Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
REDLINED PLANS & DOCS - 22-00472 - 152 N Center St - Solar Panels
Author Name Author Email Author Phone No.: Larry Beesley Larry.Beesley@rexburg.org 208-372-2176 Description : 152 N Center St - Solar Panels Address : 152 N Center St Application Type : Document Filename : zollinger- stamped letter.pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments Pg 1 Free text Larry Beesley : Building Open 1 We need to know if the roof is truss or rafters and not just assumed, but have some pictures showing that the engineer has the correct information. # 22-00472 Solar Panels Please digitally re-submit all pages of the plan set in response to requested revisions for our next review cycle, with noted items resolved. Report Date: 07.18.2022 Approval of plans does not constitute approval of variance from code Page 1 of 1 Powered by TCPDF (www.tcpdf.org) 76 North Meadowbrook Drive Scott E. Wyssling, PE Alpine, UT 84004 Jon P. Ward, SE, PE office (201) 874-3483 Gregory T. Elvestad, PE swyssling@wysslingconsulting.com June 15, 2022 Current Insight 2852 W. Amini Way South Jordan, UT 84095 Re: Engineering Services Zollinger Residence 152 N Center, Rexburg ID 4.745 kW System To Whom It May Concern: We have received information regarding solar panel installation on the roof of the above referenced structure. Our evaluation of the structure is to verify the existing capacity of the roof system and its ability to support the additional loads imposed by the proposed solar system. A. Site Assessment Information 1. Site visit documentation identifying attic information including size and spacing of framing for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information will be utilized for approval and construction of the proposed system. B. Description of Structure: Roof Framing: Assumed 2 x 6 dimensional lumber spaced at 24” on center Roof Material: Composite Asphalt Shingles Roof Slope: 18 degrees Attic Access: Accessible Foundation: Permanent C. Loading Criteria Used • Dead Load o Existing Roofing and framing = 7 psf o New Solar Panels and Racking = 3 psf o TOTAL = 10 PSF • Dead Load o Existing Roofing and framing = 7 psf o New Solar Panels and Racking = 3 psf o TOTAL = 10 psf • Live Load = 20 psf (reducible) – 0 psf at locations of solar panels • Ground Snow Load = 50 psf • Wind Load based on ASCE 7-16 o Ultimate Wind Speed = 105 mph (based on Risk Category II) o Exposure Category C Analysis performed of the existing roof structure utilizing the above loading criteria is in accordance with the 2018 IRC, including provisions allowing existing structures to not require strengthening if the new loads do not exceed existing design loads by 105% for gravity elements and 110% for seismic elements. This analysis indicates that the existing framing will support the additional panel loading without damage, if installed correctly. We need to know if the roof is truss or rafters and not just assumed, but have some pictures showing that the engineer has the correct information. Page 2 of 2 D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent Ironridge installation manual. If during solar panel installation, the roof framing members appear unstable or deflect non- uniformly, our office should be notified before proceeding with the installation. 2. The maximum allowable withdrawal force for a 5/16” lag screw is 235 lbs per inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications. Based on a minimum penetration depth of 2½”, the allowable capacity per connection is greater than the design withdrawal force (demand). Considering the variable factors for the existing roof framing and installation tolerances, the connection using one 5/16” diameter lag screw with a minimum of 2½” embedment will be adequate and will include a sufficient factor of safety. 3. Considering the wind speed, roof slopes, size and spacing of framing members, and condition of the roof, the panel supports shall be placed no greater than 48” on centers. 