Loading...
HomeMy WebLinkAboutREDLINED PLANS TALL - 22-00066 - Elite Storage Bldg 6Author Name Author Email Author Phone No.: Alex Owens Alex.Owens@rexburg.org 208-372-2330 Cody Jones Cody.Jones@rexburg.org 208-372-2173 Description : Elite Storage Bldg 6 Address : 1044 N 2nd E Application Type : Document Filename : Porter RV Storage (Tall) 12-20-21.pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments G-101 Free text Cody Jones : Building Open 1 roof load, 50 psf ground snow load. S-101 Free text Cody Jones : Building Open 4 All wood in contact with concrete needs to be pressure treated. S-101 Free text Cody Jones : Building Open 4 6 S-101 Free text Cody Jones : Building Open 4 City ordinance calls for top horizontal to be placed in top 6". S-101 Free text Cody Jones : Building Open 4 City ordinance calls for all footings to have a minimum 2 #4 bars continuous. S-301 Free text Cody Jones : Building Open 5 Need engineered truss plans. R-101 Free text Cody Jones : Building Open 6 36" G-101 Free text Alex Owens : Electrical Open 1 Please send in electrical plans or have electrical contractor contact me to verify wiring methods will be in accordance with 2017 NEC. # 22-00066 New Commercial Building Report Date: 02.10.2022 Approval of plans does not constitute approval of variance from code Page 1 of 1 Powered by TCPDF (www.tcpdf.org) INDEX OF SHEETS G-101 A-101 A-201 S-101 S-301 R-101 COVER SHEET MAIN FLOOR ELEVATIONS FOUNDATION ROOF FRAMING DETAILS UNFINISHED SQUARE FOOTAGEUNFINISHED SQUARE FOOTAGEUNFINISHED SQUARE FOOTAGEUNFINISHED SQUARE FOOTAGE ID Storage AREA 9,000.00 9,000.00 sq ft LOCATION: REXBURG SNOW LOAD: 35 PSF WIND SPEED: 115 MPH FROST DEPTH: 36 IN SEISMIC: D REGULATION: 2018 IBC RISK CATEGORY: I OCCUPANCY: S-1 CONSTRUCTION TYPE: VB ALLOWABLE AREA NS: 9000+4500 (PER 506.2.1) PORTER RV STORAGEPORTER RV STORAGEPORTER RV STORAGEPORTER RV STORAGE 14' X 30' UNITS DR A W N B Y : CH K ' D B Y : BH A W B S PL O T D A T E : 12 / 2 0 / 2 0 2 1 EN G I N E E R : R A Y M C D O U G A L , P E DE S C R I P T I O N RE V I S I O N D A T E CO V E R S H E E T SH E E T T I T L E : SHEET 1 G-101 10 6 6 N o r t h Y e l l o w s t o n e H w y Re x b u r g , I D 8 3 4 4 0 ww w . s o u t h f o r k e n g i n e e r i n g . c o m 20 8 - 8 5 2 - 6 2 3 6 So u t h F o r k D e s i g n G r o u p , L L C Co p y r i g h t 2 0 1 6 | S o u t h f o r k E n g i n e e r i n g | A l l R i g h t s R e s e r v e d . PO R T E R R V 10 5 0 N O R T H 2 N D E A S T RE X B U R G , I D 12/20/2021 Please send in electrical plans or have electrical contractor contact me to verify wiring methods will be in accordance with 2017 NEC. roof load, 50 psf ground snow load. 1111111111 1111111111 15'-10"14'-10 1/2"14'-101/2"14'-10 1/2"14'-101/2"14'-10 1/2"14'-101/2"14'-10 1/2"14'-101/2"15'-2" 150' 150' 8'15'-5"14'-101/2"14'-10 1/2"14'-101/2"14'-10 1/2"14'-101/2"14'-10 1/2"14'-101/2"14'-10 1/2"7'-7" 60 ' 30 ' 30 ' 44'-111/2" 3 A- 2 0 1 3 A- 2 0 1 6X6 w/ BC6 POST CAP 6-3/4X13-1/2 24F-V4 GLULAM BW P 1 BW P 1 BW P 1 BW P 1 1/2" REDHEAD ANCHORS 6' O.C. ALL INTERIOR WALLS (TYP) 6X6 w/ BC6 POST CAP 6X6 w/ BC6 POST CAP 6X6 w/ BC6 POST CAP BW P 1 BW P 1 BW P 1 BW P 1 BW P 1 BW P 1 BW P 1 BW P 1 BW P 1 BW P 1 BW P 1 BW P 1 BW P 1 BW P 1 BW P 1 BW P 1 BW P 1 BW P 1 BW P 1 BW P 1 BW P 1 BW P 1 BW P 1 BW P 1 BW P 1 BW P 1 BW P 1 BW P 1 BW P 1 BW P 1 BW P 1 BW P 1 ENTIRE WALL LENGTH TO BE BWP1 BW P 1 BW P 1 BW P 1 BW P 1 BWP1BWP1BWP1BWP1 BWP1BWP1BWP1BWP1 BWP1BWP1BWP1BWP1 BRACE WALL SCHEDULE : ALL EXTERIOR WALLS BWP1 U.N.O.BRACE WALL SCHEDULE : ALL EXTERIOR WALLS BWP1 U.N.O.BRACE WALL SCHEDULE : ALL EXTERIOR WALLS BWP1 U.N.O.BRACE WALL SCHEDULE : ALL EXTERIOR WALLS BWP1 U.N.O. IDIDIDID BWP1 LOCATIONLOCATIONLOCATIONLOCATION EXTERIOR STUDSSTUDSSTUDSSTUDS 2X4 O.C.O.C.O.C.O.C. 16" SHEATINGSHEATINGSHEATINGSHEATING 7/16" OSB FASTENINGFASTENINGFASTENINGFASTENING 8d NAILS EDGESEDGESEDGESEDGES 4" O.C. FIELDFIELDFIELDFIELD 8" O.C. NOTESNOTESNOTESNOTES DOOR SCHEDULEDOOR SCHEDULEDOOR SCHEDULEDOOR SCHEDULE ID 1 QTY 20 LOCATION Exterior FIRE RATING DOOR W 12' HT 14' NOTES HEADER: 3-1/8X10-1/2 GLULAM 5 STORAGE UNITSSTORAGE UNITSSTORAGE UNITSSTORAGE UNITS SCALE: SCALE: SCALE: SCALE: 3/16" = 1'-0"3/16" = 1'-0"3/16" = 1'-0"3/16" = 1'-0" GENERAL FRAMING NOTE:GENERAL FRAMING NOTE:GENERAL FRAMING NOTE:GENERAL FRAMING NOTE: 1. EXTERIOR WALL FRAMING SHALL BE CONVENTIONAL 2x4 FRAMING @ 16" O.C. U.N.O. 2. IF LUMBER GRADING IS NOT SPECIFIED, ASSUME SPF#2 OR BETTER. 3. SEE SHEAR OR BRACE WALL PANEL SCHEDULE FOR WALL SHEATHING AND FASTENING. 4. ENSURE THAT WALLS TALLER THAN 10' HAVE BLOCKING @ PANEL EDGES AND FIRE BLOCKING. 5. ENSURE THAT INTERIOR BEARING WALLS ARE SUPPORTED IN FLOOR BY BLOCKING OR DOUBLE JOISTS. 6. ENSURE THAT COLUMNS INDICATED ON MAIN OR UPPER FLOORS ARE DIRECTLY SUPPORT BY BEAMS OR COLUMNS IN L OWER FLOORS OR SOLID BLOCKING. PROVIDE POSITIVE CONNECTIONS BETWEEN UPPER AND LOWER. 7. INSTALL ALL HANGERS, HOLD DOWNS, TIES, AND ANCHORS & CAPS AS SPECIFIED IN MANUFACTURER DOCUMENTATION. 