HomeMy WebLinkAboutPLANS - 20-00356 - 1106 Greenside Loop - Bryant - New SFR-Reviewed-Approved.pdfAuthor Name Author Email Author Phone No.:
Larry Beesley Larry.Beesley@rexburg.org 208-372-2176
Description : 1106 Greenside Loop - Bryant New SFR
Address :
Record Type : New Single Family Residence
Document Filename : PLANS - 20-00356 - 1106 Greenside Loop - Bryant - New SFR.pdf
Comment Author Contact Information:
Corrections in the following table need to be applied before a permit can be issued
Review Report
Approved
# 20-00356
Page Reference Annotation
Type
Author : Department Status Page Review Comments Applicant Response Comments
A1, A2 Free text Larry Beesley : Building Open 1 Street Number
Displayed on House
A1, A2 Free text Larry Beesley : Building Open 1 Roof Ventilation as per R806
A1, A2 Free text Larry Beesley : Building Open 1 Ground Surface to Slope away from Foundation a minimum of
6" within first 10 ft.
A1, A2 Free text Larry Beesley : Building Open 1 SD
A1, A2 Free text Larry Beesley : Building Open 1 Rebar: 8' Wall-Horizontal & Vertical 24" O.C. with 2 in Top 12"
Rebar: 4' Wall-Horizontal & Vertical 24" O.C. with 1 in Top 6"
A1, A2 Free text Larry Beesley : Building Open 1 See engineering specks for details
A3, A4 Free text Larry Beesley : Building Open 2 Roof Trusses (designed according to R802.10.1) 35 # Snow and
90 mph winds (Local Conditions)
A5 Free text Larry Beesley : Building Open 3 12' green space and 5' city sidewalk with a 6" gravel base.
New Single Family Residence
The Great Room area is over the allowed size of 900 Sq. Ft. and the 35' x 25' allowed in the code for our seismic zone of D o. This area of the plan will need to be engineered. IRC
Table R602.10.1.3
Approval of plans does not constitute approval of variance from code
Powered by TCPDF (www.tcpdf.org)
Firefox about:blank
1 of 3 5/20/2020, 2:44 PM
Street Number
Displayed on House
Roof Ventilation as per
R806
Ground Surface to Slope away
from Foundation a minimum of
6" within first 10 ft.
SD
Rebar: 8' Wall-Horizontal & Vertical 24" O.C. with 2 in Top
12"
Rebar: 4' Wall-Horizontal & Vertical 24" O.C. with 1 in Top 6"See engineering specks for details
Firefox about:blank
2 of 3 5/20/2020, 2:44 PM0.19 ftRoof Trusses (designed
according to R802.10.1)
35 # Snow and 90 mph
winds (Local Conditions)
Firefox about:blank
3 of 3 5/20/2020, 2:44 PM
12' green space and 5' city
sidewalk with a 6" gravel
base.