HomeMy WebLinkAboutCONCRETE FIELD TESTS - 21-00586 - Just4Kids Pediatric Urgent CareFile Name: 21056FB10112021EV PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. FFBF2D49-DB26-4CC7-9A47-6CA010FA1C56 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 21056 Cumulative Test Load Amount: 11.0 Project Name: Just For Kids Test Location: Footings Client: Bateman-Hall Admixtures: Ticket Number: 4622 Contractor: JM Construction Supplier: Walters Ready Mix Mix Number: 1700 JFKU Pour Date: 10/4/2021 Cylinder Log #: 621 Field Test Results: Set #: 1 Slump (inches): 3.0 Slump Maximum (in): Entrained Air (%): 5.25 Entrained Air Spec. (%): Concrete Temperature (°F): 58 Ambient Temperature (°F): 75 Unit Weight (PCF): 142.97 Tested By: E. Vail Date: 10/4/2021 Time Tested: 1:15 PM Picked Up By: E. Vail Date: 10/4/2021 Time: 3:15 PM Max, Min Temperature N/A Initial Break Results: Cylinder #: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Break Type: Required 28 day Strength (psi): A 7 10/11/2021 4.00 12.56 45,410.0 3615.45 Type 1 4,000.0 Date: 10/12/2021 Reviewed By: E. Vail Signature: File Name: 21056FB10182021EV PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 73127BC1-2777-45BF-9CE4-23B1F8321D28 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 21056 Cumulative Test Load Amount: 11.0 Project Name: Just For Kids Test Location: Foundation walls Client: Bateman Hall Admixtures: MP 322, MA AE 90 Ticket Number: 4756 Contractor: JM Concrete Supplier: Walters Ready Mix Mix Number: 142 JFKUC Pour Date: 10/11/2021 Cylinder Log #: 633 Field Test Results: Set #: 1 Slump (inches): 4.0 Slump Maximum (in): Entrained Air (%): 4.80 Entrained Air Spec. (%): Concrete Temperature (°F): 61 Ambient Temperature (°F): 39 Unit Weight (PCF): 141.45 Tested By: E. Vail Date: 10/11/2021 Time Tested: 1:00 PM Picked Up By: E. Vail Date: 10/12/2021 Time: 2:30 PM Max, Min Temperature 87.9, 48 Initial Break Results: Cylinder #: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Break Type: Required 28 day Strength (psi): A 7 10/18/2021 4.00 12.56 53,245.0 4239.25 Type 2 3,000.0 Date: 10/18/2021 Reviewed By: E. Vail Signature: File name: 21056SB11012021EV PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 9AC00F5B-792F-41E8-808A-4FD5F9D84697 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 21056 Cumulative Test Load Amount: 11.0 Project Name: Just For Kids Test Location: Footings Client: Bateman-Hall Admixtures: Ticket Number: 4622 Contractor: JM Construction Supplier: Walters Ready Mix Mix Number: 1700 JFKU Date: 10/4/2021 Cylinder Log #: 621 Field Test Results: Set #: 1 Slump (inches): 3.0 Slump Maximum (in): Entrained Air (%): 5.25 Entrained Air Spec. (%): Concrete Temperature (°F): 58 Ambient Temperature (°F): 75 Unit Weight (PCF): 142.97 Tested By: E. Vail Date: 10/4/2021 Picked Up By: E. Vail Date: 10/5/2021 Time: 3:15 PM Max, Min Temperature N/A Previous Test Results: Cylinder ID: Break Age:Break Date: Diameter (in): Area (in^2: Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 10/11/2021 12.56 45410 3615.45 4,000.00 Type 1 File name: 21056SB11012021EV PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 9AC00F5B-792F-41E8-808A-4FD5F9D84697 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 11/1/2021 4.00 12.6 60,575.0 4807.5 4,000.0 Type 2 C 28 11/1/2021 4.00 12.6 58,720.0 4660.3 4,000.0 Type 2 D 28 11/1/2021 4.00 12.6 56,455.0 