HomeMy WebLinkAboutPLANS METER 2 - 22-00339 - Rawlings Ventures - Solar PanelsCOVER SHEETPHOTOVOLTAIC ROOF MOUNT SYSTEM217 N 2ND E, REXBURG, ID 83440 USAREVSHEET NAMESHEET NUMBERDATEDESCRIPTIONVERSIONPV-0 PROJECT NAMEUR05/08/2022INITIAL RELEASEJODY RAWLINGS
217 N 2ND E,
REXBURG, ID 83440 USA
APN# RPRRXB10124331
UTILITY: PACIFICCORP.
AHJ: CITY OF REXBURGSHEET SIZEANSI B11" X 17"HORIZON PWR SC LLC237 N 2ND E SUITE 202 ,REXBURG ID,83440 USACSLB # :RCE-56878TEL: (888) 468-7180Email: permitting@horizonpwr.comSYSTEM SUMMARY:ROOF TYPE: - COMP SHINGLEROOF FRAME: - 2"X4" TRUSSES @ 24" O.C.NUMBER OF LAYERS: - 01STORY: - ONE STORYSNOW LOAD : - 50 PSFWIND SPEED :- 105 MPHWIND EXPOSURE:- BEXPOSURE CATEGORY:- IIDESIGN CRITERIA:PROJECT SITE2VICINITY MAPSCALE: NTSPV-01AERIAL PHOTOSCALE: NTSPV-0ARRAY LOCATIONSPV-0COVER SHEETPV-1SITE PLAN WITH ROOF PLANPV-2ROOF PLAN WITH MODULESPV-3ATTACHMENT DETAILSPV-4 BRANCH LAYOUTPV-5 ELECTRICAL LINE DIAGRAMPV-6 ELECTRICAL CALCULATIONPV-7 PLACARDS & WARNING LABELSPV-8ADDITIONAL NOTESPV-9+EQUIPMENT SPEC SHEETSSHEET INDEX(N) 12 - HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULES(N) 12 - ENPHASE ENERGY IQ7A-72-2-US MICRO-INVERTERS(N) JUNCTION BOX(E) 200A MAIN SERVICE PANEL WITH (E) 200A MAIN BREAKER(N) 30A NON-FUSED AC DISCONNECT(N) PRODUCTION METER(N) ENPHASE IQ COMBINER BOX 312 MODULES-ROOF MOUNTED - 4.80 kWDC, 3.48 kWACGENERAL NOTES·THE CONTRACTOR/INSTALLER OF THE SOLAR PV SYSTEMOVER EXISTING ROOF SHALL CONFORM TO OSHAREQUIREMENTS DURING THE CONSTRUCTION PHASE. JOBSAFETY AND CONSTRUCTION PROCEDURES ARE THE SOLERESPONSIBILITY OF THE CONTRACTOR/INSTALLER.·REFER TO ELECTRICAL DRAWING PV-5 FOR PANEL DETAILEDINFORMATION.·IN CASE OF CONFLICT BETWEEN STRUCTURAL DRAWINGSAND ELECTRICAL DRAWINGS, THE MOST RIGIDREQUIREMENTS SHALL GOVERN.·THE CONTRACTOR/INSTALLER SHALL VERIFY ALL EXISTINGBUILDING INFORMATION SHOWN (DIMENSIONS, ROOF TOPPROJECTIONS, ETC.) AND NOTIFY THE ENGINEER OF ANYDISCREPANCIES PRIOR TO INSTALLATIONS OF PV SYSTEM.·THE CONTRACTOR/INSTALLER SHALL VERIFY ANDCOORDINATE EXISTING OPENINGS, ROOF TOP UNITS, VENTPIPES, ETC. SHOWN ON DRAWINGS. IF THERE IS ADISCREPANCY BETWEEN DRAWINGS, IT IS THECONTRACTORS/INSTALLER'S RESPONSIBILITY TO NOTIFYENGINEER PRIOR TO PERFORMING THE WORK.·ALL CONSTRUCTION IS TO BE PERFORMED IN STRICTCONFORMANCE WITH ALL APPLICABLE TOWN, COUNTY &STATE REGULATIONS AND/OR ANY OTHER GOVERNINGBODIES.· DO NOT SCALE THESE DRAWINGS, USE DIMENSIONS.CONTRACTOR MUST CONDUCT ROOF SURVEY TO VERIFYDIMENSIONS SHOWN ON PLAN PRIOR TO INSTALLATION. IFTHERE IS A DISCREPANCY IT IS CONTRACTOR/INSTALLER'SRESPONSIBILITY TO NOTIFY THE ENGINEER IMMEDIATELY.·LOCATED IN AREAS NOT REQUIRING PLACEMENT OF GROUNDLADDERS OVER OPENINGS SUCH AS DOORS OR WINDOWS.·LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTIONIN LOCATIONS WHERE ACCESS POINT DOES NOT CONFLICTWITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS,WIRES, OR SIGNS.·DISCONNECT MEANS MUST HAVE DEDICATED CLEARUNOBSTRUCTED WORKING SPACE NOT LESS THAN 3' DEEPBY 2.5' WIDE TO NOT LESS THAN 6.5' ABOVE WALKABLESURFACES IN FRONT OF DISTRIBUTION PANEL.·ALL SOLAR MODULES, EQUIPMENT, AND METALLICCOMPONENTS TO BE BONDED.·PV ARRAY NOT TO EXCEED HIGHEST POINT OF THE ROOF.·RAPID SHUTDOWN IS ACTIVED AT THE INVERTER BY THE ACDISCONNECT.GOVERNING CODES:2017 NATIONAL ELECTRICAL CODE (NEC)2018 INTERNATIONAL BUILDING CODE (IBC)2018 INTERNATIONAL RESIDENTIAL CODE (IRC)2018 INTERNATIONAL FIRE CODE (IFC)2018 INTERNATIONAL MECHANICAL CODE (IMC)2018 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)
MSPUMACDPVMCBJB~172.37'~111.85'~185.21'~99.01'~
2
0
.
