Loading...
HomeMy WebLinkAboutMANUAL J - 22-00724 - Coates Landscape Supply - Mechanical2022-Aug-25 11:13:00 Rig ht-Su ite® U niv er sal 20 22 22 .0.02 RSU2 8163 Page 1 ...s's\IFPS\Coates Landscape\Coats Landscaping.rup Calc = CLTD Front Door faces: N Coats LandscapineJob:Building Analysis 8/16/2022Date:Entire House Gene MillerBy: Coats LandscapingPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com Project Information Idaho Furnace & Plumbing ServiceFor: Design Conditions Location:CoolingHeatingIndoor: 7570Indoor temp era ture (°F)Idaho Falls Rgnl, ID, US 1477Design TD (°F)ft4744Elevation: 5028Relative humidity (%)°N44Latitude:Outdoor:-29.435.3Moisture difference (gr/lb)CoolingHeating Infiltration:89-7Dry bul b (°F) SimplifiedMethod)H(35-Da ily ra nge (°F) AverageConstruction quality60-We t bu lb (°F) 7.515.0Wind speed (mph) Heating Walls Glazing Doors Ceilings Other Inf iltration Ventilation Humidif ication % of loadBtuhBtuh/ft²Component 10.9118964.4Walls 2.0220923.0Glazing 10.51152525.3Doors 4.144481.6Ceilings 1.819681.01.0Floors 15.51701730.9Infiltration 00Ducts 00Piping 15.516989Humidification 39.643392Ventilation0Adjustments 100.0109443Total Cooling Jul 1800 LDT WallsGlazingOtherCeilings Internal Gains Ventilation % of loadBtuhBtuh/ft²Component 5.543681.6Walls 4.9389040.5Glazing 0.86161.4Doors 4.435171.2Ceilings 000Floors 0.21710.3Infiltration 00Ducts 9.77666Ventilation 74.558945Internal gains 00Blower 0Adjustments 100.079173Total Latent Cooling Load = -7934 Btuh Overall U-va lue = 0.0 52 Btuh/ft²-°F Data entries checked. 2022-Aug-25 11:13:00 Rig ht-Su ite® U niv er sal 20 22 22 .0.02 RSU2 8163 Page 2 ...s's\IFPS\Coates Landscape\Coats Landscaping.rup Calc = CLTD Front Door faces: N Coats LandscapineJob:Building Analysis 8/16/2022Date:Conf.Gene MillerBy: Coats LandscapingPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com Project Information Idaho Furnace & Plumbing ServiceFor: Design Conditions Location:CoolingHeatingIndoor: 7570Indoor temp era ture (°F)Idaho Falls Rgnl, ID, US 1477Design TD (°F)ft4744Elevation: 5028Relative humidity (%)°N44Latitude:Outdoor:-29.435.3Moisture difference (gr/lb)CoolingHeating Infiltration:89-7Dry bul b (°F) SimplifiedMethod)H(35-Da ily ra nge (°F) AverageConstruction quality60-We t bu lb (°F) 7.515.0Wind speed (mph) Heating Walls Doors Ceilings Other Inf iltration Ventilation Humidif ication % of loadBtuhBtuh/ft²Component 9.459204.5Walls 000Glazing 16.71046125.3Doors 6.842491.6Ceilings 0.000.70.7Floors 12.4775918.8Infiltration 00Ducts 00Piping 14.79227Humidification 40.025049Ventilation0Adjustments 100.062664Total Cooling Jul 1800 LDT WallsDoors Ceilings Internal Gains Ventilation % of loadBtuhBtuh/ft²Component 8.019411.5Walls 000Glazing 2.35591.4Doors 15.537481.4Ceilings 000Floors 000Infiltration 00Ducts 19.74768Ventilation 54.613235Internal gains 00Blower 0Adjustments 100.024251Total Latent Cooling Load = -4553 Btuh Overall U-va lue = 0.0 60 Btuh/ft²-°F Data entries checked. 2022-Aug-25 11:13:00 Rig ht-Su ite® U niv er sal 20 22 22 .0.02 RSU2 8163 Page 3 ...s's\IFPS\Coates Landscape\Coats Landscaping.rup Calc = CLTD Front Door faces: N Coats LandscapineJob:Building Analysis 8/16/2022Date:Server MS Gene MillerBy: Coats LandscapingPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com Project Information Idaho Furnace & Plumbing ServiceFor: Design Conditions Location:CoolingHeatingIndoor: 7570Indoor temp era ture (°F)Idaho Falls Rgnl, ID, US 1477Design TD (°F)ft4744Elevation: 5028Relative humidity (%)°N44Latitude:Outdoor:-29.435.3Moisture difference (gr/lb)CoolingHeating Infiltration:89-7Dry bul b (°F) SimplifiedMethod)H(35-Da ily ra nge (°F) AverageConstruction quality60-We t bu lb (°F) 7.515.0Wind speed (mph) Heating Walls Ceilings Floors Inf iltration Humidif ication % of loadBtuhBtuh/ft²Component 19.33183.5Walls 000Glazing 000Doors 12.01991.6Ceilings 5.3870.70.7Floors 49.58170Infiltration 00Ducts 00Piping 13.9230Humidification 00Ventilation0Adjustments 100.01651Total Cooling Jul 1800 LDT Other Internal Gains % of loadBtuhBtuh/ft²Component 0.0-30.0Walls 000Glazing 000Doors 0.91751.4Ceilings 000Floors 0.61040Infiltration 00Ducts 00Ventilation 98.518390Internal gains 00Blower 0Adjustments 100.018666Total Latent Cooling Load = -129 Btuh Overall U-va lue = 0.0 19 Btuh/ft²-°F Data entries checked. 