Loading...
HomeMy WebLinkAboutAPPROVED PLANS - 21-00055 - 941 Oak Hill Way - New SFRAuthor Name Author Email Author Phone No.: Larry Beesley Larry.Beesley@rexburg.org 208-372-2176 Description : 941 Oak Hill Way - New SFR Address : Record Type : New Single Family Residence Document Filename : Haney Permit Set 101520 (1) (2).pdf Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Approved # 21-00055 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments A1 Free text Larry Beesley : Building Open 1 Street Number Displayed on House A1 Free text Larry Beesley : Building Open 1 Ground Surface to Slope away from Foundation a minimum of 6" within first 10 ft. A1 Free text Larry Beesley : Building Open 1 Minimum Frost Depth Ground Surface to Bottom of Footing 36" A2 Free text Larry Beesley : Building Open 2 x x A2 Free text Larry Beesley : Building Open 2 x x A2 Free text Larry Beesley : Building Open 2 x x A2 Free text Larry Beesley : Building Open 2 x x A2 Free text Larry Beesley : Building Open 2 4200 LB HOLD DOWNS A2 Free text Larry Beesley : Building Open 2 x A2 Free text Larry Beesley : Building Open 2 1800lb hold down A3 Free text Larry Beesley : Building Open 3 x A3 Free text Larry Beesley : Building Open 3 1800lb hold down New Single Family Residence Approval of plans does not constitute approval of variance from code Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments A3 Free text Larry Beesley : Building Open 3 There are engineer specks for the sheeting of the garage walls. A4 Free text Larry Beesley : Building Open 4 Roof Trusses (designed according to R802.10.1) 35 # Snow and 90 mph winds (Local Conditions) A5 Free text Larry Beesley : Building Open 5 5' city sidewalk with a 12' green space . Approval of plans does not constitute approval of variance from code Powered by TCPDF (www.tcpdf.org) Elevations Scale: 1/4" & 1/8" =1'-0" on 36" x 24" Paper Scale: 1/8" & 1/16"=1'-0" on 17" x 11" Paper A1 Su n d a n c e dr a f t i n g & d e s i g n PAGE LAYOUT A1-Elevations A2-Foundation/Basement Plan A3-Floor Plan A4-Cross Section A5-Plot Plan Sundance Drafting and Design tries to provide the most accurate information for your house design as possible, if design information is not provided correctly Sundance is not liable. Many factors occur in construction during the building process that change the continuity of this drawing. Due to these factors if the plan is not followed or changes occur after the final print has been given, Sundance Drafting and Design is not liable for those items. Read through all pages provided. Review all the notations and labels on each page. Engineering supersedes all drafting notations. Labeling by County or City Inspectors have to be followed. Footing, Foundation, Rebar, and Shear walls are specified and have to be followed. Floor Layouts and Truss Details are separate from these pages but need to be kept together and followed. If any problems with the plans, please notify Sundance Drafting and Design. The undersigned has looked through these pages and agrees that all discussed between Client/Contractor and Sundance Drafting and Design is noted and correct Please Initial Here These Plans follow the 2015 IRC Codes Permitting and Inspections Section 106,107,108, & 109 1. For a permit you will need 2 sets of the following: House plans, Floor Layout, Truss Details, Rescheck, Heat Loss Analysis, and Engineer Stamp (if needed). 2. Review entire set of plans including the above described with owner/contractor. 3. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. Sundance Drafting and Design is not liable for construction mistakes. 4. This drawing is not to be duplicated without written or verbal consent by Tiffany Stoddart. GENERAL NOTES: 1/4"=1'-0" UNO Co p y r i g h t S u n d a n c e D r a f t i n g & D e s i g n 2 0 2 0 Copyright Sundance Drafting and Design 2020 Copyright Sundance Drafting and Design 2020 1/8"=1'-0" UNO Start Date Permit Set Bid Set 20 8 . 5 2 4 . 2 8 8 0 N EE D AH OU S E P LA N . C O M Rev Rev A5 of Right Elevation Rev Si m p l i c i t y H o m e s Ha n e y R e s i d e n c e 94 1 O a k h i l l W a y Front Elevation Left Elevation Back Elevation 09-22-2020 8' Main Walls 8'-4" Foundation Walls Garage to Match Main TYP 2, 3, 4, 7, & 10:12 Pitch Main, Front and Sides 2:12 Metal Seam Roof 2' - 1 0 " 8' 2' 2' 12 10 12 4 2:12 Metal Seam Roof Horizontal Siding Asphalt Shingles Vertical SidingFalse Dormer 12 7 12 3 12 212 7 12 7 3:12 Pitch 10-05-2020 TOTAL SQ. FTG.