Loading...
HomeMy WebLinkAboutAPPROVED PLANS - 20-00886 - 859 Pine Brook Ln - Faires New SFRAuthor Name Author Email Author Phone No.: Larry Beesley Larry.Beesley@rexburg.org 208-372-2176 Alan Parkinson Alan.Parkinson@rexburg.org 208-372-2165 Description : 859 Pine Brook Ln - Faires New SFR Address : Record Type : New Single Family Residence Document Filename : Faires Permit Set 060220.pdf Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Approved # 20-00886 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments A1 Free text Larry Beesley : Building Open 1 Street Number Displayed on House A1 Free text Larry Beesley : Building Open 1 Roof Ventilation as per R806 A1 Free text Larry Beesley : Building Open 1 Minimum Frost Depth Ground Surface to Bottom of Footing 36" A1 Free text Larry Beesley : Building Open 1 Ground Surface to Slope away from Foundation a minimum of 6" within first 10 ft. A2 Free text Larry Beesley : Building Open 2 20 minute fire door A2 Free text Larry Beesley : Building Open 2 Build garage according to the engineering provided. A2 Free text Larry Beesley : Building Open 2 Radon Reduction System IRC Appendix F A2 Free text Larry Beesley : Building Open 2 Rebar: 8' Wall-Horizontal & Vertical 24" O.C. with 2 in Top 12" Rebar: 4' Wall-Horizontal & Vertical 24" O.C. with 1 in Top 6" A3 Free text Larry Beesley : Building Open 3 SD CO A3 Free text Larry Beesley : Building Open 3 block wall for nailing the edges of the sheeting on the outside A3 Free text Larry Beesley : Building Open 3 The garage area is engineered. New Single Family Residence Make sure to follow the engineering specks for the garage. Approval of plans does not constitute approval of variance from code Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments A4 Free text Larry Beesley : Building Open 4 Roof Trusses (designed according to R802.10.1) 35 # Snow and 90 mph winds (Local Conditions) A4 Free text Larry Beesley : Building Open 4 Rebar: 8' Wall-Horizontal & Vertical 24" O.C. with 2 in Top 12" Rebar: 4' Wall-Horizontal & Vertical 24" O.C. with 1 in Top 6" A5 Free text Alan Parkinson : P&Z Open 5 Sidewalk and landscape strip shall be installed per City of Rexburg Engineering Standards - Street Section RR2. A5 Free text Alan Parkinson : P&Z Open 5 Plans are approved for the principal building. All other ancillary buildings will need to go through the permitting process. Approval of plans does not constitute approval of variance from code Powered by TCPDF (www.tcpdf.org) Elevations Scale: 1/4" & 1/8" =1'-0" on 36" x 24" Paper 7:12 Pitch Main, Front and Sides Scale: 1/8" & 1/16"=1'-0" on 17" x 11" Paper A1 Su n d a n c e dr a f t i n g & d e s i g n PAGE LAYOUT A1-Elevations A2-Foundation/Basement Plan A3-Floor Plan A4-Cross Section A5-Plot Plan Sundance Drafting and Design tries to provide the most accurate information for your house design as possible, if design information is not provided correctly Sundance is not liable. Many factors occur in construction during the building process that change the continuity of this drawing. Due to these factors if the plan is not followed or changes occur after the final print has been given, Sundance Drafting and Design is not liable for those items. Read through all pages provided. Review all the notations and labels on each page. Engineering supersedes all drafting notations. Labeling by County or City Inspectors have to be followed. Footing, Foundation, Rebar, and Shear walls are specified and have to be followed. Floor Layouts and Truss Details are separate from these pages but need to be kept together and followed. If any problems with the plans, please notify Sundance Drafting and Design. The undersigned has looked through these pages and agrees that all discussed between Client/Contractor and Sundance Drafting and Design is noted and correct Please Initial Here These Plans follow the 2015 IRC Codes Permitting and Inspections Section 106,107,108, & 109 1. For a permit you will need 2 sets of the following: House plans, Floor Layout, Truss Details, Rescheck, Heat Loss Analysis, and Engineer Stamp (if needed). 2. Review entire set of plans including the above described with owner/contractor. 3. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. Sundance Drafting and Design is not liable for construction mistakes. 4. This drawing is not to be duplicated without written or verbal consent by Tiffany Stoddart. GENERAL NOTES: 1/4"=1'-0" UNO Co p y r i g h t S u n d a n c e D r a f t i n g & D e s i g n 2 0 2 0 Copyright Sundance Drafting and Design 2020 Copyright Sundance Drafting and Design 2020 1/8"=1'-0" UNO Start Date Permit Set Bid Set 9' Main Walls 9' Basement Foundation Walls Garage to Match Main TYP TOTAL SQ. FTG.= 4405 MAIN FLOOR=2237/2130 INTERIOR BASEMENT=2180/1962 INTERIOR GARAGE=1038 20 8 . 5 2 4 . 