Loading...
HomeMy WebLinkAboutAPPROVED PLANS - 21-00121 - 39 N Hidden Valley Rd - Solar PanelsAuthor Name Author Email Author Phone No.: Bret Stoddard brets@rexburg.org 208-372-2171 Larry Beesley Larry.Beesley@rexburg.org 208-372-2176 Description : 39 N Hidden Valley Rd - Solar Panels Address : 39 N Hidden Valley Rd Record Type : Solar Panels Document Filename : Ron Call_Plans_V1.pdf Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Approved # 21-00121 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments PV-0 Stamp Larry Beesley : Building Open 1 PV-1 Stamp Larry Beesley : Building Open 2 PV-2 Stamp Larry Beesley : Building Open 3 PV-3 Stamp Larry Beesley : Building Open 4 PV-4 Stamp Larry Beesley : Building Open 5 PV-13 Stamp Larry Beesley : Building Open 14 PV-14 Stamp Larry Beesley : Building Open 15 PV-0 Stamp Bret Stoddard : Electrical Open 1 Approved - Electrical Inspector PV-0 Callout Bret Stoddard : Electrical Open 1 Wind exposure is "C". PV-1 Stamp Bret Stoddard : Electrical Open 2 Approved - Electrical Inspector PV-2 Stamp Bret Stoddard : Electrical Open 3 Approved - Electrical Inspector Solar Panels This plan is good and meets the requirements of the code. Approval of plans does not constitute approval of variance from code Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments PV-3 Stamp Bret Stoddard : Electrical Open 4 Approved - Electrical Inspector PV-4 Stamp Bret Stoddard : Electrical Open 5 Approved - Electrical Inspector PV-5 Stamp Bret Stoddard : Electrical Open 6 Approved - Electrical Inspector PV-6 Stamp Bret Stoddard : Electrical Open 7 Approved - Electrical Inspector PV-7 Stamp Bret Stoddard : Electrical Open 8 Approved - Electrical Inspector PV-8 Stamp Bret Stoddard : Electrical Open 9 Approved - Electrical Inspector PV-9 Stamp Bret Stoddard : Electrical Open 10 Approved - Electrical Inspector PV-10 Stamp Bret Stoddard : Electrical Open 11 Approved - Electrical Inspector PV-11 Stamp Bret Stoddard : Electrical Open 12 Approved - Electrical Inspector P-12 Stamp Bret Stoddard : Electrical Open 13 Approved - Electrical Inspector PV-13 Stamp Bret Stoddard : Electrical Open 14 Approved - Electrical Inspector PV-14 Stamp Bret Stoddard : Electrical Open 15 Approved - Electrical Inspector PV-15 Stamp Bret Stoddard : Electrical Open 16 Approved - Electrical Inspector PV-16 Stamp Bret Stoddard : Electrical Open 17 Approved - Electrical Inspector PV-17 Stamp Bret Stoddard : Electrical Open 18 Approved - Electrical Inspector Approval of plans does not constitute approval of variance from code Powered by TCPDF (www.tcpdf.org) P R O J E C T S I T E C O V E R S H E E T 2 V I C I N I T Y M A P S C A L E : N T S P V - 0 1AERIAL PH O T O S C A L E : N T S PV-0 GENERAL NOTES·THE CONTRACTOR/INSTALLER OF THE SOLAR PVSYSTEM OVER EXISTING ROOF SHALL CONFORM TOOSHA REQUIREMENTS DURING THE CONSTRUCTIONPHASE. JOB SAFETY AND CONSTRUCTIONPROCEDURES ARE THE SOLE RESPONSIBILITY OFTHE CONTRACTOR/INSTALLER.·REFER TO ELECTRICAL DRAWING PV-5 FOR PANELDETAILED INFORMATION.·IN CASE OF CONFLICT BETWEEN STRUCTURALDRAWINGS AND ELECTRICAL DRAWINGS, THE MOSTRIGID REQUIREMENTS SHALL GOVERN.·THE CONTRACTOR/INSTALLER SHALL VERIFY ALLEXISTING BUILDING INFORMATION SHOWN(DIMENSIONS, ROOF TOP PROJECTIONS, ETC.) ANDNOTIFY THE ENGINEER OF ANY DISCREPANCIESPRIOR TO INSTALLATIONS OF PV SYSTEM.·THE CONTRACTOR/INSTALLER SHALL VERIFY ANDCOORDINATE EXISTING OPENINGS, ROOF TOP UNITS,VENT PIPES, ETC. SHOWN ON DRAWINGS. IF THERE ISA DISCREPANCY BETWEEN DRAWINGS, IT IS THECONTRACTORS/INSTALLER'S RESPONSIBILITY TONOTIFY ENGINEER PRIOR TO PERFORMING THEWORK.·ALL CONSTRUCTION IS TO BE PERFORMED IN STRICTCONFORMANCE WITH ALL APPLICABLE TOWN,COUNTY & STATE REGULATIONS AND/OR ANY OTHERGOVERNING BODIES.· DO NOT SCALE THESE DRAWINGS, USE DIMENSIONS.CONTRACTOR MUST CONDUCT ROOF SURVEY TOVERIFY DIMENSIONS SHOWN ON PLAN PRIOR TOINSTALLATION. IF THERE IS A DISCREPANCY IT ISCONTRACTOR/INSTALLER'S RESPONSIBILITY TONOTIFY THE ENGINEER IMMEDIATELY.PHOTOVOLTA I C R O O F M O U N T S Y S T E M 28 MODULES- R O O F M O U N T E D - 8 . 9 6 k W D C , 1 0 . 