= 3821 MAIN FLOOR=1954/1854 INTERIOR BASEMENT=1867/1662 INTERIOR GARAGE=970 8' 8' - 4 " 10-15-2020 PE R M I T S E T 3-2020 Street Number Displayed on House Ground Surface to Slope away from Foundation a minimum of 6" within first 10 ft. Minimum Frost Depth Ground Surface to Bottom of Footing 36" Foundation Plan Scale: 1/4"=1'-0" 36"x24" Size Paper Scale: 1/8"=1'-0" 17"x11" Size Paper A2A2 Su n d a n c e dr a f t i n g & d e s i g n PAGE LAYOUT A1-Elevations A2-Foundation/Basement Plan A3-Floor Plan A4-Cross Section A5-Plot Plan Sundance Drafting and Design tries to provide the most accurate information for your house design as possible, if design information is not provided correctly Sundance is not liable. Many factors occur in construction during the building process that change the continuity of this drawing. Due to these factors if the plan is not followed or changes occur after the final print has been given, Sundance Drafting and Design is not liable for those items. Read through all pages provided. Review all the notations and labels on each page. Engineering supersedes all drafting notations. Labeling by County or City Inspectors have to be followed. Footing, Foundation, Rebar, and Shear walls are specified and have to be followed. Floor Layouts and Truss Details are separate from these pages but need to be kept together and followed. If any problems with the plans, please notify Sundance Drafting and Design. The undersigned has looked through these pages and agrees that all discussed between Client/Contractor and Sundance Drafting and Design is noted and correct Please Initial Here These Plans follow the 2015 IRC Codes Permitting and Inspections Section 106,107,108, & 109 1. For a permit you will need 2 sets of the following: House plans, Floor Layout, Truss Details, Rescheck, Heat Loss Analysis, and Engineer Stamp (if needed). 2. Review entire set of plans including the above described with owner/contractor. 3. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. Sundance Drafting and Design is not liable for construction mistakes. 4. This drawing is not to be duplicated without written or verbal consent by Tiffany Stoddart. GENERAL NOTES: 1/4"=1'-0" UNO Co p y r i g h t S u n d a n c e D r a f t i n g & D e s i g n 2 0 2 0 Copyright Sundance Drafting and Design 2020 Copyright Sundance Drafting and Design 2020 1/8"=1'-0" UNO Start Date Permit Set Bid Set 20 8 . 5 2 4 . 2 8 8 0 N EE D AH OU S E P LA N . C O M Rev Rev A5 of Rev Si m p l i c i t y H o m e s Ha n e y R e s i d e n c e 94 1 O a k h i l l W a y 09-22-2020 5 6 7 8 9 10 11 12 13 Up 14 26 6 8 24 6 8 26 6 8 2468 2x6 Wall 2468 2 0 6 8 206 8 LN 2668 Storage Under Stairs 2668 24 6 8 30 6 8 WH Furnace WS Bedroom 4 10'-1" x 11'-10" 10 CFM Fresh Air Smoke Detector Bedroom 5 11'-10" x 10'-5" 10 CFM Fresh Air Smoke Detector Bedroom 6 13'-0" x 15'-0" 10 CFM Fresh Air Smoke Detector WIC WIC WIC Bath 50 CFM Mech. 3' Clearance in front of Furnace Seismic Straps around WH Storage Family Room 28'-10" x 18'-3" 10 CFM Fresh Air 4" Co n c . P o u r O v e r Undi s t u r b e d S o i l 40 4 0 S V J 40 4 0 S V J 40 4 0 S V J 4040 SV 4040 SV TRIPLE CAR GARAGE 4" CONCRETE SLAB SLOPE CONC. FLOOR TO DRAIN TO GARAGE DOOR Fl o o r J o i s t D i r e c t i o n Fl o o r J o i s t D i r e c t i o n 1 2 " O . C . Fl o o r J o i s t D i r e c t i o n Fl o o r J o i s t D i r e c t i o n 8'-4" Basement F. Walls 3'2'-6"2'-6" 13 ' - 8 " 3' - 6 " 29'-2" 6' 21 ' 6' - 2 " 17 ' - 2 " 16 ' Center of Footing 33 ' - 2 " 7' - 1 0 " 18 ' 64 ' 5' 16'-6"8'4' 28'28'-6" 56'-6" 16 ' - 3 " 12 ' - 1 1 " Center of Footing 35 ' 26 ' - 8 " 2' - 4 " 64 ' 20'-6" 22'-6"13'-6" 11'-3"11'-3"6'-9"6'-9" 36' 56'-6" 29 ' 1' - 1 0 " 11 ' 18 ' 14'6'-6"36' 5' T-Wall 3'-6"3'-6" 4' Cut 18' for Garage Door opening with Req. Blocking Cut 9' for Garage Door opening with Req. Blocking Duct Work Fl o o r J o i s t D i r e c t i o n 8'-7"27'-5" Ce n t e r o f Fo o t i n g 8' Main Walls w/ Vaults 8'-4" Basement Foundation Walls Garage to Match Main TYP 2668 Fl o o r J o i s t D i r e c t i o n 4" B r i c k L e d g e 4" B r i c k L e d g e Cantilever Above 11'-1" Ventilation R408.1 The under-floor space between the bottom of the floor joists and the earth under any building (except space occupied by a basement) shall have ventilation openings through foundation walls or exterior walls. The minimum net area of ventilation opening shall not be less than 1 s/f for each 150 s/f of under floor space area, unless the ground surface is covered by a Class 1 vapor retarder material. If the vapor retarder is used the min. net area of ventilation openings shall not be less than 1 s/f for each 1500 s/f. One such vent shall be within 3' of each corner of building. Header Notes: Headers 4' or less use 1 Ply 9.50 or 2 Ply 2x10 Dim. Lumber Headers 6' or less use 2 Ply 9.50 Headers 8' or less use 3 Ply 9.50 or 2 Ply 11.88 ML Headers 10' or less use 3 Ply 11.88 or 2 Ply 14.00 ML Headers 10' or more refer to TJXpert Layout