8. ENSURE THAT WINDOWS & DOORS ARE FLASHED AND SEALED OVER AN APPROVED WALL/ROOFING MEMBRANE TO ENSURE MOISTURE PROTECTION 9. INSTALL SIDING PER MANUFACTURER REQ., INCLUDING RAIN SCREEN OR OTHER. 10. ALL STAIRS SHALL BE CONVENTIONAL IN CONSTRUCTION WITH A MAX RISE OF 7 3/4" AND A MINIMUM RUN OF 10". 11. PROVIDE GUARD RAILS @ 36" FROM NOSING, AND HANDRAILS AT THE SAME. 12. ENSURE TIMBER CONNECTIONS ARE ADEQUATELY SUPPORT AND BRACED WHERE THEY CONNECT TO THE LIGHT FRAME STRUCTURE. DR A W N B Y : CH K ' D B Y : BH A W B S PL O T D A T E : 12 / 2 0 / 2 0 2 1 EN G I N E E R : R A Y M C D O U G A L , P E DE S C R I P T I O N RE V I S I O N D A T E MA I N F L O O R SH E E T T I T L E : SHEET 2 A-101 10 6 6 N o r t h Y e l l o w s t o n e H w y Re x b u r g , I D 8 3 4 4 0 ww w . s o u t h f o r k e n g i n e e r i n g . c o m 20 8 - 8 5 2 - 6 2 3 6 So u t h F o r k D e s i g n G r o u p , L L C Co p y r i g h t 2 0 1 6 | S o u t h f o r k E n g i n e e r i n g | A l l R i g h t s R e s e r v e d . PO R T E R R V 10 5 0 N O R T H 2 N D E A S T RE X B U R G , I D 12/20/2021 -2'-4" TOP OF FOOTER 0" GRADE 15'-4" TOP PLATE -2'-4" TOP OF FOOTER 0" GRADE 15'-4" TOP PLATE 23'-6 3/4" OVERALL HEIGHT 3 12 312 6-3/4X13-1/2 GLULAM TRU SSES PER MANUFACTURER 1 FRONT ELEVATIONFRONT ELEVATIONFRONT ELEVATIONFRONT ELEVATION SCALE: SCALE: SCALE: SCALE: 3/16" = 1'-0"3/16" = 1'-0"3/16" = 1'-0"3/16" = 1'-0" 2 LEFT ELEVATIONLEFT ELEVATIONLEFT ELEVATIONLEFT ELEVATION SCALE: SCALE: SCALE: SCALE: 1/4" = 1'-0"1/4" = 1'-0"1/4" = 1'-0"1/4" = 1'-0" 3 SECTIONSECTIONSECTIONSECTION SCALE: SCALE: SCALE: SCALE: 1/4" = 1'-0"1/4" = 1'-0"1/4" = 1'-0"1/4" = 1'-0" DR A W N B Y : CH K ' D B Y : BH A W B S PL O T D A T E : 12 / 2 0 / 2 0 2 1 EN G I N E E R : R A Y M C D O U G A L , P E DE S C R I P T I O N RE V I S I O N D A T E EL E V A T I O N S SH E E T T I T L E : SHEET 3 A-201 10 6 6 N o r t h Y e l l o w s t o n e H w y Re x b u r g , I D 8 3 4 4 0 ww w . s o u t h f o r k e n g i n e e r i n g . c o m 20 8 - 8 5 2 - 6 2 3 6 So u t h F o r k D e s i g n G r o u p , L L C Co p y r i g h t 2 0 1 6 | S o u t h f o r k E n g i n e e r i n g | A l l R i g h t s R e s e r v e d . PO R T E R R V 10 5 0 N O R T H 2 N D E A S T RE X B U R G , I D 12/20/2021 60 ' 30 ' 30 ' 150' 30'-10 1/4"29'-9"29'-9"29'-9"29'-10 3/4" 14'-53/4"14'-91/4"14'-10 1/2"14'-6 1/4"3"3" 1 1 1 1 111 111 F2F2F2F2 F2F2F2F2 F2F2F2F2 F2F2F2F2 F1F1F1F1 F1F1F1F1 F1F1F1F1F1F1F1F1F2F2F2F2 F2F2F2F2 F2F2F2F2 