2022-Aug-25 11:13:00 Rig ht-Su ite® U niv er sal 20 22 22 .0.02 RSU2 8163 Page 4 ...s's\IFPS\Coates Landscape\Coats Landscaping.rup Calc = CLTD Front Door faces: N Coats LandscapineJob:Building Analysis 8/16/2022Date:Show Rm AH Gene MillerBy: Coats LandscapingPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com Project Information Idaho Furnace & Plumbing ServiceFor: Design Conditions Location:CoolingHeatingIndoor: 7570Indoor temp era ture (°F)Idaho Falls Rgnl, ID, US 1477Design TD (°F)ft4744Elevation: 5028Relative humidity (%)°N44Latitude:Outdoor:-29.435.3Moisture difference (gr/lb)CoolingHeating Infiltration:89-7Dry bul b (°F) SimplifiedMethod)H(35-Da ily ra nge (°F) AverageConstruction quality60-We t bu lb (°F) 7.515.0Wind speed (mph) Heating Walls Glazing Doors Floors Inf iltration Ventilation Humidif ication % of loadBtuhBtuh/ft²Component 12.556584.5Walls 4.9220923.0Glazing 2.4106425.3Doors 000Ceilings 4.218801.11.1Floors 18.7844161.2Infiltration 00Ducts 00Piping 16.77533Humidification 40.618343Ventilation0Adjustments 100.045128Total Cooling Jul 1800 LDT Walls Glazing Other Internal Gains Ventilation % of loadBtuhBtuh/ft²Component 6.222891.8Walls 10.5389040.5Glazing 0.2571.4Doors 000Ceilings 000Floors 0.2750.5Infiltration 00Ducts 8.83241Ventilation 74.127320Internal gains 00Blower 0Adjustments 100.036871Total Latent Cooling Load = -3252 Btuh Overall U-va lue = 0.0 44 Btuh/ft²-°F Data entries checked. 2022-Aug-25 11:13:01 Rig ht-Su ite® U niv er sal 20 22 22 .0.02 RSU2 8163 Page 1 ...s's\IFPS\Coates Landscape\Coats Landscaping.rup Calc = CLTD Front Door faces: N Coats LandscapineJob:Component Constructions 8/16/2022Date:Entire House Gene MillerBy: Coats LandscapingPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com Project Information Idaho Furnace & Plumbing ServiceFor: Design Conditions ClgHtgClgHtg 7570Inside db (°F)89-7Outside db (°F) 5028Inside RH (%)2080Outside RH (%) 6251Inside wb (°F)6020Outside wb (°F) 1477Design TD (°F)35-Da ily ra nge (°F) -2935.3Moisture diff. (gr/lb) Construction descriptions GainLossUAU-valueAreaOr (Btuh)(Btuh)(Btuh/°F)(Btuh/ft²-°F )ft² Walls Bg wall, light dry soil, 2"x4" wood int frm, concrete wall, r-19 cav ins, 8" thk, 1/2" gypsum board int fnsh -33182.90.0392n Frm wall, mtl ext, 3/8" wood shth, r-21 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 349267134.80.06597n 844415.80.0699e 1009340444.40.06760s 2739455959.40.061018w 1032723.60.0661nw 872303.00.0651nw 4371115781510.062585all Partitions (none) Windows clghtgclghtg 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/8" thk; NFRC rated (SHGC=0.35); foreground = new concrete (0.32); 6.67 ft head ht 4095527.2/7.20.30/0.3024n 3481165721.6/21.60.30/0.3072w 3890220928.8/28.80.30/0.3096all Doors Door, wd sc type 4379810.40.3332n 51796631260.33382e 57106413.90.3342nw 616115251500.33455all Ceilings Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 1/2" gypsum board int fnsh 3517444858.00.022865 Floors Bg floor, light dry soil, 6.5' depth, vinyl flr fnsh 0.01129 0871.1 Bg floor, light dry soil, on grade depth, r-10 edge ins, vinyl flr fnsh 188024.50.21117 0 2022-Aug-25 11:13:01 Rig ht-Su ite® U niv er sal 20 22 22 .0.02 RSU2 8163 Page 2 ...s's\IFPS\Coates Landscape\Coats Landscaping.rup Calc = CLTD Front Door faces: N Coats LandscapineJob:Component Constructions 8/16/2022Date:Server MS Gene MillerBy: Coats LandscapingPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com Project Information Idaho Furnace & Plumbing ServiceFor: Design Conditions ClgHtgClgHtg 7570Inside db (°F)89-7Outside db (°F) 5028Inside RH (%)2080Outside RH (%) 6251Inside wb (°F)6020Outside wb (°F) 1477Design