4. Panel supports connections shall be staggered to distribute load to adjacent framing members. Based on the above evaluation, this office certifies that with the racking and mounting specified, the existing roof system will adequately support the additional loading imposed by the solar system. This evaluation is in conformance with the 2018 IRC, current industry standards, and is based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. Very truly yours, Scott E. Wyssling, PE Idaho License No. 18974 C O N T R A C T O R I N F O R M A T I O N 3 1 5 3 E 1 7 T H S T . A M M O N I D . 8 3 4 0 6 ( 2 0 8 ) - 7 0 9 - 7 2 0 7 C L I E N T I N F O R M A T I O N P R O J E C T D E T A I L S A P P L I C A B L E C O D E S SHEET INDEX A L L W O R K T O C O M P L Y W I T H T H E F O L L O W I N G C O D E : PV-1 PROJECT SUMMARYPV-2 SITE PLANPV-3 SINGLE LINE DIAGRAMAPPENDIX:- ELECTRICAL CALCULAT I O N S - PANEL CUT SHEET- OPTIMIZER CUT SHEET- INVERTER CUT SHEET- RACKING CUT SHEET- MOUNTING CUT SHEET- ADDITIONAL CUT SHEE T S - PLACARDS & STICKERS V I C I N I T Y M A P ALL CONDUIT TO RUN ON EXTERIOR O F H O U S E U N L E S S O T H E R W I S E N O T E D OCCUPANCY: R-3CONSTRUCTION TYPE: V-BUNSPRINKLERED1. ALL MODULES WILL BE GROUNDE D I N A C C O R D A N C E W I T H T H E C O D E A N D T H E MANUFACTURES INSTALLATION I N S T R U C T I O N S . 2. ALL PLACARDS REQUIRED BY NEC 2 0 1 7 C O D E M A C H I N E P R I N T E D L E T T E R S I N A C O N T R A S T I N G COLOR TO THE PLACARD.3. LIQUID TIGHT FLEXIBLE CONDUIT S H A L L B E S U N L I G H T R E S I S T A N T . 4. ELECTRICAL INSTALLATION WILL C O M P L Y W I T H N E C 2 0 1 7 C O D E . 5. ALL SOLAR MODULES EQUIPMEN T A N D M E T A L L I C C O M P O N E N T S A R E T O B E B O N D E D . 6. ALL PLUMBING AND MECHANICA L R O O F V E N T S T O C L E A R F R O M P H O T O V O L T A I C A R R A Y , O R EXTEND ABOVE SOLAR PANELS.7. SOLAR PHOTOVOLTAIC SYSTEM T O B E I N S T A L L E D O N R E S I D E N T I A L S T R U C T U R E . 8. DESIGN COMPLYING WITH THE IB C 2 0 1 8 C O D E A N D A L L L O C A L O R D I N A N C E S A N D P O L I C I E S . 9. THE PROJECT HAS BEEN DESIGNE D T O W I T H S T A N D A M I N I M U M 1 1 0 M P H W I N D L O A D . 10. THE SYSTEM WILL NOT BE INTERC O N N E C T E D U N T I L A P P R O V A L F R O M T H E L O C A L JURISDICTION AND A UTILITY IS O B T A I N E D . 11. IF THE MAIN SERVICE PANEL DOE S N O T H A V E V E R I F I A B L E G R O U N D I N G E L E C T R O D E , I T I S T H E CONTRACTORS RESPONSIBILITY T O I N S T A L L S U P P L E M E N T A L G R O U N D I N G E L E C T R O D E . 12. EACH MODULE WILL BE GROUND E D U S I N G T H E S U P P L I E D C O N N E C T I O N P O I N T S I D E N T I F I E D ON THE MODULE AND THE MAN U F A C T U R E R S I N S T A L L A T I O N I N S T R U C T I O N S . 13. A LADDER SHALL BE IN PLACE FO R I N S P E C T I O N I N C O M P L I A N C E W I T H O S H A R E G U L A T I O N S . 14. PROPER ACCESS AND WORKING C L E A R A N C E W I L L B E P R O V I D E D " W A R N I N G : P V P O W E R SOURCE" TO BE PLACED EVERY 1 0 F T . 15. GFCI PROTECTION IN INVERTER. N T S P V - 1 0 6 / 0 1 / 2 0 2 2 A M R R - 1 J A C K Z O L L I N G E R 1 5 2 N C E N T E R ( 2 0 8 ) 2 0 1 - 5 5 1 6 R E X B U R G , I D 8 3 4 4 0 1 3 - U R E C O F A M 3 6 5 E 7 G - B B ( 3 6 5 W ) P H O T O V O L T A I C M O D U L E S 1 - S O L A R E D G E S E 6 0 0 0 H - U S ( 6 0 0 0 W ) I N V E R T E R S Y S T E M S I Z E : 4 . 7 4 5 K W D C N E C 2 0 1 7 C O D E I B C / I R C / I F C 2 0 1 8 C O D E S i g n e d 6 - 1 5 - 2 2 N G N G A A A 1 2 3 A C D I S C O N N E C T W I T H I N 3 ’ O F U T I L I T Y M E T E R B B B D E E L E C T R I C A L E Q U I P M E N T C A L L O U T S 4,745W TOTAL SOLAR AR R A Y 13 URECO FAM365E76-BB (365W) PA N E L S 1 STRING OF 13 MODULES CONNEC T E D I N S E R I E S @ 6 . 0 I N V E R T E R WIRE AND CONDUIT CAL L O U T S S O L A D E C K M O D E L 0 7 8 3 - 4 1 J U N C T I O N B O X / R O O F P E N E T R A T I O N , 6 0 0 V 6 . 