ASTM C 635 for materials, ASTM C 636 for installation. Surface Burning Characteristics: 25 or less for flame spread, 50 or less for smoke developed, per ASTM E 84. Fire -Resistance -Ratings: As determined per ASTM E 119 and as indicated by reference to design designations in UL "Fire Resis- tance Directory". Submittals: In addition to submission of product data for each type of acoustical ceiling unit and suspension system required, submit the following: 6" square samples of each type of acoustical unit required. Set of 12" long samples of exposed runners and moldings. Deliver extra materials to Owner. Furnish extra materials matching products installed and equaling 2.0% of acoustical units and exposed suspension members installed. Package materials in protective covering and identified with appropriate labels. Products: Mineral Composition Panels - Nodulated, Cast or Molded; with Standard Washable Painted Finish: Fissured Pattern: Color/Light Reflectance: STC Range: 40-44. Edge Detail: Square. Size: As indicated. White/LR 1 (7596 and over). Products: Subject to compliance with requirements, provide one of the following: "Second Look" I Lay -in, Armstrong World Industries, Inc. "Safetone"-White "Hytone" Customline Mosaic CL 812; Celotex Corp., Jim Walter Co. "Auratone" Illusion Eight/12 Omni Fissured, USG Acoustical Products Co. - 8776\ACOUSTICAL CEILINGS 09510 - 1 RICKS COLLEGE/ PLANT SCIENCE REMODEL thin —set tile and similar rigid applied finishes at tubs, �r showers, and similar "wet" areas. Screw gypsum board to wood supports. Screw gypsum board to metal supports. Screw both layers to supports where double —layer work is indicated or otherwise required. Direct Bonding: Comply with manufacturer's recommendations where gypsum board is indicated to be directly bonded to substrate. Do not bridoe building expansion joints. Leave space of the width indicated between boards. Apply compounds indicated below at accessory flanges, penetrations, fastener heads and surface defects. Drywall Finishing: Apply joint tape and joint compound 6t joints between gypsum boards. Apply compounds indicated below at accessory flanges, penetrations, fastener heads and surface defects. Install compound in 3 coats (plus prefill of cracks where recommended by manufacturer); sand between coats and after last coat. Embedding and First Coat: Ready —mix drying type all— purpose of taping compound. Fill (Second) Coat: Ready —mix drying type all—purpose or topping compound. Fill (Third) Coat: Ready —mix drying type all—purpose or topping compound. Treat water—resistant gypsum backing board joints with tape and setting —type joint compound to comply with gypsum board manufacturer's directions. Treat water—resistant gypsum board joints, fastener heads, out edges and penetrations in water—resistant backing board to comply with gypsum board manufacturer's directions. END OF SECTION 09250 8776/GYPSUM DRYWALL 09250 — 4 RICKS COLLEGE/ PLANT SCIENCE REMODEL Sound Attenuation Blankets: fiber blanket insulation. Execution: ASTM C 665, Type I, unfaced mineral Install steel framing to comply with ASTM C 754 and ASTM C 840. Do not bridge building expansion joints with support systems, frame both sides of joints with furring or other supports as indicated. Secure hangers to structural support by connecting directly to structure where possible, otherwise connect to inserts or other anchorage devices or fasteners as indicated. Install direct -hung grid suspension system, including perimeter wall track or angle, with members spaced and installed to comply with manufacturer's instructions. Space furring members 16" o. c. Install steel studs with bottom and top runner tracks anchored to substrates. Isolate system from building structure to prevent transfer of loading and deflections into metal support system, both vertically and horizontally. Frame door and other openings with studs and runners and gage, number and arrangement to comply with manufacturer's recommenda- tions for size of opening, weight of doors and height and stud size, unless otherwise indicated. Install thermal insulation and Z-furring members to comply with manufacturer's directions. Install supplementary framing• runners, furring, blocking and bracing at openings and terminations in gypsum drywall and where required for support of other