HomeMy WebLinkAboutAPPROVED PLANS - 21-00523 - 905 Oak Hill Way - New SFRAuthor Name Author Email Author Phone No.: Larry Beesley Larry.Beesley@rexburg.org 208-372-2176 Description : 905 Oak Hill Way - New SFR Address : Record Type : New Single Family Residence Document Filename : 15212-matthew-astin-final.pdf Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Approved # 21-00523 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments Pg 1 Stamp Larry Beesley : Building Open 1 Approved - Building Inspector Pg 2 Stamp Larry Beesley : Building Open 2 Approved - Building Inspector Pg 2 Free text Larry Beesley : Building Open 2 Street Number Displayed on House Pg 2 Free text Larry Beesley : Building Open 2 Roof Ventilation as per R806 Pg 2 Free text Larry Beesley : Building Open 2 Roof Trusses (designed according to R802.10.1) 35 # Snow and 90 mph winds (Local Conditions) Pg 2 Free text Larry Beesley : Building Open 2 Ground Surface to Slope away from Foundation a minimum of 6" within first 10 ft. Pg 3 Stamp Larry Beesley : Building Open 3 Approved - Building Inspector Pg 3 Free text Larry Beesley : Building Open 3 Roof Ventilation as per R806 Pg 3 Free text Larry Beesley : Building Open 3 Roof Trusses (designed according to R802.10.1) 35 # Snow and 90 mph winds (Local Conditions) Pg 3 Free text Larry Beesley : Building Open 3 Ground Surface to Slope away from Foundation a minimum of 6" within first 10 ft. Pg 4 Stamp Larry Beesley : Building Open 4 Approved - Building Inspector New Single Family Residence Approval of plans does not constitute approval of variance from code Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments Pg 4 Free text Larry Beesley : Building Open 4 Ufer Ground Pg 4 Line Larry Beesley : Building Open 4 Pg 4 Free text Larry Beesley : Building Open 4 Provide rebar specks for all footings and walls. Pg 4 Free text Larry Beesley : Building Open 4 See the rebar speck sheet. Pg 5 Stamp Larry Beesley : Building Open 5 Approved - Building Inspector Pg 6 Stamp Larry Beesley : Building Open 6 Approved - Building Inspector Pg 6 Free text Larry Beesley : Building Open 6 CO SD Pg 6 Line Larry Beesley : Building Open 6 Pg 7 Stamp Larry Beesley : Building Open 7 Approved - Building Inspector Pg 7 Free text Larry Beesley : Building Open 7 Roof Trusses (designed according to R802.10.1) 35 # Snow and 90 mph winds (Local Conditions) Pg 7 Free text Larry Beesley : Building Open 7 Room access 36" min width/Attic access clear opening 20x30/Under floor r.o 22x30 M 306.2; 306.3 & 306.4 Pg 8 Stamp Larry Beesley : Building Open 8 Approved - Building Inspector Pg 8 Free text Larry Beesley : Building Open 8 Roof Trusses (designed according to R802.10.1) 35 # Snow and 90 mph winds (Local Conditions) Approval of plans does not constitute approval of variance from code Powered by TCPDF (www.tcpdf.org)