4480.6 4,000.0 Type 2 Second Break Average: 4649 Date: 11/01/2021 Reviewed By: E. Vail Signature: File name: 21056SB11082021EV CD6FCB10-953A-496D-970B-4B8D30B6A445 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 21056 Cumulative Test Load Amount: 11.0 Project Name: Just For Kids Test Location: Foundation walls Client: Bateman Hall Admixtures: MP 322, MA AE 90 Ticket Number: 4756 Contractor: JM Concrete Supplier: Walters Ready Mix Mix Number: 142 JFKUC Date: 10/11/2021 Cylinder Log #: 633 Field Test Results: Set #: 1 Slump (inches): 4.0 Slump Maximum (in): Entrained Air (%): 4.80 Entrained Air Spec. (%): Concrete Temperature (°F): 61 Ambient Temperature (°F): 39 Unit Weight (PCF): 141.45 Tested By: E. Vail Date: 10/11/2021 Picked Up By: E. Vail Date: 10/12/2021 Time: 2:30 PM Max, Min Temperature 87.9, 48 Previous Test Results: Cylinder ID: Break Age:Break Date: Diameter (in): Area (in^2: Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 10/18/2021 4.00 12.56 53245 4239.25 3,000.00 Type 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 11/8/2021 4.00 12.6 73,215.0 5810.7 3,000.0 Type 2 C 28 11/8/2021 4.00 12.6 71,355.0 5663.1 3,000.0 Type 2 D 28 11/8/2021 4.00 12.6 68,180.0 5411.1 3,000.0 Type 2 Second Break Average: 5628 Date: 11/08/2021 Reviewed By: E. Vail Signature: File Name 21056C10042021EV PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive/ confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 1DFCB3A1-A7CA-44BA-832E-132E8630EEAA 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 21056 Cumulative Test Load Amount: 11.0 Project Name: Just For Kids Test Location: Footings Client: Bateman-Hall Admixtures: Required 28 day Strength (psi): 4,000.0 Contractor: JM Construction Supplier: Walters Ready Mix Mix Number: 1700 JFKU Ticket #: 04622 Date: 10/04/2021 Testing: Set #:Time Tested: Ticket #:Test Location: Ambient Temp. (°F): Unit Weight (PCF): Entrained Air (%): Entrained Air Spec. (%): Concrete Temp. (°F): Slump (in): Slump Spec. (in): 1 01:15 PM 04622 Footings 75 142.97 5.25 4 to 8 58 3.00 Max 4 Remarks: Tested By: E. Vail Signature: Date: 10/04/2021 Reviewed By: E. Vail Signature: Date: 10/05/2021 File Name 21056C10112021EV PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive/ confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 337387B3-22CA-4930-8B33-7F0623CD7B49 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 21056 Cumulative Test Load Amount: 11.0 Project Name: Just For Kids Test Location: Foundation walls Client: Bateman Hall Admixtures: MP 322, MA AE 90 Required 28 day Strength (psi): 3,000.0 Contractor: JM Concrete Supplier: Walters Ready Mix Mix Number: 142 JFKUC Ticket #: 04756 Date: 10/11/2021 Testing: Set #:Time Tested: Ticket #:Test Location: Ambient Temp. (°F): Unit Weight (PCF): Entrained Air (%): Entrained Air Spec. (%): Concrete Temp. (°F): Slump (in): Slump Spec. (in): 1 01:00 PM 04756 Foundation walls 39 141.45 4.80 4 to 8 61 4.00 Max 4 Remarks: Tested By: E. Vail Signature: Date: 10/11/2021 Reviewed By: E. Vail Signature: Date: 10/11/2021 File Name: 21056FB11152021EV 093F14F7-B377-4D5F-9421-812C67E3014A 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 21056 Cumulative Test Load Amount: 55.0 Project Name: Just For Kids Test Location: 1.6, E.5 Client: Bateman Hall Admixtures: CMT, MS AC 534, MP 322 Ticket Number: 5281 Contractor: Bateman Hall Supplier: