HomeMy WebLinkAboutPLANS - 22-00461 - 2337 W 860 S - ShedSheet:
Scale:
UNIT TOTAL SQ. FTG. =
MAIN FLOOR =
SECOND =
GARAGE =
Rev Date
Rev Date
Rev Date
Rev Date
Rev Date
Rev Date
Rev Date
TOTAL BUILDING SQ. FTG. =
MAIN FLOOR =
SECOND =
GARAGE =
6/23/2022
.
.
.
.
.
.
257
.
.
.
.
.
.
.
Drawn By:
Reviewed By:
Structural
Review:
City Review:
.
.
.
S1Monette Residence: Climate Controlled Shed
2337 W 860 S Rexburg, ID
SITE PLAN
Author
11
0
.
0
0
'
60.00'
60.00'
860 SOUTH STREET
11
0
.
0
0
'
WA
T
E
R
SE
W
E
R
LOT: 14
6,600 sq. ft.
LOT: 15 LOT: 13
SIDEWALK
PARK STRIP
18'-0" WIDE
CONCRETE
DRIVEWAY
CONCRETE
WALK WAY
10'-0"x10'-0"
CONCRETE PAD
HOUSE
GARAGE
9.02
9.00
8.79 9.21
37
.
0
0
37
.
0
0
24
.
8
4
20
.
8
4
20
.
8
4
TR
E
E
TRE
E
18.00
BLOCK: 7
12
.
0
0
42.00
WIDTH
52
.
1
7
DE
P
T
H
LOT: 14
6,600 sq. ft.
10
'
-
0
"
3'
-
0
"
0'
-
8
"
10
"
6" GRAVEL
4" CONCRETE PAD
METAL SEAM ROOF
WRAPED AROUND FASCIA
METAL SEAM ROOF
METAL SEAM ROOF
WRAPPED AROUND
FASCIA
GUTTER WITH DOWNSPOUT
RUNNING INTO A
FRENCH DRAIN SYSTEM
3'
-
0
"
8'
-
0
"
8"
2" / 12"
66
"
18
"
66
"
18
"
6X6 PRESSURE
TREADED POST
W/SIMPSON
STRONG-TIE
#APVB66
6X6 PRESSURE
TREADED POST
W/SIMPSON
STRONG-TIE
#APVB66
GUTTER W/
DOWNSPOUT
RUNNING INTO
A FRENCH
DRAIN SYSTEM
10
'
-
0
"
8'
-
0
"
36
"
48
"
2 " / 1 2 "
GUTTER W/
DOWNSPOUT
RUNNING INTO
A FRENCH
DRAIN SYSTEM
Sheet:
Scale:
UNIT TOTAL SQ. FTG. =
MAIN FLOOR =
SECOND =
GARAGE =
Rev Date
Rev Date
Rev Date
Rev Date
Rev Date
Rev Date
Rev Date
TOTAL BUILDING SQ. FTG. =
MAIN FLOOR =
SECOND =
GARAGE =
6/23/2022
.
.
.
.
.
.
257
.
.
.
.
.
.
.
Drawn By:
Reviewed By:
Structural
Review:
City Review:
.
.
.3/8" = 1'-0"
A1Monette Residence: Climate Controlled Shed
2337 W 860 S Rexburg, ID
ELEVATIONS
Author
3/8" = 1'-0"1 FRONT
3/8" = 1'-0"2 BACK
3/8" = 1'-0"3 RIGHT
3/8" = 1'-0"4 LEFT
32' - 0"
19' - 0"10' - 0"3' - 0"
18" TYP.
6" TYP.
13
'
-
6
"
13
'
-
6
"
32' - 0"
2 1 ' - 1 0 3 1 /3 2 "
NOCH FND. 10"
FOR SLABNO J-BOLTS
3' - 10"11' - 4"3' - 10"10' - 0"3' - 0"
10' - 5"
CS-PF CS-PF
Sheet:
Scale:
UNIT TOTAL SQ. FTG. =
MAIN FLOOR =
SECOND =
GARAGE =
Rev Date
Rev Date
Rev Date
Rev Date
Rev Date
Rev Date
Rev Date
TOTAL BUILDING SQ. FTG. =
MAIN FLOOR =
SECOND =
GARAGE =
6/23/2022
.
