HomeMy WebLinkAboutPLAN REVIEW RESPONSE - 21-00586 - Just4Kids Pediatric Urgent Care  12 Sunnen Dr. Suite 100      St. Louis, MO 63143      314.821.1100            The CASCO Diversified Corporation Companies  August 18, 2021  Via:  Electronic Delivery    Cody Jones – Building Official  Community Development Department  City of Rexburg  35 North 1st East  Rexburg, ID 83440    (208) 372‐2173  Email:  Cody.Jones@rexburg.org    Re:  Just4Kids Pediatric Urgent Care    1218 Bond Avenue   Rexburg, ID    Plans – 21‐00586     Dear Cody,     The following plan review responses are hereby submitted to address your comments dated  8/10/2021.    Comment: Is this building considered an ambulatory health facility?  If so, it would need to meet  the  requirements  of section 422.  Services offered do  not render  patients  incapable  of  self‐ preservation.    Response: The clinic does not meet the definition for an Ambulatory Care Facility per section 422  and  is classified as a Business Occupancy per section 304.1 Professional Services (architects,  attorneys, dentists, physicians, engineer, etc.).  Services offered do not render patients incapable  of self‐preservation, and patients are provided care on less than a 24‐hour basis, with no overnight  stays.    Comment:  Rear lot line within 5’, allows 10% in exterior wall openings.    Response: The exterior wall openings on the rear wall are 8.85%; below the allowed 10% threshold.    Comment: Need COMM check.    Response:  ComCheck  energy  calculations  were  intended  to  be  uploaded  with  the  plan  set.   ComCheck is now hereby provided.    Comment:  Draft stopping in attic shall subdivide combustible attic space so that no horizontal area  exceeds 3,000 square feet per section 718.4.      12 Sunnen Dr. Suite 100      St. Louis, MO 63143      314.821.1100            The CASCO Diversified Corporation Companies  Response: The location of the draft stopping has been indicated on the A2.0 sheet.    Comment: Suspended ceiling to be installed to manufacturer’s specifications.    Response: Understood, a note stating such has been added to the ceiling plan A2.0.    Comment:  Concealed spaces need to be fire blocked/draft stopped per section 718.    Response: Revised detail 7/A8.1.    Comment:  Special inspector to be identified.    Response:  Owner is in the process of hiring the Special Inspection agency and the information will  be supplied to the City upon receipt from the Owner.    Comment:  Roof and roof fire classification?    Response: The roof classification has been added to the A1.2 sheet.    Comment: Signs to be posted.    Response:  A note has been added to the floor plan A1.0 indicating the General Contractor shall  provide a maximum occupancy sign within the Lobby area indicating the building occupancy of 32.    Warm Regards,        Steve Dahms – Senior Project Manager    cc:  Brandon Lee – Just4Kids    Doil Clements, Austin Gutierrez – Bateman‐Hall  BJV/File