HomeMy WebLinkAboutTRUSS LAYOUT - 22-00063 - 744 Hillside Dr - New SFRJob
BRETT JENSEN - HEGSTED
Truss
A01
Truss Type
Hip Girder
Qty
1
Ply
2
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:44:56 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-sEvuawLcMK6JDTIAHZ60uTa5At8x2R9LmFHYvnzQzsr
Scale = 1:73.8
T2
T3
T2
B1
W9 W8
W7 W6
W5 W4
W3 W2 W1 W2 W3
W4 W5
W6 W7
W8 W9
HW1 HW1
T1 T1
B1B2B2
A
B
C
D
E F G
H
I
J
K
T S R Q P O N M L
U V W X Y Z AA AB
6x8 6x8
12x12
7x10
4x6
2x4 4x4
7x10
4x8
5x6 7x10
2x4
5x6
4x8
7x10
7x10
4x4
4x6
2x4
12x12
4-1-11
4-1-11
8-3-6
4-1-11
12-5-1
4-1-11
16-6-12
4-1-11
21-0-0
4-5-4
25-5-4
4-5-4
29-6-15
4-1-11
33-8-10
4-1-11
37-10-5
4-1-11
42-0-0
4-1-11
4-1-11
4-1-11
8-3-6
4-1-11
12-5-1
4-1-11
16-6-12
4-1-11
21-0-0
4-5-4
25-5-4
4-5-4
29-6-15
4-1-11
33-8-10
4-1-11
37-10-5
4-1-11
42-0-0
4-1-11
1-0-011-10-912-0-81-0-011-10-98.00 12
Plate Offsets (X,Y)-- [A:Edge,0-5-8], [C:0-5-0,0-4-8], [I:0-5-0,0-4-8], [K:Edge,0-5-8], [N:0-5-0,0-4-8], [P:0-5-0,0-4-8], [R:0-5-0,0-4-8]
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.79
0.92
0.84
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.18
-0.26
0.09
0.09
(loc)
Q-R
Q-R
K
Q-R
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 762 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x6 DF 1800F 1.6E or 2x6 DF SS
BOT CHORD 2x6 DF 1800F 1.6E or 2x6 DF SS
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W9,W8,W7,W6: 2x4 DF Stud/Std
WEDGE
Left: 2x10 DF 1950F 1.7E or SS , Right: 2x10 DF 1950F 1.7E or SS
BRACING-
TOP CHORD Sheathed or 5-10-10 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size) A=6523/0-5-8 (min. 0-3-8), K=3317/0-5-8 (min. 0-1-12)
Max HorzA=300(LC 24)
Max UpliftA=-1105(LC 8), K=-552(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-9457/1592, B-C=-8324/1444, C-D=-7242/1295, D-E=-5563/1052, E-F=-4152/800,
F-G=-4152/800, G-H=-4366/839, H-I=-4626/840, I-J=-4800/832, J-K=-4945/815
BOT CHORD A-U=-1356/7220, T-U=-1356/7220, T-V=-1356/7220, V-W=-1356/7220, S-W=-1356/7220,
S-X=-1207/6866, X-Y=-1207/6866, R-Y=-1207/6866, R-Z=-971/5941, Q-Z=-971/5941,
Q-AA=-697/4563, P-AA=-697/4563, P-AB=-426/3573, O-AB=-426/3573, N-O=-448/3767,
M-N=-494/3917, L-M=-555/3739, K-L=-555/3739
WEBS B-T=-196/1346, B-S=-450/190, C-S=-293/1590, C-R=-1632/416, D-R=-688/3567,
D-Q=-3213/749, E-Q=-775/3717, E-P=-1147/464, F-P=-461/170, G-P=-432/1598,
G-O=-259/784, H-O=-685/338, H-N=-172/483, I-N=-458/242
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-5-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
4) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
5) Provide adequate drainage to prevent water ponding.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.5psf.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1105 lb uplift at joint A and 552 lb uplift at
joint K.
9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
Continued on page 2
Job
BRETT JENSEN - HEGSTED
Truss
A01
Truss Type
Hip Girder
Qty
1
Ply
2
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:44:56 2022 Page 2 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-sEvuawLcMK6JDTIAHZ60uTa5At8x2R9LmFHYvnzQzsr
NOTES-
10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 633 lb down and 115 lb up at 1-11-4, 633 lb down and 115 lb up at 3-11-4
, 633 lb down and 115 lb up at 5-11-4, 633 lb down and 115 lb up at 7-11-4, 633 lb down and 115 lb up at 9-11-4, and 633 lb down and 115 lb up at 11-11-4, and 1888 lb
down and 342 lb up at 13-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
LOAD CASE(S) Standard
1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: A-E=-85, E-G=-85, G-K=-85, A-K=-15
Concentrated Loads (lb)
Vert: T=-633(B) U=-633(B) V=-633(B) W=-633(B) X=-633(B) Y=-633(B) Z=-1888(B)
Job
BRETT JENSEN - HEGSTED
Truss
A02
Truss Type
HIP
Qty
5
Ply
1
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:44:58 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-od0e?cMsuxM1TnSYOz9UzugTehvsWNbdDZmfzfzQzsp
Scale = 1:73.5
T2
T3
T2
B1
W5
W4
W3 W2
W1 W1
W2 W3
W4
W5
T1 T1
B1B1B1 B2
W7 W7
W6 W6
A
B
C
D E F
G
H
I
O N M L
K JP Q R S T U
5x6
5x6
5x6
5x6
5x8
4x8
7x10
3x4
7x10 5x8
4x8
4x4 4x4
3x10 3x10
8-3-0
8-3-0
16-6-0
8-3-0
25-6-0
9-0-0
33-9-0
8-3-0
42-0-0
8-3-0
5-6-0
5-6-0
11-0-0
5-6-0
16-6-0
5-6-0
21-0-0
4-6-0
25-6-0
4-6-0
31-0-0
5-6-0
36-6-0
5-6-0
42-0-0
5-6-0
1-0-012-0-01-0-012-0-08.00 12
Plate Offsets (X,Y)-- [B:0-3-8,0-2-0], [C:0-3-0,0-3-4], [D:0-4-4,0-2-4], [F:0-4-4,0-2-4], [G:0-3-0,0-3-4], [H:0-3-8,0-2-0], [K:0-4-0,0-3-0], [L:0-4-12,Edge], [M:0-4-12,Edge], [N:0-4-0
,0-3-0]
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.67
0.63
0.72
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.29
-0.43
0.13
0.08
(loc)
L-M
L-M
J
M-N
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 267 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W5,W7,W6: 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 3-9-2 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 9-4-14 oc bracing.
WEBS 1 Row at midpt C-M, E-M, E-L, G-L, B-O, H-J
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) O=2085/0-5-8 (min. 0-2-4), J=2085/0-5-8 (min. 0-2-4)
Max HorzO=285(LC 5)
Max UpliftO=-336(LC 8), J=-336(LC 9)
Max GravO=2137(LC 2), J=2137(LC 2)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-531/159, B-C=-2862/512, C-D=-2376/452, D-E=-1879/433, E-F=-1879/433,
F-G=-2376/452, G-H=-2862/512, H-I=-530/158, A-O=-442/158, I-J=-442/158
BOT CHORD N-O=-503/2484, N-P=-360/2279, P-Q=-360/2279, M-Q=-360/2279, M-R=-195/1937,
R-S=-195/1937, L-S=-195/1937, L-T=-184/2192, T-U=-184/2192, K-U=-184/2192,
J-K=-311/2328
WEBS C-N=-100/412, C-M=-672/313, D-M=-145/934, F-L=-145/934, G-L=-672/314, G-K=-100/412,
B-O=-2580/328, H-J=-2580/329
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.5psf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 336 lb uplift at joint O and 336 lb uplift at
joint J.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BRETT JENSEN - HEGSTED
Truss
B01
Truss Type
COMMON GIRDER
Qty
1
Ply
2
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:45:01 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-DCinddOlBskbKEB736iBbXIyyuu4jgN4wW?Ja_zQzsm
Scale = 1:68.1
T2 T2
B1
W1
W2 W3
W4 W5
W2W3
W4W5HW1
HW1
T1 T1
B1
A
B
C
D
E
F
G
H
I
N M L K J
O P Q R S T U V W X Y Z AA AB AC AD
7x10
10x16
10x16
12x12
7x10
12x12
4x6
4x12
7x10
12x12
4x6
4x12
10x16
10x16
5-4-0
5-4-0
10-8-0
5-4-0
16-0-0
5-4-0
21-4-0
5-4-0
26-8-0
5-4-0
32-0-0
5-4-0
5-4-0
5-4-0
10-8-0
5-4-0
16-0-0
5-4-0
21-4-0
5-4-0
26-8-0
5-4-0
32-0-0
5-4-0
1-0-011-8-01-0-08.00 12
Plate Offsets (X,Y)-- [A:Edge,0-5-4], [D:0-5-0,0-4-8], [F:0-5-0,0-4-8], [I:Edge,0-5-4], [K:0-3-8,0-6-0], [M:0-3-8,0-6-0]
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.79
0.79
0.97
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.25
-0.35
0.11
0.11
(loc)
L-M
L-M
I
L-M
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 545 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x6 DF 1800F 1.6E or 2x6 DF SS
BOT CHORD 2x8 DF 1950F 1.7E or 2x8 DF SS
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W4,W5: 2x4 DF Stud/Std
SLIDER Left 2x8 DF 1950F 1.7E or SS -° 2-11-12,
Right 2x8 DF 1950F 1.7E or SS -° 2-11-12
BRACING-
TOP CHORD Sheathed or 3-6-1 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size) A=10237/0-5-8 (req. 0-5-9), I=10336/0-5-8 (req. 0-5-10)
Max HorzA=-290(LC 21)
Max UpliftA=-1746(LC 8), I=-1762(LC 9)
Max GravA=10399(LC 2), I=10501(LC 2)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-14560/2427, B-C=-14492/2446, C-D=-12359/2117, D-E=-9605/1739, E-F=-9605/1739,
F-G=-12364/2117, G-H=-14540/2456, H-I=-14608/2436
BOT CHORD A-O=-2055/11592, O-P=-2055/11592, N-P=-2055/11592, N-Q=-2055/11592, Q-R=-2055/11592,
R-S=-2055/11592, M-S=-2055/11592, M-T=-1726/10283, T-U=-1726/10283, U-V=-1726/10283,
L-V=-1726/10283, L-W=-1619/10288, W-X=-1619/10288, X-Y=-1619/10288, K-Y=-1619/10288,
K-Z=-1867/11633, Z-AA=-1867/11633, AA-AB=-1867/11633, J-AB=-1867/11633,
J-AC=-1867/11633, AC-AD=-1867/11633, I-AD=-1867/11633
WEBS E-L=-1777/10161, F-L=-4103/872, F-K=-736/4414, G-K=-1679/419, G-J=-411/2715,
D-L=-4095/871, D-M=-735/4404, C-M=-1633/411, C-N=-401/2665
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x6 - 2 rows staggered at 0-7-0 oc.
Bottom chords connected as follows: 2x8 - 2 rows staggered at 0-7-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
4) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.5psf.
7) WARNING: Required bearing size at joint(s) A, I greater than input bearing size.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1746 lb uplift at joint A and 1762 lb uplift at
joint I.