0 k W I N V E R T E R U N G R O U N D E D S O L A R E D G E S E 6 0 0 0 H - U S ( 2 4 0 V ) I N V E R T E R 2 4 0 V A C , 2 5 A , N E M A 3 R , U L L I S T E D , ( W / I N T E G R A T E D D C D I S C O N N E C T ) W I T H I N T E G R A T E D G F P , W / I N T E G R A T E D A F P (2) #10 AWG PV/RHW-2 IN FRE E A I R (1) #6 AWG BARE COPPER GN D I N F R E E A I R (2) #10 AWG THWN-2(1) #10 AWG THWN-2 GND IN 3 / 4 " E M T / F M C (3) #6 AWG THWN-2(1) #10 AWG THWN-2 GND IN 3 / 4 " E M T S 4 4 0 O P T I M I Z E R O N E P E R P A N E L B I - D I R E C T I O N A L U T I L I T Y M E T E R A B C D 123 2 0 0 A ( E ) M A I N S E R V I C E P A N E L U R E C O F A M 3 6 5 E 7 G - B B M O D U L E E A T O N S A F E T Y S W I T C H , # D G 2 2 2 N R B 2 5 0 V A C , 6 0 A , N E M A 3 R , F U S E D , U L , N E M A , C S A , N O M C E R T I F I E D W / 4 0 A F U S E S E F G 4 C F GNG200A S U P P L Y S I D E C O N N E C T I O N W I T H L I S T E D I N S U L A T I O N P I E R C I N G C O N D U C T O R S I N A C C O R D A N C E W I T H N E C 7 0 5 . 1 2 ( A ) A N D 2 3 0 . 8 2 (3) #6 AWG THWN-2(1) #8 AWG THWN-2 GND IN 3/ 4 " E M T 4 C O N T R A C T O R I N F O R M A T I O N 3 1 5 3 E 1 7 T H S T . A M M O N I D . 8 3 4 0 6 ( 2 0 8 ) - 7 0 9 - 7 2 0 7 C L I E N T I N F O R M A T I O N N T S P V - 3 0 6 / 0 1 / 2 0 2 2 A M R R - 0 J A C K Z O L L I N G E R 1 5 2 N C E N T E R ( 2 0 8 ) 2 0 1 - 5 5 1 6 R E X B U R G , I D 8 3 4 4 0 MODULE:URECO FAM365E7G-BB ( 3 6 5 W ) Voc= 40.7V Isc= 11 . 4 3 A Vmp= 34.2V Imp= 1 0 . 6 8 A MOUNTRAFTER4'4'MAXSPAN C O N T R A C T O R I N F O R M A T I O N 3 1 5 3 E 1 7 T H S T . A M M O N I D . 8 3 4 0 6 ( 2 0 8 ) - 7 0 9 - 7 2 0 7 C L I E N T I N F O R M A T I O N N T S P V - 2 0 6 / 0 1 / 2 0 2 2 A M R R - 1 J A C K Z O L L I N G E R 1 5 2 N C E N T E R ( 2 0 8 ) 2 0 1 - 5 5 1 6 R E X B U R G , I D 8 3 4 4 0 AERIAL VIEWMOUNTING PATTER N ROOF DE S C R I P T I O N ROOFTYPE A R R A Y P I T C H A Z I M U T H #1SHINGLE 1 8 ° 9 0 ° R O O F # 1 1 8 " C L E A R A N C E 3' WALKWAY D R I V E W A Y N CENTER ST ( E X T E R I O R ) M E T E R M A I N S E R V I C E P A N E L A C D I S C O N N E C T I N V E R T E R S i g n e d 6 - 1 5 - 2 2 Module Inverter AC 4 Brand:URECO Brand:# of Total Mods 13 Model #FAM365E7G-BB Model ## of Strings 1 Vmp 34.2 V 12,000 W Condctr. Size #10 Voc:40.7 V 480 V Condctr. Type THWN-2 Imp:10.68 A 6,000 W Condctr. Mtrl Cu Isc:11.43 A 25 A Output Voltage 12,000 Tvoc:-0.28 V/°C Output Current 480 Tisc:0.04 A/°C Icont 600 °C °F Max Output Mods 7800 0 32 OCP Size 40 40 104 Qty.Description Inv. Eff.Inv. Power A Module 1 13 Icont 600 Inverter 1 1 96.5 6000 30 Deg C Ampacity 30 Module 2 B Inverter 2 Icont 600 Module 3 Start Ampacity 30 Inverter 3 Temperature Derate 0.91 6000 Total System Pwr.Conduit Fill Derate 1 Derated Ampacity 27.3 String 1 String 2 String 3 DC 4 Total Inverter output AC1 C Module INV 1 INV 1 INV 1 INV 1 Icont 24.55 Icont 600 # of Modules 13 0 0 0 Voltage 480 Ampacity 30 Condctr. Size #10 #10 #10 #10 Conductor Size 6 D Condctr. Type THWN-2 THWN-2 THWN-2 THWN-2 Conductor Type thwn-2 Icont 600 Condctr. Mtrl Cu Cu Cu Cu Aluminum / Copper cu OCP Size 40 Vmp 445 0 0 0 Cond Temp Rating 90 EGC Size 10 Voc 529 0 0 0 A Imp 10.68 0 0 0 Icont * 1.25 = Amps 31.25 AC 4 Isc 11.43 0 0 0 11.43 OCP Size 40 Output Current 25 Icont=isc*1.25 14.2875 0 0 0 42.864 B Voltage 240 Icont * 1.25 = Amps 31.25 Condctr. Size 6 A 30 deg C Ampacity 0.75 Condctr. Type THWN-2 Icont*1.25=amps 14.2875 0 0 0 C Condctr. Material Cu 30 Deg C Ampacity 30 30 30 30 Icont (Amps)25 Condctr. Temp. Rating 90 B Start Ampacity 75 A Icont String 11.43 0 0 0 Temp Derate 0.91 Icont 31.25 Start Ampacity 30 30 30 30 Conduit Fill Derate 1 OCP Size 40 Temperature Derate 0.75 0.75 0.75 0.75 Derated Ampacity B Conduit Fill Derate 1 1 1 1 D Icont 31.25 Derated Ampacity 22.5 22.5 22.5 22.5 Icont*1.25 = Amps 30 Deg. C Ampacity 75 C 30 deg C Ampacity 75 C Icont*1.25=amps 