0 0 k W A C 39 NORTH HID D E N V A L L E Y R D , R E X B U R G , I D 8 3 4 4 0 U S A R E V S H E E T N A M E S H E E T N U M B E R D A T E D E S C R I P T I O N V E R S I O N P V - 0 P R O J E C T N A M E U R 1 0 / 3 0 / 2 0 2 0 I N I T I A L R E L E A S E RON CALL 39 NORTH HIDDEN VALLEY RD, REXBURG, ID 83440 USA APN# RPRHDVY0000060 UTILITY: PACIFICORP AHJ: CITY OF REXBURG B E L L O S O L A R 3 4 6 3 M A G I C D R , S U I T E 2 0 0 3 S A N A N T O N I O , T X , 7 8 2 2 9 T E L : ( 8 0 1 ) 9 8 9 - 3 5 8 5 E m a i l : d e s i g n @ b e l l o s o l a r . c o m SYSTEM SUMMARY:ROOF TYPE: - ASPHALT SHINGLENUMBER OF LAYERS: - 01ROOF FRAME: - 2"x4" TRUSSES @24" O.C.STORY: - SINGLE STORYSNOW LOAD : - 50 PSFWIND SPEED :- 115 MPHWIND EXPOSURE:- B DESIGN CRITERIA: A R R A Y L O C A T I O N P V - 0 C O V E R S H E E T P V - 1 S I T E P L A N W I T H R O O F P L A N P V - 2 R O O F P L A N W I T H M O D U L E S P V - 3 A T T A C H M E N T D E T A I L S P V - 4 S T R I N G L A Y O U T P V - 5 E L E C T R I C A L L I N E D I A G R A M P V - 6 E L E C T R I C A L C A L C U L A T I O N P V - 7 P L A C A R D S & W A R N I N G L A B E L S P V - 8 O P T I M I Z E R C H A R T P V - 9 A D D I T I O N A L N O T E S P V - 1 0 + E Q U I P M E N T S P E C S H E E T S S H E E T I N D E X G O V E R N I N G C O D E S : 2 0 1 7 N A T I O N A L E L E C T R I C A L C O D E ( N E C ) 2 0 1 5 I N T E R N A T I O N A L B U I L D I N G C O D E ( I B C ) 2 0 1 2 I N T E R N A T I O N A L R E S I D E N T I A L C O D E ( I R C ) 2 0 1 5 I N T E R N A T I O N A L M E C H A N I C A L C O D E ( I M C ) 2 0 1 2 I N T E R N A T I O N A L E N E R G Y C O N S E R V A T I O N C O D E ( I E C C ) (N) 28 - JINKO SOLAR JKM320M-60HL (320W) MODULES(N) 01 - SOLAREDGE SE10000H-US INVERTER(N) 28 - SOLAREDGE P320 POWER OPTIMIZERS(N) JUNCTION BOX(E) 200A MAIN SERVICE PANEL WITH (E) 200A MAIN BREAKER(N) 60A FUSED AC DISCONNECTWind exposure is "C". ~85.18' ~ 9 9 . 1 4 ' ~ 9 2 . 1 7 ' ~97.40' M S P U M A C D J B 2 2 ' - 3 " 1 3 ' - 7 " 10'-2"21'-1" I N V R E V S H E E T N A M E S H E E T N U M B E R D A T E D E S C R I P T I O N V E R S I O N P V - 1 P R O J E C T N A M E U R 1 0 / 3 0 / 2 0 2 0 I N I T I A L R E L E A S E RON CALL 39 NORTH HIDDEN VALLEY RD, REXBURG, ID 83440 USA APN# RPRHDVY0000060 UTILITY: PACIFICORP AHJ: CITY OF REXBURG B E L L O S O L A R 3 4 6 3 M A G I C D R , S U I T E 2 0 0 3 S A N A N T O N I O , T X , 7 8 2 2 9 T E L : ( 8 0 1 ) 9 8 9 - 3 5 8 5 E m a i l : d e s i g n @ b e l l o s o l a r . c o m SITE PLAN WITH ROOF PLAN S I T E P L A N W I T H R O O F P L A N 1SCALE: 3/32" = 1'-0" ( N ) 6 0 A F U S E D A C D I S C O N N E C T ( E ) 2 0 0 A M A I N S E R V I C E P A N E L W I T H ( E ) 2 0 0 A M A I N B R E A K E R ( E ) U T I L I T Y M E T E R 3 / 4 " E M T C O N D U I T R U N 1 / 2 " A B O V E R O O F ( N ) S O L A R E D G E S E 1 0 0 0 0 H - U S I N V E R T E R R O O F A C C E S S P O I N T PROPERTY LINE PROPERTY LINE PROPERTY LINE P R O P E R T Y L I N E E X I S T I N G D R I V E W A Y N O R T H H I D D E N V A L L E Y R D ROOF #1(28) JINKO SOLAR JKM320M-60HL(320W) MODULES ( N ) J U N C T I O N B O X 1 - S T O R Y H O U S E ( E ) T R E E S ( T Y P . ) M S P U M A C D J B 3 ' - 0 " 4 9 ' - 5 " 1 2 ' - 1 " 4'-8" 1 1 ' - 2 " 5 ' - 1 " I N V R E V S H E E T N A M E S H E E T N U M B E R D A T E D E S C R I P T I O N V E R S I O N P V - 2 P R O J E C T N A M E U R 1 0 / 3 0 / 2 0 2 0 I N I T I A L R E L E A S E RON CALL 39 NORTH HIDDEN VALLEY RD, REXBURG, ID 83440 USA APN# RPRHDVY0000060 UTILITY: PACIFICORP AHJ: CITY OF REXBURG B E L L O S O L A R 3 4 6 3 M A G I C D R , S U I T E 2 0 0 3 S A N A N T O N I O , T X , 7 8 2 2 9 T E L : ( 8 0 1 ) 9 8 9 - 3 5 8 5 E m a i l : d e s i g n @ b e l l o s o l a r . c o m ROOF PLAN WITH MODULESSCALE: 3/32" = 1'-0"1 R O O F P L A N W I T H M O D U L E S · P L U M B I N G V E N T S , S K Y L I G H T S A N D M E C H A N I C A L V E N T S S H A L L N O T B E C O V E R E D , M O V E D , R E - R O U T E D O R R E - L O C A T E D . MODULE TYPE, DIMENSIONS & WEIGHTNUMBER OF MODULES = 28 MODULESMODULE TYPE = JINKO SOLAR JKM320M-60HL (320W) MODULESMODULE WEIGHT = 41.9 LBS / 19.0 KG.MODULE DIMENSIONS = 66.3"X 39.45" = 18.16 SFUNIT WEIGHT OF ARRAY = 2.31 PSF A R R A Y A R E A & R O O F A R E A C A L C ' S R O O F # O F M O D U L E S A R R A Y A R E A ( S q . F t . ) R O O F A R E A ( S q . F t . ) R O O F A R E A C O V E R E D B Y A R R A Y ( % ) # 1 2 8 5 0 8 . 