2 8 8 0 N EE D AH OU S E P LA N . C O M Rev Rev A5 of Stucco Right Elevation Rev Fa i r e s R e s i d e n c e Front Elevation Left Elevation Back Elevation 11-18-2019 12 7 12 7 3' 4' - 6 " 12 7 12 7 Vinyl Siding Faux Stone 12-17-2019 2' 8" 9' 1' - 2 " 9' Asphalt Shingles 12 4 12 4 4:12 Pitch Break 4:12 Pitch Break 06-02-2020 PE R M I T S E T Street Number Displayed on House Roof Ventilation as per R806 Minimum Frost Depth Ground Surface to Bottom of Footing 36" Ground Surface to Slope away from Foundation a minimum of 6" within first 10 ft. Foundation Plan Scale: 1/4"=1'-0" 36"x24" Size Paper Scale: 1/8"=1'-0" 17"x11" Size Paper A2A2 Su n d a n c e dr a f t i n g & d e s i g n PAGE LAYOUT A1-Elevations A2-Foundation/Basement Plan A3-Floor Plan A4-Cross Section A5-Plot Plan Sundance Drafting and Design tries to provide the most accurate information for your house design as possible, if design information is not provided correctly Sundance is not liable. Many factors occur in construction during the building process that change the continuity of this drawing. Due to these factors if the plan is not followed or changes occur after the final print has been given, Sundance Drafting and Design is not liable for those items. Read through all pages provided. Review all the notations and labels on each page. Engineering supersedes all drafting notations. Labeling by County or City Inspectors have to be followed. Footing, Foundation, Rebar, and Shear walls are specified and have to be followed. Floor Layouts and Truss Details are separate from these pages but need to be kept together and followed. If any problems with the plans, please notify Sundance Drafting and Design. The undersigned has looked through these pages and agrees that all discussed between Client/Contractor and Sundance Drafting and Design is noted and correct Please Initial Here These Plans follow the 2015 IRC Codes Permitting and Inspections Section 106,107,108, & 109 1. For a permit you will need 2 sets of the following: House plans, Floor Layout, Truss Details, Rescheck, Heat Loss Analysis, and Engineer Stamp (if needed). 2. Review entire set of plans including the above described with owner/contractor. 3. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. Sundance Drafting and Design is not liable for construction mistakes. 4. This drawing is not to be duplicated without written or verbal consent by Tiffany Stoddart. GENERAL NOTES: 1/4"=1'-0" UNO Co p y r i g h t S u n d a n c e D r a f t i n g & D e s i g n 2 0 2 0 Copyright Sundance Drafting and Design 2020 Copyright Sundance Drafting and Design 2020 1/8"=1'-0" UNO Start Date Permit Set Bid Set TOTAL SQ. FTG.= 4405 MAIN FLOOR=2237/2130 INTERIOR BASEMENT=2180/1962 INTERIOR GARAGE=1038 20 8 . 5 2 4 . 2 8 8 0 N EE D AH OU S E P LA N . C O M Rev Rev A5 of Rev Fa i r e s R e s i d e n c e 22" LAP (Typ) 22 " L A P (T Y P ) #4 @ 2'-0" O.C. E. W. 23/32 APA Rated Sheathing W/ Tar Paper Between Sheathing and Concrete Tar Paper 2x Pressure Treated Rim (Match Floor Joist Depth) #4 @ 2'-0" O.C. 24 2x4 Pressure Treated Sill Plate W/1/2" Dia. Anchor Bolts @ 4'-0" O.C. Wall Framing (By Others) Floor Framing (By Others) 1 1/4" (Min.) Eng Rim Joist Foundation Wall (By Others) Floor Joist (See Table) 2x Ledger W/Simpson 1/4" SDS Screws (Match Floor Joist Depth) (See Table) Simpson LUS Joist Hanger W/ SD Screws @ Each Joist Span (See Table) Slope Cold Storage Detail Scale: 1/4"=1'-0" UNO D Size Paper Scale: 1/8"=1'-0" UNO B Size Paper Span (See table) Le n g t h ( A s p e r A r c h D r a w i n g s 3' - 0 " Ma x . GENERAL STRUCTURAL NOTES A. CODES AND SPECIFICATIONS 1.International Building Code (IRC) - 2012 Edition 2.ACI 318-11 Building Code Requirements for Reinforced Concrete 3.ANSI/AF&PA National Design Specifications (NDS) & Suppl. for Wood Const. -2012 Edition 4.ASCE 7-10 Min. Design Loads for Buildings and other Structures B. DESIGN LOADS UNIFORM (PSF) 1.Floor Loads Uniform a. Deck Live = 100 C. MATERIALS 1. Dimensional Lumber #2 Douglas Fir 2. Concrete fc Slab 4000 PSi 3. Reinforcing Steel ASTM A615 - Grade 60 4. Anchor Bolts A36/F1554 GRADE 36 4" Concrete Deck Table Span Joist Size Joist Spacing SDS 1/4 x 3 1/2 Screw Spacing 4'-0"2x4 16" O.C.8" O.C. 6'-0"2x6 16" O.C.5" O.C. 8'-0"2x8 16" O.C.4" O.C. 6" Concrete Deck Table Span Joist Size Joist Spacing SDS 1/4 x 3 1/2 Screw Spacing 4'-0"2x4 16" O.C.7" O.C. 6'-0"2x6 16" O.C.4 1/2" O.C. 8'-0"2x8 12" O.C.3" O.C. 11-18-2019 5' 30 6 8 4040 SV 4040 SV 3068 2668 Bedroom 6 14'-8" x 11'-0" 10 CFM Fresh Air Smoke Detector Bath 50 CFM Family Room 18'-10" x 15'-10" 10 CFM Fresh Air Mechanical Cold Storage 3' Clearance in front of Furnace Seismic Straps around WH Kitchenette 100 CFM 3' - 4 " 23'-8" 20 ' - 1 0 " D o w n 8' - 5 " 3' - 2 " 3'-6" Future Elevator 5' Use as CL now 5' 30 6 8 Bedroom 5 10'-0" x 13'-6" 10 CFM Fresh Air Smoke Detector Bedroom 4 11'-8" x 10'-0" 10 CFM Fresh Air Smoke Detector Office 10'-10" x 11'-8" 10 CFM Fresh Air Smoke Detector 17 ' - 4 " 12'-8" 3068 2' 4040 SV 6' - 3 " 5050 SV 4040 SV 4040 SV 4040 SV 4' - 1 0 " Theater Room 6' - 3 " Entry 5050 SV 8' 7' 14'-8"5'13' 24'-8" 4' 34'28' 37 ' 2' 6' 13'32'-8"12'-6"28'-6" 39 ' 7' 2-2468 5050 SV 30 6 8 4' DW 10'-6" 4' 7' - 6 " 15 ' - 5 " 5'-11" 4' - 3 " 11'-5" 3068 7' 22 ' - 2 " 7' - 1 0 " 3068 2'-6"2'-6" Cut 