Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED PLANS - 22-00076 - 367 Talon Dr - Solar Panels
Author Name Author Email Author Phone No.: Larry Beesley Larry.Beesley@rexburg.org 208-372-2176 Alex Owens Alex.Owens@rexburg.org 208-372-2330 Description : 367 Talon Dr - Solar Panels Address : 367 Talon Dr Record Type : Solar Panels Document Filename : MAROON PERMIT PACKET + SS.pdf Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Approved # 22-00076 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments PV-1 Stamp Larry Beesley : Building Open 1 Approved - Building Inspector PV-2 Free text Larry Beesley : Building Open 2 The pathway at the ridge must be 36" because you are covering more than 33% of that section of roof as per the code R 324.6.2 PV-2 Line Larry Beesley : Building Open 2 PV-2 Line Larry Beesley : Building Open 2 PV-2 Free text Larry Beesley : Building Open 2 36" PV-2 Free text Larry Beesley : Building Open 2 36" PV-2 Stamp Larry Beesley : Building Open 2 Corrections Required Pg 12 Stamp Larry Beesley : Building Open 12 Approved - Building Inspector Pg 13 Stamp Larry Beesley : Building Open 13 Approved - Building Inspector Pg 14 Stamp Larry Beesley : Building Open 14 Approved - Building Inspector Pg 15 Stamp Larry Beesley : Building Open 15 Approved - Building Inspector PV-1 Stamp Alex Owens : Electrical Open 1 Approved - Electrical Inspector Solar Panels Approval of plans does not constitute approval of variance from code Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments PV-3 Stamp Alex Owens : Electrical Open 3 Approved - Electrical Inspector PV-4 Stamp Alex Owens : Electrical Open 4 Approved - Electrical Inspector Pg 5 Stamp Alex Owens : Electrical Open 5 Approved - Electrical Inspector Pg 6 Stamp Alex Owens : Electrical Open 6 Approved - Electrical Inspector Pg 7 Stamp Alex Owens : Electrical Open 7 Approved - Electrical Inspector Pg 8 Stamp Alex Owens : Electrical Open 8 Approved - Electrical Inspector Pg 9 Stamp Alex Owens : Electrical Open 9 Approved - Electrical Inspector Pg 10 Stamp Alex Owens : Electrical Open 10 Approved - Electrical Inspector Pg 11 Stamp Alex Owens : Electrical Open 11 Approved - Electrical Inspector Approval of plans does not constitute approval of variance from code Powered by TCPDF (www.tcpdf.org) ADDITIONAL NOTES P L A N S E T L E G E N D S H E E T I N D E X V I C I N I T Y M A P A P P L I C A B L E C O D E S A B B R E V I A T I O N S P R O J E C T I N F O R M A T I O N 1.ALL MODULES WILL BE GROUNDED IN ACCORDANCE WITHTHE CODE AND THE MANUFACTURES INSTALLATIONINSTRUCTIONS.2. ALL PLACARDS REQUIRED BY NEC 2017 CODE MACHINEPRINTED LETTERS IN A CONTRASTING COLOR TO THEPLACARD.3. LIQUID TIGHT FLEXIBLE CONDUIT SHALL BE SUNLIGHTRESISTANT.4. ELECTRICAL INSTALLATION WILL COMPLY WITH NEC 2017CODE.5. ALL SOLAR MODULES EQUIPMENT AND METALLICCOMPONENTS ARE TO BE BONDED.6. ALL PLUMBING AND MECHANICAL ROOF VENTS TO CLEARFROM PHOTOVOLTAIC ARRAY, OR EXTEND ABOVE SOLARPANELS.7. SOLAR PHOTOVOLTAIC SYSTEM TO BE INSTALLED ONRESIDENTIAL STRUCTURE.8. DESIGN COMPLYING WITH THE IBC 2018 CODE AND ALLLOCAL ORDINANCES AND POLICIES.9. THE PROJECT HAS BEEN DESIGNED TO WITHSTAND AMINIMUM 110 MPH WIND LOAD.10. THE SYSTEM WILL NOT BE INTERCONNECTED UNTILAPPROVAL FROM THE LOCAL JURISDICTION AND A UTILITYIS OBTAINED.11. IF THE MAIN SERVICE PANEL DOES NOT HAVE VERIFIABLEGROUNDING ELECTRODE, IT IS THE CONTRACTORSRESPONSIBILITY