HomeMy WebLinkAboutAPPROVED STRUCTURAL ENGINEERING - 21-00342 - Teton Lakes Golf Course - Solar PanelsAuthor Name Author Email Author Phone No.: Cody Jones Cody.Jones@rexburg.org 208-372-2173 Description : Teton Lakes Golf Course - Solar Panels Address : 722 N 12th W Record Type : Solar Panels Document Filename : Teton Lakes Golf Course Roof Evaluation.pdf Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Approved # 21-00342 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments Pg 1 Stamp Cody Jones : Building Open 1 Approved - Building Inspector Pg 1 Rectangle Cody Jones : Building Open 1 Solar Panels Approval of plans does not constitute approval of variance from code 55 WEST 500 SOUTH, HEBER CITY, UT 84032 T 925.787.3067 U RIGHTANGLEENG.COM May 5, 2021 Horizon PWR 166 Valley Street Providence, RI 02909 RE: Structural Roof Evaluation for the Teton Lakes Golf Course: 722 North 12th West, Rexburg, Idaho As per your request, we have evaluated the roof structure under the proposed solar panel array. The information used to evaluate this structure was gathered by Horizon PWR on behalf of Right Angle Engineering. The roof structure consists of 4x10 rafters spaced at 69” on center. The roof material consists of asphalt shingles. The design criteria used to analyze this structure are listed above and included with this letter. The adopted building codes in this jurisdiction are: the 2018 International Building Code, the 2018 International Existing Building Code, and ASCE 7-16. International Existing Building Code (IEBC) 2018 section 806.2 indicates that alterations to an existing building that results in less than a 5% increase in the total stress may be performed without a structural evaluation of the existing building. As demonstrated in the attached calculations, the additional weight of the solar panels will be less than 5% increase in the gravity loading and the stress on the existing roof framing. Based on our assessment we have determined that the existing roof framing will safely and adequately support the additional loads imposed by the solar panels without reinforcement. In order for the loads to be evenly distributed, the roof attachments should be staggered and spread evenly throughout the panel array. Attachment points should be spaced at a maximum of 48” on center. The racking system should be installed per the manufacture’s specifications. There should be a minimum of 109 Unirac Flashloc attachment points to the roof. Each attachment should have a 5/16” or 18/8 SS lag screw with 2.5” minimum penetration centered on each truss top chord or rafter. Waterproofing around the roof penetrations is the responsibility of others. Right Angle Engineering assumes no responsibility for improper installation of the solar panels. Regards, Robert D Smythe, P.E. Right Angle Engineering 5/5/21 Design Criteria: Design Wind Speed (ASD)- 115 mph Ground Snow Load- 50 psf Risk Category- II Exposure category- C 2 Design Criteria: Design Wind Speed (3 second gust) 115 mph Exposure Category C Risk Category 2 Mean Roof Height 30 ft Roof Type Gable Roof Building Type enclosed Roof Dead Load- ASCE Table C3-1 Asphalt Shingles 2 psf 5/8" Plywood Sheathing 2 psf Roof Framing 4 psf Insulation 3.85 psf Gypsum sheathing 2 psf Solar Panel