3' for Passage Opening with Req. Blocking 3' Cut 3' for Passage Opening with Req. Blocking 4' - 9 " 27 ' - 3 " UP 7'-6"6'15'-6"5' 4' 4' Cut 10' for Garage Door opening with Req. Blocking Cut 18' for Garage Door opening with Req. Blocking Cut 3' for Passage Opening with Req. Blocking Cut 3' for Passage Opening with Req. Blocking 7'-8"20'-4" 12 ' 18 ' 9'3' - 1 0 " 3' - 2 " 9' Basement F. Walls2- 2 0 6 8 2- 2 0 6 8 26 6 8 2-2468 hood Utility 50 CFM Wo o d B u r n i n g 2' 21'-10"2'-10" Be a m Be a m Floor Joist Direction Floor Joist Direction Floor Joist Direction Floor Joist Direction 24 ' - 5 " 4' - 4 " 13'-7"11'-1" 4' 7'-11"5' 2668 5' 5'-4" add 110 Plug 3068 Bath 50 CFM 4' 2x 6 W a l l 2-2468 3068 47 ' 86'-8" 8' 86'-8" 2x 6 W a l l 12-17-2019 26 6 8 Grab Bar Cl o s e t Curbless Shower Fold up seat 2' - 4 " 26 6 8 Linen 9' Main Walls 9' Basement Foundation Walls Garage to Match Main TYP S CM HOLDDOWN: H1 SIMPSON STRONG TIE STHD14-INSTALLED & NAILED AS PER MANUFACTURERS RECOMMENDATIONS CONCRETE TO WOOD CONNECTION Ce n t e r O f Fo o t i n g H1 H1 H1 Bath 50 CFM Header Notes: Headers 4' or less use 1 Ply 9.50 or 2 Ply 2x10 Dim. Lumber Headers 6' or less use 2 Ply 9.50 Headers 8' or less use 3 Ply 9.50 or 2 Ply 11.88 ML Headers 10' or less use 3 Ply 11.88 or 2 Ply 14.00 ML Headers 10' or more refer to TJXpert Layout Exhaust and Ventilation: Whole House Fan 80 CFM Kitchen Fan 100 CFM Laundry 50 CFM Bathrooms 50 CFM Bedrooms 10 CFM fresh air Living Areas 10 CFM fresh air Contractor to indicate location of fans if not indicated on plans already. Window Callouts: Width then Height (ex. 3050 is 3'0" wide by 5'0" Tall) Door same SH-is Single Hung DH is Double Hung SV is Side Vent Fix is Fixed or Picture T or Temp is Tempered Safety Glass Tra is Transom Ventilation R408.1 The under-floor space between the bottom of the floor joists and the earth under any building (except space occupied by a basement) shall have ventilation openings through foundation walls or exterior walls. The minimum net area of ventilation opening shall not be less than 1 s/f for each 150 s/f of under floor space area, unless the ground surface is covered by a Class 1 vapor retarder material. If the vapor retarder is used the min. net area of ventilation openings shall not be less than 1 s/f for each 1500 s/f. One such vent shall be within 3' of each corner of building. GFoundation Wall System: 2x6 Treated Sill Plate over Foam Sill Sealer with 1 2" Anchor Bolts @ 72" O.C. 10" Long, 7" Embedded Max. 12" from all Corners or Splices Concrete Wall Greater than 9' need to have an Architects or Engineer Seal 8' & under (1) Horiz. Bar in top 12" and one at mid-height 8'-1" to 9' (1) Horiz. Bar in top 12" & one bar at each third point Min. (2) Anchor Bolts per Sill Plate w/ nut & ROUND plate Washer 2 1/2 Ø x1 4" Min. For each Bolt over Concrete Foundation wall Consistent w/ 2015 IRC R401-403 With Asphalt Emulsion on Exterior Side over Continuous Concrete Footings Consistent w/ 2015 IRC Section R106.1 over Undisturbed Soil Window Well System: 2015 IRC Code Min. egress window opening will be 5.7 sq. ft 7 Sill height no higher than 44" above FFL Window wells provide a net clear of 9 sq. ft. w/min horiz. projection & width of 36" Exception: Window Wells w/depth greater than 44" will have a permanently affixed ladder or steps. Ladder or Steps 12"-width Inside, 3"-from walls, Spaced no more than 18" O.C. One egress ladder shall be provided within a window well of an unfinished basement J Smoke Alarms 2015 IRC Code Section 106. R314 All smoke alarms shall be listed in accordance with UL 217 & installed in accordance with NFPA 72 -One in each sleeping area -Outside of each separate sleeping area in the immediate vicinity of the bedrooms -On each additional story including un-finish & finished basements and habitable attics but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with splits levels and without an intervening door between the adjacent levels a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. -Alarm devices shall be interconnected with battery backup that the actuation of one alarm will activate all of the alarms CM S S S CM TRIPLE CAR GARAGE 4" CONCRETE SLAB SLOPE CONC. FLOOR TO DRAIN TO GARAGE DOOR H1 H1 8' - 1 " H1 11'-1" 12 ' - 4 " 3'-1" 12 ' - 5 " 14'-1" 14'-1" 3' - 6 " 9' - 9 " 2'-6" 2'-4" 13' 23 ' - 1 1 " 12' 5' - 8 " 19'-2" 4' - 8 " 5'-10" 3' - 1 0 " 5'-8"3'-6" 2' - 6 " 10'-3" 5' 6' 5'-11" 3' - 4 " 5'-10"5'-4" 2'-3" 06-02-2020 PE R M I T S E T T-Wall 21 ' - 7 " (See detail to side) 20 minute fire door Build garage according to the engineering provided. Radon Reduction System IRC Appendix F Rebar: 8' Wall-Horizontal & Vertical 24" O.C. with 2 in Top 12" Rebar: 4' Wall-Horizontal & Vertical 24" O.C. with 1 in Top 6" Main Floor Scale: 1/4"=1'-0" 36"x24" Size Paper Scale: 1/8"=1'-0" 17"x11" Size Paper 9' Main Walls 9' Basement Foundation Walls Garage to Match Main TYP A3 Su n d a n c e dr a f t i n g & d e s i g n PAGE LAYOUT A1-Elevations A2-Foundation/Basement Plan A3-Floor Plan A4-Cross Section A5-Plot Plan