Walters Ready Mix Mix Number: 142I JFKU Pour Date: 11/8/2021 Cylinder Log #: 708 Field Test Results: Set #: 2 Slump (inches): 6.0 Slump Maximum (in): Entrained Air (%): 1.40 Entrained Air Spec. (%): Concrete Temperature (°F): 67 Ambient Temperature (°F): 42 Unit Weight (PCF): 146.75 Tested By: G. Stastny Date: 11/8/2021 Time Tested: 10:00 AM Picked Up By: E. Vail Date: 11/9/2021 Time: 10:45 AM Max, Min Temperature N/A File Name: 21056FB11152021EV 093F14F7-B377-4D5F-9421-812C67E3014A 2 Initial Break Results: Cylinder #: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Break Type: Required 28 day Strength (psi): A 7 11/15/2021 4.00 12.56 68,845.0 5481.29 Type 2 4,000.0 Date: 11/17/2021 Reviewed By: E. Vail Signature: File Name: 21056FB11152021EV D584C0A6-468D-4A16-8C08-40231F6FD047 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 21056 Cumulative Test Load Amount: 11.0 Project Name: Just For Kids Test Location: 1.6, E.5 Client: Bateman Hall Admixtures: CMT, MS AC 534, MP 322 Ticket Number: 5276 Contractor: Bateman Hall Supplier: Walters Ready Mix Mix Number: 142I JFKU Pour Date: 11/8/2021 Cylinder Log #: 707 Field Test Results: Set #: 1 Slump (inches): 4.0 Slump Maximum (in): Entrained Air (%): 1.50 Entrained Air Spec. (%): Concrete Temperature (°F): 69 Ambient Temperature (°F): 25 Unit Weight (PCF): 146.99 Tested By: G. Stastny Date: 11/8/2021 Time Tested: 8:15 AM Picked Up By: E. Vail Date: 11/9/2021 Time: 10:30 AM Max, Min Temperature N/A File Name: 21056FB11152021EV D584C0A6-468D-4A16-8C08-40231F6FD047 2 Initial Break Results: Cylinder #: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Break Type: Required 28 day Strength (psi): A 7 11/15/2021 4.00 12.56 76,725.0 6108.68 Type 2 4,000.0 Date: 11/17/2021 Reviewed By: E. Vail Signature: File Name: 21056FB11162021EV A77E549C-9684-414F-A3FC-9AD163D35780 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 21056 Cumulative Test Load Amount: 3.0 Project Name: Just For Kids Test Location: Trash pad foundation walls. Client: Bateman Hall Admixtures: MP 322, MA AE 90 Ticket Number: 5319 Contractor: JM Concrete Supplier: Walters Mix Number: 142 JFKUC Pour Date: 11/9/2021 Cylinder Log #: 710 Field Test Results: Set #: 1 Slump (inches): 4.0 Slump Maximum (in): Entrained Air (%): 4.00 Entrained Air Spec. (%): Concrete Temperature (°F): 55 Ambient Temperature (°F): 40 Unit Weight (PCF): 138.63 Tested By: E. Vail Date: 11/9/2021 Time Tested: 2:30 PM Picked Up By: Date: Time: Max, Min Temperature File Name: 21056FB11162021EV A77E549C-9684-414F-A3FC-9AD163D35780 2 Initial Break Results: Cylinder #: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Break Type: Required 28 day Strength (psi): A 7 11/16/2021 4.00 12.56 55,475.0 4416.80 Type 2 3,000.0 Date: 11/17/2021 Reviewed By: E. Vail Signature: File name: 21056SB12062021EV PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive/ confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 831C441A-AE50-4AEC-ACA0-997725BDF9B4 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 21056 Cumulative Test Load Amount: 11.0 Project Name: Just For Kids Test Location: 1.6, E.5 Client: Bateman Hall Admixtures: CMT, MS AC 534, MP 322 Ticket Number: 5276 Contractor: Bateman Hall Supplier: Walters Ready Mix Mix Number: 142I JFKU Date: 11/8/2021 Cylinder Log #: 707 Field Test Results: Set #: 1 Slump (inches): 4.0 Slump Maximum (in): Entrained