1
6
'19'-0"21'-0"101'-11"25'-0"MSPUMACDPVMCBJBSITE PLAN WITH ROOF PLANREVSHEET NAMESHEET NUMBERDATEDESCRIPTIONVERSIONPV-1 PROJECT NAMEUR05/08/2022INITIAL RELEASEJODY RAWLINGS
217 N 2ND E,
REXBURG, ID 83440 USA
APN# RPRRXB10124331
UTILITY: PACIFICCORP.
AHJ: CITY OF REXBURGSHEET SIZEANSI B11" X 17"HORIZON PWR SC LLC237 N 2ND E SUITE 202 ,REXBURG ID,83440 USACSLB # :RCE-56878TEL: (888) 468-7180Email: permitting@horizonpwr.comSITE PLAN WITHROOF PLAN1SCALE: 1/32" = 1'-0" ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THEPLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS ORDOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION INLOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEADOBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS.ENLARGE VIEW1ASCALE: 1/32" = 1'-0"(N) 3/4" OR GREATER EMTCONDUIT RUN( 7/8"THROUGH THE ATTIC)(N) JUNCTION BOX(E) UTILITY METER(N) PRODUCTION METER(N) 30A NON-FUSED AC DISCONNECT(N) ENPHASE IQ COMBINER BOX 3(E) 200A MAIN SERVICE PANELWITH (E) 200A MAIN BREAKERENLARGE VIEW 1APROPERTY LINEPROPERTY LINE
PROPERTY LINE PROPERTY LINE(E) TREES (TYP.)ONE- STORYHOUSEEXISTINGDRIVEWAYN 2ND EROOF #1(12) HANWHA Q CELLS Q.PEAK DUOBLK ML-G10+ (400W) MODULESROOF ACCESS POINTEXISTINGPARKING
MSPUMACDPVMCBJB14'-0"6'-2"11'-4"7'-11"42'-0"26'-4"REVSHEET NAMESHEET NUMBERDATEDESCRIPTIONVERSIONPV-2 PROJECT NAMEUR05/08/2022INITIAL RELEASEJODY RAWLINGS
217 N 2ND E,
REXBURG, ID 83440 USA
APN# RPRRXB10124331
UTILITY: PACIFICCORP.