TO INSTALL SUPPLEMENTAL GROUNDINGELECTRODE.12. EACH MODULE WILL BE GROUNDED USING THE SUPPLIEDCONNECTION POINTS IDENTIFIED ON THE MODULE ANDTHE MANUFACTURERS INSTALLATION INSTRUCTIONS.13. A LADDER SHALL BE IN PLACE FOR INSPECTION INCOMPLIANCE WITH OSHA REGULATIONS.14. PROPER ACCESS AND WORKING CLEARANCE WILL BEPROVIDED "WARNING: PV POWER SOURCE" TO BE PLACEDEVERY 10 FT.15. GFCI PROTECTION IN INVERTER.OCCUPANCY: R-3CONSTRUCTION TYPE: V-BUNSPRINKLERED ALL CONDUIT TO RUN ON EXTERIOR OF HOUSE UNLESSOTHERWISE NOTED P V - 1 P R O J E C T I N F O R M A T I O N , V I C I N I T Y M A P P V - 2 S I T E P L A N , A E R I A L V I E W P V - 3 E L E C T R I C A L L I N E D I A G R A M A N D N O T E S P V - 4 R E Q U I R E D S I G N A G E A L L W O R K T O C O M P L Y W I T H T H E F O L L O W I N G C O D E : N E C 2 0 1 7 C O D E I B C / I R C / I F C 2 0 1 8 C O D E PROJECT INFORMATION, VICINITY MAP ISSUED FOR: PERMIT DATE 02/03/2022 SCALE: NTS JOB #:www.bigdogenergy.com SOLAR PHOTOVOLTAIC SYSTEM MATTHEW MAROON DESIGNED BY CONTRACTOR INFORMATION P V - 1 367, TALON DR, REXBURG,, ID 83440 BIG DOG RENEWABLE ENERGY CONTRACTOR LIC #: IDAHO #017916 620 PHEASANT RIDGE DR CHUBBUCK, ID 83202 208-242-3352 T 208-232-5935 F X__________________ ( E ) E X I S T I N G ( N ) N E W E X T E X T E R I O R I N T I N T E R I O R E M T E L E C T R I C A L M E T A L L I C T U B I N G R M T R I G I D M E T A L L I C T U B I N G F M C F L E X I B L E M E T A L L I C C O N D U I T V O C V O L T A G E O P E N C I R C U I T V M P V O L T A G E A T M A X . P O W E R I S C S H O R T C I R C U I T C U R R E N T I M P C U R R E N T A T M A X . P O W E R N T S N O T T O S C A L E 2 1 - Q . P E A K D U O B L K M L - G 1 0 + 4 0 0 ( 4 0 0 W ) P H O T O V O L T A I C M O D U L E S 1 - S O L A R E D G E S E 7 6 0 0 H - U S W I T H P R I S M T E C H N O L O G Y ( 7 6 0 0 W ) I N V E R T E R S Y S T E M S I Z E : 8 . 4 0 0 K W D C S T C A R R A Y A R E A : 4 4 3 . 8 5 S F MSPSUBACDCSLCMINVJBCBBAT M A I N S E R V I C E P A N E L S U B P A N E L A C D I S C O N N E C T D C D I S C O N N E C T S O L A R L O A D C E N T E R M O N I T O R I N G M E T E R I N V E R T E R J U N C T I O N B O X C O M B I N E R B O X B A T T E R Y P V P R O D U C T I O N M E T E R R A P I D H U T D O W N D I S C O N N E C T PMRSD M A T T H E W M A R O O N 3 6 7 T A L O N D R , R E X B U R G , , I D 8 3 4 4 0 2/4/2022 MSP AC MTR INV S C A L E : N T S T O T A L # O F P A N E L S : 2 1 R O O F T Y P E : S H I N G L E S A E R I A L V I E W S C A L E : N T S SITE PLAN, AERIAL VIEW N ISSUED FOR: PERMIT DATE 02/03/2022 SCALE: NTS JOB #:www.bigdogenergy.com SOLAR PHOTOVOLTAIC SYSTEM MATTHEW MAROON DESIGNED BY CONTRACTOR INFORMATION P V - 2 367, TALON DR, REXBURG,, ID 83440 BIG DOG RENEWABLE ENERGY CONTRACTOR LIC #: IDAHO #017916 620 PHEASANT RIDGE DR CHUBBUCK, ID 83202 208-242-3352 T 208-232-5935 F X__________________ SITE PLAN A B B R E V I A T I O N S I N V I N V E R T E R M S P M A I N S E R V I C E P A N E L A C A C D I S C O N N E C T M T R M E T E R TALON DR R O O F D E S C R I P T I O N R O O F A R R A Y P I T C H A Z I M U T H # 1 3 5 ° 1 9 3 ° # 2 3 5 ° 1 9 3 ° 18"CLEARANCE 18"CLEARANCE 1 8 " C L E A R A N C E 1 8 " C L E A R A N C E 1 8 " C L E A R A N C E 18"CLEARANCE 18"CLEARANCE18"CLEARANCE 1 8 " C L E A R A N C E R O O F # 1 ROOF #2 A C D I S C O N N E C T W I T H I N 3 ’ F R O M U T I L I T Y M E T E R 18" CLEARANCE2/4/2022 The pathway at the ridge must be 36" because you are covering more than 33% of that section of roof as per the code R 324.6.2 3 6 " 36" ELECTRICAL SINGLE LINE DIAGRAM 1 . P V A R R A Y S A R E P E R S I N G L E L I N E . 