Loading...
HomeMy WebLinkAboutREDLINED LOT LAYOUT - 21-00511 - Iron Horse RV Dealership - Outer ShellAuthor Name Author Email Author Phone No.: Kyle Baldwin Kyle.Baldwin@rexburg.org 208-372-2164 Cody Jones Cody.Jones@rexburg.org 208-372-2173 Description : Iron Horse RV Dealership Address : 1076 S 12th W Application Type : Document Filename : LOT LAYOUT PLAN 7.07.2021 - 21-00511 - 1076 S 12th W - Iron Horse RV Dealership.pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments Pg 1 Free text Cody Jones : Building Open 1 Sidewalk to be built to city specs. Pg 1 Free text Kyle Baldwin : P&Z Open 1 Please provide drawings of exterior elevations. Elevations must conform to Rexburg Development Code Section 6.00.110 Facades of Structures Less Than 25,000 sq ft Pg 1 Callout Kyle Baldwin : P&Z Open 1 Please show location of proposed monument sign # 21-00511 New Commercial Building Report Date: 07.21.2021 Approval of plans does not constitute approval of variance from code Page 1 of 1 Powered by TCPDF (www.tcpdf.org) s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s w w w w w w w w w w w w w w w w w w t o e t o e t o e t o e t o e to e t o e t o e t o e t o e t o e t o e to e to e to e t o e t o e to e to e PP 22' 161.7' 15' PUE R 4 . 5 ' R5 . 5 ' R 5 . 5 ' R 9 . 5 ' R2 . 5 ' R 2 . 5 ' R2.5' R 4 . 5 ' R19 . 3 ' R2. 5 ' R 2 . 5 ' R 2 0 ' 15' PUE R 5 ' 15' 26 5 ' 6' 2 6 9 . 5 ' 9 9 ' 35' 50' 4 ' 17' 167' 1 0 0 ' 175' 242.6' 30.8' 5 3 . 6 ' 40'40' 7 ' 31.9' 3 4 2 . 9 ' 113.6' 198.7' 1 2 2 7 ' 9.5' 20.5' 34' 30' 9 ' T Y P 20' TYP 135.6' 6 5 . 3 ' 375.7' 20.5'9.5' 242.6' 50' 5' 147.7' 9 8 . 6 ' 54' 19' 24' 1 2 ' 7.1 ' 59.3' 5 ' 36' PUE/CAE 6' 6' 3' 9 ' T Y P 20' TYP 5' 7' 6' 62' 5 4 ' 4 6 ' 4 3 . 3 ' 7.3' 1 3 . 3 ' 7.3' 4 3 . 3 ' 9 1 . 7 ' 16.5' 4 ' 16.5' 3' 21.4' 7. 8 '8' 6 . 7 ' 8' 1 4 ' 15' 7.7' 22' TYP 9 ' T Y P 4.2 ' 90.7' 20 ' 3' 4.2 ' 15 ' 12.5 ' 71.9' 4 . 2 ' 14.5' 24' 1 2 ' 3 3 . 5 ' 3 6' 56 2 . 3 ' RE V I S I O N S RE V # DA T E DR A W I N G I N F O DA T E DE S I G N E D DR A W N *S E E G E N E R A L N O T E S S H E E T WA R N I N G 0 1 2 IF T H I S B A R D O E S N O T ME A S U R E 2 " T H E N DR A W I N G I S N O T T O S C A L E CO N S T R U C T I O N S E T ww w . h o r r o c k s . c o m PAGE PR O J E C T CH E C K E D # 21 9 4 S n a k e R i v e r P a r k w a y , S u i t e 2 0 5 Id a h o F a l l s , I D 8 3 4 0 2 (2 0 8 ) 5 2 2 - 1 2 2 3 ID - 2 6 7 6 - 2 0 0 9 LT S CJ F CJ F 05 / 1 0 / 2 0 2 1 SI T E P L A N - C E N T R A L BV I R O N H O R S E I RE X B U R G , I D A H O 8 C.3.2 H O R R O C K S E N G I N E E R SN 0 30'60' SCALE: 1" = 30' 02 03 05 5 6 06 08 06 19 13 18 21 21 12 07 20 07 08 01 13 05 0505 05 05 08 21 21 21 22 10 19 06 06 17 PROPOSED BUILDING ±17,500 SFRV SALES LOT 22 SITE PLAN- NORTH MATCH LINE SITE PLAN- CENTRAL SITE PLAN- CENTRAL MATCH LINE SITE PLAN- SOUTH 1 2 T H S T R E E T LOT 5 09 PRIVATE DRIVE PR I V A T E D R I V E 10 2123 C.3.1 3 C.3.1 5 18 15 15 15 1515 15 15 15 15 15 15 24 CURB RAMP W/ TRUNCATED DOMES PER CITY OF REXBURG STANDARDS ADA ACCESSIBLE PARKING STALL, DIMENSIONS PER PLAN UNLESS OTHERWISE NOTED ADA HANDICAP SIGN SEE DETAIL 2 THIS SHEET INSTALL TRASH PAD & ENCLOSURE PER CITY OF REXBURG SD-11 1.5' FLAT PAN CURB & GUTTER SEE DETAIL 1 THIS SHEET 4" THICK SIDEWALK. WIDTH VARIES PER ISPWC SD-709, SD-714, SD-714A & SD-714B HEAVY DUTY ASPHALT, SEE SHEET C.3.0 ALL STRIPING PER MUTCD STANDARDS SNOW STORAGE AREA (SEE LANDSCAPE TABLE FOR AREA) INSTALL PORTLAND CEMENT CONCRETE PAVEMENT SEE PAVEMENT SECTION SUMMARY SHEET C.3.0 INSTALL CURB TAPER PER ISPWC SD-707 (LENGTH PER PLANS) INSTALL CROSS DRAIN PER CITY OF REXBURG SD-7 INSTALL CURB & GUTTER PER CITY OF REXBURG SD-3 PROPOSED MONUMENT SIGN, SEE ARCHITECTURAL PLANS FOR DETAILS SIGN & LIGHT LOCATIONS (REFER TO ARCHITECTURAL AND ELECTRICAL PLANS FOR DETAILS) SIGNS SHOWN IN APPROXIMATE LOCATION (SIGNS N.I.C) ELECTRICAL TRANSFORMER PAD. SEE ELECTRICAL PLANS FOR DETAILS INSTALL CRUSHED AGGREGATE BASE AND STRUCTURAL SUBBASE PER FLEXIBLE PAVEMENT SUMMARY INSTALL PAVERS PER LANDSCAPE PLANS INSTALL 3' CURB TERMINUS PER ISPWC SD-707 INSTALL TYPICAL SECTION PER CITY OF REXBURG SD-3 TYPICAL SECTION 5 SEE DETAIL 3 SHEET C.3.1 LANDSCAPED AREA, SEE LANDSCAPE PLAN CURB & GUTTER TRANSITION FROM CITY OF REXBURG SD-3 TO 1.5" FLAT PAN CURB INSTALL RV DUMP STATION PROPOSED POWER POLE LOCATION INSTALL CRUSHED AGGREGATE BASE PER FLEXIBLE PAVEMENT SUMMARY INSTALL RIBBON CURB PER DETAIL 7 SEE SHEET C.3.1 INSTALL MOUNTABLE CURB PER ISPWC SD-701B SITE PLAN KEY NOTES: 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 26 27 27 27 27 27 27 06/21/21 Please provide drawings of exterior elevations. Elevations must conform to Rexburg Development Code Section 6.00.110 Facades of Structures Less Than 25,000 sq ft Please show location of proposed monument sign Sidewalk to be built to city specs.