AHJ: CITY OF REXBURGSHEET SIZEANSI B11" X 17"HORIZON PWR SC LLC237 N 2ND E SUITE 202 ,REXBURG ID,83440 USACSLB # :RCE-56878TEL: (888) 468-7180Email: permitting@horizonpwr.comROOF PLAN WITHMODULESROOF PLAN WITH MODULESSCALE: 3/32" = 1'-0"174.0"41.1"PHOTOVOLTAIC MODULESHANWHA Q CELLS Q.PEAK DUO BLKML-G10+ (400W)MODULE TYPE, DIMENSIONS & WEIGHTNUMBER OF MODULES = 12 MODULESMODULE TYPE = HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULESMODULE WEIGHT = 48.5 LBS / 22.0 KG.MODULE DIMENSIONS = 74.0"X 41.1" = 21.12 SFUNIT WEIGHT OF ARRAY = 2.30 PSF· PLUMBING VENTS, SKYLIGHTS AND MECHANICAL VENTS SHALL NOT BE COVERED, MOVED, RE-ROUTED OR RE-LOCATED.ALL ELECTRICAL EQUIPMENT, INVERTERS, DISCONNECTS,MAIN SERVICE PANELS, ETC. SHALL NOT BE INSTALLEDWITHIN 3’ OF THE GAS METERS SUPPLY OR DEMAND PIPING.NOTE: ACTUAL ROOF CONDITIONS AND TRUSSES(OR SEAM) LOCATIONS MAY VARY. INSTALL PERMANUFACTURER(S) INSTALLATION GUIDELINESAND ENGINEERED SPANS FOR ATTACHMENTSLEGEND- UTILITY METERMSP- MAIN SERVICE PANEL- AC DISCONNECT- JUNCTION BOX- ENPHASE IQCOMBINER BOX 3- VENT, ATTIC FAN(ROOF OBSTRUCTION)- ROOF ATTACHMENT- TRUSSES- CONDUIT- FIRE PATHWAY- CHIMNEY- PRODUCTION METERUMACDCBJBPVM(E) COMP SHINGLE ROOF (TYP.)(N) (23) IRONRIDGE FLASHFOOT2ATTACHMENTS SPACED AT 48" O.C.(E) UTILITY METER(N) PRODUCTION METER(N) 30A NON-FUSED AC DISCONNECT(N) ENPHASE IQ COMBINER BOX 3(E) CHIMNEY (TYP.)(N) JUNCTION BOX(N) 3/4" OR GREATER EMT CONDUITRUN( 7/8" ABOVE THE ROOF)ARRAY AREA & ROOF AREA CALC'SROOF# OFMODULESARRAYAREA(Sq. Ft.)ROOFAREA(Sq. Ft.)ROOFAREACOVERED BYARRAY (%)#112253.452256.3211.23ROOF DESCRIPTIONROOF TYPECOMP SHINGLE ROOFROOFROOFTILTAZIMUTHTRUSSESSIZETRUSSESSPACING#120°180°2"x4"24" O.C.ROOF #1(12) HANWHA Q CELLS Q.PEAK DUOBLK ML-G10+ (400W) MODULESN 2ND EFRONT YARDREAR YARDROOF #1TILT - 20° AZIMUTH - 180°18" FIRE PATHWAY18" FIRE PATHWAY36" FIRE PATHWAY
36" FIRE PATHWAY(E) 200A MAIN SERVICE PANELWITH (E) 200A MAIN BREAKER(N) IRONRIDGE XR 100 RAIL(E) 2"X4" TRUSSES @ 24" O.C. (TYP.)BILL OF MATERIALSEQUIPMENTQTYDESCRIPTIONRAIL06IRONRIDGE XR 100 RAILSPLICE04XR-BONDED SPLICEMID CLAMP22IRONRIDGE MID CLAMP-UFOEND CLAMP04IRONRIDGE END CLAMP-STOPPERSLEEVESATTACHMENT23IRONRIDGE FLASHFOOT2GROUNDING LUG1XR-LUG
REVSHEET NAMESHEET NUMBERDATEDESCRIPTIONVERSIONPV-3 PROJECT NAMEUR05/08/2022INITIAL RELEASEJODY RAWLINGS
217 N 2ND E,
REXBURG, ID 83440 USA
APN# RPRRXB10124331
UTILITY: PACIFICCORP.
AHJ: CITY OF REXBURGSHEET SIZEANSI B11" X 17"HORIZON PWR SC LLC237 N 2ND E SUITE 202 ,REXBURG ID,83440 USACSLB # :RCE-56878TEL: (888) 468-7180Email: permitting@horizonpwr.comATTACHMENTDETAILATTACHMENT DETAILSCALE: NTS1ATTACHMENT DETAIL (ENLARGED VIEW)SCALE: NTS2NOTE: ACTUAL ROOF CONDITIONS AND TRUSSES (OR SEAM)LOCATIONS MAY VARY. INSTALL PER MANUFACTURER(S)INSTALLATION GUIDELINES AND ENGINEERED SPANS FORATTACHMENTSENLARGED VIEWPV MODULE 2"x4" TRUSSES @ 24" O.C(E) COMP SHINGLE ROOFIRONRIDGE INTEGRATEDGOUNDING & END/MID CLAMPALUMN. "L" BRACKETW/3/8" SS BOLT & NUTIRONRIDGE FLASHFOOT2ATTACHMENTS (E) 2"x4" TRUSSES @ 24" O.C5/16"x3.5" SS LAG BOLT WITHMIN 212" THREAD EMBEDMENT,SEALED PENETRATIONPV MODULES(E) COMP SHINGLE ROOFIRONRIDGE XR 100 RAIL2.5" MIN.EMBEDMENTROOF / DECK MEMBRANE
REVSHEET NAMESHEET NUMBERDATEDESCRIPTIONVERSIONPV-4 PROJECT NAMEUR05/08/2022INITIAL RELEASEJODY RAWLINGS
217 N 2ND E,
REXBURG, ID 83440 USA
APN# RPRRXB10124331
UTILITY: PACIFICCORP.