2 . P V A R R A Y W I R I N G T O J U N C T I O N I S # 1 0 A W G U S E 2 W / F I E L D I N S T A L L E D M C C O N N E C T O R S T O I N T E R F A C E W / M O D U L E S . 3 . P V A R R A Y C O M B I N E R / J U N C T I O N B O X P R O V I D E S T R A N S I T I O N F R O M A R R A Y W I R I N G T O C O N D U I T W I R I N G . 4 . U S E U F E R G R O U N D E L E C T R O D E S Y S T E M F R O M I N V E R T E R T O E X I S T I N G M A I N S E R V I C E G R O U N D E L E C T R O D E P E R N . E . C . 2 5 0 . 5 8 . 5 . G R O U N D E L E C T R O D E C O N D U C T O R F R O M I N V E R T E R T O G R O U N D E L E C T R O D E T O B E M I N I M U M P R O T E C T I O N O F B A R E A R M O R S H E A T H E D C A B L E F O R A L L C O N D U C T O R S I Z E S . 6 . A L L G R O U N D C O N N E C T E D T O M A I N S E R V I C E G R O U N D I N M A I N S E R V I C E P A N E L . 7 . C O N N E C T O R S S H A L L B E P O L A R I S O R E U R O S T R I P I T C O N N E C T O R S . 8 . I N V E R T E R S H A L L B E P E R S I N G L E L I N E , S E E A T T A C H E D C U T S H E E T . 9 . I N V E R T E R I S P E R S I N G L E L I N E . 1 0 . A C D I S C O N N E C T S H A L L B E P E R S I N G L E L I N E . 1 1 . E Q U I P M E N T G R O U N D I N G C O N D U C T O R S O N A C A N D D C S I D E S I Z E D A C C O R D I N G T O N . E . C . 6 9 0 . 1 2 . P O L E O F P V A R R A Y R E F E R E N C E D T O G R O U N D A T T H E I N V E R T E R I N S I N G L E L I N E . 1 3 . A L L C O N D U C T O R S S H A L L B E 6 0 0 V , 9 0 C S T A N D A R D C O P P E R . A L L C O N D U C T O R S I N C O N D U I T S H A L L B E T H W N - 2 . 1 4 . M A X I M U M D C V O L T A G E D R O P S H A L L B E 2 . 5 % 1 5 . A L L C O N D U C T O R S S H A L L B E I N C O N D U I T U N L E S S O T H E R W I S E N O T E D . 1 6 . A L L W O R K T O C O M P L Y W I T H N E C 2 0 1 7 C O D E . 1 7 . D C A R R A Y C O N D U C T O R S A R E T O R E M A I N O U T S I D E O F B U I L D I N G P R I O R T O F U S I B L E C O M B I N E R B O X O R F U S I B L E D C D I S C O N N E C T M E A N S . 1 8 . E X A C T C O N D U I T R U N L O C A T I O N S S U B J E C T T O C H A N G E . 1 9 . 3 . 0 P S F M A X ( . 5 P S F F R O M R A C K I N G , 2 . 5 P S F F R O M M O D U L E S ) D E A D L O A D C O N T R I B U T E D F R O M S O L A R A R R A Y . 2 0 . A R C F A U L T I N S T A L L E D A T I N V E R T E R O R I N C O M B I N E R B O X . 2 1 . D C G R O U N D F A U L T P R O T E C T I O N I N T E G R A T E D I N I N V E R T E R . 2 2 . P O I N T O F C O N N E C T I O N B R E A K E R T O B E L O C A T E D O P P O S I T E E N D O F B U S B A R F R O M M A I N U N L E S S O T H E R W I S E N O T E D . 2 3 . A N Y U N D E R G R O U N D W I R I N G M E T H O D S W I L L C O M P L Y W I T H N E C 3 0 0 . 5 ( J ) , 3 0 0 . 7 ( B ) , 3 5 2 . 4 4 , A N D O T H E R S E C T I O N S O F C H A P T E R 3 A S A P P L I C A B L E . 2 4 . A N Y E X P O S E D P V C C O N D U I T S H A L L C O M P L Y W I T H N E C 3 5 2 . 1 0 2 5 . A L L P V S Y S T E M D C C I R C U I T S R U N I N S I D E A B U I L D I N G S H A L L B E C O N T A I N E D I N A M E T A L R A C E W A Y I N A C C O R D A N C E T O N E C 6 9 0 . 