Air (%): 1.50 Entrained Air Spec. (%): Concrete Temperature (°F): 69 Ambient Temperature (°F): 25 Unit Weight (PCF): 146.99 Tested By: G. Stastny Date: 11/8/2021 Picked Up By: E. Vail Date: 11/9/2021 Time: 10:30 AM Max, Min Temperature N/A Previous Test Results: Cylinder ID: Break Age:Break Date: Diameter (in): Area (in^2: Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 11/15/2021 12.56 76725 6108.68 4,000.00 Type 2 File name: 21056SB12062021EV PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive/ confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 831C441A-AE50-4AEC-ACA0-997725BDF9B4 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 12/6/2021 4.00 12.6 88,590.0 7031.0 4,000.0 Type 1 C 28 12/6/2021 4.00 12.6 88,195.0 6999.6 4,000.0 Type 2 D 28 12/6/2021 4.00 12.6 90,960.0 7219.0 4,000.0 Type 1 Second Break Average: 7083 Date: 12/06/2021 Reviewed By: E. Vail Signature: File name: 21056SB12062021EV2 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive/ confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. D14F37CE-B303-4FC5-AE1E-D7465A6A394F 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 21056 Cumulative Test Load Amount: 55.0 Project Name: Just For Kids Test Location: 1.6, E.5 Client: Bateman Hall Admixtures: CMT, MS AC 534, MP 322 Ticket Number: 5281 Contractor: Bateman Hall Supplier: Walters Ready Mix Mix Number: 142I JFKU Date: 11/8/2021 Cylinder Log #: 708 Field Test Results: Set #: 2 Slump (inches): 6.0 Slump Maximum (in): Entrained Air (%): 1.40 Entrained Air Spec. (%): Concrete Temperature (°F): 67 Ambient Temperature (°F): 42 Unit Weight (PCF): 146.75 Tested By: G. Stastny Date: 11/8/2021 Picked Up By: E. Vail Date: 11/9/2021 Time: 10:45 AM Max, Min Temperature N/A Previous Test Results: Cylinder ID: Break Age:Break Date: Diameter (in): Area (in^2: Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 11/15/2021 12.56 68845 5481.29 4,000.00 Type 2 File name: 21056SB12062021EV2 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive/ confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. D14F37CE-B303-4FC5-AE1E-D7465A6A394F 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 12/6/2021 4.00 12.6 79,895.0 6340.9 4,000.0 Type 3 C 28 12/6/2021 4.00 12.6 79,375.0 6299.6 4,000.0 Type 2 D 28 12/6/2021 4.00 12.6 81,615.0 6477.4 4,000.0 Type 2 Second Break Average: 6372 Date: 12/06/2021 Reviewed By: E. Vail Signature: File name: 21056SB12072021EV PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive/ confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. DB87715E-D7BE-418C-8B46-5F59C325D3AA 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 21056 Cumulative Test Load Amount: 3.0 Project Name: Just For Kids Test Location: Trash pad foundation walls. Client: Bateman Hall Admixtures: MP 322, MA AE 90 Ticket Number: 5319 Contractor: JM Concrete Supplier: Walters Mix Number: 142 JFKUC Date: 11/9/2021 Cylinder Log #: 710 Field Test Results: Set #: 1 Slump (inches): 4.0 Slump Maximum (in): Entrained Air (%): 4.00 Entrained Air Spec. (%): Concrete Temperature (°F): 55 Ambient Temperature (°F): 40 Unit Weight (PCF): 138.63 Tested By: E. Vail Date: 11/9/2021 Picked Up By: E. Vail Date: 11/10/2021 Time: 10:00 AM Max, Min Temperature 87, 39.3 Previous Test Results: Cylinder ID: Break Age:Break Date: Diameter (in): Area (in^2: Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 11/16/2021 