AHJ: CITY OF REXBURGSHEET SIZEANSI B11" X 17"HORIZON PWR SC LLC237 N 2ND E SUITE 202 ,REXBURG ID,83440 USACSLB # :RCE-56878TEL: (888) 468-7180Email: permitting@horizonpwr.comBRANCH LAYOUTSCALE: 1/8" = 1'-0"1BRANCH LAYOUT(12) HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULES(12) ENPHASE ENERGY IQ7A-72-2-US MICRO-INVERTERS(02) BRANCHES OF 06 MODULES CONNECTED IN PARALLEL3'-0"36" FIRE PATHWAY18"18" FIRE PATHWAY36" FIRE PATHWAY
36" FIRE PATHWAY18" FIRE PATHWAY18" FIRE PATHWAYROOF #1(12) HANWHA Q CELLS Q.PEAK DUOBLK ML-G10+ (400W) MODULES(12) ENPHASE ENERGY IQ7A-72-2-USMICRO-INVERTERSBRANCH #2N 2ND EFRONT YARDREAR YARDBRANCH #1
REVSHEET NAMESHEET NUMBERDATEDESCRIPTIONVERSIONPV-5 PROJECT NAMEUR05/08/2022INITIAL RELEASEJODY RAWLINGS
217 N 2ND E,
REXBURG, ID 83440 USA
APN# RPRRXB10124331
UTILITY: PACIFICCORP.
AHJ: CITY OF REXBURGSHEET SIZEANSI B11" X 17"HORIZON PWR SC LLC237 N 2ND E SUITE 202 ,REXBURG ID,83440 USACSLB # :RCE-56878TEL: (888) 468-7180Email: permitting@horizonpwr.comELECTRICAL LINEDIAGRAMELECTRICAL LINE DIAGRAMSCALE: NTS1UTILITY PROVIDER:MAIN SERVICE VOLTAGE:MAIN PANEL BRAND:MAIN SERVICE PANEL:MAIN CIRCUIT BREAKER RATING:MAIN SERVICE LOCATION:SERVICE FEED SOURCE:PACIFICCORP.240VGENERAL ELECTRIC(E) 200A(E) 200ANORTHSERVICE INFO.OVERHEADBILL OF MATERIALSEQUIPMENTQTYDESCRIPTIONSOLAR PV MODULE12HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULESINVERTER12ENPHASE ENERGY IQ7A-72-2-US MICRO-INVERTERSJUNCTION BOX1600V, 55A MAX, 4 INPUTS, MOUNTED ON ROOF FOR WIRE & CONDUIT TRANSITIONCOMBINER BOX1ENPHASE IQ COMBINER 3, X-IQ-AM1-240-3AC DISCONNECT130A NON-FUSED, AC DISCONNECT 240VAC, NEMA 3R, UL LISTEDPV METER1PRODUCTION METER(E) 200A MAIN SERVICE PANEL WITH(E) 200A MAIN BREAKER (TOP FED)LEXISTINGGROUNDINGSYSTEM200ABI-DIRECTIONALUTILITY METER1-PHASE, 3-W,120V/240V, 60Hz12 MODULES X 1.45A= 17.40 A17.40A X 1.25 = 21.75 A(3) #10 AWG THWN(1) #8 AWG THWN GNDIN 3/4" EMT CONDUIT RUNG(N) AC DISCONNECT30A NON-FUSED,240 VAC(12) HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULES(12) ENPHASE ENERGY IQ7A-72-2-US MICRO-INVERTERS(02) BRANCHES OF 06 MODULES CONNECTED IN PARALLELSYSTEM SIZE:- 12 x 400W = 4.80 kWDCSYSTEM SIZE:- 12 x 290W = 3.48 kWACM(N) PV METER(N) 30A PV BREAKER30AINTERCONNECTION120% RULE - NEC 705.12(B)(2)(3)(b)UTILITY FEED + SOLAR BACKFEED200A + 30A = 230ABUSS RATING x 120%200A x 120% = 240ANOTE: TANDEM EXISTING BREAKERS TOMAKE ROOM FOR NEW PV BREAKERTERMINATOR CAP ON LAST CABLECONNECTOR AC TRUNK CABLE (TYP)06 MICRO-INVERTERS IN BRANCH CIRCUIT #206 MICRO-INVERTERS IN BRANCH CIRCUIT #1G(4) #10 AWG THWN-2(1) #8 AWG THWN-2 GNDIN 3/4" EMT CONDUIT RUNJUNCTION BOXGENVOYMICRO-INVERTER20A10A20A(2) Q-CABLE(1) #6 BARE CU GND(N) ENPHASE IQ COMBINER 3,X-IQ-AM1-240-3
REVSHEET NAMESHEET NUMBERDATEDESCRIPTIONVERSIONPV-6 PROJECT NAMEUR05/08/2022INITIAL RELEASEJODY RAWLINGS
217 N 2ND E,
REXBURG, ID 83440 USA
APN# RPRRXB10124331
UTILITY: PACIFICCORP.