3 1 ( G ) 2 6 . C O M P L I E S W I T H 7 0 5 . 1 2 ( B ) ( 2 ) ( 3 ) ( B ) 2 7 . S U P P L Y S I D E C O N N E C T I O N W I T H L I S T E D I N S U L A T I O N P I E R C I N G C O N N E C T O R S I N A C C O R D A N C E W I T H 7 0 5 . 1 2 ( A ) A N D 2 3 0 . 8 2 2 8 . C O N N E C T I O N A T P A N E L S E C O N D A R Y S E R V I C E L O C A T I O N 2 9 . C O M P L I E S W I T H 7 0 5 . 1 2 ( B ) ( 2 ) ( 1 ) ( B ) E L E C T R I C A L N O T E S S C A L E : N T S SINGLE LINE DIAGRAM R A C K I N G & M O D U L E S A R E G R O U N D E D V I A A C O N T I N U O U S # 6 A W G C O P P E R C O N D U C T O R C O N N E C T E D W / W E E B S - M O D U L E S A R E F A C T O R Y P R O V I D E D W / 2 T H R E A D E D H O L E S T O F A C I L I T A T E L A N D I N G O F T H E L U G S A L L E Q U I P M E N T S H A L L B E P R O P E R L Y G R O U N D E D A N D B O N D E D I N A C C O R D A N C E W I T H A R T I C L E 2 5 0 . A L L C I R C U I T S C O N N E C T E D T O M O R E T H A N O N E S O U R C E S H A L L H A V E O V E R C U R R E N T D E V I C E S L O C A T E D S O A S T O P R O V I D E O V E R C U R R E N T P R O T E C T I O N F R O M A L L S O U R C E S 6 9 0 . 9 ( A ) ISSUED FOR: PERMIT DATE 02/03/2022 SCALE: NTS JOB #:www.bigdogenergy.com SOLAR PHOTOVOLTAIC SYSTEM MATTHEW MAROON DESIGNED BY CONTRACTOR INFORMATION P V - 3 367, TALON DR, REXBURG,, ID 83440 BIG DOG RENEWABLE ENERGY CONTRACTOR LIC #: IDAHO #017916 620 PHEASANT RIDGE DR CHUBBUCK, ID 83202 208-242-3352 T 208-232-5935 F X__________________ A L L M O D U L E S W I L L B E G R O U N D E D I N A C C O R D A N C E W I T H C O D E A N D T H E M A N U F A C T U R E R ' S I N S T A L L A T I O N I N S T R U C T I O N S . M O D U L E : Q . P E A K D U O B L K M L - G 1 0 + 4 0 0 ( 4 0 0 W ) V o c = 4 5 . 3 0 V I s c = 1 1 . 1 4 A V m p = 3 7 . 1 3 V I m p = 1 0 . 7 7 A ELECTRICAL E Q U I P M E N T C A L L O U T S 8,400W TOTAL SOLAR ARRAY21 Q.PEAK DUO BLK ML-G10+ 400 (400W) PANELSWIRE AND CONDUIT CALLOUTS SOLADECK M O D E L 0 7 8 3 - 4 1 J U N C T I O N BOX/ROOF P E N E T R A T I O N , 6 0 0 V 7.6kW INVER T E R U N G R O U N D E D SOLAREDG E S E 7 6 0 0 H - U S W I T H P R I S M TECHNOLO G Y ( 2 4 0 V ) I N V E R T E R 240VAC, 32A , N E M A 3 R , U L L I S T E D , (W/ INTEGR A T E D D C D I S C O N N E C T ) WITH INTEG R A T E D G F P , W / I N T E G R A T E D A F P (2) #10 AWG PV/RHW-2 IN FREE AIR(1) #6 AWG BARE COPPER GND IN FREE AIR(2) #10 AWG THWN-2(1) #10 AWG THWN-2 GND IN 3/4" EMT/FMC(2) #8 AWG THWN-2(1) #10 AWG THWN-2 GND IN 3/4" EMT SOLAREDGE P 4 0 1 O P T I M I Z E R O N E P E R P A N E L BI-DIRECTIO N A L U T I L I T Y M E T E R ABCDEF1 STRING OF 11 MODULES1 STRING OF 10 MODULES CONNECTED IN SERIES @ INVERTERSQUARE D S A F E T Y S W I T C H , # H 2 2 2 N R B 250 VAC, 60 A , N E M A 3 R , F U S E D , U L , N E M A , CSA, NOM C E R T I F I E D W / 4 0 A F U S E S 1231ELECTRICAL LINE DIAGRAMPV-3SCALE: NTS 4(2) #8 AWG THWN-2(1) #10 AWG THWN-2 GND IN 3/4" EMT 200A (E) MAI N S E R V I C E P A N E L (W/ 200A MA I N B R E A K E R T O P F E D ) L1L2NG DL1L2NG440AE BACKFEED 26NG200A F B A T T E R Y D C I N P U T _~ M P P T 1 M P P T 2 3 C 1 0 M O D U L E S I N S E R I E S 1 1 M O D U L E S I N S E R I E S B A A B O N E P E R P A N E L 2 1 S T R I N G 1 S T R I N G 2 O N E P E R P A N E L 2 1 N O B A T T E R Y B A C K U P T O B E I N C L U D E D W I T H T H I S P E R M I T AC DISCONNECTWITHIN 3’ FROM UTILITY METER REQUIRED SIGNAGE ISSUED FOR: PERMIT DATE 02/03/2022 SCALE: NTS JOB #:www.bigdogenergy.com SOLAR PHOTOVOLTAIC SYSTEM MATTHEW MAROON DESIGNED BY CONTRACTOR INFORMATION P V - 4 367, TALON DR, REXBURG,, ID 83440 BIG DOG RENEWABLE ENERGY CONTRACTOR LIC #: IDAHO #017916 620 PHEASANT RIDGE DR CHUBBUCK, ID 83202 208-242-3352 T 208-232-5935 F X__________________ REQUIRED SIGNAGE 2. LABEL FOR SOLAR AC DISCONNECT: S Y S T E M A C V O L T A G E : 2 4 0 V T O T A L R A T E D A C A M P S : 4 0 A S Y S T E M A C V O L T A G E : 2 4 0 V 3. THE FOLLOWING SIGNAGE MUST HAVE A MINIMUM OF 3/8"HIGH LETTERING, IN ARIAL FONT (NON-BOLD), WITH CAPITALLETTERS, WHITE ON RED BACKGROUND AND A REFLECTIVE,WEATHER RESISTANT MATERIAL.1. PROVIDE A PLACARD WITH THE FOLLOWING WORKING IN 1/4"HIGH LETTERING PER NEC 690-17.AT THE MAIN SERVICE DISCONNECT PROVIDE A SIGN WITH THEFOLLOWING WORDING: FOLLOWING WORDING:THE SIGN SHOULD BE PLACED ON THE OUTSIDE COVER IF THE MAINSERVICE DISCONNECT IS OPERABLE WITH THE SERVICE PANEL CLOSED.CUSTOMER OWNEDON SITE POWER GENERATIONSYSTEM DISCONNECT D I R E C T C U R R E N T P H O T O V O L T A I C S O U R C E S Y S T E M A C V O L T A G E : 2 4 0 V M A X A C C I R C U I T C U R R E N T : 3 2 A M A X D C C U R R E N T P E R O P T I M I Z E R : 1 5 A 8. T H E F O L L O W I N G S I G N M U S T B E P R O V I D E D O N T H E O U T S I D E ( O R W I T H I N 3 ' O F ) T H E S E R V I C E P A N E L B O A R D , A S R E Q U I R E D P E R N E C 6 9 0 . 5 6 ( C ) ( 1 ) : R A P I D S H U T D O W N S W I T C H F O R S O L A R P V S Y S T E M P H O T O V O L T A I C S Y S T E M E Q U I P P E D W I T H R A P I D S H U T D O W N A L L S I G N A G E M U S T B E P E R M A N E N T L Y A T T A C H E D A N D B E W E A T H E R R E S I S T A N T / S U N L I G H T R E S I S T A N T A N D C A N N O T B E H A N D - W R I T T E N . N E C 1 1 0 . 2 1 ( B ) FIRE DEPARTMENT REQUIRED SIGNAGE4. LABELS TO BE INSTALLED ON FACE OF THE UTILITY AC DISCONNECT:5. LABEL INSTALLATION AT INTERCONNECT BREAKER:10 . S I G N A G E R E Q U I R E D A T S T R I N G I N V E R T E R P E R N E C 6 9 0 . 5 3 : 9. S I G N A G E R E Q U I R E D A T S E R V I C E P A N E L B O A R D P E R N E C 6 9 0 . 5 4 : 7. A T P V D I S C O N N E C T S W I T C H A S R E Q U I R E D P E R N E C 6 9 0 . 5 6 ( C ) ( 3 ) : 6. R E F L E C T I V E P L A C A R D A T S E R V I C E S T A T I N G : "SOLAR AC DISCONNECT"WARNING:ELECTRICAL SHOCK HAZARD.DO NOT TOUCH TERMINALS. TERMINALSON BOTH THE LINE AND LOAD SIDES MAYBE ENERGIZED IN THE OPEN POSITION.WARNING:INVERTER CONNECTION.DO NOT RELOCATE THISOVERCURRENT DEVICE.WARNINGDUAL POWER SUPPLYSOURCES: UTILITY GRID ANDPV SOLAR ELECTRIC SYSTEM Single Phase Energy Hub Inverter with Prism Technology For North America SE3000H-US / SE3800H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US(1) 12-25 YEAR WARRANTY Optimized battery storage with HD-Wave technology Record-breaking 99% weighted efficiency with 200% DC oversizing Small, lightweight, and easy to install Modular design, future ready with optional upgrades to: DC-coupled storage for full or partial home backup Built-in consumption monitoring Direct connection to the SolarEdge smart EVcharger Multi-inverter, scalable storage solution With enhanced battery power up to 10kW Integrated arc fault protection and rapid shutdown for NEC 2014,NEC 2017 and NEC 2020,per article 690.11 and 690.12 Embedded revenue grade