Loading...
HomeMy WebLinkAboutREXBURG AG FIRE ALARM - 22-00226 - Valley Ag Warehouse - Fire AlarmRI SLC2•S:021190° RI SLC2•S:024190° RI SLC2•S:023190° RI SLC2•S:016190° RI SLC2•S:017 190° RI SLC2•S:018190° RI SLC2•S:019 190° RI SLC2•S:020 190° RI SLC2•S:011190° RI SLC2•S:012190° RI SLC2•S:013190° RI SLC2•S:014 190° RI SLC2•S:015190° RI SLC2•S:007 190° RI SLC2•S:008190° RI SLC2•S:009 190° RI SLC2•S:010 190° RI SLC2•S:006 190° RI SLC2•S:022 190° C SIG2•001 177CD C SIG2•003 177CD CSIG2•004 177CD C SIG2•005 177CD S SLC2•S:003 FAA LCD SBC1•01,SBP1•01 AOM 1 SLC2•M:001 S SLC2•S:004 WP SIG2•00275CD EOL Re 4.7K ? SIG1 SIG1•00215CDSIG1•00115CD SIG1•003 15CD EOL Re 4.7K ? SIG2 RI SLC2•S:005 190° RI SLC2•S:025 190° FACP RI 190° RI 190° AOM 1SRI 190° EOL Re EOL 4.7K ? RI 190° C WP RI 190° EOL Re EOL 4.7K ? RI 190° RI 190° RI 190° RI 190° S RI 190° FAA LCD RI 190° C RI 190° C P1 RI 190° RI 190° RI 190° RI 190° RI 190° RI 190° C RI 190° Area 0 RI 190° RI 190° 2 SBC1 2 SIG1 2 SLC22 SIG2 2 SBP1 SHEET NUMBER: JOB NUMBER: DATE: 4021Rexburg, ID 83440Fire Alarm SystemRexburg Valley Wide AgHanksville Noyes 03/28/2022 2 of 2 3/10/2022 12:32:51 PM 3/10/2022 12:32:51 PM REVISION 1: DESIGNED BY: REVISION 3: REVISION 2: 04/04/2022 2003 S Hwy 191Teton Smart SecurityIdaho Falls, ID 83401298 1st St208-546-0428N Battery Calculations for Panel: P1 Part No:6700 - FACP ADDRESSABLE 100 POINTS Job number: 1 Job name: Drawing1 Part No.Qty.Description Standby Total Standby Alarm Total Alarm Panel Equipment 5700 B 1 MAIN CARD 200.0000mA 200.0000mA 325.0000mA 325.0000mA Total Panel Stby 200.0000mA Total Panel Alarm 325.0000mA Peripheral Devices EOL-4.7 2 EOL 4.7K (Notification)0.0000mA 0.0000mA 0.0000mA 0.0000mA SWL 2 L-SERIES STROBE, WHITE, WALL (Notification) 15CD 0.0000mA 0.0000mA 43.0000mA 86.0000mA P2WL 1 L-SERIES 2-WIRE, HORN STROBE, WHITE, WALL (Notification) 15CD 83dB 0.0000mA 0.0000mA 44.0000mA 44.0000mA PC2RL 4 L-SERIES 2-WIRE, HORN STROBE, RED, CEILING (Notification) 177CD 89dB 0.0000mA 0.0000mA 254.0000mA 1016.0000mA P2RK 1 HORN/STROBE, 2 WIRE, STANDARD CD, RED, OUTDOOR (Notification) 75CD 76dB 0.0000mA 0.0000mA 154.0000mA 154.0000mA 5860 1 REMOTE LCD ANNUNCIATOR, GRAY (Power)20.0000mA 20.0000mA 20.0000mA 20.0000mA 5860 1 REMOTE LCD ANNUNCIATOR, GRAY (Serial)0.0000mA 0.0000mA 0.0000mA 0.0000mA SK-HEAT-HT 21 HEAT, HIGH TEMP 135F - 190F, ADDRESSABLE (Signaling line)0.2700mA 5.6700mA 0.2700mA 5.6700mA SK-PHOTO 2 SMOKE, PHOTOELECTRIC, ADDRESSABLE (Signaling line)0.2700mA 0.5400mA 0.2700mA 0.5400mA SK-RELAY 1 RELAY MODULE, ADDRESSABLE (Signaling line)0.2600mA 0.2600mA 0.0260mA 0.0260mA Total Peripheral Stby 26.4700mA Total Periph Alarm 1326.2360mA Total Standby Amps 226.4700mA Total Alarm Amps 1651.2360mA Standby time: 24 Hrs 5.435Ah Alarm time: 5 Min 0.138Ah Battery requirement: 5.573Ah Compensation Factors - Standby: 1.2 Alarm: 1.2 Requirement with compensation: 6.687Ah Symbol Legend SYMBOL DESCRIPTION MANUFACTURER PART NUMBER MODEL QUANTITY HEAT, HIGH TEMP 135F - 190F, ADDRESSABLE SILENT KNIGHT SK-HEAT-HT HEAT-HT 42 L-SERIES 2-WIRE, HORN STROBE, RED, CEILING SYSTEM SENSOR PC2RL PC2RL 8 SMOKE, PHOTOELECTRIC, ADDRESSABLE SILENT KNIGHT SK-PHOTO PHOTO 4 REMOTE LCD ANNUNCIATOR, GRAY SILENT KNIGHT 5860 5860 2 RELAY MODULE, ADDRESSABLE SILENT KNIGHT SK-RELAY RELAY 2 HORN/STROBE, 2 WIRE, STANDARD CD, RED, OUTDOOR SYSTEM SENSOR P2RK P2RK 2 EOL 4.7K SILENT KNIGHT EOL-4.7 EOL-4.7 4 L-SERIES STROBE, WHITE, WALL SYSTEM SENSOR SWL SWL 4 L-SERIES 