9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
Continued on page 2
Job
BRETT JENSEN - HEGSTED
Truss
B01
Truss Type
COMMON GIRDER
Qty
1
Ply
2
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:45:01 2022 Page 2 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-DCinddOlBskbKEB736iBbXIyyuu4jgN4wW?Ja_zQzsm
NOTES-
10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1182 lb down and 203 lb up at 2-0-12, 1182 lb down and 203 lb up at
4-0-12, 1182 lb down and 203 lb up at 6-0-12, 1182 lb down and 203 lb up at 8-0-12, 1181 lb down and 203 lb up at 10-0-12, 1167 lb down and 203 lb up at 12-0-12, 1181
lb down and 203 lb up at 14-0-12, 1182 lb down and 203 lb up at 16-0-12, 1180 lb down and 203 lb up at 18-0-12, 1167 lb down and 203 lb up at 20-0-12, 1181 lb down and
203 lb up at 22-0-12, 1195 lb down and 205 lb up at 24-0-12, 1195 lb down and 205 lb up at 26-0-12, and 1195 lb down and 205 lb up at 28-0-12, and 1195 lb down and
205 lb up at 30-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
LOAD CASE(S) Standard
1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: A-E=-85, E-I=-85, A-I=-15
Concentrated Loads (lb)
Vert: L=-1158(B) O=-1158(B) P=-1158(B) Q=-1158(B) R=-1158(B) S=-1158(B) T=-1158(B) V=-1158(B) W=-1158(B) Y=-1158(B) Z=-1158(B) AA=-1170(B) AB=-1170(B)
AC=-1170(B) AD=-1170(B)
Job
BRETT JENSEN - HEGSTED
Truss
B02
Truss Type
COMMON
Qty
7
Ply
1
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:45:03 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-9bqX2JQ?jU?JZYKWBXkfgyNH9iesBkGNNqUQftzQzsk
Scale = 1:67.7
T2 T2
B1
W1
W2
W3
W2
W3
W5 W5
W4 W4
T1 T1
B1
A
B
C
D
E
J I H G
FKL
7x10
4x6
7x10
3x4 5x8 4x6 4x6
6x8
3x4
6x8
8-0-0
8-0-0
16-0-0
8-0-0
24-0-0
8-0-0
32-0-0
8-0-0
8-0-0
8-0-0
16-0-0
8-0-0
24-0-0
8-0-0
32-0-0
8-0-0
1-0-011-8-01-0-08.00 12
Plate Offsets (X,Y)-- [A:Edge,0-1-14], [E:0-3-8,Edge], [F:Edge,0-1-8], [H:0-4-0,0-3-0]
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.81
0.45
0.37
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.14
-0.21
0.05
0.05
(loc)
H-I
H-I
F
H-I
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 175 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W3: 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt D-H, B-H
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) J=1585/0-5-8 (min. 0-1-12), F=1585/0-5-8 (min. 0-1-12)
Max HorzJ=-276(LC 4)
Max UpliftJ=-275(LC 8), F=-275(LC 9)
Max GravJ=1647(LC 15), F=1647(LC 16)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-2186/359, B-C=-1591/374, C-D=-1591/374, D-E=-2187/359, A-J=-1541/304,
E-F=-1540/304
BOT CHORD I-J=-309/595, I-K=-376/1892, H-K=-376/1892, H-L=-201/1697, G-L=-201/1697,
F-G=-129/395
WEBS C-H=-209/1073, D-H=-795/335, D-G=-9/272, B-H=-795/335, B-I=-9/272, A-I=-135/1381,
E-G=-141/1388
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.5psf.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 275 lb uplift at joint J and 275 lb uplift at joint
F.
6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BRETT JENSEN - HEGSTED
Truss
B03
Truss Type
FLAT GIRDER
Qty
1
Ply
3
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:45:05 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-5zxHT?SFF5F1psUuIxn7mNSgJVD7fZ6fq8zXjlzQzsi
Scale = 1:52.7
W4
T1
W4
B1
T1
B3B2
W3 W1 W2 W1 W2 W1 W2 W1 W2 W1 W2 W1 W2 W1 W3
A B C D E F G H I
R Q P O N M L K J
S T U V W X Y Z
5x6
8x12 8x12
5x6 10x12 MT20HS 10x12 MT20HS7x10
6x8 5x6
5x6
4x4
4x8
7x10 4x4 5x6
6x8
6x8
7x10
4-2-1
4-2-1
8-1-6
3-11-5
12-0-11
3-11-5
16-0-0
3-11-5
19-11-5
3-11-5
23-10-10
3-11-5
27-9-15
3-11-5
32-0-0
4-2-1
4-2-1
4-2-1
8-1-6
3-11-5
12-0-11
3-11-5
16-0-0
3-11-5
19-11-5
3-11-5
23-10-10
3-11-5
27-9-15
3-11-5
32-0-0
4-2-1
2-0-0Plate Offsets (X,Y)-- [B:0-3-8,0-3-0], [E:0-5-0,0-4-8], [H:0-3-8,0-3-0], [J:Edge,0-2-8], [K:0-5-0,0-3-0], [L:0-3-8,0-3-0], [M:0-6-0,0-6-8], [P:0-6-0,0-6-0], [Q:0-5-0,0-3-0]
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.64
0.91
0.67
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-1.02
-1.49
0.12
0.49
(loc)
N
N
J
N
l/defl
>370
>254
n/a
>772
L/d
360
240
n/a
240
PLATES
MT20
MT20HS
Weight: 634 lb FT = 20%
GRIP
220/195
165/146
LUMBER-
TOP CHORD 2x6 DF 1800F 1.6E or 2x6 DF SS
BOT CHORD 2x8 DF 1950F 1.7E or 2x8 DF SS
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W4: 2x6 DF 1800F 1.6E or 2x6 DF SS, W1: 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 4-4-12 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
2-2-0 oc bracing: M-N.
REACTIONS.(lb/size) R=6215/0-5-8 (min. 0-2-3), J=6203/0-5-8 (min. 0-2-3)
Max UpliftR=-964(LC 4), J=-1085(LC 4)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-R=-5649/895, A-S=-14341/2211, B-S=-14341/2211, B-T=-24600/3788, C-T=-24600/3788,
C-U=-31205/4806, D-U=-31205/4806, D-V=-32875/5063, E-V=-32875/5063, E-W=-32875/5063,
F-W=-32875/5063, F-X=-31005/4774, G-X=-31005/4774, G-Y=-24886/3834, H-Y=-24886/3834,
H-Z=-14424/2222, I-Z=-14424/2222, I-J=-5654/1017
BOT CHORD Q-R=-179/1147, P-Q=-2211/14341, O-P=-3851/24988, N-O=-4806/31205, M-N=-4812/31226,
L-M=-3834/24886, K-L=-2222/14424, J-K=-177/1135
WEBS A-Q=-2168/14081, B-Q=-5324/865, B-P=-1691/11000, C-P=-3927/645, C-O=-1019/6633,
D-O=-2192/380, D-N=-274/1783, E-N=-1444/264, F-N=-268/1760, F-M=-2239/386,
G-M=-1008/6561, G-L=-3890/639, H-L=-1720/11164, H-K=-5307/864, I-K=-2182/14182
NOTES-
1) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x6 - 2 rows staggered at 0-7-0 oc.
Bottom chords connected as follows: 2x8 - 2 rows staggered at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
4) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
5) Provide adequate drainage to prevent water ponding.
6) All plates are MT20 plates unless otherwise indicated.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 964 lb uplift at joint R and 1085 lb uplift at
joint J.
10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
Continued on page 2
Job
BRETT JENSEN - HEGSTED
Truss
B03
Truss Type
FLAT GIRDER
Qty
1
Ply
3
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:45:05 2022 Page 2 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-5zxHT?SFF5F1psUuIxn7mNSgJVD7fZ6fq8zXjlzQzsi
NOTES-
11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 647 lb down and 96 lb up at 1-11-4, 647 lb down and 96 lb up at 3-11-4,
647 lb down and 96 lb up at 5-11-4, 647 lb down and 96 lb up at 7-11-4, 647 lb down and 96 lb up at 9-11-4, 647 lb down and 96 lb up at 11-11-4, 647 lb down and 96 lb up
at 13-11-4, 647 lb down and 96 lb up at 15-11-4, 647 lb down and 96 lb up at 17-11-4, 647 lb down and 96 lb up at 19-11-4, 647 lb down and 96 lb up at 21-11-4, 647 lb
down and 96 lb up at 23-11-4, 647 lb down and 96 lb up at 25-11-4, 647 lb down and 96 lb up at 27-11-4, and 647 lb down and 96 lb up at 29-11-4, and 177 lb down and
130 lb up at 31-9-4 on top chord. The design/selection of such connection device(s) is the responsibility of others.
LOAD CASE(S) Standard
1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: A-I=-85, J-R=-15
Concentrated Loads (lb)
Vert: I=-8 B=-617 C=-617 D=-617 E=-617 F=-617 G=-617 H=-617 S=-617 T=-617 U=-617 V=-617 W=-617 X=-617 Y=-617 Z=-617
Job
BRETT JENSEN - HEGSTED
Truss
C01
Truss Type
Hip Girder
Qty
1
Ply
2
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:45:07 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-1M32tgTVmiVl29eHQMpbroXy8J?17WQyISSeoezQzsg
Scale = 1:47.3
T1
T2
T3
B1
W6 W4
W3 W2 W1 W2 W3
W5 W7
HW1 HW2
B2
A
B
C
D E F
G
H
I
N M L K J
O P
7x10
4x6
5x8 5x8
7x10
4x6
3x6
2x4 6x8 7x10
1.5x4
6x8
3x6
2x4
4-11-0
4-11-0
9-10-0
4-11-0
13-11-0
4-1-0
18-0-0
4-1-0
23-0-0
5-0-0
28-0-0
5-0-0
4-11-0
4-11-0
9-10-0
4-11-0
13-11-0
4-1-0
18-0-0
4-1-0
23-0-0
5-0-0
28-0-0
5-0-0
1-1-57-6-17-8-01-0-07-6-18.00 12
Plate Offsets (X,Y)-- [D:0-4-0,0-1-9], [F:0-4-0,0-1-9], [K:0-3-8,0-4-4], [L:0-5-0,0-4-8], [M:0-3-8,0-4-4]
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.87
0.57
0.49
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.14
-0.18
0.06
0.10
(loc)
K-L
K-L
I
L-M
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 382 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x6 DF 1800F 1.6E or 2x6 DF SS
WEBS 2x4 DF Stud/Std *Except*
W2: 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
SLIDER Left 2x6 DF SS or 1800F 1.6E -° 3-0-7,
Right 2x6 DF SS or 1800F 1.6E -° 3-0-4
BRACING-
TOP CHORD Sheathed or 3-9-12 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size) A=4104/0-3-8 (min. 0-2-3), I=4072/0-5-8 (min. 0-2-3)
Max HorzA=188(LC 7)
Max UpliftA=-1671(LC 8), I=-1656(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-5922/2432, B-C=-5807/2454, C-D=-5992/2646, D-E=-5348/2417, E-F=-5348/2417,
F-G=-6033/2662, G-H=-5922/2496, H-I=-6040/2478
BOT CHORD A-N=-1973/4602, M-N=-1973/4602, M-O=-2164/4928, L-O=-2164/4928, L-P=-2091/4953,
K-P=-2091/4953, J-K=-1900/4733, I-J=-1900/4733
WEBS C-N=-353/244, C-M=-569/499, D-M=-1060/2131, D-L=-510/844, E-L=-484/205, F-L=-492/794,
F-K=-1089/2204, G-K=-533/466, G-J=-286/225
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-4-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
4) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
5) Provide adequate drainage to prevent water ponding.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1671 lb uplift at joint A and 1656 lb uplift at
joint I.
