HomeMy WebLinkAboutPERMIT DRAWINGS - 22-00693 - Teton River Lofts - Fire AlarmIU IHt WtSI 13UUNUAKY LINE UH URUVLK SUBUIVINUN, MAUISUN LUUN I Y, IUAHU; , `r-., W I „A60w v, W1 , `0'` V "v, IFI" W ,
THENCE SOUTHERLY AND WESTERLY ALONG THE BOUNDARY LINE OF SAID GROVER
SUBDIVISION THE FOLLOWING TWO (2) COURSES: (1) THENCE S.00°13'42"E. 340.00 PUSUANT TO IDAHO CODE, TITLE 55, CHAPTER 15
FEET; (2) THENCE S.89°32'16"W. 330.00 FEET; THENCE N.00°13'42"W. 200.00 FEET;
THENCE S.89°32'16"W.437.43 FEET TO THE POINT OF BEGINNING, CONTAINING 3.989 PART OF NORTHWEST QUARTER SECTION 20, TOWNSHIP, 6 NORTH, RANGE 40 EAST, BOISE MERIDIAN
ACRES. I CITY OF REXBURG, MADISON COUNTY, IDAHO
NORTHWEST CORNER SECTION 20
TOWNSHIP 6 NORTH, RANGE 40 EAST, BOISE MERIDIAN
INSTRUMENT NO_404639
189.68'
10.07'
L2 � I _ N89- 13'47"E Y
20-00735 20-00741
v N Al A2
I— 24' —I
NI 20-00742
z A3
P.O.B.
20-00743 II IICURB&GUTTER
A4
C.A.
LE6END
20-00744
131
n 'ALL EAST TO WEST BEARI NGS ON BUII
17' ALL NORTH TO SOUTH BEARI NGS ARE
•ALL EAST TO WEST BEARINGS O N BUII
1.34'1.34' ALL NORTH TO SOUTH BEARIN GS ARE
/
T
LOT 1
GROVER SUBDIVISION
INSTRUMENT N0.394710
1. THE TETON RIVER FLATS PLANNED UNIT DEVELOPMENT IS
EXISTING 10'GAS EASEMENT
EASTLORENESTREET o
— SECTION LINE
AND ARE SUBJECT TO RECIPROCAL EASEMENTS FOR UTILITIES
INSTRUMENT No. 438675
INSTALLATIONS, CONNECTIONS, MAINTENANCE AND REPAIR.
PROPOSED BUILDING
N89" 32' 16"E-77193'
^
no
BOUNDARY
2. THE PLAT IS SUBJECT TO THE CONDOMINIUM PROPERTY ACT,
z
^' 2 Z
56.62'. 54.33' �9-54.33'
54.32'
3. NO APPROVAL SHALL BE GRANTED BY ANY HOMEOWNERS
I
. 1 7 7. 7
10.07'
--{
� 7.55' C.A.
7.57' 10.06' �I 21-00350
I 21-00349
21-00351
NB 40_34"E 7
o CAP MARKED P.L.S. 9369
4. LOT AND UNIT OWNERS SHALL BE REQUIRED TO
B3 84
❑ FOUND 1/2" IRON ROD WITH
21-00352 21-00353
21-00392
21-00393
FOUND ALUMINUM CAP
20-0 7 5
IB2I
B5
B6 B7
D1
D2
INSTRUMENT NO. 404649 R -O -W RIGHT-OF-WAY
C.A.
4F'
T
DESCRIPTION OF LIMITED COMMON AREA:
6. THE PHYSICAL BOUNDARIES OF THE BUILDING UNITS ARE THE
SIDEWALK 1O
d
INTERIOR SURFACES OF THE PERIMETER WALLS, FLOORS,
1. THE STAIRS AND AREA IMMEDIATELY IN FRONT OF THE ENTRANCE TO EACH UNIT. THESE AREAS
CEILINGS, WINDOWS AND DOORS THEREOF, AND THE INTERIOR
SHALL BE APPURTENANCE FOR THE EXCLUSIVE USE OF THE ADJOINING UNITS ONLY.
