Loading...
HomeMy WebLinkAboutAPPROVED PLANS - 21-00880 - Madison Memorial Hospital - MRI Zone RemodelAuthor Name Author Email Author Phone No.: Kyle Baldwin Kyle.Baldwin@rexburg.org 208-372-2164 Alex Owens Alex.Owens@rexburg.org 208-372-2330 Cody Jones Cody.Jones@rexburg.org 208-372-2173 Description : Madison Memorial Hospital - MRI Zone Remodel Address : 450 E Main St Record Type : Commercial - Remodel Document Filename : MMH MRI Renovations - BID SET 10.28.21.pdf Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Approved # 21-00880 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments G100 Stamp Cody Jones : Building Open 1 Approved - Building Inspector A100 Free text Cody Jones : Building Open 2 All construction and materials need to comply with IBC 2018. Exit lighting and Emergency lighting to be installed. Ceiling to be installed to manufactures specifications. G100 Stamp Alex Owens : Electrical Open 1 Approved - Electrical Inspector E000 Callout Alex Owens : Electrical Open 3 All wiring must meet 2017 NEC requirements E000 Stamp Alex Owens : Electrical Open 3 Approved - Electrical Inspector E100 Stamp Alex Owens : Electrical Open 4 Approved - Electrical Inspector G100 Stamp Kyle Baldwin : P&Z Open 1 Approved - Planning and Zoning A100 Stamp Kyle Baldwin : P&Z Open 2 Approved - Planning and Zoning E000 Stamp Kyle Baldwin : P&Z Open 3 Approved - Planning and Zoning E100 Stamp Kyle Baldwin : P&Z Open 4 Approved - Planning and Zoning Commercial - Remodel Approval of plans does not constitute approval of variance from code Powered by TCPDF (www.tcpdf.org) GSPublisherVersion 1169.55.55.100 TITLE SHEET G100 B. LEDFORD SHEET TITLE: JOBNUMBER: REVISION DATE RE X B U R G , ID PR O J E C T : CONTRACTOR SHALL VERIFY ALL DIMENSIONS & CONDITIONS SHOWN OR IMPLIED 21553-21B OCTOBER 2021 M y e r s 92 7 Ma i n St r e e t , Su i t e 30 0 ■ Ev a n s t o n , Wy o m i n g 82 9 3 0 ■ Te l . (30 7 ) 78 9 - 09 3 4 12 2 So u t h Ma i n St r e e t ■ Po c a t e l l o , Id a h o 83 2 0 4 ■ Te l . (20 8 ) 23 2 - 37 4 1 ■ Fa x (20 8 ) 23 2 - 37 8 2 AI A NC A R B AS I D DRAWNBY: PROJECTDATE: SHEET MR I ZO N E S DRAWING SCALE APPLIES TO22" X 34" SHEET SIZE ■ Ar c h i t e c t u r e A n d e r s o n ■ In t e r i o r De s i g n ■ Hi s t o r i c Pr e s e r v a t i o n MA D I S O N ME M O R I A L HO S P I T A L MRI ZONES CONSULTANTSABBREVIATIONS ELECTRICAL ENGINEER MUSGROVE ENGINEERING 645 W. 25TH ST. IDAHO FALLS, ID 83402 PHONE: (208) 523-2862 FAX: (208) 523-2864 CONCRETE BLOCK STRUCTURAL WOOD DEMO RIGID INSULATION BRICK VENEER GRAVEL SYMBOLS METAL STUDS CONCRETE GYP. WALL BD. WOOD STUDS EARTH DRAWING NUMBER TITLE DETAIL NUMBER DETAIL SYMBOL SECTION LETTER BUILDING SECTION SHEET NUMBER ELEVATION WINDOW MARKER ROOM NUMBER DOOR NUMBER DETAIL NUMBER DETAIL CUT SHEET NUMBER WALL ELEVATION ELEVATION NUMBER BATT INSULATION SHEET NUMBER SHEET NUMBER SECTION NUMBER WALL SECTION SHEET NUMBER FILL EARTH EXISTING METAL 3/4" = 1'-0" J A300 SHEET NUMBER ELEVATION NUMBER BUILDING ELEVATION SHEET NUMBER DRAWING INDEX SHEET NUMBER SHEET TITLE G100 COVER SHEET A100 ARCHITECTURAL DRAWINGS E000 ELECTRICAL COVER SHEET E100 POWER PLAN VICINITY MAP CODE REVIEW RENOVATION IS LIMITED IN SCOPE AND DOES NOT AFFECT USE OR CONSTRUCTION TYPE. THE COMMENTS BELOW ARE INTENDED TO ADDRESS POTENTIAL QUESTIONS THAT MAY ARISE IN REVIEW. 