TD (°F)35-Da ily ra nge (°F) -2935.3Moisture diff. (gr/lb) Construction descriptions GainLossUAU-valueAreaOr (Btuh)(Btuh)(Btuh/°F)(Btuh/ft²-°F )ft² Walls Bg wall, light dry soil, 2"x4" wood int frm, concrete wall, r-19 cav ins, 8" thk, 1/2" gypsum board int fnsh -33182.90.0392n Partitions (none) Windows clghtgclghtg (none) Doors (none) Ceilings Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 1/2" gypsum board int fnsh 1751992.60.02128 Floors Bg floor, light dry soil, 6.5' depth, vinyl flr fnsh 0.01128 0871.1 2022-Aug-25 11:13:01 Rig ht-Su ite® U niv er sal 20 22 22 .0.02 RSU2 8163 Page 3 ...s's\IFPS\Coates Landscape\Coats Landscaping.rup Calc = CLTD Front Door faces: N Coats LandscapineJob:Component Constructions 8/16/2022Date:Conf.Gene MillerBy: Coats LandscapingPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com Project Information Idaho Furnace & Plumbing ServiceFor: Design Conditions ClgHtgClgHtg 7570Inside db (°F)89-7Outside db (°F) 5028Inside RH (%)2080Outside RH (%) 6251Inside wb (°F)6020Outside wb (°F) 1477Design TD (°F)35-Da ily ra nge (°F) -2935.3Moisture diff. (gr/lb) Construction descriptions GainLossUAU-valueAreaOr (Btuh)(Btuh)(Btuh/°F)(Btuh/ft²-°F )ft² Walls Frm wall, mtl ext, 3/8" wood shth, r-21 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 191146219.10.06327n 884415.80.0699e 647179123.40.06400s 941195325.50.06436w 742723.60.0661nw 1941592077.20.061322all Partitions (none) Windows clghtgclghtg (none) Doors Door, wd sc type 4379810.40.3332n 51796631260.33382e 559104611360.33413all Ceilings Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 1/2" gypsum board int fnsh 3748424955.40.022737 Floors Bg floor, light dry soil, 6.5' depth, vinyl flr fnsh 0.011 000.0 2022-Aug-25 11:13:01 Rig ht-Su ite® U niv er sal 20 22 22 .0.02 RSU2 8163 Page 4 ...s's\IFPS\Coates Landscape\Coats Landscaping.rup Calc = CLTD Front Door faces: N Coats LandscapineJob:Component Constructions 8/16/2022Date:Show Rm AH Gene MillerBy: Coats LandscapingPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com Project Information Idaho Furnace & Plumbing ServiceFor: Design Conditions ClgHtgClgHtg 7570Inside db (°F)89-7Outside db (°F) 5028Inside RH (%)2080Outside RH (%) 6251Inside wb (°F)6020Outside wb (°F) 1477Design TD (°F)35-Da ily ra nge (°F) -2935.3Moisture diff. (gr/lb) Construction descriptions GainLossUAU-valueAreaOr (Btuh)(Btuh)(Btuh/°F)(Btuh/ft²-°F )ft² Walls Frm wall, mtl ext, 3/8" wood shth, r-21 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 158120915.80.06270n 478161221.00.06360s 1566260634.00.06582w 872303.00.0651nw 2289565873.80.061263all Partitions (none) Windows clghtgclghtg 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/8" thk; NFRC rated (SHGC=0.35); foreground = new concrete (0.32); 6.67 ft head ht 4095527.2/7.20.30/0.3024n 3481165721.6/21.60.30/0.3072w 3890220928.8/28.80.30/0.3096all Doors Door, wd sc type 57106413.90.3342nw Ceilings (none) Floors Bg floor, light dry soil, on grade depth, r-10 edge ins, vinyl flr fnsh 188024.50.21117 0 2022-Aug-25 11:13:01 Rig ht-Su ite® U niv er sal 20 22 22 .0.02 RSU2 8163 Page 1 ...s's\IFPS\Coates Landscape\Coats Landscaping.rup Calc = CLTD Front Door faces: N ASHRAE/ACCA COMPLIANCE FORM FOR STANDARD 183 Building or Zone Name: Entire House Location or Address: Design Conditions: HeatingCooling Idaho Falls Rgnl, ID, USWeather Data Used °F70°F75Indoor Dry Bulb Design Temperature %28%50Indoor Design Relative Humidity Load Calculation Method: (Indicate which of the following methods is used.) — Coo ling Load Tem pra tture Diff eren ce / C ool ing L oad Fac tor m etho dsCLTD/CLF — Hea t Bal ance m e thod sHB — Tota l Eq uival ent T em p erat ure D iffe renc e / Ti m e Avera ging m e thod sTETD/TA — Tran s fer Fun ction m e thod sTFM — Rad iant Tim e Ser ies m eth odsRTS (please specify)OTHER The undersigned attests that the above information is correct and that the procedures used to perform the load calculations comply with ANSI/ASHRAE/ACCA Standard 