Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED STRUCTURAL CALCS - 22-00602 - 576 S 4th E - Solar Panels
Author Name Author Email Author Phone No.: Larry Beesley Larry.Beesley@rexburg.org 208-372-2176 Description : 576 S 4th E - Solar Panels Address : 576 S 4th E Record Type : Solar Panels Document Filename : 6509-94352-154866-10723-StampedReviewletterandStructuralCalculations.pdf Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Approved # 22-00602 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments Pg 1 Stamp Larry Beesley : Building Open 1 Approved - Building Inspector Pg 2 Stamp Larry Beesley : Building Open 2 Approved - Building Inspector PV-2 SITE PLAN Stamp Larry Beesley : Building Open 4 Approved - Building Inspector Pg 14 Stamp Larry Beesley : Building Open 14 Approved - Building Inspector Pg 18 Stamp Larry Beesley : Building Open 18 Approved - Building Inspector Pg 19 Stamp Larry Beesley : Building Open 19 Approved - Building Inspector Pg 20 Stamp Larry Beesley : Building Open 20 Approved - Building Inspector Solar Panels Approval of plans does not constitute approval of variance from code Powered by TCPDF (www.tcpdf.org) 76 North Meadowbrook Drive Scott E. Wyssling, PE Alpine, UT 84004 Jon P. Ward, SE, PE office (201) 874-3483 Gregory T. Elvestad, PE swyssling@wysslingconsulting.com August 12, 2022 Current Insight 2852 W. Amini Way South Jordan, UT 84095 Re: Engineering Services Wolford Residence 576 S 4th East, Rexburg ID 7.055 kW System To Whom It May Concern: We have received information regarding solar panel installation on the roof of the above referenced structure. Our evaluation of the structure is to verify the existing capacity of the roof system and its ability to support the additional loads imposed by the proposed solar system. A. Site Assessment Information 1. Site visit documentation identifying attic information including size and spacing of framing for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information will be utilized for approval and construction of the proposed system. B. Description of Structure: Roof Framing: Prefabricated wood trusses at 24” on center. All truss members are constructed of 2x4 dimensional lumber. Roof Material: Composite Asphalt Shingles Roof Slope: 30 degrees Attic Access: Accessible Foundation: Permanent C. Loading Criteria Used • Dead Load o Existing Roofing and framing = 7 psf o New Solar Panels and Racking = 3 psf o TOTAL = 10 PSF • Dead Load o Existing Roofing and framing = 7 psf o New Solar Panels and Racking = 3 psf o TOTAL = 10 psf • Live Load = 20 psf (reducible) – 0 psf at locations of solar panels • Ground Snow Load = 50 psf • Wind Load based on ASCE 7-16 o Ultimate Wind Speed = 115 mph (based on Risk Category II) o Exposure Category C Analysis performed of the existing roof structure utilizing the above loading criteria is in accordance with the 2018 IRC, including provisions allowing existing structures to not require strengthening if the new loads do not exceed existing design loads by 105% for gravity elements and 110% for seismic elements. This analysis indicates that the existing framing will support the additional panel loading without damage, if installed correctly. Page 2 of 2 D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent Ironridge installation manual. If during solar panel installation, the roof framing members appear unstable or deflect non- uniformly, our office should be notified before proceeding with the installation. 2. The maximum allowable withdrawal force for a 5/16” lag screw is 235 lbs per inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications. Based on a minimum penetration depth of 2½”, the allowable capacity per connection is greater than the design withdrawal force (demand). Considering the variable factors for the existing roof framing and installation tolerances, the connection using one 5/16” diameter lag screw with a minimum of 2½” embedment will be adequate and will include a sufficient factor of safety. 