.
.
.
.
.
257
.
.
.
.
.
.
.
Drawn By:
Reviewed By:
Structural
Review:
City Review:
.
.
.3/4" = 1'-0"
A3Monette Residence: Climate Controlled Shed
2337 W 860 S Rexburg, ID
FOUNDATION PLAN
Author
3/4" = 1'-0"1 FOUNDATION PLAN
13
'
-
6
"
19' - 0"11' - 3 1/4"
3' - 10"5' - 8"5' - 8"3' - 10"
13
'
-
0
"
11' - 6"
30' - 3 1/4"
6"
6"
3'
-
0
"
11' - 6"
20
5
6
20
5
6
16
4
0
3-2X10 HEADER
6X6 PRESSURE
TREADED POST
W/SIMPSON STRONG-TIE
#APVB66
6X6 PRESSURE
TREADED POST
W/SIMPSON STRONG-TIE
#APVB663-2X10 BEAM
3-2X10 BEAM
Sheet:
Scale:
UNIT TOTAL SQ. FTG. =
MAIN FLOOR =
SECOND =
GARAGE =
Rev Date
Rev Date
Rev Date
Rev Date
Rev Date
Rev Date
Rev Date
TOTAL BUILDING SQ. FTG. =
MAIN FLOOR =
SECOND =
GARAGE =
6/23/2022
.
.
.
.
.
.
257
.
.
.
.
.
.
.
Drawn By:
Reviewed By:
Structural
Review:
City Review:
.
.
.3/4" = 1'-0"
A4Monette Residence: Climate Controlled Shed
2337 W 860 S Rexburg, ID
MAIN FLOOR PLAN
Author
3/4" = 1'-0"1 FIRST FLOOR
EXTERNAL TV SUPPLY
+60"
MINI SPLIT
WA
L
L
M
O
U
N
T
2"x10" RAFTER SYSTEM @16"O.C.
3
A5 SIMPSON H2.5T
SIMPSON H2.5T
1 5 ' - 8 "
1' - 0"
1' - 0"
SEAT CUT
SIMPSON H2.5T HANGER
Sheet:
Scale:
UNIT TOTAL SQ. FTG. =
MAIN FLOOR =
SECOND =
GARAGE =
Rev Date
Rev Date
Rev Date
Rev Date
Rev Date
Rev Date
Rev Date
TOTAL BUILDING SQ. FTG. =
MAIN FLOOR =
SECOND =
GARAGE =
6/23/2022
.
.
.
.
.
.
257
.
.
.
.
.
.
.
Drawn By:
Reviewed By:
Structural
Review:
City Review:
.
.
.As indicated
A5Monette Residence: Climate Controlled Shed
2337 W 860 S Rexburg, ID
DETAILS
Author
3/8" = 1'-0"1 ELECTRICAL PLAN
SIMPSON STRONG-TIE MODEL# APVB66
SIMPSON STRONG-TIE MODEL# H2.5T
3/8" = 1'-0"2 ROOF FRAMING
1/2" = 1'-0"3 RAFTER DETAIL
SEAT CUT RAFTER
SIMPSON H2.5T HANGER
INSTALL H2.5T HANGERS
DIAGONALLY ACROSS FROM
EACH OTHER
Table R602.10.5
MIN. LENGTH OF BRACED
WALL PANELS
Wall height 8ft 9ft 10ft 11ft 12ft
16" 18" 20" 22"* 24"*CS
-
P
F
*=10' is the max wall height allowed but a
pony wall attached up to 12'
Min. (2) 1
2" Dia. Anchor
Bolts installed per
R403.1.6 with 2"x2"x 3
16"
Plate Washers
All information
remains the same
except the Tie Down
Anchor Bolt and single
plate for CS-PF
(Same on both
sides of opening)
Alternate Braced Wall
Panel Garage
Portal Design CS-PF
Figure R602.10.6.4