14.2875 0 0 0 E Output Current 25 Ampacity 30 30 30 30 EGC/GEC +10 Start Ampacity 75 D Temperature Derate 0.91 Icont*1.25=amps 14.2875 0 0 0 Conduit Fill Derate 1 OCP Size 15 0 0 0 Derated Ampacity 68.25 D Icont 31.25 30 Deg. C Ampacity 75 E EGC/GEC =10 Branch Characteristics Inverter(s) Output URECO FAM365E7G-BB SOLAREDGE SE6000H String Characteristics DC Strings Electrical Properties System Properties Min. Ambient Temp: Max Ambient Temp: Max PV DC Cap Max DC V Cont AC Power to Grid Cont AC Current to Grid SE6000 SolarEdge Key Features FAM_E7G-BB / 120 cells 345W - 365 W Mono-Crystalline PV Module EN URE Peach module uses URE state-of -the art cell cutting technology, and advanced module manufacturing experiences. Positive power tolerance +0 ~ +5 watt 100% EL inline inspection Better module reliability Withstand heavy loading front load 5400 Pa & rear load 2400 Pa Excellent low light performance 3.5% relative eff. Reduction at low (200W/m²) Design for 1000 VDC Reduce the system BOS effectively www.urecorp.com For more information, please visit us at www.urecorp.comCopyright © 2021 URE Corp. All rights reserved EN Engineering Drawing (mm)Dependence on Irradiance Reliability with Warranty Operating Conditions Item Mechanical Load Maximum System Voltage Series Fuse Rating Operating Temperature Specification 5400 Pa 1000 VDC 20 A -40 to 85 °C : With assembly tolerance of ± 2 mm [ ± 0.08�] : With assembly tolerance of ± 0.8 mm [ ± 0.03�]2 1 1 year 97.5% 100% 90% 80% 0% 0 5 10 15 Years Li n e a r p e r f o r m a n c e w a r r a n t y 20 25 URE Additional value from warranty Standard tiered warranty 25 year 82.4% Mechanical Data Item Dimensions Weight Solar Cell Front Glass Frame Junction Box Packaging Configuration Specification White toughened safety glass, 3.2mm thickness Black anodized aluminum profile IP ≥67, 3 diodes Cable 31 pcs Per Pallet, 806 pcs per 40’ HQ container 1762 mm (L)1 x 1048 mm (W)1 x 35 mm (D)2 / 69.37�(L)1 x 41.26�(W)1 x 1.38�(D)2 19.6 kg / 43.21 lbs Temperature Characteristics *Nominal module operating temperature (NMOT): Air mass AM 1.5, irradiance 800W/m², temperature 20°C, windspeed 1 m/s. *Reduction in efficiency from 1000W/m² to 200W/m² at 25°C: 3.5 ± 2%. Item Nominal Module Operating Temperature Temperature Coefficient of Isc Temperature Coefficient of Voc Temperature Coefficient of Pmax 45 °C ± 2°C 0.048 % / °C -0.27 % / °C -0.35 % / °C Specification500mm (cable length can be customized), 4mm2 Electrical Data *Standard Test Condition (STC): Cell Temperature 25 °C, Irradiance 1000 W/m², AM 1.5 *Values without tolerance are typical numbers.Measurement tolerance: ± 3% Model - STC Maximum Rating Power (Pmax) Module Efficiency Open Circuit Voltage (Voc) Maximum Power Voltage Short Circuit Current (Isc) Maximum Power Current [W] [%] [V] [V] [A] [A] FAM345E7G-BB 18.68 345 39.90 33.40 11.13 10.33 FAM350E7G-BB 18.95 350 40.10 33.60 11.19 10.42 FAM355E7G-BB 19.22 355 40.30 33.80 10.51 11.26 FAM360E7G-BB 19.50 360 40.50 34.00 10.59 11.35 FAM365E7G-BB 19.77 365 40.70 34.20 10.68 11.43 Mono / 83 mm x 166mm Connectors Type MC4 Compatible 0 2 4 6 8 10 0 5 10 15 20 25 30 35 40 45 C u r r e n t [A ] Voltage [V]Temperature 25�C 600 W/m2 800 W/m2 1000 W/m2 400 W/m2 200 W/m294 0 ±1 40 0 ±1 17 6 2± 1 1008±1 998±11048±1 Junction box FRONT VIEW BACK VIEW C B A A 35 11 35 B-Mounting Hole 4 place C-Mounting Hole 4 place A-A Frame 14 9 10 7 25Output warranty Years 25Product Gurantee Years Taipei Office 9F, NO. 295, Sec. 2, Tiding Blvd., Neihu Dist., Taipei 11493, Taiwan e-mail : sales@urecorp.com Tel : +886-2-2656-2000 Fax : +886-2-2656-0593 Headquarters No. 7, Li-Hsin 3rd Road, Hsinchu Science Park Hsinchu city 30078, Taiwan Tel : +886-3-578-0011 Fax : +886-3-578-1255 For more information, please visit us at www.urecorp.com URECO_US_Peach_FAM_E7G_V1_3.2_35mm_BS_EN_210520Copyright © 2021 URE Corp. All rights reserved Power Optimizer For North America S440, S500 25 YEAR WARRANTY PV power optimization