9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 2100 lb down and 1095 lb up at
9-10-0, 392 lb down and 253 lb up at 11-10-12, 392 lb down and 253 lb up at 13-11-0, and 392 lb down and 253 lb up at 15-11-4, and
2100 lb down and 1095 lb up at 17-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of
others.
LOAD CASE(S) StandardContinued on page 2
Job
BRETT JENSEN - HEGSTED
Truss
C01
Truss Type
Hip Girder
Qty
1
Ply
2
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:45:07 2022 Page 2 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-1M32tgTVmiVl29eHQMpbroXy8J?17WQyISSeoezQzsg
LOAD CASE(S) Standard
1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: A-D=-85, D-F=-85, F-I=-85, A-I=-15
Concentrated Loads (lb)
Vert: M=-2100(B) L=-392(B) K=-2100(B) O=-392(B) P=-392(B)
Job
BRETT JENSEN - HEGSTED
Truss
C02
Truss Type
ROOF SPECIAL
Qty
1
Ply
1
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:45:09 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-_kBoIMVmIKlTHTofXnr3wDdMa7lXbP1FlmxksWzQzse
Scale = 1:54.4
T1
T2
T3
B1
W5 W3
W2 W1 W2
W4 W6
W9 W10
W7 W8B2
A
B
C D
E
F
L K J I H G
5x8
5x8 5x6
5x8
2x4 5x8
3x6
4x6 3x10
3x6
4x6 2x4
6-2-0
6-2-0
12-4-0
6-2-0
15-6-0
3-2-0
21-9-0
6-3-0
28-0-0
6-3-0
6-2-0
6-2-0
12-4-0
6-2-0
15-6-0
3-2-0
21-9-0
6-3-0
28-0-0
6-3-0
1-1-59-2-19-4-01-0-09-2-18.00 12
Plate Offsets (X,Y)-- [A:Edge,0-1-14], [C:0-4-0,0-1-9], [D:0-3-1,Edge], [F:0-3-8,Edge], [J:0-2-12,0-3-0]
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.62
0.24
0.54
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.07
-0.11
0.03
0.03
(loc)
J-K
J-K
G
J-K
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 169 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std *Except*
W3,W2,W1,W4: 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N
1800F 1.6E
BRACING-
TOP CHORD Sheathed or 4-5-7 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) L=1385/0-3-8 (min. 0-1-8), G=1385/0-5-8 (min. 0-1-8)
Max HorzL=-213(LC 4)
Max UpliftL=-231(LC 8), G=-232(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-1814/294, B-C=-1446/290, C-D=-1076/303, D-E=-1459/291, E-F=-1853/301,
A-L=-1339/252, F-G=-1338/253
BOT CHORD K-L=-228/332, J-K=-301/1407, I-J=-111/1072, H-I=-166/1437
WEBS B-J=-457/243, C-J=-113/351, D-I=-99/344, E-I=-479/249, A-K=-120/1231, F-H=-119/1218
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 231 lb uplift at joint L and 232 lb uplift at joint
G.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BRETT JENSEN - HEGSTED
Truss
C03
Truss Type
ROOF SPECIAL
Qty
2
Ply
1
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:45:11 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-w7JZj2W0qx?BXnx2fCtX?eigCwLa3LWYD4QrxPzQzsc
Scale = 1:60.3
T2 T3
B1
W3
W1 W2
W4
W7 W8
W5 W6
B1B1
A
B
C
D
E
I H G FJ K L M N O
5x6
5x8
6x8
5x8
6x8
4x4
4x6
4x4
4x6
9-4-0
9-4-0
18-8-0
9-4-0
28-0-0
9-4-0
6-11-8
6-11-8
13-11-0
6-11-8
20-11-8
7-0-8
28-0-0
7-0-8
1-1-510-4-111-0-08.00 12
Plate Offsets (X,Y)-- [B:0-4-0,Edge], [D:0-4-0,Edge], [G:0-4-0,0-3-4], [H:0-4-0,0-3-4]
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.74
0.59
0.42
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.21
-0.29
0.05
0.04
(loc)
G-H
G-H
F
G-H
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 153 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W3,W4,W7,W8: 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 4-1-2 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt B-I, D-F
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) F=1385/0-5-8 (min. 0-1-9), I=1385/0-3-8 (min. 0-1-9)
Max HorzI=-242(LC 4)
Max UpliftF=-240(LC 9), I=-239(LC 8)
Max GravF=1476(LC 16), I=1476(LC 15)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-521/182, B-C=-1753/410, C-D=-1784/418, D-E=-588/196, A-I=-458/183, E-F=-498/192
BOT CHORD I-J=-331/1613, J-K=-331/1613, H-K=-331/1613, H-L=-100/1099, L-M=-100/1099,
G-M=-100/1099, G-N=-183/1472, N-O=-183/1472, F-O=-183/1472
WEBS B-H=-425/324, C-H=-233/819, C-G=-243/851, D-G=-452/331, B-I=-1491/206, D-F=-1453/199
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.5psf.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 240 lb uplift at joint F and 239 lb uplift at joint
I.
6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BRETT JENSEN - HEGSTED
Truss
D01
Truss Type
GABLE
Qty
1
Ply
1
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:45:13 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-sWQJ8kYGMYFum45Rmdw?43n4pk8rXHCrgOvy?HzQzsa
Scale = 1:67.2
T1 T1
B1
W1
W2
W1
W2
W4
W3
W4
W3
B1B2
ST7
ST8
ST7
ST8
ST5
ST6
ST4
ST3
ST2
ST1
ST5
ST6
ST4
ST3
ST2
ST1
A
B
C
D
E
F
G
H
I
J
K
AA Z Y X
V U T S R Q
O N M L
AC
AGAD
AB
AF
AE AH
AI
W P
3x4
4x6
3x4
12x12 12x12
7x10 7x10
3x4 3x4
4x12
4x12
4x12
4x12
7-5-0
7-5-0
8-1-0
0-8-0
16-1-0
8-0-0
16-11-0
0-10-0
24-2-0
7-3-0
6-0-8
6-0-8
12-1-0
6-0-8
18-1-8
6-0-8
24-2-0
6-0-8
1-0-011-0-131-0-010.00 12
Plate Offsets (X,Y)-- [B:0-5-0,0-1-12], [J:0-5-0,0-1-12]
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.48
0.16
0.28
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.02
-0.03
0.01
0.02
(loc)
U
U
L
U
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 240 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W2,W4: 2x4 DF Stud/Std
OTHERS 2x4 DF Stud/Std *Except*
ST8: 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
JOINTS 1 Brace at Jt(s): AB, AC, AD, AE, AF, AG, AH, AI
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 7-8-8 except (jt=length) L=7-6-8, O=7-6-8, N=7-6-8, M=7-6-8, W=0-3-8, P=0-3-8.
(lb) - Max HorzAA=-260(LC 4)
Max Uplift All uplift 100 lb or less at joint(s) AA, L, W, P except X=-163(LC 8), O=-154(LC 9)
Max Grav All reactions 250 lb or less at joint(s) Y, Z, N, M, P except AA=394(LC 1), L=397(LC 1), X=445(LC 1),
O=497(LC 1), W=276(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-321/206, B-C=-369/191, C-D=-328/225, D-E=-289/266, E-F=-169/253, F-G=-214/302,
G-H=-310/302, H-I=-347/237, I-J=-390/174, J-K=-320/212, A-AA=-334/203, K-L=-333/207
BOT CHORD Z-AA=-130/273, Y-Z=-130/273, X-Y=-130/273, U-V=-52/283, T-U=-52/283, S-T=-52/283,
R-S=-52/283, Q-R=-52/283
WEBS B-AE=-251/154, B-X=-516/215, J-O=-560/197
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable studs spaced at 2-0-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) AA, L, W, P except
(jt=lb) X=163, O=154.
9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BRETT JENSEN - HEGSTED
Truss
D02
Truss Type
COMMON
Qty
1
Ply
1
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:45:15 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-puY3ZQZXuAVc?OFpu2yTAUtPCXl4??z88iO34AzQzsY
Scale = 1:65.1
T1 T1
B1
W1
W2
W1
W2
W4 W4
W3 W3
B1B2
A
B
C
D
E
I H G FJ K L M N O
3x4
4x6
3x4
5x8 5x8
4x6 4x6
3x6 3x6
8-1-0
8-1-0
16-1-0
8-0-0
24-2-0
8-1-0
6-0-8
6-0-8
12-1-0
6-0-8
18-1-8
6-0-8
24-2-0
6-0-8
1-0-011-0-131-0-010.00 12
Plate Offsets (X,Y)-- [G:0-4-0,0-3-0], [H:0-4-0,0-3-0]
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.55
0.43
0.96
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.12
-0.16
0.03
0.03
(loc)
G-H
G-H
F
G-H
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 144 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W2,W4: 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 5-2-2 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) F=1194/0-5-8 (min. 0-1-8), I=1194/0-5-8 (min. 0-1-8)
Max HorzI=-260(LC 4)
Max UpliftF=-192(LC 9), I=-192(LC 8)
Max GravF=1260(LC 16), I=1260(LC 15)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-506/204, B-C=-1378/382, C-D=-1378/382, D-E=-506/204, A-I=-454/199, E-F=-453/199
BOT CHORD I-J=-258/1192, J-K=-258/1192, H-K=-258/1192, H-L=-50/801, L-M=-50/801, G-M=-50/801,
G-N=-129/1049, N-O=-129/1049, F-O=-129/1049
WEBS C-G=-262/729, D-G=-393/337, C-H=-262/729, B-H=-393/337, B-I=-1120/143, D-F=-1119/143
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.5psf.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) F=192,
I=192.
6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BRETT JENSEN - HEGSTED
Truss
D03
Truss Type
COMMON
Qty
10
Ply
1
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:45:16 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-H56Smla9fTdTdYq0SlTiihPaxx5JkSDHMM7ccczQzsX
Scale = 1:65.1
T1 T1
B1
W1
W2
W1
W2
W4 W4
W3 W3
B1B2
A
B
C
D
E
I H G FJ K L M N O
3x4
4x6
3x4
5x8 5x8
4x6 4x6
3x6 3x6
8-1-0
8-1-0
16-1-0
8-0-0
24-2-0
8-1-0
6-0-8
6-0-8
12-1-0
6-0-8
18-1-8
6-0-8
24-2-0
6-0-8
1-0-011-0-131-0-010.00 12
Plate Offsets (X,Y)-- [G:0-4-0,0-3-0], [H:0-4-0,0-3-0]
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.55
0.43
0.96
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.12
-0.16
0.03
0.03
(loc)
G-H
G-H
F
G-H
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 144 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W2,W4: 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 5-2-2 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) F=1194/0-5-8 (min. 0-1-8), I=1194/0-5-8 (min. 0-1-8)
Max HorzI=-260(LC 4)
Max UpliftF=-192(LC 9), I=-192(LC 8)
Max GravF=1260(LC 16), I=1260(LC 15)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-506/204, B-C=-1378/382, C-D=-1378/382, D-E=-506/204, A-I=-454/199, E-F=-453/199
BOT CHORD I-J=-258/1192, J-K=-258/1192, H-K=-258/1192, H-L=-50/801, L-M=-50/801, G-M=-50/801,
G-N=-129/1049, N-O=-129/1049, F-O=-129/1049
WEBS C-G=-262/729, D-G=-393/337, C-H=-262/729, B-H=-393/337, B-I=-1120/143, D-F=-1119/143
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.5psf.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) F=192,
I=192.