Sundance Drafting and Design tries to provide the most accurate information for your house design as possible, if design information is not provided correctly Sundance is not liable. Many factors occur in construction during the building process that change the continuity of this drawing. Due to these factors if the plan is not followed or changes occur after the final print has been given, Sundance Drafting and Design is not liable for those items. Read through all pages provided. Review all the notations and labels on each page. Engineering supersedes all drafting notations. Labeling by County or City Inspectors have to be followed. Footing, Foundation, Rebar, and Shear walls are specified and have to be followed. Floor Layouts and Truss Details are separate from these pages but need to be kept together and followed. If any problems with the plans, please notify Sundance Drafting and Design. The undersigned has looked through these pages and agrees that all discussed between Client/Contractor and Sundance Drafting and Design is noted and correct Please Initial Here These Plans follow the 2015 IRC Codes Permitting and Inspections Section 106,107,108, & 109 1. For a permit you will need 2 sets of the following: House plans, Floor Layout, Truss Details, Rescheck, Heat Loss Analysis, and Engineer Stamp (if needed). 2. Review entire set of plans including the above described with owner/contractor. 3. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. Sundance Drafting and Design is not liable for construction mistakes. 4. This drawing is not to be duplicated without written or verbal consent by Tiffany Stoddart. GENERAL NOTES: 1/4"=1'-0" UNO Co p y r i g h t S u n d a n c e D r a f t i n g & D e s i g n 2 0 2 0 Copyright Sundance Drafting and Design 2020 Copyright Sundance Drafting and Design 2020 1/8"=1'-0" UNO Start Date Permit Set Bid Set TOTAL SQ. FTG.= 4405 MAIN FLOOR=2237/2130 INTERIOR BASEMENT=2180/1962 INTERIOR GARAGE=1038 20 8 . 5 2 4 . 2 8 8 0 N EE D AH OU S E P LA N . C O M Rev Rev A5 of Rev Fa i r e s R e s i d e n c e 11-18-2019 3068 3' 3'-6" 3' 37 ' 34' 22'-6" 5'-4" 24'-8" 6' 39 ' 7' - 2 " 3'4'-6"3'-6" 7'-6" 10 ' - 6 " 3'-4" 2x 6 W a l l 9'-6"4' - 1 0 " 5'-6" 23'-8" 10 ' - 1 0 " Drain 3'-6"2'-6" 3068 Lockers 30 6 8 Front Porch 30 6 8 Hidden Pantry 10 ' - 6 " 30 6 8 With doggie door With doggie door 5' - 4 " 3' - 6 " Bu i l t - i n s Bu i l t - i n s DW 18x9 OH Garage Door 10x9 OH Garage Door D o w n 4' 10 ' 4' 18 ' 3' 2'2' 7' 14'-8"13'12'-6"28'-6" 8' 7' 1' 86'-8" 39 ' 30 6 8 Master Bedroom/1 15'-0" x 14'-6" 10 CFM Fresh Air 9' Flat Ceiling Smoke Detector Master Bath 50 CFM WIC Bath 50 CFM Bedroom 3 12'-8" x 11'-4" 10 CFM Fresh Air 9' Flat Ceiling Smoke Detector Bedroom 2 11'-2" x 11'-0" 10 CFM Fresh Air 9' Flat Ceiling Smoke Detector Great Room 20'-0" x 20'-8" 10 CFM Fresh Air 9' Flat Ceiling Dining 13'-0" x 10'-0" 10 CFM Fresh Air 9' Flat Ceiling Kitchen 13'-0" x 10'-8" 100 CFM 9' Flat Ceiling Utility 10'-0"x7'-6" 50 CFM 80 WHF Entry 9' Ceiling Office 9' Ceiling 12'-0"x10'x0" Mud Room 3 Car Garage 1038 Square Feet 2- 2 6 6 8 2668 3068 Future Elevator 3'-6" 2 6 6 8 4' 13' 2' 4'-10" 3068 5' 3068 30 6 8 Use as CL now 6' 7' 4' 2- 2 6 6 8 10 11 12 13 14 1' - 3 " Ra i s e 4' 3'- 1 0 " 2' Li n e n 2468 Down Bu i l t - i n s Drain 2 6 6 8 2' - 4 " 2668 P. 40 1 0 S V 40 1 0 S V 3010 SV 3050 SH 6046 F. 3046 SH 5040 F.6068 Slider 2' ShelvesShoe 2'-6" 5040 SV 5040 SV 5030 SV 4040 SV 4040 SV Bottom of Window 3' off the floor so HH Shelf 40" off ground 2'-2" 3' 50 1 0 S V 2010 F ØC G A S F P 2'Chimney Stack Duct Chase Train ledge 12" from ceiling Windows 4' off ground Co n s u l t o w n e r 3046 SH 5'-4" 86'-8" 13'32'-8"41' 2010 F 12-17-2019 3' - 1 0 " 7'-6" Trash and Recycle cupboard 2'4068 P Electrical and Water hookup for Future Sauna Garage Portals: Alternate Braced Wall Panel Garage Portal Design PFH See Figure R602.10.6.2 Sheet A4 Contractor to locate exact location of req'd 22" x 30" Attic Access Point Min. 30" Vert. Head Room Clearance (2009-R807.1) 20min Fire Rated 1-3/8" Solid Door or Equal, Self Close9'-10" 1'-9 " 3050 SH 1'-2" 22'-2" 4'-4"5'-6"14'-10" 39'-6" 5'-6" 2'-6"3'2'-6"10'2'-4"5'-3"5'5'6'-9"7'-9"4'-3"1'-10"20'-8" 4' 12 ' - 2 " 6' 5' - 8 " 6' - 6 " 6' - 8 " 6' - 2 " 6' 3' 3' 3' - 3 " 3' - 3 " 7'-8"5'-4"7'-4"7'-4"2'-6"2'-6"6'-6"6'-6"8'-9"11'8'-9" 3' - 2 " 3'-4"4"4'10'-8"5'-4"11'-4 1/2"4'-3 1/2"11'-10"3' - 1 0 " 3' - 4 " 13'-8"20' 3' 2'-6" Hook and Latch 3' - 6 " 3' - 1 0 " 3' 3' - 1 0 " 8' - 1 1 / 2 " 1 ' - 7 " 8' - 6 " 4' - 9 " 5 ' - 8 1 / 2 " 1 ' - 1 0 "15 7' - 1 0 " 4' - 4 " 3' - 4 " PF H PF H PF H Header Notes: Headers 4' or less use 1 Ply 9.50 or 2 Ply 2x10 Dim. Lumber Headers 6' or less use 2 Ply 9.50 Headers 8' or less use 3 Ply 9.50 or 2 Ply 11.88 ML Headers 10' or less use 3 Ply 11.88 or 2 Ply 14.00 ML Headers 10' or more refer to TJXpert Layout 3' Hallway Clearance 2015 IRC, Section R106 and R311.6 Saftey Glazing 2015 IRC, Sections R106 and R308.4.5 Exhaust and Ventilation: Whole House Fan 80 CFM Kitchen Fan 100 CFM Laundry 50 CFM Bathrooms 50 CFM Bedrooms 