Loading...
HomeMy WebLinkAboutAPPROVED PLANS - 22-00152 - 1145 S 2nd E - T-Mobile Cell Tower Anchor ProjectAuthor Name Author Email Author Phone No.: Kyle Baldwin Kyle.Baldwin@rexburg.org 208-372-2164 Alex Owens Alex.Owens@rexburg.org 208-372-2330 Cody Jones Cody.Jones@rexburg.org 208-372-2173 Description : RPRXBCA0326100 - T-Mobile Cell Tower Anchor Project Address : 1145 South 200 East Record Type : Cell Tower Document Filename : SL01408C-ID10543-A-03_100%_CD_20220309.pdf Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Approved # 22-00152 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments T-1 Stamp Cody Jones : Building Open 1 Approved - Building Inspector T-1 Stamp Alex Owens : Electrical Open 1 Approved - Electrical Inspector GN-1 Free text Alex Owens : Electrical Open 2 All electrical work to be performed in accordance with 2017 NEC. GN-1 Stamp Alex Owens : Electrical Open 2 Approved - Electrical Inspector E-1 Callout Alex Owens : Electrical Open 12 Supplemental grounding electrode required in both locations unless earth resistance is 25 ohms or less (250.53A2) E-1 Line Alex Owens : Electrical Open 12 E-1 Stamp Alex Owens : Electrical Open 12 Approved - Electrical Inspector A-1 Stamp Kyle Baldwin : P&Z Open 3 Approved - Planning and Zoning Cell Tower Approval of plans does not constitute approval of variance from code Powered by TCPDF (www.tcpdf.org) A l l e l e c t r i c a l w o r k t o b e p e r f o r m e d i n a c c o r d a n c e w i t h 2 0 1 7 N E C . S u p p l e m e n t a l g r o u n d i n g e l e c t r o d e r e q u i r e d i n b o t h l o c a t i o n s u n l e s s e a r t h r e s i s t a n c e i s 2 5 o h m s o r l e s s ( 2 5 0 . 5 3 A 2 ) Exp.06/30/2023 10/18/2021 PARTS LIST NET WT.UNIT WT.LENGTH PART DESCRIPTION PA R T N O . QT Y IT E M 4.80 4.80 7 in CROSSOVER PLATE SC X 2 1 1 1.31 0.66 1/2" X 3" X 5" X 2" U-BOLT (HDG.) X- U B 1 3 0 0 2 2 0.27 0.03 1/2" HDG USS FLATWASHER G1 2 F W 8 3 0.11 0.01 1/2" HDG LOCKWASHER G1 2 L W 8 4 0.57 0.07 1/2'' HDG HEAVY 2H HEX NUT G1 2 N U T 8 5 1.25 0.63 1/2" X 2-1/2" X 4-1/2" X 2" U-BOLT (HDG.) X- U B 1 2 1 2 2 6 DE S C R I P T I O N DR A W I N G U S A G E C H E C K E D B Y ENG. APPROVAL DR A W N B Y DWG. NO. CP D N O . CE K 1 OF 1 BMC 7 / 1 / 2 0 1 1 6/30/2011 SCX2-KCROSSOVERPLATEKIT SHOP SCX2-K CL A S S S U B PART NO.PAGE T O L E R A N C E S O N D I M E N S I O N S , U N L E S S O T H E R W I S E N O T E D A R E : S A W E D , S H E A R E D A N D G A S C U T E D G E S (± 0 .0 3 0 ") D R I L L E D A N D G A S C U T H O L E S (± 0 .0 3 0 ") - N O C O N I N G O F H O L E S L A S E R C U T E D G E S A N D H O L E S (± 0 .0 1 0 ") - N O C O N I N G O F H O L E S B E N D S A R E ± 1 /2 D E G R E E A L L O T H E R M A C H I N I N G (± 0 .0 3 0 ") A L L O T H E R A S S E M B L Y (± 0 .0 6 0 ") TO L E R A N C E N O T E S P R O P R I E T A R Y N O T E : T H E D A T A A N D T E C H N I Q U E S C O