5 8 1 3 9 7 . 9 5 3 6 . 3 8 L E G E N D - J U N C T I O N B O X J B M S P - M A I N S E R V I C E P A N E L - V E N T , A T T I C F A N ( R O O F O B S T R U C T I O N ) - R O O F A T T A C H M E N T - T R U S S E S - C O N D U I T - F I R E P A T H W A Y I N V - I N V E R T E R U M - U T I L I T Y M E T E R R O O F Z O N E 3 R O O F D E S C R I P T I O N R O O F T Y P E A S P H A L T S H I N G L E R O O F R O O F T I L T A Z I M U T H T R U S S E S S I Z E T R U S S E S S P A C I N G # 1 3 0 ° 2 6 8 ° 2 " x 4 " 2 4 " o . c . 66.3"39.45"PHOTOVOLTAIC MODULESJINKO SOLAR JKM320M-60HL(320W) - A C D I S C O N N E C T A C D ROOF ZONE 2ROOF ZONE 1 N O T E : " A C T U A L R O O F C O N D I T I O N S A N D R A F T E R ( O R S E A M ) L O C A T I O N S M A Y V A R Y . I N S T A L L P E R M A N U F A C T U R E R ( S ) I N S T A L L A T I O N G U I D E L I N E S A N D E N G I N E E R E D S P A N S F O R A T T A C H M E N T S . " ( E ) 2 0 0 A M A I N S E R V I C E P A N E L W I T H ( E ) 2 0 0 A M A I N B R E A K E R ( E ) U T I L I T Y M E T E R 3 / 4 " E M T C O N D U I T R U N 1 / 2 " A B O V E R O O F ( N ) S O L A R E D G E S E 1 0 0 0 0 H - U S I N V E R T E R ROOF #1(28) JINKO SOLAR JKM320M-60HL(320W) MODULES ( N ) J U N C T I O N B O X (N) PEGASUS COMP MOUNTATTACHMENTS @ 72" O.C.(N) IRONRIDGE XR-100 RAIL(E) 2"x4" TRUSSES @ 24" O.C. (TYP.) N O R T H H I D D E N V A L L E Y R D F R O N T Y A R D BACK YARD ROOF #1TILT - 30AZIM. - 268 1 8 " F I R E S E T B A C K 1 8 " F I R E S E T B A C K 1 8 " F I R E S E T B A C K 1 8 " F I R E S E T B A C K 3 6 " F I R E S E T B A C K 3 6 " F I R E S E T B A C K ( N ) 6 0 A F U S E D A C D I S C O N N E C T S P E C I F I C A T I O N S C O M P . L - F O O T I N S T A L L K I T C O N T E N T S F L A S H I N G , L - F O O T , L A G R O O F T Y P E A S P H A L T S H I N G L E C E R T I F I C A T I O N S I B C , A S C E / S E I 7 - 1 0 I N S T A L L A P P L I C A T I O N R A I L E D S Y S T E M S C O M P A T I B L E R A I L A L L L A G S C R E W H A R D W A R E 5 / 1 6 " S S W / W A S H E R F L A S H I N G M A T E R I A L P A I N T E D G A L V A L U M E P L U S L - F O O T M A T E R I A L C A S T A L U M I N U M R R C L F O O M I B D K - 2 4 S K U R E V S H E E T N A M E S H E E T N U M B E R D A T E D E S C R I P T I O N V E R S I O N P V - 3 P R O J E C T N A M E U R 1 0 / 3 0 / 2 0 2 0 I N I T I A L R E L E A S E RON CALL 39 NORTH HIDDEN VALLEY RD, REXBURG, ID 83440 USA APN# RPRHDVY0000060 UTILITY: PACIFICORP AHJ: CITY OF REXBURG B E L L O S O L A R 3 4 6 3 M A G I C D R , S U I T E 2 0 0 3 S A N A N T O N I O , T X , 7 8 2 2 9 T E L : ( 8 0 1 ) 9 8 9 - 3 5 8 5 E m a i l : d e s i g n @ b e l l o s o l a r . c o m A T T A C H M E N T D E T A I L NOTES:- 5/16" LAG BOLTS MUST EMBED 2.5" INTO ROOF STRUCTURA L MEMBERS/RAFTERS- TORQUE ALL 5/16" HARDWARE TO THE FOLLOWING:- SILVER S.S. 10-16 FT-LBS- BLACK S.S. 7-9 FT-BLS- RAILS MOUNT TO DOWN SLOPE SIDE OF L FOOTMODULE85 ± 5 IN-LBS(9.6 N-m)MODULEIRONRIDGE XR-100 RAIL85 ± 5 IN-LBS(9.6 N-m)IRONRIDGE XR-100 R A I L MODULEEND CLAMPCUTAWAY THE ENDCLAMP IS INSIDE TH E R A I L I R O N R I D G E X R - 1 0 0 R A I L ( 1 ) 5 / 1 6 " D I A X 3 " M I N . E M B E D M E N T L A G S C R E W A T E A C H A T T A C H M E N T P O I N T I N T O E X I S T I N G F R A M I N G ( E ) A S P H A L T S H I N G L E R O O F ( N ) C A P S C R E W , H E X H E A D , 5 / 1 6 - 1 8 x 1 " U N C - 2 A . 