183 Date:Signed: Date:Submitted by: 8/16/2022Gene Miller 2022-Aug-25 11:13:01 Rig ht-Su ite® U niv er sal 20 22 22 .0.02 RSU2 8163 Page 1 ...s's\IFPS\Coates Landscape\Coats Landscaping.rup Calc = CLTD Front Door faces: N Coats LandscapineJob:Right -Suite® Unive rsal 2022 Sce nar io 8/16/2022Date:Automotive Facility - Retail Gene MillerBy: Coats LandscapingPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com Cooling set point schedule:Clg75 Cooling inside relative humidity:%50 Heating set point:°F70 People Sensible Latent Activity ft²/prsn #Btuh/prsn Btuh/prsn Schedule Garage 15200 565 1035 8ato8p Lights Space fractFactorWW/ft²Lamp/blst + fixture Schedule 1.001.2001.31Fluor MB + Rec trof 8ato8p Appliances / Plug Loads Sensible Latent Application Usage (Btuh)(Btuh)Schedule Motors Power Load Sensible (hp)#/ft²#factor (Btuh)Schedule 2022-Aug-25 11:13:01 Rig ht-Su ite® U niv er sal 20 22 22 .0.02 RSU2 8163 Page 2 ...s's\IFPS\Coates Landscape\Coats Landscaping.rup Calc = CLTD Front Door faces: N Coats LandscapineJob:Right -Suite® Unive rsal 2022 Sce nar io 8/16/2022Date:Workshop - Default Workshop conditions Gene MillerBy: Coats LandscapingPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com Cooling set point schedule:Clg75 Cooling inside relative humidity:%50 Heating set point:°F70 People Sensible Latent Activity ft²/prsn #Btuh/prsn Btuh/prsn Schedule Factory 0300 375 625 8to6-E Lights Space fractFactorWW/ft²Lamp/blst + fixture Schedule 1.001.2002.83Fluor MB + Rec trof 8to6-E Appliances / Plug Loads Sensible Latent Application Usage (Btuh)(Btuh)Schedule Motors Power Load Sensible (hp)#/ft²#factor (Btuh)Schedule 2022-Aug-25 11:13:01 Rig ht-Su ite® U niv er sal 20 22 22 .0.02 RSU2 8163 Page 1 ...s's\IFPS\Coates Landscape\Coats Landscaping.rup Calc = CLTD Front Door faces: N Coats LandscapineJob:Righ t-Suite® Univ er sal 20 22 Sh or t F or m 8/16/2022Date:Entire House Gene MillerBy: Coats LandscapingPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com Project Information Idaho Furnace & Plumbing ServiceFor: Htg Clg Htg Clg Outside db 89-7(°F)Inside db 7570(°F) Outside RH 20-(%)Inside RH 50-(%) Outside wb 60-(°F)Inside wb 62-(°F) Daily range 35-(°F)Design TD 1477(°F) Moisture diff.-29-(gr/lb) Cooling EquipmentHeating Equipment Make n/a Make n/a Model n/a Model n/a Type n/a Type n/a Efficiency n/a COP / EER / SEER 0 Heating Input MBtuh0 Sensible Cooling MBtuh0 Heating Output MBtuh0 Latent Cooling MBtuh0 Humidifier gpd0 Total Cooling MBtuh0 Leaving Air Temp °F0 Leaving Air Temp °F0 Actual Heating Fan cfm0 Actual Cooling Fan cfm0 Equipment Location Entire House System Type n/a Fan Motor Heat Type n/a Fan & Motor Combined Efficiency %0 Static Pressure Across Fan in H2O0 NAME Area Heat Sensible Latent Htg Clg Time ft²Loss Gain Gain cfm cfm Conf.2737 Jul 1800 LDT18001688-45532366162664 Server MS 128 Jul 1800 LDT760760-129186401651 Show Rm AH 1785 Jul 1800 LDT18001688-32523687145128 Entire House 4650 109443 79173 -7934 4136 4360 Jul 1800 LDT 2022-Aug-25 11:13:01 Rig ht-Su ite® U niv er sal 20 22 22 .0.02 RSU2 8163 Page 2 ...s's\IFPS\Coates Landscape\Coats Landscaping.rup Calc = CLTD Front Door faces: N Coats LandscapineJob:Righ t-Suite® Univ er sal 20 22 Sh or t F or m 8/16/2022Date:Conf.Gene MillerBy: Coats LandscapingPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com Project Information Idaho Furnace & Plumbing ServiceFor: Htg Clg Htg Clg Outside db 89-7(°F)Inside db 7570(°F) Outside RH 20-(%)Inside RH 50-(%) Outside wb 60-(°F)Inside wb 62-(°F) Daily range 35-(°F)Design TD 1477(°F) Moisture diff.