3. Considering the wind speed, roof slopes, size and spacing of framing members, and condition of the roof, the panel supports shall be placed no greater than 72” on centers. 4. Panel supports connections shall be staggered to distribute load to adjacent framing members. Based on the above evaluation, this office certifies that with the racking and mounting specified, the existing roof system will adequately support the additional loading imposed by the solar system. This evaluation is in conformance with the 2018 IRC, current industry standards, and is based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. Very truly yours, Scott E. Wyssling, PE Idaho License No. 18974 COA # 4347 signed 08-12-22 s i g n e d 0 8 - 1 2 - 2 2 C O N T R A C T O R I N F O R M A T I O N 3 1 5 3 E 1 7 T H S T . A M M O N I D . 8 3 4 0 6 ( 2 0 8 ) - 7 0 9 - 7 2 0 7 C L I E N T I N F O R M A T I O N P R O J E C T D E T A I L S A P P L I C A B L E C O D E S SHEET INDEX A L L W O R K T O C O M P L Y W I T H T H E F O L L O W I N G C O D E : PV-1 PROJECT SUMMARYPV-2 SITE PLANPV-3 SINGLE LINE DIAGRAMAPPENDIX: - ELECTRICAL CALCULAT I O N S - PANEL CUT SHEET - OPTIMIZER CUT SHEET - INVERTER CUT SHEET - RACKING CUT SHEET - MOUNTING CUT SHEET - ADDITIONAL CUT SHEE T S - PLACARDS & STICKERS V I C I N I T Y M A P ALL CONDUIT TO RUN ON EXTERIOR O F H O U S E U N L E S S O T H E R W I S E N O T E D OCCUPANCY: R-3CONSTRUCTION TYPE: V-BUNSPRINKLERED1.ALL MODULES WILL BE GROUNDE D I N A C C O R D A N C E W I T H T H E C O D E A N D T H E MANUFACTURES INSTALLATION I N S T R U C T I O N S . 2.ALL PLACARDS REQUIRED BY NEC 2 0 1 7 C O D E M A C H I N E P R I N T E D L E T T E R S I N A C O N T R A S T I N G COLOR TO THE PLACARD.3.LIQUID TIGHT FLEXIBLE CONDUIT S H A L L B E S U N L I G H T R E S I S T A N T . 4.ELECTRICAL INSTALLATION WILL C O M P L Y W I T H N E C 2 0 1 7 C O D E . 5.ALL SOLAR MODULES EQUIPMEN T A N D M E T A L L I C C O M P O N E N T S A R E T O B E B O N D E D . 6.ALL PLUMBING AND MECHANICA L R O O F V E N T S T O C L E A R F R O M P H O T O V O L T A I C A R R A Y , O R EXTEND ABOVE SOLAR PANELS.7.SOLAR PHOTOVOLTAIC SYSTEM T O B E I N S T A L L E D O N R E S I D E N T I A L S T R U C T U R E . 8.DESIGN COMPLYING WITH THE IB C 2 0 1 8 C O D E A N D A L L L O C A L O R D I N A N C E S A N D P O L I C I E S . 9.THE PROJECT HAS BEEN DESIGNE D T O W I T H S T A N D A M I N I M U M 1 1 0 M P H W I N D L O A D . 10.THE SYSTEM WILL NOT BE INTERC O N N E C T E D U N T I L A P P R O V A L F R O M T H E L O C A L JURISDICTION AND A UTILITY IS O B T A I N E D . 11.IF THE MAIN SERVICE PANEL DOE S N O T H A V E V E R I F I A B L E G R O U N D I N G E L E C T R O D E , I T I S T H E CONTRACTORS RESPONSIBILITY T O I N S T A L L S U P P L E M E N T A L G R O U N D I N G E L E C T R O D E . 12.EACH MODULE WILL BE GROUND E D U S I N G T H E S U P P L I E D C O N N E C T I O N P O I N T S I D E N T I F I E D ON THE MODULE AND THE MAN U F A C T U R E R S I N S T A L L A T I O N I N S T R U C T I O N S . 13.A LADDER SHALL BE IN PLACE FO R I N S P E C T I O N I N C O M P L I A N C E W I T H O S H A R E G U L A T I O N S . 14.PROPER ACCESS AND WORKING C L E A R A N C E W I L L B E P R O V I D E D " W A R N I N G : P V P O W E R SOURCE" TO BE PLACED EVERY 1 0 F T . 15.GFCI PROTECTION IN INVERTER. N T S P V - 1 8 / 9 / 2 2 A M R R - 0 A N D R E W W O L F O R D 5 7 6 S 4 T H E ( 2 0 8 ) 7 0 9 - 9 7 6 1 R E X B U R G , I D 8 3 4 4 0 1 7 - M I S S I O N M S E 4 1 5 S X 6 Z ( 4 1 5 W ) P H O T O V O L T A I C M O D U L E S 1 - S O L A R E D G E S E 7 6 0 0 H - U S ( 7 6 0 0 W ) I N V E R T E R S Y S T E M S I Z E : 7 . 0 5 5 K W D C N E C 2 0 1 7 C O D E I B C / I R C / I F C 2 0 1 8 C O D E C I T Y O F R E X B U R G MOUNTRAFTER4'4'MAXSPAN C O N T R A C T O R I N F O R M A T I O N 3 1 5 3 E 1 7 T H S T . A M M O N I D . 8 3 4 0 6 ( 2 0 8 ) - 7 0 9 - 7 2 0 7 C L I E N T I N F O R M A T I O N N T S P V - 2 8 / 9 / 2 2 A M R R - 0 A N D R E W W O L F O R D 5 7 6 S 4 T H E ( 2 0 8 ) 7 0 9 - 9 7 6 1 R E X B U R G , I D 8 3 4 4 0 AERIAL VIEWMOUNTING PATTER N ROOF DE S C R I P T I O N ROOFTYPE A R R A Y P I T C H A Z I M U T H #1SHINGLE 3 0 ° 1 8 0 ° T O T A L P A N E L S : 1 7 S Y S T E M S I Z E : 7 . 