Loading...
HomeMy WebLinkAboutAPPROVED PLANS - 21-00332 - 1130 Stone Dr - New SFRAuthor Name Author Email Author Phone No.: Larry Beesley Larry.Beesley@rexburg.org 208-372-2176 Kyle Baldwin Kyle.Baldwin@rexburg.org 208-372-2164 Description : 1130 Stone Drive - New SFR Address : Record Type : New Single Family Residence Document Filename : PLANS -.pdf Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Approved # 21-00332 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments A3.1 Stamp Larry Beesley : Building Open 1 Approved - Building Inspector A3.1 Free text Larry Beesley : Building Open 1 1/2" Anchor bolts with 3" x 3" x 1/4" square washers (incl. interior bearing walls) R403.1.6.1 A3.1 Free text Larry Beesley : Building Open 1 x x A3.1 Free text Larry Beesley : Building Open 1 x x A3.1 Free text Larry Beesley : Building Open 1 4200 LB HOLD DOWNS A3.1 Line Larry Beesley : Building Open 1 A3.1 Line Larry Beesley : Building Open 1 A3.1 Free text Larry Beesley : Building Open 1 SD A3.1 Free text Larry Beesley : Building Open 1 S A3.1 Free text Larry Beesley : Building Open 1 SD A3.1 Free text Larry Beesley : Building Open 1 SD CO A3.1 Free text Larry Beesley : Building Open 1 SD A3.1 Free text Larry Beesley : Building Open 1 FAN New Single Family Residence Approval of plans does not constitute approval of variance from code Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments A3.1 Free text Larry Beesley : Building Open 1 Rebar: 8' Wall-Horizontal & Vertical 24" O.C. with 2 in Top 12" Rebar: 4' Wall-Horizontal & Vertical 24" O.C. with 1 in Top 6" A3.1 Free text Larry Beesley : Building Open 1 2018 IRC BUILDING CODE A1.1 Stamp Larry Beesley : Building Open 2 Approved - Building Inspector A1.1 Free text Larry Beesley : Building Open 2 Street Number Displayed on House A1.1 Free text Larry Beesley : Building Open 2 Roof Ventilation as per R806 A1.1 Free text Larry Beesley : Building Open 2 Roof Trusses (designed according to R802.10.1) 35 # Snow and 90 mph winds (Local Conditions) A1.1 Free text Larry Beesley : Building Open 2 Ground Surface to Slope away from Foundation a minimum of 6" within first 10 ft. A1.1 Free text Larry Beesley : Building Open 2 Minimum Frost Depth Ground Surface to Bottom of Footing 36" A6.1 Stamp Larry Beesley : Building Open 3 Approved - Building Inspector A6.1 Free text Larry Beesley : Building Open 3 Roof Trusses (designed according to R802.10.1) 35 # Snow and 90 mph winds (Local Conditions) A6.1 Free text Larry Beesley : Building Open 3 Roof Ventilation as per R806 A6.1 Free text Larry Beesley : Building Open 3 Ground Surface to Slope away from Foundation a minimum of 6" within first 10 ft. A6.1 Free text Larry Beesley : Building Open 3 Minimum Frost Depth Ground Surface to Bottom of Footing 36" A2.1 Stamp Larry Beesley : Building Open 4 Approved - Building Inspector A2.1 Free text Larry Beesley : Building Open 4 FAN A2.1 Free text Larry Beesley : Building Open 4 SD CO A2.1 Free text Larry Beesley : Building Open 4 SD A2.1 Free text Larry Beesley : Building Open 4 SD A2.1 Free text Larry Beesley : Building Open 4 SD A2.1 Free text Larry Beesley : Building Open 4 SD CO A2.1 Free text Larry Beesley : Building Open 4 Attic Access 22"x30" minimum access where attic clear height exceeds 30" (R807) A2.1 Free text Larry Beesley : Building Open 4 Flue chase shown on plans (B-vents not to be inside insulated walls without insulation shield) A2.1 Line Larry Beesley : Building Open 4 A5.1 Stamp Larry Beesley : Building Open 5 Approved - Building Inspector A5.1 Free text Larry Beesley : Building Open 5 Roof Trusses (designed according to R802.10.1) 35 # Snow and 90 mph winds (Local Conditions) Approval of plans does not constitute approval of variance from code Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments A5.1 Free text Larry Beesley : Building Open 5 Stair Rise/Run (7 3/4' max. rise & 10" min. tread, nosing req'd if <11") A5.1 Free text Larry Beesley : Building Open 5 Stairway Headroom (6'8") A5.1 Free text Larry Beesley : Building Open 5 Footing and foundation sizes ? A5.1 Free text Larry Beesley : Building Open 5 2018 IRC Code S1.1 Stamp Larry Beesley : Building Open 6 Approved - Building Inspector S1.1 Free text Larry Beesley : Building Open 6 Ground Surface to Slope away from Foundation a minimum of 6" within first 10 ft. S1.1 Stamp Kyle Baldwin : P&Z Open 6 Approved - Planning and Zoning Approval of plans does not constitute approval of variance from code 1/2" Anchor bolts with 3" x 3" x 1/4" square washers (incl. interior bearing walls) R403.1.6.1 x x x x 4200 LB HOLD DOWNS SD S SD SD CO SD FAN Rebar: 8' Wall-Horizontal & Vertical 24" O.C. with 2 in Top 12" Rebar: 4' Wall-Horizontal & Vertical 24" O.C. with 1 in Top 6" 2018 IRC BUILDING CODE Street Number Displayed on House Roof Ventilation as per R806 Roof Trusses (designed according to R802.10.1) 35 # Snow and 90 mph winds (Local Conditions) Ground Surface to Slope away from Foundation a minimum of 6" within first 10 ft. Minimum Frost Depth Ground Surface to Bottom of Footing 36" Roof Trusses (designed according to R802.10.1) 35 # Snow and 90 mph winds (Local Conditions) Roof Ventilation as per R806 Ground Surface to Slope away from Foundation a minimum of 6" within first 10 ft. Minimum Frost Depth Ground Surface to Bottom of Footing 36" FAN SD CO SD SD SD SD CO Attic Access 22"x30" minimum access where attic clear height exceeds 30" (R807) Flue chase shown on plans (B-vents not to be inside insulated walls without insulation shield) Roof Trusses (designed according to R802.10.1) 35 # Snow and 90 mph winds (Local Conditions) Stair Rise/Run (7 3/4' max. rise & 10" min. tread, nosing req'd if <11") Stairway Headroom (6'8") Footing and foundation sizes ? 2018 IRC Code Ground Surface to Slope away from Foundation a minimum of 6" within first 10 ft.