Exhaust and Ventilation: Whole House Fan 80 CFM Kitchen Fan 100 CFM Laundry 50 CFM Bathrooms 50 CFM Bedrooms 10 CFM fresh air Living Areas 10 CFM fresh air Contractor to indicate location of fans if not indicated on plans already. GFoundation Wall System: 2x6 Treated Sill Plate over Foam Sill Sealer with 1 2" Anchor Bolts @ 32" O.C. 10" Long, 7" Embedded Max. 12" from all Corners or Splices Concrete Wall Greater than 9' need to have an Architects or Engineer Seal 8' & under (1) Horiz. Bar in top 12" and one at mid-height 8'-1" to 9' (1) Horiz. Bar in top 12" & one bar at each third point Min. (2) Anchor Bolts per Sill Plate w/ nut & SQUARE plate Washer 3x3x1 4" Min. For each Bolt over Concrete Foundation wall Consistent w/ 2015 IRC R401-403 With Asphalt Emulsion on Exterior Side over Continuous Concrete Footings Consistent w/ 2015 IRC Section R106.1 over Undisturbed Soil Window Well System: 2015 IRC Code Min. egress window opening will be 5.7 sq. ft 7 Sill height no higher than 44" above FFL Window wells provide a net clear of 9 sq. ft. w/min horiz. projection & width of 36" Exception: Window Wells w/depth greater than 44" will have a permanently affixed ladder or steps. Ladder or Steps 12"-width Inside, 3"-from walls, Spaced no more than 18" O.C. One egress ladder shall be provided within a window well of an unfinished basement J Smoke Alarms 2015 IRC Code Section 106. R314 All smoke alarms shall be listed in accordance with UL 217 & installed in accordance with NFPA 72 -One in each sleeping area -Outside of each separate sleeping area in the immediate vicinity of the bedrooms -On each additional story including un-finish & finished basements and habitable attics but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with splits levels and without an intervening door between the adjacent levels a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. -Alarm devices shall be interconnected with battery backup that the actuation of one alarm will activate all of the alarms S Carbon Monoxide Alarms 2015 IRC Section 106 & R315.1 New Construction an approved carbon monoxide alarm installed outside of each sleeping area in the immediate vicinity of bedroom and dwelling units. They shall be listed as complying with UL 2034 and installed accordingly CM S CM Window Callouts: Width then Height (ex. 3050 is 3'0" wide by 5'0" Tall) Door same SH-is Single Hung DH is Double Hung SV is Side Vent Fix is Fixed or Picture T or Temp is Tempered Safety Glass Tra is Transom 12 ' - 9 " 5' - 1 0 " 16 ' - 5 " 3'-4"13'-2"3'-10"3'-6"8'-8"3'-10"9'-1" 13'-3" 11 ' - 2 " 5' 5' 12 ' 6' - 2 " 7'-1"2'-4"3'-10" 14'-1" Cl o s e t S CM 10 ' - 6 " 2' - 5 " Co F 22 ' - 1 " 2' - 2 " 14'-5" Ce n t e r o f Fo o t i n g Ce n t e r o f Fo o t i n g Cantilever Above 2-6x6 Post over 16x16x8 Conc. Footer 27'-4" 13 ' - 8 " 5' - 1 0 " Center of Footing Beams 10 " 8' - 7 " 2' - 8 " 2-2668 Closet 10-05-2020 TOTAL SQ. FTG.= 3821 MAIN FLOOR=1954/1854 INTERIOR BASEMENT=1867/1662 INTERIOR GARAGE=970 21 ' - 8 " 5' Cut 3' for Passage Opening with Req. Blocking 10-15-2020 2" P o r c h Ca p 2" P o r c h Ca p PE R M I T S E T Beam Sized by Others -determine if Flush w hangers OR exposed x x x x x x x x 4200 LB HOLD DOWNS x 1800lb hold down Main Floor Scale: 1/4"=1'-0" 36"x24" Size Paper Scale: 1/8"=1'-0" 17"x11" Size Paper A3 Su n d a n c e dr a f t i n g & d e s i g n PAGE LAYOUT A1-Elevations A2-Foundation/Basement Plan A3-Floor Plan A4-Cross Section A5-Plot Plan Sundance Drafting and Design tries to provide the most accurate information for your house design as possible, if design information is not provided correctly Sundance is not liable. Many factors occur in construction during the building process that change the continuity of this drawing. Due to these factors if the plan is not followed or changes occur after the final print has been given, Sundance Drafting and Design is not liable for those items. Read through all pages provided. Review all the notations and labels on each page. Engineering supersedes all drafting notations. Labeling by County or City Inspectors have to be followed. Footing, Foundation, Rebar, and Shear walls are specified and have to be followed. Floor Layouts and Truss Details are separate from these pages but need to be kept together and followed. If any problems with the plans, please notify Sundance Drafting and Design. The undersigned has looked through these pages and agrees that all discussed between Client/Contractor and Sundance Drafting and Design is noted and correct Please Initial Here These Plans follow the 2015 IRC Codes Permitting and Inspections Section 106,107,108, & 109 1. For a permit you will need 2 sets of the following: House plans, Floor Layout, Truss Details, Rescheck, Heat Loss Analysis, and Engineer Stamp (if needed). 