0 5 5 K W D R I V E W A Y S 4TH E R O O F # 1 E X T E R I O R M E T E R M A I N S E R V I C E P A N E L A C D I S C O N N E C T I N V E R T E R 1 8 " C L E A R A N C E 18" CLEARANCE 3 ' W A L K W A Y s i g n e d 0 8 - 1 2 - 2 2 A A A N G N G A A A 1 1 2 2 3 A C D I S C O N N E C T W I T H I N 3 ’ O F U T I L I T Y M E T E R B B B B B B D E E L E C T R I C A L E Q U I P M E N T C A L L O U T S 7,055W TOTAL SOLAR A R R A Y 17 MISSION MSE415SX6Z (415W) P A N E L S 2 STRINGS OF 8/9 MODULES CO N N E C T E D I N S E R I E S @ 7 . 6 I N V E R T E R WIRE AND CONDUIT C A L L O U T S S O L A D E C K M O D E L 0 7 8 3 - 4 1 J U N C T I O N B O X / R O O F P E N E T R A T I O N , 6 0 0 V 7 . 6 k W I N V E R T E R U N G R O U N D E D S O L A R E D G E S E 7 6 0 0 H - U S ( 2 4 0 V ) I N V E R T E R 2 4 0 V A C , 3 2 A , N E M A 3 R , U L L I S T E D , ( W / I N T E G R A T E D D C D I S C O N N E C T ) W I T H I N T E G R A T E D G F P , W / I N T E G R A T E D A F P (2) #10 AWG PV/RHW-2 IN F R E E A I R (1) #6 AWG BARE COPPE R G N D I N F R E E A I R (2) #10 AWG THWN-2(1) #10 AWG THWN-2 GND I N 3 / 4 " E M T / F M C (3) #6 AWG THWN-2(1) #10 AWG THWN-2 GND I N 3 / 4 " E M T S 4 4 0 O P T I M I Z E R O N E P E R P A N E L B I - D I R E C T I O N A L U T I L I T Y M E T E R A B C D 123 2 0 0 A ( E ) M A I N S E R V I C E P A N E L M I S S I O N M S E 4 1 5 S X 6 Z M O D U L E E A T O N S A F E T Y S W I T C H , # D G 2 2 2 N R B 2 5 0 V A C , 6 0 A , N E M A 3 R , F U S E D , U L , N E M A , C S A , N O M C E R T I F I E D W / 4 0 A F U S E S E F G 3 C C NN CONNECTION AT SECONDARYSERVICE LOCATIONGGFG40A200A C O N T R A C T O R I N F O R M A T I O N 3 1 5 3 E 1 7 T H S T . A M M O N I D . 8 3 4 0 6 ( 2 0 8 ) - 7 0 9 - 7 2 0 7 C L I E N T I N F O R M A T I O N N T S P V - 3 8 / 9 / 2 2 A M R R - 0 A N D R E W W O L F O R D 5 7 6 S 4 T H E ( 2 0 8 ) 7 0 9 - 9 7 6 1 R E X B U R G , I D 8 3 4 4 0 MODULE:MISSION MSE415SX6Z ( 4 1 5 W ) Voc= 48.91V Isc= 10 . 9 1 A Vmp= 40.09V Imp= 1 0 . 3 5 A Module Inverter AC 4 Brand: MISSION Brand: # of Total Mods 17 Model # MSE415SX6Z Model # # of Strings 2 Vmp 40.09 V 15,200 W Condctr. Size #10 Voc: 48.91 V 480 V Condctr. Type THWN-2 Imp: 10.35 A 7,600 W Condctr. Mtrl Cu Isc: 10.91 A 32 A Output Voltage 15,200 Tvoc: -0.28 V/°C Output Current 480 Tisc: 0.04 A/°C Icont 600 °C °F Max Output Mods 10200 0 32 OCP Size 40 40 104 Qty.Description Inv. Eff. Inv. Power A Module 1 17 Icont 600 Inverter 1 1 96.5 7600 30 Deg C Ampacity 30 Module 2 B Inverter 2 Icont 600 Module 3 Start Ampacity 30 Inverter 3 Temperature Derate 0.91 7600 Total System Pwr. Conduit Fill Derate 1 Derated Ampacity 27.3 String 1 String 2 String 3 DC 4 Total Inverter output AC1 C Module INV 1 INV 1 INV 1 INV 1 Icont 24.55 Icont 600 # of Modules 8 9 0 0 Voltage 480 Ampacity 30 Condctr. Size #10 #10 #10 #10 Conductor Size 6 D Condctr. Type THWN-2 THWN-2 THWN-2 THWN-2 Conductor Type thwn-2 Icont 600 Condctr. Mtrl Cu Cu Cu Cu Aluminum / Copper cu OCP Size 40 Vmp 321 361 0 0 Cond Temp Rating 90 EGC Size 10 Voc 391 440 0 0 A Imp 10.35 10.35 0 0 Icont * 1.25 = Amps 40 AC 4 Isc 10.91 10.91 0 0 21.82 OCP Size 40 Output Current 25 Icont=isc*1.25 13.6375 13.6375 0 0 42.864 B Voltage 240 Icont * 1.25 = Amps 40 Condctr. Size 6 A 30 deg C Ampacity 0.75 Condctr. Type THWN-2 Icont*1.25=amps 13.6375 13.6375 0 0 C Condctr. Material Cu 30 Deg C Ampacity 30 30 30 30 Icont (Amps) 32 Condctr. Temp. Rating 90 B Start Ampacity 75 A Icont String 10.91 10.91 0 0 Temp Derate 0.91 Icont 31.25 Start Ampacity 30 30 30 30 Conduit Fill Derate 1 OCP Size 40 Temperature Derate 0.75 0.75 0.75 0.75 Derated Ampacity B Conduit Fill Derate 1 1 1 1 D Icont 31.25 Derated Ampacity 22.5 22.5 22.5 22.5 Icont*1.25 = Amps 30 Deg. C Ampacity 75 C 30 deg C Ampacity 75 C Icont*1.25=amps 13.6375 13.6375 0 0 E Output Current 25 Ampacity 30 30 30 30 EGC/GEC + 10 Start Ampacity 75 D Temperature Derate 0.91 Icont*1.25=amps 13.6375 13.6375 0 0 Conduit Fill Derate 1 OCP Size 15 15 0 0 Derated Ampacity 68.25 D Icont 31.25 