F2F2F2F2 F2F2F2F2 F2F2F2F2 ABU66Z ABU66Z 6" FOUNDATION WALL, 28" TALL, #4 BAR BOTH WAYS @ 24" O.C. (TYP) F2F2F2F2 F2F2F2F2 ABU66Z ABU66Z 1 1 SLAB ON GRADE F2 - THICKEND SLAB FOOTINGS 12"X8" WITH (2) #3 BARS 3 A- 2 0 1 3 A- 2 0 1 FOOTING SCHEDULEFOOTING SCHEDULEFOOTING SCHEDULEFOOTING SCHEDULE IDIDIDID F1 F2 DEPTHDEPTHDEPTHDEPTH 8" 8" WIDTHWIDTHWIDTHWIDTH 16" 12" TYPETYPETYPETYPE CONT CONT # OF BARS# OF BARS# OF BARS# OF BARS (2) (2) BAR SIZEBAR SIZEBAR SIZEBAR SIZE #4 #3 PIER (IF REQUIRED)PIER (IF REQUIRED)PIER (IF REQUIRED)PIER (IF REQUIRED) --- --- SIMPSON TIESSIMPSON TIESSIMPSON TIESSIMPSON TIES SYMSYMSYMSYM IDIDIDID 1 QTY.QTY.QTY.QTY. 12 TYPETYPETYPETYPE HDU5 FASTENERS 1/2" REDHEAD ANCHORS 3 FOUNDATION PLANFOUNDATION PLANFOUNDATION PLANFOUNDATION PLAN SCALE: SCALE: SCALE: SCALE: 3/16" = 1'-0"3/16" = 1'-0"3/16" = 1'-0"3/16" = 1'-0" FOUNDATION NOTE:FOUNDATION NOTE:FOUNDATION NOTE:FOUNDATION NOTE: 1. 6" FOUNDATION WALL W/#4 BAR VERT @ 48" O.C. & #4 BAR HORIZ. @ 24" O.C. W/(1) BAR IN TOP 12" OF WALL. 2. SEE FOOTING SCHEDULE FOR FOOTING SIZE AND REBAR PLACEMENT. ALL FOOTINGS TO BEAR ON APPROVED STRUCTURAL FILL OR UNDISTURBED SOIL. VERTICAL REBAR TO TURN HORIZONTALLY INTO SLAB. 3. FOOTING DESIGN IS BASED ON SOIL LOAD-BEARING CAPACITY OF 1500 PSF. IF CONTRACTORS ENCOUNTER EXPANSIVE SOILS OR OTHER PROBLEMS, THE SITE MUST BE APPROVED BY A SOILS ENGINEER PRIOR TO POURING FOOTINGS IN THAT AREA. 4. CONCRETE FOR FOOTINGS AND FOUNDATION WALLS TO HAVE A 28 DAY COMPRESSIVE STRENGTH OF 3000 PSI. 2500 PSI USED IN DESIGN, THEREFORE NO SPECIAL INSPECTIONS. 5. TYPICAL ANCHOR BOLTS TO BE MIN 1/2" X 7" REDHEAD TRUBOLT @ 48" O.C. ENTIRE WALL PERIMETER AND FOOTERS THAT SUPPORT FRAME STEM WALLS. 6. LAP REBAR SPLICES 30 BAR DIAMETERS U.N.O. 7. REINFORCING STEEL SHALL BE GRADE 60 FOR #4 BAR & LARGER BUT MAY BE GRADE 40 FOR #3 AND SMALLER BARS. 8. THE THICKNESS OF CONCRETE FLOOR SLABS SUPPORTED DIRECTLY ON THE GROUND SHALL NOT BE LESS THAN 3.5" (98 MM). A6-MIL (0.006 INCH; 0.15 MM) POLYETHYLENE VAPOR RETARDER. CONTROL JOINTS @ 25' O.C. MAX EA. DIR. OR CENTERED PER OWNER PREFERENCE. 9. DAMP PROOFING PER 2018 IBC SECTION 1805.2 10. PRESSURE TREATED SILL PLATE AT PERIMETER OF FOUNDATION DR A W N B Y : CH K ' D B Y : BH A W B S PL O T D A T E : 12 / 2 0 / 2 0 2 1 EN G I N E E R : R A Y M C D O U G A L , P E DE S C R I P T I O N RE V I S I O N D A T E FO U N D A T I O N SH E E T T I T L E : SHEET 4 S-101 10 6 6 N o r t h Y e l l o w s t o n e H w y Re x b u r g , I D 8 3 4 4 0 ww w . s o u t h f o r k e n g i n e e r i n g . c o m 20 8 - 8 5 2 - 6 2 3 6 So u t h F o r k D e s i g n G r o u p , L L C Co p y r i g h t 2 0 1 6 | S o u t h f o r k E n g i n e e r i n g | A l l R i g h t s R e s e r v e d . PO R T E R R V 10 5 0 N O R T H 2 N D E A S T RE X B U R G , I D 12/20/2021 All wood in contact with concrete needs to be pressure treated. 