Loading...
HomeMy WebLinkAboutLOAD SHORT FORM - 22-00317 - 787 S 2470 W - New SFRCalculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-May-05 17:27:59 Rig ht-Su ite® U niv er sal 20 19 19 .0.13 RSU2 0477 Page 1 S:\High Country\Wrightsoft\SF9B14 Savannah.rup Calc = MJ8 House faces: NE SF9B14Job:Load Short Form Date:Entire House Vince ByramBy: SAVANNAH CPlan:Kartchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 Project Information Cody Puzey, Kartchner HomesFor: 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Design Information InfiltrationClgHtg SimplifiedMethod89-6Outside db (°F) Semi-tightConstruction quality7568Inside db (°F) 0Fireplaces1474Design TD (°F) H-Daily range 5050Inside humidity (%) -3157Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Lennox Make Lennox Trade LENNOX Trade LENNOX Model ML195UH070XP36B-*Cond 13ACXN030-230-** AHRI ref 4805339 Coil SK6(6,9)30++TD AHRI ref 10317778 Efficiency 95 AFUE Efficiency 11.0 EER, 13 SEER Heating input Btuh66000 Sensible cooling Btuh19040 Heating output Btuh64000 Latent cooling Btuh8160 Temperature rise °F60 Total cooling Btuh27200 Actual air flow cfm1150 Actual air flow cfm907 Air flow factor cfm/Btuh0.033 Air flow factor cfm/Btuh0.067 Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 1.00 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Room1 270 3649 2015 121 135 Room2 108 978 286 32 19 Room3 54 80 43 3 3 Room4 168 2069 421 68 28 Room5 77 534 101 18 7 Room6 55 457 72 15 5 Room7 154 4311 792 143 53 Room8 156 2897 751 96 50 Room9 384 4125 2878 136 193 Room10 42 0 0 0 0 Room11 143 2403 1259 79 84 Room12 24 0 0 0 0 Room13 60 944 164 31 11 Room14 956 12340 4764 408 319 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-May-05 17:27:59 Rig ht-Su ite® U niv er sal 20 19 19 .0.13 RSU2 0477 Page 2 S:\High Country\Wrightsoft\SF9B14 Savannah.rup Calc = MJ8 House faces: NE Entire House d 2651 34786 13548 1150 907 Other equip loads 4835 915 Equip. @ 0.94 RSM 13595 Latent cooling 0 TOTALS 2651 39621 13595 1150 907 2022-May-05 17:27:59 Rig ht-Su ite® U niv er sal 20 19 19 .0.13 RSU2 0477 Page 1 S:\High Country\Wrightsoft\SF9B14 Savannah.rup Calc = MJ8 House faces: NE SF9B14Job:Building Analysis Date:Entire House Vince ByramBy: SAVANNAH CPlan:Kartchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 Project Information Cody Puzey, Kartchner HomesFor: 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Design Conditions Location:CoolingHeatingIndoor: 7568Indoor temp era ture (°F)Idaho Falls, ID, US 1474Design TD (°F)ft4741Elevation: 5050Relative humidity (%)°N44Latitude:Outdoor:-31.557.0Moisture difference (gr/lb)CoolingHeating Infiltration:89-6Dry bul b (°F) SimplifiedMethod)H(34-Da ily ra nge (°F) Semi-tightConstruction quality60-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing OtherCeilings Floors Infiltration Ventilation % of loadBtuhBtuh/ft²Component 24.697644.8Walls 25.0988822.2Glazing 1.246611.1Doors 5.722661.5Ceilings 14.256333.73.7Floors 17.167692.7Infiltration 00Ducts 00Piping 00Humidification 12.24835Ventilation0Adjustments 100.039621Total Cooling Walls Glazing Other Ceilings InfiltrationVentilation % of loadBtuhBtuh/ft²Component 6.79630.5Walls 71.81038823.3Glazing 1.62255.4Doors 8.912860.8Ceilings 000Floors 4.76860.3Infiltration 00Ducts 6.3915Ventilation 00Internal gains 00Blower 0Adjustments 100.014463Total Latent Cooling Load = 0 Btuh Overall U-va lue = 0.0 68 Btuh/ft²-°F Data entries checked. 