30 Deg. C Ampacity 75 E EGC/GEC =10 Branch Characteristics Inverter(s) Output MISSION MSE415SX6Z SOLAREDGE SE7600H String Characteristics DC Strings Electrical Properties System Properties Min. Ambient Temp: Max Ambient Temp: Max PV DC Cap Max DC V Cont AC Power to Grid Cont AC Current to Grid SE7600 SolarEdge ROJECTS True American Quality True American Brand Mission Solar Energy is headquartered in San Antonio, Texas where we manufacture our modules. We produce American, high-quality solar modules ensuring the highest-in-class power output and best-in-class reliability. Our product line is tailored for residential, commercial and utility applications. Every Mission Solar Energy solar module is certified and surpasses industry standard regulations, proving excellent performance over the long term. Demand the best. Demand Mission Solar Energy. UL 61730 / IEC 61215 / IEC 61730 / IEC 61701 CERTIFICƒTIONS If you have questions or concerns about certification of our products in your area, please contact Mission Solar Energy. OF U.S. AND NON-U.S. PARTS C-SA2-MKTG-0028 REV 4 03/18/2022 www.missionsolar.com | info@missionsolar.com Frƒme-to-Frƒme Wƒrrƒnty Degradation guaranteed not to exceed 2% in year one and 0.58% annually from years two to 30 with 84.08% capacity guaranteed in year 25. For more information, visit www.missionsolar.com/warranty Certified Reliability • Tested to UL 61730 & IEC Standards • PID resistant • Resistance to salt mist corrosion Advanced Technology • 6 Busbar • Passivated Emitter Rear Contact • Ideal for all applications Extreme Weather Resilience • Up to 5,400 Pa front load & 3,600 Pa back load • Tested load to UL 61730 • 40 mm frame BAA Compliant for Government Projects • Buy American Act • American Recovery & Reinvestment Act 415W Class leading power output -0 to +3% Positive Power Tolerance MSE PERC 72 Mission Solar Energy reserves the right to make specification changes without notice. C-SA2-MKTG-0028 REV 4 03/18/2022 www.missionsolar.com | info@missionsolar.com Class Leading 410-420W MSE PERC 72 bƒsic dimensions [UNITS: MM/IN] 2086 40 2086 1054 Ø5.5 469 1054 2086 77 %DFN9LHZ6LGH9LHZ)URQW9LHZ Ø7.0 0RXQWLQJ+ROH *URXQGLQJ+ROH[ 41.5 41.5 .28 3 .22 82.1 82.1 1.6 82.1 18.5 ELECTRICƒL SPECIFICƒTION PRODUCT TYPE MSExxxSX6Z (xxx = Pmax) Power Output Pmax Wp 410 415 420 Module Efficiency %18.6 18.9 19.1 Tolerance %0/+3 0/+3 0/+3 Short Circuit Current Isc A 10.85 10.91 10.97 Open Circuit Voltage Voc V 48.70 48.91 49.13 Rated Current Imp A 10.28 10.35 10.42 Rated Voltage Vmp V 39.88 40.09 40.29 Fuse Rating A 20 20 20 System Voltage V 1,500 1,500 1,500 TEMPERƒTURE COEFFICIENTS Normal Operating Cell Temperature (NOCT)44.69°C (±3.7%) Temperature Coefficient of Pmax -0.359%/°C Temperature Coefficient of Voc -0.261%/°C Temperature Coefficient of Isc 0.044%/°C OPERƒTING CONDITIONS Maximum System Voltage 1,500Vdc Operating Temperature Range -40°C (-40°F) to +85°C (185°F) Maximum Series Fuse Rating 20A Fire Safety Classification Type 1* Front & Back Load (UL Standard) 5400 Pa front and 3600 Pa back load Tested to UL 61730 Hail Safety Impact Velocity 25mm at 23 m/s MECHƒNICƒL DƒTƒ Solar Cells P-type mono-crystalline silicon Cell Orientation 72 cells (6x12) Module Dimension 2,086mm x 1,054mm x 40mm Weight 23.4 kg (51.6 lbs.) Front Glass 3.2mm, tempered, low-iron, anti-reflective Frame Anodized Encapsulant Ethylene vinyl acetate (EVA) Junction Box Protection class IP67 with 3 bypass-diodes Cable 1.2m, Wire 4mm2 (12AWG) Connector Staubli PV-KBT4/6II-UR and PV-KST4/6II-UR, MC4, Renhe 05-8 current-voltƒge curve MSE415SX6Z: 415WP, 72 CELL SOLAR MODULE Current-voltage characteristics with dependence on irradiance and module temperature Voltƒge (v) Cu r r e n t ( ƒ ) Shipping informƒtion Container Feet Ship To Pallet Panels 415 W Bin 53’Most States 28 728 302.12 kW Double Stack CA 25 650 269.75 kW PALLET [26 PANELS] Weight 1,450 lbs. (657 kg) Height 47.5 in (120.65 cm) Width 46 in (116.84 cm) Length83.75 in (212.72 cm) certificƒtions ƒnd tests IEC 61215, 61730, 61701 UL 61730 Mission Solar Energy 8303 S. New Braunfels