Loading...
HomeMy WebLinkAboutAPPROVED STRUCTURAL CALCS - 20-00359 - 1149 Larch Dr - Hudson New SFRAuthor Name Author Email Author Phone No.: Larry Beesley Larry.Beesley@rexburg.org 208-372-2176 Description : 1149 Larch Dr - Hudson New SFR Address : Record Type : New Single Family Residence Document Filename : STRUCTURAL CALS - 20-00359.pdf Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Approved # 20-00359 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments Pg 1 Stamp Larry Beesley : Building Open 1 Approved - Building Inspector Pg 1 Free text Larry Beesley : Building Open 1 Follow all of the Engineers specks on this sheet. Pg 1 Rectangle Larry Beesley : Building Open 1 New Single Family Residence The Garage will need to be engineered because of the size and square footage for our seismic zone D. 25' x 35' is the maximum, and not over 900 Sq Ft. Also the back wall has more than 21' feet of windows between brace wall panels. The maximum is 21'. This is found in IRC R602 and table R 602.10.1.3 Approval of plans does not constitute approval of variance from code Powered by TCPDF (www.tcpdf.org) Follow all of the Engineers specks on this sheet.