2022-May-05 17:28:00 Rig ht-Su ite® U niv er sal 20 19 19 .0.13 RSU2 0477 Page 1 S:\High Country\Wrightsoft\SF9B14 Savannah.rup Calc = MJ8 House faces: NE SF9B14Job:Component Constructions Date:Entire House Vince ByramBy: SAVANNAH CPlan:Kartchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 Project Information Cody Puzey, Kartchner HomesFor: 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Design Conditions Location:CoolingHeatingIndoor: 7568Indoor temp era ture (°F)Idaho Falls, ID, US 1474Design TD (°F)ft4741Elevation: 5050Relative humidity (%)°N44Latitude: Outdoor:-31.557.0Moisture difference (gr/lb)CoolingHeating Infiltration:89-6Dry bul b (°F) SimplifiedMethod)H(34-Da ily ra nge (°F) Semi-tightConstruction quality60-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls Frm wall, vnl ext, 3/8" wood shth, r-22 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 1970.4719994.8122.00.065416n 3040.4730854.8122.00.065641e 2240.4722704.8122.00.065472s 2380.4724104.8122.00.065501w 9630.4797644.8122.00.0652030all Partitions (none) Windows 2 glazing, clr outr, air gas, mtl no brk frm mat, clr innr, 1/4" gap, 1/8" thk: 2 glazing, clr outr, air gas, mtl no brk frm mat, clr innr, 1/4" gap, 1/8" thk; NFRC rated (SHGC=0.32) 81210.3175422.200.30079n 143218.6170922.200.30077s 225434.1146522.200.30066w 449720.3492822.200.300222all 2 glazing, clr outr, air gas, vnl frm mat, clr innr, 1/4" gap, 1/8" thk: 2 glazing, clr outr, air gas, vnl frm mat, clr innr, 1/4" gap, 1/8" thk; NFRC rated (SHGC=0.32) 124710.3269522.200.300121n 46518.655522.200.30025s 262934.1170922.200.30077w 434119.4495922.200.300223all Doors metal: Door, mtl pur core type 2255.3646611.110.50.15042s Ceilings 16B-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 1/2" gypsum board int fnsh 12860.8422661.4850.00.0201531 Floors 21A-28c: Bg floor, heavy dry or light damp soil, 6.5' depth, carpet flr fnsh 0019261.6300.0221183 22A-cpm: Bg floor, heavy dry or light damp soil, on grade depth, carpet flr fnsh 00370787.301.18042 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-May-05 17:28:00 Rig ht-Su ite® U niv er sal 20 19 19 .0.13 RSU2 0477 Page 1 S:\High Country\Wrightsoft\SF9B14 Savannah.rup Calc = MJ8 House faces: NE SF9B14Job:Project Summary Date:Entire House Vince ByramBy: SAVANNAH CPlan:Kartchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 Project Information Cody Puzey, Kartchner HomesFor:3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Notes: Design Information Idaho Falls, ID, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F-6 Outside db °F89Inside db °F68 Inside db °F75 Design TD °F74 Design TD °F14Daily range H Relative humidity %50Moisture difference gr/lb-31 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh34786 Structure Btuh13548 Ducts Btuh0 Ducts Btuh0Central vent (71 cfm)4835 Btuh Central vent (71 cfm)Btuh915 Outside air Outside airHumidificationBtuh0Blower Btuh0 Piping Btuh0Equipment load Btuh39621 Use manufacturer's data n Rate/swing multiplier 0.94InfiltrationEquipment sensible load Btuh13595 Method Latent Cooling Equipment Load SizingSimplified Construction quality Semi-tight0Fireplaces Structure Btuh-954 Ducts Btuh0Central vent (71 cfm)Btuh-1271 CoolingHeating Outside air26512651Area (ft²)Equipment latent load Btuh0 2120921209Volume (ft³)Air changes/hour 0.150.28 Equipment Total Load (Sen+Lat)Btuh13595 Equiv. AVF (cfm)5399 Req. total capacity at 0.70 SHR ton1.6 Heating Equipment Summary Cooling Equipment Summary Make Lennox Make LennoxTradeLENNOXTradeLENNOX Model ML195UH070XP36B-*Cond 13ACXN030-230-**AHRI ref 4805339 Coil SK6(6,9)30++TD AHRI ref 10317778Efficiency95 AFUE Efficiency 11.0 EER, 13 SEER Heating input Btuh66000 Sensible cooling Btuh19040Heating output Btuh64000 Latent cooling Btuh8160 Temperature rise °F60 Total cooling Btuh27200Actual air flow cfm1150 Actual air flow cfm907 Air flow factor cfm/Btuh0.033 Air flow factor cfm/Btuh0.067Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 1.00 2022-May-05 17:28:00 