12.56 55475 4416.80 3,000.00 Type 2 File name: 21056SB12072021EV PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive/ confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. DB87715E-D7BE-418C-8B46-5F59C325D3AA 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 12/7/2021 4.00 12.6 75,500.0 5992.1 3,000.0 Type 1 C 28 12/7/2021 4.00 12.6 73,845.0 5860.7 3,000.0 Type 3 D 28 12/7/2021 4.00 12.6 74,800.0 5936.5 3,000.0 Type 1 Second Break Average: 5929 Date: 12/07/2021 Reviewed By: E. Vail Signature: File Name 21056C11082021GKS 11a5fe16b57ffdca-1636386450701 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 21056 Cumulative Test Load Amount: 11.0 Project Name: Just For Kids Test Location: 1.6, E.5 Client: Bateman Hall Admixtures: CMT, MS AC 534, MP 322 Required 28 day Strength (psi): 4,000.0 Contractor: Bateman Hall Supplier: Walters Ready Mix Mix Number: 142I JFKU Ticket #: 05276 Date: 11/08/2021 Testing: Set #:Time Tested: Ticket #:Test Location: Ambient Temp. (°F): Unit Weight (PCF): Entrained Air (%): Entrained Air Spec. (%): Concrete Temp. (°F): Slump (in): Slump Spec. (in): 1 08:15 AM 05276 1.6, E.5 25 146.99 1.50 4 to 8 69 4.00 Max 4 2 10:00 AM 05281 1.6, E.5 42 146.75 1.40 4 to 8 67 6.00 Max 4 Remarks: Tested By: Gabe Stastny Signature: Date: 11/08/2021 Reviewed By: E. Vail Signature: Date: 11/09/2021 File Name 21056C11092021EV AD079E41-9B8A-469D-8EC2-EDF2424E52FF 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 21056 Cumulative Test Load Amount: 3.0 Project Name: Just For Kids Test Location: Trash pad foundation walls. Client: Bateman Hall Admixtures: MP 322, MA AE 90 Required 28 day Strength (psi): 3,000.0 Contractor: JM Concrete Supplier: Walters Mix Number: 142 JFKUC Ticket #: 05319 Date: 11/09/2021 Testing: Set #:Time Tested: Ticket #:Test Location: Ambient Temp. (°F): Unit Weight (PCF): Entrained Air (%): Entrained Air Spec. (%): Concrete Temp. (°F): Slump (in): Slump Spec. (in): 1 02:30 PM 05319 Trash pad foundation walls. 40 138.63 4.00 4 to 8 55 4.00 Max 4 Remarks: Tested By: E. Vail Signature: Date: 11/09/2021 Reviewed By: E. Vail Signature: Date: 11/09/2021 File Name: 21056CPU11092021EV A7ADC0C8-E325-44FC-B01F-77E3FFEAC956 1 4103 E. 605 N. Sute. 1 Rigby ID, 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 21056 Required 28 day Strength (psi): 4,000.0 Project Name: Just For Kids Supplier: Walters Ready Mix Client: Bateman-Hall Mix Number: 142I JFKU Contractor: Bateman Hall Pour Date: 11/8/2021 Cylinder Log In: Cylinder ID:Set #:Concrete Log #: Ticket Number: Break Age: Break Date:Diameter Area in^2 A 2 708 5281 7 11/15/2021 4.00 12.56 B 2 708 5281 28 12/06/2021 4.00 12.56 C 2 708 5281 28 12/06/2021 4.00 12.56 D 2 708 5281 28 12/06/2021 4.00 12.56 E 2 708 5281 28 12/06/2021 4.00 12.56 Remarks: Time: 10:45 AM Max, Min Temperature N/A Picked Up By: E. Vail Signature: Date: 11/09/2021 Reviewed By: E. Vail Signature: Date: 11/09/2021 File Name: 21056CPU11092021EV 5DA5BC94-274E-41EF-B482-3B99C6D65C62 1 4103 E. 605 N. Sute. 1 Rigby ID, 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 21056 Required 28 day Strength (psi): 4,000.0 Project Name: Just For Kids Supplier: Walters Ready Mix Client: Bateman-Hall Mix Number: 142I JFKU Contractor: Bateman Hall Pour Date: 11/8/2021 Cylinder Log In: Cylinder ID:Set #:Concrete Log #: Ticket Number: Break Age: Break Date:Diameter Area in^2 A 1 707 