10 CFM fresh air Living Areas 10 CFM fresh air Contractor to indicate location of fans if not indicated on plans already. Window Callouts: Width x Height (ex. 3050 is 3'0" wide by 5'0" Tall) Door same SH-is Single Hung DH is Double Hung SV is Side Vent F is Fixed or Picture T or Temp is Tempered Safety Glass Tra is Transom OBS Obscured Smoke Alarms 2015 IRC Code Section 106. R314 All smoke alarms shall be listed in accordance with UL 217 & installed in accordance with NFPA 72 -One in each sleeping area -Outside of each separate sleeping area in the immediate vicinity of the bedrooms -On each additional story including un-finish & finished basements and habitable attics but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with splits levels and without an intervening door between the adjacent levels a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. -Alarm devices shall be interconnected with battery backup that the actuation of one alarm will activate all of the alarms S Crawl Space: Through Floor min 18"x24" or through perimeter wall min 16"x24" required crawl space opening. If applicable, refer to mechanical code for access requirements where mechanical equipment is located under floors. 2015 IRC, Section R106, R408.4 M1305.1.4 Carbon Monoxide Alarms 2015 IRC Section 106 & R315.1 New Construction an approved carbon monoxide alarm installed outside of each sleeping area in the immediate vicinity of bedroom and dwelling units. They shall be listed as complying with UL 2034 and installed accordingly CM Furnace: Location of furnace and water heater 2015 IRC, Section R106, and M1305 Elevate all sources of ignition in the garage a min. of 18" above the floor 2015 IRC, Sections R106, and M1307.3 Provide a protection post in the garage to prevent vehicle damage to furnace and water heater. 2015 IRC, Section R106, M1307.3.1 PFH 3'-10"3'-10" (4 Typ) 1'x1' Post 10 ' - 8 " 5' - 8 " 5' 7'-3" 13' 5'-9" 2x 6 W a l l 1' - 1 0 " 6' - 4 1 / 2 " 4' 9' - 6 " 7' 12 3456789 5'-8"4'-9" 7' - 6 " 8' - 4 " 21 ' - 2 " 15 ' - 4 " 2'-6" 2' - 6 " 8' 7'-11" 06-02-2020 PE R M I T S E T 2'-3" Po n y W a l l 4'-4" 1hr Firewall No Penetrations 50 CFM 2x6 Wall 2x6 Wall 3068 50 CFM 4' 4' 2026 F 12 7 4' 4' 2026 F 12 7 SD CO block wall for nailing the edges of the sheeting on the outside The garage area is engineered. Cross Section Floor System: Interior Walls: Exterior Walls: Soffit System: A C E D B Alternate Reinforcing Bar Size and Spacing Vertical Rebar Only 8" nominal wall thickness 72" Max rebar spacing #4 @ 15" is equal to #5 @ 23" or #6 @ 32" #4 @ 16" is equal to #5 @ 25" or #6 @ 32" #4 @ 16" is equal to #5 @ 25" or #6 @ 36" Load-Bearing Value of Soil (psf) 1500 2000 3000 Conventional Light-frame Construction 1-story 2-story 3-story 4" Brick Veneer over light frame 1-story 2-story 3-story 12 21 32 12 16 24 12 15 23 12 12 17 12 12 16 Table R403.1 Min. Width of Conc. or Masonry Footings (inches) Smoke Alarms 2015 IRC Code Section R314 All smoke alarms shall be listed in accordance with UL 217 & installed in accordance with NFPA 72 -One in each sleeping area -Outside of each separate sleeping area in the immediate vicinity of the bedrooms -On each additional story including un-finish & finished basements and habitable attics but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with splits levels and without an intervening door between the adjacent levels a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. -Alarm devices shall be interconnected with battery backup that the acuation of one alarm will activate all of the alarms S Exhaust and Ventilation: Whole House Fan 80 CFM Kitchen Fan 100 CFM Laundry 50 CFM Bathrooms 50 CFM Bedrooms 10 CFM fresh air Living Areas 10 CFM fresh air Contractor to indicate location of fans if not indicated on plans already. Carbon Monoxide Alarms 2015 IRC Section R315 New Construction an approved carbon monoxide alarm installed outside of each sleeping area in the immediate vicinity of bedroom and dwelling units. They shall be listed as complying with UL 2034 and installed accordingly Fasteners for Preservative treated wood 2015 IRC Code Section R402.1.1 Fastner for Preservative treated wood shall be of hot dipped zinc-coated galvanized steel, stainless steel, silicon bronze or copper. Exceptions: 1. One-half inch (12.7mm) diameter or greater steel bolts. 