Rig ht-Su ite® U niv er sal 20 19 19 .0.13 RSU2 0477 Page 1 S:\High Country\Wrightsoft\SF9B14 Savannah.rup Calc = MJ8 House faces: NE SF9B14Job:AED Assessment Date:Entire House Vince ByramBy: SAVANNAH CPlan:Kartchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 Project Information Cody Puzey, Kartchner HomesFor: 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Design Conditions Location:CoolingHeatingIndoor: 7568Indoor temp era ture (°F)Idaho Falls, ID, US 1474Design TD (°F)ft4741Elevation: 5050Relative humidity (%)°N44Latitude: Outdoor:-31.557.0Moisture difference (gr/lb)CoolingHeating Infiltration:89-6Dry bul b (°F) )H(34-Da ily ra nge (°F) 60-We t bu lb (°F) 7.515.0Wind speed (mph) Test for Adequate Exposure Diversity Hourly Glazing Load Hourly Average AED limit Gl a z i n g l o a d ( B t u h ) Hour of Day 0 2,000 4,000 6,000 8,000 10,000 12,000 14,000 8 9 10 11 12 13 14 15 16 17 18 19 20 Maximum hourly glazing load exceeds average by 47.1%. House does not have adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 1549 Btuh (PFG - 1.3*AFG) Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-May-05 17:28:00Right-Su ite® U niv er sal 20 19 19 .0.13 RSU2 0477 Page 1S:\High Country\Wrightsoft\SF9B14 Savannah.rup Calc = MJ8 House faces: NE SF9B14Job:Right-J® W or ksheet Date:Entire House Vince ByramBy:SAVANNAH CPlan:Kartchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 1 Room name Entire House Room1 2 Exposed wall 314.7 ft 33.0 ft 3 Room height 8.0 dft 8.0 heat/coolft 4 Room dimensions ft18.0x15.0 5 Room area 2651.2 f t²270.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.814.81 0.470.47 616 416 1999 197 120 72 346 34 .GG 2 glazing, clr outr,0.3002 glazing, clr outr,0.300 nn 22.2022.20 10.2810.28 79 0 1754 812 48 0 1066 493 .GG 2 glazing, clr outr,0.3002 glazing, clr outr,0.300 nn 22.2022.20 10.2810.28 121 0 2695 1247 0 0 0 0 .WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.814.81 0.470.47 641 641 3085 304 0 0 0 0 1 1 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.814.81 0.470.47 616 472 2270 224 0 0 0 0 GG 2 glazing, clr outr,0.3002 glazing, clr outr,0.300 ss 22.2022.20 18.6018.60 77 0 1709 1432 0 0 0 0 GG 2 glazing, clr outr,0.3002 glazing, clr outr,0.300 ss 22.2022.20 18.6018.60 25 0 555 465 0 0 0 0 DD metalmetal 0.2900.290 ss 11.1011.10 5.365.36 42 42 466 225 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.814.81 0.470.47 644 501 2410 238 144 119 572 56 GG 2 glazing, clr outr,0.3002 glazing, clr outr,0.300 ww 22.2022.20 34.1434.14 66 0 1465 2254 25 0 555 854 GG 2 glazing, clr outr,0.3002 glazing, clr outr,0.300 ww 22.2022.20 34.1434.14 77 0 1709 2629 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.481.48 0.840.84 1531 1531 2266 1286 270 270 400 227 FF 21A-28c21A-28c 0.0220.022 --1.631.63 0.000.00 1183 1183 1926 0 0 0 0 0 FF 22A-cpm22A-cpm 1.1801.180 --87.3287.32 0.000.00 352 42 3707 0 0 0 0 0 6 c) AED excursion 1549 279 Envelope loss/gain 28017 12862 2939 1943 12 a)Infiltration 6769 686 710 72 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)34786 13548 3649 2015 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 34786 13548 3649 2015 15 Duct loads 0%0%0 0 -0%0%0 0 Total room load 34786 13548 3649 2015 Air required (cfm)Air required (cfm)1150 907 121 135 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-May-05 17:28:00Right-Su ite® U niv er sal 20 19 19 .0.13 RSU2 0477 Page 2S:\High Country\Wrightsoft\SF9B14 Savannah.rup Calc = MJ8 House faces: NE SF9B14Job:Right-J® W or ksheet Date:Entire House Vince ByramBy:SAVANNAH CPlan:Kartchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 1 Room name Room2 Room3 2 Exposed wall 9.0 ft 0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft12.0x9.0 ft6.0x9.0 5 Room area 108.0 f t²54.