production data, ANSI C12.20 Class 0.5 solaredge.com H O M E B A C K U P Single Phase Energy Hub Inverter with Prism Technology For North America SE3000H-US / SE3800H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US(1) SE3000H-US SE3800H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US UNITS OUTPUT - AC ON GRID Rated AC Power 3000 3800 @ 240V 3300 @ 208V 6000 @ 240V 5000 @ 208V 7600 10000 11400 @ 240V 10000 @ 208V W Maximum AC Power Output 3000 3800 @ 240V 3300 @ 208V 6000 @ 240V 5000 @ 208V 7600 10000 11400 @ 240V 10000 @ 208V W AC Frequency Range (min - nom - max) 59.3 - 60 - 60.5(2)Hz Maximum Continuous Output Current @ 240V 12.5 16 25 32 42 47.5 A Maximum Continuous Output Current @ 208V - 16 24 - - 48.5 A GFDI Threshold 1 A Total Harmonic Distortion (THD) <3 % Power Factor 1, adjustable -0.85 to 0.85 Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes Charge Battery from AC (if allowed) Yes Typical Nighttime Power Consumption <2.5 W OUTPUT - AC BACKUP(3) Rated AC Power in Backup Operation(4) 3000 3800 6000 7600 10000 10300 W 7600* 10300* AC L-L Output Voltage Range in Backup 211 - 264 Vac AC L-N Output Voltage Range in Backup 105 - 132 Vac AC Frequency Range in Backup (min - nom - max) 55 - 60 - 65 Hz Maximum Continuous Output Current in Backup Operation 12.5 16 25 32 42 43 A 32* 43* GFDI 1 A THD <5 % OUTPUT - SMART EV CHARGER AC Rated AC Power 9600 W AC Output Voltage Range 211 - 264 Vac On-Grid AC Frequency Range (min - nom - max) 59.3 - 60 - 60.5 Hz Maximum Continuous Output Current @240V (grid, PV and battery) 40 Aac INPUT - DC (PV AND BATTERY) Transformer-less, Ungrounded Yes Max Input Voltage 480 Vdc Nom DC Input Voltage 380 Vdc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600kΩ Sensitivity INPUT - DC (PV) Maximum DC Power @ 240V 6000 7600 12000 15200 22000 22800 W 15200* 22800* Maximum DC Power @ 208V - 6600 10000 - - 20000 W Maximum Input Current(5) @ 240V 8.5 10.5 16.5 20 27 31 Adc 20* 31* Maximum Input Current(5) @ 208V - 9 13.5 - - 27 Adc Max. Input Short Circuit Current 45 Adc Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 99 @ 240V 98.5 @ 208V % 2-pole Disconnection Yes *Supported with PN SExxxxH-USMMxxxxxx or SExxxxH-USMNxxxxxx (1) These specifications apply to inverters with part numbers SExxxxH-USSMxxxxx or SExxxxH-USSNxxxxxx and connection unit model number DCD-1PH-US-PxH-F-x (2) For other regional settings please contact SolarEdge support (3) Not designed for standalone applications and requires AC for commissioning. Backup functionality is only supported for 240V grid(4) Rated AC power in Backup Operation are valid for installations with multiple inverters. For a single backup inverter operation, rated AC power in Backup is 90% of the value stated (5) A higher current source may be used; the inverter will limit its input current to the values stated Single Phase Energy Hub Inverter with Prism Technology For North America SE3000H-US / SE3800H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US(1) SE3000H-US SE3800H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US UNITS INPUT - DC (BATTERY) Supported Battery Types SolarEdge Energy Bank, LG RESU Prime(6) Number of Batteries per Inverter Up to 3 SolarEdge Energy Bank, up to 2 LG RESU Prime Continuous Power(7) 6000 7600 10000 W Peak Power(7) 6000 7600 10000 W Max Input Current 16 20 26.5 Adc 2-pole Disconnection Yes SMART ENERGY CAPABILITIES