Ave., San Antonio, Texas 78235 www.missionsolar.com | info@missionsolar.com FRONT VIEW SIDE VIEW REAR VIEW *Mission Solar Energy uses quality sourced materials that result in a Type 1 fire rating. Please note, the ‘Fire Class’ Rating is designated for the fully-installed PV system, which includes, but is not limited to, the module, the type of mounting used, pitch and roof composition. Power Optimizer For North America S440, S500 25 YEAR WARRANTY PV power optimization at the module level Specifically designed to work with SolarEdge residential inverters Faster installations with simplified cable management and easy assembly using a single bolt Detects abnormal PV connector behavior, preventing potential safety issues* Module-level voltage shutdown for installer and firefighter safety Superior efficiency (99.5%) Flexible system design for maximum space utilization Compatible with bifacial PV modules Meets NEC requirements for arc fault protection (AFCI) and Photovoltaic Rapid Shutdown System (PVRSS) Mitigates all types of module mismatch loss, from manufacturing tolerance to partial shading * Expected availability in 2022 solaredge.com P O W E R O P T I M I Z E R Power Optimizer For North America S440, S500 S440 S500 Unit INPUT Rated Input DC Power(1) 440 500 W Absolute Maximum Input Voltage (Voc) 60 Vdc MPPT Operating Range 8 - 60 Vdc Maximum Short Circuit Current (Isc) of Connected PV Module 14.5 15 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.6 % Overvoltage Category II OUTPUT DURING OPERATION Maximum Output Current 15 Adc Maximum Output Voltage 60 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer 1+/-0.1 Vdc STANDARD COMPLIANCE Photovoltaic Rapid Shutdown System NEC 2014, 2017 & 2020 EMC FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741 Material UL94 V-0, UV Resistant RoHS Yes Fire Safety VDE-AR-E 2100-712:2013-05 INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Dimensions (W x L x H) 129 x 153 x 30 / 5.07 x 6.02 x 1.18 mm / in Weight (including cables) 655 / 1.5 gr / lb Input Connector MC4(2) Input Wire Length 0.1 / 0.32 m / ft Output Connector MC4 Output Wire Length (+) 2.3, (-) 0.10 / (+) 7.54, (-) 0.32 m / ft Operating Temperature Range(3) -40 to +85 ˚C Protection Rating IP68 / Type6B Relative Humidity 0 - 100 % (1) Rated power of the module at STC will not exceed the power optimizer Rated Input DC Power. Modules with up to +5% power tolerance are allowed (2) For other connector types please contact SolarEdge (3) For ambient temperature above +70°C / +158°F power de-rating is applied. Refer to Power Optimizers Temperature De-Rating Technical Note for more details PV System Design Using a SolarEdge Inverter Single Phase HD-Wave Three Phase for 208V grid Three Phase for 277/480V grid Minimum String Length (Power Optimizers) S440, S500 8 14 18 Maximum String Length (Power Optimizers) 25 50(4) Maximum Nominal Power per String 5700 (6000 with SE7600-US-SE11400-U) 6000 12750 W Maximum Allowed Connected Power per String (5) (Permitted only when the difference in connected power between strings is 1,000W or less) Refer to Footnote 5 One String 7200W 15,000W Two strings or more 7800W Parallel Strings of Different Lengths or Orientations Y (4) A string with more than 30 optimizers does not meet NEC rapid shutdown requirements; safety voltage will be above the 30V requirement (5) If the inverters rated AC power ≤ maximum nominal power per string, then the maximum power per string will be able to reach up to the inverters maximum input DC power. Refer to: https://www.solaredge.com/ sites/default/files/se-power-optimizer-single-string-design-application-note.pdf (6) It is not allowed to mix S-series and P-series Power Optimizers in new installations © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or r egistered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: February 8, 2022 DS-000018-NA. Subject to change without notice. Single Phase Energy Hub Inverter with Prism Technology For North America SE3000H-US / SE3800H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US(1) 12-25 