1 8 - 8 S S P E G A S U S C O M P F L A S H I N G P E G A S U S C O M P F L A S H I N G D E T A I L ATTACHMENT DETAIL1SCALE: NTS N O T E : " A C T U A L R O O F C O N D I T I O N S A N D R A F T E R ( O R S E A M ) L O C A T I O N S M A Y V A R Y . I N S T A L L P E R M A N U F A C T U R E R ( S ) I N S T A L L A T I O N G U I D E L I N E S A N D E N G I N E E R E D S P A N S F O R A T T A C H M E N T S . " ( E ) 2 " x 4 " T R U S S E S @ 2 4 " O . C . ( T Y P . ) R E V S H E E T N A M E S H E E T N U M B E R D A T E D E S C R I P T I O N V E R S I O N P V - 4 P R O J E C T N A M E U R 1 0 / 3 0 / 2 0 2 0 I N I T I A L R E L E A S E RON CALL 39 NORTH HIDDEN VALLEY RD, REXBURG, ID 83440 USA APN# RPRHDVY0000060 UTILITY: PACIFICORP AHJ: CITY OF REXBURG B E L L O S O L A R 3 4 6 3 M A G I C D R , S U I T E 2 0 0 3 S A N A N T O N I O , T X , 7 8 2 2 9 T E L : ( 8 0 1 ) 9 8 9 - 3 5 8 5 E m a i l : d e s i g n @ b e l l o s o l a r . c o m S T R I N G L A Y O U T STRING LAYOUTSCALE: 1/8"=1'-0"1 6 6 . 3 " 39.45" P H O T O V O L T A I C M O D U L E S J I N K O S O L A R J K M 3 2 0 M - 6 0 H L (28) JINKO SOLAR JKM320M-60HL (320W) MODULES(28) SOLAREDGE P320 POWER OPTIMIZERS(02) STRINGS OF 14 MODULES CONNECTED IN SERIES PER STRING(28) SOLAREDGE P320 POWER OPTIMIZERS STRING #1ROOF #1(28) JINKO SOLAR JKM320M-60HL(320W) MODULES N O R T H H I D D E N V A L L E Y R D F R O N T Y A R D BACK YARD 1 8 " F I R E S E T B A C K 1 8 " F I R E S E T B A C K 3 6 " F I R E S E T B A C K 3 6 " F I R E S E T B A C K 1 8 " F I R E S E T B A C K 1 8 " F I R E S E T B A C K S T R I N G # 2 R E V S H E E T N A M E S H E E T N U M B E R D A T E D E S C R I P T I O N V E R S I O N P V - 5 P R O J E C T N A M E U R 1 0 / 3 0 / 2 0 2 0 I N I T I A L R E L E A S E RON CALL 39 NORTH HIDDEN VALLEY RD, REXBURG, ID 83440 USA APN# RPRHDVY0000060 UTILITY: PACIFICORP AHJ: CITY OF REXBURG B E L L O S O L A R 3 4 6 3 M A G I C D R , S U I T E 2 0 0 3 S A N A N T O N I O , T X , 7 8 2 2 9 T E L : ( 8 0 1 ) 9 8 9 - 3 5 8 5 E m a i l : d e s i g n @ b e l l o s o l a r . c o m E L E C T R I C A L L I N E D I A G R A M B I L L O F M A T E R I A L S E Q U I P M E N T Q T Y D E S C R I P T I O N S O L A R P V M O D U L E 2 8 J I N K O S O L A R J K M 3 2 0 M - 6 0 H L ( 3 2 0 W ) M O D U L E S I N V E R T E R 1 S O L A R E D G E S E 1 0 0 0 0 H - U S I N V E R T E R O P T I M I Z E R 2 8 S O L A R E D G E P 3 2 0 P O W E R O P T I M I Z E R S J U N C T I O N B O X 1 6 0 0 V , 5 5 A M A X , 4 I N P U T S , M O U N T E D O N R O O F F O R W I R E & C O N D U I T T R A N S I T I O N A C D I S C O N N E C T 1 2 4 0 V A C , 6 0 A F U S E D A C D I S C O N N E C T W I T H 6 0 A F U S E S , N E M A 3 R , U L L I S T E D ELECTRICAL LINE DIAGRAM1SCALE: NTS SYSTEM SIZE:- 28 x 320W = 8.96 kWDC 1 x 10000W = 10.00 kWACJUNCTION BOX #2#1#14 D C A C #2#1#14 3 / 4 " C O N D U I T ( 2 ) # 1 0 A W G T H W N - 2 + R E D ( 2 ) # 1 0 A W G T H W N - 2 - B L A C K ( 1 ) # 1 0 T H W N - 2 G N D S O L A R E D G E : S E 1 0 0 0 0 H - U S ( 2 4 0 V ) O U T P U T : 2 4 0 V A C , 4 2 A 9 9 % C E C W E I G H T E D E F F I C I E N C Y N E M A 3 R , U L L I S T E D , I N T E R N A L G F D I W I T H I N T E G R A T E D D C D I S C O N N E C T SOLAREDGE POWER OPTIMIZER P320 RATEDDC INPUT POWER - 320 WATTSMAXIMUM INPUT VOLTAGE - 48 VDCMPPT RANGE - 8 TO 48 VDCMAXIMUM INPUT CURRENT - 13.75 ADCMAXIMUM OUTPUT CURRENT - 15 ADC STRINGLIMITATIONS - 8 TO 25 OPTIMIZERS,6000 WATTS STC PER STRING MAXIMUMSOLAREDGE OPTIMIZERS HAVE INTEGRATEDRAPID SHUT DOWN E X I S T I N G G R O U N D I N G S Y S T E M 2 0 0 A ( E ) 2 0 0 A M A I N S E R V I C E P A N E L W I T H ( E ) 2 0 0 A M A I N B R E A K E R ( B O T T O M F E D ) L B I - D I R E C T I O N A L U T I L I T Y M E T E R 1 - P H A S E , 3 - W , 1 2 0 V / 2 4 0 V , 6 0 H z 14 MODULES CONNECTED IN STRING #114 MODULES CONNECTED IN STRING #2(2) #10 AWG PV WIRE + R e d (2) #10 AWG PV WIR E - B l a c k (1) #6 BARE CU GND ( 3 ) # 6 A W G T H W N - 2 ( 1 ) # 1 0 A W G T H W N - 2 G N D I N 3 / 4 " E M T C O N D U I T R U N L I N E S I D E T A P (28) JINKO SOLAR JKM320M-60HL (320W) MODULES(28) SOLAREDGE P320 POWER OPTIMIZERS(02) STRINGS OF 14 MODULES CONNECTED IN SERIES PER STRINGS G ( N ) 6 0 A F U S E D A C D I S C O N N E C T W I T H 6 0 A F U S E S , 2 4 0 V A C 6 0 A F U S E S R E V S H E E T N A M E S H E E T N U M B E R D A T E D E S C R I P T I O N V E R S I O N P V - 6 P R O J E C T N A M E U R 1 0 / 3 0 / 2 0 2 0 I N I T I A L R E L E A S E RON CALL 39 NORTH HIDDEN VALLEY RD, REXBURG, ID 83440 USA APN# RPRHDVY0000060 UTILITY: PACIFICORP AHJ: CITY OF REXBURG B E L L O S O L A R 3 4 6 3 M A G I C D R , S U I T E 2 0 0 3 S A N A N T O N I O , T X , 7 8 2 2 9 T E L : ( 8 0 1 ) 9 8 9 - 3 5 8 5 E m a i l : d e s i g n @ b e l l o s o l a r . c o m E L E C T R I C A L C A L C U L A T I O N DC C O N D U C T O R A M P A C I T Y C A L C U L A T I O N S : ARR A Y T O J U N C T I O N B O X : EXPECTE D W I R E T E M P ( I n C e l s i u s ) 3 3 ° TEMP. C O R R E C T I O N P E R T A B L E ( 3 1 0 . 