5276 7 11/15/2021 4.00 12.56 B 1 707 5276 28 12/06/2021 4.00 12.56 C 1 707 5276 28 12/06/2021 4.00 12.56 D 1 707 5276 28 12/06/2021 4.00 12.56 E 1 707 5276 28 12/06/2021 4.00 12.56 Remarks: Time: 10:30 AM Max, Min Temperature N/A Picked Up By: E. Vail Signature: Date: 11/09/2021 Reviewed By: E. Vail Signature: Date: 11/09/2021 File Name: 21056FB05112022LC PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. AEB69017-B8AE-482B-9057-1F565DB65B81 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 21056 Cumulative Test Load Amount: 9.0 Project Name: Just For Kids Test Location: Collected at NW curb corner. Tested on N side of building. Client: Bateman Hall Admixtures: MP 322, MA AE 90 Ticket Number: 7528 Contractor: Bateman Hall Supplier: Walters Ready Mix Mix Number: 526AF JFK Pour Date: 5/4/2022 Cylinder Log #: 172 Field Test Results: Set #: 1 Slump (inches): 1.8 Slump Maximum (in): Entrained Air (%): 4.00 Entrained Air Spec. (%): Concrete Temperature (°F): 56 Ambient Temperature (°F): 36 Unit Weight (PCF): 141.29 Tested By: A. Walburger Date: 5/4/2022 Time Tested: 12:30 PM Picked Up By: Luke Hammar Date: 5/5/2022 Time: 11:15 AM Max, Min Temperature 80,60 Initial Break Results: Cylinder #: Break Age: Break Date: Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Break Type: Required 28 day Strength (psi): A 7 5/11/2022 12.56 56,760.0 4519.11 Type 4 4,000.0 Date: 05/11/2022 Reviewed By: E. Vail Signature: File Name 21056C05042022AW PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. F8452E9C-CC86-4140-88F8-93022A4526DE 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 21056 Cumulative Test Load Amount: 9.0 Ticket #: 07528 Project Name: Just For Kids Test Location: Collected at NW curb corner. Tested on N side of building. Client: Bateman Hall Admixtures: MP 322, MA AE 90 Required 28 day Strength (psi): 4,000.0 Contractor: Bateman Hall Supplier: Walters Ready Mix Mix Number: 526AF JFK Date: 05/04/2022 Start Time 07:00 AM End Time 10:45 AM Testing: Set #:Time Tested: Ticket #:Test Location: Ambient Temp. (°F): Unit Weight (PCF): Entrained Air (%): Entrained Air Spec. (%): Concrete Temp. (°F): Slump (in): Slump Spec. (in): 1 08:45 AM 07528 Collected at NW curb corner. Tested on N side of building. 36 141.29 4.00 4 to 8 56 1.75 Max 4 Observations/Remarks: I arrived at the lab at 6:45 AM. I got the vehicle keys and verified the concrete’s specifications before leaving the lab at 7:00 AM. When I arrived on site, I checked where to set up my equipment with the PM, Sam. The concrete arrived at 8:30 AM, and I collected and tested a sample at 8:45 AM, after about a yard had been placed. The air content and slump were within specifications. I then made cylinders and cleaned the tested equipment. The cylinders were left in a red cooler on the N side of the building. File Name 21056C05042022AW PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. F8452E9C-CC86-4140-88F8-93022A4526DE 2 I left the sight at 10:00 AM, and finished unloading the equipment and reporting the results at 10:45 AM. Tested By: AWalburger Signature: Reviewed By: E. Vail Signature: Date: 05/04/2022 Inspection Images File Name 21056C05042022AW PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. F8452E9C-CC86-4140-88F8-93022A4526DE 3 File Name 21056C05042022AW PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. F8452E9C-CC86-4140-88F8-93022A4526DE 4