HomeMy WebLinkAboutAPPROVED PLANS - 21-00332 - 1130 Stone Dr - New SFRAuthor Name Author Email Author Phone No.:
Larry Beesley Larry.Beesley@rexburg.org 208-372-2176
Kyle Baldwin Kyle.Baldwin@rexburg.org 208-372-2164
Description : 1130 Stone Drive - New SFR
Address :
Record Type : New Single Family Residence
Document Filename : PLANS -.pdf
Comment Author Contact Information:
Corrections in the following table need to be applied before a permit can be issued
Review Report
Approved
# 21-00332
Page Reference Annotation
Type
Author : Department Status Page Review Comments Applicant Response Comments
A3.1 Stamp Larry Beesley : Building Open 1 Approved - Building Inspector
A3.1 Free text Larry Beesley : Building Open 1 1/2" Anchor bolts with 3" x 3" x 1/4" square washers (incl.
interior bearing walls) R403.1.6.1
A3.1 Free text Larry Beesley : Building Open 1 x x
A3.1 Free text Larry Beesley : Building Open 1 x x
A3.1 Free text Larry Beesley : Building Open 1 4200 LB HOLD DOWNS
A3.1 Line Larry Beesley : Building Open 1
A3.1 Line Larry Beesley : Building Open 1
A3.1 Free text Larry Beesley : Building Open 1 SD
A3.1 Free text Larry Beesley : Building Open 1 S
A3.1 Free text Larry Beesley : Building Open 1 SD
A3.1 Free text Larry Beesley : Building Open 1 SD CO
A3.1 Free text Larry Beesley : Building Open 1 SD
A3.1 Free text Larry Beesley : Building Open 1 FAN
New Single Family Residence
Approval of plans does not constitute approval of variance from code
Page Reference Annotation
Type
Author : Department Status Page Review Comments Applicant Response Comments
A3.1 Free text Larry Beesley : Building Open 1 Rebar: 8' Wall-Horizontal & Vertical 24" O.C. with 2 in Top 12"
Rebar: 4' Wall-Horizontal & Vertical 24" O.C. with 1 in Top 6"
A3.1 Free text Larry Beesley : Building Open 1 2018 IRC BUILDING CODE
A1.1 Stamp Larry Beesley : Building Open 2 Approved - Building Inspector
A1.1 Free text Larry Beesley : Building Open 2 Street Number
Displayed on House
A1.1 Free text Larry Beesley : Building Open 2 Roof Ventilation as per R806
A1.1 Free text Larry Beesley : Building Open 2 Roof Trusses (designed according to R802.10.1) 35 # Snow and
90 mph winds (Local Conditions)
A1.1 Free text Larry Beesley : Building Open 2 Ground Surface to Slope away from Foundation a minimum of
6" within first 10 ft.
A1.1 Free text Larry Beesley : Building Open 2 Minimum Frost Depth Ground Surface to Bottom of Footing
36"
A6.1 Stamp Larry Beesley : Building Open 3 Approved - Building Inspector
A6.1 Free text Larry Beesley : Building Open 3 Roof Trusses (designed according to R802.10.1) 35 # Snow and
90 mph winds (Local Conditions)
A6.1 Free text Larry Beesley : Building Open 3 Roof Ventilation as per R806
A6.1 Free text Larry Beesley : Building Open 3 Ground Surface to Slope away from Foundation a minimum of
6" within first 10 ft.
A6.1 Free text Larry Beesley : Building Open 3 Minimum Frost Depth Ground Surface to Bottom of Footing
36"
A2.1 Stamp Larry Beesley : Building Open 4 Approved - Building Inspector
A2.1 Free text Larry Beesley : Building Open 4 FAN
A2.1 Free text Larry Beesley : Building Open 4 SD CO
A2.1 Free text Larry Beesley : Building Open 4 SD
A2.1 Free text Larry Beesley : Building Open 4 SD
A2.1 Free text Larry Beesley : Building Open 4 SD
A2.1 Free text Larry Beesley : Building Open 4 SD CO
A2.1 Free text Larry Beesley : Building Open 4 Attic Access 22"x30" minimum access where attic clear height
exceeds 30" (R807)
A2.1 Free text Larry Beesley : Building Open 4 Flue chase shown on plans (B-vents not to be inside insulated
walls without insulation shield)
A2.1 Line Larry Beesley : Building Open 4
A5.1 Stamp Larry Beesley : Building Open 5 Approved - Building Inspector
A5.1 Free text Larry Beesley : Building Open 5 Roof Trusses (designed according to R802.10.1) 35 # Snow and
90 mph winds (Local Conditions)
Approval of plans does not constitute approval of variance from code
Page Reference Annotation
Type
Author : Department Status Page Review Comments Applicant Response Comments
A5.1 Free text Larry Beesley : Building Open 5 Stair Rise/Run (7 3/4' max. rise & 10" min. tread, nosing req'd if
<11")
A5.1 Free text Larry Beesley : Building Open 5 Stairway Headroom (6'8")
A5.1 Free text Larry Beesley : Building Open 5 Footing and foundation sizes ?
A5.1 Free text Larry Beesley : Building Open 5 2018 IRC Code
S1.1 Stamp Larry Beesley : Building Open 6 Approved - Building Inspector
S1.1 Free text Larry Beesley : Building Open 6 Ground Surface to Slope away from Foundation a minimum of
6" within first 10 ft.
S1.1 Stamp Kyle Baldwin : P&Z Open 6 Approved - Planning and Zoning
Approval of plans does not constitute approval of variance from code
1/2" Anchor bolts with 3" x 3" x 1/4" square washers (incl. interior bearing walls) R403.1.6.1
x x x x
4200 LB HOLD DOWNS
SD
S SD
SD CO
SD FAN
Rebar: 8' Wall-Horizontal & Vertical 24" O.C. with 2 in Top 12"
Rebar: 4' Wall-Horizontal & Vertical 24" O.C. with 1 in Top 6"
2018 IRC BUILDING CODE
Street Number
Displayed on House
Roof Ventilation as per R806
Roof Trusses (designed according to R802.10.1) 35 # Snow and 90 mph winds (Local Conditions)
Ground Surface to Slope away from Foundation a minimum of 6" within first 10 ft.
Minimum Frost Depth Ground Surface to Bottom of Footing 36"
Roof Trusses (designed according to R802.10.1) 35 # Snow and 90 mph winds (Local Conditions)
Roof Ventilation as per R806
Ground Surface to Slope away from Foundation a minimum of 6" within first 10 ft.
Minimum Frost Depth Ground Surface to Bottom of Footing 36"
FAN
SD CO
SD
SD
SD
SD CO
Attic Access 22"x30" minimum
access where attic clear height
exceeds 30" (R807)
Flue chase shown on
plans (B-vents not to be
inside insulated walls
without insulation
shield)
Roof Trusses (designed according to R802.10.1) 35 #
Snow and 90 mph winds (Local Conditions)
Stair Rise/Run (7 3/4' max. rise & 10" min. tread, nosing req'd if <11")
Stairway Headroom (6'8")
Footing and foundation sizes ?
2018 IRC Code
Ground Surface to Slope away from
Foundation a minimum of 6" within first
10 ft.