HomeMy WebLinkAboutAPPROVED PLANS - 21-00628 - 1105 Larch Dr - New SFRAuthor Name Author Email Author Phone No.:
Larry Beesley Larry.Beesley@rexburg.org 208-372-2176
Description : 1105 Larch Dr - New SFR
Address :
Record Type : New Single Family Residence
Document Filename : 29649-meadow grove-set-2x6.pdf
Comment Author Contact Information:
Corrections in the following table need to be applied before a permit can be issued
Review Report
Approved
# 21-00628
Page Reference Annotation
Type
Author : Department Status Page Review Comments Applicant Response Comments
Pg 1 Stamp Larry Beesley : Building Open 1 Approved - Building Inspector
Pg 2 Free text Larry Beesley : Building Open 2 Street Number
Displayed on House
Pg 2 Free text Larry Beesley : Building Open 2 Roof Ventilation as per R806
Pg 2 Free text Larry Beesley : Building Open 2 Roof Trusses (designed according to R802.10.1) 35 # Snow and
90 mph winds (Local Conditions)
Pg 2 Free text Larry Beesley : Building Open 2 Minimum Frost Depth Ground Surface to Bottom of Footing
36"
Pg 2 Free text Larry Beesley : Building Open 2 Ground Surface to Slope away from Foundation a minimum of
6" within first 10 ft.
Pg 2 Free text Larry Beesley : Building Open 2 |There is no basement, only a crawl space
Pg 2 Stamp Larry Beesley : Building Open 2 Approved - Building Inspector
Pg 3 Free text Larry Beesley : Building Open 3 Minimum Frost Depth Ground Surface to Bottom of Footing
36"
Pg 3 Free text Larry Beesley : Building Open 3 Ground Surface to Slope away from Foundation a minimum of
6" within first 10 ft.
New Single Family Residence
Approval of plans does not constitute approval of variance from code
Page Reference Annotation
Type
Author : Department Status Page Review Comments Applicant Response Comments
Pg 3 Free text Larry Beesley : Building Open 3 Roof Ventilation as per R806
Pg 3 Free text Larry Beesley : Building Open 3 Roof Trusses (designed according to R802.10.1) 35 # Snow and
90 mph winds (Local Conditions)
Pg 3 Stamp Larry Beesley : Building Open 3 Approved - Building Inspector
Pg 4 Free text Larry Beesley : Building Open 4 x
Pg 4 Free text Larry Beesley : Building Open 4 x
Pg 4 Free text Larry Beesley : Building Open 4 x x
Pg 4 Free text Larry Beesley : Building Open 4 x x
Pg 4 Free text Larry Beesley : Building Open 4 x x
Pg 4 Free text Larry Beesley : Building Open 4 4200 lb hold downs
Pg 4 Line Larry Beesley : Building Open 4
Pg 4 Line Larry Beesley : Building Open 4
Pg 4 Line Larry Beesley : Building Open 4
Pg 4 Line Larry Beesley : Building Open 4
Pg 4 Free text Larry Beesley : Building Open 4 crawl space.
Pg 4 Line Larry Beesley : Building Open 4
Pg 4 Free text Larry Beesley : Building Open 4 See the foundation plan for the crwl Space
Pg 4 Line Larry Beesley : Building Open 4
Pg 4 Line Larry Beesley : Building Open 4
Pg 4 Free text Larry Beesley : Building Open 4 x
Pg 4 Free text Larry Beesley : Building Open 4 x
Pg 4 Free text Larry Beesley : Building Open 4 2800 lb hold dows
Pg 4 Line Larry Beesley : Building Open 4
Pg 4 Line Larry Beesley : Building Open 4
Pg 4 Free text Larry Beesley : Building Open 4 Rebar: 8' Wall-Horizontal & Vertical 24" O.C. with 2 in Top 12"
Rebar: 4' Wall-Horizontal & Vertical 24" O.C. with 1 in Top 6"
Pg 4 Stamp Larry Beesley : Building Open 4 Approved - Building Inspector
Pg 5 Free text Larry Beesley : Building Open 5 3' landing
Pg 5 Line Larry Beesley : Building Open 5
Pg 5 Free text Larry Beesley : Building Open 5 2800 lb hold downs
Pg 5 Line Larry Beesley : Building Open 5
Pg 5 Line Larry Beesley : Building Open 5
Pg 5 Line Larry Beesley : Building Open 5
Approval of plans does not constitute approval of variance from code
Page Reference Annotation
Type
Author : Department Status Page Review Comments Applicant Response Comments
Pg 5 Line Larry Beesley : Building Open 5
Pg 5 Free text Larry Beesley : Building Open 5 see crawl space plan
Pg 5 Line Larry Beesley : Building Open 5
Pg 5 Free text Larry Beesley : Building Open 5 Attic Access 22"x30" minimum access where attic clear height
exceeds 30" (R807)
Pg 5 Ellipse Larry Beesley : Building Open 5
Pg 5 Ellipse Larry Beesley : Building Open 5
Pg 5 Line Larry Beesley : Building Open 5
Pg 5 Free text Larry Beesley : Building Open 5 smoke detectors need to be 3' away from bathrom doors and
the end of fan blades
Pg 5 Line Larry Beesley : Building Open 5
Pg 5 Line Larry Beesley : Building Open 5
Pg 5 Free text Larry Beesley : Building Open 5 See the other floor plan that is for the crawl space .
Pg 5 Free text Larry Beesley : Building Open 5 Portal framing required on both overhead doors
Pg 5 Stamp Larry Beesley : Building Open 5 Approved - Building Inspector
Pg 6 Free text Larry Beesley : Building Open 6 Damp proofing/Waterproofing to finish grade. R406.1 (fnd.
extends 6" min above grade R404.1.6.1)
Pg 6 Stamp Larry Beesley : Building Open 6 Approved - Building Inspector
Pg 7 Stamp Larry Beesley : Building Open 7 Approved - Building Inspector
Approval of plans does not constitute approval of variance from code