2. Review entire set of plans including the above described with owner/contractor. 3. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. Sundance Drafting and Design is not liable for construction mistakes. 4. This drawing is not to be duplicated without written or verbal consent by Tiffany Stoddart. GENERAL NOTES: 1/4"=1'-0" UNO Co p y r i g h t S u n d a n c e D r a f t i n g & D e s i g n 2 0 2 0 Copyright Sundance Drafting and Design 2020 Copyright Sundance Drafting and Design 2020 1/8"=1'-0" UNO Start Date Permit Set Bid Set 20 8 . 5 2 4 . 2 8 8 0 N EE D AH OU S E P LA N . C O M Rev Rev A5 of Rev Si m p l i c i t y H o m e s Ha n e y R e s i d e n c e 94 1 O a k h i l l W a y 09-22-2020 18x8 OH Garage Door 9x8 OH Garage Door 3068 w/ 12" SLS 24 6 8 2x6 Wall LN 2468 26 6 8 2 6 6 8 1 2 3 4 5 6 7 8 9 10 11 12 13 2 4 6 8 ØC G A S F P Bu i l t I n s Bu i l t I n s 30 6 8 26 6 8 26 6 8 11" Min. 11" Min. 3 Car Garage 970 Square Feet Ref DW Dn 2-3050 SH 4050 SV T 2 0 4 0 S H 3-4060 F 3050 SH 3050 SH Va u l t Va u l t Vault Vault Master Bath 50 CFM WIC Utility 50 CFM 80 WHF Mud RoomHidden Pantry Entry 8' Flat Ceiling Hall 8' Flat Ceiling Great Room 17'-6" x 18'-11" 10 CFM Fresh Air 8' Vaulted Ceiling Dining 12'-4" x 10'-4" 10 CFM Fresh Air 8' Vaulted Ceiling Kitchen 12'-6" x 17'-6" 100 CFM 8' Vaulted Ceiling 8' Flat Ceiling Bedroom 2 10'-8" x 10'-6" 10 CFM Fresh Air 8' Flat Ceiling Smoke Detector Office 13'-0" x 10'-9" 10 CFM Fresh Air 8' Flat Ceiling Smoke Detector Covered Porch Bath 50 CFM 11" Min. 33 ' 8' 22 ' 14 ' 20'-6" 22'-6"13'-6" 36' 56'-6" 2'-3"9'2'-3"2'-3"18'2'-3" 2' 24 ' - 2 " 39 ' - 6 " 65 ' - 8 " 28'28'-6" 56'-6" 62 ' 8'-5" 5' 2' 25 ' 8' 4'-4"2'-6" 5' 2' - 6 " 5' 6' 4' - 1 0 " 7'-9"7'-4"2'-10" 30 6 8 11 ' - 6 " 3' - 1 0 " 4'3'-6" 3'-6"3'-6" 4' 7" Foundation Ledge 8' Main Walls w/ Vaults 8'-4" Foundation Walls Garage to Match Main TYP 8' - 4 " 19 ' - 2 " 4'-1" 3'-1"1' Duct Work 26 6 8 24 6 8 T 4 0 4 0 F Header Notes: Headers 4' or less use 1 Ply 9.50 or 2 Ply 2x10 Dim. Lumber Headers 6' or less use 2 Ply 9.50 Headers 8' or less use 3 Ply 9.50 or 2 Ply 11.88 ML Headers 10' or less use 3 Ply 11.88 or 2 Ply 14.00 ML Headers 10' or more refer to TJXpert Layout 3' Hallway Clearance 2015 IRC, Section R106 and R311.6 Saftey Glazing 2015 IRC, Sections R106 and R308.4.5 Furnace: Location of furnace and water heater 2015 IRC, Section R106, and M1305 Elevate all sources of ignition in the garage a min. of 18" above the floor 2015 IRC, Sections R106, and M1307.3 Provide a protection post in the garage to prevent vehicle damage to furnace and water heater. 2015 IRC, Section R106, M1307.3.1 Crawl Space: Through Floor min 18"x24" or through perimeter wall min 16"x24" required crawl space opening. If applicable, refer to mechanical code for access requirements where mechanical equipment is located under floors. 2015 IRC, Section R106, R408.4 M1305.1.4 Smoke Alarms 2015 IRC Code Section 106. R314 All smoke alarms shall be listed in accordance with UL 217 & installed in accordance with NFPA 72 -One in each sleeping area -Outside of each separate sleeping area in the immediate vicinity of the bedrooms -On each additional story including un-finish & finished basements and habitable attics but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with splits levels and without an intervening door between the adjacent levels a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. -Alarm devices shall be interconnected with battery backup that the actuation of one alarm will activate all of the alarms S Carbon Monoxide Alarms 2015 IRC Section 106 & R315.1 New Construction an approved carbon monoxide alarm installed outside of each sleeping area in the immediate vicinity of bedroom and dwelling units. They shall be listed as complying with UL 2034 and installed accordingly CM Exhaust and Ventilation: Whole House Fan 80 CFM Kitchen Fan 100 CFM Laundry 50 CFM Bathrooms 50 CFM Bedrooms 10 CFM fresh air Living Areas 10 CFM fresh air Contractor to indicate location of fans if not indicated on plans already. Garage Portals: Alternate Braced Wall Panel Garage Portal Design PFH See Figure R602.10.6.2 Sheet A4 PFH S CM Window Callouts: Width x Height (ex. 3050 is 3'0" wide by 5'0" Tall) Door same SH-is Single Hung DH is Double Hung SV is Side Vent F is Fixed or Picture T or Temp is Tempered Safety Glass Tra is Transom OBS Obscured 15'-2"12'-10"17'-4"11'-2" 5'-10"5'-4"9'-10"7'-6"6'-8"6'-2"2'-10"9'-4"3' 7' 11 ' - 4 " 2' - 6 " 7' - 7 " 11 ' - 7 " 3' - 4 " 4' - 3 " 4'-11"8'-10" 13'-10" 7'7'3'-3"3'-3"6'-10"2' 5' - 1 0 " 14 ' - 1 0 " 18 ' - 1 0 " 3' - 2 " 3' - 2 " Master Bedroom/1 14'-4" x 18'-0" 10 CFM Fresh Air 