�.I
7.49' 1
I. _ 1
IMPROVEMENTS THEREOF CONTAINED. NOT WITH STANDING
SUCH MARKINGS, THE FOLLOWING ARE NOT PART OFA "UNIT
THOSE PORTIONS OF THE TETON RIVER FLATS PLANNED UNIT DEVELOPMENT PROPERTY AS FOLLOWS:
394
21-00395
THE INTERIOR SURFACE THEREOF, OF A PERIMETER WALL,
1. ANY PROPERTY WHICH IS NOT INCLUDED WITH THE UNITS.
SIDEWALK
2. EASEMENT THROUGH THE UNITS FOR UTILITY SERVICES TO THE UNITS AND COMMON AREAS.
FD3
D4
PIPES, VENTS, DUCTS, FLUTES, CHUTES, CONDUITS, WIRES
EXISTING 10' P.U.E. C.A.
(EXCEPT THE OUTLETS THEREOF WHEN LOCATED WITHIN THE
CURB &GUTTER
UNIT), THE INTERIOR SURFACES OF A PERIMETER WINDOW OR
BUILDING SHALL BE COMMON AREA TO BE OWNED AND MAINTAINED BY THE HOA.
DOOR MEANS AT THE POINTS AT WHICH SUCH SURFACES ARE
'I ,I INSTRUMENT No. 264672
I I I I I I
1 1 1 1
1 1 1 1 1 1 1 1 1
WINDOWS AND DOORS THEMSELVES ARE PART OF THE
THERE ARE 25 BUILDINGS, EACH WITH 4 UNITS, FOR A TOTAL OF 100 UNITS SO EACH INDIVIDUAL UNIT HAS
COMMON AREAS HEREIN DEFINED.
HG PARTNERS LLC
INSTRUMENT NO. 239455
P.O.B. POINT OF BEGINNING
NOTES
I" ROADWAY CENTERLINE
1. THE TETON RIVER FLATS PLANNED UNIT DEVELOPMENT IS
SUBJECT TO A BLANKET EASEMENT FOR ALL UTILITIES. LOTS HAVE
— SECTION LINE
AND ARE SUBJECT TO RECIPROCAL EASEMENTS FOR UTILITIES
INSTALLATIONS, CONNECTIONS, MAINTENANCE AND REPAIR.
PROPOSED BUILDING
^
no
BOUNDARY
2. THE PLAT IS SUBJECT TO THE CONDOMINIUM PROPERTY ACT,
z
^' 2 Z
TITLE 55, CHAPTER 15, IDAHO CODE.
G EXISTING PUBLIC UTILITY
EASEMENT AS NOTED
3. NO APPROVAL SHALL BE GRANTED BY ANY HOMEOWNERS
�m SECTION CORNER AS NOTED
ASSOCIATION OR ARCHITECTURAL COMMITTEE THAT SHALL
b.1VIOLATE
THE REXBURG CITY CODE.
0 PLACED 1/2" IRON ROD WITH
o CAP MARKED P.L.S. 9369
4. LOT AND UNIT OWNERS SHALL BE REQUIRED TO
INCORPORATE LOW VOLUME IRRIGATION SYSTEMS
❑ FOUND 1/2" IRON ROD WITH
THROUGHOUT THEIR LANDSCAPED AREAS.
NO CAP
FOUND ALUMINUM CAP
5. EACH OWNER SHALL HAVE THE RIGHT OF INGRESS AND
WEST QUARTER CORNER SECTION 20
TOWNSHIP 6 NORTH, RANGE 40 EAST, C.A. COMMON AREA
EGRESS OVER, UPON AND ACROSS THE COMMON AREA
BOISE MERIDIAN
NECESSARY TO ACCESS THE UNIT, PROVIDE PUBLIC UTILITIES
INSTRUMENT NO. 404649 R -O -W RIGHT-OF-WAY
STREET LIGHT EASEMENT, PARKING AND OTHER SUCH COMMON
USES, AND SUCH RIGHTS SHALL BE APPURTENANT TO AND PASS
WITH TITLE TO EACH UNIT.