N T A I N E D I N T H I S D R A W I N G A R E P R O P R I E T A R Y I N F O R M A T I O N O F V A L M O N T I N D U S T R I E S A N D C O N S I D E R E D A T R A D E S E C R E T . A N Y U S E O R D I S C L O S U R E W I T H O U T T H E C O N S E N T O F V A L M O N T I N D U S T R I E S I S S T R I C T L Y P R O H I B I T E D . Engineering Support Team: 1-888-753-7446 valmontLocations:New York, NY Atlanta, GA Los Angeles, CA Plymouth, IN Salem, OR Dallas, TX 1 2 3 4 5 6 3 4 5 2- 7 / 8 " O . D . A N T E N N A P I P E (O R D E R E D S E P A R A T E L Y ) 2- 3 / 8 " O . D . P I P E (O R D E R E D S E P A R A T E L Y ) TOTAL WT. #8.39 DETAIL A DETAIL B PARTS LIST NET WT.UNIT WT.LENGTHPART DESCRIPTIONPART NO.QTYITEM 5.491.378 1/2 inSTIFF ARM CHANNEL BRACKETX-STU41 39.4119.7172 inDIAGONAL ANGLE - SITE PRO 1X-25492422 12.7212.72 LOWER GATE FOOT WELDMENTCFS13 4.534.5311 1/2 inGATE BACKING BARGBB14 3.721.863 inCHAIN MOUNT TIGHTENER BRACKETSHCM-T25 1.600.40 1/2" x 15" THREADED ROD (HDG.)G12R-1546 1.600.40 1/2" x 12" THREADED ROD (HDG.)G12R-1246 0.330.33 1/2" x 6" GALV. THREADED RODG12R-617 1.640.416 1/2 in1/2'' x 6-1/2" HDG HEX BOLT GR5 FULL THREADG1206548 0.590.151/2 in1/2'' x 1-1/2" HDG HEX BOLT GR5G1211249 0.550.033/32 in1/2" HDG USS FLATWASHERG12FW1610 0.250.011/8 in1/2" HDG LOCKWASHERG12LW1811 1.430.07 1/2'' HDG HEAVY 2H HEX NUTG12NUT2012 A B DESCRIPTION DRAWING USAGE CHECKED BY ENG. APPROVALDRAWN BY DWG. NO. CPD NO. CEK 1 O F 3 BMC 3/23/2017 3/23/2017 SFS-V-L SECTOR FRAME STABILIZER - VERTICAL LONG 5563 CUSTOMER SFS-V-L CLASS SUB PART NO. 81 01 P A G E TOLERANCES ON DIMENSIONS, UNLESS OTHERWISE NOTED ARE: SAWED, SHEARED AND GAS CUT EDGES (± 0.030") DRILLED AND GAS CUT HOLES (± 0.030") - NO CONING OF HOLES LASER CUT EDGES AND HOLES (± 0.010") - NO CONING OF HOLES BENDS ARE ± 1/2 DEGREE ALL OTHER MACHINING (± 0.030") ALL OTHER ASSEMBLY (± 0.060") TOLERANCE NOTES PROPRIETARY NOTE: THE DATA AND TECHNIQUES CONTAINED IN THIS DRAWING ARE PROPRIETARY INFORMATION OF VALMONT INDUSTRIES AND CONSIDERED A TRADE SECRET. ANY USE OR DISCLOSURE WITHOUT THE CONSENT OF VALMONT INDUSTRIES IS STRICTLY PROHIBITED. Engineering Support Team: 1-888-753-7446 valmont Locations: New York, NY Atlanta, GA Los Angeles, CA Plymouth, IN Salem, OR Dallas, TX X2 X2 X4 X2 X2 X2 TOTAL WT. # 76.65 2 3 4 1 8 10 11 12 7 11 12 6 10 11 12 9 11 12 5 SECTOR FRAME REINFORCING KIT ATTACHES TO EITHER EXISTING SECTOR FRAME CROSS ARMS OR TO AN OPTIONAL HORIZONTAL ROUND MEMBER (SHOWN, SOLD SEPARATELY). IF PURCHASING OPTIONAL HORIZONTAL ROUND MEMBER, CORRESPONDING CROSSOVER PLATE KITS WILL NEED TO BE PURCHASED, ONE PER EXISTING ANTENNA MOUNTING PIPE. A CHANGED MAX. DIA. FOR HANDRAIL CONNECTION 5563 BC 10/25/2017 REVISION HISTORY REV DESCRIPTION OF REVISIONS CPD BY DATE PARTS LIST NET WT.UNIT WT.LENGTHPART DESCRIPTIONPART NO.QTYITEM 6.026.028 1/2 inCROSSOVER PLATESCX411 1.950.98 SQUARE U-BOLT 0.5" DIA. X 