8' Vaulted Ceiling Smoke Detector 2' - 6 " 7' - 4 " 3' - 4 " 3' - 6 " 22 ' - 1 0 " 5'-6"5'-7"4'-6" 11'-8"3'-6" 2' - 1 0 " 7' - 1 0 " 7'-8" 11 ' - 4 " 4' - 6 " 5'-6"1'-10" 7'-4"3'-10" (2) 6x6 Post S CM 22'-2"6'-6"14' Contractor to locate exact location of req'd 22" x 30" Attic Access Point Min. 30" Vert. Head Room Clearance (2009-R807.1) 1hr Firewall No Penetrations 20min Fire Rated 1-3/8" Solid Door or Equal, Self Close 3'-10" Lo c k e r s Linen 2668 Op. 8'-4"5'-4" 2' 2x 6 W a l l 27'-10" 12 ' 2-6x6 PostCovered Patio 11 ' - 4 " 3' - 6 " 8' - 8 " 14'6'-6" 3068 2' - 6 " 21 ' - 8 " 20 6 8 Linen 20 6 8 6'-6" 20 6 8 60 1 0 F 6068 AtriumBlinds 9' - 4 " 9' - 6 " 5' - 4 " 3' - 2 " 6' - 4 " 3' - 8 " 3' - 8 " 7' - 6 " 10-05-2020 TOTAL SQ. FTG.= 3821 MAIN FLOOR=1954/1854 INTERIOR BASEMENT=1867/1662 INTERIOR GARAGE=970 10-15-2020 CS-PF CS-PF CS-PFCS-PF 2x 6 W a l l 3'x3' Min Landing IBWP 5 4' Ea. Side IBWP 5 4' Ea. Side IBWP 5 4' Ea. Side IB W P 5 4' E a . S i d e IB W P 5 4' E a . S i d e IB W P 5 4' E a . S i d e PE R M I T S E T 3'-4" 4.11 ft x 1800lb hold down There are engineer specks for the sheeting of the garage walls. Cross Section Floor System: Interior Walls: Exterior Walls: Soffit System: A C D B Alternate Reinforcing Bar Size and Spacing Vertical Rebar Only 8" nominal wall thickness 72" Max rebar spacing #4 @ 15" is equal to #5 @ 23" or #6 @ 32" #4 @ 16" is equal to #5 @ 25" or #6 @ 32" #4 @ 16" is equal to #5 @ 25" or #6 @ 36" Load-Bearing Value of Soil (psf) 1500 2000 3000 Conventional Light-frame Construction 1-story 2-story 3-story 4" Brick Veneer over light frame 1-story 2-story 3-story 12 21 32 12 16 24 12 15 23 12 12 17 12 12 16 Table R403.1 Min. Width of Conc. or Masonry Footings (inches) Smoke Alarms 2015 IRC Code Section R314 All smoke alarms shall be listed in accordance with UL 217 & installed in accordance with NFPA 72 -One in each sleeping area -Outside of each separate sleeping area in the immediate vicinity of the bedrooms -On each additional story including un-finish & finished basements and habitable attics but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with splits levels and without an intervening door between the adjacent levels a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. -Alarm devices shall be interconnected with battery backup that the acuation of one alarm will activate all of the alarms S Exhaust and Ventilation: Whole House Fan 80 CFM Kitchen Fan 100 CFM Laundry 50 CFM Bathrooms 50 CFM Bedrooms 10 CFM fresh air Living Areas 10 CFM fresh air Contractor to indicate location of fans if not indicated on plans already. Carbon Monoxide Alarms 2015 IRC Section R315 New Construction an approved carbon monoxide alarm installed outside of each sleeping area in the immediate vicinity of bedroom and dwelling units. They shall be listed as complying with UL 2034 and installed accordingly Fasteners for Preservative treated wood 2015 IRC Code Section R402.1.1 Fastner for Preservative treated wood shall be of hot dipped zinc-coated galvanized steel, stainless steel, silicon bronze or copper. Exceptions: 1. One-half inch (12.7mm) diameter or greater steel bolts. 2. Fasteners other than nail & timber rivets shall be permitted to be of mechanical deposited zinc coated steel with coating weights in accordance with ASTM B695 class 55 min. Frost Protection 403.1.4.1 Except where otherwise protected from frost, foundation walls, piers and other permanent supports of buildings and structures shall be protected from frost by one or more of the following methods: 1. Extended below the frost line specified in Table R301.2 2. Construct in accordance with Section 403.3 3. Construct in accordance with ASCE 32 or 4. Erected on Solid Rock Exceptions: -Protection of freestanding accessory structures with an area of 400 of 600 square feet or less, of light frame construction with an eve height of 10' of less shall not be required. -Decks not supported by a dwelling need not be provided with footings that extend below the frost line. -Footings shall not bear on frozen soil unless the frozen condition is permanent. Ventilation 2015 IRC Section R408 The under-floor space between the bottom of the floor joists and the earth under any building (except space occupied by a basement) shall have ventilation openings through foundation walls or exterior walls. The minimum net area of ventilation opening shall not be less than 1 s/f for each 150/f of under floor space area, unless the ground surface is covered by a Class 1 vapor retarder material. If the vapor retarder is used the min. net area of ventilation openings shall not be less than 1 s/f for each 1500 s/f. One such vent shall be within 3' of each corner of building. CM Basement Furring: F 