DESCRIPTION OF LIMITED COMMON AREA:
6. THE PHYSICAL BOUNDARIES OF THE BUILDING UNITS ARE THE
THOSE PORTIONS OF COMMON PROPERTY AS FOLLOWS:
INTERIOR SURFACES OF THE PERIMETER WALLS, FLOORS,
1. THE STAIRS AND AREA IMMEDIATELY IN FRONT OF THE ENTRANCE TO EACH UNIT. THESE AREAS
CEILINGS, WINDOWS AND DOORS THEREOF, AND THE INTERIOR
SHALL BE APPURTENANCE FOR THE EXCLUSIVE USE OF THE ADJOINING UNITS ONLY.
SURFACES OF SKYLIGHTS, TOGETHER WITH ALL FIXTURES AND
DESCRIPTION OF COMMON AREA:
IMPROVEMENTS THEREOF CONTAINED. NOT WITH STANDING
SUCH MARKINGS, THE FOLLOWING ARE NOT PART OFA "UNIT
THOSE PORTIONS OF THE TETON RIVER FLATS PLANNED UNIT DEVELOPMENT PROPERTY AS FOLLOWS:
R
BEARING WALLS COLUMNS, FLOORS, AND ROOFS (EXCEPT FOR
THE INTERIOR SURFACE THEREOF, OF A PERIMETER WALL,
1. ANY PROPERTY WHICH IS NOT INCLUDED WITH THE UNITS.
FLOOR, OR CEILING). FOUNDATIONS, CENTRAL HEATING
2. EASEMENT THROUGH THE UNITS FOR UTILITY SERVICES TO THE UNITS AND COMMON AREAS.
SYSTEMS, AND OTHER SERVICES USED BY MORE THAN ONE UNIT,
3. INSTALLATIONS THAT ARE REQUIRED TO PROVIDE UTILITY AND OTHER SERVICES TO MORE THEN ONE
PIPES, VENTS, DUCTS, FLUTES, CHUTES, CONDUITS, WIRES
UNIT OR THE COMMON AREAS.
(EXCEPT THE OUTLETS THEREOF WHEN LOCATED WITHIN THE
4. STRUCTURAL SUPPORT EASEMENTS IN ANY PORTION OF A UNIT CONTRIBUTING TO SUPPORT OF A
UNIT), THE INTERIOR SURFACES OF A PERIMETER WINDOW OR
BUILDING SHALL BE COMMON AREA TO BE OWNED AND MAINTAINED BY THE HOA.
DOOR MEANS AT THE POINTS AT WHICH SUCH SURFACES ARE
DESCRIPTION OF UNITS:
LOCATED WHEN SUCH SURFACES ARE CLOSED, THE PHYSICAL
WINDOWS AND DOORS THEMSELVES ARE PART OF THE
THERE ARE 25 BUILDINGS, EACH WITH 4 UNITS, FOR A TOTAL OF 100 UNITS SO EACH INDIVIDUAL UNIT HAS
COMMON AREAS HEREIN DEFINED.
AN UNDIVIDED OWNERSHIP SHARE OF 1/100 (1%) OF THE COMMON AREA. EACH UNIT CONSISTS OF THAT
C.A.
C.A.
L15
24.]0' I 26'
21-00402 21-00403
C3
0
21-00400
C1
C4
SIDEWALK
f21-00401
C.A. C2
C.A.
�EXISTING 10' GAS EASEMENT
INSTR.No.438675
CURB & GUTTER
21-00396 21-00397
DS D6
au
SIDEWALK e
1 — I ry
21-00398
D7
16.91' H -L ,-1
r 7.49-
S89° 32' 16"W 330.00'
0
LOT 3
GROVER SUBDIVISION
INSTRUMENT N0.394710
�1
N
WE
6
�S550HPL LANOgU�
aeo`' 0S'GSTEgFO F�o9 n
9369 r
21-00399
D8
FOUND 1/2" IRON
LS 827
L512
Lin.
L.
L
L:
L.
L'
LI
L'
J U
D
—L-
C)
M L1
W L1
N L1
V
L1
eH
o u
u
O
z "
Oa
'^ m
Es 0
m m Z
O vDZ
J � W
>�
¢,
Oz
�
AGL
�-� NGI
yyn'(�S`c CIVIL PLANI`
@ -<4 "L"a IDAHO FAILR(208) 542-26