1. RENOVATION ADDS NO AREA TO EXISTING BUILDING. 2. RENOVATION CLOSES OFF AN EXISTING HALLWAY BUT THE DEAD-END HALLWAY CREATED IS ONLY 15' LONG. 3. THE HALLWAY THAT IS BEING CLOSED IS NOT A REQUIRED SECOND PATH OF EGRESS FOR ANY AREA OF THE HOSPITAL. 4. NEW WALLS BEING ADDED ARE NOT FIRE OR SMOKE PARTITIONS. NO EXISTING FIRE OR SMOKE PARTITIONS ARE AFFECTED. 5. EXISTING FIRE SPRINKLER HEADS WILL NOT BE AFFECTED AND WILL CONTINUE TO PROVIDE COVERAGE TO ALL AREAS IN THE RENOVATION. ARCH ARCHITECTURAL CLG. CEILING ELEC. ELECTRICAL EQ. EQUAL EXIST. EXISTING GYP. BRD. GYPSUM BOARD HM HOLLOW METAL HORIZ HORIZONTAL MECH. MECHANICAL O.C. ON CENTER TYP. TYPICAL VERT VERTICAL WD WOOD PROJECT LOCATION 450 E MAIN ST, REXBURG, ID 83440 155 W03 4 A501 A300 A202 5/A300 2/SD102 #DrgID #DrgID #DrgID #DrgID #DrgID #LayID WALL TYPE3 PLYWOOD WOOD BLOCKING PROJECT SITE B B ROOM NAME 146 43 sq ft OVERALL MAIN LEVEL PLAN 1/32" = 1'-0" PROJECT LOCATION GSPublisherVersion 1169.55.55.100 ARCH.DRAWINGS A100 B. LEDFORD SHEET TITLE: JOBNUMBER: REVISION DATE RE X B U R G , ID PR O J E C T : CONTRACTOR SHALL VERIFY ALL DIMENSIONS & CONDITIONS SHOWN OR IMPLIED 21553-21B OCTOBER 2021 M y e r s 92 7 Ma i n St r e e t , Su i t e 30 0 ■ Ev a n s t o n , Wy o m i n g 82 9 3 0 ■ Te l . (30 7 ) 78 9 - 09 3 4 12 2 So u t h Ma i n St r e e t ■ Po c a t e l l o , Id a h o 83 2 0 4 ■ Te l . (20 8 ) 23 2 - 37 4 1 ■ Fa x (20 8 ) 23 2 - 37 8 2 AI A NC A R B AS I D DRAWNBY: PROJECTDATE: SHEET MR I ZO N E S DRAWING SCALE APPLIES TO22" X 34" SHEET SIZE ■ Ar c h i t e c t u r e A n d e r s o n ■ In t e r i o r De s i g n ■ Hi s t o r i c Pr e s e r v a t i o n MA D I S O N ME M O R I A L HO S P I T A L MRI (ZONE 4) --- A:469 sq ft MRI/CT CONTROL --- A:309 sq ft CT --- A:386 sq ft PAT. RR. --- A:39 sq ft XRAY 2 --- A:324 sq ft XRAY 1 --- A:417 sq ft PAT. RR. --- A:43 sq ft JAN. --- A:35 sq ft DRESSING RM --- A:39 sq ft ZONE 2 100 A:204 sq ft ZONE 3 101 A:204 sq ft HALLWAY (ZONE 1) --- A:853 sq ft 100 101 15 ' - 0 " ALIGN WALL WITH CORNER CUT WALL BUMPER BACK 6" FROM EACH SIDE OF NEW DOOR FRAMES AND INSTALL NEW END CAPS, TYP. SINGLE/PAIR PAIR DOOR WIDTH 7'-7" HEIGHT 7'-0" THK 1 3/4" MAT FLUSH WOOD VENEER RED OAK, CLEAR FINISH FRAME MAT HOLLOW METAL THROAT 4 7/8" GLAZING TYPE 1/4" TEMPERED HINGES IVES 112HD, CONT. HINGE KICKPLATE IVES 8400 SERIES LOCK ASSA ABLOY, M32 LEVER SCHALGE ND SERIES EXIT DEVICE VON DUPRIN, 98 SERIES OPERATORS NORTON 6050 689 ADA ACTUATOR NORTON 502 STOPS ROCKWOOD 406 US32D CARD READER MATCH EXISTING REQUEST TO EXIT MATCH EXISTING POWER TRANSFER SECURITRON POWER SUPPLY SECURITRON DOOR 100 FUNCTION: CARD IN. USER PRESENTS CREDENTIAL, MAG LOCK RELEASES AND OPERATOR OPENS ACTIVE