AHJ: CITY OF REXBURGSHEET SIZEANSI B11" X 17"HORIZON PWR SC LLC237 N 2ND E SUITE 202 ,REXBURG ID,83440 USACSLB # :RCE-56878TEL: (888) 468-7180Email: permitting@horizonpwr.comELECTRICALCALCULATIONSOLAR MODULE SPECIFICATIONSMANUFACTURER / MODEL #HANWHA Q CELLS Q.PEAK DUO BLKML-G10+ (400W) MODULESVMP37.13IMP10.77VOC45.20ISC11.14MODULE DIMENSION74.0"L x 41.1"W x 1.57"D (In Inch)INVERTER SPECIFICATIONSMANUFACTURER / MODEL #ENPHASE ENERGY IQ7A-72-2-USNOMINAL OUTPUT VOLTAGE240 VACNOMINAL OUTPUT CURRENT1.45AAMBIENT TEMPERATURE SPECSWEATHER STATION: IDAHO FALLS FANNING FIELDRECORD LOW TEMP-26°AMBIENT TEMP (HIGH TEMP 2%)33°CONDUIT HEIGHT0.9"ROOF TOP TEMP33°CONDUCTOR TEMPERATURE RATE (ON ROOF)90°CONDUCTOR TEMPERATURE RATE (OFF ROOF)75°MODULE TEMPERATURE COEFFICIENT OF Voc-0.29%/°CPERCENT OF VALUESNUMBER OF CURRENTCARRYING CONDUCTORS IN EMT.804-6.707-9.5010-20ELECTRICAL NOTES1.) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION.2.) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 & 75 DEGREE C WET ENVIRONMENT.3.) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY.4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26.5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILLAPPLICABLE CODES AND STANDARDS.6.) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY.7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE.8.) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION.9.) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG.10.) THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVEAC CONDUCTOR AMPACITY CALCULATIONS:FROM JUNCTION BOX TO COMBINER BOX:AMBIENT TEMPERATURE ADJUSTMENT FOR EXPOSED CONDUITEXPECTED WIRE TEMP (°C): 33°TEMP CORRECTION PER TABLE 310.15(B)(2)(a): 0.96# OF CURRENT CARRYING CONDUCTORS: 4CONDUIT FILL CORRECTION PER NEC 310.15(B)(3)(a): 0.8CIRCUIT CONDUCTOR SIZE: 10 AWGCIRCUIT CONDUCTOR AMPACITY: 40AREQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B):1.25 X # MICRO-INVERTERS (MAX. BRANCH LENGTH) X MAX OUTPUTCURRENT1.25 X 06 X 1.45A = 10.88ADERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE310.15(B)(2)(a)TEMP CORR. PER NEC TABLE 310.15(B)(2)(a) XCONDUIT FILL CORR. PER NEC 310.15(B)(3)(a) XCIRCUIT CONDUCTOR AMPACITY =0.96 X0.8X 40 = 30.72AAC CONDUCTOR AMPACITY CALCULATIONS:FROM COMBINER BOX TO INTERCONNECTION:# OF INVERTERS: 12EXPECTED WIRE TEMP (°C): 33°TEMP CORRECTION PER TABLE 310.15(B)(2)(a): 0.94# OF CURRENT CARRYING CONDUCTORS: 3CONDUIT FILL PER NEC 310.15(B)(3)(a): 1.0CIRCUIT CONDUCTOR SIZE:10 AWGCIRCUIT CONDUCTOR AMPACITY: 35 AREQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B):1.25 X # MICRO-INVERTERS X MAX OUTPUT CURRENT =1.25 X 1.45 X 12 = 21.75ADERATED AMPACITY OF CIRCUIT CONDUCTORS PER NEC TABLE 310.16:TEMP CORR. PER NEC TABLE 310.15(B)(2)(a) XCONDUIT FILL CORR. PER NEC 310.15(B)(3)(a) XCIRCUIT CONDUCTOR AMPACITY =0.94 X 1.0 X 35= 32.9ARESULT SHOULD BE GREATER THAN (10.88A) OTHERWISE LESS THEENTRY FOR CIRCUIT CONDUCTOR SIZE AND AMPACITYRESULT SHOULD BE GREATER THAN (21.75A) OTHERWISE LESS THEENTRY FOR CIRCUIT CONDUCTOR SIZE AND AMPACITYELECTRICAL CALCULATIONSCALE: NTS1
REVSHEET NAMESHEET NUMBERDATEDESCRIPTIONVERSIONPV-7 PROJECT NAMEUR05/08/2022INITIAL RELEASEJODY RAWLINGS
217 N 2ND E,
REXBURG, ID 83440 USA
APN# RPRRXB10124331
UTILITY: PACIFICCORP.