2-WIRE, HORN STROBE, WHITE, WALL SYSTEM SENSOR P2WL P2WL 2 FACP ADDRESSABLE 100 POINTS SILENT KNIGHT 6700 6700 1 RI C S FAA LCD AOM 1 WP EOL Re 4.7K ? FACP Circuit Calculations Panel: P1 Card: 00 Terminal Voltage: 20.4V:DC Amperage: 3.0000A Cable: 14/2 SOL JKT FPLR 1M RL RED #14 Calculations based on Lump Sum Length. Design Criteria: Ambient temperature: 167°F Max. operating voltage drop: 18% Circuit Description Type Total Len SWL, 15CD, 43.000mA P2WL, 15CD, 44.000mA EOL-4.7 Total Amps Gauge V Drop %V Drop Resistance Max Len SIG1 Notification 41'-0 2 1 1 130.0000mA #14 0.16 0.0327V 0.3 Ohms 4600'-0 Circuit Calculations Panel: P1 Card: 00 Terminal Voltage: 20.4V:DC Amperage: 3.0000A Cable: 14/2 SOL JKT FPLR 1M RL RED #14 Calculations based on Lump Sum Length. Design Criteria: Ambient temperature: 167°F Max. operating voltage drop: 18% Circuit Description Type Total Len PC2RL, 177CD, 254.000mA P2RK, 75CD, 154.000mA EOL-4.7 Total Amps Gauge V Drop %V Drop Resistance Max Len SIG2 Notification 354'-0 4 1 1 1170.0000mA #14 12.47 2.5431V 2.2 Ohms 511'-0 Circuit Calculations Panel: P1 Card: 00 Terminal Voltage: 20.4V:DC Amperage: 1.0000A Cable: 14/2 SOL JKT FPLR 1M RL RED #14 Calculations based on Lump Sum Length. Design Criteria: Ambient temperature: 167°F Max. operating voltage drop: 18% Circuit Description Type Total Len 5860, 25.000mA Total Amps Gauge V Drop %V Drop Resistance Max Len SBP1 Power/SBUS RS-485 25'-0 1 20.0000mA #14 0.02 0.0031V 0.2 Ohms 29902'-0 Circuit Calculations Panel: P1 Card: 00 Terminal Voltage: 4.2V:DC Amperage: 1.0000A Cable: 18/2 SOL JKT FPLR 1M RL RED #18 Calculations based on Lump Sum Length. Design Criteria: Ambient temperature: 167°F Max. operating voltage drop: 18% Circuit Description Type Total Len 5860 Total Amps Gauge V Drop %V Drop Resistance Max Len SBC1 Serial/SBUS RS-485 0'-0 1 0.0000mA #18 0.00 0V 0.0 Ohms 0'-0 Circuit Calculations Panel: P1 Card: 00 Terminal Voltage: 20.4V:DC Amperage: 1.0000A Cable: 18/2 SOL JKT FPLR 1M RL RED #18 Calculations based on Lump Sum Length. Design Criteria: Ambient temperature: 167°F Max. operating voltage drop: 18% Circuit Description Type Total Len SK-PHOTO, 0.270mA SK-HEAT-HT, 0.270mA SK-RELAY, 0.260mA Total Amps Gauge V Drop %V Drop Resistance Max Len SLC2 Signaling line/SK - SLC 676'-0 2 21 1 6.4700mA #18 0.33 0.068V 10.5 Ohms 36521'-0 2x 7Ah 12v Batteries In Series 1 Manual Fire Alarm Boxes 1 2 Smoke Detectors 2 3 Heat Detectors 3 4 Fire Alarm AC Power Failure 4 5 Fire Alarm System Low Battery 5 6 Open Circuit 6 7 Ground Fault 7 8 Notification Appliance Circuit Short 8 AActuate Common Alarm Signal IndicatorA BActuate Audible Alarm SignalB CActuate Common Supervisory Signal IndicatorC DActuate Audible Supervisory SignalD E Actuate Common Trouble Signal IndicatorE F Actuate Audible Common Trouble SignalF GActuate Alarm IndicatorG HActuate Evacuation SignalsH I Display/Print Change of StatusI J Transmit Fire Alarm Signal to Supervising StationJ KTransmit Supervisory Signal to Supervising StationK L Transmit Trouble Signal to Supervising StationL Notification SYSTEM INPUTS OPERATIONAL MATRIX SYSTEM OUTPUTS Rexburg Valleywide Ag Fire Alarm System SHEET NUMBER: JOB NUMBER: DATE: 4021 Fire Alarm SystemHanksville Noyes 03/28/2022 1 of 2 3/10/2022 12:32:51 PM 3/10/2022 12:32:51 PM REVISION 1: DESIGNED BY: REVISION 3: REVISION 2: 4/4/2022 Rexburg, ID 834402003 S Hwy 191Rexburg Valley Wide Ag298 1st StTeton Smart SecurityIdaho Falls, ID 83401208-546-0428