work which cannot be adequately supported on gypsum board alone. Install and finish gypsum board to comply with ASTM C 840 and as follows: Form "Floating" construction for gypsum boards at internal corners, except where special isolation or edge trim is indicated. Isolate drywall construction from abutting structural and masonry work; provide edge trim and acoustical sealant as recommended by manufacturer. Install sound attenuation blankets where indicated, without gaps; and support where necessary to prevent movement or dislocation. Install water-resistant backing board where indicated to receive 8776/GYPSUM DRYWALL 09250 " 3 RICKS COLLEGE/ PLANT SCIENCE REMODEL Steel Rigid Furring Channels: ASTM C 645, 0.0179 inch base lr' metal thickness, hat -shaped. Where shown as "Resilient provide manufacturer's special type designed to reduce sound transmission. Z-Furring Members: Zee -shaped, 0.0179 inch base metal thick- nessr steel, galvanized, ASTM A 525, G60; for mechanical attachment of insulation, to masonry/concrete walls. Gypsum Board: Provide gypsum board of types indicated in maximum r lengths available to minimize end -to -end joints. Type: Type X. Edges: Tapered. Trim Accessories: ASTM C 840; manufacturer's standard trim accessories, including cornerbead and edge trim of beaded type with face flanges for concealment in joint compound except where semi - finishing or exposed type is indicated. Provide corner bead formed from zinc alloy. Provide one-piece control joints with 1/4 inch wide by 7/16 inch deep vee-shaped slot, covered with removable tape, of roll - formed zinc or extruded vinyl as recommended by gypsum board manufacturer. Gypsum Board Joint Treatment Materials: ASTM C 475 and ASTM C 840, and as follows: Joint Tape: Paper reinforcing tape. Drying -Type Joint Compound: Factory -prepackaged vinyl -based products complying with the following requirements: Ready -Mix Formulation: Factory -premixed product. Taping compound formulated for embedding tape and first coat over fasteners and flanges of corner beads and edge trim. Topping compound formulated for fill (second) and finish (third) coats. Miscellaneous Materials: As follows, recommended by gypsum board manufacturer: Gypsum Board Screws: ASTM C 1002. Gypsum Board Nails: ASTM C 514. Concealed Acoustical Sealant: Comply with requirements specified in Division-7 Section "Joint Sealers". 6776/GYPSUM DRYWALL 09250 - 2 flTf YC r-nT_T.7r:Ti:1 PT.ANT grTFNCE REMODEL SECTION 09250 - GYPSUM DRYWALL General: Fire -Resistance Rating: Provide gypsum drywall construction fire - resistance ratings indicated, conforming to assemblies tested per ASTM E 119 by inspecting and testing organization acceptable to authorities having -jurisdiction. Products: Manufacturer: Subject to compliance with requirements provide gypsum board and related products of one of the following: Centex American Gypsum Co. Domtar Gypsum Co. Georgia-Pacif is Corp. Gold Bond Building Products Div., National Gypsum Co. United States Gypsum Co. Steel Framing Components for Suspended Ceilings: As follows, sized per ASTM C 754, unless otherwise indicated: Cold -Rolled Steel Channels: 0.0598 inch thickness of base metal and 7/16 inch wide flanges, protected with rust -inhibitive paint, and as follows: Carrying Channels: 1-1/2 inches deep, 475 lbs per 1000 ft. Furring Channels: 3/4 inch deep, 300 lbs per 1000 ft. Wires for Hangers and Trim: ASTM A 641, soft, Class 1 zinc coating. Concrete Inserts: Embedded type capable of sustaining a load equal to 3 times that imposed by ceiling construction, as determined from testing per ASTM E 488, calculated loading. Steel Rigid furring Channels: ASTM C 645. Where shown as "Resilient", provide manufacturer's special type designed to reduce sound transmission. Steel Studs for Furring Channels: ASTM C 645. Grid Suspension System: ASTM C 645, manufacturer's standard grid suspension system composed of main beams and cross furring members which interlock to form a modular supporting network. Steel Framing for Walls and Partitions: Comply with ASTM C 754 and the following: Steel Studs find Runners: ASTM C 645, 0.0179 inch base metal thickness unless otherwise indicated. 