6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BRETT JENSEN - HEGSTED
Truss
D04
Truss Type
COMMON
Qty
6
Ply
1
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:45:18 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-DTECBRcPB5uBss_OZAWAn6VwTlnnCNmaqgcjhVzQzsV
Scale = 1:65.1
T1 T2
B1
W5
W1
W2
W1
W2W3
W6
W4
B2
A
B
C
D
E
I H G FJ K L M N O
3x4
4x6
3x4
5x8 3x4
4x6 4x6
3x6 3x6
7-8-0
7-8-0
15-8-0
8-0-0
23-9-0
8-1-0
5-7-8
5-7-8
11-8-0
6-0-8
17-8-8
6-0-8
23-9-0
6-0-8
1-4-311-0-131-0-010.00 12
Plate Offsets (X,Y)-- [G:0-4-0,0-3-0]
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.55
0.43
0.96
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.12
-0.16
0.03
0.02
(loc)
G-H
G-H
F
G-H
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 143 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W5,W2,W6: 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 5-2-15 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) I=1173/Mechanical, F=1173/Mechanical
Max HorzI=-259(LC 4)
Max UpliftI=-186(LC 8), F=-188(LC 9)
Max GravI=1236(LC 15), F=1239(LC 16)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-335/157, B-C=-1309/368, C-D=-1348/377, D-E=-503/204, A-I=-331/161, E-F=-451/199
BOT CHORD I-J=-243/1117, J-K=-243/1117, H-K=-243/1117, H-L=-45/775, L-M=-45/775, G-M=-45/775,
G-N=-125/1026, N-O=-125/1026, F-O=-125/1026
WEBS C-H=-247/654, B-H=-327/321, C-G=-261/733, D-G=-395/337, B-I=-1207/161, D-F=-1091/137
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.5psf.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) I=186,
F=188.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BRETT JENSEN - HEGSTED
Truss
D05
Truss Type
COMMON
Qty
6
Ply
1
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:45:20 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-9sLyc7dfii8v697nhbYesXaF3YTKgHNtH_5qlOzQzsT
Scale = 1:64.7
T1 T2
B1
W5 W6
W1
W2
W1
W2W3 W4
B2
A
B
C
D
E
I H G FJ K L M N O
3x4
4x6
3x4
5x8 3x6 3x4
4x6 4x6
3x6
7-9-0
7-9-0
15-9-0
8-0-0
23-9-0
8-0-0
5-9-0
5-9-0
11-9-0
6-0-0
17-9-0
6-0-0
23-9-0
6-0-0
1-2-811-0-01-0-010.00 12
Plate Offsets (X,Y)-- [G:0-4-0,0-3-0]
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.54
0.42
0.95
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.12
-0.16
0.03
0.03
(loc)
G-H
G-H
F
G-H
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 143 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W5,W6,W2: 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 5-3-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) F=1173/Mechanical, I=1173/Mechanical
Max HorzI=-257(LC 4)
Max UpliftF=-188(LC 9), I=-187(LC 8)
Max GravF=1238(LC 16), I=1236(LC 15)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-384/172, B-C=-1328/372, C-D=-1352/377, D-E=-496/203, A-I=-367/174, E-F=-446/197
BOT CHORD I-J=-247/1138, J-K=-247/1138, H-K=-247/1138, H-L=-47/779, L-M=-47/779, G-M=-47/779,
G-N=-126/1027, N-O=-126/1027, F-O=-126/1027
WEBS C-H=-252/680, B-H=-350/325, C-G=-261/728, D-G=-391/335, B-I=-1178/154, D-F=-1098/138
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.5psf.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) F=188,
I=187.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BRETT JENSEN - HEGSTED
Truss
D06
Truss Type
Common
Qty
11
Ply
1
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:45:22 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-5FTj1pfwEJOdLTH9o0a6yyfbXM8o8Bz9lHawqGzQzsR
Scale = 1:64.7
T1 T1
B1
W1
W2
W1
W2
W4 W4
W3 W3
B2
A
B
C
D
E
I H G FJ K L M N O
3x4
4x6
3x4
5x8
4x6
3x4
4x6
3x6 3x6
8-0-0
8-0-0
16-0-0
8-0-0
24-0-0
8-0-0
6-0-0
6-0-0
12-0-0
6-0-0
18-0-0
6-0-0
24-0-0
6-0-0
1-0-011-0-01-0-010.00 12
Plate Offsets (X,Y)-- [G:0-4-0,0-3-0]
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.54
0.42
0.95
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.12
-0.16
0.03
0.03
(loc)
G-H
G-H
F
G-H
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 143 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W2,W4: 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 5-2-8 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) F=1185/Mechanical, I=1185/0-5-8 (min. 0-1-8)
Max HorzI=-258(LC 4)
Max UpliftF=-190(LC 9), I=-190(LC 8)
Max GravF=1251(LC 16), I=1251(LC 15)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-498/203, B-C=-1370/380, C-D=-1370/380, D-E=-498/203, A-I=-448/198, E-F=-447/197
BOT CHORD I-J=-256/1183, J-K=-256/1183, H-K=-256/1183, H-L=-49/794, L-M=-49/794, G-M=-49/794,
G-N=-128/1041, N-O=-128/1041, F-O=-128/1041
WEBS C-G=-261/725, D-G=-390/335, C-H=-261/725, B-H=-390/335, B-I=-1116/142, D-F=-1115/142
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.5psf.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) F=190,
I=190.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BRETT JENSEN - HEGSTED
Truss
D07
Truss Type
GABLE
Qty
1
Ply
1
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:45:24 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-2dbTSVgAmxeKanRYwRca1NkwnAs6cGwSCb31u9zQzsP
Scale = 1:64.7
T1 T1
B1
W1
W2
W1
W2
W4
W3
W4
W3
ST7
ST8
ST7
ST8
ST5
ST6
ST4
ST3
ST2
ST1
ST5
ST6
B2
ST4
ST3
ST2
ST1
A
B
C
D
E
F
G
H
I
J
K
Y X W V U T S R Q P O N M L
AA
AEAB
Z
AD
AC AF
AG4x4
4x6
4x4
12x12 12x12
7x10
4x6 4x6
4x12
4x12
4x12
4x12
7x10
8-0-0
8-0-0
16-0-0
8-0-0
24-0-0
8-0-0
6-0-0
6-0-0
12-0-0
6-0-0
18-0-0
6-0-0
24-0-0
6-0-0
1-0-011-0-01-0-010.00 12
Plate Offsets (X,Y)-- [B:0-5-0,0-1-12], [J:0-5-0,0-1-12]
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.62
0.30
0.21
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.05
-0.08
0.03
0.03
(loc)
T
N
L
T
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 238 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W2,W4: 2x4 DF Stud/Std
OTHERS 2x4 DF Stud/Std *Except*
ST8: 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BRACING-
TOP CHORD Sheathed or 5-9-3 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
JOINTS 1 Brace at Jt(s): Z, AA, AB, AC, AD, AE, AF, AG
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) Y=1185/0-3-8 (min. 0-1-8), L=1185/0-3-8 (min. 0-1-8)
Max HorzY=258(LC 5)
Max UpliftY=-190(LC 8), L=-190(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-590/219, B-C=-1221/321, C-D=-1178/383, D-E=-1141/449, E-F=-1036/452,
F-G=-1036/452, G-H=-1141/449, H-I=-1178/383, I-J=-1221/322, J-K=-590/218,
A-Y=-511/212, K-L=-511/211
BOT CHORD X-Y=-247/976, W-X=-247/976, V-W=-247/976, U-V=-243/983, T-U=-46/672, S-T=-46/672,
R-S=-46/672, Q-R=-46/672, P-Q=-46/672, O-P=-122/980, N-O=-123/972, M-N=-123/972,
L-M=-123/972
WEBS F-AA=-344/589, AA-AE=-326/556, P-AE=-320/544, J-P=-328/203, U-AB=-320/544,
Z-AB=-326/556, F-Z=-344/589, B-U=-327/202, Y-AD=-852/107, AC-AD=-873/111,
B-AC=-923/124, J-AF=-923/123, AF-AG=-873/110, L-AG=-852/107
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable studs spaced at 2-0-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) Y=190,
L=190.
9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BRETT JENSEN - HEGSTED
Truss
E01
Truss Type
Roof Special
Qty
1
Ply
2
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:45:27 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-SCGc4Wj23s0vSEA7bZAHf0MUjNoSpScvuZIhVUzQzsM
Scale = 1:72.4
T1
T2
T3
B1
W1 W2 W1
W2
W1
W4 W6
W7 W8
W5
W3
W10
W9
T4
B2
A
B C D
E
F
G
N M L K J I
HO P Q R S T U V W X Y Z AA AB
6x8
7x10 5x8
5x6
6x12 MT20HS 7x10
12x12
12x12
1.5x4
4x8
7x10 7x10 6x12 MT20HS
6x8
2-1-8
2-1-8
6-7-8
4-6-0
11-1-8
4-6-0
15-11-8
4-10-0
20-9-8
4-10-0
25-7-8
4-10-0
2-1-8
2-1-8
6-7-8
4-6-0
11-1-8
4-6-0
15-11-8
4-10-0
20-9-8
4-10-0
25-7-8
4-10-0
10-7-012-0-02-4-012-0-08.00 12
Plate Offsets (X,Y)-- [B:0-8-4,0-2-4], [D:0-6-4,0-2-4], [F:0-3-0,0-3-0], [H:0-5-8,Edge], [I:0-3-8,0-4-8], [J:0-3-8,0-4-8], [K:0-5-0,0-4-8]
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.38
0.65
0.92
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.20
-0.28
0.04
0.09
(loc)
J-K
J-K
H
J-K
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
MT20HS
Weight: 514 lb FT = 20%
GRIP
220/195
165/146
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x6 DF 1800F 1.6E or 2x6 DF SS
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W7,W8: 2x4 DF Stud/Std, W5,W10: 2x6 DF 1800F 1.6E or 2x6 DF SS
BRACING-
TOP CHORD Sheathed or 4-10-10 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt B-M, D-L, A-N
REACTIONS.(lb/size) N=8262/0-4-8 (min. 0-4-8), H=8149/0-5-8 (min. 0-4-7)
Max HorzN=-359(LC 9)
Max UpliftN=-1419(LC 9), H=-1326(LC 9)
Max GravN=8429(LC 2), H=8290(LC 2)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-1746/308, B-C=-3677/668, C-D=-3677/668, D-E=-5703/995, E-F=-7637/1272,
F-G=-8005/1290, A-N=-8168/1379, G-H=-7386/1203
BOT CHORD N-O=-161/375, M-O=-161/375, M-P=-309/1375, P-Q=-309/1375, Q-R=-309/1375,
L-R=-309/1375, L-S=-693/4729, S-T=-693/4729, T-U=-693/4729, K-U=-693/4729,
K-V=-863/6283, V-W=-863/6283, W-X=-863/6283, J-X=-863/6283, J-Y=-1004/6581,
Y-Z=-1004/6581, I-Z=-1004/6581, I-AA=-66/321, AA-AB=-66/321, H-AB=-66/321
WEBS B-M=-5135/926, B-L=-1141/6447, C-L=-420/176, D-L=-2913/616, D-K=-1014/5528,
E-K=-3177/724, E-J=-607/3461, F-J=-463/215, F-I=-320/255, A-M=-1210/7159,
G-I=-1030/6873
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc, 2x6 - 2 rows staggered at 0-9-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-7-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
4) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
5) Provide adequate drainage to prevent water ponding.