at the module level Specifically designed to work with SolarEdge residential inverters Faster installations with simplified cable management and easy assembly using a single bolt Detects abnormal PV connector behavior, preventing potential safety issues* Module-level voltage shutdown for installer and firefighter safety Superior efficiency (99.5%) Flexible system design for maximum space utilization Compatible with bifacial PV modules Meets NEC requirements for arc fault protection (AFCI) and Photovoltaic Rapid Shutdown System (PVRSS) Mitigates all types of module mismatch loss, from manufacturing tolerance to partial shading * Expected availability in 2022 solaredge.com P O W E R O P T I M I Z E R Power Optimizer For North America S440, S500 S440 S500 Unit INPUT Rated Input DC Power(1) 440 500 W Absolute Maximum Input Voltage (Voc) 60 Vdc MPPT Operating Range 8 - 60 Vdc Maximum Short Circuit Current (Isc) of Connected PV Module 14.5 15 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.6 % Overvoltage Category II OUTPUT DURING OPERATION Maximum Output Current 15 Adc Maximum Output Voltage 60 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer 1+/-0.1 Vdc STANDARD COMPLIANCE Photovoltaic Rapid Shutdown System NEC 2014, 2017 & 2020 EMC FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741 Material UL94 V-0, UV Resistant RoHS Yes Fire Safety VDE-AR-E 2100-712:2013-05 INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Dimensions (W x L x H) 129 x 153 x 30 / 5.07 x 6.02 x 1.18 mm / in Weight (including cables) 655 / 1.5 gr / lb Input Connector MC4(2) Input Wire Length 0.1 / 0.32 m / ft Output Connector MC4 Output Wire Length (+) 2.3, (-) 0.10 / (+) 7.54, (-) 0.32 m / ft Operating Temperature Range(3) -40 to +85 ˚C Protection Rating IP68 / Type6B Relative Humidity 0 - 100 % (1) Rated power of the module at STC will not exceed the power optimizer Rated Input DC Power. Modules with up to +5% power tolerance are allowed (2) For other connector types please contact SolarEdge (3) For ambient temperature above +70°C / +158°F power de-rating is applied. Refer to Power Optimizers Temperature De-Rating Technical Note for more details PV System Design Using a SolarEdge Inverter Single Phase HD-Wave Three Phase for 208V grid Three Phase for 277/480V grid Minimum String Length (Power Optimizers) S440, S500 8 14 18 Maximum String Length (Power Optimizers) 25 50(4) Maximum Nominal Power per String 5700 (6000 with SE7600-US-SE11400-U) 6000 12750 W Maximum Allowed Connected Power per String (5) (Permitted only when the difference in connected power between strings is 1,000W or less) Refer to Footnote 5 One String 7200W 15,000W Two strings or more 7800W Parallel Strings of Different Lengths or Orientations Y (4) A string with more than 30 optimizers does not meet NEC rapid shutdown requirements; safety voltage will be above the 30V requirement (5) If the inverters rated AC power ≤ maximum nominal power per string, then the maximum power per string will be able to reach up to the inverters maximum input DC power. Refer to: https://www.solaredge.com/ sites/default/files/se-power-optimizer-single-string-design-application-note.pdf (6) It is not allowed to mix S-series and P-series Power Optimizers in new installations © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or r egistered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: February 8, 2022 DS-000018-NA. Subject to change without notice. Single Phase Energy Hub Inverter with Prism Technology For North America SE3000H-US / SE3800H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US(1) 12-25 YEAR WARRANTY Optimized battery storage with HD-Wave technology Record-breaking 99% weighted efficiency with 200% DC oversizing Small, lightweight, and easy to install Modular design, future ready with optional upgrades to: DC-coupled storage for full or partial home backup Built-in consumption monitoring Direct connection to the SolarEdge smart