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.814.81 0.470.47 72 56 269 27 0 0 0 0 .GG 2 glazing, clr outr,0.3002 glazing, clr outr,0.300 nn 22.2022.20 10.2810.28 16 0 355 164 0 0 0 0 .GG 2 glazing, clr outr,0.3002 glazing, clr outr,0.300 nn 22.2022.20 10.2810.28 0 0 0 0 0 0 0 0 .WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.814.81 0.470.47 0 0 0 0 0 0 0 0 1 1 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.814.81 0.470.47 0 0 0 0 0 0 0 0 GG 2 glazing, clr outr,0.3002 glazing, clr outr,0.300 ss 22.2022.20 18.6018.60 0 0 0 0 0 0 0 0 GG 2 glazing, clr outr,0.3002 glazing, clr outr,0.300 ss 22.2022.20 18.6018.60 0 0 0 0 0 0 0 0 DD metalmetal 0.2900.290 ss 11.1011.10 5.365.36 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.814.81 0.470.47 0 0 0 0 0 0 0 0 GG 2 glazing, clr outr,0.3002 glazing, clr outr,0.300 ww 22.2022.20 34.1434.14 0 0 0 0 0 0 0 0 GG 2 glazing, clr outr,0.3002 glazing, clr outr,0.300 ww 22.2022.20 34.1434.14 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.481.48 0.840.84 108 108 160 91 54 54 80 45 FF 21A-28c21A-28c 0.0220.022 --1.631.63 0.000.00 0 0 0 0 0 0 0 0 FF 22A-cpm22A-cpm 1.1801.180 --87.3287.32 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -15 -2 Envelope loss/gain 784 267 80 43 12 a)Infiltration 194 20 0 0 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)978 286 80 43 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 978 286 80 43 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 978 286 80 43 Air required (cfm)Air required (cfm)32 19 3 3 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-May-05 17:28:00Right-Su ite® U niv er sal 20 19 19 .0.13 RSU2 0477 Page 3S:\High Country\Wrightsoft\SF9B14 Savannah.rup Calc = MJ8 House faces: NE SF9B14Job:Right-J® W or ksheet Date:Entire House Vince ByramBy:SAVANNAH CPlan:Kartchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 1 Room name Room4 Room5 2 Exposed wall 26.0 ft 7.0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft12.0x14.0 ft7.0x11.0 5 Room area 168.0 f t²77.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.814.81 0.470.47 112 97 467 46 0 0 0 0 .GG 2 glazing, clr outr,0.3002 glazing, clr outr,0.300 nn 22.2022.20 10.2810.28 15 0 333 154 0 0 0 0 .GG 2 glazing, clr outr,0.3002 glazing, clr outr,0.300 nn 22.2022.20 10.2810.28 0 0 0 0 0 0 0 0 .WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.814.81 0.470.47 96 96 462 46 56 56 269 27 1 1 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.814.81 0.470.47 0 0 0 0 0 0 0 0 GG 2 glazing, clr outr,0.3002 glazing, clr outr,0.300 ss 22.2022.20 18.6018.60 0 0 0 0 0 0 0 0 GG 2 glazing, clr outr,0.3002 glazing, clr outr,0.300 ss 22.2022.20 18.6018.60 0 0 0 0 0 0 0 0 DD metalmetal 0.2900.290 ss 11.1011.10 5.365.36 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.814.81 0.470.47 0 0 0 0 0 0 0 0 GG 2 glazing, clr outr,0.3002 glazing, clr outr,0.300 ww 22.2022.20 34.1434.14 0 0 0 0 0 0 0 0 GG 2 glazing, clr outr,0.3002 glazing, clr outr,0.300 ww 22.2022.20 34.1434.14 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.481.48 0.840.84 168 168 249 141 77 77 114 65 FF 21A-28c21A-28c 0.0220.022 --1.631.63 0.000.00 0 0 0 0 0 0 0 0 FF 22A-cpm22A-cpm 1.1801.180 --87.3287.32 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -22 -5 Envelope loss/gain 1510 365 383 86 12 a)Infiltration 559 57 151 15 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)2069 421 534 101 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 2069 421 534 101 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 2069 421 534 101 Air required (cfm)Air required (cfm)68 28 18 7 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-May-05 17:28:00Right-Su ite® U niv er sal 20 19 19 .0.13 RSU2 0477 Page 4S:\High Country\Wrightsoft\SF9B14 Savannah.rup Calc = MJ8 House faces: NE SF9B14Job:Right-J® W or ksheet Date:Entire House Vince ByramBy:SAVANNAH CPlan:Kartchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 1 Room name Room6 Room7 2 Exposed wall 5.0 ft 25.0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft5.0x11.0 ft14.0x11.0 5 Room area 55.0 f t²154.