Loading...
HomeMy WebLinkAboutFLOOR PLAN - 22-00609 - 1158 Stone Dr - New SFRB2 4 R SB36 ChefSeries Dishwasher B2 4 R B26 SB 3 0 2 2 B2 4 R B2 4 R B24R SB24R SB 3 2 SB24R B2 4 R SB36 ChefSeries Dishwasher B2 4 R B26 SB 3 0 2 2 B2 4 R B2 4 R B24R SB24R SB 3 2 SB24R WH OPTIONAL FIREPLACE 30683050SH3050SH 2668 2830RS 3068 4050RS 908016080 40 1 0 R S 28 3 0 S H 30 6 8 40 4 0 L S 2830SH 3030SH 5040RS 3068 26 6 8 2468 26 6 8 2668 2668 2668 UP 4x4 Post 4x4 Post 23'-0" X 5'-7" 5' - 1 0 " X 8 ' - 0 " 36'-0" X 26'-6" 18'-1" X 16'-0" 13'-8" X 12'-0" 8'-2" X 7'-6" 6'-2" X 4'-2" 6' 6'-2" 2' 2'2'6'-2" 4' - 6 " 1' - 8 " 2' 4' 12 ' 13 ' 6' - 4 " 4' 6' - 6 " 2' - 4 " 3' - 8 " 6' 7'-6"4'-5 1/2" 4' 32' 12 ' - 7 1 / 2 " 4' 6' - 4 " 8' 26 ' - 5 1 / 2 " 4' 11'-6"3'2"3'5'-4" 4' 13 ' - 4 1 / 2 " 1' - 6 " 4' 1' - 9 " 2' - 8 " 3' - 6 1 / 2 " 3' 6' - 2 " 1'-9"2'-8"1'-3"1'-9"3'1'-5"4'-10"5'4'-4"6'-6 1/2"4'-5 1/2"5'-11"2'-8"2'-8"3'2'-4 1/2"4'2'-4 1/2" 23' 16'4'9'4' 2' 30 ' 8' 40 ' 13 ' - 6 " 16 ' - 6 " 60' 37' 4 0 ' 27 ' 13 ' 60' 23'37' MASTER BDRM CLOSET GARAGE MASTER BATH PORCH LA U N D R Y TE M P E R E D LIVING VAULTED CEILING WITH HEELS TO ACHIEVE ADEQUATE PASSAGE AT STAIR OPENING TO UPPER LEVEL. VAULT CHORD TO MATCH UPPER TRUSS CHORD. FLAT 9' CEILING FLAT 9' CEILING MAIN LEVEL DN SB 2 4 R B2 4 R SB 2 4 R B2 4 R 3036DH 40 4 0 R S 40 4 0 R S 2668 2668 26 6 8 2668 5068 3036SH 26 6 8 13'-3" X 16'-0" 13'-6" X 24'-10" 12'-2" X 10'-5" 15'-4" X 4'-11" 4'-2" X 4'-10" 6'-4" X 3'-0" 7'-10" X 9'-9" 4'-4" X 6'-6" 4' 4' 7' 2'-10"3' 4' - 1 0 " 5' - 9 " 6'-8" 9'6'8'6'8' 8' - 1 1 " 5' - 3 " 4' - 4 " 7' - 1 " 37' 6'-4"6'-8"8'-2"15'-10" 11 ' 14 ' - 7 " 5' - 4 " 4' 1' - 8 " 4' - 5 " 4' 6' - 2 " 37' 18'-6"5'-0 15/16"13'-5 1/16" BEDROOM CLOSETSTORAGEBATH BEDROOM FAMILY CLOSET MECH. UPPER LEVEL (BONUS) 1 1/8" OSB TREAD HANDRAIL PER R311.7.7 7/8" SHTG. FLOOR JOIST (3) 2X12 STRINGERS VERIFY RISE AND RUN PRIOR TO CONST. FOR EXACT STAIR LAYOUT STAIR SECTION PER R311.7 (IRC 2012) 2X4 WALL (TYP) 1/4" = 1' 3 SHEET: SCALE: LO T 2 1 B L O C K 1 FO U N D E R S S Q U A R E S U B D I V I S I O N CO N T A C T : J A C O B L E W I S 2 0 8 - 3 5 3 - 5 4 1 3 DATE: FLOOR PLAN SCALE: 1/4" = 1'0" Handrails shall be provided on at least one side of each continuous run of treads or flight with four or more risers and be not less than 34 inches, nor greater than 38 inches, in height as measured from the sloped plane. Handrails shall be continuous and have a space of not less than 1 1/2 inch between wall and rail. See exceptions. (R311.7.8) HEADER NOTE: 1. ALL LOAD BEARING HEADERS TO BE 4x8 / (2) 2x8 MIN. U.N.O. 2. ALL MAIN FLOOR EXTERIOR WINDOW HEADERS AT 6'-8" A.F.F. U.N.O. 3. ALL MAIN FLOOR INTERIOR HEADERS HEIGHTS TO BE FRAMED AT 6'-8" A.F.F. (TO BOTTOM OF HEADER) U.N.O. 4. ALL UPPER FLOOR EXTERIOR WINDOW HEADERS TO BE FRAMED AT 6'-8" A.F.F. (TO BOTTOM OF HEADER) U.N.O. 5. ALL UPPER FLOOR INTERIOR HEADER HEIGHTS TO BE FRAMED AT 6'-8" A.F.F. (TO BOTTOM OF HEADER) U.N.O. FRAMING NOTES: 1. 2 X 6 EXTERIOR FRAMING W/ DOUBLE TOP PLATE AND SINGE BOTTOM PLATE * ANY BEARING WALL OVER 10' HIGH TO BE 2 X 6 * 2 X 4 INTERIOR FRAMING (TYPICAL) 2. 4 X 8 HEADERS AT ALL OPENINGS IN BEARING WALLS U.N.O. 3. ALL STRUCTURAL LUMBER SIZED FOR NO. 2 OR BETTER DOUGLAS FIR / LARCH 4. BLOCK WALLS OVER 10'-0" AT MID HEIGHT. 5. ALL FRAMING CONNECTORS TO BE SIMPSON STRONG-TIE OR EQUAL 6. PROVIDE BLOCKING BETWEEN JOISTS AT SPAN PER MFR. RECOMMENDATIONS AND AT BEARING. 7. COORDINATE ANY NEWLY ESTABLISHED POINT LOADS (NOT DESIGNED FOR) AS CREATED FROM THE FLOOR JOIST OR TRUSS PROVIDER WITH THE DESIGNER PRIOR TO POURING FOUNDATION. 8. DESIGNER IS NOT A LICENSED ENGINEER AND WILL CLAIM NO RESPONSIBILITY FOR STRUCTURAL ITEMS -- ALL LOADING RELATED DESIGN SHOULD BE VERIFIED WITH A LICENSED ENGINEER PRIOR TO CONSTRUCTION. 8/16/2022