6) All plates are MT20 plates unless otherwise indicated.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.5psf.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) N=1419,
H=1326.
10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
Continued on page 2
Job
BRETT JENSEN - HEGSTED
Truss
E01
Truss Type
Roof Special
Qty
1
Ply
2
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:45:27 2022 Page 2 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-SCGc4Wj23s0vSEA7bZAHf0MUjNoSpScvuZIhVUzQzsM
NOTES-
11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1182 lb down and 201 lb up at 1-8-4, 1169 lb down and 201 lb up at 3-8-4
, 1181 lb down and 201 lb up at 5-8-4, 1180 lb down and 201 lb up at 7-8-4, 1169 lb down and 201 lb up at 9-8-4, 1183 lb down and 201 lb up at 11-8-4, 1173 lb down and
202 lb up at 13-8-4, 1174 lb down and 202 lb up at 15-8-4, 1183 lb down and 202 lb up at 17-8-4, 1183 lb down and 202 lb up at 19-8-4, and 1183 lb down and 202 lb up at
21-8-4, and 1183 lb down and 202 lb up at 23-8-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
LOAD CASE(S) Standard
1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: A-B=-85, B-D=-85, D-G=-85, H-N=-15
Concentrated Loads (lb)
Vert: J=-1158(F) O=-1158(F) P=-1158(F) R=-1158(F) S=-1158(F) U=-1158(F) V=-1158(F) X=-1158(F) Y=-1158(F) Z=-1158(F) AA=-1158(F) AB=-1158(F)
Job
BRETT JENSEN - HEGSTED
Truss
G01
Truss Type
Roof Special Structural Gable
Qty
2
Ply
1
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:45:28 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-wOq_Hsjgq98m3OlJ9HhWBDvYYnDWXvn27D1F1wzQzsL
Scale: 1/4"=1'
T2
T3
W1
B1
W5 W4
W3 W2
W7
W6
ST3
ST4ST2
ST1
ST5
ST6
ST7
ST8
ST9
ST10
ST11
T1
B2
A
B
C
D
H G F E
7x10
6x8
3x4 3x4 5x6 4x6
5x8
7-4-0
7-4-0
14-8-0
7-4-0
18-4-8
3-8-8
7-4-0
7-4-0
14-8-0
7-4-0
18-4-8
3-8-8
1-0-07-1-59-7-05.00 12
8.00 12
Plate Offsets (X,Y)-- [F:0-3-0,0-3-0], [I:0-1-15,0-0-12], [R:0-1-15,0-0-12]
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.89
0.27
0.92
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.06
-0.10
0.02
0.02
(loc)
F-G
F-G
E
G
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 154 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W5,W3,W6: 2x4 DF Stud/Std, W7: 2x6 DF 1800F 1.6E or 2x6 DF SS
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 3-8-6 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt D-E
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) E=900/0-5-8 (min. 0-1-8), H=900/0-5-8 (min. 0-1-8)
Max HorzH=342(LC 10)
Max UpliftE=-311(LC 10), H=-122(LC 10)
Max GravE=1117(LC 16), H=1044(LC 16)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-1687/139, B-C=-798/26, A-H=-991/148
BOT CHORD G-H=-408/298, F-G=-407/1472, E-F=-130/534
WEBS B-F=-1049/311, C-F=-95/587, C-E=-1147/278, A-G=0/1214
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
4) Unbalanced snow loads have been considered for this design.
5) All plates are 1.5x4 MT20 unless otherwise indicated.
6) Gable studs spaced at 2-0-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) E=311,
H=122.
10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BRETT JENSEN - HEGSTED
Truss
G02
Truss Type
ROOF SPECIAL
Qty
8
Ply
1
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:45:30 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-snykiYlxMnOUJiuiGij_Ge_u1av_?pGLaXWL6ozQzsJ
Scale = 1:53.0
T2
T3
W1
B1
W5 W4
W3 W2
W7
W6
T1
B2
A
B
C
D
H G F E
7x10
6x8
1.5x4
3x4 3x4 5x6 4x6
5x8
7-4-0
7-4-0
14-8-0
7-4-0
18-4-8
3-8-8
7-4-0
7-4-0
14-8-0
7-4-0
18-4-8
3-8-8
1-0-07-1-59-7-05.00 12
8.00 12
Plate Offsets (X,Y)-- [F:0-3-0,0-3-0]
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.89
0.27
0.92
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.06
-0.10
0.02
0.02
(loc)
F-G
F-G
E
G
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 109 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W5,W3,W6: 2x4 DF Stud/Std, W7: 2x6 DF 1800F 1.6E or 2x6 DF SS
BRACING-
TOP CHORD Sheathed or 3-8-6 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt D-E
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) E=900/0-5-8 (min. 0-1-8), H=900/0-5-8 (min. 0-1-8)
Max HorzH=342(LC 10)
Max UpliftE=-311(LC 10), H=-122(LC 10)
Max GravE=1117(LC 16), H=1044(LC 16)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-1687/139, B-C=-798/26, A-H=-991/148
BOT CHORD G-H=-408/298, F-G=-407/1472, E-F=-130/534
WEBS B-F=-1049/311, C-F=-95/587, C-E=-1147/278, A-G=0/1214
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) E=311,
H=122.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BRETT JENSEN - HEGSTED
Truss
H01
Truss Type
GABLE
Qty
1
Ply
1
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:45:32 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-pA4V7EmBuOeCY?24O6mSM34PTOehTv0e2r?SAhzQzsH
Scale = 1:38.1
W1
T1 T1
W1
B1
ST4 ST4
ST3
ST2
ST1
ST3
ST2
ST1
A
B
C
D
E
F
G
H
I
J
K
U T S R Q P O N M L
3x4
14-4-0
14-4-0
7-2-0
7-2-0
14-4-0
7-2-0
1-0-06-11-111-0-010.00 12
Plate Offsets (X,Y)-- [F:0-2-0,Edge]
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-R
0.19
0.07
0.08
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
n/a
n/a
0.00
(loc)
-
-
L
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 87 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 14-4-0.
(lb) - Max HorzU=-153(LC 4)
Max Uplift All uplift 100 lb or less at joint(s) S except U=-127(LC 6), L=-108(LC 7), R=-117(LC 8), T=-203(LC 8),
O=-119(LC 9), N=-100(LC 9), M=-196(LC 9)
Max Grav All reactions 250 lb or less at joint(s) U, L, Q, P, R, S, T, O, N, M
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
7) Gable studs spaced at 2-0-0 oc.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) S except (jt=lb)
U=127, L=108, R=117, T=203, O=119, N=100, M=196.
11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BRETT JENSEN - HEGSTED
Truss
H02
Truss Type
ROOF SPECIAL
Qty
1
Ply
1
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:45:34 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-lYCFYvoRP?vwnJCTVXowRU9YdCHWxp1xV9UZFazQzsF
Scale = 1:41.5
T1 T1
B1
W1
W3 W3
W2 W2
A
B
C
F E D
6x8
4x6
6x8
2x4 2x4 4x8
7-2-0
7-2-0
14-4-0
7-2-0
7-2-0
7-2-0
14-4-0
7-2-0
1-0-06-11-111-0-010.00 12
Plate Offsets (X,Y)-- [A:Edge,0-1-10], [C:0-3-8,Edge]
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.92
0.24
0.11
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.04
-0.08
0.01
0.00
(loc)
E-F
E-F
D
E
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 74 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 5-6-9 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) F=702/0-5-8 (min. 0-1-8), D=702/0-5-8 (min. 0-1-8)
Max HorzF=-153(LC 4)
Max UpliftF=-110(LC 8), D=-110(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-733/151, B-C=-733/151, A-F=-655/136, C-D=-655/136
BOT CHORD E-F=-277/432, D-E=-177/321
WEBS B-E=0/259
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) F=110,
D=110.
6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BRETT JENSEN - HEGSTED
Truss
H03
Truss Type
COMMON
Qty
15
Ply
1
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:45:35 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-DlldmFp3AJ1nPTnf3FJ9ziijMbdlgGH4kpE6n0zQzsE
Scale = 1:41.5
T1 T1
B1
W1
W3 W3
W2 W2
A
B
C
F E D
6x8
4x6
6x8
2x4 2x4 4x8
7-2-0
7-2-0
14-4-0
7-2-0
7-2-0
7-2-0
14-4-0
7-2-0
1-0-06-11-111-0-010.00 12
Plate Offsets (X,Y)-- [A:Edge,0-1-10], [C:0-3-8,Edge]
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.92
0.24
0.11
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.04
-0.08
0.01
0.00
(loc)
D-E
D-E
D
E
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 74 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 5-6-9 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) F=702/0-3-0 (min. 0-1-8), D=702/0-5-8 (min. 0-1-8)
Max HorzF=-153(LC 4)
Max UpliftF=-110(LC 8), D=-110(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-733/151, B-C=-733/151, A-F=-655/136, C-D=-655/136
BOT CHORD E-F=-277/432, D-E=-177/321
WEBS B-E=0/259
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) F=110,
D=110.
6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BRETT JENSEN - HEGSTED
Truss
H04
Truss Type
Common Supported Gable
Qty
1
Ply
1
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:45:37 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-97tOAxqKiwHUemx2AgLd37nFbPM189GNB7jDsuzQzsC
Scale = 1:38.1
W1
T1 T2
W2
B1
ST4
ST3
ST2
ST1
ST5
ST6
ST7
A
B
C
D
E
F
G
H
I
R Q P O N M L K J
4x6
14-1-0
14-1-0
6-11-0
6-11-0
14-1-0
7-2-0
1-2-86-11-111-0-010.00 12
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-R
0.17
0.06
0.14
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
n/a
n/a
0.00
(loc)
-
-
J
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 80 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 14-1-0.
(lb) - Max HorzR=-152(LC 4)
Max Uplift All uplift 100 lb or less at joint(s) O except R=-132(LC 6), J=-142(LC 7), P=-104(LC 8), Q=-185(LC 8),
M=-111(LC 9), L=-101(LC 9), K=-180(LC 9)
Max Grav All reactions 250 lb or less at joint(s) R, J, N, O, P, Q, M, L, K
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
7) Gable studs spaced at 2-0-0 oc.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) O except (jt=lb)
R=132, J=142, P=104, Q=185, M=111, L=101, K=180.