EVcharger Multi-inverter, scalable storage solution With enhanced battery power up to 10kW Integrated arc fault protection and rapid shutdown for NEC 2014,NEC 2017 and NEC 2020,per article 690.11 and 690.12 Embedded revenue grade production data, ANSI C12.20 Class 0.5 solaredge.com H O M E B A C K U P Single Phase Energy Hub Inverter with Prism Technology For North America SE3000H-US / SE3800H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US(1) SE3000H-US SE3800H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US UNITS OUTPUT - AC ON GRID Rated AC Power 3000 3800 @ 240V 3300 @ 208V 6000 @ 240V 5000 @ 208V 7600 10000 11400 @ 240V 10000 @ 208V W Maximum AC Power Output 3000 3800 @ 240V 3300 @ 208V 6000 @ 240V 5000 @ 208V 7600 10000 11400 @ 240V 10000 @ 208V W AC Frequency Range (min - nom - max) 59.3 - 60 - 60.5(2)Hz Maximum Continuous Output Current @ 240V 12.5 16 25 32 42 47.5 A Maximum Continuous Output Current @ 208V - 16 24 - - 48.5 A GFDI Threshold 1 A Total Harmonic Distortion (THD) <3 % Power Factor 1, adjustable -0.85 to 0.85 Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes Charge Battery from AC (if allowed) Yes Typical Nighttime Power Consumption <2.5 W OUTPUT - AC BACKUP(3) Rated AC Power in Backup Operation(4) 3000 3800 6000 7600 10000 10300 W 7600* 10300* AC L-L Output Voltage Range in Backup 211 - 264 Vac AC L-N Output Voltage Range in Backup 105 - 132 Vac AC Frequency Range in Backup (min - nom - max) 55 - 60 - 65 Hz Maximum Continuous Output Current in Backup Operation 12.5 16 25 32 42 43 A 32* 43* GFDI 1 A THD <5 % OUTPUT - SMART EV CHARGER AC Rated AC Power 9600 W AC Output Voltage Range 211 - 264 Vac On-Grid AC Frequency Range (min - nom - max) 59.3 - 60 - 60.5 Hz Maximum Continuous Output Current @240V (grid, PV and battery) 40 Aac INPUT - DC (PV AND BATTERY) Transformer-less, Ungrounded Yes Max Input Voltage 480 Vdc Nom DC Input Voltage 380 Vdc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600kΩ Sensitivity INPUT - DC (PV) Maximum DC Power @ 240V 6000 7600 12000 15200 22000 22800 W 15200* 22800* Maximum DC Power @ 208V - 6600 10000 - - 20000 W Maximum Input Current(5) @ 240V 8.5 10.5 16.5 20 27 31 Adc 20* 31* Maximum Input Current(5) @ 208V - 9 13.5 - - 27 Adc Max. Input Short Circuit Current 45 Adc Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 99 @ 240V 98.5 @ 208V % 2-pole Disconnection Yes *Supported with PN SExxxxH-USMMxxxxxx or SExxxxH-USMNxxxxxx (1) These specifications apply to inverters with part numbers SExxxxH-USSMxxxxx or SExxxxH-USSNxxxxxx and connection unit model number DCD-1PH-US-PxH-F-x (2) For other regional settings please contact SolarEdge support (3) Not designed for standalone applications and requires AC for commissioning. Backup functionality is only supported for 240V grid(4) Rated AC power in Backup Operation are valid for installations with multiple inverters. For a single backup inverter operation, rated AC power in Backup is 90% of the value stated (5) A higher current source may be used; the inverter will limit its input current to the values stated Single Phase Energy Hub Inverter with Prism Technology For North America SE3000H-US / SE3800H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US(1) SE3000H-US SE3800H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US UNITS INPUT - DC (BATTERY) Supported Battery Types SolarEdge Energy Bank, LG RESU Prime(6) Number of Batteries per Inverter Up to 3 SolarEdge Energy Bank, up to 2 LG RESU Prime Continuous Power(7) 6000 7600 10000 W Peak Power(7) 6000 7600 10000 W Max Input Current 16 20 26.5 Adc 2-pole Disconnection Yes SMART ENERGY CAPABILITIES Consumption Metering Built - in(8) Backup & Battery Storage With Backup Interface (purchased separately) for service up to 200A; Up to 3 inverters EV Charging Direct connection to Smart EV charger ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, Cellular(9), Wi-Fi (optional),SolarEdge Energy Net (optional) Revenue Grade