AHJ: CITY OF REXBURGSHEET SIZEANSI B11" X 17"HORIZON PWR SC LLC237 N 2ND E SUITE 202 ,REXBURG ID,83440 USACSLB # :RCE-56878TEL: (888) 468-7180Email: permitting@horizonpwr.comWARNING LABELS &PLACARD CAUTION !POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THEFOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWNAT:MAIN SERVICE PANEL & UTILITY METER, ACDISCONNECT & COMBINER BOX, PRODUCTION METER(N) PV MODULESWARNINGPOWER SOURCE OUTPUTCONNECTIONDO NOT RELOCATE THISOVERCURRENT DEVICELABEL LOCATION:AC DISCONNECT & INVERTER(PER CODE: NEC690.54)PHOTOVOLTAIC SYSTEM AC DISCONNECTRATED AC OPERATING CURRENT 17.4 AMPSAC NOMINAL OPERATING VOLTAGE 240 VOLTSLABEL LOCATION:SERVICE PANEL IF SUM OF BREAKERS EXCEEDSPANEL RATING(PER CODE: NEC 705.12 (B)(2)(3)(b)LABEL LOCATION:AC & DC DISCONNECT AND SUB PANEL(PER CODE: NEC 690.13(B))WARNING:PHOTOVOLTAICPOWER SOURCELABEL LOCATION:EMT / CONDUIT RACEWAYS(PER CODE: NEC 690.31(G)(3)TERMINALS ON THE LINE AND LOADSIDES MAY BE ENERGIZED IN THEOPEN POSITIONWARNINGELECTRIC SHOCK HAZARD!LABEL LOCATION:MAIN SERVICE PANEL & NET METER(PER CODE: NEC 705.12(D)(3), NEC705.12(B)(3-4) & NEC 690.59)MAIN PHOTOVOLTAICSYSTEM DISCONNECTLABEL LOCATION:MAIN SERVICE DISCONNECT / UTILITY METER(PER CODE: NEC 690.13(B))LABEL LOCATION:AC DISCONNECT, DC DISCONNECT, POINT OFINTERCONNECTION(PER CODE: 605.11.3.1(1) & 690.56(C)(1)(a)) WARNING DUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEM!SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNTURN RAPIDSHUTDOWN SWITCHTO THE "OFF" POSITIONTO SHUTDOWN PVSYSTEM AND REDUCESHOCK HAZARD INARRAYSOLAR ELECTRICPV PANELSPHOTOVOLTAICAC DISCONNECTLABEL LOCATION:AC DISCONNECTNEC 690.13(B)RAPID SHUTDOWN SWITCHFOR SOLAR PV SYSTEMLABEL LOCATION:RAPID SHUTDOWN(PER CODE: NEC 690.56(C)(3)!(N) PRODUCTION METER(E) UTILITY METER(N) AC NON-FUSED DISCONNECT(E) 200A MAIN SERVICE PANELWITH (E) 200A MAIN BREAKER(N) COMBINER BOX 3217 N 2ND ESOLAR METERPARALLELGENERATION ONSITELOCATION: NEXT TO AC DISCONNECT3"4.5"MANUALDISCONNECTFOR PARALLELGENERATION4"2"LOCATION: NEXT TO METER
REVSHEET NAMESHEET NUMBERDATEDESCRIPTIONVERSIONPV-8 PROJECT NAMEUR05/08/2022INITIAL RELEASEJODY RAWLINGS
217 N 2ND E,
REXBURG, ID 83440 USA
APN# RPRRXB10124331
UTILITY: PACIFICCORP.
