HomeMy WebLinkAboutREVIEW RESPONSE - 21-00725 - Iron Horse RV - Interior FinishC I TY OF REXBURG OW America's Family Community Community Development Department 35 North 111 East Rexburg,ID 83440 Permit Technician (208) 372-2166 Inspection Hotline (208) 372-2344 Description : Iron Horse RV - Interior Finish Address: 1076 S 12th W Application Type: Document Filename: 03 Iron Horse Architectural 090921.pdf Array Comment Author Contact Information: Author Name Author Email Author Phone NO.: Stan Crittenden Stan.Crittenden@rexburg.org 208-372-2314 Kyle Baldwin Kyle.Baldwin@rexburg.org 208-372-2164 Cody Jones Cody.Jones@rexburg.org 208-372-2173 Corrections in the following table need to be applied before a permit can be issued Panic Hardware shall be installed as per IBC Section 1010.1.10 Review Report Revisions Required # 21-00725 Commercial - Remodel Page Reference Annotation Author: Department Status Page Review Comments Applicant Response Comments Type G0.1 Free text Cody Jones : Building Open 1 as per city ordinance, buildings connot be partially sprinkled 903.3.9.1 in the code analysis now states that even if only some areas require sprinklers and others do not. "full building to be fire sprinklered". G0.1 Free text Cody Jones : Building Open 1 seating at tables, counters and work areas comply with section Note 1109.11 stating a min. o or seating ... shall be accessible" has been added to the 1109.11 code analysis G0.1 Free text Cody Jones : Building Open 1 Special inspector needs to be identified. Atlas Technical Consultants has been added tc the project consultant list on the cover sheet. G0.1 Free text Cody Jones : Building Open 1 Need Envelope COMM check. See attached. G0.1 Free text Cody Jones : Building Open 1 Restrooms, rooms, occupant load and other directional Note 10.04 on sheet A1.1 has been modified signage to be installed. to include the listed signage needs. A1.1 Free text Cody Jones : Building Open 2 Exit lighting and exit signs to comply with sections 1008 and These IBC references were added to the 1013. Code Analysis on the cover sheet. A4.1 Free text Cody Jones : Building Open 8 Grade to slope away from building 6" in first 10'. Note 31.01 on sheet A4.1 has been modified. A4.1 Free text Cody Jones : Building Open 8 36" min Req'd dims have been added on sheet A4.1 A5.1 Comment Cody Jones : Building Open 9 Handrails and Guards meet the requirements of IBC Sections General reference note 01.01 has been 1014 and 1015 modified to reference the IBC sections noted. Approval of plans does not constitute approval of variance from code Report Date: 10.06.2021 Pagel of 2 Page Reference Annotation Author: Department Status Page Review Comments Applicant Response Comments Type A5.1 Free text Cody Jones : Building Open 9 Minimum of one restroom to be ADA accessible.(with 60" Restroom 108 is now shown with 60" ADA turning radius.) compliant turning radius. A6.1 Comment Cody Jones : Building Open 11 Panic Hardware shall be installed as per IBC Section 1010.1.10 IBC Section 1010.1.10 does not require the us of panic hardware in this project. No change made. A6.1 Free text CodYJones Building Open 11 Glass and glazing to meet requirements of Chapter 24. A6.2 Free text Cody Jones : Building Open 12 Suspended ceiling to be installed to manufacturer specifications. This note has been added to window types A6 G0.1 Free text Stan Crittenden : Fire Open 1 The building will need to have fire sprinklers through out. Noted on cover sheet. G0.1 Free text Stan Crittenden : Fire Open 1 Will need to install a Knox Box for keys at or near the front of Noted on cover sheet. building. This is usually 1-2 months to order. G0.1 Free text Stan Crittenden : Fire Open 1 Will need to verify that the existing fire hydrant on 12th West or the new hydrant on the north end of the developement is Noted on cover sheet. close enough. Approval of plans does not constitute approval of variance from code Report Date: 10.06.2021 Page 2 of 2