LEAF. REQUEST TO EXIT IS IN ADA ACTUATOR AND IN EXIT DEVICE FOR LEFT HAND LEAF. 7' - 0 " 3'-9 1/2"3'-9 1/2" 8'-0" 1' - 4 " 8"8" 2' - 6 " 1' - 0 " UNDERCUT DOORS 1" SINGLE/PAIR PAIR, UNEQUAL LEAVES, AS SHOWN DOOR WIDTH 7'-0" HEIGHT 7'-0" THK 1 3/4" MAT FLUSH WOOD VENEER RED OAK, CLEAR FINISH FRAME MAT HOLLOW METAL THROAT 4 7/8" GLAZING TYPE 1/4" TEMPERED HINGES IVES 112HD, CONT. HINGE KICKPLATE IVES 8400 SERIES LOCK ASSA ABLOY, M32 LEVER SCHALGE ND SERIES EXIT DEVICE VON DUPRIN, 98 SERIES OPERATORS NORTON 6050 689 ADA ACTUATOR NORTON 502 STOPS ROCKWOOD 406 US32D CARD READER MATCH EXISTING REQUEST TO EXIT MATCH EXISTING POWER TRANSFER SECURITRON POWER SUPPLY SECURITRON DOOR 101 FUNCTION: CARD IN. USER PRESENTS CREDENTIAL, MAG LOCK RELEASES AND OPERATOR OPENS ACTIVE LEAF. REQUEST TO EXIT IS IN ADA ACTUATOR FOR ACTIVE LEAF. REQUEST TO EXIT IS IN EXIT DEVICE FOR INACTIVE LEAF. 1' - 4 " 3'-0"4'-0" 7' - 0 " 2' - 6 " 1' - 0 " 8"8" UNDERCUT DOORS 1" EXIST. MECH. DIFFUSERS EXIST. LIGHT FIXTURES EXIST. SPEAKER EXIST. SPEAKER EXIST. SPRINKLER HEADS CUT AND PATCH EXIST. CLG. GRID TO NEW WALL CUT AND PATCH EXIST. CLG. GRID TO NEW WALL 3" 1/2" 2" 5/8" GYP. BRD. MTL. STUD FRAMING AT 1'-4" O.C. 5/8" GYP. BRD. HOLLOW METAL DOOR FRAME DOOR, SEE DOOR SCHEDULE 3"2" DOOR, SEE DOOR SCHEDULE 5/8" GYP. BRD. SEALANT, BOTH SIDES 5/8" GYP. BRD. MTL. STUD FRAMING AT 1'-4" O.C. HOLLOW METAL DOOR FRAME MAIN FLOOR PLAN 1/8" = 1'-0" DOOR 100 3/8" = 1'-0" DOOR 101 3/8" = 1'-0" MAIN FLOOR REFLECTED CEILING PLAN 1/8" = 1'-0" JAMB DETAIL 1 1/2"= 1'-0" HEAD DETAIL 1 1/2"= 1'-0" All construction and materials need to comply with IBC 2018. Exit lighting and Emergency lighting to be installed. Ceiling to be installed to manufactures specifications. GSPublisherVersion 1169.55.55.100 E000 E100 B. LEDFORD SHEET TITLE: JOBNUMBER: REVISION DATE RE X B U R G , ID PR O J E C T : CONTRACTOR SHALL VERIFY ALL DIMENSIONS & CONDITIONS SHOWN OR IMPLIED 21553-21B OCTOBER 2021 M y e r s 92 7 Ma i n St r e e t , Su i t e 30 0 ■ Ev a n s t o n , Wy o m i n g 82 9 3 0 ■ Te l . (30 7 ) 78 9 - 09 3 4 12 2 So u t h Ma i n St r e e t ■ Po c a t e l l o , Id a h o 83 2 0 4 ■ Te l . (20 8 ) 23 2 - 37 4 1 ■ Fa x (20 8 ) 23 2 - 37 8 2 AI A NC A R B AS I D DRAWNBY: PROJECTDATE: SHEET MR I ZO N E S DRAWING SCALE APPLIES TO22" X 34" SHEET SIZE ■ Ar c h i t e c t u r e A n d e r s o n ■ In t e r i o r De s i g n ■ Hi s t o r i c Pr e s e r v a t i o n MA D I S O N ME M O R I A L HO S P I T A L DUAL LEVEL SWITCHING, INSIDE AND OUTSIDE LAMPS OF FIXTURE TO BE SWITCHED SEPARATELY. SWITCH, TYPE AS INDICATED. +46"AFF SINGLE CONVENIENCE OUTLET, +18" AFF UNO FLOOR MOUNT SINGLE CONVENIENCE OUTLET DUPLEX CONVENIENCE OUTLET, +18" AFF UNO FLOOR MOUNT DUPLEX CONVENIENCE OUTLET EMERGENCY DUPLEX CONVENIENCE OUTLET, +18" AFF UNO SWITCHED DUPLEX CONVENIENCE OUTLET, +18" AFF UNO FLOOR MOUNTED SWITCHED DUPLEX CONVENIENCE OUTLET FOURPLEX CONVENIENCE OUTLET. +18"AFF UNO FLOOR MOUNT FOURPLEX CONVENIENCE OUTLET CONNECTION POINT TO EQUIPMENT SPECIFIED, ELECTRICAL