8" Conc. Walls Not Required Not Required #6 at 36" O.C. Not Required Not Required #6 at 35" O.C. #6 at 32" O.C. Not Required #6 at 35" O.C. #6 at 34" O.C. Max. Wall Height 8' 9' 10' Max. Unbalanced Backfill Height 5' or less 6' 7' 5' or less 6' 7' 8' 7' or less 8' 9' 8' and Under (1) Horizontal Rebar in top 12" and one at mid-height 8' and Greater (1) Horizontal Rebar in top 12" and one bar at each third point Min. Vertical Reiforcement Size & Spacing Table R404.1.2 (3) Reinforced Concrete Foundation Walls GM, GC, SM, SM-SC and ML Soils 45 Cross Section Roof System: 2015 IRC Code Section R801, R901 Architectural Grade, 25 year Asphalt Shingles R905 over #15 building felt over 7/16" Ext. OSB roof sheeting w/Clips & nailed 6" O.C.-Edges, 10" O.C.-field over 2, 3, 4, 7, & 10:12 Pitch Engineered Trusses @ 24" O.C. (Framed According to Engineered Truss Layout) with R-49 Blown in Attic Insulation with 5/8" Sheet Rock on Interior Side Taped Prep'd for Interior Finishes Contractor to indicate 22"x30" Attic Access Location 2015 IRC Ice Protection Ice Barrier consisting of 2 layers of cemented under-layment and extend from the eave's edge 24" min. from inside exterior wall A E D B 12 21 32 12 16 24 12 12 16 12 12 12 S C Us e t h i s t a b l e u n l e s s a s o i l t e s t i s d o n e A4 Su n d a n c e dr a f t i n g & d e s i g n PAGE LAYOUT A1-Elevations A2-Foundation/Basement Plan A3-Floor Plan A4-Cross Section A5-Plot Plan Sundance Drafting and Design tries to provide the most accurate information for your house design as possible, if design information is not provided correctly Sundance is not liable. Many factors occur in construction during the building process that change the continuity of this drawing. Due to these factors if the plan is not followed or changes occur after the final print has been given, Sundance Drafting and Design is not liable for those items. Read through all pages provided. Review all the notations and labels on each page. Engineering supersedes all drafting notations. Labeling by County or City Inspectors have to be followed. Footing, Foundation, Rebar, and Shear walls are specified and have to be followed. Floor Layouts and Truss Details are separate from these pages but need to be kept together and followed. If any problems with the plans, please notify Sundance Drafting and Design. The undersigned has looked through these pages and agrees that all discussed between Client/Contractor and Sundance Drafting and Design is noted and correct Please Initial Here These Plans follow the 2015 IRC Codes Permitting and Inspections Section 106,107,108, & 109 1. For a permit you will need 2 sets of the following: House plans, Floor Layout, Truss Details, Rescheck, Heat Loss Analysis, and Engineer Stamp (if needed). 2. Review entire set of plans including the above described with owner/contractor. 3. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. Sundance Drafting and Design is not liable for construction mistakes. 4. This drawing is not to be duplicated without written or verbal consent by Tiffany Stoddart. GENERAL NOTES: 1/4"=1'-0" UNO Co p y r i g h t S u n d a n c e D r a f t i n g & D e s i g n 2 0 2 0 Copyright Sundance Drafting and Design 2020 Copyright Sundance Drafting and Design 2020 1/8"=1'-0" UNO Start Date Permit Set Bid Set 20 8 . 5 2 4 . 2 8 8 0 N EE D AH OU S E P LA N . C O M 4' Nailing or Screws 7" O.C. Max Horiz. & Vert. Blocks at Drywall Joints for 7" O.C. Screws of Nails Drywall is shown cutaway Overlapped Double Plate 2x6 Exterior wall @16"O.C. with 7/16" Waferboard Drywall & Waterboard not Shown for clarity 2x4 Interior Wall @16" O.C. 4'x8' Shear Panel on Both Sides 4' 8'x8' Shear Panel on Single Side 48 . 5 " t o c n t r IBWP 3 Interior Braced Wall Panel IBWP 2015 IRC Section 602.10.1 BWP 3-Interior Braced Wall Method 3 (IRC R602.10) 2x4 Studs @ 16" O.C. w/7/16" OSB Nailed 5" O.C. and 10" Field IBWP 5-Interior Braced Wall Method 5 1/2" min. Gypsum board 48" length applied to both sides OR 96" to one side covering 3 studs spaced 16" or 2 studs spaced 24" apart, blocked Screwed @7"/7" w/1" Drywall Screws All Vert Joints occur over stud All Hori. Joints blocked w/2x4 blocking Braced Wall Panel BWP 3' Braced Walls at each strap with 7/16" OSB one side, blocked in all joints Nailed @ 6"/12" w/ 8d or Stapled @ 4"/8" w 16 ga. All joints must occur over raming member 6" at edge 12" in field 4' 8d @ 12" O.C. in field 8d Nails @ 6" O.C. @ edge Braced Wall Panel Detail BWP IBWP 5 All exterior wall are braced walls. Rev Rev A5 of Height of Braced Wall Panel SDC A,B, and C Windspeed <110 MPH Sheathed Width 2'-8"2'-8" MIN. WIDTHS AND TIE-DOWN FORCES OF ALTERNATE BRACED WALL PANELS Table R602.10.6.1 Tie-Down Force (lb.) 11 ft. 