Loading...
HomeMy WebLinkAboutPLANS - 22-00461 - 2337 W 860 S - ShedSheet: Scale: UNIT TOTAL SQ. FTG. = MAIN FLOOR = SECOND = GARAGE = Rev Date Rev Date Rev Date Rev Date Rev Date Rev Date Rev Date TOTAL BUILDING SQ. FTG. = MAIN FLOOR = SECOND = GARAGE = 6/23/2022 . . . . . . 257 . . . . . . . Drawn By: Reviewed By: Structural Review: City Review: . . . S1Monette Residence: Climate Controlled Shed 2337 W 860 S Rexburg, ID SITE PLAN Author 11 0 . 0 0 ' 60.00' 60.00' 860 SOUTH STREET 11 0 . 0 0 ' WA T E R SE W E R LOT: 14 6,600 sq. ft. LOT: 15 LOT: 13 SIDEWALK PARK STRIP 18'-0" WIDE CONCRETE DRIVEWAY CONCRETE WALK WAY 10'-0"x10'-0" CONCRETE PAD HOUSE GARAGE 9.02 9.00 8.79 9.21 37 . 0 0 37 . 0 0 24 . 8 4 20 . 8 4 20 . 8 4 TR E E TRE E 18.00 BLOCK: 7 12 . 0 0 42.00 WIDTH 52 . 1 7 DE P T H LOT: 14 6,600 sq. ft. 10 ' - 0 " 3' - 0 " 0' - 8 " 10 " 6" GRAVEL 4" CONCRETE PAD METAL SEAM ROOF WRAPED AROUND FASCIA METAL SEAM ROOF METAL SEAM ROOF WRAPPED AROUND FASCIA GUTTER WITH DOWNSPOUT RUNNING INTO A FRENCH DRAIN SYSTEM 3' - 0 " 8' - 0 " 8" 2" / 12" 66 " 18 " 66 " 18 " 6X6 PRESSURE TREADED POST W/SIMPSON STRONG-TIE #APVB66 6X6 PRESSURE TREADED POST W/SIMPSON STRONG-TIE #APVB66 GUTTER W/ DOWNSPOUT RUNNING INTO A FRENCH DRAIN SYSTEM 10 ' - 0 " 8' - 0 " 36 " 48 " 2 " / 1 2 " GUTTER W/ DOWNSPOUT RUNNING INTO A FRENCH DRAIN SYSTEM Sheet: Scale: UNIT TOTAL SQ. FTG. = MAIN FLOOR = SECOND = GARAGE = Rev Date Rev Date Rev Date Rev Date Rev Date Rev Date Rev Date TOTAL BUILDING SQ. FTG. = MAIN FLOOR = SECOND = GARAGE = 6/23/2022 . . . . . . 257 . . . . . . . Drawn By: Reviewed By: Structural Review: City Review: . . .3/8" = 1'-0" A1Monette Residence: Climate Controlled Shed 2337 W 860 S Rexburg, ID ELEVATIONS Author 3/8" = 1'-0"1 FRONT 3/8" = 1'-0"2 BACK 3/8" = 1'-0"3 RIGHT 3/8" = 1'-0"4 LEFT 32' - 0" 19' - 0"10' - 0"3' - 0" 18" TYP. 6" TYP. 13 ' - 6 " 13 ' - 6 " 32' - 0" 2 1 ' - 1 0 3 1 /3 2 " NOCH FND. 10" FOR SLABNO J-BOLTS 3' - 10"11' - 4"3' - 10"10' - 0"3' - 0" 10' - 5" CS-PF CS-PF Sheet: Scale: UNIT TOTAL SQ. FTG. = MAIN FLOOR = SECOND = GARAGE = Rev Date Rev Date Rev Date Rev Date Rev Date Rev Date Rev Date TOTAL BUILDING SQ. FTG. = MAIN FLOOR = SECOND = GARAGE = 6/23/2022 . . . . . . 257 . . . . . . . Drawn By: Reviewed By: Structural Review: City Review: . . .3/4" = 1'-0" A3Monette Residence: Climate Controlled Shed 2337 W 860 S Rexburg, ID FOUNDATION PLAN Author 3/4" = 1'-0"1 FOUNDATION PLAN 13 ' - 6 " 19' - 0"11' - 3 1/4" 3' - 10"5' - 8"5' - 8"3' - 10" 13 ' - 0 " 11' - 6" 30' - 3 1/4" 6" 6" 3' - 0 " 11' - 6" 20 5 6 20 5 6 16 4 0 3-2X10 HEADER 6X6 PRESSURE TREADED POST W/SIMPSON STRONG-TIE #APVB66 6X6 PRESSURE TREADED POST W/SIMPSON STRONG-TIE #APVB663-2X10 BEAM 3-2X10 BEAM Sheet: Scale: UNIT TOTAL SQ. FTG. = MAIN FLOOR = SECOND = GARAGE = Rev Date Rev Date Rev Date Rev Date Rev Date Rev Date Rev Date TOTAL BUILDING SQ. FTG. = MAIN FLOOR = SECOND = GARAGE = 6/23/2022 . . . . . . 257 . . . . . . . Drawn By: Reviewed By: Structural Review: City Review: . . .3/4" = 1'-0" A4Monette Residence: Climate Controlled Shed 2337 W 860 S Rexburg, ID MAIN FLOOR PLAN Author 3/4" = 1'-0"1 FIRST FLOOR EXTERNAL TV SUPPLY +60" MINI SPLIT WA L L M O U N T 2"x10" RAFTER SYSTEM @16"O.C. 3 A5 SIMPSON H2.5T SIMPSON H2.5T 1 5 ' - 8 " 1' - 0" 1' - 0" SEAT CUT SIMPSON H2.5T HANGER Sheet: Scale: UNIT TOTAL SQ. FTG. = MAIN FLOOR = SECOND = GARAGE = Rev Date Rev Date Rev Date Rev Date Rev Date Rev Date Rev Date TOTAL BUILDING SQ. FTG. = MAIN FLOOR = SECOND = GARAGE = 6/23/2022 . . . . . . 257 . . . . . . . Drawn By: Reviewed By: Structural Review: City Review: . . .As indicated A5Monette Residence: Climate Controlled Shed 2337 W 860 S Rexburg, ID DETAILS Author 3/8" = 1'-0"1 ELECTRICAL PLAN SIMPSON STRONG-TIE MODEL# APVB66 SIMPSON STRONG-TIE MODEL# H2.5T 3/8" = 1'-0"2 ROOF FRAMING 1/2" = 1'-0"3 RAFTER DETAIL SEAT CUT RAFTER SIMPSON H2.5T HANGER INSTALL H2.5T HANGERS DIAGONALLY ACROSS FROM EACH OTHER Table R602.10.5 MIN. LENGTH OF BRACED WALL PANELS Wall height 8ft 9ft 10ft 11ft 12ft 16" 18" 20" 22"* 24"*CS - P F *=10' is the max wall height allowed but a pony wall attached up to 12' Min. (2) 1 2" Dia. Anchor Bolts installed per R403.1.6 with 2"x2"x 3 16" Plate Washers All information remains the same except the Tie Down Anchor Bolt and single plate for CS-PF (Same on both sides of opening) Alternate Braced Wall Panel Garage Portal Design CS-PF Figure R602.10.6.4