1 6 ) 0 . 9 6 NO. OF C U R R E N T C A R R Y I N G C O N D U C T O R S 4 CONDUIT F I L L C O R R E C T I O N P E R N E C 3 1 0 . 1 5 ( B ) ( 2 ) ( a ) 0 . 8 0 CIRCUIT C O N D U C T O R S I Z E 1 0 A W G CIRCUIT C O N D U C T O R A M P A C I T Y 4 0 A REQUIRE D C I R C U I T C O N D U C T O R A M P A C I T Y P E R N E C 6 9 0 . 8 ( A & B ) 1 8 . 7 5 A 1.25 X MA X D C O U T P U T C U R R E N T DERATED A M P A C I T Y O F C I R C U I T C O N D U C T O R P E R N E C T A B L E 3 1 0 . 1 6 3 0 . 7 2 A TEMP. C O R R E C T I O N P E R T A B L E ( 3 1 0 . 1 6 ) X CONDUIT F I L L C O R R E C T I O N P E R N E C 3 1 0 . 1 5 ( B ) ( 2 ) ( a ) X C I R C U I T CONDUC T O R A M P A C I T Y Result sho u l d b e g r e a t e r t h a n ( 1 8 . 7 5 A ) o t h e r w i s e l e s s t h e e n t r y f o r c i r c u i t c o n d u c t o r s i z e a n d ampacityDC C O N D U C T O R A M P A C I T Y C A L C U L A T I O N S : FRO M J U N C T I O N B O X T O I N V E R T E R : AMBIENT T E M P E R A T U R E A D J U S T M E N T F O R E X P O S E D C O N D U I T PER NEC 3 1 0 . 1 5 ( B ) ( 2 ) ( c ) + 2 2 ° EXPECTE D W I R E T E M P ( I n C e l s i u s ) 3 3 ° + 2 2 ° = 5 5 ° TEMP. C O R R E C T I O N P E R T A B L E ( 3 1 0 . 1 6 ) 0 . 7 6 NO. OF C U R R E N T C A R R Y I N G C O N D U C T O R S 4 CONDUIT F I L L C O R R E C T I O N P E R N E C 3 1 0 . 1 5 ( B ) ( 2 ) ( a ) 0 . 8 0 CIRCUIT C O N D U C T O R S I Z E 1 0 A W G CIRCUIT C O N D U C T O R A M P A C I T Y 4 0 A REQUIRE D C I R C U I T C O N D U C T O R A M P A C I T Y P E R N E C 6 9 0 . 8 ( A & B ) 1 8 . 7 5 A 1.25 X MA X D C O U T P U T C U R R E N T DERATED A M P A C I T Y O F C I R C U I T C O N D U C T O R P E R N E C T A B L E 3 1 0 . 1 6 2 4 . 3 2 A TEMP. C O R R E C T I O N P E R T A B L E ( 3 1 0 . 1 6 ) X CONDUIT F I L L C O R R E C T I O N P E R N E C 3 1 0 . 1 5 ( B ) ( 2 ) ( a ) X C I R C U I T CONDUC T O R A M P A C I T Y Result sho u l d b e g r e a t e r t h a n ( 1 8 . 7 5 A ) o t h e r w i s e l e s s t h e e n t r y f o r c i r c u i t c o n d u c t o r s i z e a n d ampacity A C C O N D U C T O R A M P A C I T Y C A L C U L A T I O N S : I N V E R T E R T O I N T E R C O N N E C T I O N : N o . O F I N V E R T E R N O . O F C U R R E N T C A R R Y I N G C O N D U C T O R S C O N D U I T F I L L C O R R E C T I O N P E R N E C 3 1 0 . 1 5 ( B ) ( 2 ) ( a ) C I R C U I T C O N D U C T O R S I Z E 1 . 0 6 A W G 3 1 T E M P . C O R R E C T I O N P E R T A B L E ( 3 1 0 . 1 6 ) 0 . 9 6 C I R C U I T C O N D U C T O R A M P A C I T Y 7 5 A E X P E C T E D W I R E T E M P ( I n C e l s i u s ) 3 3 ° R E Q U I R E D C I R C U I T C O N D U C T O R A M P A C I T Y P E R N E C 6 9 0 . 8 ( B ) 5 2 . 5 0 A 1 . 2 5 X M A X I N V E R T E R O U T P U T C U R R E N T D E R A T E D A M P A C I T Y O F C I R C U I T C O N D U C T O R P E R N E C T A B L E 3 1 0 . 1 6 7 2 . 0 0 A T E M P . C O R R E C T I O N P E R T A B L E ( 3 1 0 . 1 6 ) X C O N D U I T F I L L C O R R E C T I O N P E R N E C 3 1 0 . 1 5 ( B ) ( 2 ) ( a ) X C I R C U I T C O N D U C T O R A M P A C I T Y R e s u l t s h o u l d b e g r e a t e r t h a n ( 5 2 . 5 0 A ) o t h e r w i s e l e s s t h e e n t r y f o r c i r c u i t c o n d u c t o r s i z e a n d a m p a c i t y NUMBER OF CURRENTCARRYING CONDUCTORS INEMT4-67-910-20 PERCENT OFVALUES.80.70.50 AMBIENT TEMPERATURE SPECSWEATHER STATION: IDAHO FALLS FANNING FIELDRECORD LOW TEMP-26°AMBIENT TEMP (HIGH TEMP 2%)33°CONDUIT HEIGHT0.5"ROOF TOP TEMP22°CONDUCTOR TEMPERATURE RATE90°MODULE TEMPERATURE COEFFICIENT OF Voc-0.28%/°COPTIMIZER SPECIFICATIONSMANUFACTURER / MODEL #SOLAREDGE P320 POWER OPTIMIZERNOMINAL OUTPUT CURRENT15AELECTRICAL NOTES1.) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLI C A T I O N . 2.) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET EN V I R O N M E N T . 3.) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DI R E C T L Y T O , A N D L O C A T E D A S C L O S E A S P O S S I B L E T O T H E N E A R E S T R I D G E , H I P , O R V A L L E Y . 4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT S H A L L C O M P L Y W I T H N E C 1 1 0 . 2 6 . 5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR S H A L L F U R N I S H A L L N E C E S S A R Y O U T L E T S , S U P P O R T S , F I T T I N G S A N D A C C E S S O R I E S T O F U L F I L L APPLICABLE CODES AND STANDARDS.6.) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIE D , T H E C O N T R A C T O R S H A L L S I Z E T H E M A C C O R D I N G L Y . 7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBL E . 8.) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MOD U L E S U P P O R T R A I L , P E R T H E G R O U N D I N G C L I P M A N U F A C T U R E R ' S I N S T R U C T I O N . 9.) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB L U G O R I L S C O G B L - 4 D B T L A Y - I N L U G . 10.) THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE INVERTER SPECIFICATIONSMANUFACTURER / MODEL #SOLAREDGE SE10000H-USNOMINAL OUTPUT VOLTAGE240 VACNOMINAL OUTPUT CURRENT42.0A SOLAR MODULE SPECIFICATIONSMANUFACTURER / MODEL #JINKO SOLAR JKM320M-60HL (305W)MODULESVMP33.40 VIMP9.59 AVOC40.9 VISC10.15 AMODULE DIMENSION66.3"L x 39.45"W x 1.38"DELECTRICAL CALCULATION1SCALE: NTS R E V S H E E T N A M E S H E E T N U M B E R D A T E D E S C R I P T I O N V E R S I O N P V - 7 P R O J E C T N A M E U R 1 0 / 3 0 / 2 0 2 0 I N I T I A L R E L E A S E RON CALL 39 NORTH HIDDEN VALLEY RD, REXBURG, ID 83440 USA APN# RPRHDVY0000060 UTILITY: PACIFICORP AHJ: CITY OF REXBURG B E L L O S O L A R 3 4 6 3 M A G I C D R , S U I T E 2 0 0 3 S A N A N T O N I O , T X , 7 8 2 2 9 T E L : ( 8 0 1 ) 9 8 9 - 3 5 8 5 E m a i l : d e s i g n @ b e l l o s o l a r . c o m P L A C A R D S & W A R N I N G L A B E L S C A U T I O N ! P O W E R T O T H I S B U I L D I N G I S A L S O S U P P L I E D F R O M T H E F O L L O W I N G S O U R C E S W I T H D I S C O N N E C T S L O C A T E D A S S H O W N A T : M A I N S E R V I C E P A N E L & U T I L I T Y M E T E R & I N V E R T E R , A C D I S C O N N E C T P V M O D U L E S WARNINGPOWER SOURCE OUTPUTCONNECTIONDO NOT RELOCATE THISOVERCURRENT DEVICE !WARNINGELECTRIC SHOCK HAZARDIF GROUND FAULT IS INDICATEDALL NORMALLY GROUNDEDCONDUCTORS MAY BEUNGROUNDED AND ENERGIZED LABEL LOCATION:AC DISCONNECT & INVERTER(PER CODE: NEC690.54)PHOTOVOLTAIC SYSTEM AC D I S C O N N E C T RATED AC OPERATING CURR E N T 4 2 . 0 A M P S AC NOMINAL OPERATING VOLT A G E 2 4 0 V O L T S LABEL LOCATION:SERVICE PANEL IF SUM OF BREAKERS EXC E E D S PANEL RATING(PER CODE: NEC 705.12 (B)(2)(c)LABEL LOCATION:AC & DC DISCONNECT AND SUB PANEL(PER CODE: NEC 690.13(B))WARNING:PHO T O V O L T A I C POWER S O U R C E LABEL LOCATION:CONDUIT, COMBINER BOX(PER CODE: NEC 690.31(G)(3)(4)LABEL LOCATION:AC & DC DISCONNECT AND SUB PANEL(PER CODE: NEC 690.41(B))TERMINALS ON THE LINE AND LOADSIDES MAY BE ENERGIZED IN THEOPEN POSITION WARNINGELECTRIC SHOCK HAZARD !RAPID SHUTDOWN SWITCHFOR SOLAR PV SYSTEMLABEL LOCATION:RAPID SHUTDOWN(PER CODE: NEC 690.56(C)(3)LABEL LOCATION:MAIN SERVICE PANEL & NET METER(PER CODE: NEC 705.12(D)(3), NEC705.12(B)(3-4) & NEC 690.59)WARNINGTHE DISCONNECTION OF THEGROUNDED CONDUCTOR(S)MAY RESULT IN OVERVOLTAGEON THE EQUIPMENT !LABEL LOCATION:INVERTER(PER CODE: NEC 690.31(I)MAIN PHOTOVOLTAICSYSTEM DISCONNECTLABEL LOCATION:MAIN SERVICE DISCONNECT / UTILITY METE R (PER CODE: NEC 690.13(B))WARNINGELECTRIC SHOCK HAZARDTERMINALS ON BOTH LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONDC VOLTAGE IS ALWAYS PRESENTWHEN SOLAR MODULES AREEXPOSED TO SUNLIGHTLABEL LOCATION:DC DISCONNECT, POINT OFINTERCONNECTION(PER CODE: NEC 690.13(B))! WARNING DUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEM !LABEL LOCATION:AC DISCONNECT/BREAKER/POINT OF CONNECTION(PER CODE: NEC 690.13(B)PHOTOVOLTAICAC DISCONNECT L A B E L L O C A T I O N : D C D I S C O N N E C T , I N V E R T E R # ( P E R C O D E : N E C 6 9 0 . 