Metering, ANSI C12.20 Built - in(8) Integrated AC, DC and Communication Connection Unit Yes Inverter Commissioning With the SetApp mobile application using built-in Wi-Fi Access Point for local connection DC Voltage Rapid Shutdown (PV and Battery) Yes, according to NEC 2014, NEC 2017 and NEC 2020 690.12 STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1741 PCS, UL1699B, UL1998, UL9540, CSA 22.2 Grid Connection Standards IEEE1547, Rule 21, Rule 14H Emissions FCC part 15 class B INSTALLATION SPECIFICATIONS AC Output and EV AC Output Conduit Size / AWG Range 1'' maximum / 14-4 AWG DC Input (PV and Battery) Conduit Size / AWG Range 1'' maximum / 14-6 AWG Dimensions with Connection Unit (H x W x D) 17.7 x 14.6 x 6.8 / 450 x 370 x 174 17.7 x 14.6 x 6.8 / 450 x 370 x 174 17.7 x 14.6 x 6.8 / 450 x 370 x 174 in / mm 17.7 x 14.6 x 6.8 / 450 x 370 x 174* Weight with Connection Unit 26 / 11.8 26 / 11.8 30.2 / 13.7 lb / kg 30.2 / 13.7* Noise < 25 < 25 < 25 < 50 dBA < 50* Cooling Natural Convection Operating Temperature Range -40 to +140 / -40 to +60(10) ˚F / ˚C Protection Rating NEMA 4 (6)The part numbers SExxxxH-USxMxxxxx only support the SolarEdge Energy Bank. The part numbers SExxxxH-USxNxxxxx support both SolarEdge Energy Bank and LG RESU Prime batteries Requires supporting inverter firmware(7)Discharge power is limited up to the inverter rated AC power for on-grid and backup applications (8)For consumption metering current transformers should be ordered separately: SECT-SPL-225A-T-20 or SEACT0750-400NA-20 units per box. Revenue grade metering is only for production metering (9)Information concerning the Data Plan's terms & conditions is available in the following link: https://www.solaredge.com/sites/default/files/se-communication-plan-terms-and-conditions-eng.pdf (10)Full power up to at least 50°C / 122°F; for power de-rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners.Date:06/2021 DS-000031-1.5-NAM.Subject to change without notice. RAIL SYSTEM 1/2”socket for everything. One clamp for mid or end. No tool splicing and bonding. Easy wire management. Simplicity UL 2703 listed LTR-AE-001-2012 listed Class A fire rating for any slope ASCE 7-16 PE Certified Code Compliant Secured on industry-leading Pegasus Mounts, for composite shingle and tile roofs. Backed by a 25-year warranty. Watertight for Life A Better Day on the Job Pegasus Solar Inc | 506 West Ohio Avenue, Richmond, CA 94804 | T: 510.210.3797 | www.pegasussolar.com A complete system for hassle-free rooftop installation, from watertight mounts to lifetime wire management. Next-Level Solar Mounting The N-S Bonding Jumper bonds row to row with no tools. Instant Bonding The Multi-Clamp works as mid- or end-clamp, and fits standard 30-40mm frames. One Clamp Anywhere Open rail channel holds and protects wires. Clamps won’t pinch wires after tightening. Lifetime Wire Management The narrowest panel gap available. Optional Hidden End Clamps and End Caps provide a flush look on the edge of the array. Premium Aesthetics Connect rails instantly, without tools, interference or limitations. Bonding Structural Splice Pegasus Max Rail Multi-Clamp Maximum-strength design. Meets specifications for high snow-load and hurricane zones. Black and Mill finish Fits 30-40mm PV frames, as mid- or end-clamp. Twist-locks into position; doesn’t pinch wires in rail. Bonds modules to rail; UL2703 listed as reusable Installs by hand. Works over mounts. Structurally connects and bonds rails automatically; UL2703 listed as reusable. Dovetail shape for extra strength. Uses ½” socket. Pegasus Rail Available in 14’ and 7’ lengths for easy layout and shipping. Open-channel design holds MC4 connectors, PV wire and trunk cables. Black and Mill finish RAIL SYSTEM Pegasus Solar Inc | 506 West Ohio Avenue, Richmond, CA 94804 | T: 510.210.3797 | www.pegasussolar.com Patents pending. All rights reserved. ©2021 Pegasus Solar Inc. Dovetail T-bolt Splice and Max Splice Ground Lug Offers