8776/GYPSUM DRYWALL 09250 - 1 RICKS COLLEGE/ PLANT SCTFN('F REMODEL If f 1naledom .r, ?3itL Itel latlaw c * -7a'S -J66 vrju w: S LTt ,ac:,r*i T. 7 t- d,r, T dxr r' U 0 from construction operations; remove any such substances by method approved by glass manufacturer. Wash glass on both faces not more than 4 days prior to date scheduled for inspections intended to establish date of substantial completion. Wash glass by method recommended by glass manufac- turer. END OF SECTION 08800 8776/GLASS AND GLAZING 08800 - 3 RICKS COLLEGE/ PLANT SCIENCE REMODEL Clear Tempered Float Glass: Kind FT, Condition A, Type I, Class 1, Quality q3. Manufacturing Process: Vertical (tong -held) or horizontal (roller -hearth). Provide heat -treated panes of kind and at locations indicated and as recommended by glass manufacturer for application indicated. Thickness of Each Pane: 1/4". Tempered clear float glass. Glazing Sealant: Comply with sealant and glass manufacturers for selection of glass sealants which suit project application and installation conditions and which are compatible with surfaces contacted. Provide color of exposed sealants indicated or as selected by Architect. C). 2-Part PolVsulfide Glazing Sealant: ASTM C 920, Type M; Grade NS; Class 25; Uses NT, G, A, and, as applicable, 0. Preformed Butyl-PolVisobutylene Glazing Tape: AAMA 804.1, with or without continuous spacer rod as recommended by manufacturers of tape and glass for application indicated. Cleaners, Primers and Sealers: Type recommended by manufacturer of sealants/gaskets. Blocks and Spacers: Neoprene, EPDM or silicone as required for compatibility with glazing sealants; of 80 to 90 Shore A hardness for setting blocks and, for spacers and edge blocks, of hardness recommended by glass and sealant manufacturer for application indicated. Compressible Filler Rods: Closed -cell or waterproof -jacketed rod stock of synthetic rubber or plastic foam, 5-10 psi compression strength for 25 percent compression. Glass Installation (Glazing): General: Comply with referenced FGMA standards and instructions of manufacturers of glass, glazing sealants, and gaskets, to achieve airtight and watertight performance, and to minimize breakage. Protect glass from edge damage during handling and installation. Inspect glass during installation and discard pieces with edge damage that could affect glass performance. 'Set units of glass in each series with uniformity of pattern, draw, bow and similar characteristics. Protect glass from contact with contaminating substances resulting 8776/GLASS AND GLAZING 08800 - RICKS COLLEGE/ PLANT SCIENCE REMODEL SECTION 08800 - GLASS AND GLAZING General• Glazing Standards: Comply with FGMA "Glazing Manual" and "Sealant Manual". Safety Glazing Standard: Comply with ANSI Z97.1 and testing requirements of 16 CFR Part 1201 for category II materials. Fire Resistance Rated Wire Glass: Provide UL-labeled and listed products, identical with those tested per ASTM E 163 (UL 9). Preconstruction Sealant -Substrate Tests: Submit glass and glazing substrate materials to manufacturer of glazing sealants for testing to determine if primers are required and for sealant compatibility. Submittals: In addition to product data submit the following: Samples of each glass indicated, except for clear single pane units; and of each type of sealant or gasket exposed to view. Certificates of compliance from glass and glazing materials manufacturers. Test reports for sealant -substrate adhesion and sealant compatibility. Products: Glass Manufacturer: Subject to compliance with requirements, provide products of one of the following: AFG Industries, Inc Ford Glass Division. Guardian Industries Corp. LOF Glass, Inc. PPG Industries Inc. Sizes: Fabricate glass of thicknesses indicated and to sizes required for glazing openings indicated, with edge clearances and tolerances complying with recommendations of glass manufacturer. Primary Glass Products: Comply with ASTM C 1036 for the following: Clear Float Glass: Type I, Class 1, Quality q3. Polished Wire Glass: Type II, Class 1, Quality q8, Form 1, Complying with ANSI 27197.1; 1/4" thick; of mesh indicated below: Mesh m2 - square. Uncoated Heat -Treated Float Glass Products: Comply with ASTM C 1048 and with manufacturing process indicated for the following: 8776/GLASS AND GLAZING 08800 - 1 RICKS COLLEGE/ PLANT SCIENCE REMODEL mm.-9-lrp 150 South Arthur Suite 207 Pocatello, Idaho 83204 (208) 232-5981 ARCHITECTS/PLANNERS