-29-(gr/lb) Cooling EquipmentHeating Equipment Make Generic Make Ammana Model SEER14-036G Model APU14M61080 Type Pkg gas furnace Type Pkg AC Efficiency 87 AFUE COP / EER / SEER 14.0 Heating Input MBtuh80.0 Sensible Cooling MBtuh51.6 Heating Output MBtuh64.0 Latent Cooling MBtuh0 Humidifier gpd24.8 Total Cooling MBtuh51.6 Leaving Air Temp °F111.0 Leaving Air Temp °F55.0 Actual Heating Fan cfm1688 Actual Cooling Fan cfm1800 Equipment Location Conf. System Type PEAKCV Fan Motor Heat Type PACKAGE Fan & Motor Combined Efficiency %0 Static Pressure Across Fan in H2O0 NAME Area Heat Sensible Latent Htg Clg Time ft²Loss Gain Gain cfm cfm Conference Rm 2737 Jul 1800 LDT18001688-45532366162664 Conf.2737 62664 23661 -4553 1688 1800 Jul 1800 LDT 2022-Aug-25 11:13:01 Rig ht-Su ite® U niv er sal 20 22 22 .0.02 RSU2 8163 Page 3 ...s's\IFPS\Coates Landscape\Coats Landscaping.rup Calc = CLTD Front Door faces: N Coats LandscapineJob:Righ t-Suite® Univ er sal 20 22 Sh or t F or m 8/16/2022Date:Server MS Gene MillerBy: Coats LandscapingPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com Project Information Idaho Furnace & Plumbing ServiceFor: Htg Clg Htg Clg Outside db 89-7(°F)Inside db 7570(°F) Outside RH 20-(%)Inside RH 50-(%) Outside wb 60-(°F)Inside wb 62-(°F) Daily range 35-(°F)Design TD 1477(°F) Moisture diff.-29-(gr/lb) Cooling EquipmentHeating Equipment Make n/a Make Fujitsu Model n/a Model FO2416CSJ Type n/a Type Split AC Efficiency n/a COP / EER / SEER 14.0 Heating Input MBtuh0 Sensible Cooling MBtuh21.4 Heating Output MBtuh0 Latent Cooling MBtuh0 Humidifier gpd0.6 Total Cooling MBtuh21.4 Leaving Air Temp °F70.0 Leaving Air Temp °F55.0 Actual Heating Fan cfm760 Actual Cooling Fan cfm760 Equipment Location Server MS System Type PEAKCV Fan Motor Heat Type PACKAGE Fan & Motor Combined Efficiency %0 Static Pressure Across Fan in H2O0 NAME Area Heat Sensible Latent Htg Clg Time ft²Loss Gain Gain cfm cfm Server RM 128 Jul 1800 LDT760760-129186401651 Server MS 128 1651 18640 -129 760 760 Jul 1800 LDT 2022-Aug-25 11:13:01 Rig ht-Su ite® U niv er sal 20 22 22 .0.02 RSU2 8163 Page 4 ...s's\IFPS\Coates Landscape\Coats Landscaping.rup Calc = CLTD Front Door faces: N Coats LandscapineJob:Righ t-Suite® Univ er sal 20 22 Sh or t F or m 8/16/2022Date:Show Rm AH Gene MillerBy: Coats LandscapingPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com Project Information Idaho Furnace & Plumbing ServiceFor: Htg Clg Htg Clg Outside db 89-7(°F)Inside db 7570(°F) Outside RH 20-(%)Inside RH 50-(%) Outside wb 60-(°F)Inside wb 62-(°F) Daily range 35-(°F)Design TD 1477(°F) Moisture diff.-29-(gr/lb) Cooling EquipmentHeating Equipment Make Generic Make Ammana Model SEER-9-054G Model APU14M61080 Type Pkg gas furnace Type Pkg AC Efficiency 78 AFUE COP / EER / SEER 9.0 Heating Input MBtuh80.0 Sensible Cooling MBtuh51.6 Heating Output MBtuh64.0 Latent Cooling MBtuh0 Humidifier gpd20.3 Total Cooling MBtuh51.6 Leaving Air Temp °F111.0 Leaving Air Temp °F55.0 Actual Heating Fan cfm1688 Actual Cooling Fan cfm1800 Equipment Location Show Rm AH System Type PEAKCV Fan Motor Heat Type PACKAGE Fan & Motor Combined Efficiency %0 Static Pressure Across Fan in H2O0 NAME Area Heat Sensible Latent Htg Clg Time ft²Loss Gain Gain cfm cfm Show Rm 1785 Jul 1800 LDT18001688-32523687145128 Show Rm AH 1785 45128 36871 -3252 1688 1800 Jul 1800 LDT 2022-Aug-25 11:13:01 Rig ht-Su ite® U niv er sal 20 22 22 .0.02 RSU2 8163 Page 1 ...s's\IFPS\Coates Landscape\Coats Landscaping.rup Calc = CLTD Front Door faces: N Coats LandscapineJob:Right -Suite® Unive rsal 2022 Load Summary 8/16/2022Date:Entire House Gene MillerBy: Coats LandscapingPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com Project Information Idaho Furnace & Plumbing ServiceFor: COOLING LOADEntire HouseZone: Peak load at Jul 1800 LDTat Jul 1800 LDT1. DESIGN CONDITIONS Inside:°F75 Outside:°F89 TD:°F14 RH:20 %MoistDiff:gr/lb-29 Mult:1.0 Ins.wb °F62 Sensible Latent 37722. SOLAR RADIATION THROUGH GLASS - 3. TRANSMISSION GAINS Sensible 8619 - Walls:4368 -- Glass:118 -- Doors:616 -- Partitions:0 -- Floors:0 -- Ceilings:3517 -- 4. INTERNAL HEAT GAIN Sensible Latent 256558945 Occupants:25652862 -- Lights:26354 --- Motors:0 --- Appliances:029729 -- 5. INFILTRATION:14Outside air cfm:171 -230 6. SUBTOTAL:Space load Sensible Latent 233571507 Envelope 233571507 -- Less external 0 --- Redistribution 00 -- 07. SUPPLY DUCT - 