premium edge appearance. Preinstalled pull-tab grips rail edge, allowing easy, one-hand installation. Tucks away for reuse. Hidden End Clamp Holds 6 or 8 AWG wire. Mounts on top or side of rail. Assembled on MLPE Mount. UL2703 listed as reusable. Hand operable. Holds wires in channel. Won’t slip. Secures four PV wires or two trunk cables. Stainless-steel backing provides durable grip. Eliminates sagging wires. Fits flush to PV module and hides raw or angled cuts. Hidden drain quickly clears water from rail. Secures and bonds most micro-inverters and optimizers to rail. Connectors and wires easily route underneath after installation. UL2703 listed as reusable. End Cap and Max End CapMLPE Mount Cable Grip Wire Clip Installs by hand, eliminates row-to-row copper wire. UL2703 listed as reusable only with Pegasus Rail. N-S Bonding Jumper Quickly calculate the most efficient layout, spans and materials needed to suit your job. Visit the Pegasus Customer Portal. pegasussolar.com/portal Certifications: • UL 2703, Edition 1 • LTR-AE-001-2012 • ASCE 7-16 PE certified • Class A fire rating for any slope roof FREEPEGASUS SOLARDesign Tool For reference only. Spans above are calculated using ASCE 7-16 for a Gable Roof, Exposure Category B, 7-20deg roof angle, 30ft mean roof height with non-exposed modules. For PE certified span tables, visit www.pegasussolar.com/spans. BLACK LOW PROFILE L-FOOT FOR QB2 FOR ASPHALT, EPDM, & TPO ROOFS PATENT # 8448407 17861 AHJ CONDENSED PERMIT PACKAGE 2020 Version 1 A DIVISION OF QUICKSCREWS INTERNATIONAL CORP TABLE OF CONTENTS 3 SPEC SHEET QTY & MEASUREMENT INFORMATION 5 INSTALLATION INSTRUCTIONS STEP-BY-STEP-INSTALLATION GUIDE Quickscrews International Corp. has changed the name of its solar division from SolarRoofHook to QuickBOLT TABLE OF CONTENTS 5830 Las Positas Road, Livermore CA 94551 | 3948 Airway Drive, Rock Hill SC 29732 Phone: (844) 671-6045 | Fax: (800) 689-7975 | www.quickbolt.com QuickBOLT is a division of Quickscrews International Corp.3 Part #Box Quantity 17861 Low Profile Black L-Foot (25) SPEC SHEET 5830 Las Positas Road, Livermore CA 94551 | 3948 Airway Drive, Rock Hill SC 29732 Phone: (844) 671-6045 | Fax: (800) 689-7975 | www.quickbolt.com QuickBOLT is a division of Quickscrews International Corp.4 PN# 17861 Black L-Foot for QB2 5830 Las Positas Road, Livermore CA 94551 | 3948 Airway Drive, Rock Hill SC 29732 Phone: (844) 671-6045 | Fax: (800) 689-7975 | www.quickbolt.com QuickBOLT is a division of Quickscrews International Corp.5 INSTALL INSTRUCTIONS BLACK QB2 (17862) RECOMMENDED MATERIALS • Tools to locate and mark rafter • Drill with a 15/64” drill bit • MFG approved sealant (optional) • 1/2” Nut Setter INSTALLATION INSTRUCTIONS 1. Locate and mark the rafter 2. Predrill the hole 3. Optional: Fill the predrilled hole with MFG approved sealant 4. Optional: Place a ring of sealant around the bottom of the Microflashing® washer 5. Place the Microflashing® 6. Insert the Bolt into the L-Foot 7. Drive the Bolt until the Microflashing® is compressed 1 2 3 5 6 7 4 2XWGRRU3KRWRYROWDLF(QFORVXUHV6HULHV (7/OLVWHGDQGODEHOHG 5HSRUW357-5HYLVHG0D\ · 8/7\SH5(GLWLRQ(OHFWULFDOHTXLSPHQWHQFORVXUHV · &6$&1R1HPD7\SH5 · &RQIRUPVWR8/6WDQGDUG · 9'&DPSV · 9$&DPSV · \HDUOLPLWHGZDUUDQW\ &RPSRVLWLRQ&HGDU5RRI6\VWHP %DVLF6SHFLILFDWLRQV 0DWHULDORSWLRQV · 3RZGHUFRDWHGJDXJHJDOYDQL]HGVWHHO KRXUVVDOWVSUD\ · 6WDLQOHVVVWHHO 3URFHVV-6HDPOHVVGUDZVWDPSHG )ODVKLQJ-´[´ +HLJKW-´ &DYLW\-&XELFLQFKHV $SSUR[LPDWHZHLJKW-OE %DVH3ODWH · )DVWHQHGWREDVHXVLQJWRJJOHIDVWHQLQJV\VWHP · URRIGHFNNQRFNRXWV · .QRFNRXWVL]HV´´DQG´ · ´PPVORWWHGGLQUDLO · *URXQG%ORFN DŽĚĞůƐĂǀĂŝůĂďůĞŝŶ'ƌĞLJ͕ůĂĐŬŽƌ^ƚĂŝŶůĞƐƐ^ƚĞĞů ^ŽůĂĞĐŬϬϳϵϵ-Ϯ^ ^ŽůĂĞĐŬϬϳϵϵ-' 3DVVWKURXJKDQGFRPELQHUNLWVDUHDYDLODEOHIRUHLWKHU $&RU'&DSSOLFDWLRQV ^ŽůĂĞĐŬϬϳϵϵ-ϱ' Ϭϳϵϵ^ĞƌŝĞƐDŽĚĞůƐ 'ƌŽƵŶĚdLJƉĞ 'ƌŽƵŶĚtŝƌĞ^ŝnjĞ Ϭϳϵϵ-Ϯ ϮWŽƐŝƟŽŶ'ƌŽƵŶĚ ϮͬϬ-ϭϰ Ϭϳϵϵ-ϱ ϱWŽƐŝƟŽŶ'ƌŽƵŶĚ ϭϰ-ϲ Ϭϳϵϵ- ƵĂů'ƌŽƵŶĚ ϭϰ-ϴ 567&(QWHUSULVHV,QF -- ƐĂůĞƐΛƐŽůĂĚĞĐŬ͘ĐŽŵ ǁǁǁ͘ƌƐƚĐĞŶƚĞƌƉƌŝƐĞƐ͘ĐŽŵ PLACARDS & STICKERS