6 City ordinance calls for top horizontal to be placed in top 6". City ordinance calls for all footings to have a minimum 2 #4 bars continuous. T R U S S E S P E R M A N U F A C T U R E R 6-3/4x12 24F-V4 GLULAM 1 ROOF LAYOUTROOF LAYOUTROOF LAYOUTROOF LAYOUT SCALE: SCALE: SCALE: SCALE: 3/16" = 1'-0"3/16" = 1'-0"3/16" = 1'-0"3/16" = 1'-0" ROOF FRAMING NOTE:ROOF FRAMING NOTE:ROOF FRAMING NOTE:ROOF FRAMING NOTE: 1. MANUFACTURED TRUSSES DESIGN PER MANUFACTURER. 2. SIMPSON H1 TIES @ EA. TRUSS. 3. PROVIDE GANG STUDS UNDER ALL GIRDER TRUSSES PLY TO MATCH PLY OF GIRDER TRUSS. 3. PROVIDE ATTIC VENTILATION @ 1:150 OR LOCAL CODE. 4. 5/8 OSB DECKING 16 GAGE STAPLES 4/12 SPACING. 5. ICE /WATER BARRIER @ ALL EDGES, EVES, GABLES, RIDGES & VALLEYS TO 24" OF INTERIOR DIMENSION. 6. #15 ROOFING FELT MINIMUM. 7. DRIP EDGE & SHINGLES/METAL PER OWNER/BUILDER. 8. FASCIA/SOFFIT TO MATCH SIDING . DR A W N B Y : CH K ' D B Y : BH A W B S PL O T D A T E : 12 / 2 0 / 2 0 2 1 EN G I N E E R : R A Y M C D O U G A L , P E DE S C R I P T I O N RE V I S I O N D A T E RO O F F R A M I N G SH E E T T I T L E : SHEET 5 S-301 10 6 6 N o r t h Y e l l o w s t o n e H w y Re x b u r g , I D 8 3 4 4 0 ww w . s o u t h f o r k e n g i n e e r i n g . c o m 20 8 - 8 5 2 - 6 2 3 6 So u t h F o r k D e s i g n G r o u p , L L C Co p y r i g h t 2 0 1 6 | S o u t h f o r k E n g i n e e r i n g | A l l R i g h t s R e s e r v e d . PO R T E R R V 10 5 0 N O R T H 2 N D E A S T RE X B U R G , I D 12/20/2021 Need engineered truss plans. Be l o w F r o s t 6" M i n 1 5 4 3 2 7 6 8 KEYNOTES 1 - FOOTING, SEE PLAN AND SCHEDULE FOR SIZE AND REINF. 2 - CONCRETE WALL 3 - CONCRETE SLAB 4 - CONT. SILL PLATE AND ANCHOR BOLTS 5 - WALL STUDS 6 - WALL SHEATHING 7 - REQ'D PANEL EDGE NAILING 8 - J-BOLTS SIZE/TYPE PER PLAN 6 6 6 6 1 48 1 7 2 13 3 4 5 3 1 32 4 5 EXTERIOR SHEATHING AT CORNER INTERIOR SHEATHING AT CORNER INTERIOR SHEATHING AT WALL INTERSECTION KEYNOTES 1 - EDGE NAILING PER SHEAR WALL SCHEDULE. 2 - WALL SHEATHING AS OCCURS. 3 - LOCATION OF STRAP AT END OF SHEAR WALL, SEE PLAN FOR TYPE OF STRAP. 