HomeMy WebLinkAboutELECRICAL INSPECTION TICKET - 21-00426 - Red 8 Asian Cuisine and Sushi Bar - RemodelInspection Ticket Commercial Electrical Final Inspection on 04/25/2022: PASS Permit Number: 21-00426Permit Details Commercial - Remodel Permit Issued Date: 11/08/2021469 N 2nd E Red 8 Asian Cuisine and Sushi Bar - Remodel Inspection Details alex.owens@rexburg.org Inspected By: Alex Owens Commercial Electrical Final Inspection on 04/25/2022: PASS D ESCRIPTIO N CO M M EN TS STATUS Check for continuity of grounded conductors in multiwire branch circuits. 300.13(B) COMPLETED Check for adequate length of free conductors in boxes. Verify that boxes are installed at junction, splice, outlet, switch, and pull points.300.14, 300.15 COMPLETED Check conductor fill in raceways.300.17 COMPLETED Verify that raceway systems are complete prior to installation of conductors. 300.18(A) COMPLETED Verify that fire ratings have been restored at electrical penetrations.300.21 COMPLETED Verify that raceways and cables are secured to boxes.314.17(B) and (C) COMPLETED Check for closure of unused openings.314.17(A)COMPLETED Verify that boxes in walls and ceilings are flush with the finished surface or, if surfaces are noncombustible, within 1/4 in. of the finished surface.314.20 COMPLETED Check for excessive gaps between edges of boxes and plaster, plasterboard, or drywall surfaces.314.21 COMPLETED Verify that boxes are securely fastened and supported.314.23 COMPLETED Check for covers on boxes.314.25, 314.28(C)COMPLETED Check lighting outlet boxes for suitability.314.27(A) and (B) COMPLETED Verify that all boxes are accessible. 314.29 COMPLETED Verify that switches or receptacles in boxes have their plaster ears seated against the wall surface or the box.404.10(B), 406.4(A) and (B) COMPLETED Verify that switches and receptacles are used within their ratings.404.14, 406.2(A), 430.109 COMPLETED Page 1 of 2 (Continued) Permit Number: 21-00426 D ESCRIPTIO N CO MMEN TS STATUS Check that receptacles project from metal faceplates or are flush with nonmetallic faceplates and that the faceplates cover openings.406.4(D) COMPLETED Check receptacles for proper polarity and for grounding and bonding connections. 406.3, 250.146, 200.11 COMPLETED Verify that receptacle ratings and branch-circuit ratings are compatible. 210.21, 210.24 COMPLETED Approved for a Final and C.O.For remodeled area only, (lights of seating area and sushi bar only). Sushi bar was not considered a kitchen area since there is no cooking to be performed. COMPLETED Receptacles have correct polarity, grounding, no open neutrals, etc. 200.10(B) COMPLETED Verify that installations have been made in accordance with the instructions included in listing and labeling of materials and equipment. 90.7, 110.3(B) COMPLETED Verify that interrupting ratings are adequate for the conditions of the installation. 110.9 COMPLETED Verify that unused openings have been effectively closed.110.12(A), 408.7 COMPLETED Check wiring methods for spacing from edges of framing and for protection from nails and screws. 300.4(A), (B), (D), and (E) COMPLETED Check for continuity and completeness in metal raceways and enclosures. 300.10 COMPLETED Verify that wiring methods are securely fastened in place, supported independently of suspended ceilings, and not used as supports.300.11 and applicable Chapter 3 article(s) APPROVED Inspector Comments For remodeled area only, (lights of seating area and sushi bar only). Sushi bar was not considered a kitchen area since there is no cooking to be performed. Planning and Zoning Final Inspection - Lot Layout Plan Commercial Building Final Final Inspections still to be completed Please call hotline 208-372-2344 to schedule final inspections when ready Page 2 of 2