2. Fasteners other than nail & timber rivets shall be permitted to be of mechanical deposited zinc coated steel with coating weights in accordance with ASTM B695 class 55 min. Frost Protection 403.1.4.1 Except where otherwise protected from frost, foundation walls, piers and other permanent supports of buildings and structures shall be protected from frost by one or more of the following methods: 1. Extended below the frost line specified in Table R301.2 2. Construct in accordance with Section 403.3 3. Construct in accordance with ASCE 32 or 4. Erected on Solid Rock Exceptions: -Protection of freestanding accessory structures with an area of 400 of 600 square feet or less, of light frame construction with an eve height of 10' of less shall not be required. -Decks not supported by a dwelling need not be provided with footings that extend below the frost line. -Footings shall not bear on frozen soil unless the frozen condition is permanent. Ventilation 2015 IRC Section R408 The under-floor space between the bottom of the floor joists and the earth under any building (except space occupied by a basement) shall have ventilation openings through foundation walls or exterior walls. The minimum net area of ventilation opening shall not be less than 1 s/f for each 150/f of under floor space area, unless the ground surface is covered by a Class 1 vapor retarder material. If the vapor retarder is used the min. net area of ventilation openings shall not be less than 1 s/f for each 1500 s/f. One such vent shall be within 3' of each corner of building. CM Basement Furring: F 8" Conc. Walls Not Required Not Required #6 at 36" O.C. Not Required Not Required #6 at 35" O.C. #6 at 32" O.C. Not Required #6 at 35" O.C. #6 at 34" O.C. Max. Wall Height 8' 9' 10' Max. Unbalanced Backfill Height 5' or less 6' 7' 5' or less 6' 7' 8' 7' or less 8' 9' 8' and Under (1) Horizontal Rebar in top 12" and one at mid-height 8' and Greater (1) Horizontal Rebar in top 12" and one bar at each third point Min. Vertical Reiforcement Size & Spacing Table R404.1.2 (3) Reinforced Concrete Foundation Walls GM, GC, SM, SM-SC and ML Soils 45 Cross Section Roof System: 2015 IRC Code Section R801, R901 Architectural Grade, 25 year Asphalt Shingles R905 over #15 building felt over 7/16" Ext. OSB roof sheeting w/Clips & nailed 6" O.C.-Edges, 10" O.C.-field over 3:12 and 7:12 Pitch Engineered Trusses @ 24" O.C. (Framed According to Engineered Truss Layout) with R-49 Blown in Attic Insulation with 5/8" Sheet Rock on Interior Side Taped Prep'd for Interior Finishes Contractor to indicate 22"x30" Attic Access Location 2015 IRC Ice Protection Ice Barrier consisting of 2 layers of cemented under-layment and extend from the eave's edge 24" min. from inside exterior wall A E D B 12 21 32 12 16 24 12 12 16 12 12 12 S C Us e t h i s t a b l e u n l e s s a s o i l t e s t i s d o n e A4 Su n d a n c e dr a f t i n g & d e s i g n PAGE LAYOUT A1-Elevations A2-Foundation/Basement Plan A3-Floor Plan A4-Cross Section A5-Plot Plan Sundance Drafting and Design tries to provide the most accurate information for your house design as possible, if design information is not provided correctly Sundance is not liable. Many factors occur in construction during the building process that change the continuity of this drawing. Due to these factors if the plan is not followed or changes occur after the final print has been given, Sundance Drafting and Design is not liable for those items. Read through all pages provided. Review all the notations and labels on each page. Engineering supersedes all drafting notations. Labeling by County or City Inspectors have to be followed. Footing, Foundation, Rebar, and Shear walls are specified and have to be followed. Floor Layouts and Truss Details are separate from these pages but need to be kept together and followed. If any problems with the plans, please notify Sundance Drafting and Design. The undersigned has looked through these pages and agrees that all discussed between Client/Contractor and Sundance Drafting and Design is noted and correct Please Initial Here These Plans follow the 2015 IRC Codes Permitting and Inspections Section 106,107,108, & 109 1. For a permit you will need 2 sets of the following: House plans, Floor Layout, Truss Details, Rescheck, Heat Loss Analysis, and Engineer Stamp (if needed). 2. Review entire set of plans including the above described with owner/contractor. 3. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. Sundance Drafting and Design is not liable for construction mistakes. 4. This drawing is not to be duplicated without written or verbal consent by Tiffany Stoddart. GENERAL NOTES: 1/4"=1'-0" UNO Co p y r i g h t S u n d a n c e D r a f t i n g & D e s i g n 2 0 2 0 Copyright Sundance Drafting and Design 2020 Copyright Sundance Drafting and Design 2020 1/8"=1'-0" UNO Start Date Permit Set Bid Set TOTAL SQ. FTG.= 4405 MAIN FLOOR=2237/2130 INTERIOR BASEMENT=2180/1962 INTERIOR GARAGE=1038 20 8 . 5 2 4 . 2 8 8 0 N EE D AH OU S E P LA N . C O M 4' Nailing or Screws 7" O.C. Max Horiz. & Vert. Blocks at Drywall Joints for 7" O.C. Screws of Nails Drywall is shown cutaway Overlapped Double Plate 2x6 Exterior wall @16"O.C. with 7/16" Waferboard Drywall & Waterboard not Shown for clarity 2x4 Interior Wall @16" O.C. 4'x8' Shear Panel on Both Sides 4' 8'x8' Shear Panel on Single Side 48 . 