Array 3 psf Dead Load Without Panels 13.85 psf Dead Load With Solar panels 16.85 psf Roof Live Load Existing Roof Live Load 20 psf ASCE 7-16 Table 4.3-1 Roof Live Load with Solar Panels 0 psf 2018 IBC 1607.13.5.1 Roof Snow Load-ASCE 7-16 Ground Snow Load (pg) 50 psf Section 7.2 Exposure Factor (Ce) 0.9 Table 7.3-1 Thermal Factor (Ct) 1.1 Table 7.3-2 Importance Factor (Is) 1 Table 1.5-2 Flat Roof Snow Load (Pf) 35 Equation 7.3-1 Slippery surface Slope Factor (Cs) 0.67 Figure 7-2 Nonslippery Surface Slope Factor (Cs) 1 Figure 7-2 Roof Snow Load 35 psf Equation 7.4-1 Reduced Roof Snow Load (Slippery Surface) 23 psf Equation 7.4-1 Load Combinations - ASCE 7-16 Section 2.4.1 Without Solar Panels With Solar panels D + Lr 33.8 psf 16.8 psf D + S 48.5 psf 40 psf 3 Solar Array 1- North Roof Slope 30 degrees Number of panels 22 Panel Area 385 ft^2 Wind Calculations- ASCE 7-16 GCp Zone 1 -1 Figure 30.3-(2A-5B) GCp Zone 2 -1.8 Figure 30.3-(2A-5B) GCp Zone 3 -2.8 Figure 30.3-(2A-5B) Gcpi 0.18 Table 26.13-1 Velocity Pressure (qh) 28.2 psf qh= .00256KhKhtKdV^2 Equation 26.10-1 Kh 0.98 Table 26.10-1 Kht 1 Equation 26.8-1 Kd 0.85 Table 26.6-1 Designed wind pressure (P) psf Equation 30.8-1 P= qh(GCh) - (GChi)) Zone 1 Pressure (P) -33.3 psf Zone 2 Pressure (P) -55.8 psf Zone 3 Pressure (P) -84 psf Roof Connection Shear Capacity 190 lbs NDS 2015 Table 12K Shear tributary area 14.6 ft^2 Pullout Capacity 266 lbs/in Lag screw embedment 2.5 in Total pullout capacity 665 lbs NDS 2015 Table 12.2A Pullout max tributary area 11.9 ft^2 Factor of Safety 1.41 Minimum number of connections 37 Beam Stress IEBC 2018 Section 806.2 Beam Span 16 ft Spacing 5.75 ft Roof Framing type 4x10 rafters Panel Orientation portrait Number of Panels per rafter 3 Panel distance from eave 3 Without Solar Panels With Solar Panels Percent Increase Bending Moment 8924 ft-lbs 5465.6 ft-lbs 61.2% Less than 105% Vertical Reaction (V1) 2231 lbs 1582.7 lbs 70.9% Less than 105% Vertical Reaction (V2) 2231 lbs 463.59 lbs 20.8% Less than 105% 4 Solar Array 2- South Roof Slope 30 degrees Number of panels 45 Panel Area 787.5 ft^2 Wind Calculations- ASCE 7-16 GCp Zone 1 -1 Figure 30.3-(2A-5B) GCp Zone 2 -1.2 Figure 30.3-(2A-5B) GCp Zone 3 -1.2 Figure 30.3-(2A-5B) Gcpi 0.18 Table 26.13-1 Velocity Pressure (qh) 28.2 psf qh= .00256KhKhtKdV^2 Equation 26.10-1 Kh 0.98 Table 26.10-1 Kht 1 Equation 26.8-1 Kd 0.85 Table 26.6-1 Designed wind pressure (P) psf Equation 30.8-1 P= qh(GCh) - (GChi)) Zone 1 Pressure (P) -33.3 psf Zone 2 Pressure (P) -38.9 psf Zone 3 Pressure (P) -38.9 psf Lag Screw Connection Shear Capacity 190 lbs NDS 2015 Table 12K Shear tributary area 14.6 ft^2 Pullout Capacity 266 lbs/in Lag screw embedment 2.5 in Total pullout capacity 665 lbs NDS 2015 Table 12.2A Pullout max tributary area 17.1 ft^2 Factor of Safety 1.91 Minimum number of connections 72 Beam Stress IEBC 2018 Section 806.2 Beam Span 27 ft Spacing 5.75 ft Roof Framing type 4x10 rafters Panel Orientation portrait Number of Panels per rafter 5 Panel distance from eave 0 Without Solar Panels With Solar Panels Percent Increase Bending Moment 25412.5 ft-lbs 12017.7 ft- lbs 47.3% Less than 105% Vertical Reaction (V1) 3764.8 lbs 1874.2 lbs 49.8% Less than 105% Vertical Reaction (V2) 3764.8 lbs 1681.9 lbs 44.7% Less than 105%