8. SUBTOTAL:Space load + supply duct 71507 - 4360Actual cfm:at supply TD:20 -- Make-up air cfm:9. VENTILATION:7666612 -10269 10. RETURN AIR LOAD:Lighting + plenum (net)0 - 011. RETURN DUCT - -79347917312. TOTAL LOADS ON EQUIPMENT HEATING LOAD 13. DESIGN CONDITIONS Mult:1.0 Inside:°F70 Outside:°F-7 TD:°F77 14. TRANSMISSION LOSSES 32045 Walls:11896 - Glass:2209 - Doors:11525 - Partitions:0 - Floors:1968 - Ceilings:4448 - 15. INFILTRATION:17017240Outside air cfm: 16. SUBTOTAL:Space load 49062 Envelope 49062 - Less external 0 - Less transfer 0 - Redistribution 0 - 17. SUPPLY DUCT:0 18. VENTILATION:43392612Make-up air cfm: 19. HUMIDIFICATION 16989 Piping 0 20. RETURN DUCT 0 21. TOTAL HEATING LOAD ON EQUIPMENT 109443 2022-Aug-25 11:13:01 Rig ht-Su ite® U niv er sal 20 22 22 .0.02 RSU2 8163 Page 2 ...s's\IFPS\Coates Landscape\Coats Landscaping.rup Calc = CLTD Front Door faces: N Coats LandscapineJob:Right -Suite® Unive rsal 2022 Load Summary 8/16/2022Date:Conf.Gene MillerBy: Coats LandscapingPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com Project Information Idaho Furnace & Plumbing ServiceFor: COOLING LOADConf.Zone: Peak load at Jul 1700 LDTat Jul 1800 LDT1. DESIGN CONDITIONS Inside:°F75 Outside:°F89 TD:°F14 RH:20 %MoistDiff:gr/lb-29 Mult:1.0 Ins.wb °F62 Sensible Latent 02. SOLAR RADIATION THROUGH GLASS - 3. TRANSMISSION GAINS Sensible 6001 - Walls:2082 -- Glass:0 -- Doors:559 -- Partitions:0 -- Floors:0 -- Ceilings:3360 -- 4. INTERNAL HEAT GAIN Sensible Latent 137513235 Occupants:13751375 -- Lights:355 --- Motors:0 --- Appliances:011505 -- 5. INFILTRATION:0Outside air cfm:0 0 6. SUBTOTAL:Space load Sensible Latent 137519236 Envelope 137519236 -- Less external 0 --- Redistribution 00 -- 07. SUPPLY DUCT - 8. SUBTOTAL:Space load + supply duct 19236 - 1800Actual cfm:at supply TD:20 -- Make-up air cfm:9. VENTILATION:4425353 -5928 10. RETURN AIR LOAD:Lighting + plenum (net)0 - 011. RETURN DUCT - -45532366112. TOTAL LOADS ON EQUIPMENT HEATING LOAD 13. DESIGN CONDITIONS Mult:1.0 Inside:°F70 Outside:°F-7 TD:°F77 14. TRANSMISSION LOSSES 20630 Walls:5920 - Glass:0 - Doors:10461 - Partitions:0 - Floors:0 - Ceilings:4249 - 15. INFILTRATION:7759109Outside air cfm: 16. SUBTOTAL:Space load 28389 Envelope 28389 - Less external 0 - Less transfer 0 - Redistribution 0 - 17. SUPPLY DUCT:0 18. VENTILATION:25049353Make-up air cfm: 19. HUMIDIFICATION 9227 Piping 0 20. RETURN DUCT 0 21. TOTAL HEATING LOAD ON EQUIPMENT 62664 2022-Aug-25 11:13:01 Rig ht-Su ite® U niv er sal 20 22 22 .0.02 RSU2 8163 Page 3 ...s's\IFPS\Coates Landscape\Coats Landscaping.rup Calc = CLTD Front Door faces: N Coats LandscapineJob:Right -Suite® Unive rsal 2022 Load Summary 8/16/2022Date:Server MS Gene MillerBy: Coats LandscapingPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com Project Information Idaho Furnace & Plumbing ServiceFor: COOLING LOADServer MSZone: Peak load at Jul 1700 LDTat Jul 1800 LDT1. DESIGN CONDITIONS Inside:°F75 Outside:°F89 TD:°F14 RH:20 %MoistDiff:gr/lb-29 Mult:1.0 Ins.wb °F62 Sensible Latent 02. SOLAR RADIATION THROUGH GLASS - 3. TRANSMISSION GAINS Sensible 154 - Walls:-3 -- Glass:0 -- Doors:0 -- Partitions:0 -- Floors:0 -- Ceilings:157 -- 4. INTERNAL HEAT GAIN Sensible Latent 018390 Occupants:00 -- Lights:166 --- Motors:0 --- Appliances:018224 -- 5. INFILTRATION:8Outside air cfm:96 -129 6. SUBTOTAL:Space load Sensible Latent -12918640 Envelope -12918640 -- Less external 0 --- Redistribution 00 -- 07. SUPPLY DUCT - 8. SUBTOTAL:Space load + supply duct 18640 - 760Actual cfm:at supply TD:20 -- Make-up air cfm:9. VENTILATION:00 0 10. RETURN AIR LOAD:Lighting + plenum (net)0 - 011. RETURN DUCT - -1291864012. TOTAL LOADS ON EQUIPMENT HEATING LOAD 13. DESIGN CONDITIONS Mult:1.0 Inside:°F70 Outside:°F-7 TD:°F77 14. TRANSMISSION LOSSES 604 Walls:318 - Glass:0 - Doors:0 - Partitions:0 - Floors:87 - Ceilings:199 - 15. INFILTRATION:81712Outside air cfm: 16. SUBTOTAL:Space load 1421 Envelope 1421 - Less external 0 - Less transfer 0 - Redistribution 0 - 17. SUPPLY DUCT:0 18. VENTILATION:00Make-up air cfm: 19. HUMIDIFICATION 230 Piping 0 20. RETURN DUCT 0 21. TOTAL HEATING LOAD ON EQUIPMENT 1651 2022-Aug-25 11:13:01 Rig ht-Su ite® U niv er sal 20 22 22 .0.02 RSU2 8163 Page 4 ...s's\IFPS\Coates Landscape\Coats Landscaping.rup Calc = CLTD Front Door faces: N Coats LandscapineJob:Right -Suite® Unive rsal 2022 Load Summary 8/16/2022Date:Show Rm AH Gene MillerBy: Coats LandscapingPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com Project Information Idaho Furnace & Plumbing ServiceFor: COOLING LOADShow Rm AHZone: Peak load at Jul 1800 LDTat Jul 1800 LDT1. DESIGN CONDITIONS Inside:°F75 Outside:°F89 TD:°F14 RH:20 %MoistDiff:gr/lb-29 Mult:1.0 Ins.wb °F62 Sensible Latent 37722. SOLAR RADIATION THROUGH GLASS - 3. TRANSMISSION GAINS Sensible 2464 - Walls:2289 -- Glass:118 -- Doors:57 -- Partitions:0 -- Floors:0 -- Ceilings:0 -- 4. INTERNAL HEAT GAIN Sensible Latent 119027320 Occupants:11901487 -- Lights:25832 --- Motors:0 --- Appliances:00 -- 5. INFILTRATION:6Outside air cfm:75 -101 6. SUBTOTAL:Space load Sensible Latent 108933630 Envelope 108933630 -- Less external 0 --- Redistribution 00 -- 07. SUPPLY DUCT - 8. SUBTOTAL:Space load + supply duct 33630 - 1800Actual cfm:at supply TD:20 -- Make-up air cfm:9. VENTILATION:3241259 -4341 10. RETURN AIR LOAD:Lighting + plenum (net)0 - 011. RETURN DUCT - -32523687112. TOTAL LOADS ON EQUIPMENT HEATING LOAD 13. DESIGN CONDITIONS Mult:1.0 Inside:°F70 Outside:°F-7 TD:°F77 14. TRANSMISSION LOSSES 10811 Walls:5658 - Glass:2209 - Doors:1064 - Partitions:0 - Floors:1880 - Ceilings:0 - 15. INFILTRATION:8441119Outside air cfm: 16. SUBTOTAL:Space load 19252 Envelope 19252 - Less external 0 - Less transfer 0 - Redistribution 0 - 17. SUPPLY DUCT:0 18. VENTILATION:18343259Make-up air cfm: 19. HUMIDIFICATION 7533 Piping 0 20. RETURN DUCT 0 21. TOTAL HEATING LOAD ON EQUIPMENT 45128 Job #: Coats Landscapine Performed by Gene Miller for: Idaho Furnace & Plumbing Service Mechanical Compliance Solutions 4181 Aschli lane Idaho Falls, ID 83406 Phone: 208-881-3243 gene.mechcompliancesolutions@gmail.com Scale: 1 : 195 Page 1 Ri gh t-Sui te® Uni versal 2022 22.0.02 RSU28163 2022-Aug-25 11:13:51 ... Landscape\Coats Landscaping.rup N Main Floor Boiler Rm Shop Area Unloading area Reciving Restroom Office 2Office 1 Show Rm Server RM FRESH AIR WILL BE SUPPLIED WITH A PIPE AND DAMPER 200 cfm 200 cfm 200 cfm 200 cfm 200 cfm 200 cfm 200 cfm 200 cfm 200 cfm 760 cfm760 cfm 1800 cfm 32 x 12 8-14x3.25 30 x 10 8 " 8 " 8 " 8 " 8 " 8 " 8 " 8 "8 " Ret Riser 32 x 12 30 x 10 Sup Riser30 x 10 32 x 12 24 x 10 18 x 10 Job #: Coats Landscapine Performed by Gene Miller for: Idaho Furnace & Plumbing Service Mechanical Compliance Solutions 4181 Aschli lane Idaho Falls, ID 83406 Phone: 208-881-3243 gene.mechcompliancesolutions@gmail.com Scale: 1 : 195 Page 2 Ri gh t-Sui te® Uni versal 2022 22.0.02 RSU28163 2022-Aug-25 11:13:51 ... Landscape\Coats Landscaping.rup N Mezzanine Conference Rm 225 cfm 225 cfm 225 cfm 225 cfm 225 cfm 225 cfm 1800 cfm 225 cfm Ret Riser 32 x 12 10 " 10 " 30 x 10 Sup Riser 30 x 10 32 x 12 22 " 10 " 10 " 10 " 10 " 225 cfm 10 " 8 " 24 x 8 16 x 8 2022-Aug-25 11:13:01 Rig ht-Su ite® U niv er sal 20 22 22 .0.02 RSU2 8163 Page 1 ...s's\IFPS\Coates Landscape\Coats Landscaping.rup Calc = CLTD Front Door faces: N Coats LandscapineJob:Duct System Summary 8/16/2022Date:Conf.Gene MillerBy: Coats LandscapingPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com Project Information Idaho Furnace & Plumbing ServiceFor: CoolingHeating External static pressure in H2O0.60in H2O0.60 Pressure losses in H2O0in H2O0 Available static pressure in H2O0.60in H2O0.60 Supply / return available pressure 0.341 / 0.259 in H2O in H2O0.341 / 0.259 Lowest friction rate in/100ft0.116in/100ft0.116 Actual air flow cfm1800cfm1688 Total effective length (TEL)ft519 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm)(cfm)FR (in)(in)Matl Ln (ft)Ln (ft)Trunk st2A190.037.5VlFx0x010.00.1502252112435cConference