Loading...
HomeMy WebLinkAboutINFRASTRUCTURE PLAN Rev. (3) 5.31.22 – 22-00260 Utilities onlySS CO CO CO CO N GRAPHIC SCALE Scale: 1"=10' 30'20'10'5'0' QA / Q C DE S I G N E D DR A W N AP P R O V E D NO . RE V I S I O N S DA T E BY Th i s d o c u m e n t o r a n y p a r t t h e r e o f i n d e t a i l o r d e s i g n co n c e p t i s t h e p r o p e r t y o f F o r s g r e n A s s o c i a t e s I n c . a n d sh a l l n o t b e c o p i e d w i t h o u t t h e w r i t t e n a u t h o r i z a t i o n o f Fo r s g r e n A s s o c i a t e s I n c . PAGE NO: DATE: SHEET NO: (IF NOT 2"- SCALE ACCORDINGLY) AT FULL SIZE LINE IS 2 INCHES ATTENTION PR O J E C T N O . 3 5 0 N O R T H 2 N D E A S T , R E X B U R G , I D 8 3 4 4 0 PH : 2 0 8 . 3 5 6 . 9 2 0 1 F A X : 2 0 8 .3 5 6 .0 2 0 6 CONSTRUCTION NOTES JA M E S HI R R L I N G E R 7T H N O R T H A P P A R T M E N T S 14 2 0 9 A.ALL DIMENSIONS AND COORDINATES ARE TO BACK OF CURB UNLESS NOTED OTHERWISE. B.ALL UTILITY LINES ARE TO BE LOCATED AS SHOWN ON THE PLANS UNLESS RELOCATED IN THE FIELD BY THE ENGINEER TO AVOID UNFORESEEN UTILITY INTERFERENCE. C.PROVIDE TRENCHING FOR ALL LINES PER ISPWC SD-301. D.INSTALL THRUST BLOCKS AT ALL BENDS IN PRESSURE LINES PER ISPWC SD-402. E.THERE SHALL BE A 10' MINIMUM HORIZONTAL SEPARATION DISTANCE BETWEEN ALL EXISTING WATER LINES AND NEW SEWER LINES EXCEPT WHERE WATER AND SEWER LINES CROSS AT APPROXIMATELY RIGHT ANGLES WHERE A MINIMUM OF 1.5 FEET OF VERTICAL SEPARATION SHALL BE MAINTAINED. F.MINIMUM CLEARANCE BETWEEN NEW PIPELINES AND EXISTING UTILITIES AND STRUCTURES (EXCEPT WATER LINES) SHALL BE TWO FEE HORIZONTALLY. G.MINIMUM DEPTH OF COVER FOR WATER AND SEWER LINES UNLESS OTHERWISE SHOWN ON PLANS SHALL BE FIVE (5) FEET. H.CONTRACTOR SHALL PROVIDE ANY GROUND WATER DEWATERING TO CONSTRUCT THIS PROJECT. KEYED NOTES 1.CONSTRUCT 4" PVC SANITARY SEWER LATERAL PER ISPWC STANDARD DRAWING SD-511 AND SECTION 501 AND 504. 2.INSTALL 8" ASTM D3034 SDR 35 PVC SEWER LINE. 3.CONTRACTOR TO LOCATE AND CONNECT TO EXISTING 8" SEWER STUB. 4.INSTALL CLEAN OUT 5' FROM BUILDING PER ISPWC STANDARD DRAWING SD-506. SIZE TO MATCH PIPE SIZE. LID SHALL BE INSTALLED FLUSH WITH FINISHED GRADE. 5.INSTALL SEWER MANHOLE PER ISPWC STANDARD DRAWING SD-501. 6.CONNECT TO EXISTING WATERLINE WITH 4" HOT TAP WITH 4" GATE VALVE. GATE VALVE TO BE INSTALLED PER ISPWC STANDARD DRAWING SD-406. 7.INSTALL 1" WATER SERVICE AND METER PER CITY OF REXBURG STANDARDS. 8.INSTALL 4" C-900 PVC WATER LINE PER ISPWC SECTION 401 AND ISPWC STANDARD DRAWING SD-301. REPAIR ASPHALT AND GRAVEL SURFACES IN-KIND. 9.INSTALL HYDRANT ASSEMBLY PER ISPWC STANDARD DRAWING SD-404. 6' WIDE SIDEWALK 6' WIDE SIDEWALK P: \ H i r r l i n g e r , J a m e s \ 0 1 - 2 1 - 0 1 5 4 7 t h N o r t h A p a r t m e n t C o m p l e x \ 9 C A D \ S h e e t s \ 0 3 C i v i l \ 0 1 - 2 1 - 0 1 5 4 C 1 0 4 . d w g - -- - - - 5/ 2 7 / 2 0 2 2 8 : 5 3 A M PRELIMINARY 9 OF 9 MAR 2022 C104 UT I L I T I E S P L A N A. S W E N S O N A. S W E N S O N M. P A L M E R 01 - 2 1 - 0 1 5 4 AD D F I R E L I N E S E R V I C E 2 UP D A T E U T I L I T Y D E S I G N 1 5/ 2 2 AE S 5/ 2 2 AE S MANHOLE 1 N: 792305.45 E: 760080.86 RIM 4874.23 IE N 4864.42 IE S 4864.52 IE E 4864.52 MANHOLE 3 N: 792306.73 E: 760226.46 RIM 4874.17 IE W 4865.10 # 11 11 2 3 4 4 4 4 5 5 6 7 7 7 7 8 9 PROPOSED TRANSFORMER LOCATION PROPOSED TRANSFORMER LOCATION BUILDING #1 BUILDING #3 BUILDING #2 BUILDING #4 CA R L O W S T R E E T 7TH NORTH 1 1 1 1 2" FIRE LINE SERVICE 2" FIRE LINE SERVICE 2