5 2 ) R A T E D M A X I M U M P O W E R - . P O I N T C U R R E N T ( I m p ) . R A T E D M A X I M U M P O W E R - . P O I N T V O L T A G E ( V m p ) . M A X I M U M S Y S T E M . V O L T A G E ( V O C ) . M A X I M U M C I R C U I T . C U R R E N T ( I s c ) . A V V A 2 2 . 4 4 0 0 4 8 0 3 0 D C D I S C O N N E C T / R A P I D S H U T D O W N S Y S T E M I F C 6 0 5 . 1 1 . 3 . 1 ( 2 ) & 6 9 0 . 5 6 ( C ) ( 1 ) ( b ) L A B E L L O C A T I O N S O L A R P V S Y S T E M E Q U I P P E D W I T H R A P I D S H U T D O W N T U R N R A P I D S H U T D O W N S W I T C H T O T H E " O F F " P O S I T I O N T O S H U T D O W N C O N D U C T O R S O U T S I D E T H E A R R A Y . C O N D U C T O R S W I T H I N T H E A R R A Y R E M A I N E N E R G I Z E D I N S U N L I G H T . S O L A R E L E C T R I C P V P A N E L S 3 9 N O R T H H I D D E N V A L L E Y R D ( E ) 2 0 0 A M A I N S E R V I C E P A N E L W I T H ( E ) 2 0 0 A M A I N B R E A K E R ( E ) U T I L I T Y M E T E R ( N ) 6 0 A F U S E D A C D I S C O N N E C T ( N ) I N V E R T E R R E V S H E E T N A M E S H E E T N U M B E R D A T E D E S C R I P T I O N V E R S I O N P V - 8 P R O J E C T N A M E U R 1 0 / 3 0 / 2 0 2 0 I N I T I A L R E L E A S E RON CALL 39 NORTH HIDDEN VALLEY RD, REXBURG, ID 83440 USA APN# RPRHDVY0000060 UTILITY: PACIFICORP AHJ: CITY OF REXBURG B E L L O S O L A R 3 4 6 3 M A G I C D R , S U I T E 2 0 0 3 S A N A N T O N I O , T X , 7 8 2 2 9 T E L : ( 8 0 1 ) 9 8 9 - 3 5 8 5 E m a i l : d e s i g n @ b e l l o s o l a r . c o m 1-10123411-2021-3031-4041-50 5 1 - 6 0 5678910 O P T I M I Z E R C H A R T P O W E R O P T I M I Z E R C H A R T N O R T H H I D D E N V A L L E Y R D R E V S H E E T N A M E S H E E T N U M B E R D A T E D E S C R I P T I O N V E R S I O N P V - 9 P R O J E C T N A M E U R 1 0 / 3 0 / 2 0 2 0 I N I T I A L R E L E A S E RON CALL 39 NORTH HIDDEN VALLEY RD, REXBURG, ID 83440 USA APN# RPRHDVY0000060 UTILITY: PACIFICORP AHJ: CITY OF REXBURG B E L L O S O L A R 3 4 6 3 M A G I C D R , S U I T E 2 0 0 3 S A N A N T O N I O , T X , 7 8 2 2 9 T E L : ( 8 0 1 ) 9 8 9 - 3 5 8 5 E m a i l : d e s i g n @ b e l l o s o l a r . c o m A D D I T I O N A L N O T E S 1.EACH MODULE TO BE GROUNDED USING THE SUPPLIED C O N N E C T I O N P O I N T P E R MANUFACTURER'S REQUIREMENTS. ALL SOLAR MODULE S , E Q U I P M E N T , A N D METALLIC COMPONENTS ARE TO BE BONDED. IF THE EXI S T I N G G R O U N D I N G ELECTRODE SYSTEM CAN NOT BE VERIFIED OR IS ONLY M E T A L L I C W A T E R P I P I N G , IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A S U P P L E M E N T A L GROUNDING ELECTRODE.2.ALL PLAQUES AND SIGNAGE REQUIRED BY THE LATEST E D I T I O N O F N A T I O N A L ELECTRICAL CODE. LABEL SHALL BE METALLIC OR PLAS T I C , E N G R A V E D O R MACHINE PRINTED IN A CONTRASTING COLOR TO THE P L A Q U E . P L A Q U E S H A L L BE UV RESISTANT IF EXPOSED TO SUNLIGHT.3.DC CONDUCTORS SHALL BE RUN IN EMT AND SHALL BE L A B E L E D , " C A U T I O N D C CIRCUIT" OR EQUIV. EVERY 5 FT.4.EXPOSED NON-CURRENT CARRYING METAL PARTS OF E L E C T R I C A L E Q U I P M E N T SHALL BE GROUNDED IN ACCORDANCE WITH 250.134 OR 2 5 0 . 1 3 6 ( A ) . 5.CONFIRM LINE SIDE VOLTAGE AT ELECTRIC UTILITY SER V I C E P R I O R T O CONNECTING INVERTER. VERIFY SERVICE VOLTAGE IS W I T H I N I N V E R T E R VOLTAGE OPERATIONAL RANGE.6.OUTDOOR EQUIPMENT SHALL BE NEMA-3R RATED OR B E T T E R . 7.ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPA N S I O N J O I N T S A N D ANCHOR CONDUIT RUNS AS REQUIRED PER NEC.8.ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVIC E S O R M E C H A N I C A L MEANS DESIGNED AND LISTED FOR SUCH USE, AND FOR R O O F - M O U N T E D SYSTEMS, WIRING MUST BE PERMANENTLY AND COMPL E T E L Y H E L P O F F O F T H E ROOF SURFACE. NEC 110.2 - 110.4 / 300.49.ALL ROOF PENETRATIONS MUST BE FLASHED. SIMPLY C A U L K I N G D O E S N O T SUFFICE. R E V S H E E T N A M E S H E E T N U M B E R D A T E D E S C R I P T I O N V E R S I O N P V - 1 0 P R O J E C T N A M E U R 1 0 / 3 0 / 2 0 2 0 I N I T I A L R E L E A S E RON CALL 39 NORTH HIDDEN VALLEY RD, REXBURG, ID 83440 USA APN# RPRHDVY0000060 UTILITY: PACIFICORP AHJ: CITY OF REXBURG B E L L O S O L A R 3 4 6 3 M A G I C D R , S U I T E 2 0 0 3 S A N A N T O N I O , T X , 7 8 2 2 9 T E L : ( 8 0 1 ) 9 8 9 - 3 5 8 5 E m a i l : d e s i g n @ b e l l o s o l a r . c o m S P E C S H E E T S R E V S H E E T N A M E S H E E T N U M B E R D A T E D E S C R I P T I O N V E R S I O N P V - 1 1 P R O J E C T N A M E U R 1 0 / 3 0 / 2 0 2 0 I N I T I A L R E L E A S E RON CALL 39 NORTH HIDDEN VALLEY RD, REXBURG, ID 83440 USA APN# RPRHDVY0000060 UTILITY: PACIFICORP AHJ: CITY OF REXBURG B E L L O S O L A R 3 4 6 3 M A G I C D R , S U I T E 2 0 0 3 S A N A N T O N I O , T X , 7 8 2 2 9 T E L : ( 8 0 1 ) 9 8 9 - 3 5 8 5 E m a i l : d e s i g n @ b e l l o s o l a r . c o m S P E C S H E E T S R E V S H E E T N A M E S H E E T N U M B E R D A T E D E S C R I P T I O N V E R S I O N P - 1 2 P R O J E C T N A M E U R 1 0 / 3 0 / 2 0 2 0 I N I T I A L R E L E A S E RON CALL 39 NORTH HIDDEN VALLEY RD, REXBURG, ID 83440 USA APN# RPRHDVY0000060 UTILITY: PACIFICORP AHJ: CITY OF REXBURG B E L L O S O L A R 3 4 6 3 M A G I C D R , S U I T E 2 0 0 3 S A N A N T O N I O , T X , 7 8 2 2 9 T E L : ( 8 0 1 ) 9 8 9 - 3 5 8 5 E m a i l : d e s i g n @ b e l l o s o l a r . c o m S P E C S H E E T S R E V S H E E T N A M E S H E E T N U M B E R D A T E D E S C R I P T I O N V E R S I O N P V - 1 3 P R O J E C T N A M E U R 1 0 / 3 0 / 2 0 2 0 I N I T I A L R E L E A S E RON CALL 39 NORTH HIDDEN VALLEY RD, REXBURG, ID 83440 USA APN# RPRHDVY0000060 UTILITY: PACIFICORP AHJ: CITY OF REXBURG B E L L O S O L A R 3 4 6 3 M A G I C D R , S U I T E 2 0 0 3 S A N A N T O N I O , T X , 7 8 2 2 9 T E L : ( 8 0 1 ) 9 8 9 - 3 5 8 5 E m a i l : d e s i g n @ b e l l o s o l a r . c o m S P E C S H E E T S R E V S H E E T N A M E S H E E T N U M B E R D A T E D E S C R I P T I O N V E R S I O N P V - 1 4 P R O J E C T N A M E U R 1 0 / 3 0 / 2 0 2 0 I N I T I A L R E L E A S E RON CALL 39 NORTH HIDDEN VALLEY RD, REXBURG, ID 83440 USA APN# RPRHDVY0000060 UTILITY: PACIFICORP AHJ: CITY OF REXBURG B E L L O S O L A R 3 4 6 3 M A G I C D R , S U I T E 2 0 0 3 S A N A N T O N I O , T X , 7 8 2 2 9 T E L : ( 8 0 1 ) 9 8 9 - 3 5 8 5 E m a i l : d e s i g n @ b e l l o s o l a r . c o m S P E C S H E E T S R E V S H E E T N A M E S H E E T N U M B E R D A T E D E S C R I P T I O N V E R S I O N P V - 1 5 P R O J E C T N A M E U R 1 0 / 3 0 / 2 0 2 0 I N I T I A L R E L E A S E RON CALL 39 NORTH HIDDEN VALLEY RD, REXBURG, ID 83440 USA APN# RPRHDVY0000060 UTILITY: PACIFICORP AHJ: CITY OF REXBURG B E L L O S O L A R 3 4 6 3 M A G I C D R , S U I T E 2 0 0 3 S A N A N T O N I O , T X , 7 8 2 2 9 T E L : ( 8 0 1 ) 9 8 9 - 3 5 8 5 E m a i l : d e s i g n @ b e l l o s o l a r . c o m S P E C S H E E T S R E V S H E E T N A M E S H E E T N U M B E R D A T E D E S C R I P T I O N V E R S I O N P V - 1 6 P R O J E C T N A M E U R 1 0 / 3 0 / 2 0 2 0 I N I T I A L R E L E A S E RON CALL 39 NORTH HIDDEN VALLEY RD, REXBURG, ID 83440 USA APN# RPRHDVY0000060 UTILITY: PACIFICORP AHJ: CITY OF REXBURG B E L L O S O L A R 3 4 6 3 M A G I C D R , S U I T E 2 0 0 3 S A N A N T O N I O , T X , 7 8 2 2 9 T E L : ( 8 0 1 ) 9 8 9 - 3 5 8 5 E m a i l : d e s i g n @ b e l l o s o l a r . c o m S P E C S H E E T S R E V S H E E T N A M E S H E E T N U M B E R D A T E D E S C R I P T I O N V E R S I O N P V - 1 7 P R O J E C T N A M E U R 1 0 / 3 0 / 2 0 2 0 I N I T I A L R E L E A S E RON CALL 39 NORTH HIDDEN VALLEY RD, REXBURG, ID 83440 USA APN# RPRHDVY0000060 UTILITY: PACIFICORP AHJ: CITY OF REXBURG B E L L O S O L A R 3 4 6 3 M A G I C D R , S U I T E 2 0 0 3 S A N A N T O N I O , T X , 7 8 2 2 9 T E L : ( 8 0 1 ) 9 8 9 - 3 5 8 5 E m a i l : d e s i g n @ b e l l o s o l a r . c o m S P E C S H E E T S