Rm-A st2170.013.5VlFx0x08.00.1862252112435cConference Rm-B st2A200.091.0VlFx0x010.00.1172252112435cConference Rm-C st2180.069.0VlFx0x010.00.1372252112435cConference Rm-D st2B210.084.8VlFx0x010.00.1162252112435cConference Rm-E st2B220.061.3VlFx0x010.00.1212252112435cConference Rm-F st2190.034.0VlFx0x010.00.1522252112435cConference Rm-G st2B230.064.8VlFx0x010.00.1162252112435cConference Rm-H Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st2 Peak AVF 1688 1800 0.116 864 16.7 30x10 ShtMetl st2A Peak AVF 1055 1125 0.116 844 14.0 24x8 ShtMetl st2 st2B Peak AVF 633 675 0.116 759 11.5 16x8 ShtMetl st2A Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in)(cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in)Matl Trunk rb1 0x 16880 1800 224.3 0.116 682 22.0 x0 0 VlFx rt2 2022-Aug-25 11:13:01 Rig ht-Su ite® U niv er sal 20 22 22 .0.02 RSU2 8163 Page 2 ...s's\IFPS\Coates Landscape\Coats Landscaping.rup Calc = CLTD Front Door faces: N Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk rt2 Peak AVF 1688 1800 0.116 675 16.7 32x12 ShtMetl 2022-Aug-25 11:13:01 Rig ht-Su ite® U niv er sal 20 22 22 .0.02 RSU2 8163 Page 3 ...s's\IFPS\Coates Landscape\Coats Landscaping.rup Calc = CLTD Front Door faces: N Coats LandscapineJob:Duct System Summary 8/16/2022Date:Server MS Gene MillerBy: Coats LandscapingPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com Project Information Idaho Furnace & Plumbing ServiceFor: CoolingHeating External static pressure in H2O0.60in H2O0.60 Pressure losses in H2O0.41in H2O0.41 Available static pressure in H2O0.19in H2O0.19 Supply / return available pressure 0.095 / 0.095 in H2O in H2O0.095 / 0.095 Lowest friction rate in/100ft0in/100ft0 Actual air flow cfm760cfm760 Total effective length (TEL)ft0 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm)(cfm)FR (in)(in)Matl Ln (ft)Ln (ft)Trunk 00ShMt0x00076076018666cServer RM-G Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in)(cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in)Matl Trunk rb2 0x 7600 760 0 0 2405 0 3.25x14 10x9 SJSp 2022-Aug-25 11:13:01 Rig ht-Su ite® U niv er sal 20 22 22 .0.02 RSU2 8163 Page 4 ...s's\IFPS\Coates Landscape\Coats Landscaping.rup Calc = CLTD Front Door faces: N Coats LandscapineJob:Duct System Summary 8/16/2022Date:Show Rm AH Gene MillerBy: Coats LandscapingPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com Project Information Idaho Furnace & Plumbing ServiceFor: CoolingHeating External static pressure in H2O0.60in H2O0.60 Pressure losses in H2O0in H2O0 Available static pressure in H2O0.60in H2O0.60 Supply / return available pressure 0.316 / 0.284 in H2O in H2O0.316 / 0.284 Lowest friction rate in/100ft0.099in/100ft0.099 Actual air flow cfm1800cfm1688 Total effective length (TEL)ft608 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm)(cfm)FR (in)(in)Matl Ln (ft)Ln (ft)Trunk st1A180.088.5ShMt0x08.00.1182001883737cShow Rm st1B225.095.8ShMt0x08.00.0992001883737cShow Rm-A st1B210.082.5ShMt0x08.00.1082001883737cShow Rm-B st1B200.070.5ShMt0x08.00.1172001883737cShow Rm-C st1B190.054.8ShMt0x08.00.1292001883737cShow Rm-D st1A170.043.8ShMt0x08.00.1482001883737cShow Rm-E st1150.029.3ShMt0x08.00.1772001883737cShow Rm-F st1160.076.0ShMt0x08.00.1342001883737cShow Rm-G st1B220.088.8ShMt0x08.00.1022001883737cShow Rm-H Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st1B Peak AVF 938 1000 0.099 800 13.8 18x10 ShtMetl st1A st1A Peak AVF 1313 1400 0.099 840 15.7 24x10 ShtMetl st1 st1 Peak AVF 1688 1800 0.099 864 17.2 30x10 ShtMetl 2022-Aug-25 11:13:01 Rig ht-Su ite® U niv er sal 20 22 22 .0.02 RSU2 8163 Page 5 ...s's\IFPS\Coates Landscape\Coats Landscaping.rup Calc = CLTD Front Door faces: N Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in)(cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in)Matl Trunk rb3 0x 16880 1800 287.5 0.099 712 17.2 8-3.25x14 8-10x73 SJSp rt1 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk rt1 Peak AVF 1688 1800 0.099 675 17.2 32x12 ShtMetl