Consumption Metering Built - in(8) Backup & Battery Storage With Backup Interface (purchased separately) for service up to 200A; Up to 3 inverters EV Charging Direct connection to Smart EV charger ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, Cellular(9), Wi-Fi (optional),SolarEdge Energy Net (optional) Revenue Grade Metering, ANSI C12.20 Built - in(8) Integrated AC, DC and Communication Connection Unit Yes Inverter Commissioning With the SetApp mobile application using built-in Wi-Fi Access Point for local connection DC Voltage Rapid Shutdown (PV and Battery) Yes, according to NEC 2014, NEC 2017 and NEC 2020 690.12 STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1741 PCS, UL1699B, UL1998, UL9540, CSA 22.2 Grid Connection Standards IEEE1547, Rule 21, Rule 14H Emissions FCC part 15 class B INSTALLATION SPECIFICATIONS AC Output and EV AC Output Conduit Size / AWG Range 1'' maximum / 14-4 AWG DC Input (PV and Battery) Conduit Size / AWG Range 1'' maximum / 14-6 AWG Dimensions with Connection Unit (H x W x D) 17.7 x 14.6 x 6.8 / 450 x 370 x 174 17.7 x 14.6 x 6.8 / 450 x 370 x 174 17.7 x 14.6 x 6.8 / 450 x 370 x 174 in / mm 17.7 x 14.6 x 6.8 / 450 x 370 x 174* Weight with Connection Unit 26 / 11.8 26 / 11.8 30.2 / 13.7 lb / kg 30.2 / 13.7* Noise < 25 < 25 < 25 < 50 dBA < 50* Cooling Natural Convection Operating Temperature Range -40 to +140 / -40 to +60(10) ˚F / ˚C Protection Rating NEMA 4 (6)The part numbers SExxxxH-USxMxxxxx only support the SolarEdge Energy Bank. The part numbers SExxxxH-USxNxxxxx support both SolarEdge Energy Bank and LG RESU Prime batteries Requires supporting inverter firmware(7)Discharge power is limited up to the inverter rated AC power for on-grid and backup applications (8)For consumption metering current transformers should be ordered separately: SECT-SPL-225A-T-20 or SEACT0750-400NA-20 units per box. Revenue grade metering is only for production metering (9)Information concerning the Data Plan's terms & conditions is available in the following link: https://www.solaredge.com/sites/default/files/se-communication-plan-terms-and-conditions-eng.pdf (10)Full power up to at least 50°C / 122°F; for power de-rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners.Date:06/2021 DS-000031-1.5-NAM.Subject to change without notice. Power Optimizer For North America P320 / P340 / P370 / P400 / P401 / P405 / P485 / P505 25 YEAR WARRANTY PV power optimization at the module-level Specifically designed to work with SolarEdge inverters Up to 25% more energy Superior efficiency (99.5%) Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading Flexible system design for maximum space utilization Fast installation with a single bolt Next generation maintenance with module- level monitoring Meets NEC requirements for arc fault protection (AFCI) and Photovoltaic Rapid Shutdown System (PVRSS) Module-level voltage shutdown for installer and firefighter safety solaredge.com P O W E R O P T I M I Z E R Power Optimizer For North America P320 / P340 / P370 / P400 / P401 / P405 / P485 / P505 Optimizer model (typical module compatibility) P320 (for 60-cell modules) P340 (for high- power 60-cellmodules) P370 (for higher- power 60 and 72- cell modules) P400 (for 72 & 96-cellmodules) P401 (for high power 60 and 72 cell modules) P405 (for high- voltage modules) P485 (for high- voltage modules) P505 (for higher current modules) INPUT Rated