YEAR WARRANTY Optimized battery storage with HD-Wave technology Record-breaking 99% weighted efficiency with 200% DC oversizing Small, lightweight, and easy to install Modular design, future ready with optional upgrades to: DC-coupled storage for full or partial home backup Built-in consumption monitoring Direct connection to the SolarEdge smart EVcharger Multi-inverter, scalable storage solution With enhanced battery power up to 10kW Integrated arc fault protection and rapid shutdown for NEC 2014,NEC 2017 and NEC 2020,per article 690.11 and 690.12 Embedded revenue grade production data, ANSI C12.20 Class 0.5 solaredge.com H O M E B A C K U P Single Phase Energy Hub Inverter with Prism Technology For North America SE3000H-US / SE3800H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US(1) SE3000H-US SE3800H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US UNITS OUTPUT - AC ON GRID Rated AC Power 3000 3800 @ 240V 3300 @ 208V 6000 @ 240V 5000 @ 208V 7600 10000 11400 @ 240V 10000 @ 208V W Maximum AC Power Output 3000 3800 @ 240V 3300 @ 208V 6000 @ 240V 5000 @ 208V 7600 10000 11400 @ 240V 10000 @ 208V W AC Frequency Range (min - nom - max) 59.3 - 60 - 60.5(2)Hz Maximum Continuous Output Current @ 240V 12.5 16 25 32 42 47.5 A Maximum Continuous Output Current @ 208V - 16 24 - - 48.5 A GFDI Threshold 1 A Total Harmonic Distortion (THD) <3 % Power Factor 1, adjustable -0.85 to 0.85 Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes Charge Battery from AC (if allowed) Yes Typical Nighttime Power Consumption <2.5 W OUTPUT - AC BACKUP(3) Rated AC Power in Backup Operation(4) 3000 3800 6000 7600 10000 10300 W 7600* 10300* AC L-L Output Voltage Range in Backup 211 - 264 Vac AC L-N Output Voltage Range in Backup 105 - 132 Vac AC Frequency Range in Backup (min - nom - max) 55 - 60 - 65 Hz Maximum Continuous Output Current in Backup Operation 12.5 16 25 32 42 43 A 32* 43* GFDI 1 A THD <5 % OUTPUT - SMART EV CHARGER AC Rated AC Power 9600 W AC Output Voltage Range 211 - 264 Vac On-Grid AC Frequency Range (min - nom - max) 59.3 - 60 - 60.5 Hz Maximum Continuous Output Current @240V (grid, PV and battery) 40 Aac INPUT - DC (PV AND BATTERY) Transformer-less, Ungrounded Yes Max Input Voltage 480 Vdc Nom DC Input Voltage 380 Vdc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600kΩ Sensitivity INPUT - DC (PV) Maximum DC Power @ 240V 6000 7600 12000 15200 22000 22800 W 15200* 22800* Maximum DC Power @ 208V - 6600 10000 - - 20000 W Maximum Input Current(5) @ 240V 8.5 10.5 16.5 20 27 31 Adc 20* 31* Maximum Input Current(5) @ 208V - 9 13.5 - - 27 Adc Max. Input Short Circuit Current 45 Adc Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 99 @ 240V 98.5 @ 208V % 2-pole Disconnection Yes *Supported with PN SExxxxH-USMMxxxxxx or SExxxxH-USMNxxxxxx (1) These specifications apply to inverters with part numbers SExxxxH-USSMxxxxx or SExxxxH-USSNxxxxxx and connection unit model number DCD-1PH-US-PxH-F-x (2) For other regional settings please contact SolarEdge support (3) Not designed for standalone applications and requires AC for commissioning. Backup functionality is only supported for 240V grid(4) Rated AC power in Backup Operation are valid for installations with multiple inverters. For a single backup inverter operation, rated AC power in Backup is 90% of the value stated (5) A higher current source may be used; the inverter will limit its input current to the values stated Single Phase Energy Hub Inverter with Prism Technology For North America SE3000H-US / SE3800H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US(1) SE3000H-US SE3800H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US UNITS INPUT - DC (BATTERY) Supported Battery Types SolarEdge Energy Bank, LG RESU Prime(6) Number of Batteries per Inverter Up to 3 SolarEdge Energy Bank, up to 2 LG RESU Prime Continuous Power(7) 6000 7600 10000 W Peak Power(7) 6000 7600 10000 W Max Input Current 16 20 26.5 Adc 2-pole Disconnection Yes SMART ENERGY CAPABILITIES Consumption Metering Built - in(8) Backup & Battery Storage With Backup Interface (purchased