CONTRACTOR TO SUPPLY RACEWAY AND CONDUCTORS AND MAKE FINAL CONNECTION TO EQUIPMENT UNDER THIS SECTION. UNO FLOOR MOUNTED CONNECTION POINT, SEE NOTE ABOVE FOR REQUIREMENTS JUNCTION BOX WALL MOUNTED PUSH BUTTON, MOUNT AT SWITCH HEIGHT UNO WALL MOUNTED PUSH BUTTON, HANDICAPPED MOUNT AT SWITCH HEIGHT UNO WALL MOUNTED PUSH BUTTON, MOUNT AT SWITCH HEIGHT UNO MOTOR STARTER/CONTACTOR, SIZE/POLES NEMA 1 UNO AS INDICATED COMBINATION STARTER AND DISCONNECT, SIZE/POLES, STARTER SIZE AS INDICATED, NEMA 1 UNO MECHANICAL EQUIPMENT CALL OUT SURFACE MULTI-OUTLET RACEWAY EQUIPMENT CABINET FLUSH MOUNTED EQUIPMENT CABINET, SURFACE MOUNTED PANELBOARD. SEE SCHEDULE FOR TYPE. TRANSFORMER POWER POLE - DUAL CHANNEL THERMOSTAT, +46" AFF PROVIDE CONDUIT, J-BOX, CONDUCTORS AS REQUIRED TO CONTROL ASSOCIATED UNITS. UNO COORDINATE WITH DIVISION 15. NON-FUSED DISCONNECT SIZE/ POLES AS INDICATED, NEMA 1 UNO FUSED DISCONNECT SWITCH, SIZE/POLES, FUSE SIZES AS INDICATED, NEMA 1 UNO KITCHEN EQUIPMENT CALLOUT FLOOR MOUNTED JUNCTION BOX # # # # # 2 DOUBLE POLE 3 3-WAY 4 4-WAY K KEYED P PILOT LIGHT D DIMMER HP HORSEPOWER RATED TO THERMAL OVERLOAD LV LOW VOLTAGE OS OCCUPANCY SENSOR OR LOW VOLTAGE, MOMENTARY OVERRIDE VS VACANCY SENSOR a SUPERSCRIPT INDICATES LIGHTS TO BE SWITCHED TOGETHER SX X J J HC F T X-X S S SOS 2 DUAL LEVEL SWITCHING WITH OCCUPANCY SENSOR, INSIDE AND OUTSIDE LAMPS OF FIXTURE TO BE SWITCHED SEPARATELY. DEVICES A AMPERES AC 6" ABOVE BACKSPLASH AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AF AMP FRAME AIC AMPS INTERRUPTING CAPACITY AT AMP TRIP ATS AUTOMATIC TRANSFER SWITCH AWG AMERICAN WIRE GAUGE BD BOTTOM OF DECK BS BOTTOM OF STRUCTURE C CEILING MOUNTED C CONDUIT CB CIRCUIT BREAKER CF COMPACT FLUORESCENT CKT CIRCUIT CO CONDUIT ONLY, PROVIDE PULL-LINE CT CURRENT TRANSFORMER CTL CONTROL DC DIRECT CURRENT (D)DEMOLITION DEMO DEMOLITION DET DETAIL DTT DOUBLE TWIN TUBE E EMERGENCY (E)EXISTING EC ELECTRICAL CONTRACTOR EL EMERGENCY LIGHT F FUSE (F)FUTURE FACP FIRE ALARM CONTROL PANEL G/GND GROUND GFCI GROUND FAULT CIRCUIT INTERRUPTER GFI GROUND FAULT INTERRUPTER HH HAND HOLE HID HIGH INTENSITY DISCHARGE HOA HAND-OFF-AUTO HPS HIGH PRESSURE SODIUM HVAC HEATING, VENTILATION, & AIR CONDITIONING IG ISOLATED GROUND IPCO IDAHO POWER COMPANY J-BOX JUNCTION BOX KA KILOAMP KVA KILO VOLT-AMP KW KILOWATT KWH KILOWATT HOUR LCP LIGHTING CONTROL PANEL MB MAIN BREAKER MBR MAIN CIRCUIT BREAKER MCC MOTOR CONTROL CENTER MDP MAIN DISTRIBUTION PANEL MLO MAIN LUGS ONLY MMC MODULAR METERING CENTER MH METAL HALIDE MSB MAIN SWITCH BOARD MTG MOUNTING N NEUTRAL (N)NEW NC NORMALLY CLOSED NEC NATIONAL ELECTRICAL CODE NIC NOT IN CONTRACT NL NIGHT LIGHT NO NORMALLY OPEN NTS NOT TO SCALE OH OVERHEAD OS OCCUPANCY SENSOR P POLES PC PHOTO-CONTROL PVC POLYVINYL CHLORIDE PWR POWER RE:REFERENCE REC RECEPTACLE (R)RELOCATED SF SQUARE FEET TBD TO BE DETERMINED TDR TIME DELAY RELAY TK TOE KICK TSP TWISTED SHIELDED PAIR TRT TRIPLE TUBE TTB TELEPHONE TERMINAL BOARD (TYP.)TYPICAL UC UNDERCABINET UG UNDERGROUND U.N.O.UNLESS NOTED