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.814.81 0.470.47 0 0 0 0 0 0 0 0 .GG 2 glazing, clr outr,0.3002 glazing, clr outr,0.300 nn 22.2022.20 10.2810.28 0 0 0 0 0 0 0 0 .GG 2 glazing, clr outr,0.3002 glazing, clr outr,0.300 nn 22.2022.20 10.2810.28 0 0 0 0 0 0 0 0 .WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.814.81 0.470.47 40 40 192 19 112 112 539 53 1 1 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.814.81 0.470.47 0 0 0 0 88 65 313 31 GG 2 glazing, clr outr,0.3002 glazing, clr outr,0.300 ss 22.2022.20 18.6018.60 0 0 0 0 23 0 511 428 GG 2 glazing, clr outr,0.3002 glazing, clr outr,0.300 ss 22.2022.20 18.6018.60 0 0 0 0 0 0 0 0 DD metalmetal 0.2900.290 ss 11.1011.10 5.365.36 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.814.81 0.470.47 0 0 0 0 0 0 0 0 GG 2 glazing, clr outr,0.3002 glazing, clr outr,0.300 ww 22.2022.20 34.1434.14 0 0 0 0 0 0 0 0 GG 2 glazing, clr outr,0.3002 glazing, clr outr,0.300 ww 22.2022.20 34.1434.14 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.481.48 0.840.84 55 55 81 46 154 154 228 129 FF 21A-28c21A-28c 0.0220.022 --1.631.63 0.000.00 0 0 0 0 0 0 0 0 FF 22A-cpm22A-cpm 1.1801.180 --87.3287.32 0.000.00 10 1 75 0 154 25 2183 0 6 c) AED excursion -4 96 Envelope loss/gain 349 61 3773 737 12 a)Infiltration 108 11 538 55 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)457 72 4311 792 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 457 72 4311 792 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 457 72 4311 792 Air required (cfm)Air required (cfm)15 5 143 53 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-May-05 17:28:00Right-Su ite® U niv er sal 20 19 19 .0.13 RSU2 0477 Page 5S:\High Country\Wrightsoft\SF9B14 Savannah.rup Calc = MJ8 House faces: NE SF9B14Job:Right-J® W or ksheet Date:Entire House Vince ByramBy:SAVANNAH CPlan:Kartchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 1 Room name Room8 Room9 2 Exposed wall 16.0 ft 35.0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft13.0x12.0 ft384.0x1.0 5 Room area 156.0 f t²384.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.814.81 0.470.47 0 0 0 0 0 0 0 0 .GG 2 glazing, clr outr,0.3002 glazing, clr outr,0.300 nn 22.2022.20 10.2810.28 0 0 0 0 0 0 0 0 .GG 2 glazing, clr outr,0.3002 glazing, clr outr,0.300 nn 22.2022.20 10.2810.28 0 0 0 0 0 0 0 0 .WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.814.81 0.470.47 16 16 77 8 0 0 0 0 1 1 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.814.81 0.470.47 96 73 351 35 120 89 428 42 GG 2 glazing, clr outr,0.3002 glazing, clr outr,0.300 ss 22.2022.20 18.6018.60 23 0 511 428 31 0 688 576 GG 2 glazing, clr outr,0.3002 glazing, clr outr,0.300 ss 22.2022.20 18.6018.60 0 0 0 0 0 0 0 0 DD metalmetal 0.2900.290 ss 11.1011.10 5.365.36 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.814.81 0.470.47 16 16 77 8 160 119 572 56 GG 2 glazing, clr outr,0.3002 glazing, clr outr,0.300 ww 22.2022.20 34.1434.14 0 0 0 0 41 0 910 1400 GG 2 glazing, clr outr,0.3002 glazing, clr outr,0.300 ww 22.2022.20 34.1434.14 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.481.48 0.840.84 156 156 231 131 384 384 568 323 FF 21A-28c21A-28c 0.0220.022 --1.631.63 0.000.00 0 0 0 0 0 0 0 0 FF 22A-cpm22A-cpm 1.1801.180 --87.3287.32 0.000.00 144 15 1290 0 20 2 159 0 6 c) AED excursion 99 380 Envelope