11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BRETT JENSEN - HEGSTED
Truss
HF01
Truss Type
GABLE
Qty
1
Ply
1
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:45:39 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-6W?8bdsaEYXCu44QI4O58YsduD28c4vgfRCKwnzQzsA
Scale = 1:27.0
T1 T1
B1
ST2
ST1 ST1
A
B
C
D
E
H G F2x4
4x4
2x4 1.5x4 1.5x4
1.5x4
1.5x4
1.5x4
7-11-10
7-11-10
3-11-13
3-11-13
7-11-10
3-11-13
4-1-1212.50 12
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.05
0.01
0.07
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
n/a
n/a
0.00
(loc)
-
-
E
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 34 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 7-11-10.
(lb) - Max HorzA=100(LC 7)
Max Uplift All uplift 100 lb or less at joint(s) A, E except H=-156(LC 8), F=-156(LC 9)
Max Grav All reactions 250 lb or less at joint(s) A, E, G, H, F
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) A, E except (jt=lb)
H=156, F=156.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BRETT JENSEN - HEGSTED
Truss
HF02
Truss Type
GABLE
Qty
1
Ply
1
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:45:40 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-aiZWpztC?rf3VEfdsovKglPoVcOJLX3pt5xtSDzQzs9
Scale = 1:29.2
T1 T1
B1
ST2
ST1 ST1
A
B
C
D
E
H G F2x4
4x4
2x4 1.5x4 1.5x4
1.5x4
1.5x4
1.5x4
8-8-2
8-8-2
4-4-1
4-4-1
8-8-2
4-4-1
4-6-312.50 12
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.06
0.02
0.07
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
n/a
n/a
0.00
(loc)
-
-
E
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 38 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 8-8-2.
(lb) - Max HorzA=-110(LC 6)
Max Uplift All uplift 100 lb or less at joint(s) A, E except H=-170(LC 8), F=-169(LC 9)
Max Grav All reactions 250 lb or less at joint(s) A, E, G except H=260(LC 15), F=260(LC 16)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) A, E except (jt=lb)
H=170, F=169.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BRETT JENSEN - HEGSTED
Truss
J01
Truss Type
Jack-Open
Qty
2
Ply
1
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:45:42 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-W5gHEeuSXTvnlYp?zDxomAU8TQ3vpSM6LPQ_X6zQzs7
Scale = 1:14.3
W2
T1
B1
W1
A
E
D
B
C
1.5x4
4x6
3x4
1-6-13
1-6-13
1-6-13
1-6-13
1-0-02-3-111-9-142-3-1110.00 12
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.03
0.01
0.02
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.00
-0.00
-0.00
0.00
(loc)
E
E
B
E
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 8 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 1-6-13 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) E=71/0-5-8 (min. 0-1-8), B=60/Mechanical, C=11/Mechanical
Max HorzE=48(LC 8)
Max UpliftB=-43(LC 8), C=-21(LC 8)
Max GravE=71(LC 1), B=61(LC 15), C=25(LC 3)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) B, C.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BRETT JENSEN - HEGSTED
Truss
J02
Truss Type
Jack-Open
Qty
2
Ply
1
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:45:43 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-_HEfR_v5Im1eMhOCXwS1IO1HNqPQYvJFa3AX3YzQzs6
Scale = 1:20.9
W2
T1
B1
W1
A
D
C
B
1.5x4
4x6
4x4
3-2-1
3-2-1
3-2-1
3-2-1
1-0-03-7-113-1-143-7-1110.00 12
Plate Offsets (X,Y)-- [C:0-0-10,0-2-0]
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.15
0.06
0.04
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.00
-0.01
-0.00
0.00
(loc)
C-D
C-D
B
D
l/defl
>999
>999
n/a
****
L/d
360
240
n/a
240
PLATES
MT20
Weight: 15 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 3-2-1 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) D=149/0-5-8 (min. 0-1-8), B=126/Mechanical, C=23/Mechanical
Max HorzD=101(LC 8)
Max UpliftB=-90(LC 8), C=-13(LC 8)
Max GravD=149(LC 1), B=128(LC 15), C=53(LC 3)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) B, C.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BRETT JENSEN - HEGSTED
Truss
J03
Truss Type
Jack-Open
Qty
2
Ply
1
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:45:45 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-wgMPsgxLqOHMc?YaeLVVNp6aId3Z0pUY1Nfe8RzQzs4
Scale = 1:27.4
W2
T1
B1
W1
A
D
C
B
1.5x4
4x6
4x4
4-9-4
4-9-4
4-9-4
4-9-4
1-0-04-11-1110.00 12
Plate Offsets (X,Y)-- [C:0-0-11,0-2-0]
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.38
0.14
0.06
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.02
-0.04
-0.00
0.00
(loc)
C-D
C-D
B
D
l/defl
>999
>999
n/a
****
L/d
360
240
n/a
240
PLATES
MT20
Weight: 22 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 4-9-4 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) D=229/0-5-8 (min. 0-1-8), B=194/Mechanical, C=35/Mechanical
Max HorzD=155(LC 8)
Max UpliftB=-139(LC 8), C=-7(LC 8)
Max GravD=229(LC 1), B=197(LC 15), C=81(LC 3)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) C except (jt=lb)
B=139.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BRETT JENSEN - HEGSTED
Truss
J04
Truss Type
Jack-Closed
Qty
2
Ply
1
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:45:47 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-t2UAHMybL?X4rJizmmXzTEBrQRjWUigrUg8lCJzQzs2
Scale = 1:36.0
W3
T1
W1
B1
W2
A
B
C
F E D
1.5x4
4x6
1.5x4
4x6
6-4-7
6-4-7
6-4-7
6-4-7
1-0-06-3-1110.00 12
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.66
0.24
0.08
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.06
-0.11
-0.00
0.00
(loc)
E-F
E-F
E
F
l/defl
>999
>637
n/a
****
L/d
360
240
n/a
240
PLATES
MT20
Weight: 36 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) F=295/0-5-8 (min. 0-1-8), E=328/Mechanical
Max HorzF=210(LC 8)
Max UpliftE=-196(LC 8)
Max GravF=295(LC 1), E=337(LC 15)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-F=-251/0, B-E=-280/196
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) E=196.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BRETT JENSEN - HEGSTED
Truss
J05
Truss Type
Jack-Closed
Qty
5
Ply
1
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:45:49 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-pRcwi2_stcon4drLtBZRYfHI3FRMybb8y_dsHCzQzs0
Scale = 1:43.7
W5
T1
W1
B1
W2W3
W4
A
B
C D
H G F E
1.5x4
4x6
1.5x4
3x6
3x6
4x4
4-0-0
4-0-0
8-0-0
4-0-0
4-0-0
4-0-0
8-0-0
4-0-0
1-0-07-8-010.00 12
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.20
0.09
0.18
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.01
-0.01
-0.00
0.00
(loc)
G-H
G-H
F
G
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 52 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) H=379/0-5-8 (min. 0-1-8), F=407/Mechanical
Max HorzH=266(LC 8)
Max UpliftF=-238(LC 8)
Max GravH=379(LC 1), F=417(LC 15)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-H=-355/0, A-B=-348/0
BOT CHORD G-H=-266/95
WEBS B-F=-340/209
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) F=238.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BRETT JENSEN - HEGSTED
Truss
J06
Truss Type
Jack-Open
Qty
1
Ply
1
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:45:50 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-Hd9IvO_UewweimQYRu4g4spUeeoRh3HHBeMPpezQzs?
Scale: 3/4"=1'
W2
T1
B1
W1
A
D
C
B
1.5x4
5x6
4x4
2-5-12
2-5-12
2-5-12
2-5-12
1-0-02-7-138.00 12
Plate Offsets (X,Y)-- [C:0-0-3,0-2-0]
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.08
0.03
0.02
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.00
-0.00
-0.00
0.00
(loc)
C-D
C-D
B
D
l/defl
>999
>999
n/a
****
L/d
360
240
n/a
240
PLATES
MT20
Weight: 11 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 2-5-12 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) D=114/0-5-8 (min. 0-1-8), B=96/Mechanical, C=17/Mechanical
Max HorzD=62(LC 8)
Max UpliftB=-57(LC 8), C=-11(LC 8)
Max GravD=114(LC 1), B=96(LC 1), C=41(LC 3)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) B, C.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BRETT JENSEN - HEGSTED
Truss
J07
Truss Type
Jack-Open
Qty
1
Ply
1
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:45:52 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-D0H3K30kAXAMx4awZJ789Hvl0SS_9zNaeyrWsXzQzrz
Scale: 1/2"=1'
W2
T1
B1
W1
A
D
C
B
1.5x4
5x6
4x4
4-11-12
4-11-12
4-11-12
4-11-12
1-0-04-3-133-10-104-3-138.00 12
Plate Offsets (X,Y)-- [C:0-0-6,0-2-0]
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.41
0.15
0.05
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.03
-0.05
-0.00
0.00
(loc)
C-D
C-D
B
D
l/defl
>999
>999
n/a
****
L/d
360
240
n/a
240
PLATES
MT20
Weight: 22 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 4-11-12 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) D=239/0-5-8 (min. 0-1-8), B=203/Mechanical, C=36/Mechanical
Max HorzD=130(LC 8)
Max UpliftB=-121(LC 8), C=-1(LC 8)
Max GravD=239(LC 1), B=203(LC 1), C=85(LC 3)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) C except (jt=lb)
B=121.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BRETT JENSEN - HEGSTED
Truss
J08
Truss Type
Jack-Closed
Qty
1
Ply
1
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:45:54 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-9PPpll2_i8Q4BOkJgk9cFi_9CG8gdrdt6GKdxPzQzrx
Scale = 1:34.2
W5
T1
W1
B1
W2W3
W4
A
B
C D
H
G F
E
1.5x4
5x6
1.5x4
3x10
3x6
4x4
4-0-0
4-0-0
7-5-12
3-5-12
4-0-0
4-0-0
7-5-12
3-5-12
1-0-05-11-138.00 12
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.17
0.08
0.13
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.01
-0.01
-0.00
0.00
(loc)
G-H
G-H
F
G
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 45 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) H=350/0-5-8 (min. 0-1-8), F=383/Mechanical
Max HorzH=198(LC 8)
Max UpliftF=-181(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-H=-326/6, A-B=-325/0
WEBS B-F=-332/170
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) F=181.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BRETT JENSEN - HEGSTED
Truss
J09
Truss Type
Jack-Open
Qty
1
Ply
1
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:45:56 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-6nXZAR3FEmgoQhuio9B4K73WJ3rz5nnAZapk?IzQzrv
Scale: 3/4"=1'
W2
T1
B1
W1
A
E
D
C
B
1.5x4
5x6
3x4
2-3-12
2-3-12
2-3-12
2-3-12
1-1-52-7-132-2-102-7-138.00 12
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.07
0.02
0.02
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.00
-0.00
-0.00
0.00
(loc)
E
D-E
B
D
l/defl
>999
>999
n/a
****
L/d
360
240
n/a
240
PLATES
MT20
Weight: 11 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 2-3-12 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) E=105/0-3-8 (min. 0-1-8), B=89/Mechanical, D=17/Mechanical
Max HorzE=57(LC 8)
Max UpliftB=-53(LC 8), D=-15(LC 8)
Max GravE=105(LC 1), B=89(LC 1), D=40(LC 3)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) B, D.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BRETT JENSEN - HEGSTED
Truss
J10
Truss Type
Jack-Open
Qty
1
Ply
1
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:45:57 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-az4yNn4t?3of2rTuLsiJsLcdET9KqEeJoEZHYkzQzru
Scale: 1/2"=1'
W2
T1
B1
W1
A
D
C
B
1.5x4
5x6
4x4
4-9-12
4-9-12
4-9-12
4-9-12
1-1-54-3-133-10-104-3-138.00 12
Plate Offsets (X,Y)-- [C:0-0-5,0-2-0]
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.38
0.14
0.05
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.02
-0.04
-0.00
0.00
(loc)
C-D
C-D
B
D
l/defl
>999
>999
n/a
****
L/d
360
240
n/a
240
PLATES
MT20
Weight: 22 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 4-9-12 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) D=231/0-3-8 (min. 0-1-8), B=196/Mechanical, C=35/Mechanical
Max HorzD=125(LC 8)
Max UpliftB=-116(LC 8), C=-4(LC 8)
Max GravD=231(LC 1), B=196(LC 1), C=82(LC 3)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) C except (jt=lb)
B=116.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BRETT JENSEN - HEGSTED
Truss
J11
Truss Type
Jack-Closed
Qty
1
Ply
1
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:45:59 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-WMCioS57Xh2NH9cGTHlnymh06HswI7ycFY2OcdzQzrs
Scale = 1:34.3
W5
T1
W1
B1
W2W3
W4
A
B
C D
H
G F
E
1.5x4
5x6
1.5x4
3x10
3x6
4x4
3-10-0
3-10-0
7-3-12
3-5-12
3-10-0
3-10-0
7-3-12
3-5-12
1-1-55-11-138.00 12
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.16
0.07
0.12
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.01
-0.01
-0.00
0.00
(loc)
G-H
G-H
F
G
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 45 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) H=342/0-3-8 (min. 0-1-8), F=375/Mechanical
Max HorzH=194(LC 8)
Max UpliftF=-180(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-H=-319/2, A-B=-310/0
WEBS B-F=-318/168
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) F=180.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BRETT JENSEN - HEGSTED
Truss
K01
Truss Type
GABLE
Qty
1
Ply
1
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:46:01 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-SlKSD87N2II4XTmfainF1BnMB4XTm1OvjsXUhVzQzrq
Scale = 1:36.3
W1
T1 T1
W1
B1
ST4 ST4
ST3
ST2
ST1
ST3
ST2
ST1
A
B
C
D
E
F
G
H
I
J K
U T S R Q P O N M L
3x4
13-6-0
13-6-0
6-9-0
6-9-0
13-6-0
6-9-0
1-0-06-7-81-0-010.00 12
Plate Offsets (X,Y)-- [F:0-2-0,Edge]
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-R
0.19
0.07
0.06
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
n/a
n/a
0.00
(loc)
-
-
L
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 81 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 13-6-0.