OTHERWISE V VOLT VA VOLT-AMPERE W WATT WG WIRE GUARD WP WEATHER PROOF/NEMA 3R ELECTRICAL ABBREVIATIONS PROVIDED/ PROVIDE BY INSTALLED/ INSTALL PROVIDE AND INSTALL / PROVIDED AND INSTALLED BY / PROVIDE AND INSTALL NOTE: THIS IS A STANDARD LIST OF COMMONLY USED ELECTRICAL ABBREVIATIONS. SOME OF THE ABBREVIATIONS SHOWN ABOVE MAY NOT BE USED IN THIS DRAWING PACKAGE. NOTE: THIS IS A STANDARD LIST OF COMMONLY USED ELECTRICAL SYMBOLS. SOME OF THE SYMBOLS SHOWN MAY NOT HAVE BEEN USED IN THIS DRAWING PACKAGE. EXISTING CONDUIT DOWN CONDUIT UP 6 NEUTRAL CONDUCTORS GROUNDING CONDUCTOR SIZE QUANTITY 1"-4#10,1#10G PANEL HOMERUN. (3/4"-2#12,1#12G CONDUCTORS UNO) RACEWAY A-2,4,6 PANEL NAME CIRCUIT # EM NOTE: J J J J J J CIRCUITING SYMBOLS CURRENT CARRYING CONDUCTORS T ELECTRICAL SPECIFICATIONS - BLACK - RED - BLUE - WHITE - GREEN PHASE A PHASE B PHASE C NEUTRAL GROUND - BROWN - ORANGE - YELLOW - GRAY - GREEN PHASE A PHASE B PHASE C NEUTRAL GROUND 208Y/120 VOLT SYSTEM 480Y/277 VOLT SYSTEM A.ALL WORK SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE LOCALLY ADOPTED ELECTRICAL CODE, ALL LOCAL CODES, AND TO THE FULL ACCEPTANCE OF THE AUTHORITY HAVING JURISDICTION. B.OBTAIN ALL PERMITS, COORDINATE, FURNISH, INSTALL, CONNECT AND TEST ALL ELECTRICAL EQUIPMENT REQUIRED FOR ALL THE SYSTEMS INSTALLED UNDER THIS CONTRACT TO INSURE COMPLETE AND FULLY OPERATIONAL SYSTEMS. C.CONTRACTOR SHALL MAINTAIN A COMPLETE SET OF AS-BUILT DRAWINGS. AS-BUILT SET OF DRAWINGS SHALL BE UPDATED DAILY AND SHALL DOCUMENT THE ACTUAL INSTALLED CONDITION OF THE ENTIRE ELECTRICAL INSTALLATION. AS-BUILT SET OF DRAWINGS SHALL BE AVAILABLE AT ALL TIMES ON THE SITE FOR INSPECTION BY CODE OFFICIALS, OWNER, ARCHITECT, AND ENGINEER. D.PROTECT ALL EXISTING WORK FROM DAMAGE DURING CONSTRUCTION. E.DESIGN IS BASED ON BEST AVAILABLE INFORMATION. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS TO DETERMINE STATUS OF ACTUAL CONDITIONS AS THEY RELATE TO THE SCOPE OF WORK AS SHOWN ON THESE PLANS. F.COORDINATE ALL ELECTRICAL WORK WITH ALL OTHER TRADES. G.COORDINATE EXACT LOCATION AND MOUNTING HEIGHTS OF ALL ELECTRICAL EQUIPMENT AND DEVICES WITH THE ARCHITECTURAL ELEVATIONS AND DETAILS PRIOR TO ROUGH-IN. H.DEMOLITION WORK IS A PART OF THIS PROJECT. SEE DRAWINGS FOR EXISTING ELECTRICAL DEVICES TO BE REMOVED. REMOVE ASSOCIATED BOXES, RACEWAYS AND CONDUCTORS BACK TO SOURCE, AND MAKE SAFE. I.ALL MATERIALS AND EQUIPMENT FURNISHED TO THE PROJECT SHALL BE NEW AND SHALL BEAR THE LISTING LABEL OF A NATIONALLY RECOGNIZED TESTING LAB AS DEFINED BY OSHA. J.ALL ELECTRICAL DEVICES AND TERMINALS SHALL BE RATED 75°C MINIMUM. K.ALL CONDUCTORS SHALL BE STRANDED COPPER, 600 VOLT RATED. INSULATION TYPE SHALL BE THHN/THWN, FULLY COLOR CODED WITH GAUGE, TYPE AND MANUFACTURER MARKED EVERY 24" ALONG. CONDUCTOR COLOR CODE SHALL BE AS FOLLOWS: L.MINIMUM SIZE WIRE FOR POWER AND LIGHTING CIRCUITS SHALL BE #12 AWG. ALL POWER AND LIGHTING CONDUCTORS SHALL BE ROUTED IN 3/4" CONDUIT MINIMUM. M.EMT OR MC TYPE CABLE IS ALLOWED WHEN CONCEALED IN INTERIOR SPACES. MC