loss/gain 2536 707 3326 2777 12 a)Infiltration 344 35 753 76 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)2880 742 4079 2854 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 17 9 45 24 14 Subtotal 2897 751 4125 2878 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 2897 751 4125 2878 Air required (cfm)Air required (cfm)96 50 136 193 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-May-05 17:28:00Right-Su ite® U niv er sal 20 19 19 .0.13 RSU2 0477 Page 6S:\High Country\Wrightsoft\SF9B14 Savannah.rup Calc = MJ8 House faces: NE SF9B14Job:Right-J® W or ksheet Date:Entire House Vince ByramBy:SAVANNAH CPlan:Kartchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 1 Room name Room10 Room11 2 Exposed wall 0 ft 24.0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft6.0x7.0 ft13.0x11.0 5 Room area 42.0 f t²143.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.814.81 0.470.47 0 0 0 0 0 0 0 0 .GG 2 glazing, clr outr,0.3002 glazing, clr outr,0.300 nn 22.2022.20 10.2810.28 0 0 0 0 0 0 0 0 .GG 2 glazing, clr outr,0.3002 glazing, clr outr,0.300 nn 22.2022.20 10.2810.28 0 0 0 0 0 0 0 0 .WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.814.81 0.470.47 0 0 0 0 0 0 0 0 1 1 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.814.81 0.470.47 0 0 0 0 88 63 303 30 GG 2 glazing, clr outr,0.3002 glazing, clr outr,0.300 ss 22.2022.20 18.6018.60 0 0 0 0 0 0 0 0 GG 2 glazing, clr outr,0.3002 glazing, clr outr,0.300 ss 22.2022.20 18.6018.60 0 0 0 0 25 0 555 465 DD metalmetal 0.2900.290 ss 11.1011.10 5.365.36 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.814.81 0.470.47 0 0 0 0 104 87 418 41 GG 2 glazing, clr outr,0.3002 glazing, clr outr,0.300 ww 22.2022.20 34.1434.14 0 0 0 0 0 0 0 0 GG 2 glazing, clr outr,0.3002 glazing, clr outr,0.300 ww 22.2022.20 34.1434.14 0 0 0 0 17 0 377 580 CC 16B-50ad16B-50ad 0.0200.020 --1.481.48 0.840.84 42 42 62 35 0 0 0 0 FF 21A-28c21A-28c 0.0220.022 --1.631.63 0.000.00 0 0 0 0 143 143 233 0 FF 22A-cpm22A-cpm 1.1801.180 --87.3287.32 0.000.00 24 0 0 0 0 0 0 0 6 c) AED excursion -2 91 Envelope loss/gain 62 34 1887 1207 12 a)Infiltration 0 0 516 52 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)62 34 2403 1259 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution -62 -34 0 0 14 Subtotal 0 0 2403 1259 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 0 0 2403 1259 Air required (cfm)Air required (cfm)0 0 79 84 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-May-05 17:28:00Right-Su ite® U niv er sal 20 19 19 .0.13 RSU2 0477 Page 7S:\High Country\Wrightsoft\SF9B14 Savannah.rup Calc = MJ8 House faces: NE SF9B14Job:Right-J® W or ksheet Date:Entire House Vince ByramBy:SAVANNAH CPlan:Kartchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 1 Room name Room12 Room13 2 Exposed wall 6.0 ft 10.0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft4.0x6.0 ft6.0x10.0 5 Room area 24.0 f t²60.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.814.81 0.470.47 0 0 0 0 0 0 0 0 .GG 2 glazing, clr outr,0.3002 glazing, clr outr,0.300 nn 22.2022.20 10.2810.28 0 0 0 0 0 0 0 0 .GG 2 glazing, clr outr,0.3002 glazing, clr outr,0.300 nn 22.2022.20 10.2810.28 0 0 0 0 0 0 0 0 .WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.814.81 0.470.47 0 0 0 0 0 0 0 0 1 1 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.814.81 0.470.47 48 48 231 23 80 59 284 28 GG 2 glazing, clr outr,0.3002 glazing, clr outr,0.300 ss 22.2022.20 18.6018.60 0 0 0 0 0 0 0 0 GG 2 glazing, clr outr,0.3002 glazing, clr outr,0.300 ss 22.2022.20 18.6018.60 0 0 0 0 0 0 0 0 DD metalmetal 0.2900.290 ss 11.1011.10 5.365.36 0 0 0 0 21 21 233 113 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.814.81 0.470.47 0 0 0 0 0 0 0 0 GG 2 