5 " t o c n t r IBWP 3 Interior Braced Wall Panel IBWP 2015 IRC Section 602.10.1 BWP 3-Interior Braced Wall Method 3 (IRC R602.10) 2x4 Studs @ 16" O.C. w/7/16" OSB Nailed 5" O.C. and 10" Field IBWP 5-Interior Braced Wall Method 5 1/2" min. Gypsum board 48" length applied to both sides OR 96" to one side covering 3 studs spaced 16" or 2 studs spaced 24" apart, blocked Screwed @7"/7" w/1" Drywall Screws All Vert Joints occur over stud All Hori. Joints blocked w/2x4 blocking Braced Wall Panel BWP 3' Braced Walls at each strap with 7/16" OSB one side, blocked in all joints Nailed @ 6"/12" w/ 8d or Stapled @ 4"/8" w 16 ga. All joints must occur over raming member 6" at edge 12" in field 4' 8d @ 12" O.C. in field 8d Nails @ 6" O.C. @ edge Braced Wall Panel Detail BWP IBWP 5 All exterior wall are braced walls. Rev Rev A5 of (1) 5 8" Ø Anchor Bolts R403.1.6 with 2"x2"x316" plate washer Fasten sheathing to header w 8d common or gal. box nails in 3" grid pattern as shown Header to jack-stud strap per table R602.10.6.4 on both sides of opening opposite side of sheathing Min. Length of panel per Table R602.10.5 Min. double 2x4 framing covered w min. 716" thick wood structual panel sheathing w 8d common or gal. box nails at 3" o.c. in framing (studs and sills) as shown. typ. Min. (2) 3500 LB Tie-Down Device (Embedded into Concrete and Nailed into Framing) Typical Portal Frame Construction Double Portal Frame (Two Braced Wall Panels) Height of Braced Wall Panel SDC A,B, and C Windspeed <110 MPH Sheathed Width 2'-8"2'-8" Min. Double 2x4 Post MIN. WIDTHS AND TIE-DOWN FORCES OF ALTERNATE BRACED WALL PANELS Table R602.10.6.1 Tie-Down Force (lb.) 11 ft. 3'-2" 1800 3000 If needed, panel splice edges shall occur over & be nailed to common blocking w/in middle 24" of wall mid-height. One row of 3" o.c. nailing is req. in ea. panel edgeMin. 1000LB Tie down Device Extent of Header 2200 3600 Single Portal Frame (One Braced Wall Panel) Extent of Header 1800 3000 Ma x H e i g h t 1 0 ' - 0 " 1800 3000 - - 1 Seismic Design Category and Windspeed 2'-8" 8 ft. 2'-4" 9 ft. 2'-8" 10 ft. 2'-8" Note a 12 ft. 3'-6" R602.10.6.1, Item 1 R602.10.6.1, Item 2 1800 3000 1800 3000 2000 3300 Sheathed Width SDC D,D, and D Windspeed <110 MPH R602.10.6.1, Item 1 R602.10.6.1, Item 2 1800 3000 0 2 Note a - - Alternate Braced Wall Panel Garage Portal Design Figure R602.10.6.2 Ma x T o t a l W a l l H e i g h t 1 2 ' - 0 " Min. Footing under opening is 12"x12" Min. reinforcing of foundation, (1) #4 bar top & bottom of footing. Lap bars 15" min. 2'-18" finished width for single or double portal Min. 3"x11 14" net header (Steel header prohibited) Scale: 1/4"=1'-0" UNO on 36"x24" Size Paper Scale: 1/8"=1'-0" UNO on 17"x11" Size Paper Rev Portal Frames with Hold Downs (PFH) Fa i r e s R e s i d e n c e 2015 IRC Code R602, R608, R703 Stucco, Faux Stone, and Vinyl Siding over Weather Resistive Barrier 7/16" APA OSB & Nailing Pattern 6"-edge 12"-field 2x6 Stud framed @ 24" O.C. UNO with (2) 2x6 Top Plates with (1) 2x6 Bottom Plate with min. R-21 Batt Insulation with 1/2" Sheetrock Inside Occupancy separation between between house, attic, and garage Taped Prep'd for Interior Finishes 2015 IRC Code 2x6 Fascia Board with style "D" Metal Drip Edge with 3/8" Soffit Sheeting with 3" Continuous Soffit Venting with add'l 2x4 Support as Required 2015 IRC Code 2x4 Stud framed @ 24" O.C. with (2) 2x4 Top Plates with (1) 2x4 Bottom Plate with 1/2" Sheetrock Both Sides Taped Prep'd for Interior Finishes 2015 IRC Code Section R502, R503, R504 3/4" T&G OSB Sub-floor Glued & Nailed over 11-7/8 TJI Engineered Floor Joist Series, Placement, & O.C. Spacing as determined & indicated on TJXpert Layout. (Version 6.0 or later) connected to Rim Joist, spliced using gal. metal ties not less than .058" x 1.5" wide fastened w/6 16d nails ea. side over 1/2" Sheetrock on Ceiling Side Taped and Prep'd for Interior Finishes 2015 IRC Code SectionR602.4 2x4 Stud Framed @ 24" O.C. with Bearing Walls @ 16" O.C. with (2) 2x4 Top Plates with (1) 2x4 Bottom Plate with R-13 Batt Insulation with 6-Mill Poly Vapor Barrier with 1/2" Sheetrock on Interior Side Taped and Prep'd for Interior Finishes Stair System: 2015 IRC R302.7, 311.7.2, R311.7 R312.1.3 Eq. Stair Risers 7 3/4" Max. height, Eq. Stair Treads 10" Min. depth over (3) 11.5" MIN. Stair Stringers bolted at bottom with P.T. 2x4 -3 places with 3" x 1 2" Ø bolt and top securely mounted to framing with Simpson A35 Connector at Stairs Stringer to Ledger or alternate approved connection. with Cont. Handrail System mounted 36"above stair plane. with Handrail return to wall. with a Min. 6'-8" Head Clearance above stair plane. with all other Railing System to be min. 42" above FFL & meet current building codes for vert. and horiz. loading. Slate Spacing to no more than 4" sphere to pass thru. 12" Gypsum Board under stairs 2% Slope Max 1 to 48 H GFoundation Wall System: 2x6 Treated Sill Plate over Foam Sill Sealer with 1 2" Anchor Bolts @ 72" O.C. 10" Long, 7" Embedded Max. 12" from all Corners or Splices Concrete Wall Greater than 9' need to have an Architects or Engineer Seal 8' & under (1) Horiz. Bar in top 12" and one at mid-height 8'-1" to 9' (1) Horiz. Bar in top 12" & one bar at each third point Min. (2) Anchor Bolts per Sill Plate w/ nut & ROUND plate Washer 2 1/2 Ø x1 4" Min. For each Bolt over Concrete Foundation wall Consistent w/ 2015 IRC R401-403 With Asphalt Emulsion on Exterior Side over Continuous Concrete Footings