TYPE CABLE IS NOT ALLOWED FOR HOMERUNS. N.MAKE ALL CONNECTIONS TO EQUIPMENT PER MANUFACTURER'S REQUIREMENTS. O.ALL EQUIPMENT, SWITCHING DEVICES AND PANELS SHALL BE MOUNTED SO AS TO BE ACCESSIBLE AND SHALL BE MOUNTED PLUMB AND SQUARE WITH WALLS. P.DEVICES AND RACEWAYS PENETRATING FIRE RATED WALLS AND FLOORS SHALL BE SEALED WITH FIRE RESISTIVE MATERIAL, COMPATIBLE WITH CONSTRUCTION PENETRATED, TO MAINTAIN RATING OF THE WALL. SEALANT SYSTEM SHALL BE A U.L. APPROVED SYSTEM AND INSTALLED PER MANUFACTURER'S INSTRUCTIONS. Q.FURNISH AND INSTALL PULL CORD IN ALL EMPTY CONDUITS. R.ALL JUNCTION BOX COVERS WITH POWER WIRING SHALL HAVE THE PANEL AND CIRCUIT LABELED ON THE OUTSIDE SURFACE. ALL LABELS FOR EXPOSED JUNCTION BOXES IN "FINISHED AREAS" SHALL BE LABELED UTILIZING SELF ADHESIVE LABELS PRODUCED BY A MECHANICAL LABELING MACHINE. LABELS FOR JUNCTION BOX COVERS IN CONCEALED LOCATIONS SHALL CONSIST OF THE INFORMATION BEING NEATLY HANDWRITTEN ON THE OUTSIDE SURFACE OF THE COVER WITH A PERMANENT STYLE MARKER. S.CLEARLY LABEL ALL ACCESSIBLE CONDUIT STUBS WITH SYSTEM NAME AND LOCATION (ROOM NUMBER) WHERE THE OTHER END OF THE CONDUIT TERMINATES. USE INDELIBLE INK. THE LABELS SHALL BE LOCATED ON THE CONDUIT IN A POSITION THAT CAN BE EASILY READ. T.ALL 1 POLE BREAKER CIRCUITS SHALL HAVE AN INDEPENDENT NEUTRAL CONDUCTOR. NO EDISON STYLE SHARED NEUTRAL CONDUCTORS ARE ALLOWED. U.ALL CONDUCTORS IN ELECTRICAL PANELS, CABINETS AND EQUIPMENT SHALL BE NEATLY TRAINED AND LACED. V.THE CONTRACTOR SHALL PROVIDE UPDATED CIRCUIT PANEL DIRECTORIES FOR ALL PANELS. DIRECTORIES SHALL BE TYPED. W.PROVIDE ELECTRICAL SUBMITTALS FOR EQUIPMENT SHOWN AS REQUIRED BY DIVISION 1 SPECIFICATIONS. X.ELECTRICAL CONTRACTOR SHALL OBTAIN THE AVAILABLE FAULT CURRENT VALUE FROM THE LOCAL UTILITY OR THE ONE-LINE DIAGRAM AND LABEL THE MAIN BREAKER WITH THAT VALUE. Y.SWITCH AND RECEPTACLE LABELING: IDENTIFY PANELBOARD AND CIRCUIT NUMBER FROM WHICH DEVICES ARE SERVED. USE MACHINE PRINTED LABEL AND 1/8" TEXT. INSTALL ON THE OUTSIDE OF THE FACEPLATE FOR RECEPTACLES AND INSIDE THE FACEPLATE FOR SWITCHES. OCCUPANCY SENSOR WITH MANUAL DIMMING, SET FOR 50% AUTOMATIC ON, AUTOMATIC OFF, WITH MANUAL DIMMING.SOS D DESIGNATES CIRCUIT ON EMERGENCY SOURCE UNMARKED CIRCUIT IS CONCEALED IN CEILING OR WALL. MAINTAIN CONDUIT AND CONDUCTOR SIZE THROUGHOUT ENTIRE CIRCUIT. BEGINNING OF INDIVIDUAL CIRCUIT(S), CIRCUIT NUMBER(S) INDICATED. EDISON STYLE SHARED NEUTRAL CONDUCTORS ARE NOT ALLOWED. EACH 1 POLE BREAKER SHALL BE FURNISHED WITH AN INDIVIDUAL DEDICATED NEUTRAL CONDUCTOR. CONDUIT, STUBBED, CAPPED AND MARKED WITH PULL CORD AS SPECIFIED CONCEALED IN FLOOR OR UNDERGROUND ELECTRICAL GENERAL NOTES A.THESE ELECTRICAL DRAWINGS ARE DIAGRAMMATIC IN NATURE; THEREFORE, THE ELECTRICAL CONTRACTOR SHALL COORDINATE ALL ELECTRICAL EQUIPMENT AND DEVICE LOCATIONS WITH ARCHITECTURAL, MECHANICAL, AND PLUMBING DIVISIONS PRIOR TO ROUGH-IN. REFER TO AND COORDINATE WITH ARCHITECTURAL, MECHANICAL, AND PLUMBING DRAWINGS FOR ADDITIONAL WORK THAT IS REQUIRED BY