glazing, clr outr,0.3002 glazing, clr outr,0.300 ww 22.2022.20 34.1434.14 0 0 0 0 0 0 0 0 GG 2 glazing, clr outr,0.3002 glazing, clr outr,0.300 ww 22.2022.20 34.1434.14 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.481.48 0.840.84 0 0 0 0 0 0 0 0 FF 21A-28c21A-28c 0.0220.022 --1.631.63 0.000.00 24 24 39 0 60 60 98 0 FF 22A-cpm22A-cpm 1.1801.180 --87.3287.32 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -2 -8 Envelope loss/gain 270 21 615 133 12 a)Infiltration 129 13 215 22 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)399 34 830 154 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution -399 -34 114 10 14 Subtotal 0 0 944 164 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 0 0 944 164 Air required (cfm)Air required (cfm)0 0 31 11 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-May-05 17:28:00Right-Su ite® U niv er sal 20 19 19 .0.13 RSU2 0477 Page 8S:\High Country\Wrightsoft\SF9B14 Savannah.rup Calc = MJ8 House faces: NE SF9B14Job:Right-J® W or ksheet Date:Entire House Vince ByramBy:SAVANNAH CPlan:Kartchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 1 Room name Room14 2 Exposed wall 118.7 ft 3 Room height 8.0 heat/coolft 4 Room dimensions ft956.2x1.0 5 Room area 956.2 f t² Ty Construction U-value Or HTM Area (f t²)Load Area Load number (Bt uh/f t²-°F)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W Frm wall, vnl ext, 3 0.065 n 4.81 0.47 312 191 917 90 .G 2 glazing, clr outr,0.300 n 22.20 10.28 0 0 0 0 .G 2 glazing, clr outr,0.300 n 22.20 10.28 121 0 2695 1247 .W Frm wall, vnl ext, 3 0.065 e 4.81 0.47 321 321 1546 152 1 1 W Frm wall, vnl ext, 3 0.065 s 4.81 0.47 96 75 361 36 G 2 glazing, clr outr,0.300 s 22.20 18.60 0 0 0 0 G 2 glazing, clr outr,0.300 s 22.20 18.60 0 0 0 0 D metal 0.290 s 11.10 5.36 21 21 233 113 W Frm wall, vnl ext, 3 0.065 w 4.81 0.47 220 160 770 76 G 2 glazing, clr outr,0.300 w 22.20 34.14 0 0 0 0 G 2 glazing, clr outr,0.300 w 22.20 34.14 60 0 1332 2049 C 16B-50ad 0.020 -1.48 0.84 63 63 93 53 F 21A-28c 0.022 -1.63 0.00 956 956 1557 0 F 22A-cpm 1.180 -87.32 0.00 0 0 0 0 6 c) AED excursion 665 Envelope loss/gain 9503 4481 12 a)Infiltration 2553 259 b)Room ventilation 0 0 13 Internal gains:Occupants @ 230 0 0 Appliances/other 0 Subtotal (lines 6 to 13)12055 4739 Less external load 0 0 Less transfer 0 0 Redistribution 285 24 14 Subtotal 12340 4764 15 Duct loads -0%0%0 0 Total room load 12340 4764 Air required (cfm)408 319 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-May-05 17:28:01 Rig ht-Su ite® U niv er sal 20 19 19 .0.13 RSU2 0477 Page 1 S:\High Country\Wrightsoft\SF9B14 Savannah.rup Calc = MJ8 House faces: NE SF9B14Job:Loads for Multiple Orientations Date:Entire House Vince ByramBy: SAVANNAH CPlan:Kartchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 Project Information Cody Puzey, Kartchner HomesFor: 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Design Conditions Location:CoolingHeatingIndoor: 7568Indoor temp era ture (°F)Idaho Falls, ID, US 1474Design TD (°F)ft4741Elevation: 5050Relative humidity (%)°N44Latitude: Outdoor:-31.557.0Moisture difference (gr/lb)CoolingHeating Infiltration:89-6Dry bul b (°F) )H(34-Da ily ra nge (°F) 60-We t bu lb (°F) 7.515.0Wind speed (mph) House North Northeast East Southeast South Southwest West Northwest Sensible Load (Btuh)17073 13595 15289 14917 14945 12908 15816 16675 Latent Load (Btuh)0 0 0 0 0 0 0 0 Total Load (Btuh)17073 13595 15289 14917 14945 12908 15816 16675 Heating AVF (cfm)1150 1150 1150 1150 1150 1150 1150 1150 Cooling AVF (cfm)907 907 907 907 907 907 907 907 Building Orientation Cooling Load To t a l C o o l i n g L o a d ( B t u h ) Direction House faces 0 5000 10000 15000 20000 N NE E SE S SW W NW House faces NortheastCurrent