HomeMy WebLinkAboutFLOOR PLAN - 22-00609 - 1158 Stone Dr - New SFRB2
4
R
SB36 ChefSeries Dishwasher
B2
4
R
B26
SB
3
0
2
2
B2
4
R
B2
4
R
B24R SB24R
SB
3
2
SB24R
B2
4
R
SB36 ChefSeries Dishwasher
B2
4
R
B26
SB
3
0
2
2
B2
4
R
B2
4
R
B24R SB24R
SB
3
2
SB24R
WH
OPTIONAL
FIREPLACE
30683050SH3050SH
2668
2830RS 3068 4050RS
908016080
40
1
0
R
S
28
3
0
S
H
30
6
8
40
4
0
L
S
2830SH 3030SH 5040RS
3068
26
6
8
2468
26
6
8
2668
2668
2668
UP
4x4 Post 4x4 Post
23'-0" X 5'-7"
5'
-
1
0
"
X
8
'
-
0
"
36'-0" X 26'-6"
18'-1" X 16'-0"
13'-8" X 12'-0"
8'-2" X 7'-6"
6'-2" X 4'-2"
6'
6'-2"
2'
2'2'6'-2"
4'
-
6
"
1'
-
8
"
2'
4'
12
'
13
'
6'
-
4
"
4'
6'
-
6
"
2'
-
4
"
3'
-
8
"
6'
7'-6"4'-5 1/2"
4'
32'
12
'
-
7
1
/
2
"
4'
6'
-
4
"
8'
26
'
-
5
1
/
2
"
4'
11'-6"3'2"3'5'-4"
4'
13
'
-
4
1
/
2
"
1'
-
6
"
4'
1'
-
9
"
2'
-
8
"
3'
-
6
1
/
2
"
3'
6'
-
2
"
1'-9"2'-8"1'-3"1'-9"3'1'-5"4'-10"5'4'-4"6'-6 1/2"4'-5 1/2"5'-11"2'-8"2'-8"3'2'-4 1/2"4'2'-4 1/2"
23'
16'4'9'4'
2'
30
'
8'
40
'
13
'
-
6
"
16
'
-
6
"
60'
37'
4 0 '
27
'
13
'
60'
23'37'
MASTER BDRM
CLOSET
GARAGE
MASTER BATH
PORCH
LA
U
N
D
R
Y
TE
M
P
E
R
E
D
LIVING
VAULTED CEILING WITH HEELS TO
ACHIEVE ADEQUATE PASSAGE AT
STAIR OPENING TO UPPER LEVEL.
VAULT CHORD TO MATCH UPPER TRUSS CHORD.
FLAT 9' CEILING FLAT 9' CEILING
MAIN LEVEL
DN
SB
2
4
R
B2
4
R
SB
2
4
R
B2
4
R
3036DH
40
4
0
R
S
40
4
0
R
S
2668
2668
26
6
8
2668
5068
3036SH
26
6
8
13'-3" X 16'-0"
13'-6" X 24'-10"
12'-2" X 10'-5"
15'-4" X 4'-11"
4'-2" X 4'-10"
6'-4" X 3'-0"
7'-10" X 9'-9"
4'-4" X 6'-6"
4'
4'
7'
2'-10"3'
4'
-
1
0
"
5'
-
9
"
6'-8"
9'6'8'6'8'
8'
-
1
1
"
5'
-
3
"
4'
-
4
"
7'
-
1
"
37'
6'-4"6'-8"8'-2"15'-10"
11
'
14
'
-
7
"
5'
-
4
"
4'
1'
-
8
"
4'
-
5
"
4'
6'
-
2
"
37'
18'-6"5'-0 15/16"13'-5 1/16"
BEDROOM
CLOSETSTORAGEBATH
BEDROOM
FAMILY
CLOSET
MECH.
UPPER LEVEL (BONUS)
1 1/8" OSB TREAD
HANDRAIL PER R311.7.7
7/8" SHTG.
FLOOR JOIST
(3) 2X12 STRINGERS
VERIFY RISE AND RUN
PRIOR TO CONST. FOR
EXACT STAIR LAYOUT
STAIR SECTION
PER R311.7 (IRC 2012)
2X4 WALL (TYP)
1/4" = 1'
3
SHEET:
SCALE:
LO
T
2
1
B
L
O
C
K
1
FO
U
N
D
E
R
S
S
Q
U
A
R
E
S
U
B
D
I
V
I
S
I
O
N
CO
N
T
A
C
T
:
J
A
C
O
B
L
E
W
I
S
2
0
8
-
3
5
3
-
5
4
1
3
DATE:
FLOOR PLAN
SCALE: 1/4" = 1'0"
Handrails shall be provided on at least one side of each
continuous run of treads or flight with four or more risers
and be not less than 34 inches, nor greater than 38
inches, in height as measured from the sloped plane.
Handrails shall be continuous and have a space of not
less than 1 1/2 inch between wall and rail. See
exceptions. (R311.7.8)
HEADER NOTE:
1. ALL LOAD BEARING HEADERS TO BE 4x8 / (2) 2x8 MIN. U.N.O.
2. ALL MAIN FLOOR EXTERIOR WINDOW HEADERS AT 6'-8" A.F.F. U.N.O.
3. ALL MAIN FLOOR INTERIOR HEADERS HEIGHTS TO BE FRAMED AT 6'-8"
A.F.F. (TO BOTTOM OF HEADER) U.N.O.
4. ALL UPPER FLOOR EXTERIOR WINDOW HEADERS TO BE FRAMED AT 6'-8"
A.F.F. (TO BOTTOM OF HEADER) U.N.O.
5. ALL UPPER FLOOR INTERIOR HEADER HEIGHTS TO BE FRAMED AT 6'-8"
A.F.F. (TO BOTTOM OF HEADER) U.N.O.
FRAMING NOTES:
1. 2 X 6 EXTERIOR FRAMING W/ DOUBLE TOP PLATE AND SINGE
BOTTOM PLATE
* ANY BEARING WALL OVER 10' HIGH TO BE 2 X 6
* 2 X 4 INTERIOR FRAMING (TYPICAL)
2. 4 X 8 HEADERS AT ALL OPENINGS IN BEARING WALLS U.N.O.
3. ALL STRUCTURAL LUMBER SIZED FOR NO. 2 OR BETTER DOUGLAS
FIR / LARCH
4. BLOCK WALLS OVER 10'-0" AT MID HEIGHT.
5. ALL FRAMING CONNECTORS TO BE SIMPSON STRONG-TIE OR EQUAL
6. PROVIDE BLOCKING BETWEEN JOISTS AT SPAN PER MFR.
RECOMMENDATIONS AND AT BEARING.
7. COORDINATE ANY NEWLY ESTABLISHED POINT LOADS (NOT
DESIGNED FOR) AS CREATED FROM THE FLOOR JOIST OR TRUSS
PROVIDER WITH THE DESIGNER PRIOR TO POURING FOUNDATION.
8. DESIGNER IS NOT A LICENSED ENGINEER AND WILL CLAIM NO
RESPONSIBILITY FOR STRUCTURAL ITEMS -- ALL LOADING RELATED
DESIGN SHOULD BE VERIFIED WITH A LICENSED ENGINEER PRIOR TO
CONSTRUCTION.
8/16/2022