(lb) - Max HorzU=-144(LC 4)
Max Uplift All uplift 100 lb or less at joint(s) except U=-179(LC 6), L=-155(LC 7), R=-112(LC 8), S=-106(LC 8),
T=-255(LC 8), O=-114(LC 9), N=-106(LC 9), M=-244(LC 9)
Max Grav All reactions 250 lb or less at joint(s) Q, P, R, S, T, O, N, M except U=266(LC 8), L=250(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
7) Gable studs spaced at 2-0-0 oc.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 179 lb uplift at joint U, 155 lb uplift at joint L,
112 lb uplift at joint R, 106 lb uplift at joint S, 255 lb uplift at joint T, 114 lb uplift at joint O, 106 lb uplift at joint N and 244 lb uplift at joint
M.
11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BRETT JENSEN - HEGSTED
Truss
K1HJ
Truss Type
Diagonal Hip Girder
Qty
2
Ply
1
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:46:03 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-P7SDeq9eavYommw2i7pj6csdWu3pEqICAA0blOzQzro
Scale = 1:42.3
W7
T1
W1
B1W6
W5 W4
W3
W2
A
B
C
D E
J I H G F
K
L M N O P Q R
3x6
5x8
3x4
7x10 4x6
3x6
6x8
4x6
4-2-15
4-2-15
8-5-13
4-2-15
12-8-12
4-2-15
4-2-15
4-2-15
8-5-13
4-2-15
12-8-12
4-2-15
1-0-07-7-86.25 12
Plate Offsets (X,Y)-- [H:0-3-8,0-3-0]
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.46
0.71
0.55
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.07
-0.09
0.01
0.06
(loc)
G-H
G-H
G
G-H
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 77 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std *Except*
W7: 2x6 DF 1800F 1.6E or 2x6 DF SS
BRACING-
TOP CHORD Sheathed or 5-1-12 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 7-2-6 oc bracing.
WEBS 1 Row at midpt C-G
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) J=1086/0-7-14 (min. 0-1-8), G=1451/Mechanical
Max HorzJ=265(LC 10)
Max UpliftJ=-484(LC 10), G=-818(LC 10)
Max GravJ=1180(LC 16), G=1733(LC 16)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-J=-1121/465, A-B=-1623/672, B-K=-1212/427, C-K=-1009/437, D-G=-271/81
BOT CHORD J-L=-333/154, L-M=-333/154, I-M=-333/154, I-N=-813/1375, N-O=-813/1375, O-P=-813/1375,
H-P=-813/1375, H-Q=-516/994, Q-R=-516/994, G-R=-516/994
WEBS A-I=-491/1245, B-H=-462/361, C-H=-733/1161, C-G=-1602/834
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 484 lb uplift at joint J and 818 lb uplift at joint
G.
8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 49 lb down and 76 lb up at 2-6-3, 79
lb down and 87 lb up at 3-1-12, 110 lb down and 129 lb up at 5-0-14, 191 lb down and 161 lb up at 6-4-3, 190 lb down and 184 lb up at
7-7-10, and 359 lb down and 205 lb up at 9-6-9, and 308 lb down and 215 lb up at 10-2-6 on bottom chord. The design/selection of
such connection device(s) is the responsibility of others.
10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: A-D=-85, D-E=-85, F-J=-15
Continued on page 2
Job
BRETT JENSEN - HEGSTED
Truss
K1HJ
Truss Type
Diagonal Hip Girder
Qty
2
Ply
1
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:46:03 2022 Page 2 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-P7SDeq9eavYommw2i7pj6csdWu3pEqICAA0blOzQzro
LOAD CASE(S) Standard
Concentrated Loads (lb)
Vert: L=-49(F) M=-79(B) N=-110(F) O=-191(B) P=-190(F) Q=-359(B) R=-308(F)
Job
BRETT JENSEN - HEGSTED
Truss
K02
Truss Type
ROOF SPECIAL
Qty
1
Ply
1
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:46:05 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-LWZz2WAu6XpW?44QpYrBB1xuVhtBirsVdUViqHzQzrm
Scale = 1:40.0
T1 T1
B1
W1
W3 W3
W2 W2
A
B
C
F E D
6x8
4x6
6x8
2x4 2x4 4x8
6-9-0
6-9-0
13-6-0
6-9-0
6-9-0
6-9-0
13-6-0
6-9-0
1-0-06-7-81-0-010.00 12
Plate Offsets (X,Y)-- [A:Edge,0-1-10], [C:0-3-8,Edge]
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.81
0.21
0.10
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.03
-0.06
0.01
0.00
(loc)
E-F
E-F
D
E
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 70 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) F=660/0-5-8 (min. 0-1-8), D=660/0-5-8 (min. 0-1-8)
Max HorzF=-144(LC 4)
Max UpliftF=-103(LC 8), D=-103(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-685/142, B-C=-685/142, A-F=-616/128, C-D=-616/127
BOT CHORD E-F=-250/388, D-E=-156/284
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 103 lb uplift at joint F and 103 lb uplift at joint
D.
6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BRETT JENSEN - HEGSTED
Truss
K03
Truss Type
ROOF SPECIAL
Qty
6
Ply
1
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:46:07 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-HvhkTCC8e83EFODpxzufGS0DuVYmAlPn5o_pu9zQzrk
Scale = 1:40.0
T1 T2
B1
W1
W4
W3
W5
W2
A
B
C
F E D
6x8
4x6
5x8
2x4 2x4 4x8
6-9-0
6-9-0
13-3-0
6-6-0
6-9-0
6-9-0
13-3-0
6-6-0
1-0-06-7-81-2-810.00 12
Plate Offsets (X,Y)-- [A:Edge,0-1-10], [C:0-3-8,Edge]
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.82
0.20
0.09
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.04
-0.06
0.00
0.00
(loc)
E-F
E-F
D
E
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 69 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) F=648/0-5-8 (min. 0-1-8), D=648/Mechanical
Max HorzF=143(LC 5)
Max UpliftF=-101(LC 8), D=-100(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-667/138, B-C=-658/141, C-D=-605/122, A-F=-603/126
BOT CHORD E-F=-255/388
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 101 lb uplift at joint F and 100 lb uplift at joint
D.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BRETT JENSEN - HEGSTED
Truss
K04
Truss Type
COMMON GIRDER
Qty
1
Ply
1
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:46:09 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-DHpUutDOAlJyUhNB2Ow7Mt6W2J9HebH4Y5Twz2zQzri
Scale = 1:39.2
T1 T2
B1
W9
W8
W1
W2W5
W7
W3 W4
W6
A
B
C
D
E
J I H G F
K
6x12
4x4
5x6
5x6 3x10
3x6
4x4
3x6
4x4
3x6
3-4-8
3-4-8
6-9-0
3-4-8
10-0-0
3-3-0
13-3-0
3-3-0
3-4-8
3-4-8
6-9-0
3-4-8
10-0-0
3-3-0
13-3-0
3-3-0
1-0-06-7-81-2-810.00 12
Plate Offsets (X,Y)-- [F:Edge,0-3-8]
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.96
0.52
0.26
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.03
-0.04
0.01
0.01
(loc)
F-G
F-G
F
F-G
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 90 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x6 DF 1800F 1.6E or 2x6 DF SS
WEBS 2x4 DF Stud/Std *Except*
W9: 2x6 DF 1800F 1.6E or 2x6 DF SS
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) F=1903/Mechanical, J=755/0-5-8 (min. 0-1-8)
Max HorzJ=142(LC 5)
Max UpliftF=-327(LC 9), J=-121(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-825/147, B-C=-686/189, C-D=-681/190, D-E=-1155/209, A-J=-715/130, E-F=-978/174
BOT CHORD H-I=-150/578, G-H=-127/828, G-K=-59/260, F-K=-59/260
WEBS C-H=-147/490, A-I=-57/486, D-H=-552/212, D-G=-123/470, E-G=-80/591
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Bearing at joint(s) J considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of
bearing surface.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 327 lb uplift at joint F and 121 lb uplift at joint
J.