Consistent w/ 2015 IRC Section R106.1 over Undisturbed Soil Window Well System: 2015 IRC Code Min. egress window opening will be 5.7 sq. ft 7 Sill height no higher than 44" above FFL Window wells provide a net clear of 9 sq. ft. w/min horiz. projection & width of 36" Exception: Window Wells w/depth greater than 44" will have a permanently affixed ladder or steps. Ladder or Steps 12"-width Inside, 3"-from walls, Spaced no more than 18" O.C. One egress ladder shall be provided within a window well of an unfinished basement J 11-18-2019 12-17-2019 12 7 12 4 9' 5" 8'-1" to 9' (1) Horiz. Bar in top 12" and one bar at each third point (2) #4 Rebar Horiz. Cont. (2) #4 Rebar Horiz. Cont. (2) #4 Rebar Horiz. Cont. 8" 8' 1' - 2 " 9' 12 ' - 2 1 / 2 " 1' 21 ' - 2 1 / 2 " 22 ' - 4 1 / 2 " 23 ' - 4 1 / 2 " 31 ' - 4 1 / 2 " 32 ' - 0 1 / 2 " AA BB BB BB CC CC EE FG 8' - 9 " 6' - 8 " 3' 35 ° 1 5 ' - 1 1 1 / 2 " H Scale: 1/4"=1'-0" H e a d r o o m H e i g h t H a n d r a i l H e i g h t 10 1/2" 7 3 / 8 " 8" 9' 1' - 2 " Stringer Intermediate Support 16 Steps Porch to Footing Detail Pre s s u r e T r e a t e d 6 x 6 P o s t ( m i n . ) Wood t o C o n c r e t e C o n n e c t o r (2) #4 Rebar Horiz. Cont. B Pre s s u r e T r e a t e d B e a m Siz e b y T J X p e r t L a y o u t Sim p s o n C o l u m n C a p 30 " M i n Pitch D e t e r m i n e d o n A 1 11" Min Run on Conc. Step into house Max Rise 7 3/4" Concrete Steps into House Entry Great Room Hall Family RoomCold Storage 06-02-2020 PE R M I T S E T Roof Trusses (designed according to R802.10.1) 35 # Snow and 90 mph winds (Local Conditions) Rebar: 8' Wall-Horizontal & Vertical 24" O. C. with 2 in Top 12" Rebar: 4' Wall-Horizontal & Vertical 24" O. C. with 1 in Top 6" Plot Plan Scale: 1/16" =1'-0" D Size Paper Scale: 1/32"=1'-0" B Size Paper Pine Brook Estates Div. No. 2, Block No. 6, Lot No.7 Rexburg, Idaho Madison County NORTH A5 Su n d a n c e dr a f t i n g & d e s i g n PAGE LAYOUT A1-Elevations A2-Foundation/Basement Plan A3-Floor Plan A4-Cross Section A5-Plot Plan Sundance Drafting and Design tries to provide the most accurate information for your house design as possible, if design information is not provided correctly Sundance is not liable. Many factors occur in construction during the building process that change the continuity of this drawing. Due to these factors if the plan is not followed or changes occur after the final print has been given, Sundance Drafting and Design is not liable for those items. Read through all pages provided. Review all the notations and labels on each page. Engineering supersedes all drafting notations. Labeling by County or City Inspectors have to be followed. Footing, Foundation, Rebar, and Shear walls are specified and have to be followed. Floor Layouts and Truss Details are separate from these pages but need to be kept together and followed. If any problems with the plans, please notify Sundance Drafting and Design. The undersigned has looked through these pages and agrees that all discussed between Client/Contractor and Sundance Drafting and Design is noted and correct Please Initial Here These Plans follow the 2015 IRC Codes Permitting and Inspections Section 106,107,108, & 109 1. For a permit you will need 2 sets of the following: House plans, Floor Layout, Truss Details, Rescheck, Heat Loss Analysis, and Engineer Stamp (if needed). 2. Review entire set of plans including the above described with owner/contractor. 3. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. Sundance Drafting and Design is not liable for construction mistakes. 4. This drawing is not to be duplicated without written or verbal consent by Tiffany Stoddart. GENERAL NOTES: 1/4"=1'-0" UNO Co p y r i g h t S u n d a n c e D r a f t i n g & D e s i g n 2 0 2 0 Copyright Sundance Drafting and Design 2020 Copyright Sundance Drafting and Design 2020 1/8"=1'-0" UNO Start Date Permit Set Bid Set TOTAL SQ. FTG.= 4405 MAIN FLOOR=2237/2130 INTERIOR BASEMENT=2180/1962 INTERIOR GARAGE=1038 20 8 . 5 2 4 . 2 8 8 0 N EE D AH OU S E P LA N . C O M Rev Rev A5 of Rev Fa i r e s R e s i d e n c e 11-18-2019 12-17-2019 Location of New Construction 85 ' - 2 " 18.47' S 89° 59' 46" W 18 5 . 6 2 ' N 0 ° 0 ' 1 4 " W 13 0 . 7 3 ' N 3 9 ° 5 5 ' 5 0 " E 9 9 . 9 4 ' S 5 7 ° 2 3 ' 4 5 " E C106 R=200.00' L=113.82' 54.21' N 89° 59' 46" E59.41' N 89° 59' 46" E Line of Required Setback Lin e o f R e q u i r e d S e t b a c k Line of Required Setback Li n e o f R e q u i r e d S e t b a c k 98'-7" 9 8 ' - 7 " 5 4 ' - 8 " 10 7 ' - 3 1 / 2 " 45 ' 7' - 6 " 70'-6" 7'-6" 8 2 ' - 5 " 2 5 ' 4 4 ' - 8 1 / 2 " 28 ' - 6 " 39 ' 28 ' 2' 14 ' - 8 " 32 ' 13 '8' 3' 12 ' - 6 " 3 2 ' - 8 " 13 ' 1'7' 34 ' 24 ' - 8 " 37 ' 2' 6' 5' 13 ' 7' 40 ' - 8 " 34'-7 1/2" 53 ' - 8 1 / 2 " 10 ' 42'-1 1/2"26 ' - 9 " 12.90' N 89° 59' 46" E 06-02-2020 PE R M I T S E T Sidewalk and landscape strip shall be installed per City of Rexburg Engineering Standards - Street Section RR2. Plans are approved for the principal building. All other ancillary buildings will need to go through the permitting process.