3'-2" 1800 3000 2200 3600 1800 3000 1800 3000 - - 1 Seismic Design Category and Windspeed 2'-8" 8 ft. 2'-4" 9 ft. 2'-8" 10 ft. 2'-8" Note a 12 ft. 3'-6" R602.10.6.1, Item 1 R602.10.6.1, Item 2 1800 3000 1800 3000 2000 3300 Sheathed Width SDC D,D, and D Windspeed <110 MPH R602.10.6.1, Item 1 R602.10.6.1, Item 2 1800 3000 0 2 Note a - - Scale: 1/4"=1'-0" UNO on 36"x24" Size Paper Scale: 1/8"=1'-0" UNO on 17"x11" Size Paper Rev Si m p l i c i t y H o m e s Ha n e y R e s i d e n c e 94 1 O a k h i l l W a y 2015 IRC Code R602, R608, R703 Vinyl Siding and Brick over Weather Resistive Barrier 7/16" APA OSB & Nailing Pattern 6"-edge 12"-field 2x6 Stud framed @ 24" O.C. UNO with (2) 2x6 Top Plates with (1) 2x6 Bottom Plate with min. R-21 Batt Insulation with 1/2" Sheetrock Inside Occupancy separation between between house, attic, and garage Taped Prep'd for Interior Finishes 2015 IRC Code 2x6 Fascia Board with style "D" Metal Drip Edge with 3/8" Soffit Sheeting with 3" Continuous Soffit Venting with add'l 2x4 Support as Required 2015 IRC Code 2x4 Stud framed @ 24" O.C. with (2) 2x4 Top Plates with (1) 2x4 Bottom Plate with 1/2" Sheetrock Both Sides Taped Prep'd for Interior Finishes 2015 IRC Code Section R502, R503, R504 3/4" T&G OSB Sub-floor Glued & Nailed over 11-7/8 TJI Engineered Floor Joist Series, Placement, & O.C. Spacing as determined & indicated on TJXpert Layout. (Version 6.0 or later) connected to Rim Joist, spliced using gal. metal ties not less than .058" x 1.5" wide fastened w/6 16d nails ea. side over 1/2" Sheetrock on Ceiling Side Taped and Prep'd for Interior Finishes 2015 IRC Code SectionR602.4 2x4 Stud Framed @ 24" O.C. with Bearing Walls @ 16" O.C. with (2) 2x4 Top Plates with (1) 2x4 Bottom Plate with R-13 Batt Insulation with 6-Mill Poly Vapor Barrier with 1/2" Sheetrock on Interior Side Taped and Prep'd for Interior Finishes Stair System: 2015 IRC R302.7, 311.7.2, R311.7 R312.1.3 Eq. Stair Risers 7 3/4" Max. height, Eq. Stair Treads 10" Min. depth over (3) 11.5" MIN. Stair Stringers bolted at bottom with P.T. 2x4 -3 places with 3" x 1 2" Ø bolt and top securely mounted to framing with Simpson A35 Connector at Stairs Stringer to Ledger or alternate approved connection. with Cont. Handrail System mounted 36"above stair plane. with Handrail return to wall. with a Min. 6'-8" Head Clearance above stair plane. with all other Railing System to be min. 42" above FFL & meet current building codes for vert. and horiz. loading. Slate Spacing to no more than 4" sphere to pass thru. 12" Gypsum Board under stairs 2% Slope Max 1 to 48 H GFoundation Wall System: 2x6 Treated Sill Plate over Foam Sill Sealer with 1 2" Anchor Bolts @ 32" O.C. 10" Long, 7" Embedded Max. 12" from all Corners or Splices Concrete Wall Greater than 9' need to have an Architects or Engineer Seal 8' & under (1) Horiz. Bar in top 12" and one at mid-height 8'-1" to 9' (1) Horiz. Bar in top 12" & one bar at each third point Min. (2) Anchor Bolts per Sill Plate w/ nut & SQUARE plate Washer 3x3x1 4" Min. For each Bolt over Concrete Foundation wall Consistent w/ 2015 IRC R401-403 With Asphalt Emulsion on Exterior Side over Continuous Concrete Footings Consistent w/ 2015 IRC Section R106.1 over Undisturbed Soil Window Well System: 2015 IRC Code Min. egress window opening will be 5.7 sq. ft 7 Sill height no higher than 44" above FFL Window wells provide a net clear of 9 sq. ft. w/min horiz. projection & width of 36" Exception: Window Wells w/depth greater than 44" will have a permanently affixed ladder or steps. Ladder or Steps 12"-width Inside, 3"-from walls, Spaced no more than 18" O.C. One egress ladder shall be provided within a window well of an unfinished basement J 09-22-2020 12 3 Family Room WIC Entry Covered PorchGreat Room 11 ' - 2 " 10 ' - 3 1 / 2 " 8' 1' - 2 " 8' - 4 " 8" 18 ' - 3 1 / 2 " 19 ' - 5 1 / 2 " 27 ' - 9 1 / 2 " 28 ' - 5 1 / 2 " (2) #4 Rebar Horiz. Cont. 5" F G 8'-1" to 9' (1) Horiz. Bar in top 12" and one bar at each third point (2) #4 Rebar Horiz. Cont. (2) #4 Rebar Horiz. Cont. AA BB CC DD EE H e a d r o o m H e i g h t H a n d r a i l H e i g h t 4' 7 5 / 1 6 " H 8' - 1 1 / 2 " 4" 15 Steps 8" 8' - 4 " 1' - 2 " 6' - 8 " 3' 10 1/2" 11" Min Run on Conc. Step into house Max Rise 7 3/4" Concrete Steps into House 12 4 12 7 10-05-2020 TOTAL SQ. FTG.