4 - FULL HEIGHT WOOD STUD TYP. 5 - 16d FACE NAIL AT 16" O.C. 6 - DISTANCE FROM CORNERS TO CENTER OF STRAP EQUALS WIDTH OF WALL (MAX.) 7 - 16d FACE NAIL AT 6" O.C. Nail Through Sheathing To Beam (TYP) Second Header If Applicable 2x Gang Stud (TYP) See Header Schedule For Sizing & Type -See Shear Wall Note For Sheathing And Fastening Details. -Extend Sheathing From Sill Plate To Top Of Beam -See Foundation Plan For Hold Downs. 8 732" TYP. WITH SOLID BLOCKING 10 3 9 12 3 4 6 5 3 TYP. DOOR OPENING TYP. WINDOW OPENING B B A SECTION A SECTION B KEYNOTES 1 - HEADER BEARING TRIMMERS OR HEADERS 2 - FULL HEIGHT STUD FLOOR TO FLOOR 3 - A.P.A. RATED WALL SHEATHING 4 - REQ'D PANEL EDGE NAILING 5 - COIL STRAP 6 - 2x FLAT BLOCKING 7 - HEADER AT DOOR OR WINDOW, TYP. 8 - CEILING OR FLOOR LINE 9 - FLOOR LINE 10 - SIMPSON CS16 COILED STRAP CUT TO FIT EACH OPENING TOP AND BOTTOM (TOP ONLY AT DOORS) FILL EVERY OTHER NAIL HOLE WITH 8d COMMON NAILS 3 STUD WALL TO CONCRETE WALL CONNECTIONSTUD WALL TO CONCRETE WALL CONNECTIONSTUD WALL TO CONCRETE WALL CONNECTIONSTUD WALL TO CONCRETE WALL CONNECTION NOT TO NOT TO NOT TO NOT TO SCALESCALESCALESCALE 2 TYPICAL SHEAR SHEATHING @ WALL INTERSECTIONTYPICAL SHEAR SHEATHING @ WALL INTERSECTIONTYPICAL SHEAR SHEATHING @ WALL INTERSECTIONTYPICAL SHEAR SHEATHING @ WALL INTERSECTION NOT TO NOT TO NOT TO NOT TO SCALESCALESCALESCALE 4 WALL FRAMING @ GARAGE DOORSWALL FRAMING @ GARAGE DOORSWALL FRAMING @ GARAGE DOORSWALL FRAMING @ GARAGE DOORS NOT TO NOT TO NOT TO NOT TO SCALESCALESCALESCALE 1 LATERAL TIES @ OPENINGSLATERAL TIES @ OPENINGSLATERAL TIES @ OPENINGSLATERAL TIES @ OPENINGS NOT TO NOT TO NOT TO NOT TO SCALESCALESCALESCALE GENERAL DETAILS: THESE DETAILS ARE PROVIDED FOR THE BUILDERS CONVENIENCE, AND ARE NOT NECESSARILY APPLICABLE IN ALL BUILDINGS. IT IS THE RESPONSIBILITY OF THE BUILDER/CONTRACTOR TO CONTACT THE ENGINEER OR DESIGNER FOR CLARIFICATION OR ADDITIONAL DETAILS IF NECESSARY. DR A W N B Y : CH K ' D B Y : BH A W B S PL O T D A T E : 12 / 2 0 / 2 0 2 1 EN G I N E E R : R A Y M C D O U G A L , P E DE S C R I P T I O N RE V I S I O N D A T E DE T A I L S SH E E T T I T L E : SHEET 6 R-101 10 6 6 N o r t h Y e l l o w s t o n e H w y Re x b u r g , I D 8 3 4 4 0 ww w . s o u t h f o r k e n g i n e e r i n g . c o m 20 8 - 8 5 2 - 6 2 3 6 So u t h F o r k D e s i g n G r o u p , L L C Co p y r i g h t 2 0 1 6 | S o u t h f o r k E n g i n e e r i n g | A l l R i g h t s R e s e r v e d . PO R T E R R V 10 5 0 N O R T H 2 N D E A S T RE X B U R G , I D 12/20/2021 36"