Orientation: House faces NorthHighest Cooling Load: Job #: SF9B14 Performed by Vince Byram for: Cody Puzey 3758 Yellowstones Hwy Idaho Falls, Id 83401 Phone: 208-529-2116 Kartchner 601 West 1700 South Logan, Utah 84321 Phone: 435-755-7080 Scale: 1 : 69 Page 1 Ri g ht-Su ite® U ni v ersal 201 9 19.0.13 RSU20477 2022-May-05 17:28:15 ...y\Wrightsoft\SF9B14 Savannah.rup N Main Room11 Room12 Room13 Room14 6" Mechanical Damper for Fresh Air 68 cfm 68 cfm 68 cfm 68 cfm 68 cfm 84 cfm 31 cfm 68 cfm 84 cfm 6 " 2-14x3.25 6 " 6 " 6 " 6 " 6 "12 x 812 " 6 "6 "6 " 439 cfm 3-14x3.25 6 "6 " 6 " 14x3.25 6 "2-14x3.25 6 " 14x3.25 6 " 6 " 14x3.25 6 " 6 " 6 " Job #: SF9B14 Performed by Vince Byram for: Cody Puzey 3758 Yellowstones Hwy Idaho Falls, Id 83401 Phone: 208-529-2116 Kartchner 601 West 1700 South Logan, Utah 84321 Phone: 435-755-7080 Scale: 1 : 69 Page 2 Ri g ht-Su i te® U ni v ersal 201 9 19.0.13 RSU20477 2022-May-05 17:28:15 ...y\Wrightsoft\SF9B14 Savannah.rup N 2nd floor Room1 Room2 Room3 Room4 Room5 Room6 Room7 Room8 Room9 Room10 67 cfm 113 cfm 253 cfm 34 cfm34 cfm 67 cfm 32 cfm 96 cfm 18 cfm 15 cfm 154 cfm 96 cfm 3 cfm 120 cfm 96 cfm 143 cfm 2022-May-05 17:28:02 Rig ht-Su ite® U niv er sal 20 19 19 .0.13 RSU2 0477 Page 1 S:\High Country\Wrightsoft\SF9B14 Savannah.rup Calc = MJ8 House faces: NE SF9B14Job:Duct System Summary Date:Entire House Vince ByramBy: SAVANNAH CPlan:Kartchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 Project Information Cody Puzey, Kartchner HomesFor: 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 CoolingHeating External static pressure in H2O0.70in H2O0.70 Pressure losses in H2O0.34in H2O0.34 Available static pressure in H2O0.36in H2O0.36 Supply / return available pressure 0.269 / 0.091 in H2O in H2O0.269 / 0.091 Lowest friction rate in/100ft0.079in/100ft0.079 Actual air flow cfm907cfm1150 Total effective length (TEL)ft453 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm)(cfm)FR (in)(in)Matl Ln (ft)Ln (ft)Trunk st2325.013.0ShMt0x06.00.07967601008cRoom1 st2325.013.0ShMt0x06.00.07967601008cRoom1-A st2325.013.0ShMt0x06.00.07984791259cRoom11 st2325.013.0ShMt0x06.00.0791131944hRoom13 st2325.013.0ShMt0x06.00.07953682057hRoom14 st1325.013.0ShMt0x06.00.07953682057hRoom14-A st2325.013.0ShMt0x06.00.07953682057hRoom14-B st2325.013.0ShMt0x06.00.07953682057hRoom14-C 325.013.0ShMt0x06.00.07953682057hRoom14-D st2325.013.0ShMt0x06.00.07953682057hRoom14-E st2325.013.0ShMt0x06.00.0791932978hRoom2 st2325.013.0ShMt0x06.00.0793343cRoom3 325.013.0ShMt0x06.00.07914341035hRoom4-A st2325.013.0ShMt0x06.00.07914341035hRoom4-B st1325.013.0ShMt0x06.00.079718534hRoom5 st1325.013.0ShMt0x06.00.079515457hRoom6 st1325.013.0ShMt0x06.00.079531434311hRoom7 st2325.013.0ShMt0x06.00.07950962897hRoom8 st2325.013.0ShMt0x06.00.07996681439cRoom9 st2325.013.0ShMt0x06.00.07996681439cRoom9-A 2022-May-05 17:28:02 Rig ht-Su ite® U niv er sal 20 19 19 .0.13 RSU2 0477 Page 2 S:\High Country\Wrightsoft\SF9B14 Savannah.rup Calc = MJ8 House faces: NE Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st2 Peak AVF 805 722 0.079 1024 12.0 0x0 ShtMetl st1 Peak AVF 243 118 0.079 365 8.5 12x8 ShtMetl Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in)(cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in)Matl Trunk rb5 0x 2530 108 115.0 0.079 401 8.6 2-3.25x14 2-10x18 SJSp rt1 rb6 0x 1200 117 115.0 0.079 380 6.5 3.25x14 10x9 SJSp rt1 rb4 0x 1050 113 115.0 0.079 359 6.4 3.25x14 10x9 SJSp rt1 rb1 0x 1530 154 115.0 0.079 244 7.2 2-3.25x14 2-10x18 SJSp rt1 rb3 0x 790 84 115.0 0.079 267 5.7 3.25x14 10x9 SJSp rt1 rb2 0x 4390 330 115.0 0.079 463 10.6 3-3.25x14 3-10x27 SJSp Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk rt1 Peak AVF 711 577 0.079 0 8.0 0x14 ShtMetl