separately) for service up to 200A; Up to 3 inverters EV Charging Direct connection to Smart EV charger ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, Cellular(9), Wi-Fi (optional),SolarEdge Energy Net (optional) Revenue Grade Metering, ANSI C12.20 Built - in(8) Integrated AC, DC and Communication Connection Unit Yes Inverter Commissioning With the SetApp mobile application using built-in Wi-Fi Access Point for local connection DC Voltage Rapid Shutdown (PV and Battery) Yes, according to NEC 2014, NEC 2017 and NEC 2020 690.12 STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1741 PCS, UL1699B, UL1998, UL9540, CSA 22.2 Grid Connection Standards IEEE1547, Rule 21, Rule 14H Emissions FCC part 15 class B INSTALLATION SPECIFICATIONS AC Output and EV AC Output Conduit Size / AWG Range 1'' maximum / 14-4 AWG DC Input (PV and Battery) Conduit Size / AWG Range 1'' maximum / 14-6 AWG Dimensions with Connection Unit (H x W x D) 17.7 x 14.6 x 6.8 / 450 x 370 x 174 17.7 x 14.6 x 6.8 / 450 x 370 x 174 17.7 x 14.6 x 6.8 / 450 x 370 x 174 in / mm 17.7 x 14.6 x 6.8 / 450 x 370 x 174* Weight with Connection Unit 26 / 11.8 26 / 11.8 30.2 / 13.7 lb / kg 30.2 / 13.7* Noise < 25 < 25 < 25 < 50 dBA < 50* Cooling Natural Convection Operating Temperature Range -40 to +140 / -40 to +60(10) ˚F / ˚C Protection Rating NEMA 4 (6)The part numbers SExxxxH-USxMxxxxx only support the SolarEdge Energy Bank. The part numbers SExxxxH-USxNxxxxx support both SolarEdge Energy Bank and LG RESU Prime batteries Requires supporting inverter firmware(7)Discharge power is limited up to the inverter rated AC power for on-grid and backup applications (8)For consumption metering current transformers should be ordered separately: SECT-SPL-225A-T-20 or SEACT0750-400NA-20 units per box. Revenue grade metering is only for production metering (9)Information concerning the Data Plan's terms & conditions is available in the following link: https://www.solaredge.com/sites/default/files/se-communication-plan-terms-and-conditions-eng.pdf (10)Full power up to at least 50°C / 122°F; for power de-rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners.Date:06/2021 DS-000031-1.5-NAM.Subject to change without notice. RAIL SYSTEM 1/2”socket for everything. One clamp for mid or end. No tool splicing and bonding. Easy wire management. Simplicity UL 2703 listed LTR-AE-001-2012 listed Class A fire rating for any slope ASCE 7-16 PE Certified Code Compliant Secured on industry-leading Pegasus Mounts, for composite shingle and tile roofs. Backed by a 25-year warranty. Watertight for Life A Better Day on the Job Pegasus Solar Inc | 506 West Ohio Avenue, Richmond, CA 94804 | T: 510.210.3797 | www.pegasussolar.com A complete system for hassle-free rooftop installation, from watertight mounts to lifetime wire management. Next-Level Solar Mounting The N-S Bonding Jumper bonds row to row with no tools. Instant Bonding The Multi-Clamp works as mid- or end-clamp, and fits standard 30-40mm frames. One Clamp Anywhere Open rail channel holds and protects wires. Clamps won’t pinch wires after tightening. Lifetime Wire Management The narrowest panel gap available. Optional Hidden End Clamps and End Caps provide a flush look on the edge of the array. Premium Aesthetics Connect rails instantly, without tools, interference or limitations. Bonding Structural Splice Pegasus Max Rail Multi-Clamp Maximum-strength design. Meets specifications for high snow-load and hurricane zones. Black and Mill finish Fits 30-40mm PV frames, as mid- or end-clamp. Twist-locks into position; doesn’t pinch wires in rail. Bonds modules to rail; UL2703 listed as reusable Installs by hand. Works over mounts. Structurally connects and bonds rails automatically; UL2703 listed as reusable. Dovetail shape for extra strength. Uses ½” socket. Pegasus Rail Available in 14’ and 7’ lengths for easy layout and shipping. Open-channel design holds MC4 connectors, PV wire and trunk cables. Black and Mill finish RAIL SYSTEM Pegasus Solar Inc | 506 West Ohio Avenue, Richmond, CA 94804 | T: 510.210.3797 | www.pegasussolar.com