Input DC Power(1) 320 350 370 400 485 505 W Absolute Maximum Input Voltage (Voc at lowest temperature) 48 60 80 60 125(2) 83(2) Vdc MPPT Operating Range 8 - 48 8 - 60 8 - 80 8-60 12.5 - 105 12.5 - 83 Vdc Maximum Short Circuit Current (Isc) 11 11.02 11 10.1 11.75 11 14 Adc Maximum DC Input Current 13.75 12.5 14.65 12.5 17.5 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 98.6 % Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power Optimizer 1 ± 0.1 Vdc STANDARD COMPLIANCE EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741 Material UL94 V-0, UV Resistant RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions (W x L x H) 129 x 153 x 27.5 / 5.1 x 6 x 1.1 129 x 153 x 33.5 / 5.1 x 6 x 1.3 129 x 153 x 29.5 / 5.1 x 6 x 1.16 129 x 159 x 49.5 / 5.1 x 6.3 x 1.9 129 x 162 x 59 / 5.1 x 6.4 x 2.3 mm / in Weight (including cables) 630 / 1.4 750 / 1.7 655 / 1.5 845 / 1.9 1064 / 2.3 gr / lb Input Connector MC4(3) Single or dual MC4(3)(4) MC4(3) Input Wire Length 0.16 / 0.52 0.16 or 0.9 /0.52 or 2.95(5) 0.16 / 0.52 m / ft Output Wire Type / Connector Double Insulated / MC4 Output Wire Length 0.9 / 2.95 1.2 / 3.9 m / ft Operating Temperature Range(6) -40 to +85 / -40 to +185 ˚C / ˚F Protection Rating IP68 / NEMA6P Relative Humidity 0 - 100 % (1)Rated power of the module at STC will not exceed the optimizer “Rated Input DC Power ”. Modules with up to +5% power tolerance are allowed (2)NEC 2017 requires max input voltage be not more than 80V (3)For other connector types please contact SolarEdge (4)For dual version for parallel connection of two modules use P485-4NMDMRM. In the case of an odd number of PV modules in one string, installing one P485 dual version power optimizer connected to one PV module. When connecting a single module seal the unused input connectors with the supplied pair of seals(5)Longer inputs wire length are available for use. For 0.9m input wire length order P401-xxxLxxx(6)For ambient temperature above +85°C / +185°F power de-rating is applied. Refer to Power Optimizers Temperature De-Rating Technical Note for more details PV System Design Using a SolarEdge Inverter(7)(8) Single Phase HD-Wave Single phase Three Phase for 208V grid Three Phase for 277/480V grid Minimum String Length (Power Optimizers) P320, P340, P370, P400, P401 8 10 18 P405, P485, P505 6 8 14 Maximum String Length (Power Optimizers) 25 25 50(9) Maximum Power per String 5700 (6000 with SE7600-US - SE11400- US) 5250 6000(10) 12750(11) W Parallel Strings of Different Lengths or Orientations Yes (7) For detailed string sizing information refer to: http://www.solaredge.com/sites/default/files/string_sizing_na.pdf (8) It is not allowed to mix P405/P485/P505 with P320/P340/P370/P400/P401 in one string (9) A string with more than 30 optimizers does not meet NEC rapid shutdown requirements; safety voltage will be above the 30V requirement (10) For 208V grid: it is allowed to install up to 6,500W per string when the maximum power difference between each string is 1,000W (11) For 277/480V grid: it is allowed to install up to 15,000W per string when the maximum power difference between each string is 2,000W © SolarEdge Technologies Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 08/2021 DS-000044-1.2-NA. Subject to change without notice. 405 MANUFACTURER SPEC SHEET - RAIL MANUFACTURER SPEC SHEET - RAIL MANUFACTURER SPEC SHEET - RAIL MANUFACTURER SPEC SHEET - RAIL