8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1412 lb down and 254 lb up at
12-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
LOAD CASE(S) Standard
1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: A-C=-85, C-E=-85, F-J=-15
Concentrated Loads (lb)
Vert: K=-1370
Job
BRETT JENSEN - HEGSTED
Truss
L01
Truss Type
SCISSOR STRUCTURAL
Qty
1
Ply
1
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:46:10 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-hUNs6DE1x3Rp6ryOc5RMu4em1ib1N3NEnlCTVUzQzrh
Scale = 1:37.9
T1 T1
B1 B1
W1
W3 W3
ST2
ST1
ST2
ST1
W2 W2
A
B
C
F
E
D
5x8
4x6
5x8
2x4
5x8
2x4
6-3-0
6-3-0
12-6-0
6-3-0
6-3-0
6-3-0
12-6-0
6-3-0
1-0-06-2-81-0-02-4-1510.00 12
5.00 12
Plate Offsets (X,Y)-- [A:Edge,0-1-10], [C:0-3-8,Edge]
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.69
0.17
0.21
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.04
-0.08
0.03
0.01
(loc)
D-E
D-E
D
E
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 72 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 5-7-14 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) F=610/0-3-8 (min. 0-1-8), D=610/0-5-8 (min. 0-1-8)
Max HorzF=-133(LC 4)
Max UpliftF=-94(LC 8), D=-94(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-943/118, B-C=-941/170, A-F=-652/202, C-D=-651/165
BOT CHORD E-F=-225/364, D-E=-128/257
WEBS B-E=-16/470, A-E=0/397, C-E=-100/456
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable studs spaced at 2-0-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
8) Bearing at joint(s) F, D considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity
of bearing surface.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 94 lb uplift at joint F and 94 lb uplift at joint
D.
10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BRETT JENSEN - HEGSTED
Truss
L02
Truss Type
SCISSORS
Qty
10
Ply
1
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:46:12 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-esUdXvFHTghXL96mkWUqzVk6XWGVrztWE3haaNzQzrf
Scale = 1:37.9
T1 T1
B1 B1
W1
W3 W3
W2 W2
A
B
C
F
E
D
5x8
4x6
5x8
2x4
5x8
2x4
6-3-0
6-3-0
12-6-0
6-3-0
6-3-0
6-3-0
12-6-0
6-3-0
1-0-06-2-81-0-02-4-1510.00 12
5.00 12
Plate Offsets (X,Y)-- [A:Edge,0-1-10], [C:0-3-8,Edge]
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.69
0.17
0.21
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.04
-0.08
0.03
0.01
(loc)
D-E
D-E
D
E
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 64 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 5-7-14 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) F=610/0-3-8 (min. 0-1-8), D=610/0-5-8 (min. 0-1-8)
Max HorzF=-133(LC 6)
Max UpliftF=-94(LC 8), D=-94(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-943/118, B-C=-941/170, A-F=-652/202, C-D=-651/165
BOT CHORD E-F=-225/364, D-E=-128/257
WEBS B-E=-16/470, A-E=0/397, C-E=-100/456
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Bearing at joint(s) F, D considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity
of bearing surface.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 94 lb uplift at joint F and 94 lb uplift at joint
D.
7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BRETT JENSEN - HEGSTED
Truss
M01
Truss Type
Roof Special
Qty
4
Ply
1
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:46:13 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-622?kFGvE_pOzJhzHD?3WjGFvwWQaODgTjR76pzQzre
Scale = 1:63.1
T1
T2
W2
B1
W1 W2
W3
W5
W4
A
B
C D
G F EH I J
2x4
1.5x4
3x6 3x4
3x4
4x8
4x6
9-8-0
9-8-0
14-9-8
5-1-8
4-10-0
4-10-0
9-8-0
4-10-0
14-9-8
5-1-8
4-6-1111-0-08.00 12
Plate Offsets (X,Y)-- [C:0-6-4,0-2-4]
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.78
0.57
0.33
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.35
-0.51
0.01
0.01
(loc)
F-G
F-G
E
F
l/defl
>491
>339
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 115 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W5: 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt D-E, B-F, C-E, B-G
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) E=725/Mechanical, G=725/0-5-8 (min. 0-1-8)
Max HorzG=260(LC 8)
Max UpliftE=-236(LC 8), G=-24(LC 8)
Max GravE=763(LC 2), G=778(LC 15)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-424/58
BOT CHORD G-H=-239/378, H-I=-239/378, F-I=-239/378, F-J=-99/290, E-J=-99/290
WEBS B-F=-168/251, C-F=-127/500, C-E=-682/233, B-G=-565/0
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.5psf.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 236 lb uplift at joint E and 24 lb uplift at joint
G.
8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BRETT JENSEN - HEGSTED
Truss
N01
Truss Type
Roof Special
Qty
6
Ply
1
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:46:15 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-2RAl9xI9lb35CcrLPe1Xb8MhojCn2MTzx1wEAhzQzrc
Scale: 3/16"=1'
T1
T2
W4
B1
W2
W3
W1
A
B C
E D
F G
1.5x4
5x6
1.5x4
3x4 3x4
2-2-8
2-2-8
7-4-0
5-1-8
2-2-8
2-2-8
7-4-0
5-1-8
9-6-511-0-08.00 12
Plate Offsets (X,Y)-- [B:0-3-12,0-2-0]
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.44
0.51
0.09
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.23
-0.33
-0.00
0.00
(loc)
D-E
D-E
D
E
l/defl
>367
>259
n/a
****
L/d
360
240
n/a
240
PLATES
MT20
Weight: 77 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BRACING-
TOP CHORD Sheathed or 7-4-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt C-D, B-D, A-E, B-E
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) D=352/Mechanical, E=352/0-5-8 (min. 0-1-8)
Max HorzE=57(LC 8)
Max UpliftD=-125(LC 5), E=-13(LC 4)
Max GravD=370(LC 2), E=378(LC 2)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.5psf.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 125 lb uplift at joint D and 13 lb uplift at joint
E.
8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
BRETT JENSEN - HEGSTED
Truss
PB01
Truss Type
Piggyback
Qty
1
Ply
1
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:46:17 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-_qIVacJQHDJpRw_kW33?gZR63X?0WHhGOLPLFazQzra
Scale = 1:17.5
T1
T2
T1
B1
ST1
A
B
C
D E
F
G
H
3x4 3x4
2x4 2x4 1.5x4
1.5x4
9-0-0
9-0-0
2-6-12
2-6-12
6-5-4
3-10-8
9-0-0
2-6-12
0-4-71-6-91-8-80-1-80-4-70-1-81-5-18.00 12
Plate Offsets (X,Y)-- [C:0-2-0,Edge], [E:0-2-0,Edge]
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.07
0.08
0.04
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.00
-0.00
0.00
(loc)
G
G
F
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 25 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) B=271/7-6-2 (min. 0-1-8), F=271/7-6-2 (min. 0-1-8), H=291/7-6-2 (min. 0-1-8)
Max HorzB=-38(LC 6)
Max UpliftB=-65(LC 8), F=-65(LC 9), H=-42(LC 5)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-281/66, E-F=-281/64
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
3) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs
non-concurrent with other live loads.
4) Provide adequate drainage to prevent water ponding.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 65 lb uplift at joint B, 65 lb uplift at joint F and
42 lb uplift at joint H.
9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
LOAD CASE(S) Standard
Job
BRETT JENSEN - HEGSTED
Truss
PB02
Truss Type
Piggyback
Qty
4
Ply
1
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:46:19 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-xCQG?ILgpqZXhE86eU6TmzWQvLgX_B?YrfuRKTzQzrY
Scale = 1:19.2
T1 T1
B1
ST1
A
B
C
D
E
F
4x4
2x4 2x4 1.5x4
9-0-0
9-0-0
4-6-0
4-6-0
9-0-0
4-6-0
0-4-73-0-00-1-80-4-70-1-88.00 12
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.24
0.08
0.05
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.01
-0.00
0.00
(loc)
E
E
D
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 28 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) B=256/7-6-2 (min. 0-1-8), D=256/7-6-2 (min. 0-1-8), F=321/7-6-2 (min. 0-1-8)
Max HorzB=-74(LC 6)
Max UpliftB=-69(LC 8), D=-78(LC 9), F=-21(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS C-F=-250/60
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
3) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs
non-concurrent with other live loads.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 69 lb uplift at joint B, 78 lb uplift at joint D
and 21 lb uplift at joint F.
8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
9) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
LOAD CASE(S) Standard
Job
BRETT JENSEN - HEGSTED
Truss
PB03
Truss Type
Piggyback
Qty
10
Ply
1
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:46:21 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-tbX0P_MwLRqFwXIVlv8xrOcmP8M8S5krJzNYOLzQzrW
Scale = 1:19.1
T1
T2
W1
B1
ST1
A
B
C D
F E
4x4
1.5x4
1.5x4 2x4
1.5x4
5-1-8
5-1-8
4-6-0
4-6-0
5-1-8
0-7-8
0-4-73-0-00-1-82-5-80-1-88.00 12
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.24
0.07
0.04
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.00
0.00
0.00
(loc)
A
A
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 20 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 5-1-8 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) E=-25/4-4-9 (min. 0-1-8), B=225/4-4-9 (min. 0-1-8), F=264/4-4-9 (min. 0-1-8)
Max HorzB=106(LC 8)
Max UpliftE=-102(LC 3), B=-32(LC 8), F=-42(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
3) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs
non-concurrent with other live loads.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 102 lb uplift at joint E, 32 lb uplift at joint B
and 42 lb uplift at joint F.
8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
9) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
LOAD CASE(S) Standard
Job
BRETT JENSEN - HEGSTED
Truss
PB04
Truss Type
Piggyback
Qty
1
Ply
2
Brett Jensen - Hegsted
Job Reference (optional)
8.420 s Nov 10 2020 MiTek Industries, Inc. Thu Apr 14 11:46:22 2022 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:pHiyN4G3Bw3V4kjqRe_u0IzRDxy-Ln5OdKNY6ly6YhthJcfANc8y_YjpBYB?Yd66wozQzrV
Scale = 1:19.2
T1 T1
B1
ST1
A
B
C
D
E
F
4x4
2x4 2x4 1.5x4
9-0-0
9-0-0
4-6-0
4-6-0
9-0-0
4-6-0
0-4-73-0-00-1-80-4-70-1-88.00 12
LOADING (psf)
TCLL
(Roof Snow=35.0)
TCDL
BCLL
BCDL
35.0
7.5
0.0 *
7.5
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2018/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.12
0.04
0.03
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.00
-0.00
0.00
(loc)
E
E
D
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 56 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size) B=256/7-6-2 (min. 0-1-8), D=256/7-6-2 (min. 0-1-8), F=321/7-6-2 (min. 0-1-8)
Max HorzB=-74(LC 6)
Max UpliftB=-69(LC 8), D=-78(LC 9), F=-21(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS C-F=-250/60
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc.
Bottom chords connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
4) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9; Cs=1.00; Ct=1.00
5) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs
non-concurrent with other live loads.
6) Gable requires continuous bottom chord bearing.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 69 lb uplift at joint B, 78 lb uplift at joint D
and 21 lb uplift at joint F.
10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
LOAD CASE(S) Standard