Loading...
HomeMy WebLinkAboutDENSITY SOIL TEST - 2-10-2022File Name: 22-204BD02102022BB PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. b8bc23e67404a7c5-1644513181409 1 4103 E. 605 N. Suite. 1 Rigby ID, 83442 208.881.0081 www.connectengr.com In Place Density of Soils ASTM D2922 & D3017 Project Number: 22-204B Contractor: Edstrom Construction Project Name: Evo Automation Instrument ID 76561 Daily Standardization: Client: Edstrom Construction Date: 02/10/2022 MS: 772 DS: 2802 Time Start: 10:00 AM Time End: 12:30 PM Details Test #: Location:Elevation: Depth:Wet:Dry:% M:Proctor #:% Proctor: Pass Fail 1 Southeast corner of building pad Approximately 2' above water table 10 133.5 129.7 2.9 132.6 Material Type Native Material 98 2 Southwest corner of building pad Approximately 2' above water table 10 130.7 126.5 3.4 132.6 Material Type Native Material 95 3 South wall of building pad Approximately 2' above water table 10 134.1 130.4 2.8 132.6 Material Type Native Material 98 4 South wall of building pad Approximately 2' above water table 10 133.4 128.8 3.6 132.6 Material Type Native Material 97 5 West wall of building pad Approximately 2' above water table 10 130.1 125.9 3.3 132.6 Material Type Native Material 95 File Name: 22-204BD02102022BB PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. b8bc23e67404a7c5-1644513181409 2 Observations/Remarks: Checking densities on native materials in building pad Ambient temperature was 24 degrees Tested By: Ben E. Ball Signature: Reviewed By: E. Vail Signature: Date: 02/15/2022 Inspection Images: File Name: 22-204BD02102022BB PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. b8bc23e67404a7c5-1644513181409 3