THE ELECTRICAL CONTRACTOR. B.ALL CONDUIT AND JUNCTION BOXES ARE TO BE CONCEALED UNLESS LOCATED WITHIN DEDICATED ELECTRICAL OR MECHANICAL ROOMS. USE OF SURFACE MOUNTED RACEWAYS IN ALL OTHER SPACES MUST BE APPROVED BY THE ARCHITECT FOR EACH LOCATION. WHERE SURFACE RACEWAYS ARE APPROVED, UTILIZE WIREMOLD, OR APPROVED EQUAL, SURFACE MOUNTED RACEWAYS PAINTED TO MATCH SURROUNDING WALLS. C.REFER TO ARCHITECTURAL ELEVATIONS FOR OUTLET HEIGHTS WHERE THE SPECIFIC OUTLET HEIGHT IS NOT INDICATED. REFER TO THE ELECTRICAL LEGEND FOR THE DEFAULT OUTLET HEIGHT WHEN NOT INDICATED ON ELEVATIONS OR ON AT THE DEVICES. D.PROVIDE PULL-LINE IN ALL EMPTY CONDUITS. E.TERMINATE ALL LOW-VOLTAGE CONDUITS WITH INSULATED THROAT BUSHING. F.MECHANICAL EQUIPMENT INDICATED IS SHOWN IN AN APPROXIMATE LOCATION. COORDINATE EXACT LOCATION WITH MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN. USB DUPLEX CONVENIENCE OUTLET, +18" AFF UNO USB FOURPLEX CONVENIENCE OUTLET, +18" AFF UNO SHEET TITLE: CHECKED BY: JOB NUMBER: REVISION DATE RE X B U R G , I D PR O J E C T : CONTRACTOR SHALL VERIFY ALL DIMENSIONS & CONDITIONS SHOWN OR IMPLIED M y e r s 92 7 M a i n S t r e e t , S u i t e 3 0 0 ■ E v a n s t o n , W y o m i n g 8 2 9 3 0 ■ T e l . ( 3 0 7 ) 7 8 9 - 0 9 3 4 12 2 S o u t h M a i n S t r e e t ■ P o c a t e l l o , I d a h o 8 3 2 0 4 ■ T e l . ( 2 0 8 ) 2 3 2 - 3 7 4 1 ■ F a x ( 2 0 8 ) 2 3 2 - 3 7 8 2 AI A N C A R B A S I D DRAWN BY: PROJECT DATE: SHEET MR I Z O N E S DRAWING SCALE APPLIES TO 22" X 34" SHEET SIZE ■ Ar c h i t e c t u r e A n d e r s o n ■ I n t e r i o r D e s i g n ■ Hi s t o r i c P r e s e r v a t i o n MA D I S O N M E M O R I A L HO S P I T A L PROJECT NO.21-468 ELECTRICAL COVER SHEET E000 10/27/2021 All wiring must meet 2017 NEC requirements GSPublisherVersion 1169.55.55.100 E100 E101 B. LEDFORD SHEET TITLE: JOBNUMBER: REVISION DATE RE X B U R G , ID PR O J E C T : CONTRACTOR SHALL VERIFY ALL DIMENSIONS & CONDITIONS SHOWN OR IMPLIED 21553-21B OCTOBER 2021 M y e r s 92 7 Ma i n St r e e t , Su i t e 30 0 ■ Ev a n s t o n , Wy o m i n g 82 9 3 0 ■ Te l . (30 7 ) 78 9 - 09 3 4 12 2 So u t h Ma i n St r e e t ■ Po c a t e l l o , Id a h o 83 2 0 4 ■ Te l . (20 8 ) 23 2 - 37 4 1 ■ Fa x (20 8 ) 23 2 - 37 8 2 AI A NC A R B AS I D DRAWNBY: PROJECTDATE: SHEET MR I ZO N E S DRAWING SCALE APPLIES TO22" X 34" SHEET SIZE ■ Ar c h i t e c t u r e A n d e r s o n ■ In t e r i o r De s i g n ■ Hi s t o r i c Pr e s e r v a t i o n MA D I S O N ME M O R I A L HO S P I T A L 1 J (E) CR1 CR J J J J J J 3 3 3 3 2 4 4 4 4 STUB UP 4"ABOVE CEILING ON OPPOSITE SIDE OF DOOR ACCESSIBLE CEILING FINISHED FLOOR SINGLE GANG DEVICE COVER RANDL D-51GO12 OR EQUAL WALL STUD ANTI-SHORT PLASTIC BUSHING ARLINGTON INDUSTRIES EMT75 OR EQUAL ON OPPOSITE SIDE OF DOOR VA R I E S FLOOR PLATE TOP PLATE ELECTRICAL CONTRACTOR RESPONSIBLE FOR INSTALLATION OF CARD READER ROUGH-IN TYPICAL DETAIL - ACTUAL INSTALLATION MAY VARY MAGNETIC DOOR LOCK SEE ARCHITECTURAL DOOR SCHEDULE STUB 3/4"C INTO DOOR FRAME ON OPPOSITE