= 3821 MAIN FLOOR=1954/1854 INTERIOR BASEMENT=1867/1662 INTERIOR GARAGE=970 10-15-2020 PE R M I T S E T CL Porch to Footing Detail Pre s s u r e T r e a t e d 6 x 6 P o s t ( m i n . ) Wood t o C o n c r e t e C o n n e c t o r (2) #4 Rebar Horiz. Cont. B Pre s s u r e T r e a t e d B e a m Siz e b y T J X p e r t L a y o u t Sim p s o n C o l u m n C a p 30 " M i n Pitch D e t e r m i n e d o n A 1 Fasten sheathing to header w 8d common or gal. box nails in 3" grid pattern as shown Header to jack-stud strap per table R602.10.6.4 on both sides of opening opposite side of sheathing Min. Length of panel per Table R602.10.5 Min. double 2x4 framing covered w min. 716" thick wood structual panel sheathing w 8d common or gal. box nails at 3" o.c. in framing (studs, blocking, and sills) TYP. Min. (2) 1 2" Dia. Anchor Bolts installed per R403.1.6 with 2"x2"x 3 16" Plate Washers Min. Double 2x4 Post Typical Portal Frame Construction If needed, panel splice edges shall occur over & be nailed to common blocking w/in middle 24" of wall mid-height. One row of 3" o.c. nailing is req. in ea. panel edge Extent of Header Single Portal Frame (One Braced Wall Panel) Extent of Header Double Portal Frame (Two Braced Wall Panels) Ma x H e i g h t 1 0 ' - 0 " Min. 3"x11 14" net header (Steel header prohibited) Ma x T o t a l W a l l H e i g h t 1 2 ' - 0 " Min. reinforcing of foundation, (1) #4 bar top & bottom of footing. Lap bars 15" min. 2'-18" finished width for single or double portal Alternate Braced Wall Panel Garage Portal Design CS-PF Figure R602.10.6.4 Pony Wall Height Min. Footing under opening is 12"x12" Tension Strap per Table 602.10.6.4 (On opposite side of Sheathing) Fasten Top Plate to header w/2 Rows of 16D sinker nails at 3" O.C. TYP Min. 7 16" Wood Structural Panel Sheating Roof Trusses (designed according to R802.10.1) 35 # Snow and 90 mph winds (Local Conditions) Plot Plan Pine Brook Estates Div. No. 2, Block No. 4, Lot No. 5 City of Rexburg, Madison County, Idaho NORTH A5 Su n d a n c e dr a f t i n g & d e s i g n PAGE LAYOUT A1-Elevations A2-Foundation/Basement Plan A3-Floor Plan A4-Cross Section A5-Plot Plan Sundance Drafting and Design tries to provide the most accurate information for your house design as possible, if design information is not provided correctly Sundance is not liable. Many factors occur in construction during the building process that change the continuity of this drawing. Due to these factors if the plan is not followed or changes occur after the final print has been given, Sundance Drafting and Design is not liable for those items. Read through all pages provided. Review all the notations and labels on each page. Engineering supersedes all drafting notations. Labeling by County or City Inspectors have to be followed. Footing, Foundation, Rebar, and Shear walls are specified and have to be followed. Floor Layouts and Truss Details are separate from these pages but need to be kept together and followed. If any problems with the plans, please notify Sundance Drafting and Design. The undersigned has looked through these pages and agrees that all discussed between Client/Contractor and Sundance Drafting and Design is noted and correct Please Initial Here These Plans follow the 2015 IRC Codes Permitting and Inspections Section 106,107,108, & 109 1. For a permit you will need 2 sets of the following: House plans, Floor Layout, Truss Details, Rescheck, Heat Loss Analysis, and Engineer Stamp (if needed). 2. Review entire set of plans including the above described with owner/contractor. 3. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. Sundance Drafting and Design is not liable for construction mistakes. 4. This drawing is not to be duplicated without written or verbal consent by Tiffany Stoddart. GENERAL NOTES: 1/4"=1'-0" UNO Co p y r i g h t S u n d a n c e D r a f t i n g & D e s i g n 2 0 2 0 Copyright Sundance Drafting and Design 2020 Copyright Sundance Drafting and Design 2020 1/8"=1'-0" UNO Start Date Permit Set Bid Set 20 8 . 5 2 4 . 2 8 8 0 N EE D AH OU S E P LA N . C O M Rev Rev A5 of Rev Si m p l i c i t y H o m e s Ha n e y R e s i d e n c e 94 1 O a k h i l l W a y 09-22-2020 Scale: 1/32"=1'-0" UNO B Size Paper Scale: 1/16"=1'-0" UNO D Size Paper 10-05-2020 TOTAL SQ. FTG.= 3821 MAIN FLOOR=1954/1854 INTERIOR BASEMENT=1867/1662 INTERIOR GARAGE=970 10-15-2020 PE R M I T S E T 54 ' Location of New Construction O a k h i l l W a y 5 6 ' - 6 " 29'- 7 1 / 2 " 30' 35'-8" 78' 86'-5 " 7 3 . 9 9 ' S 3 9 ° 1 5 ' 1 2 " E 5 5 ' - 3 1 / 2 " Lin e o f R e q u i r e d S e t b a c k 5' 96'-4" 96 ' - 4 " 38'-1 0 " Line o f R e q u i r e d S e t b a c k Li n e o f R e q u i r e d S e t b a c k 187.2 6 ' S 8 9 ° 0 8 ' 0 4 " W 17 2 . 4 0 ' N 3 2 ° 3 0 ' 5 9 " E L = 9 2 . 6 1 ' R = 1 1 8 . 0 0 ' 48 . 4 0 ' N 0 ° 0 0 ' 1 4 " W 27.91' S 51° 09'55" E 6 1 . 9 8 ' S 5 1 ° 0 9 ' 5 5 " E 37'-4 1 / 2 " 19' 33'-2" 7'-10" 18' 43'-8" 1 0 7 ' - 1 0 " 74'-3 1/2" 5 6 ' - 6 " 2 8 ' - 6 " 2 8 ' 14' 35' 26'-8" 2'-4" 1 3 ' - 6 " 2 2 ' - 6 " 2 0 ' - 6 " 1 4 ' 6 ' - 6 " 3 6 ' 29' 1'-10" 25' 7'- 6 " 3 0 ' M A X 3 0 ' 3 0 ' 2 5 ' - 1 1 / 2 " 5' city sidewalk with a 12' green space .