AHJ: CITY OF REXBURGSHEET SIZEANSI B11" X 17"HORIZON PWR SC LLC237 N 2ND E SUITE 202 ,REXBURG ID,83440 USACSLB # :RCE-56878TEL: (888) 468-7180Email: permitting@horizonpwr.comADDITIONAL NOTES 1.EACH MODULE TO BE GROUNDED USING THE SUPPLIED CONNECTION POINT PERMANUFACTURER'S REQUIREMENTS. ALL SOLAR MODULES, EQUIPMENT, ANDMETALLIC COMPONENTS ARE TO BE BONDED. IF THE EXISTING GROUNDINGELECTRODE SYSTEM CAN NOT BE VERIFIED OR IS ONLY METALLIC WATER PIPING,IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTALGROUNDING ELECTRODE.2.ALL PLAQUES AND SIGNAGE REQUIRED BY THE LATEST EDITION OF NATIONALELECTRICAL CODE. LABEL SHALL BE METALLIC OR PLASTIC, ENGRAVED OR MACHINE PRINTED IN A CONTRASTING COLOR TO THE PLAQUE. PLAQUE SHALL BE UV RESISTANT IF EXPOSED TO SUNLIGHT.3.AC CONDUCTORS SHALL BE RUN IN EMT AND SHALL BE LABELED, "CAUTION ACCIRCUIT" OR EQUIV. EVERY 5 FT.4.EXPOSED NON-CURRENT CARRYING METAL PARTS OF ELECTRICAL EQUIPMENTSHALL BE GROUNDED IN ACCORDANCE WITH 250.134 OR 250.136(A).5.CONFIRM LINE SIDE VOLTAGE AT ELECTRIC UTILITY SERVICE PRIOR TOCONNECTING INVERTER. VERIFY SERVICE VOLTAGE IS WITHIN INVERTERVOLTAGE OPERATIONAL RANGE.6.OUTDOOR EQUIPMENT SHALL BE NEMA-3R RATED OR BETTER.7.ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS ANDANCHOR CONDUIT RUNS AS REQUIRED PER NEC.8.ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICALMEANS DESIGNED AND LISTED FOR SUCH USE, AND FOR ROOF-MOUNTEDSYSTEMS, WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF THEROOF SURFACE. NEC 110.2 - 110.4 / 300.4
REVSHEET NAMESHEET NUMBERDATEDESCRIPTIONVERSIONPV-9 PROJECT NAMEUR05/08/2022INITIAL RELEASEJODY RAWLINGS
217 N 2ND E,
REXBURG, ID 83440 USA
APN# RPRRXB10124331
UTILITY: PACIFICCORP.
AHJ: CITY OF REXBURGSHEET SIZEANSI B11" X 17"HORIZON PWR SC LLC237 N 2ND E SUITE 202 ,REXBURG ID,83440 USACSLB # :RCE-56878TEL: (888) 468-7180Email: permitting@horizonpwr.comSPEC SHEETS
REVSHEET NAMESHEET NUMBERDATEDESCRIPTIONVERSIONPV-10 PROJECT NAMEUR05/08/2022INITIAL RELEASEJODY RAWLINGS
217 N 2ND E,
REXBURG, ID 83440 USA
APN# RPRRXB10124331
UTILITY: PACIFICCORP.
AHJ: CITY OF REXBURGSHEET SIZEANSI B11" X 17"HORIZON PWR SC LLC237 N 2ND E SUITE 202 ,REXBURG ID,83440 USACSLB # :RCE-56878TEL: (888) 468-7180Email: permitting@horizonpwr.comSPEC SHEETS
REVSHEET NAMESHEET NUMBERDATEDESCRIPTIONVERSIONPV-11 PROJECT NAMEUR05/08/2022INITIAL RELEASEJODY RAWLINGS
217 N 2ND E,
REXBURG, ID 83440 USA
APN# RPRRXB10124331
UTILITY: PACIFICCORP.
AHJ: CITY OF REXBURGSHEET SIZEANSI B11" X 17"HORIZON PWR SC LLC237 N 2ND E SUITE 202 ,REXBURG ID,83440 USACSLB # :RCE-56878TEL: (888) 468-7180Email: permitting@horizonpwr.comSPEC SHEETS
REVSHEET NAMESHEET NUMBERDATEDESCRIPTIONVERSIONPV-12 PROJECT NAMEUR05/08/2022INITIAL RELEASEJODY RAWLINGS
217 N 2ND E,
REXBURG, ID 83440 USA
APN# RPRRXB10124331
UTILITY: PACIFICCORP.
AHJ: CITY OF REXBURGSHEET SIZEANSI B11" X 17"HORIZON PWR SC LLC237 N 2ND E SUITE 202 ,REXBURG ID,83440 USACSLB # :RCE-56878TEL: (888) 468-7180Email: permitting@horizonpwr.comSPEC SHEETS
REVSHEET NAMESHEET NUMBERDATEDESCRIPTIONVERSIONPV-13 PROJECT NAMEUR05/08/2022INITIAL RELEASEJODY RAWLINGS
217 N 2ND E,
REXBURG, ID 83440 USA
APN# RPRRXB10124331
UTILITY: PACIFICCORP.