SIDE OF DOOR 3/4"C EMT WITH PULLSTRING ON OPPOSITE SIDE OF DOOR MAGNETIC DOOR LOCK ON OPPOSITE SIDE OF DOOR SEE ARCHITECTURAL DOOR SCHEDULE DOOR EXIT DEVICE ON OPPOSITE SIDE OF DOOR SEE ARCHITECTURAL DOOR SCHEDULE STUB UP 4"ABOVE CEILING WALL STUD ANTI-SHORT PLASTIC BUSHING ARLINGTON INDUSTRIES EMT75 OR EQUAL STUB 3/4"C INTO DOOR FRAME 3/4"C EMT WITH PULLSTRING SINGLE GANG DEVICE COVER RANDL D-51GO12 OR EQUAL FINISHED FLOOR 4-11/16" SQUARE JUNCTION BOX WITH SINGLE GANG MUDRING RANDL TB55057 OR EQUAL FOR ADA OPERATOR 4-11/16" SQUARE JUNCTION BOX WITH SINGLE GANG MUDRING RANDL TB55057 OR EQUAL FOR ACCESS CONTROL 4-11/16" SQUARE JUNCTION BOX WITH SINGLE GANG MUDRING RANDL TB55057 OR EQUAL FOR ADA OPERATOR ADA DOOR OPERATOR SEE ARCHITECTURAL DOOR SCHEDULE ACCESSIBLE CEILING FINISHED FLOOR WALL STUD VA R I E S FLOOR PLATE TOP PLATE CARD READER ROUGH-IN ELEVATION ELECTRICAL CONTRACTOR RESPONSIBLE FOR INSTALLATION OF CARD READER ROUGH-IN TYPICAL DETAIL - ACTUAL INSTALLATION MAY VARY MAGNETIC DOOR LOCK SEE ARCHITECTURAL DOOR SCHEDULE MAGNETIC DOOR LOCK ON OPPOSITE SIDE OF DOOR SEE ARCHITECTURAL DOOR SCHEDULE DOOR EXIT DEVICE ON SEE ARCHITECTURAL DOOR SCHEDULE STUB UP 4"ABOVE CEILING WALL STUD ANTI-SHORT PLASTIC BUSHING ARLINGTON INDUSTRIES EMT75 OR EQUAL STUB 3/4"C INTO DOOR FRAME 3/4"C EMT WITH PULLSTRING SINGLE GANG DEVICE COVER RANDL D-51GO12 OR EQUAL FINISHED FLOOR 4-11/16" SQUARE JUNCTION BOX WITH SINGLE GANG MUDRING RANDL TB55057 OR EQUAL FOR ADA OPERATOR ADA DOOR OPERATOR SEE ARCHITECTURAL DOOR SCHEDULE 4-11/16" SQUARE JUNCTION BOX WITH SINGLE GANG MUDRING RANDL TB55057 OR EQUAL FOR ADA OPERATOR. ON OPPOSITE SIDE OF DOOR 3/4"C EMT WITH PULLSTRING ON OPPOSITE SIDE OF DOOR SHEET TITLE: CHECKED BY: JOB NUMBER: REVISION DATE RE X B U R G , I D PR O J E C T : CONTRACTOR SHALL VERIFY ALL DIMENSIONS & CONDITIONS SHOWN OR IMPLIED M y e r s 92 7 M a i n S t r e e t , S u i t e 3 0 0 ■ E v a n s t o n , W y o m i n g 8 2 9 3 0 ■ T e l . ( 3 0 7 ) 7 8 9 - 0 9 3 4 12 2 S o u t h M a i n S t r e e t ■ P o c a t e l l o , I d a h o 8 3 2 0 4 ■ T e l . ( 2 0 8 ) 2 3 2 - 3 7 4 1 ■ F a x ( 2 0 8 ) 2 3 2 - 3 7 8 2 AI A N C A R B A S I D DRAWN BY: PROJECT DATE: SHEET MR I Z O N E S DRAWING SCALE APPLIES TO 22" X 34" SHEET SIZE ■ Ar c h i t e c t u r e A n d e r s o n ■ I n t e r i o r D e s i g n ■ Hi s t o r i c P r e s e r v a t i o n MA D I S O N M E M O R I A L HO S P I T A L PROJECT NO.21-468 POWER PLAN E100 POWER PLAN 1/8" = 1'-0" SYMBOL USED FOR NOTE CALLOUT. KEYED NOTES: 1.SEE CARD READER ROUGH-IN ELEVATION DETAIL THIS PAGE. CONNECT TO EXISTING POWER CIRCUIT IN ROOM. 2.EXISTING JUNCTION BOX FOR RECEPTACLES. EXTEND 120VOLT POWER TO NEW DOOR OPERATORS. 3.JUNCTION BOX ADJACENT TO ACCESS CONTROL JUNCTION BOX FOR ADA OPERATOR CONNECTING CONDUCTORS. 4.CONNECT POWER TO NEW ELECTRIC DOOR OPERATORS. SEE ARCHITECTURAL SCHEDULE FOR ACTUATOR MODEL NUMBER # NORTH DOOR ACCESS CONTROL AND ADA OPERTOR ROUGH-IN NOT TO SCALE SOUTH DOOR ACCESS CONTROL AND ADA OPERTOR ROUGH-IN NOT TO SCALE 10/27/2021