Patents pending. All rights reserved. ©2021 Pegasus Solar Inc. Dovetail T-bolt Splice and Max Splice Ground Lug Offers premium edge appearance. Preinstalled pull-tab grips rail edge, allowing easy, one-hand installation. Tucks away for reuse. Hidden End Clamp Holds 6 or 8 AWG wire. Mounts on top or side of rail. Assembled on MLPE Mount. UL2703 listed as reusable. Hand operable. Holds wires in channel. Won’t slip. Secures four PV wires or two trunk cables. Stainless-steel backing provides durable grip. Eliminates sagging wires. Fits flush to PV module and hides raw or angled cuts. Hidden drain quickly clears water from rail. Secures and bonds most micro-inverters and optimizers to rail. Connectors and wires easily route underneath after installation. UL2703 listed as reusable. End Cap and Max End CapMLPE Mount Cable Grip Wire Clip Installs by hand, eliminates row-to-row copper wire. UL2703 listed as reusable only with Pegasus Rail. N-S Bonding Jumper Quickly calculate the most efficient layout, spans and materials needed to suit your job. Visit the Pegasus Customer Portal. pegasussolar.com/portal Certifications: • UL 2703, Edition 1 • LTR-AE-001-2012 • ASCE 7-16 PE certified • Class A fire rating for any slope roof FREEPEGASUS SOLARDesign Tool For reference only. Spans above are calculated using ASCE 7-16 for a Gable Roof, Exposure Category B, 7-20deg roof angle, 30ft mean roof height with non-exposed modules. For PE certified span tables, visit www.pegasussolar.com/spans. BLACK LOW PROFILE L-FOOT FOR QB2 FOR ASPHALT, EPDM, & TPO ROOFS PATENT # 8448407 17861 AHJ CONDENSED PERMIT PACKAGE 2020 Version 1 A DIVISION OF QUICKSCREWS INTERNATIONAL CORP TABLE OF CONTENTS 3 SPEC SHEET QTY & MEASUREMENT INFORMATION 5 INSTALLATION INSTRUCTIONS STEP-BY-STEP-INSTALLATION GUIDE Quickscrews International Corp. has changed the name of its solar division from SolarRoofHook to QuickBOLT TABLE OF CONTENTS 5830 Las Positas Road, Livermore CA 94551 | 3948 Airway Drive, Rock Hill SC 29732 Phone: (844) 671-6045 | Fax: (800) 689-7975 | www.quickbolt.com QuickBOLT is a division of Quickscrews International Corp.3 Part #Box Quantity 17861 Low Profile Black L-Foot (25) SPEC SHEET 5830 Las Positas Road, Livermore CA 94551 | 3948 Airway Drive, Rock Hill SC 29732 Phone: (844) 671-6045 | Fax: (800) 689-7975 | www.quickbolt.com QuickBOLT is a division of Quickscrews International Corp.4 PN# 17861 Black L-Foot for QB2 5830 Las Positas Road, Livermore CA 94551 | 3948 Airway Drive, Rock Hill SC 29732 Phone: (844) 671-6045 | Fax: (800) 689-7975 | www.quickbolt.com QuickBOLT is a division of Quickscrews International Corp.5 INSTALL INSTRUCTIONS BLACK QB2 (17862) RECOMMENDED MATERIALS • Tools to locate and mark rafter • Drill with a 15/64” drill bit • MFG approved sealant (optional) • 1/2” Nut Setter INSTALLATION INSTRUCTIONS 1. Locate and mark the rafter 2. Predrill the hole 3. Optional: Fill the predrilled hole with MFG approved sealant 4. Optional: Place a ring of sealant around the bottom of the Microflashing® washer 5. Place the Microflashing® 6. Insert the Bolt into the L-Foot 7. Drive the Bolt until the Microflashing® is compressed 1 2 3 5 6 7 4 2XWGRRU3KRWRYROWDLF(QFORVXUHV6HULHV (7/OLVWHGDQGODEHOHG 5HSRUW357-5HYLVHG0D\ · 8/7\SH5(GLWLRQ(OHFWULFDOHTXLSPHQWHQFORVXUHV · &6$&1R1HPD7\SH5 · &RQIRUPVWR8/6WDQGDUG · 9'&DPSV · 9$&DPSV · \HDUOLPLWHGZDUUDQW\ &RPSRVLWLRQ&HGDU5RRI6\VWHP %DVLF6SHFLILFDWLRQV 0DWHULDORSWLRQV · 3RZGHUFRDWHGJDXJHJDOYDQL]HGVWHHO KRXUVVDOWVSUD\ · 6WDLQOHVVVWHHO 3URFHVV-6HDPOHVVGUDZVWDPSHG )ODVKLQJ-´[´ +HLJKW-´ &DYLW\-&XELFLQFKHV $SSUR[LPDWHZHLJKW-OE %DVH3ODWH · )DVWHQHGWREDVHXVLQJWRJJOHIDVWHQLQJV\VWHP · URRIGHFNNQRFNRXWV · .QRFNRXWVL]HV´´DQG´ · ´PPVORWWHGGLQUDLO · *URXQG%ORFN DŽĚĞůƐĂǀĂŝůĂďůĞŝŶ'ƌĞLJ͕ůĂĐŬŽƌ^ƚĂŝŶůĞƐƐ^ƚĞĞů ^ŽůĂĞĐŬϬϳϵϵ-Ϯ^ ^ŽůĂĞĐŬϬϳϵϵ-' 3DVVWKURXJKDQGFRPELQHUNLWVDUHDYDLODEOHIRUHLWKHU $&RU'&DSSOLFDWLRQV ^ŽůĂĞĐŬϬϳϵϵ-ϱ' Ϭϳϵϵ^ĞƌŝĞƐDŽĚĞůƐ 'ƌŽƵŶĚdLJƉĞ 'ƌŽƵŶĚtŝƌĞ^ŝnjĞ Ϭϳϵϵ-Ϯ ϮWŽƐŝƟŽŶ'ƌŽƵŶĚ ϮͬϬ-ϭϰ Ϭϳϵϵ-ϱ ϱWŽƐŝƟŽŶ'ƌŽƵŶĚ ϭϰ-ϲ Ϭϳϵϵ- ƵĂů'ƌŽƵŶĚ ϭϰ-ϴ 567&(QWHUSULVHV,QF -- ƐĂůĞƐΛƐŽůĂĚĞĐŬ͘ĐŽŵ ǁǁǁ͘ƌƐƚĐĞŶƚĞƌƉƌŝƐĞƐ͘ĐŽŵ PLACARDS & STICKERS