AHJ: CITY OF REXBURGSHEET SIZEANSI B11" X 17"HORIZON PWR SC LLC237 N 2ND E SUITE 202 ,REXBURG ID,83440 USACSLB # :RCE-56878TEL: (888) 468-7180Email: permitting@horizonpwr.comSPEC SHEETS
REVSHEET NAMESHEET NUMBERDATEDESCRIPTIONVERSIONPV-14 PROJECT NAMEUR05/08/2022INITIAL RELEASEJODY RAWLINGS
217 N 2ND E,
REXBURG, ID 83440 USA
APN# RPRRXB10124331
UTILITY: PACIFICCORP.
AHJ: CITY OF REXBURGSHEET SIZEANSI B11" X 17"HORIZON PWR SC LLC237 N 2ND E SUITE 202 ,REXBURG ID,83440 USACSLB # :RCE-56878TEL: (888) 468-7180Email: permitting@horizonpwr.comSPEC SHEETS
REVSHEET NAMESHEET NUMBERDATEDESCRIPTIONVERSIONPV-15 PROJECT NAMEUR05/08/2022INITIAL RELEASEJODY RAWLINGS
217 N 2ND E,
REXBURG, ID 83440 USA
APN# RPRRXB10124331
UTILITY: PACIFICCORP.
AHJ: CITY OF REXBURGSHEET SIZEANSI B11" X 17"HORIZON PWR SC LLC237 N 2ND E SUITE 202 ,REXBURG ID,83440 USACSLB # :RCE-56878TEL: (888) 468-7180Email: permitting@horizonpwr.comSPEC SHEETS
REVSHEET NAMESHEET NUMBERDATEDESCRIPTIONVERSIONPV-16 PROJECT NAMEUR05/08/2022INITIAL RELEASEJODY RAWLINGS
217 N 2ND E,
REXBURG, ID 83440 USA
APN# RPRRXB10124331
UTILITY: PACIFICCORP.
AHJ: CITY OF REXBURGSHEET SIZEANSI B11" X 17"HORIZON PWR SC LLC237 N 2ND E SUITE 202 ,REXBURG ID,83440 USACSLB # :RCE-56878TEL: (888) 468-7180Email: permitting@horizonpwr.comSPEC SHEETS
REVSHEET NAMESHEET NUMBERDATEDESCRIPTIONVERSIONPV-17 PROJECT NAMEUR05/08/2022INITIAL RELEASEJODY RAWLINGS
217 N 2ND E,
REXBURG, ID 83440 USA
APN# RPRRXB10124331
UTILITY: PACIFICCORP.
AHJ: CITY OF REXBURGSHEET SIZEANSI B11" X 17"HORIZON PWR SC LLC237 N 2ND E SUITE 202 ,REXBURG ID,83440 USACSLB # :RCE-56878TEL: (888) 468-7180Email: permitting@horizonpwr.comSPEC SHEETS
REVSHEET NAMESHEET NUMBERDATEDESCRIPTIONVERSIONPV-18 PROJECT NAMEUR05/08/2022INITIAL RELEASEJODY RAWLINGS
217 N 2ND E,
REXBURG, ID 83440 USA
APN# RPRRXB10124331
UTILITY: PACIFICCORP.
AHJ: CITY OF REXBURGSHEET SIZEANSI B11" X 17"HORIZON PWR SC LLC237 N 2ND E SUITE 202 ,REXBURG ID,83440 USACSLB # :RCE-56878TEL: (888) 468-7180Email: permitting@horizonpwr.comSPEC SHEETS
REVSHEET NAMESHEET NUMBERDATEDESCRIPTIONVERSIONPV-19 PROJECT NAMEUR05/08/2022INITIAL RELEASEJODY RAWLINGS
217 N 2ND E,
REXBURG, ID 83440 USA
APN# RPRRXB10124331
UTILITY: PACIFICCORP.
AHJ: CITY OF REXBURGSHEET SIZEANSI B11" X 17"HORIZON PWR SC LLC237 N 2ND E SUITE 202 ,REXBURG ID,83440 USACSLB # :RCE-56878TEL: (888) 468-7180Email: permitting@horizonpwr.comSPEC SHEETS
REVSHEET NAMESHEET NUMBERDATEDESCRIPTIONVERSIONPV-20 PROJECT NAMEUR05/08/2022INITIAL RELEASEJODY RAWLINGS
217 N 2ND E,
REXBURG, ID 83440 USA
APN# RPRRXB10124331
UTILITY: PACIFICCORP.
AHJ: CITY OF REXBURGSHEET SIZEANSI B11" X 17"HORIZON PWR SC LLC237 N 2ND E SUITE 202 ,REXBURG ID,83440 USACSLB # :RCE-56878TEL: (888) 468-7180Email: permitting@horizonpwr.comSPEC SHEETS