4.125" IW X 6" IL X 3" TRX-SUB141822 1.190.60 1/2" X 2-1/2" X 4-1/2" X 2" U-BOLT (HDG.)X-UB121223 1.340.67 1/2" X 3" X 5" X 2" U-BOLT (HDG.)X-UB130023 0.270.033/32 in1/2" HDG USS FLATWASHERG12FW84 0.110.011/8 in1/2" HDG LOCKWASHERG12LW85 0.570.07 1/2'' HDG HEAVY 2H HEX NUTG12NUT86 DESCRIPTION DRAWING USAGE CHECKED BY ENG. APPROVALDRAWN BY DWG. NO. CPD NO. CSL 1 O F 1 3RD PARTY BMC 11/12/2018 9/18/2018 SQCX4-K CROSSOVER PLATE KIT W/ SQUARE U-BOLTS AND STD. U-BOLTS CUSTOMER SQCX4-K CLASS SUB PART NO. 87 02 P A G E TOLERANCES ON DIMENSIONS, UNLESS OTHERWISE NOTED ARE: SAWED, SHEARED AND GAS CUT EDGES (“ 0.030") DRILLED AND GAS CUT HOLES (“ 0.030") - NO CONING OF HOLES LASER CUT EDGES AND HOLES (“ 0.010") - NO CONING OF HOLES BENDS ARE “ 1/2 DEGREE ALL OTHER MACHINING (“ 0.030") ALL OTHER ASSEMBLY (“ 0.060") TOLERANCE NOTES PROPRIETARY NOTE: THE DATA AND TECHNIQUES CONTAINED IN THIS DRAWING ARE PROPRIETARY INFORMATION OF VALMONT INDUSTRIES AND CONSIDERED A TRADE SECRET. ANY USE OR DISCLOSURE WITHOUT THE CONSENT OF VALMONT INDUSTRIES IS STRICTLY PROHIBITED. Engineering Support Team: 1-888-753-7446 valmont Locations: New York, NY Atlanta, GA Los Angeles, CA Plymouth, IN Salem, OR Dallas, TX 4" X 4" SQUARE TUBE 2-3/8" OD OR 2-7/8" OD PIPE CONNECTION (ORDER SEPARATELY) 2 4 5 6 3 4 5 6 1 TOTAL WT. #11.35 PARTS LIST NET WT.UNIT WT.LENGTHPART DESCRIPTIONPART NO.QTYITEM 9.379.3712 3/8 inCORNER BENT PLATE - LEFTCBP-L11 9.379.3712 3/8 inCORNER BENT PLATE - RIGHTCBP-R12 4.601.15 5/8" X 3" X 5-1/4" X 2-1/2" U-BOLT (HDG.)X-UB530043 0.560.07 5/8" HDG USS FLATWASHERG58FW84 0.420.03 5/8" HDG LOCKWASHERG58LW165 2.080.13 5/8'' HDG HEAVY 2H HEX NUTG58NUT166 2.170.27 5/8" x 2" HDG A325 HEX BOLTA580287 DESCRIPTION DRAWING USAGE CHECKED BY ENG. APPROVALDRAWN BY DWG. NO. CPD NO. JFS 1 O F 1 5/10/2020 BMC 5/10/2020 3/18/2020 VZWSMART-PLK3 SUPPORT RAIL CORNER BRACKETS (ANGLE & PIPE NOT INCLUDED) SHOP VZWSMART-PLK3 CLASS SUB PART NO. 87 02 P A G E TOLERANCES ON DIMENSIONS, UNLESS OTHERWISE NOTED ARE: SAWED, SHEARED AND GAS CUT EDGES (“ 0.030") DRILLED AND GAS CUT HOLES (“ 0.030") - NO CONING OF HOLES LASER CUT EDGES AND HOLES (“ 0.010") - NO CONING OF HOLES BENDS ARE “ 1/2 DEGREE ALL OTHER MACHINING (“ 0.030") ALL OTHER ASSEMBLY (“ 0.060") TOLERANCE NOTES PROPRIETARY NOTE: THE DATA AND TECHNIQUES CONTAINED IN THIS DRAWING ARE PROPRIETARY INFORMATION OF VALMONT INDUSTRIES AND CONSIDERED A TRADE SECRET. ANY USE OR DISCLOSURE WITHOUT THE CONSENT OF VALMONT INDUSTRIES IS STRICTLY PROHIBITED. Engineering Support Team: 1-888-753-7446 valmont Locations: New York, NY Atlanta, GA Los Angeles, CA Plymouth, IN Salem, OR Dallas, TX TOTAL WT. #28.56 3 4 5 6 7 6 5 2 1 x2 x2 x2 USE ANGLE SIZE AS NEEDED FIELD CUT AND DRILL (ORDERED SEPARATELY) 1 3/4" 1 7/8" 1 3/4" 1 7/8" 1 1/8" 1 1/8" 2 7/8" OD PIPE (ORDERED SEPARATELY) Valmont Site Pro 1 Lori.Espinosa@valmont.com (631) 715-3045 www.sitepro1.com